Tech Guide Mpi en
Tech Guide Mpi en
A Technologlsts Gulde
E
u
ro
pean Association of Nuclear Medic
in
e
2
Contributors
Wim van den Broek
Chairman EANM TC; Chief Technologist
Dept of Nuclear Medicine, University Medical
Centre
Nijmegen, The Netherlands
Alberto Cuocolo
MD
Dept of Biomorphological and Functional
Sciences
Federico II University, Naples, Italy
Adriana Ghilardi
Chief Technologist
Dept of Nuclear Medicine, Ospedali Riuniti,
Bergamo, Italy
Sue Huggett
Member of EANM TC Education Sub-Committee
Programme Coordinator for Nuclear Medicine
Technology
Dept of Radiography, City University, London,
United Kingdom
Rgis Lecoultre
Technologists Educator
HECVSant - flire TRM, Lausanne, Switzerland
Julie Martin
Director of Nuclear Medicine
Dept of Nuclear Medicine, Guys and St Thomas
Hospitals
London, United Kingdom
Giuseppe Medolago
MD
Dept of Nuclear Medicine, Ospedali Riuniti,
Bergamo, Italy
Jos Pires Jorge
Member of EANM TC Education Sub-Committee;
Technologists Educator
HECVSant - flire TRM, Lausanne, Switzerland
Audrey Taylor
Chief Technologist
Dept of Nuclear Medicine, Guys and St Thomas
Hospitals
London, United Kingdom
Under the auspices of the European Association of Nuclear Medicine
Technologist Committee Education Sub-Committee
E
A
N
M
3
Contents
Foreword 4
Wim van den Broek
Introduction 5
Sue Huggett
Chapter 1 Applications and Rationale of Myocardial Perfusion Imaging 713
Alberto Cuocolo
Chapter 2 Patient Preparation 1416
Julie Martin and Audrey Taylor
Chapter 3 Stress Protocols 1728
Adriana Ghilardi and Giuseppe Medolago
Chapter 4 Preparation and Use of Imaging Equipment 2935
Rgis Lecoultre and Jos Pires Jorge
Chapter 5 Imaging and Processing 3643
Julie Martin and Audrey Taylor
References 44
This booklet was sponsored by an educational grant from Bristol-Myers Squibb Medical Imaging.
The views expressed are those of the authors and not necessarily of Bristol-Myers Squibb Medical
Imaging.
4
Technologists have become an important
group within the EANM. Since its inception,
the Technologist Committee of the EANM has
been working to improve the professional
expertise of nuclear medicine technologists
(NMTs) in Europe.
Expertise is the keyword; NMTs professional
and practical expertise is essential to ensur-
ing an expert nuclear medicine examination.
The NMT must safeguard patients wellbeing,
ensure each examination is performed cor-
rectly, and maintain an operating procedure
that guarantees the quality of the results.
In 1998, a start was made with the publica-
tion of Competencies for the European NMT,
which was followed by Advanced Skills and
Responsibility Guidelines for the Senior NMT
and other publications, all promoting good
practice for NMTs.
Foreword
Wim van den Broek
In early 2004, the idea of providing a series
of booklets on imaging for technologists was
born. By September 2004, thanks to the hard
work of the EANM Technologist Sub-Commit-
tee on Education, it was possible to achieve
the frst goal in this series: this booklet on
myocardial perfusion scintigraphy (MPS) for
technologists.
I hope this booklet will fnd its way into the
pockets of technologists across Europe, and
prove a valuable aid in the daily work of NMTs
performing MPS scans.
Many thanks to all who have contributed to
this project, in particular the members of the
EANM Technologist Sub-Committee on Edu-
cation, and to Bristol-Myers Squibb Medical
Imaging for the sponsorship that made this
project possible.
Wim van den Broek
Chairman
EANM Technologist Committee
E
A
N
M
5
Introduction
Sue Huggett
In early 2004, the EANM Technologist Commit-
tee considered producing a booklet on myo-
cardial perfusion scintigraphy (MPS) for tech-
nologists. This was an exciting opportunity to
involve technologists from many European
countries in a collaborative efort to produce
a piece of work for and mainly by our own
profession. We wanted to provide informa-
tion for reference in a handy form that could
be kept nearby or even in the technologists
pocket when scanning.
Owing to the timescale, we decided that this
booklet should focus on traditional tomo-
graphic MPS and gated tomographic MPS
methods, with the possibility of further work
on PET methodologies to follow. Members
of the Education Sub-Committee drafted a
framework and set about fnding contribu-
tors for the various sections. It was gratifying
that everyone we approached was happy to
help.
Of course, all nuclear medicine studies need to
be performed well to obtain optimal diagnos-
tic information. MPS in particular encompass-
es many areas of technologist practice, from
stressing and setting up ECG traces to analysis
and display. As a result, the opportunities to
maintain and improve quality are sizeable.
We hope this booklet will prove useful in all
areas.
Knowledge of imaging theory can provide the
technologist with a deeper and more satis-
fying understanding of practical techniques,
improve decision-making, and allow the tech-
nologist to pass on accurate information to
patients, their carers, and other staf. Patient
care is always paramount, and being able to
explain why certain foods must be avoided
or why it is necessary to lie in awkward posi-
tions improves compliance and is satisfying
in its own right.
Protocols vary between departments, even
within the broader terms of the EANM Guide-
lines, and this booklet is not meant to supplant
these protocols but hopefully to supplement
and explain the rationales behind them. This
will hopefully lead to more thoughtful work-
ing practices. For example, both checking
for suitability and proper preparation before
a study can save time and reduce radiation
doses. Information from and about patients
can be incomplete or misleading, so under-
standing the importance of what they say
on arrival is vital if the technologist is to spot
potential problems early on.
In order to know when and how to apply
variations in the protocol for acquisition or
analysis, we must be aware of the rationales
behind certain strategies. For example, obese
patients attenuate more photons, so in such
cases it could be advisable to linger longer at
each angle or to use a diferent order flter if
total counts are low.
6
The same philosophy applies to equipment;
if you understand the consequences of any
suspicious QC results, you will know when to
pay closer attention to certain parameters. We
hope that this booklet can provide informa-
tion as and when it is needed so that the in-
tegration of theory and practice is facilitated
and encouraged.
The authors are indebted to a number of infor-
mation sources, not least local protocols, and
references have been given where original
authors were identifable.
We apologise if we have inadvertently made
uncredited use of material for which credit
should have been given.
E
A
N
M
7
Applications and Rationale
of Myocardial Perfusion Imaging
Alberto Cuocolo
During the past two decades, the clinical role
of nuclear medicine procedures in cardiology
has evolved signifcantly. Initially, the diagnos-
tic role of nuclear medicine in detecting myo-
cardial ischaemia in patients with suspected
coronary artery disease was emphasised. Sub-
sequently, myocardial perfusion imaging has
made signifcant advances in the determina-
tion of prognosis in patients with ischaemic
heart disease, preoperative risk assessment
for patients undergoing non-cardiac surgery,
and assessment of the efcacy of revasculari-
sation in patients undergoing coronary artery
bypass surgery or interventional procedures.
