Bending and deflection calculation
Penstock Pipe
Input Data:
D
2032 mm
Penstock Pipe External Diameter
16 mm
Penstock Pipe Wall Thickness
10 mm
Maximum Expected Deflection
7.2 m
Cantilever Span of Penstock pipe
210 10
9.81
Young's Modulus of Elasticity
MPa
m
2
s
350 MPa
UTS
Accleration Due to Gravity
Material Yield Strength
490 MPa
Ultimate Tensile Strength
kg
3
m
kg
7850
s
3
m
Density of Water
1000
Density of Steel
Calculation
D
2 t
o
D
D
Z
Internal Diameter of Penstock pipe
0.0507 m
0.065 m
Elastic Scection Modulus PS Pipe
Plastic Scection Modulus PS Pipe
2
i
4
I 0.0515 m
Moment of Inertia
64
2m
4
4
D
o
i
32 D
o
o
4
g
2
N
m
Weight of water inside pipe
7803.6727
N
m
Weight of steel
w 38622.6967
N
m
Unit weight per meter (Self-Weight)
30819.0239
1/4
Deflection at Guided End (Maxumum Deflection)
3
4
F L
w L
max 12 E I 24 E I
(Maximum Deflection=Load exerted by Powerhouse (Point Load)+UDL due to Self Weight)
Deflection will be maximum at free end
4
w L
12 E I
max 24 E I
3
L
F 3.337 10
max
Load required to achieve 10 mm deflection
Bending Moment & Stress at Guided End (Ma)
w L
6
F L
2
1.2347 10
N m
Bending Moment at Guided End
243.6518 MPa
Bending Stress at Guided End
FOS
FOS
1.4365
Factor of Safety
Bending Moment & Stress at Fixed End (Mb)
w L
3
F L
2
1.2681 10
N m
Bending Moment at Guided End
250.2371 MPa
Bending Stress at Guided End
FOS
FOS
1.3987
Factor of Safety
Shear Stress at Fixed End (Maximum Shear Stress)
S
max
F w L
D
A
max
max
3.6151 10
A 0.1013 m
Maximum Shear Force
C/S area of Penstock Pipe
4
S
max
A
max
35.6743 MPa
Maximum Shear Stress
Checking for Local Buckling
(Ref: American Institute of Steel Construction (AISC) Specification 2010
Chapter F: F-8 Round HSS)
r
max
0.45
max
270
Maximum D/t ratio
r 127
o
which is less than max. Hence OK
t
Penstock pipe section is noncompact. so, r is
r
2/4
0.31
186
r
which is > r
Limiting width-to-Thickness ratio
for noncompact/slender member
Hence, for Noncompact Section,
M
n1
0.021 E
D
o
t
n2
n1
2.276 10
1.95 10
n2
N m
N m
Nominal Flexural strength for
noncompact Sections due to Yielding
Nominal Flexural strength for
noncompact Sections due to Local
Buckling
for Section with Slender walls,
M
0.33 E
Z
e
D
o
t
n3
M
M
Hence M
M
FOS
Mn
2.765 10
n3
n2
n1
N m
Nominal Flexural strength for
Sections with Slender Wall due to
Local Buckling
n3
Nominal Flexural Strength, Mn, shall
be the lower value obtained.
n2
FOS
FOS
Mn
Mn
1.537
Factor of Safety for Flexural Strength
1.5
OK as per ASCE MOP 79 for Steel Liners
Equivalent Stress Calculation
H
161.3 m
0.3 H
g
w
Gross Head at PS Section
H 209.69 m
g H
P 2.057 10
Design Head including 30% Surge Head
6
Pa
Design water pressure
P D
i
2 t
FOS
FOS
h
2
128.566 MPa
h
2.722
Hoop Stress
Factor of Safety for Hoop Stress
64.283 MPa
Longitudinal Stress due to pressure
Longitudinal Stress due to pressure and bending
te
co
te
co
314.52 MPa
185.954 MPa
Longitudinal Tensile Stress (Top of
the Pipe at Fixed End)
Longitudinal Compressive Stress
(Bottom of the Pipe at Fixed End)
So
S
S
e1
e1
2
h
te
Equivalent Stress -Mises Hencky Theory
(At top of pipe)
2
te
273.89 MPa
And
e1
OK
(Ref: ASCE Manuals and Reports on
Engineering Practice No. 79
- 3.4.13: Equivalent Stresses)
3/4
S
S
e2
e2
2
h
co
Equivalent Stress -Mises Hencky Theory
(At top of pipe)
2
co
273.89 MPa
e2
OK
(Ref: ASCE Manuals and Reports on
Engineering Practice No. 79
- 3.4.13: Equivalent Stresses)
Check for Operation Conditions
UTS
2.4
all
y
1.5
if a b
b
else
a
all
204.167 MPa
(Ref: ASCE Manuals and Reports on
Engineering Practice No. 79
- 3.5.3: Allowable Stress Intensities
Basic Allowable stress intensity
shall be minimum value obtained from
(UTS/2.4) and (y/1.5)
Welding Joint Efficiency for 100% RT
and double welded
For Normal Conditions
(Ref: ASCE Manuals and Reports on Engineering Practice No. 79 - Table 3-5)
K
Stress Increase Factor
So
N
all
all
all
all
204.167 MPa
Allowable stress for Normal Condition
Greater than the Hoop Stress(h):
Hence OK
For Emergency Conditions
(Ref: ASCE Manuals and Reports on Engineering Practice No. 79 - Table 3-5)
K
1.5
Stress Increase Factor
So
E
all
all
all
all
306.25 MPa
S
e2
4/4
Allowable stress for Normal Condition
Greater than Equivalent stress(Se2):
Hence OK