Version 2.82

Part Description

LP6617-7   US.doppler
Doppler ultrasound detects the shift in frequency of ultrasound signals reflected from moving objects. Conventional Doppler techniques assess the velocity of blood flow by measuring high-frequency, low-amplitude signals from small, fast-moving blood cells. PMID: 16534017 Source: Regenstrief LOINC , PMID: 16534017

LOINC Names Get Info

Fully-Specified Name
Multisection:Find:Pt:Head>Head vessels:Doc:US.doppler
Long Common Name
US.doppler Head vessels
Short Name
DOP Head ves

Part Model Get Info

  • Component
    Multisection
    LP33405-9
    • Analyte
      Multisection
      LP33405-9
      • Component Numerator
        Multisection
        LP33405-9
        • Component Numerator Core
          Multisection
          LP33405-9
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Find
    LP6813-2
  • Time
    Pt
    LP6960-1
    • Time Core
      Pt
      LP6960-1
    • Time Modifier
      NULL
       
  • System
    Head>Head vessels
    LP191604-0
    • System Core
      Head>Head vessels
      LP191604-0
    • Super System
      NULL
       
  • Scale
    Doc
    LP32888-7
  • Method
    US.doppler
    LP6617-7

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINC Name R/O/C Cardinality Example UCUM Units
81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0 History general O
Indent55115-0 Request (Radiology) O
Indent55111-9 Current imaging procedure descriptions Document O
Indent55114-3 Prior procedure descriptions O
Indent18834-2 Radiology Comparison study - observation O
Indent18782-3 Radiology Study observation (findings) R
Indent19005-8 Radiology - Impression O
Indent18783-1 Radiology Study recommendation O
Indent55110-1 Conclusions O
Indent55107-7 Addendum O
Indent18785-6 Radiology Reason for study O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55112-7 Summary O
Indent55113-5 Key images O

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINC Name R/O/C Cardinality Example UCUM Units
72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3 Radiology Study observation (findings) R
Indent55107-7 Addendum O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55110-1 Conclusions O
Indent55111-9 Current imaging procedure descriptions Document O
Indent11329-0 History general O
Indent55113-5 Key images O
Indent55114-3 Prior procedure descriptions O
Indent19005-8 Radiology - Impression O
Indent18834-2 Radiology Comparison study - observation O
Indent18785-6 Radiology Reason for study O
Indent18783-1 Radiology Study recommendation O
Indent55115-0 Request (Radiology) O
Indent55112-7 Summary O

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 1.0o
Last Updated
Version 2.61 (MIN)
Change Reason
The scale has been changed from "Nar" to "Doc" to fit with the CDA model.; Changed System from "Head vessels" to "Head>Vessels" for conformance with LOINC/RadLex unified model.; Jan 2016 Changed System from Head>Vessels to Head>Head vessels to clarify the imaging focus per the RadLex/LOINC Committee
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC Group Group Name
LG41824-0 Region imaged: Head

Language Variants Get Info

Tag Language Translation
el-GR Greek (Greece) Πολυτομική εξέταση:Εύρεση:Pt:Κεφαλή>Κεφαλικά αγγεία:Doc:Υπερηχογράφημα.doppler
Synonyms: (Πολυτομική εξέταση Doc Pt RAD Αγγεία Εύρεση ΗΠΑ Κεφαλή Κεφαλή>Κεφαλικά αγγεία Πολυτομική εξέταση Υπερηχογράφημα.doppler
es-AR Spanish (Argentina) proyecciones:hallazgo:punto en el tiempo:cabeza:Narrativo:ecografía.doppler
es-MX Spanish (Mexico) Multisección:Tipo:Punto temporal:Cabeza> Vasos de cabeza:Documento:US.doppler
it-IT Italian (Italy) Sezioni multiple:Osservazione:Pt:Testa>Vasi della testa:Doc:Eco.doppler
Synonyms: Eco Ecografia.doppler Multistrato Osservazione Punto nel tempo (episodio) Radiologia Vasi della testa
pt-BR Portuguese (Brazil) Seccionais:Achado:Pt:Vasos cerebrais:Nar:US.Doppler
Synonyms: Finding; Findings; Point in time; Random; Head ves; Skull; Brain; Intracranial; Cranium; Cranial; Narrative; Report; DOP; DUPLEX; Ultrasound; ULS; Sonogram; Sonography; Sonograph; Echography; RADIOLOGY; Imaging; Echoencephalogram; Echoencephalography; Transcranial
zh-CN Chinese (China) 多层:发现:时间点:头部>血管类:文档型:超声.多普勒
Synonyms: (多层(多平面、多切面、多断面、多截面、多剖面、多排) 一种超声检查,用于确定几个脑部结构的位置和大小,从而系统地检查脑部和脊髓可疑的软组织疾病。 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 多层(多平面、多切面、多断面、多截面、多剖面、多排);多排 大脑;头;头壳;头的;头盖;头盖的;头盖骨;头部的;头颅;头颅内;头颅内的;头骨;脑;脑壳;脑的;颅;颅侧;颅的;颅骨;颅骨内;颅骨内的 头部>血管;头部>血管类(血管、脉管类、脉管) 头部血管;头部脉管 头部血管超声多普勒检查 头部超声检查方法 头部超声波 头部超声波检查方法 心脏超声.多普勒 成像;放射医学;放射学;显像 时刻;随机;随意;瞬间 经过颅骨的 经颅 脑回波图 脑回波描记仪 脑回波描记仪术 血管(复数);脉管;脉管(复数);血管 超声检查方法;超声检查法;超声波;超声波检查方法;超声波检查法

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=24733-8