More recently, particular attention has been
focused on the ability of nuclear cardiology
to characterise myocardial tissue and to assess
myocardial viability in patients with ischaemic
left ventricular (LV) dysfunction.
Common clinical indications for an MPS
study
1. Diagnosis of coronary artery disease: pres-
ence, location (coronary territory), and extent
(number of vascular territories involved)
2. Risk assessment (prognosis) in patients: both
after myocardial infarction and preoperatively
for major surgery that may be a risk for coro-
nary events
3. Assessment of myocardial viability: diferen-
tiating ischaemia from scar, and predicting im-
provement of LV function after interventions
4. Monitoring of treatment efect after coro-
nary revascularisation procedures
1. Diagnosis of coronary artery disease
Myocardial perfusion imaging with exercise or
pharmacological stress testing is an accepted
technique for the detection and localisation of
coronary artery disease (1,2).
During exercise or pharmacological stress, the
vasodilating capacity of microcirculation is lim-
ited and obstruction in the epicardial coronary
arteries becomes physiologically important,
providing a mechanism for the non-invasive di-
agnosis of obstructive coronary artery disease.
Myocardial perfusion abnormalities detected
during either exercise or pharmacological
stress are due to diferential blood fow be-
tween normal and stenotic arteries.
The determination of these disparities is de-
pendent on the ability of diferent tracers to
refect the changes in increased blood fow
produced by the stressors.
All myocardial perfusion imaging agents avail-
able for clinical use have shown a linear rela-
tionship up to approximately twofold higher
than baseline. Beyond this level, there appears
to be a decrease in the uptake of most agents
in relation to blood fow. The plateau efect dif-
fers demonstrably between tracers. Compared
to resting blood fow, it should be assumed
that exercise will typically cause a two- to
threefold increase in myocardial blood fow,
8
while stress in response to pharmacological
agents will typically be accompanied by a
three- to eightfold increase.
Myocardial perfusion tracers available for
clinical use include thallium (Tl-201) and
technetium-99m (Tc-99m) labelled agents
(e.g. sestamibi and tetrofosmin). The relation-
ship between blood fow and the activities
of these tracers has been widely studied.
Blood fow and thallium activity show a lin-
ear relationship up to at least 3 ml/min/gm.
However, at approximately 3 ml/min/gm
there appears to be a plateau efect such
that further increases in blood fow do not
change thallium activity. The extraction frac-
tion of sestamibi is less than thallium. Data
from animal studies demonstrate a linear re-
lationship between blood fow and sestamibi
uptake, up to approximately 2 ml/min/gm.
Above this level, uptake is not linked to in-
creasing fow in a linear fashion. Similar data
are emerging for tetrofosmin, though this
tracer demonstrates a plateau during stress at
a lower blood fow level than does sestamibi.
Thus, thallium, sestamibi, and tetrofosmin all
exhibit a plateau efect that occurs above
the typical blood fow range for exercise or
most pharmacological stress. The Tc-99m la-
belled tracer with the best extraction fraction
(higher than thallium) is teboroxime, which
shows a linear correlation within the range
of pharmacological stress. However, the rapid
clearance of this tracer from the myocardium
has made this agent difcult to use clinically.
All these tracers have diferent kinetic char-
acteristics, which must be considered when
attempting to maximise their clinical applica-
tion in stress imaging. Moreover, it must be
remembered that in clinical imaging ideal
conditions do not always exist.
Despite the diferences in tracer kinetics,
comparative studies involving thallium and
Tc-99m labelled agents have failed to show
signifcant diferences. Several clinical stud-
ies have documented the clinical impact of
thallium imaging in the detection of coronary
artery disease. In particular, the sensitivity of
single-photon emission computed tomog-
raphy (SPECT) thallium imaging has been
reported to be approximately 90%, with a
relatively low specifcity of 60% to 70%. Since
their introduction, sestamibi and tetrofosmin
have been compared to thallium as the gold
standard in the identifcation of patients with
coronary artery disease. The reported respec-
tive average sensitivities and specifcities of
sestamibi and tetrofosmin in the identifca-
tion of coronary artery disease have been
very similar to those obtained with thallium
imaging. However, some studies have re-
ported that sestamibi and tetrofosmin might
underestimate the total extent of myocardial
ischaemia, relative to thallium imaging, in pa-
tients with coronary artery disease (3). On the
other hand, signifcant diferences regarding
the image quality have been reported in all
comparative studies performed. In particular,
images obtained using sestamibi or tetrofos-
E
A
N
M
9
Chapter 1: Applications and Rationale of Myocardial Perfusion Imaging Alberto Cuocolo
min are of superior quality to those obtained
with thallium and tend to show fewer soft tis-
sue attenuation artefacts. Better defnition of
the myocardium, endocardial and epicardial
borders, and perfusion defects has been ob-
served. In general, there is much less statistical
noise when using sestamibi and tetrofosmin,
and the myocardial-to-background ratios are
reportedly similar to those obtained with
thallium imaging. Moreover, the permissible
administered dose for Tc-99m labelled agents
is much larger than for thallium. This results in
an increased pixel count density for Tc-99m
labelled tomographic projection images and
permits the use of higher resolution flters dur-
ing reconstruction.
Modern nuclear cardiology imaging tech-
niques coupled with the development of Tc-
99m labelled perfusion tracers now permit
simultaneous myocardial perfusion and LV
function studies in a single test. The potential
advantages of simultaneous assessment of
myocardial perfusion and LV function have
recently been outlined (4). Gated imaging of
the perfused myocardium is a well-established
technique for this purpose, using a single in-
jection of a Tc-99m labelled perfusion tracer.
Recent data has demonstrated the impact and
clinical role of these studies in the diagnosis
of patients with suspected or known coronary
artery disease; the addition of functional in-
formation to perfusion data has been shown
to improve the detection of multivessel dis-
ease.
2. Risk assessment (prognosis) in patients
with coronary artery disease
Another key role of myocardial perfusion im-
aging is its ability to provide prognostic infor-
mation in patients following acute myocardial
infarction, in patients with chronic coronary
artery disease, and in patients scheduled for
major surgery (5). The utility of thallium scin-
tigraphy associated with exercise pharmaco-
logical stress testing for this purpose has been
widely documented. In particular, it has been
demonstrated that in patients without prior
myocardial infarction the number of reversible
thallium defects is the most important statis-
tically signifcant predictor of future cardiac
events. Moreover, the extent and severity of
thallium defects correlate with the occurrence
of cardiac events. Several studies have report-
ed similar results for the prognostic value of
thallium stress imaging, both after myocardial
infarction and in patients with suspected or
known coronary artery disease. The data from
these studies demonstrate that the extent of
perfusion abnormality found through SPECT
imaging is the single most important prog-
nostic predictor.
