Joint Design: ƩM 6/5ƩM ƩM ƩM ƩM /ƩM

The document provides details of a joint design for a beam including reinforcement amounts, forces, moments, and shear calculations. It includes parameters like beam width, reinforcement areas, depths, forces, moments, and shear values. It also checks the ratio of summed moments to see if the design is acceptable.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views4 pages

Joint Design: ƩM 6/5ƩM ƩM ƩM ƩM /ƩM

The document provides details of a joint design for a beam including reinforcement amounts, forces, moments, and shear calculations. It includes parameters like beam width, reinforcement areas, depths, forces, moments, and shear values. It also checks the ratio of summed moments to see if the design is acceptable.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

JOINT DESIGN

beam width
As(top)
18

As(bottom)
4.03

T1=

1.25*Asfy=

M(-)=

1.25*Asfy(d-a/2)=

d
2.06
302.25 kips

As(top)
a for As(-) a for As(+)
25mm
20mm 16mm
25 5.267974 2.6928
3
3
1
As(bottom)
25mm
20mm 16mm
0
3
2

563.3439542 k-ft
x

T2=

1.25*Asfy=

154.5 kips

M(+)=

1.25*Asfy(d-a/2)=

317.4150327 k-ft

Vcol =

[M(-)+M(+)]/12 =

80.06899881 kips

Vu =

T1 + T2 -Vcol =

376.6810012 kips

combined on four sides =20fc'^.5*Aj =

502.8668 kips

combined on 3 sides or 2oppo =15fc'^.5*Aj =

377.1501 kips

for other joints =12fc'^.5*Aj =

301.7201 kips

Mc=6/5Mb
MB=

704.6071895 k-ft

MC =
Mc/Mb =0.73799985 Not OK

520 k-ft

1 inch

joint depth h
25

joint depth h

JOINT DESIGN
beam width
As(top)
18

As(bottom)
6

T1=

1.25*Asfy=

M(-)=

1.25*Asfy(d-a/2)=

d
3.16
450 kips

As(top)
a for As(-) a for As(+)
25mm
20mm 16mm
25 7.843137 4.1307
6
3
As(bottom)
25mm
20mm 16mm
1
5

790.4411765 k-ft
x

T2=

1.25*Asfy=

237 kips

M(+)=

1.25*Asfy(d-a/2)=

452.9591503 k-ft

Vcol =

[M(-)+M(+)]/12 =

113.0363933 kips

Vu =

T1 + T2 -Vcol =

573.9636067 kips

combined on four sides =0.85*20fc'^.5*Aj =

628.5835 kips

combined on 3 sides or 2oppo =0.85*15fc'^.5*Aj =471.4376 kips


for other joints =0.85*12fc'^.5*Aj =

377.1501 kips

Mc=6/5Mb
MB=

994.7202614 k-ft

MC =
Mc/Mb =0.522760036 Not OK