TimeProvider 5000
IEEE 1588 Grand Master Clock
Users Guide
Revision A December 2008
Part Number 098-00028-000
Symmetricom, Inc.
2300 Orchard Parkway
San Jose, CA 95131-1017
U.S.A.
http://www.symmetricom.com
Copyright 2008 Symmetricom, Inc.
All rights reserved. Printed in U.S.A.
All product names, service marks, trademarks, and registered trademarks
used in this document are the property of their respective owners.
Contents
How to Use This Guide
Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Who Should Read This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Structure of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Conventions Used in This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Warnings, Cautions, Recommendations, and Notes . . . . . . . . . . . . . . . . . . . .17
Related Documents and Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Where to Find Answers to Product and Document Questions . . . . . . . . . . . . .18
Whats New In This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Chapter 1
Overview of the TimeProvider 5000
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
TimeProvider 5000 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
UTI Input and Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Communications Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Input Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Power and Ground Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
IMC Module LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
IOC Module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Communication Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Synchronization and Timing Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Synchronization and Timing Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
System Inputs and Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Configuration Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Chapter 2
Engineering and Ordering Procedures
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
Table of Contents
TimeProvider 5000 Part Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
System and Accessory Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . .30
GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
User-Supplied Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Chapter 3
Installing the TimeProvider 5000
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Site Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Installation Tools and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Unpacking the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Rack Mounting the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Working With Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Handling Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Inserting Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Removing Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Communications Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Synchronization and Timing Connections. . . . . . . . . . . . . . . . . . . . . . . . .45
Connecting the GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Making Ground and Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Power Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Testing Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Installation Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Applying Power to the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Normal Power Up Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Chapter 4
General Guidelines for using TimeProvider 5000
CLI commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Logging In And Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Adding And Deleting Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Saving The Present Configuration To Non-volatile Memory. . . . . . . . . . .56
Restoring Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Determining Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Forcing Unit To Send New Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Configuring Static IP (default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Configuring Dynamic IP (DHCP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Switching Active And Standby Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
4
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Table of Contents
Chapter 5
Provisioning
Establishing a Connection to the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . .60
Communicating Through the Serial Port. . . . . . . . . . . . . . . . . . . . . . . . . .60
Communicating Through the Ethernet Port . . . . . . . . . . . . . . . . . . . . . . .60
Managing the User Access List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Adding a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Deleting A User. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Displaying Current Users and User Access Levels . . . . . . . . . . . . . . . . .64
Changing a Users Password and Access Level . . . . . . . . . . . . . . . . . . .64
Provisioning a RADIUS Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Provisioning Login Authentication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Provisioning the Ethernet Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Static IP Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
DHCP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Provisioning IOC Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Provisioning VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Provisioning PTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Setting the System Date Time and Time Offset . . . . . . . . . . . . . . . . . . . . . . . .68
Provisioning the Input Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Setting the GPS Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Setting the E1 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Provisioning Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Disabling Specific Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Showing Current Alarm Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Showing Current Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Displaying Alarm and Unit Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Routine Operation Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Displaying Alarms Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Displaying Events Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Restarting the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Saving and Restoring Provisioning Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Backing up Provisioning Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Simple Network Management Protocol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
SNMP Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
SNMPv3 Security Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
Table of Contents
SNMP Users and Manager Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Enabling SNMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Adding a Manager IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Adding and Removing SNMP Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Displaying SNMP Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Chapter 6
Maintenance and Troubleshooting
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
ESD Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Diagnosing the IOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Reading LED Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Removing the IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Replacing the IOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Diagnosing the IMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Reading LED Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Replacing the IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
Repairing the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
Obtaining Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Upgrading the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Upgrading the IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Upgrading the IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
Returning the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Repacking the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Equipment Return Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Users Guide Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Appendix A
System Messages
Message provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Facility codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Severity codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
System Notification Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
System State and Status Change Notifications . . . . . . . . . . . . . . . . . . . . . . . .98
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Table of Contents
Appendix B
terface
Command Descriptions and Communications In-
CLI Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
TimeProvider 5000 CLI Command Conventions . . . . . . . . . . . . . . . . . .104
CLI Command Keyboard Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
Command Line Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
Command User Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
TimeProvider 5000 CLI Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Simple Network Management Protocol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170
SNMP Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170
SNMPv3 Security Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170
Management Information Base. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170
SNMP Users and Manager Addresses . . . . . . . . . . . . . . . . . . . . . . . . . .171
Secure Shell Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172
Secure File Transfer Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172
Appendix C
Specifications and Factory Defaults
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
LAN Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Alarm Default Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
Appendix D
Installing the GPS Antenna