More recently, the prognostic value of Tc-99m
labelled myocardial perfusion agents has been
demonstrated with data comparable to that
of thallium imaging. In particular, the extent
of hypoperfusion in post-stress sestamibi im-
ages can be factored into the decision-mak-
ing process when deciding whether to select
medical therapy or revascularisation. Patients
l0
with mild reversible perfusion defects who
are judged to be at low or intermediate risk
can usually be treated medically, whereas pa-
tients with high risk SPECT reversibility results
are candidates for further invasive strategies.
Moreover, a strategy incorporating stress MPS
is also cost-efective. A large study in stable
angina patients referred for stress myocardial
perfusion SPECT imaging or direct catheterisa-
tion revealed that costs were higher for the
initial invasive strategy in clinical subsets with
low, intermediate, or high pre-test likelihoods
of disease. Diagnostic follow-up costs of care
were 30-41% higher for patients undergoing
direct catheterisation, without any reduction in
mortality or infarction compared with patients
having stress perfusion imaging as the initial
test for coronary artery disease detection.
3. Assessment of myocardial viability
It has been demonstrated that a third of pa-
tients with chronic coronary artery disease
and LV dysfunction have the potential for
signifcant improvement in ventricular func-
tion after myocardial revascularisation. These
fndings have several implications. Firstly,
there is the important relationship between
LV function and patients survival. In recent
years, numerous studies have demonstrated
that nuclear cardiology techniques involving
SPECT provide important viability information
in patients with coronary artery disease and
impaired ventricular function (6-12). Although
positron emission tomography (PET) remains
the most accurate technique for the detec-
tion of viable myocardium, diferent thallium
protocols have been used in previous studies
to assess myocardial viability in patients with
previous myocardial infarction and chronic LV
dysfunction. In particular, if the clinical issue
to be addressed is the viability of one or more
ventricular regions with systolic dysfunction
and not whether there is also inducible isch-
aemia, rest-redistribution thallium imaging
can yield useful viability data. In particular,
it has been demonstrated that quantitative
analysis of rest-redistribution images predicts
recovery of regional LV function and compares
favourably to the results of both thallium re-
injection imaging and metabolic PET imaging
(7). Optimal interpretation of thallium imaging
for the detection of myocardial viability can be
accomplished by measuring regional tracer
uptake and by selecting the most appropri-
ate cut-of to diferentiate reversible from ir-
reversible LV dysfunction (8-10). Furthermore,
sestamibi and tetrofosmin showed similar re-
sults to those of thallium scintigraphy in the
identifcation of viable myocardium (8).
A quantitative analysis of tracer content as well
as the administration of nitroglycerin prior to
tracer injection increases the overall accuracy
of Tc-99m labelled agents for identifying vi-
able myocardium. Recent data indicate that
in patients with chronic myocardial infarction
and impaired LV function on nitrate treatment,
quantitative analysis of resting thallium and
sestamibi regional activities comparably pre-
dict recovery of regional and global ventricular
E
A
N
M
ll
Chapter 1: Applications and Rationale of Myocardial Perfusion Imaging Alberto Cuocolo
function following revascularisation proce-
dures (11). Nitroglycerin most likely enhances
myocardial viability detection by increasing
coronary collateral fow, decreasing pre-load
and after-load, and direct vasodilatation of
stenotic segments in coronary arteries (12-
14). These physiological efects in combina-
tion may enhance the delivery of myocardial
perfusion agents to regions of myocardium
supplied by severely stenotic vessels.
In the assessment of myocardial viability, phar-
macological stress testing in combination with
wall motion analysis via gated images of the
perfused myocardium has been used (15). Al-
though the recovery of regional function after
revascularisation has generally been regarded
as the gold standard for detecting myocardial
viability, the clinical outcome after revasculari-
sation is a better and more valuable end-point.
The criteria for viability determination with re-
spect to its true clinical impact should be the
prediction of short- and long-term outcomes
such as cardiovascular mortality and recurrent
myocardial infarction (16). It should be kept
in mind that preserved myocardial perfusion
tracer uptake in zones of asynergy may have
a sub-optimal value for positive prediction of
improved segmental function after revascu-
larisation. However, it appears to predict a high
cardiac death and infarction rate with medi-
cal therapy and identifes a group of patients
with hibernating myocardium who would be
predicted to have an excellent outcome after
revascularisation. It has been demonstrated
that the amount of dysfunctional myocardi-
um with preserved thallium uptake provides
independent prognostic information that is
incremental to that obtained from clinical,
functional, and angiographic data in patients
with chronic ischaemic LV dysfunction. In
particular, patients with a substantial amount
(>30% of the total left ventricle) of dysfunc-
tional myocardium with preserved tracer
activity exhibited the greatest LV functional
beneft after successful revascularisation (17).
Moreover, patients with more than 50% viable
myocardium represented a subgroup at high-
risk of cardiac death in whom successful revas-
cularisation improved survival (17). Altogether
these observations seem to lend further sup-
port to the choice of coronary revascularisa-
tion in patients with evidence of a substantial
amount of dysfunctional myocardium with
preserved myocardial perfusion tracer activ-
ity. Thus, it appears that the assessment of
myocardial viability should be a mandatory
step in clinical decision-making for patients
with reduced global and regional LV systolic
function, to better predict the potential value
of revascularisation in improving functional
status and survival.
4. Monitoring of treatment efect after
coronary revascularisation procedures
The use of exercise or pharmacological myo-
cardial perfusion imaging in the assessment of
interventions in chronic ischaemic heart dis-
ease is indicated for the evaluation of resteno-
sis after percutaneous transluminal coronary
l2
angioplasty (PTCA) in symptomatic patients,
and in the assessment of ischaemia in symp-
tomatic patients after coronary artery bypass
grafting (CABG). Radionuclide techniques are
also indicated in the assessment of selected
asymptomatic patients after PTCA or CABG,
such as those with an abnormal electrocardio-
graphic response to exercise and those with
rest electrocardiographic changes precluding
identifcation of ischaemia during exercise.
SPECT exercise imaging is an excellent tool
for the detection of restenosis and disease
progression after PTCA after both one and
multivessel angioplasty, and in complete and
partial revascularisation. Hecht et al (18), study-
ing exercise tomographic thallium imaging in
the detection of restenosis after PTCA, showed
sensitivity of 93% for scintigraphic studies and
52% for exercise electrocardiographic studies,
specifcity of 77% vs 64%, and accuracy of 86%
vs 57%, respectively. Moreover, it has been
demonstrated that, after PTCA, sensitivity and
accuracy of exercise electrocardiography in
the detection of restenosis were signifcantly
less than those of SPECT imaging for patients
with silent or symptomatic ischaemia (19).