Antenna Kits and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
Selecting the Proper Gain Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
Transient Eliminators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
GPS L1 Inline Amplifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
GPS L1 Inline Amplifier Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Antenna Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
Table of Contents
Installing Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Antenna Connection Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Planning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Antenna Installation Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . .194
Cutting Antenna Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
Installing the Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
Connecting the Cable to the Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . .195
Installing the Transient Eliminator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196
Installing the Antenna Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
Connecting the GPS Antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
Antenna Installation Completeness Checklist. . . . . . . . . . . . . . . . . . . . .198
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
Contacting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
Appendix E
Software Licenses
Third-Party Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Figures
1-1
1-2
1-3
1-4
1-5
1-6
1-7
1-8
TimeProvider 5000 Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . .21
Serial Port Male Connector Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
PTP Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
GPS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Power and Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
TimeProvider 5000 Modules and Power Connections. . . . . . . . . . . . . . . . .25
TimeProvider 5000 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
3-9
3-10
3-11
3-12
3-13
B-1
Location of Product Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Installing the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Chassis Dimensions - Side View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Chassis Dimensions - Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Chassis Dimensions - Top View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
IMC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Serial Port Male Connector Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
PTP Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
E1 Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
TimeProvider 5000 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Universal Ground Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
TimeProvider 5000 Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Power and Ground Connections on the TimeProvider 5000 . . . . . . . . . . . .50
TimeProvider 5000 CLI Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . .104
D-1
D-2
Locating the GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
GPS Antenna Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
List of Figures
10
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Tables
1-1
Serial Port Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . .22
2-1
2-2
2-3
2-4
3-1
3-2
3-3
3-4
Component Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Connection Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
GPS Antenna Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
GPS Roof Mount Cables (spares and replacements only) . . . . . . . . . . . . .32
Management Ethernet Connector Pin Assignments . . . . . . . . . . . . . . . . . .44
Serial Port Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Installation Completeness Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Module LED Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
5-1
User Level and Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
6-1
6-2
6-3
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
LED Conditions for the IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
LED Conditions for the IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
A-1
A-2
System Notification Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
System Provisioning Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
C-1
C-2
C-3
C-4
C-5
C-6
C-7
C-8
C-9
C-10
C-11
C-12
C-13
C-14
C-15
TimeProvider 5000 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . .174
TimeProvider 5000 Environmental Specifications . . . . . . . . . . . . . . . . . . .174
TimeProvider 5000 Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . .175
Serial Port Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
LAN Port Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
Input Signal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Output Signal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
General and Communication Parameters . . . . . . . . . . . . . . . . . . . . . . . . .177
GPS and Input Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
Output Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
PTP Grand Master Port IP Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . .180
VLAN Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
PTP Grand Master Common Parameters . . . . . . . . . . . . . . . . . . . . . . . . .181
PTP Grand Master Unicast Parameters . . . . . . . . . . . . . . . . . . . . . . . . . .182
GPS Port Alarm Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
D-1
D-2
D-3
D-4
GPS Antennas with Internal LNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
Specifications for GPS Antennas with Internal LNA . . . . . . . . . . . . . . . . .187
26 dB L1 GPS Antenna Accessory Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .188
FCC-250B-90-1.5NFNF Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .188
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
11
List of Tables
D-5
D-6
D-7
12
GPS L1 Inline Amplifier Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Antenna Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
How to Use This Guide
This section describes the format, layout, and purpose of this guide.
In This Preface
Purpose of This Guide
Who Should Read This Guide
Structure of This Guide
Conventions Used in This Guide
Warnings, Cautions, Recommendations, and Notes
Related Documents and Information
Where to Find Answers to Product and Document Questions
Whats New In This Guide
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
13
How to Use This Guide
Purpose of This Guide
Purpose of This Guide
The TimeProvider 5000 Users Guide describes the procedures for unpacking,
installing, using, maintaining, and troubleshooting the Symmetricom TimeProvider
5000 Precision Timing Protocol Grand Master (TimeProvider 5000). It also includes
appendixes that describe alarms and events, the languages that you use to
communicate with the TimeProvider 5000, default values, and other information.
Who Should Read This Guide
Chapter 1, Overview of the TimeProvider 5000, is written for non-technical
audiences who need general information about the product. Chapter 2, Engineering
and Ordering Procedures, and subsequent chapters contain technical information
about the product. Other chapters and appendixes describe installation,
maintenance, and configuration instructions or details primarily intended for
qualified maintenance personnel.
This Users Guide is designed for the following categories of users:
Systems Engineers Chapter 1 provides an introduction to the TimeProvider
5000, Cross-references in this chapter direct you to detailed system information
in other chapters as appropriate.
Installation Engineers Chapter 2 through Chapter 6 and the appendixes
provide detailed information and procedures to ensure proper installation,
operation, configuration, and testing of the TimeProvider 5000.
Maintenance Engineers Chapter 6 and the appendixes provide preventive
and corrective maintenance guidelines, as well as procedures for diagnosing and
troubleshooting fault indications and alarms.
While Chapter 1 is written for non-technical audiences who need information about
the TimeProvider 5000 system, others, such as Chapter 2 through Chapter 6
contain detailed information and instructions which are intended to be performed by
qualified personnel only.
14
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
How to Use This Guide
Structure of This Guide
Structure of This Guide
This guide contains the following sections and appendixes:
Chapter, Title
Description
Chapter 1, Overview of the
TimeProvider 5000
Provides an overview of the product, describes the major
hardware and software features, and lists the system
specifications.
Chapter 2, Engineering and
Ordering Procedures
Lists the part number and ordering procedure for all TimeProvider
5000 parts and accessories.
Chapter 3, Installing the
TimeProvider 5000
Contains procedures for unpacking and installing the system, and
for powering up the unit.
Chapter 4, General Guidelines for Provides basic information to which users can refer to ensure
using TimeProvider 5000
proper system operation.
Chapter 5, Provisioning
Describes the commands and procedures required to provision the
TimeProvider 5000 after installing the unit.
Chapter 6, Maintenance and
Troubleshooting
Contains preventive and corrective maintenance, and
troubleshooting procedures for the product.
Appendix A, System Messages
Lists the alarms and events and provides basic indications of the
source of the alarm.
Appendix B, Command
Descriptions and
Communications Interface
Describes the CLI command conventions, functions, and features
and the SNMP, SSH, and SFTP protocols.
Appendix C, Specifications and
Factory Defaults
Lists the specifications for the TimeProvider 5000.
Appendix E, Software Licenses
Contains licensing information for third party software.
Index
Provides references to individual topics within this guide.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
15
How to Use This Guide
Conventions Used in This Guide
Conventions Used in This Guide
This guide uses the following conventions:
Acronyms and Abbreviations Terms are spelled out the first time they appear
in text. Thereafter, only the acronym or abbreviation is used.
Revision Control The title page lists the printing date and versions of the
product this guide describes.
Typographical Conventions This guide uses the typographical conventions
described in the table below.
When text appears
this way...
16
... it means:
TimeProvider 5000 Users
Guide
The title of a document.
CRITICAL
An operating mode, alarm state, status, or chassis label.
Select File, Open...
Click the Open option on the File menu.
Press Enter
Press;
A named keyboard key.
The key name is shown as it appears on the keyboard.
An explanation of the keys acronym or function
immediately follows the first reference to the key, if
required.
Username:
Text in a source file or a system prompt or other text that
appears on a screen.
ping
status
A command you enter at a system prompt or text you
enter in response to a program prompt. You must enter
commands for case-sensitive operating systems exactly
as shown.
qualified personnel
A word or term being emphasized.
Symmetricom does not
recommend...
A word or term given special emphasis.
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
How to Use This Guide
Warnings, Cautions, Recommendations, and Notes
Warnings, Cautions, Recommendations, and Notes
Warnings, Cautions, Recommendations, and Notes attract attention to essential or
critical information in this guide. The types of information included in each are
explained in the following examples.
Warning: To avoid serious personal injury or death, do not disregard
warnings. All warnings use this symbol. Warnings are installation,
operation, or maintenance procedures, practices, or statements, that
if not strictly observed, may result in serious personal injury or even
death.
Caution: To avoid personal injury, do not disregard cautions. All
cautions use this symbol. Cautions are installation, operation, or
maintenance procedures, practices, conditions, or statements, that if
not strictly observed, may result in damage to, or destruction of, the
equipment. Cautions are also used to indicate a long-term health
hazard.
ESD Caution: To avoid personal injury and electrostatic discharge
(ESD) damage to equipment, do not disregard ESD cautions. All ESD
cautions use this symbol. ESD cautions are installation, operation, or
maintenance procedures, practices, conditions, or statements that if
not strictly observed, may result in possible personal injury,
electrostatic discharge damage to, or destruction of, static-sensitive
components of the equipment.
Electrical Shock Caution: To avoid electrical shock and possible
personal injury, do not disregard electrical shock cautions. All
electrical shock cautions use this symbol. Electrical shock cautions
are practices, procedures, or statements, that if not strictly observed,
may result in possible personal injury, electrical shock damage to, or
destruction of components of the equipment.
Recommendation: All recommendations use this symbol.
Recommendations indicate manufacturer-tested methods or known
functionality. Recommendations contain installation, operation, or
maintenance procedures, practices, conditions, or statements, that
provide important information for optimum performance results.
Note: All notes use this symbol. Notes contain installation, operation,
or maintenance procedures, practices, conditions, or statements, that
alert you to important information, which may make your task easier
or increase your understanding.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
17
How to Use This Guide
Related Documents and Information
Related Documents and Information
See your Symmetricom representative or sales office for a complete list of available
documentation.
Note: Symmetricom offers training courses designed to enhance your
knowledge of the TimeProvider 5000. Contact your local
representative or sales office for a complete list of courses and
outlines.
Where to Find Answers to Product and Document
Questions
For additional information about the products described in this guide, please contact
your Symmetricom representative or your local sales office. You can also contact us
on the web at www.symmetricom.com.
Whats New In This Guide
This is the first release of this Users Guide.
18
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 1 Overview of the TimeProvider 5000
This chapter provides introductory information for the TimeProvider 5000.
In This Chapter
Overview
TimeProvider 5000 Connections
Physical Description
Functional Description
Configuration Management
Alarms
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
19
Chapter 1 Overview of the TimeProvider 5000
Overview
Overview
The TimeProvider 5000 is a Next Generation Network (NGN) packet-based timing
and frequency device that combines the functionality of a highly-accurate, IEEE
1588 v2 Grand Master Clock with T1/E1 and 1PPS/10MHz I/O ports. The
TimeProvider 5000, available with either a Quartz or Rubidium oscillator,
incorporates hardware-based time stamping to provide the highest level of timing
and frequency accuracy over a broad range of wireline and wireless application.
The TimeProvider 5000 features are as follows:
Compact 1 RU Footprint
ETSI Compliant: Front Access for all Connectors
Dual 48 VDC Power Connectors
2 UTI Ports (future capability)
Up to 2 Legacy Inputs (T1/E1 - T1 is a future capability)
Up to 4 Legacy Outputs (E1/T1 is a future capability)
2 SFP Connectors on each IOC
1 L1 GPS Input on the IMC
1 Ethernet Mgmt Port on the IMC
1 EIA-232 Serial (Craft) Port on the IMC
LED indicators on the IOC and IMC
Hardware Protected (Redundant IOCs is a future capability)
CLI and SNMP Management
TimeProvider 5000 Connections
Figure 1-1 is a front view of the TimeProvider 5000 showing connectors and LEDs.
Connections for the GPS input signal, Ethernet Management, and EIA-232 serial
connection are located on the IMC module. Small Form-factor Pluggable (SFP)
connectors are located on the IOC modules. UTI, 10 MHz/1pps, and I/O ports are
located on the I/O module. The 1PPS/10MHz ports are optional. In the current
version of TimeProvider 5000, units have two E1 input ports. In the future customers
can order units with either four E1 I/O ports or two E1 I/O ports and a 10MHz and
1PPS port.
20
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 1 Overview of the TimeProvider 5000
TimeProvider 5000 Connections
Figure 1-1.
TimeProvider 5000 Connectors and LEDs
UTI Input and Output Connections
The UTI connectors are for future use.