Patients with less typical symptoms and in-
termediate probability of restenosis can be
accurately assessed for this PTCA complication
by myocardial perfusion imaging studies. In
the patients with recurrent atypical symptoms,
stress perfusion imaging should be performed
soon after the onset of symptoms in order to
determine whether persistent myocardial
ischaemia is the cause of chest pain. Myocar-
dial imaging studies ofer several advantages
over stress electrocardiography, particularly
in patients with an abnormal resting electro-
cardiogram, multivessel coronary disease, or a
limitation to exercise stress testing. After PTCA,
nuclear cardiac imaging procedures are not
generally recommended in the absence of
recurrent symptoms, particularly since im-
aging abnormalities would not likely result
in either a changed therapeutic regimen or
repeat revascularisation. However, recent
data demonstrate that extent and severity
of myocardial ischaemia found via exercise
SPECT performed between 12 and 18 months
after percutaneous coronary intervention (PCI)
predict cardiac events during long-term fol-
low-up in both symptomatic and symptom-
free patients (20).
Exercise scintigraphy after CABG demonstrates
improved regional myocardial perfusion
in most patients. After CABG, the New York
Heart Associations functional class improved
signifcantly. Early (less than 3 months) post-
CABG, myocardial imaging may be useful for
the detection of perioperative infarction, or if
early graft closure with recurrence of angina
symptoms is suspected. Beyond 3 months,
and following the recovery of hibernation
efects, non-invasive cardiac imaging is use-
ful for detecting asymptomatic graft attrition
and the recurrence of myocardial ischaemia.
However, this approach cannot be routinely
recommended in all patients who undergo
E
A
N
M
l3
Chapter 1: Applications and Rationale of Myocardial Perfusion Imaging Alberto Cuocolo
CABG because it would not be cost-efective
to screen this large population in the 1 to 2
years following CABG surgery.
Contraindications
Myocardial perfusion imaging is non-invasive
- the complication rate of dynamic exercise
and pharmacological stress tests is low and
well established (at most 0.01% deaths and
0.02% morbidity) (21-24). Therefore, except in
patients with unstable heart disease or other
contraindications to stress, the risk is not con-
sidered signifcant.
l4
Patient Preparation
Julie Martin and Audrey Taylor
Patient identifcation
To minimise the risk of a misadministration, it
is necessary to:
establish the patients full name and other
relevant details prior to administration of
any drug or radiopharmaceutical
corroborate this data with information
provided on the diagnostic test referral
If the information on the referral form does not
match the information given from the identif-
cation process, then the radiopharmaceutical/
drug should not be administered to the pa-
tient. This should be explained to the patient
and clarifcation sought as soon as possible by
contacting the referral source.
The patient/parent/guardian/escort should
be asked the following questions and the in-
formation checked against their request form
and ward wristband if an inpatient.
Please can you tell me you/your patients
full name. - check any spellings as
appropriate, e.g. Steven vs Stephen
date of birth.
address.
A minimum of TWO corroborative details
should be asked and confrmed as correct.
The following information should be checked
with the patient/parent/guardian/escort where
appropriate.
Referring Clinician/GP/Hospital
E
A
N
M
l5
Patients with communication difculties
Ideally, patients who for any reason are un-
able to identify themselves should wear an
identifcation wristband.
Hearing difculties - Use written questions
and ask the patient to supply the infor-
mation verbally or write their responses
down.
Speech difculties - Ask the patient to
write down their name, date of birth,
address, and other relevant details.
Language difculties - If an accompany-
ing person is unable to interpret the
questions, then the study should be
rescheduled to a time when a member of
staf/relative/interpreter with the appro-
priate language skills will be available.
Unconscious patient - Check the patients
ID wristband for the correct name and
date of birth. If no wristband is attached,
ask the nurse looking after the patient to
positively confrm the patients ID.
Confused patient - If an inpatient, check
the patients ID wristband for the correct
name and date of birth. If no wristband is
attached, ask the nurse looking after the
patient to positively confrm the patients
ID. If an outpatient, ask the person accom-
panying the patient to positively confrm
the patients ID.
If a relative/friend/interpreter provides
information regarding the patients name,
E
A
N
M
25
zymatic degradation in myocardial cells and
vascular smooth cells (the T1/2 of exogenously
infused Adenosine is about 10 sec).
By directly stimulating A2 purine receptors in
the heart, endogene and exogene Adenosine
has an important role in the natural regulation
of coronary fow (vasodilatation) and cardiac
demand (lowering BP). By stimulating A1 pu-
rine receptors in SA and AV node, it inhibits
norepinephrine release from sympathetic
nerve endings, reduces AV node conduction
velocity, and has negative inotropic and chro-
notropic efects.
Although both Dipyridamole and Adenosine
exhibit similar physiological efects on coro-
nary and systemic circulation, the vasodila-
tor efect of Dipyridamole is more prolonged
(up to 20-40 min) than that of Adenosine. In
contrast, the regional and systemic vascular ef-
fects of Adenosine appear earlier (within 20-30
sec) and quickly disappear after discontinua-
tion of the infusion (T1/2 in plasma is about
15 sec). Maximal efect has been observed
invasively after 60 sec and continues as long
as the drug is infused. These metabolic char-
acteristics explain the lesser rate of side efects
for Adenosine compared to Dipyridamole (see
Table 3).
a) Protocol
Adenosine is infused over a 4-6 min period at a
dose of 140 g/kg/min. Radiotracer is injected
during the 5th or 6th minute of the infusion.
Many laboratories use the 2 plus 2 Adenosine
protocol, which is very convenient, efective,
and well tolerated. In this protocol, the radio-
tracer is injected after 2 min of infusion, and
the infusion then continues for an additional 2
min to clear the tracer from the blood.
In some laboratories, Adenosine infusion is
combined with handgrip exercise to reduce
background activity of the tracer in the ab-
dominal viscera. In some laboratories, at the
end of Adenosine infusion and after the i.v. ad-
ministration of the radiotracer, the intravenous
antidote Aminophylline is also administered
in order to rapidly reverse any undesirable
Adenosine-associated side efects.
b) Drug interactions (see Table 1)
Adenosine testing is the protocol of choice
in patients with signifcant arrhythmias or a
psychiatric history. Furthermore, Adenosine
testing is safe for stress testing soon after
acute MI.
c) Safety and risks
The risks associated with this procedure are de-
termined by the clinical characteristics of the
patient referred for the procedure. It should be
undertaken under the supervision of a physi-
cian properly trained to perform such a test;
any side efects, though often slightly more
severe and harder to control than with other
stress agents, can be rapidly reversed with the
intravenous antidote Aminophylline.
Chapter 3: Stress Protocols Adriana Ghilardi and Giuseppe Medolago
26
d) Absolute and relative contraindications to
Adenosine testing
bronchospasm
drug intolerance
30
technologist to a progressive deterioration of
the equipment.
On cameras that have interchangeable unifor-
mity correction maps, it is vital that the one
being used is accurate, up-to-date and for the
correct nuclide.
c) Daily gamma camera sensitivity
measurement
A practical means of measuring sensitivity is to
record the time needed to acquire the food
feld using the known activity. This should not
vary by more than a few percent from one
day to another.
d) Weekly linearity and resolution
assessment
Linearity and resolution should be assessed
weekly. This may be done by using transmis-
sion phantoms.
e) Weekly centre of rotation calibration
The centre of rotation (COR) measurement
determines the ofset between the axis of
rotation of the camera and the centre of the
matrix used for reconstruction, as these do not
automatically correspond.
The calibration of the centre of rotation is
made using a reconstruction of a tomographic
acquisition of a point source placed slightly
ofset from the mechanical centre of the rota-
tion of the camera. A sinogram is formed from
the projections and used to ft the maximum
count locations to a sine wave. Deviations be-
tween the actual and ftted curves should not
exceed 0.5 pixels.
f ) Quarterly multipurpose SPECT phantom
evaluation
Multipurpose plastic phantoms flled with a
radioactive solution approximate realistic con-
ditions of clinical scattering and attenuation.
The multipurpose phantom includes remov-
able cold rod sections and spheres simulating
cold lesions. The main purpose of imaging this
phantom is to determine the SPECT systems
limits of resolution. It is recommended that the
phantom be flled with 750-1000 MBq of Tc-99m
and the data acquired with an energy setting of
140 keV, a 20% energy window and a 128 x 128
pixel matrix for 128 projections over 360.
Collimator
In myocardial imaging the current tracers are
Tl-201 and Tc-99m labelled agents. The choice
of a collimator for a given study is determined
mainly by tracer activity. This infuences the
statistical noise content of the projection im-
ages and the spatial resolution. The number
of counts must be maximised, possibly at the
expense of some resolution.
Collimators vary in terms of the relative length
and width of the holes. The longer the hole,
the better the spatial resolution obtained but
the lower the count sensitivity. Conversely, a
larger hole gives better count sensitivity but
with a loss of spatial resolution.
E
A
N
M
3l
When using thallium, owing to the limited
dose and the long half-life of this isotope, the
count sensitivity will be greatly reduced. Tra-
ditionally, a low-energy general purpose col-
limator is recommended for use with Tl-201.
For Tc-99m imaging, count sensitivity is no
longer a major limitation so a high-resolution
collimator is recommended.
In myocardial SPECT imaging, however, the
major problem is the reduced spatial reso-
lution that occurs if the source-to-detector
distance is lengthened by the anatomical
situation of heart. Nevertheless, the resolu-
tion of an HR collimator decreases less with
distance from the source than does that of
a GP collimator. Although the choice of col-
limator is crucial, we should bear in mind that
other technical aspects play an important role
in determining the optimal spatial resolution;
these include the matrix size, the number of
angles and the time per view.
Matrix used and zoom factor
The goal of SPECT is to ascertain the distribu-
tion of injected activity in the patients body,
and in particular in the heart. The images (or
projections from the angles around the pa-
tient) create multiple raw data sets. Each of
these is electronically stored so that later on
they can be processed and their information
extracted. Each matrix contains the repre-
sentation of the data in one projection. It is
characterised by the number of pixels, each
pixel representing part of the object. Pixels
are square and typically organised in arrays of
64 x 64 or 128 x 128.
a) Matrix
The choice of matrix is dependent on four
factors:
i. Resolution:
The chosen matrix should not degrade the in-
trinsic resolution of the object. The commonly
accepted rule for SPECT (1) is that the pixel size
should be one third of the FWHM resolution of
the organ, which will depend on its distance
from the camera face. Spatial resolution of a
SPECT system is of the order of 18-25 mm at
the centre of rotation (2). Thus a pixel size of
6-8 mm is sufcient.
ii. Noise:
This is caused by the statistical fuctuations of
radioactive decay. Noise decreases with the
total number of counts, and if the matrix size is
doubled (to 128 instead of 64), the number of
counts per pixel is reduced by a factor of four.
128 x 128 matrices produce approximately
three times more noise in the image after re-
construction than do 64 x 64 matrices (3).
iii. Data size:
Of course, if there are four times more pixels
in each projection (128 versus 64), four times
more computer memory is needed for raw
data and approximately eight times more for
all processing. The processing time will also
increase. All new generation computers have
Chapter 4: Preparation and Use of Imaging Equipment Rgis Lecoultre and Jos Pires Jorge
32
more memory and resources for data calcula-
tion, but may take some time to come onto
the nuclear medicine market.
iv. Software:
Sometimes, set protocols restrict the software
options available to the technologist. This re-
striction may be needed to ensure that re-
sults can be compared with reference studies
or databases. It is very important to ensure
reproducibility in this way before setting up
individual acquisitions. The reconstruction
processing cannot replace information lost
in the acquisition.
b) Zoom
The pixel size is dependent on the camera FOV
(feld of view). When a zoom factor of 1.0 is
used, the pixel size (mm) is the UFOV (mm)
divided by the number of pixels in one line.
When a zoom factor is used, the number of
pixels per line should frst be multiplied by this
factor; the FOV should then be divided by the
result of this multiplication.
Example:
Acquisition with matrix 64, zoom 1.0 and
UFOV 400mm:
Pixel size (mm) = 400/64 = 6.25 mm
Same acquisition with a zoom factor of 1.4:
Pixel size (mm) = 400/(1.4 x 64) = 4.46 mm
c) Preferred orbits
Either circular or elliptical orbits can be used in
Figure 2a Figure 2b
cardiac SPECT imaging (Fig 2). A circular orbit
(a) is defned by a fxed distance from the axis
of rotation to the centre of the camera sur-
face for all angles. Elliptical orbits (b) follow
the body outline more closely.
With a circular orbit, the camera is distant from
the heart at some angles, causing a reduction
of spatial resolution in these projections. This
will reduce the resolution of the reconstructed
images.
With an elliptical orbit, spatial resolution is
improved as the camera passes closer to the
heart at all angles. Nevertheless, the distance
from the heart to the detector varies more sig-
nifcantly with an elliptical orbit than a circular
orbit. This may generate artifacts that simulate
perfusion defects when reconstructing using
fltered back projection.
Programmes that allow the camera to learn
and closely follow the contours of the body
are available and improve resolution, although
this is at the expense of computing power to
modify the data before reconstruction.
E
A
N
M
33
The loss of spatial resolution with a circular
orbit must be ofset against the potential ar-
tifacts that may be generated by an elliptical
or contoured orbit.
When selecting an orbit in cardiac SPECT im-
aging, it is most important to choose one that
does not truncate or clip the heart. This should
be checked after the acquisition while the pa-
tient is still available so that the acquisition can
be repeated if necessary.
ECG Gating
a) The ECG
The principal of the electrocardiogram is that
the electrical activity of the heart is detectable
on the bodys surface via electrical potential
diferences between sites. These diferences
can be recorded with electrodes coupled to
an electrocardiograph machine.