Communications Connections
The IMC allows user control of the TimeProvider 5000 through either the Ethernet
Management port or the EIA-232 serial port.
Ethernet Management Port
The Ethernet Management port is standard 10/100Base-T shielded RJ-45
receptacle. To connect the TimeProvider 5000 to an Ethernet network, use a
shielded twisted pair Ethernet RJ-45 cable.
EIA-232 Serial (Craft) Port
The EIA-232 serial port connection is made through a EIA-23 female connector on
the IMC. This port allow you to connect to a terminal or computer using a terminal
emulation software package. When connecting to this port, use a shielded EIA-232
direct connect cable.
Figure 1-2 shows the EIA-232 male connector pin assignments for the serial port.
Figure 1-2.
Serial Port Male Connector Pins
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
21
Chapter 1 Overview of the TimeProvider 5000
TimeProvider 5000 Connections
Table 1-1 describes the EIA-232 connector pin assignments for the serial port.
Table 1-1. Serial Port Connector Pin Assignments
Signal
Pin
TXD (Received Data)
RXD (Transmitted Data)
Ground
Output Connections
Coaxial Output Connections
The four traditional telecom synchronization mini-BNC ports on the I/O module
(Figure 1-3) are software configurable as output ports with the following signal
types:
2.048 Mb/s (G.703/9) (future capability)
2.048 MHz (G.703/13) (future capability)
1PPS/10MHz
Note: Units that provide 1PPS/10MHz output must be ordered
from the factory; they cannot be reconfigured in the field. One
port provides 1PPS output and one port provides 10 MHz
output.
Figure 1-3.
22
I/O Module
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 1 Overview of the TimeProvider 5000
TimeProvider 5000 Connections
Notes:
1. Mini-BNC ports 1 and 2 are inputs in this release. In future
releases, they can be configured as either outputs or inputs.
2. The UTI connectors in Figure 1-3 are for future use.
PTP Output Connections
The TimeProvider 5000 provides two Ethernet 100/1000 Small-form Factor
Pluggable (SFP) connections on each IOC (see Figure 1-4). In PTP (IEEE 1588v2)
grand-master mode, the TimeProvider 5000 supports many slaves per system in
unicast mode. The TimeProvider 5000 will also support multi-cast mode (a future
capability).
Figure 1-4.
PTP Output Connections
Input Connections
E1 Input Connections
Mini-BNC ports 1 and 2 on the I/O module (see Figure 1-3) are software
configurable as traditional telecom input ports with the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
GPS Connection
The IMC has a GPS input to provide a frequency and time reference (see Figure
1-5).
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
23
Chapter 1 Overview of the TimeProvider 5000
Physical Description
Figure 1-5.
GPS Connection
Power and Ground Connections
The TimeProvider 5000 uses 48 VDC power and is not equipped with a Power
switch; DC power is controlled by a power distribution panel connected to the power
connectors. Frame ground connections are made on the grounding stud located on
the left side of the front panel, as identified with the international Ground marking.
Warning: To avoid serious personal injury or death, exercise caution
when working near high voltage lines and follow local building
electrical codes for grounding the chassis.
Figure 1-6.
Power and Ground
Physical Description
The TimeProvider 5000 consists of a 19-inch (48 cm) rack mount chassis, plug-in
modules, and hardware.
Note: The TimeProvider 5000 comes equipped with 19-inch rack
mounting brackets. 23-inch (58.42 cm) rack mounting adapters are
also available as a separately ordered item. 21-inch (ETSI) rack
mounting adapters are available as a separately ordered item.
24
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 1 Overview of the TimeProvider 5000
Functional Description
The TimeProvider 5000 has one I/O module slot, two IOC module slots, and one
IMC module slot. The grounding lug is located near the I/O module and the power
supply connectors are located on both sides of the chassis (see Figure 1-7). The
minimum configuration is an I/O module, an IOC module, and an IMC module. The
second IOC module slot is available for redundancy. See Overview, on page 30.
Figure 1-7.
TimeProvider 5000 Modules and Power Connections
Functional Description
Figure 1-8 is a block diagram of the TimeProvider 5000.
Figure 1-8.
TimeProvider 5000 Block Diagram
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
25
Chapter 1 Overview of the TimeProvider 5000
Functional Description
IMC Module LEDs
The IMC module provides connectors for 10/100 Ethernet management, EIA-232
serial management, and the GPS Timing Antenna. The IMCs LEDs indicate the
following:
Power Status
Alarm Status
GPS Signal Status
IOC Module LEDs
The IOC module also has two PTP Grand Master 100/1000 Ethernet SFP ports with
LEDs that indicate link and link speed. The IOC module has LED status indicators
and test outputs for the system. The LEDs indicate:
Power Status
Active Status
Ethernet Status
Alarm Status
Holdover Status
Communication Ports
Communications ports on the IMC allow you to provision, monitor, and troubleshoot
the chassis. You can communicate with the TimeProvider 5000 using either CLI or
SNMP protocols.
Note: The SNMP feature can either be ordered in a new system, or
added to a previously ordered system as a field upgrade (see Table
2-1 for part number). Contact your Symmetricom representative for
more information.
Local Craft Serial Port
The EIA-232 port supports local control; you can configure the TimeProvider 5000
with CLI commands using a terminal or computer with terminal emulation software.
The connector is located on the IMC module. The Local port is configured as a DCE
interface and the default settings are as follows:
26
Baud = 57.6K
Data Bits = 8 bits
Parity = None
Stop bits = 1
Flow Control, None
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 1 Overview of the TimeProvider 5000
Functional Description
Management Ethernet Port
The Management Ethernet connector provides connectivity to an Ethernet local
area network. Each Ethernet port has a unique internet protocol (IP) address and
once the IP address is set and a connection is made to a LAN, you can access the
TimeProvider 5000.
Synchronization and Timing Inputs
The TimeProvider 5000 can use either GPS or E1 signals as external input
references. The GPS reference connects to a SMA connector on the IMC card and
the E1 inputs are configurable ports located on the I/O module.
Synchronization and Timing Outputs
The TimeProvider 5000 has four GbE Precision Timing Protocol (PTP) timing
outputs (2 per IOC card).
System Inputs and Outputs
The TimeProvider 5000 has four mini-BNC ports on the I/O module that are
software configurable as either input or output ports. When configured as output
ports, they can provide the following signal types:
2.048 Mb/s (G.703/9) (future capability)
2.048 MHz (G.703/13) (future capability)
1PPS/10 MHz
Note: Units that provide 1PPS/10MHz output must be
configured at the factory when ordered; they cannot be
reconfigured in the field. One port provides 1PPS output and
one port provides 10MHz output.
Two of the mini-BNC ports are software configurable as input ports with the
following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
27
Chapter 1 Overview of the TimeProvider 5000
Configuration Management
Configuration Management
The Command Line Interface (CLI), also called the ASCII command set, can be
used to control the TimeProvider 5000 from a terminal connected to the EIA-232
serial port, or the Ethernet port. Refer to Appendix B, Command Descriptions and
Communications Interface for further details.
Note: Before you can communicate with the TimeProvider 5000
through an Ethernet connection, you must first configure the Ethernet
port using the serial connection (see Provisioning the Ethernet Ports,
on page 66).
Alarms
The TimeProvider 5000 uses alarms to notify you when certain conditions are
deteriorating below specified levels. These alarms are indicated by module status
LEDs and by SNMP traps. You can provision the alarm to either be enabled or
disabled and the current alarm state can be obtained via the communication ports.
For more information, see Provisioning Alarms, on page 70 and Appendix A,
System Messages.
28
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 2 Engineering and Ordering Procedures
This chapter describes the items available for the TimeProvider 5000, and lists the
part number for each item.
In This Chapter
Overview
TimeProvider 5000 Part Numbers
User-Supplied Tools and Materials
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
29
Chapter 2 Engineering and Ordering Procedures
Overview
Overview
The TimeProvider 5000 can operate in either a basic configuration, or in a
redundant configuration in one chassis. Basic configuration consists of the following
components:
1 Chassis
1 IMC module
1 IOC module
Note: When operating in basic configuration, blank panels are
available to cover the vacant module slots in the chassis.
Redundant configuration consists of the following components:
1 Chassis
1 IMC module
2 IOC modules
TimeProvider 5000 Part Numbers
System and Accessory Part Numbers
This section provides part numbers and descriptions for the system and accessories
available for the TimeProvider 5000. Also available as separately ordered items are
23-inch (58.42 cm) rack mounting adapters and 21-inch (ETSI) rack mounting
adapters. See Table 2-1 for component part numbers and Table 2-2 for connection
accessories.
Table 2-1. Component Part Numbers
Item
Part Number
Base Units
30
TimeProvider 5000 Front Access ETSI Chassis
includes Users Documentation CD and Installation Kit
990-50301-01
Spare TimeProvider 5000 Front Access ETSI Chassis
090-50301-01
TimeProvider 5000 Rear Access NEBS Chassis (future release)
990-50302-01
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 2 Engineering and Ordering Procedures
TimeProvider 5000 Part Numbers
Table 2-1. Component Part Numbers
Item
Part Number
I/O Modules
I/O Module with 4x E1 Ports and 2x UTI Ports
090-50311-01
I/O Module with 2x E1 Ports, 1PPS/10MHz Ports
and 2x UTI Ports
090-50312-01
Blank I/O Face Plate
090-50312-99
IOC and IMC Module
Quartz IOC Module
090-50321-01
Rubidium IOC Module
090-50322-01
Blank IOC Module Face Plate
090-50322-99
IMC Module with Integrated GPS
090-50331-01
Rack Mounting Adaptor Kits
21-inch (ETSI) Bracket Rack Mounting Adaptor Kit
093-00011-000
23-inch (58.42 cm) Bracket Rack Mounting Adaptor Kit
093-00012-000
Software Licenses
NTP Server License (future release)
920-50360-01
SNMP License
920-50370-01
Note: A blank face plate is required for EMC compliance if a
slot is empty
Table 2-2. Connection Accessories
Item
Part Number
Optical 1000 Base-SX Multi-Mode Ethernet 850nm SFP
Transceiver
121-20621-11-2
Optical 1000 Base-LX Single-Mode Ethernet 1310nm SFP
Transceiver
121-20621-10-2
RJ45 100/1000/1GbE Base-T Full-Duplex SFP Transceiver
121-20621-13-2
Mini-BNC-to-BNC Adaptor Cable Kit (4 cables)
093-00068-000
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
31
Chapter 2 Engineering and Ordering Procedures
TimeProvider 5000 Part Numbers
GPS Antenna
Table 2-3 lists the GPS antenna kits. Table 2-4 lists the cables available for the GPS
antenna.