The ECG sequence:
Excitation of the atrium begins in the region
of the sino-atrial node (SN). One positively
charged electric wave goes through both atria
(depolarisation). This is represented by the P
wave on the ECG, and causes contractions. The
electric stimulation then reaches the atrioven-
tricular knot (AV) and, after a short stop whilst
the ventricles fll, progresses along the bundle
of His and Purkinje fbres. This step in ventricle
stimulation is seen in the QRS complex. After
a 1 sec pause, the ventricles repolarise (this is
visible as the T wave). The repolarisation of the
atria occurs at the same time as the QRS waves
and is therefore not visible on the ECG.
P Wave
T Wave
RR Interval
R Wave
S Wave
Q Wave
Example of an ECG (Figure 3)
Chapter 4: Preparation and Use of Imaging Equipment Rgis Lecoultre and Jos Pires Jorge
34
b) Acquisition
For gating, only the contraction signal is need-
ed and the R wave (the biggest signal from the
QRS complex) is used (Fig 4).
The three lead ECG is not for medical diagnosis
but for acquisition synchronisation. It provides
the most distinct R signal when the patient is
in the right position for acquisition.
Positive or negative signals can be used
equally but, if required, the inversion can be
done easily by changing over the two cables.
If necessary, the signal can be amplifed elec-
tronically on the ECG machine.
For a reliable trace, it is best to fx an electrode
onto each shoulder (frst moving the arm into
the acquisition position) and a third one onto
the abdomen, right lateral. Its best to fx this
lead on the righthand side as most acquisi-
tions are done with a 180 rotation over the
lefthand side of the patient.
It is possible to defne between 8 and 32 im-
ages per cardiac cycle, depending on how
much information is wanted on ventricular
wall motion. Two issues afect this choice:
i. The total counts and hence noise:
When the number of images is increased in
order to reach a given number of counts per
frame, the total acquisition time is extended.
ii. The data volume:
If one acquisition is considered, every division
of the cardiac cycle multiplies the data volume
(or the number of frames) by the same factor.
This is why 8 or 16 images per cycle are usually
used for SPECT. Each image of the cycle can
be called a bin.
c) Artifacts
The greatest source of artifacts during gated
acquisition is a changing HR. If any cycles difer
signifcantly in length then the information in
the total image will not be representative of
the same stage of contraction in each cycle,
but will instead be a mixture. Each image in
one gated cycle is written initially to the bufer.
If the length of its cardiac cycle is subsequently
found to be more than 10% of a preset value
based on prior observation of the patients
heartbeat, this cycle should be rejected from
the fnal sum.
It may be impossible to do gated acquisitions
on a patient who has a very unstable HR.
HR changes could be due to physical stress; if
the patient has come directly from the exer-
cise bicycle or has run along the corridor, their
HR will decrease after a few minutes, and the
window will have been wrongly set. Another
explanation of this problem is psychological
stress or anxiety. Conversely, if the patients HR
increases over time, it may be that the patient
is either becoming impatient or in an uncom-
fortable or painful position.
E
A
N
M
35
In some systems it is possible to exceed the defned time per projection in order to com-
plete cardiac cycles that were not in the acceptance window. We speak of an efective
acquisition time per projection. This is a good solution but the window defnition should
be good.
Gating via an ECG signal (Figure 4)
Chapter 4: Preparation and Use of Imaging Equipment Rgis Lecoultre and Jos Pires Jorge
36
T
h
a
l
l
i
u
m
T
c
-
9
9
m
s
e
s
t
a
m
i
b
i
T
c
-
9
9
m
t
e
t
r
o
f
o
s
m
i
n
P
h
o
t
o
p
e
a
k
e
n
e
r
g
y
(
k
e
V
)
6
-
8
0
(
9
8
%
)
1
3
5
(
2
%
)
1
6
7
(
8
%
)
1
4
0
1
4
0
M
o
r
e
s
c
a
t
t
e
r
(
w
o
r
s
e
r
e
s
o
l
u
t
i
o
n
)
M
o
r
e
a
t
t
e
n
u
a
t
i
o
n
O
p
t
i
m
a
l
f
o
r
g
a
m
m
a
c
a
m
e
r
a
(
b
e
t
t
e
r
r
e
s
o
l
u
t
i
o
n
)
L
e
s
s
a
t
t
e
n
u
a
t
i
o
n
O
p
t
i
m
a
l
f
o
r
g
a
m
m
a
c
a
m
e
r
a
(
b
e
t
t
e
r
r
e
s
o
l
u
t
i
o
n
)
L
e
s
s
a
t
t
e
n
u
a
t
i
o
n
H
a
l
f
-
l
i
f
e
(
h
o
u
r
s
)
7
3
.
1
6
6
C
y
c
l
o
t
r
o
n
p
r
o
d
u
c
t
t
o
b
e
o
r
d
e
r
e
d
R
e
a
d
y
f
o
r
u
s
e
A
l
w
a
y
s
a
v
a
i
l
a
b
l
e
(
2
4
m
o
n
t
h
s
s
h
e
l
f
l
i
f
e
a
t
r
o
o
m
t
e
m
p
e
r
a
t
u
r
e
)
P
r
e
p
a
r
a
t
i
o
n
2
0
m
i
n
(
i
n
c
l
u
d
i
n
g
1
0
m
i
n
b
o
i
l
i
n
g
)
A
l
w
a
y
s
a
v
a
i
l
a
b
l
e
(
6
m
o
n
t
h
s
s
h
e
l
f
l
i
f
e
a
t
2
-
8
C
)
P
r
e
p
a
r
a
t
i
o
n
1
5
m
i
n
E
f
e
c
t
i
v
e
d
o
s
e
a
d
u
l
t
(
S
v
/
M
B
q
)
2
3
1
S
t
r
e
s
s
:
7
.
4
R
e
s
t
:
8
.
5
S
t
r
e
s
s
:
6
R
e
s
t
:
6
.
8
H
i
g
h
e
r
d
o
s
i
m
e
t
r
y
(
f
o
r
t
e
s
t
e
s
3
0
x
h
i
g
h
e
r
t
h
a
n
w
i
t
h
T
c
t
r
a
c
e
r
s
)
F
a
v
o
u
r
a
b
l
e
d
o
s
i
m
e
t
r
y
(
a
l
l
o
w
s
h
i
g
h
e
r
d
o
s
e
)
F
a
v
o
u
r
a
b
l
e
d
o
s
i
m
e
t
r
y
(
a
l
l
o
w
s
h
i
g
h
e
r
d
o
s
e
)
E
x
t
r
a
c
t
i
o
n
f
r
a
c
t
i
o
n
(
%
)
8
5
6
5
5
4
M
y
o
c
a
r
d
i
a
l
u
p
t
a
k
e
(
%
)
M
a
x
3
.
7
S
t
r
e
s
s
a
t
5
m
i
n
:
1
.
5
a
t
6
0
m
i
n
:
1
.
4
R
e
s
t
:
1
.
2
S
t
r
e
s
s
a
t
5
m
i
n
:
1
.
3
a
t
6
0
m
i
n
:
1
.