Table 2-3. GPS Antenna Kits
Part Number
Description
990-13091-006
Antenna Kit, 6 Meter (3 meter and 3 meter cables), 26dB
Antenna
990-13091-013
Antenna Kit, 13 Meter (3 meter and 10 meter cables), 26dB
Antenna
990-13073-070
Antenna Kit, 70 Meter (10 meter and 60 meter cables),
40dB Antenna
990-13074-150
Antenna Kit, 150 Meter (10 meter and 140 meter cables),
48db Antenna
990-13075-230
Antenna Kit, 230 Meter (10 meter and 220 meter cables),
48dB Antenna/20dB Amp
Table 2-4. GPS Roof Mount Cables (spares and replacements only)
Part Number
32
Description
58521A-001
1 Meter, LMR400 Interconnect Cable, connectorized
58521A-002
2 Meter, LMR400 Interconnect Cable, connectorized
58521A-005
5 Meter, LMR400 Interconnect Cable, connectorized
58521A-010
10 Meter, LMR400 Interconnect Cable, connectorized
58521A-015
15 Meter, LMR400 Interconnect Cable, connectorized
58521A-030
30 Meter, LMR400 Interconnect Cable, connectorized
58521A-060
60 Meter, LMR400 Interconnect Cable, connectorized
58521A-110
110 Meter, LMR400 Interconnect Cable, connectorized
58521A-220
220 Meter, LMR400 Interconnect Cable, connectorized
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 2 Engineering and Ordering Procedures
User-Supplied Tools and Materials
User-Supplied Tools and Materials
You need to supply the following tools and materials for installing and testing the
TimeProvider 5000.
Standard tool kit
Cable ties, waxed string or acceptable cable clamps
1 mm / 18 AWG (minimum) stranded wire at 300 volt insulation for 48 VDC
1 mm / 16 AWG wire to connect grounding lug to permanent earth ground
Two U.L listed Ring Lugs for grounding connections
Crimping tool to crimp the ring lug
Shielded cabling of the appropriate impedance required by the specific signal
type for signal wiring (including GPS, and Ethernet)
Mating connectors for terminating signal wiring
ESD wrist strap for installing modules
Fasteners for mounting the equipment in rack
Digital multimeter or standard Voltmeter for verifying power connections to the
chassis
Laptop computer with communications software (e.g., Microsoft Hyperterminal,
ProComm Plus or EmTec ZOC) for setting system parameters
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
33
Chapter 2 Engineering and Ordering Procedures
User-Supplied Tools and Materials
34
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
This chapter describes the procedures for installing the TimeProvider 5000.
In This Chapter
Getting Started
Unpacking the Unit
Rack Mounting the Chassis
Working With Modules
Signal Connections
Connecting the GPS Antenna
Making Ground and Power Connections
Installation Check List
Applying Power to the TimeProvider 5000
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
35
Chapter 3 Installing the TimeProvider 5000
Getting Started
Getting Started
Before you begin to install the TimeProvider 5000, review the information in this
section.
If you encounter any difficulties during the installation process, contact
Symmetricom Global Services (SGS). See Obtaining Technical Assistance, on page
83 for telephone numbers. Contact SGS - Product Technical Support for technical
information. Contact Customer Service for information about your order, RMAs, and
other information.
Site Survey
Before you begin installation, determine the chassis location, ensure the
appropriate power source is available (48 VDC), and ensure that the equipment
rack is properly grounded.
The TimeProvider 5000 is designed to mount in a 19-inch (48 cm) rack, occupies
1.75 in (4.5 cm, 1 RU) of vertical rack space, and has a depth of 18 in (45.7 cm)..
Note: 1RU above the TimeProvider 5000 must be left
unoccupied for heat dissipation
Note: 23-inch (58.42 cm) rack mounting adapters are also available
as a separately ordered item. 21-inch (ETSI) rack mounting adapters
are available as a separately ordered item.
The TimeProvider 5000 is to be installed into a rack with permanent connection to
the -48VDC mains. This connection is to be made to a branch over-current,
short-circuit protection device with replaceable fusing of 5 amps, maximum. For
permanently connected equipment a readily accessible disconnect device shall be
incorporated in the building installation wiring.
Environmental Requirements
To prevent the unit from malfunctioning or interfering with other equipment, install
and operate the unit according to the following guidelines:
36
Operating temperature: 23Fto 113F (5 C to 45C)
Operating Humidity: 5% to 85% RH non-condensing
Use only shielded cable for all signal wiring, including I/O, clocks and Ethernet.
Ground appropriately at both ends, or as required by local standards.
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Unpacking the Unit
Secure all cable screws to their corresponding connectors.
Caution: To avoid interference, you must consider the
electromagnetic compatibility (EMC) of nearby equipment when you
install the TimeProvider 5000.
Electromagnetic interference can adversely affect the operation of
nearby equipment.
Installation Tools and Equipment
You will need the following tools and equipment to install the TimeProvider 5000:
Standard tool kit
Cable ties, waxed string or acceptable cable clamps
1 mm / 18 AWG (minimum) stranded wire at 300 volt insulation for 48 VDC
1 mm / 16 AWG wire to connect grounding lug to permanent earth ground
Two U.L listed Ring Lugs for grounding connections
Crimping tool to crimp the ring lug
Shielded cabling of the appropriate impedance required by the specific signal
type for signal wiring (including GPS, and Ethernet)
Mating connectors for terminating signal wiring
ESD wrist strap for installing modules
Fasteners for mounting the equipment in rack
Digital multimeter or standard Voltmeter for verifying power connections to the
chassis
Laptop computer with communications software (e.g., Microsoft Hyperterminal,
ProComm Plus or EmTec ZOC) for setting system parameters
Unpacking the Unit
The TimeProvider 5000 is packaged to protect it from normal shock, vibration and
handling damage.