1
R
e
s
t
:
1
.
2
B
e
s
t
u
p
t
a
k
e
M
o
r
e
m
y
o
c
a
r
d
i
a
l
c
o
u
n
t
s
u
n
d
e
r
s
t
r
e
s
s
L
e
s
s
l
i
n
e
a
r
m
y
o
c
a
r
d
i
a
l
u
p
t
a
k
e
w
i
t
h
i
n
c
r
e
a
s
i
n
g
b
l
o
o
d
f
o
w
T
h
r
e
e
r
a
d
i
o
p
h
a
r
m
a
c
e
u
t
i
c
a
l
s
f
o
r
m
y
o
c
a
r
d
i
a
l
p
e
r
f
u
s
i
o
n
i
m
a
g
i
n
g
a
r
e
c
u
r
r
e
n
t
l
y
a
v
a
i
l
a
b
l
e
i
n
t
h
e
E
u
r
o
p
e
a
n
m
a
r
k
e
t
.
T
h
a
l
l
i
u
m
w
a
s
t
h
e
f
r
s
t
t
o
b
e
i
n
t
r
o
d
u
c
e
d
,
f
o
l
l
o
w
e
d
b
y
T
c
-
9
9
m
s
e
s
t
a
m
i
b
i
a
n
d
T
c
-
9
9
m
t
e
t
r
o
f
o
s
m
i
n
.
R
a
d
i
o
p
h
a
r
m
a
c
e
u
t
i
c
a
l
F
e
a
t
u
r
e
s
Imaging and Processing
Julie Martin and Audrey Taylor
E
A
N
M
37
R
e
d
i
s
t
r
i
b
u
t
i
o
n
Y
e
s
N
o
t
s
i
g
n
i
f
c
a
n
t
N
o
1
i
n
j
e
c
t
i
o
n
(
1
i
n
j
e
c
t
i
o
n
)
A
t
s
t
r
e
s
s
,
i
m
a
g
i
n
g
w
i
t
h
i
n
5
-
1
0
m
i
n
(
p
o
s
s
i
b
l
e
u
p
w
a
r
d
c
r
e
e
p
a
r
t
i
f
a
c
t
s
)
2
i
n
j
e
c
t
i
o
n
s
G
r
e
a
t
e
r
f
e
x
i
b
i
l
i
t
y
i
n
i
m
a
g
i
n
g
t
i
m
e
a
n
d
i
n
p
r
o
t
o
c
o
l
c
h
o
i
c
e
A
c
q
u
i
s
i
t
i
o
n
c
o
u
l
d
b
e
r
e
p
e
a
t
e
d
a
t
s
t
r
e
s
s
i
f
:
P
a
t
i
e
n
t
m
o
v
e
d
S
u
p
i
n
e
+
p
r
o
n
e
T
e
c
h
n
i
c
a
l
i
s
s
u
e
2
i
n
j
e
c
t
i
o
n
s
G
r
e
a
t
e
r
f
e
x
i
b
i
l
i
t
y
i
n
i
m
a
g
i
n
g
t
i
m
e
a
n
d
i
n
p
r
o
t
o
c
o
l
c
h
o
i
c
e
A
c
q
u
i
s
i
t
i
o
n
c
o
u
l
d
b
e
r
e
p
e
a
t
e
d
a
t
s
t
r
e
s
s
i
f
:
P
a
t
i
e
n
t
m
o
v
e
d
S
u
p
i
n
e
+
p
r
o
n
e
T
e
c
h
n
i
c
a
l
i
s
s
u
e
S
t
a
n
d
a
r
d
d
o
s
e
*
(
M
B
q
)
A
b
o
v
e
7
0
k
g
1
1
1
(
3
7
)
+
1
.
1
/
k
g
1
-
d
a
y
p
r
o
t
o
c
o
l
1
s
t
d
o
s
e
:
2
5
0
2
n
d
d
o
s
e
:
7
5
0
2
-
d
a
y
p
r
o
t
o
c
o
l
1
,
0
0
0
+
1
0
/
k
g
(
d
a
i
l
y
d
o
s
e
)
1
-
d
a
y
p
r
o
t
o
c
o
l
1
s
t
d
o
s
e
:
2
5
0
2
n
d
d
o
s
e
:
7
5
0
2
-
d
a
y
p
r
o
t
o
c
o
l
1
,
0
0
0
+
1
0
/
k
g
(
d
a
i
l
y
d
o
s
e
)
D
o
s
e
l
i
m
i
t
e
d
b
y
d
o
s
i
m
e
t
r
y
H
i
g
h
e
r
d
o
s
e
(
i
m
p
r
o
v
e
d
i
m
a
g
e
q
u
a
l
i
t
y
)
H
i
g
h
e
r
d
o
s
e
(
i
m
p
r
o
v
e
d
i
m
a
g
e
q
u
a
l
i
t
y
)
E
C
G
-
g
a
t
e
d
S
P
E
C
T
N
o
Y
e
s
Y
e
s
N
o
t
r
e
c
o
m
m
e
n
d
e
d
a
s
l
o
w
e
r
c
o
u
n
t
s
s
t
a
t
i
s
t
i
c
s
(
r
e
s
u
l
t
s
l
e
s
s
r
e
p
r
o
d
u
c
i
b
l
e
)
I
m
p
r
o
v
e
d
s
p
e
c
i
f
c
i
t
y
f
o
r
p
e
r
f
u
s
i
o
n
a
n
a
l
y
s
i
s
V
e
n
t
r
i
c
u
l
a
r
f
u
n
c
t
i
o
n
I
m
p
r
o
v
e
d
s
p
e
c
i
f
c
i
t
y
f
o
r
p
e
r
f
u
s
i
o
n
a
n
a
l
y
s
i
s
V
e
n
t
r
i
c
u
l
a
r
f
u
n
c
t
i
o
n
*
A
l
l
o
w
a
b
l
e
u
p
p
e
r
l
i
m
i
t
s
o
f
r
a
d
i
o
t
r
a
c
e
r
s
m
a
y
d
i
f
e
r
f
r
o
m
c
o
u
n
t
r
y
t
o
c
o
u
n
t
r
y
.
P
l
e
a
s
e
r
e
f
e
r
t
o
t
h
e
S
u
m
m
a
r
y
o
f
P
r
o
d
u
c
t
C
h
a
r
a
c
t
e
r
i
s
t
i
c
s
i
n
e
a
c
h
E
u
r
o
p
e
a
n
c
o
u
n
t
r
y
.
Chapter 5: Imaging and Processing Julie Martin and Audrey Taylor
38
Fraction of Adult Administered Activity
3 kg = 0.1 22 kg = 0.50 42 kg = 0.78
4 kg = 0.14 24 kg = 0.53 44 kg = 0.80
6 kg = 0.19 26 kg = 0.56 46 kg = 0.82
8 kg = 0.23 28 kg = 0.58 48 kg = 0.85
10 kg = 0.27 30 kg = 0.62 50 kg = 0.88
12 kg = 0.32 32 kg = 0.65 5254 kg = 0.90
14 kg = 0.36 34 kg = 0.68 5658 kg = 0.92
16 kg = 0.40 36 kg = 0.71 6062 kg = 0.96
18 kg = 0.44 38 kg = 0.73 6466 kg = 0.98
20 kg = 0.46 40 kg = 0.76 68 kg = 0.99
Dosage for Children
The following table* from the Paediatric Committee of the EANM may be used (1):
Thallium-201 Adult 15 y-old 10 y-old 5 y-old 1 y-old
Efective dose (Sv/MBq) 231 319 1,265 1,724 2,940
* This table summarizes the views of the Paediatric Committee of the European Association of Nuclear
Medicine. It should be taken in the context of good practise of nuclear medicine and local regulation.
Thallium Dosimetry by Age of Patient
Thallium should be avoided for children because of its dosimetry (2).
Drug interactions with radiopharmaceuticals
None yet known.
Delay between Injection and Imaging - Tc-99m Sestamibi and Tc-99m Tetrofosmin
First study Second study Imaging period
between injection rest/
stress and scan (min)
Waiting period bet-
ween injections (min)
Rest
Stress
Stress
Rest
30-60
30-60
100
100-180
E
A
N
M
39
Imaging should begin 30-60 min after injec-
tion to allow for hepato-biliary clearance; lon-
ger delays are required for resting images and
for stress with vasodilators alone due to higher
liver uptake.
After the injection, patients are asked to walk
around and then eat a fatty meal to aid tracer
clearance from the liver and gall bladder.
Patients are also asked to drink two or three
glasses of water 15 min prior to imaging.
Thallium studies
Imaging should begin within 5 min of the
stress study injection and be completed
within 30 min of injection. This ensures that
redistribution has not yet taken place. Redis-
tribution imaging should be performed 3-4
hours after stress injection.
If the redistribution images are unsatisfactory,
some centres then give a resting injection
(ideally after sublingual nitrates) and image
again after a further hour.
Dual-isotope protocol
Some centres perform a dual-isotope protocol
with thallium injected at rest, followed by a Tc-
99m labelled agent injected at stress.
Patient positions
The patient should be supine with both arms
above the head and supported in a comfort-
able position. Knee support is also helpful and
patient comfort is essential to minimise mo-
tion. Prone imaging has been used in some
centres to reduce the incidence of inferior
attenuation artifacts, but it can produce an-
terior artifacts and is not recommended in
isolation.
In some centres female patients are imaged
without underclothes. A chest band can be
used to minimise breast attenuation and to
ensure reproducible positioning during later
image acquisition. This can however increase
attenuation depending on how the band is
applied so careful attention must be paid to
technique when the breasts are strapped.
Chest bands can also be used in males to re-
duce motion.
The patient is positioned so that the heart is
in the feld of view. Immobilisation aids should
be used to minimise patient movement and
to ensure patient comfort, with arms raised
above head. It may be more comfortable for
the patient to have their left arm above their
head and their right arm either under their
bottom or in a pocket, but take care if the in-
jection site is in the right arm. However, it is
important that the patient is not rotated.
The camera is positioned to minimise patient-
camera distance for the complete 180 SPECT
rotation.
It is extremely important that the same op-
erator performs both stress and rest studies
whenever possible. It is essential that the
Chapter 5: Imaging and Processing Julie Martin and Audrey Taylor
40
camera/patient positioning is reproduced as
closely as possible for rest and stress in order
to ensure accurate comparison between the
images. Where available, parameters such as
bed height and lateral movements can be re-
corded for reproducibility.
The study can be performed using an LFOV
camera or dedicated cardiac camera (e.g.
Optima), with an LEHR collimator when us-
ing the Technetium agents, and LEGP when
using Thallium and software zoom.
Gated SPECT with or without attenuation cor-
rection should be used as appropriate.
Image magnifcation
A software zoom can be used, depending on
the chosen camera.
Suggested Acquisition Parameters
Matrix 64 x 64
Frame time Thallium
Tc-99m agents
40 sec/view
30-40 sec/view
No. of projections 32 or 64 depending on camera
used (dual or single head)
180
Provision of both attenuated corrected and
non-attenuated data should be available
where possible.
ECG gating can be performed (unless HR is
irregular), particularly with Tc-99m labelled ra-
diopharmaceuticals. 8/16 frames per cardiac
cycle should be acquired for accurate calcula-
tion of left ventricular ejection fraction, depen-
dent on the camera used.
The technologist should adjust the time per
view if the count rate is lowered, e.g. due to
patient size, tissued injection or imaging de-
lays.
E
A
N
M
4l
Processing instructions - reconstruction
Filtered back projection using Butterworth
and Hanning flters is the most common
method of reconstruction. Cut-of frequen-
cies as per the manufacturers recommenda-
tions, e.g. 0.5 cycles per cm (order 5 or 10) and
0.75 cycles per cm respectively can be chosen;
these should be the same for each patient
and should not be altered to compensate for
low-count images in order to maintain consis-
tency of appearance. Iterative reconstruction
is preferred if attenuation correction has been
performed, and can also be used without at-
tenuation correction.
The long axis of the left ventricle runs from the
apex to the centre of the mitral valve, and def-
nition of this axis can be manual or automatic.
Automatic defnitions should be checked and
adjusted if necessary. The defnition should
be consistent in both stress and rest stud-
ies, bearing in mind that the orientation of
the ventricle may change slightly between
acquisitions.
The transverse tomograms are reoriented into
three sets of oblique tomograms: (1) short axis
(perpendicular to the long axis of the left ven-
tricle), (2) vertical long axis (parallel to the long
axis of the left ventricle and to the septum),
and (3) horizontal long axis (parallel to the long
axis of the left ventricle and perpendicular to
the septum) (Fig 5).
Display of a Tc-99m Sestamibi SPECT (Figure 5)
Short axis - stress
Short axis - rest
Vertical long axis - stress
Vertical long axis - rest
Horizontal long axis - stress
Horizontal long axis - rest
Chapter 5: Imaging and Processing Julie Martin and Audrey Taylor
42
Image evaluation
The planar projection images and the recon-
structed tomograms should be inspected
immediately after acquisition by an operator
or practitioner in order to identify technical
problems that might require repeat acquisi-
tion. These might include:
injection site or external objects passing
across the heart
patient motion
inaccurate ECG gating
problems related to the detector(s), such
as drift in energy window and artifact(s)
generated by transition between the two
detectors
inappropriate collimation or energy
windows
gut activity encroaching into the heart
wall
Image display
Stress and rest images should be appropri-
ately aligned and presented in a format that
allows ready comparison of corresponding
tomograms, such as interactive displays that
triangulate the three planes or display the full
set of tomograms. Each tomographic acquisi-
tion should be displayed with the top of the
colour scale at the maximum within the myo-
cardium for each set.