Caution: To avoid electrostatic discharge (ESD) damage to parts that
are packaged with the TimeProvider 5000, observe the following
procedures.
Unpack and inspect the unit as follows:
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
37
Chapter 3 Installing the TimeProvider 5000
Unpacking the Unit
1. Wear a properly grounded protective wrist strap or other ESD device.
2. Inspect the container for signs of damage. If the container appears to be
damaged, notify both the carrier and your Symmetricom distributor. Retain the
shipping container and packing material for the carrier to inspect.
3. Open the container, being careful to cut only the packaging tape.
4. Locate and set aside the CD, printed information, and paperwork that is included
in the container.
5. Remove the unit from the container and place it on an anti-static surface.
6. Locate and set aside small parts which may be packed in the container.
7. Remove the accessories from the container.
8. Remove the anti-static packaging from the unit and accessories.
9. Verify that the model and item number shown on the shipping list agrees with the
model and item number on the equipment. The item number can be found on a
label affixed to the top of the unit, front and center. See Figure 3-1 for the location
of the label. Contact your Symmetricom distributor if the model or item number do
not match.
For a complete listing of item numbers, see Table 2-1 and Table 2-3.
Figure 3-1.
38
Location of Product Label
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Rack Mounting the Chassis
Rack Mounting the Chassis
The installation procedure described in this section provides general guidelines for
installing the TimeProvider 5000. Always follow applicable local electrical standards.
Use the following steps to mount the TimeProvider 5000 in a rack.
Note: 1RU above the TimeProvider 5000 must be left
unoccupied for heat dissipation.
Note: The TimeProvider 5000 comes equipped with 19-inch rack
mounting brackets. 23-inch (58.42 cm) rack mounting adapters are
also available as a separately ordered item. 21-inch (ETSI) rack
mounting adapters are available as a separately ordered item.
1. TimeProvider 5000 is shipped with rack mounting brackets attached. The rack
mounting brackets can be removed and reattached in a different orientation, if
desired. Ensure that the mounting brackets on both sides are attached to the
chasis at equal distances from the front of the unit (see Figure 3-2) using 6-32 x
1/4-inch screws. See Figure 3-3 for mounting hole placements. See Figure 3-4
and Figure 3-5 for chassis dimensions.
2. Mount the chassis to the front of the equipment rack rails with four screws and
associated hardware. Use the proper screws for the equipment rack.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
39
Chapter 3 Installing the TimeProvider 5000
Rack Mounting the Chassis
40
Figure 3-2.
Installing the TimeProvider 5000
Figure 3-3.
Chassis Dimensions Side View
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Rack Mounting the Chassis
Figure 3-4.
Chassis Dimensions Front View
Figure 3-5.
Chassis Dimensions Top View
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
41
Chapter 3 Installing the TimeProvider 5000
Working With Modules
Working With Modules
This section describes how to install, remove, and handle the modules associated
with the TimeProvider 5000.
Handling Modules
When handling any of the modules, observe the following precautions:
1. Use proper static control precautions when handling modules! Protect the
equipment against ESD (electrostatic discharge) by using a grounded protective
wrist strap and normal equipment grounding.
2. Avoid touching component leads and edge connectors.
3. Avoid placing the module on an ungrounded surface.
4. Avoid allowing the module to come in contact with insulated surfaces.
Inserting Modules
This procedure is common for all modules.
Caution: All modules can be removed and inserted while system
power is supplied without damaging modules; however, system
performance may be affected.
Use the following procedure to insert a module into the chassis:
1. Align the module edges within the guides of the selected slot.
2. Slide the module into the chassis and press firmly until it seats fully into its
backplane edge connector.
3. Tighten the captive screws located on each side of the panel.
Note: The I/O card does not have captive screws and requires a
Phillips screwdriver.
Caution: To avoid possible damage or intermittent failures, ensure
that you have completely inserted the module into the chassis and
that you have securely tightened the captive screws.
42
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Signal Connections
Removing Modules
To remove a module, loosen the screws and then pull out the module. Be sure to
place the module on a static-free surface.
Caution: You must disconnect the GPS antenna before removing the
IMC module.
Signal Connections
The connectors for the GPS input signal, Ethernet Management, and EIA-232 serial
connection are located on the IMC module. The PTP output connectors are located
on the IOC module. The E1 and UTI connectors are located on the I/O module.
Note: The UTI connectors are for future use.
Communications Connections
The IMC allows user control of the TimeProvider 5000. The EIA-232 serial port and
Ethernet Management port are located on the IMC as shown in Figure 3-6. See
Working With Modules, on page 42 for module installation instructions.
Figure 3-6.
IMC Module
Ethernet Management Port
The Ethernet Management port is standard 10/100Base-T shielded RJ-45
receptacle. To connect the TimeProvider 5000 to an Ethernet network, use a
shielded twisted pair Ethernet RJ-45 cable.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
43
Chapter 3 Installing the TimeProvider 5000
Signal Connections
The connector pinouts are listed in Table 3-1.
Table 3-1. Management Ethernet Connector Pin Assignments
Signal Name
Pin
TX+ (Transmit positive)
TX- (Transmit negative)
RX- (Receive negative)
RX+ (Receive positive)
Not Used
4, 5, 7, 8
EIA-232 Serial (Craft) Port
The EIA-232 serial port connection is made through a EIA-232 female connector on
the IMC. This ports allow you to connect to a terminal or computer using a terminal
emulation software package for remote monitoring and control. When connecting to
this port, use a shielded EIA-232 direct connect cable.
Figure 3-7 shows the EIA-232 male connector pin assignments for the serial port.
Figure 3-7.
Serial Port Male Connector Pins
Table 3-2 describes the EIA-232 connector pin assignments for the serial port.
Table 3-2. Serial Port Connector Pin Assignments
Signal
44
Pin
TXD (Received Data)
RXD (Transmitted Data)
Ground
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Signal Connections
Synchronization and Timing Connections
The TimeProvider 5000 has one GPS input on the IMC module, two redundant PTP
timing outputs on each IOC module, and four E1/T1 connections on the I/O module.
Two of the four E1/T1 connectors can be outputs, or inputs.
GPS Connections
To connect a GPS signal, you must install a GPS antenna. See Connecting the GPS
Antenna, on page 47. Also see Working With Modules, on page 42 for module
installation instructions.
Caution: The GPS cable should only be connected while the unit is
properly Earth grounded.
PTP Connections
The two Ethernet 10/100/1000 Small-form Factor Pluggable (SFP) connections on
each IOC provide redundant PTP outputs (see Figure 3-8).
Figure 3-8.
PTP Output Connections
The following SFP transceivers are recommended and supported:
Optical 1000 Base-SX Multi-Mode Ethernet 850nm SFP Transceiver
(Symmetricom 121-20621-11-2)
Avago AFBR-5710PZ
Finisar FTLF8519P2BNL
Optical 1000 Base-LX Single-Mode Ethernet 1310nm SFP Transceiver
(Symmetricom 121-20621-10-2)
Avago AFCT-5701PZ
Finisar FTLF1319P1BTL
RJ45 100/1000/1GbE Base-T Full-Duplex SFP Transceiver
Avago ABCU-5710RZ
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
45
Chapter 3 Installing the TimeProvider 5000
Signal Connections
Other SFP transceivers are not supported and may cause the TimeProvider 5000 to
not comply with regulatory requirements.
E1 Connections
The four E1 mini-BNC ports on the I/O module (see Figure 3-9) are software
configurable as output ports with the following signal types:
2.048 Mb/s (G.703/9) (future capability)
2.048 MHz (G.703/13) (future capability)
1PPS/10 MHz
Note: Units that provide 1PPS/10MHz output must be
configured at the factory when ordered; they cannot be
reconfigured in the field. One port provides 1PPS output and
one port provides 10MHz output
Note: Amphenol mini-BNC connectors (031-70261) can be
used to create cables. Alternatively, Symmetricom sells a kit of
4 mini-BNC to BNC adapter cables (093-00068-000).
The TimeProvider 5000 provides two ports that are software configurable as E1
input ports with the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
Figure 3-9.
46
E1 Output Connections
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Connecting the GPS Antenna
Connecting the GPS Antenna
Caution: The GPS cable should only be connected while the unit is
properly Earth grounded.
The antenna connections are made at the IMC module connector labeled GPS.
Allow at least one hour for the unit to track and lock to GPS.
Proper cable, grounding techniques, and lightning arrestors should be used. Mount
the antenna outside, preferably on the roof with a clear view of the sky. Do not
mount the antenna near a wall or other obstruction blocking part of the sky. Mount
the antenna well above roads or parking lots.
Warning: To avoid serious personal injury or death, exercise caution
when working near high voltage lines. In particular:
Use extreme caution when installing the antenna near, under, or
around high voltage lines.
Follow local building electrical codes for grounding the chassis.
Making Ground and Power Connections
Warning: To avoid accidental power-up of the chassis, remove the A
and B fuses on the branch over-current protection unit before
beginning the TimeProvider 5000 installation. The unit is not
equipped with a power on/off switch.
The TimeProvider 5000 has two 48 VDC power connectors for redundant
operation, which are located on the right and left sides of the front panel (see
Figure 3-10). A separate frame ground lug is provided on the left side of the front
panel.
Ground Connections
Frame ground connections are made using the M4 Grounding Terminal Stud
located on the left side of the front panel of the unit. This stud is marked with the
universal ground symbol, as shown in Figure 3-11.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
47
Chapter 3 Installing the TimeProvider 5000
Making Ground and Power Connections
Figure 3-10. TimeProvider 5000 Power Connections
Figure 3-11. Universal Ground Symbol
After installing the TimeProvider 5000 into the rack, connect the chassis to the
proper grounding zone or master ground bar. Run a 16 AWG green/yellow-striped
insulated wire from the TimeProvider 5000 grounding terminal to the Earth Ground
on the rack. The rack grounding method is below.
Recommendation: Although there are a number of methods for
connecting the equipment to earth ground, Symmetricom
recommends running a cable of the shortest possible length from the
ground lug to earth ground.
1. Crimp the customer-supplied U.L listed Ring Lug to one end of the 16 AWG wire
and connect it to the ground terminal on the left side of the front panel using the
supplied M4 Kept machine nut. The surface of the TimeProvider 5000 Earth
grounding terminal must be clean of contaminants and oxidation.
2. Crimp the appropriate customer-supplied U.L listed Ring Lug to the other end of
the 1 mm / 16 AWG green/yellow-striped wire. Remove the paint and sand the
area around the screw hole to ensure the proper conductivity. Coat the
connection with an electrically conductive antioxidant compound such as
Kopr-shield spray. Connect this Ring Lug to the rack with appropriate customer
supplied screws and external star lock washers.
3. Using a digital voltmeter, measure between the ground and chassis and verify
that no voltage exists between them.
48
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Making Ground and Power Connections
Power Connections
Use the following procedure to make the power connections:
Warning: To avoid possible damage to equipment, you must provide
power source protective fusing as part of the installation. The
TimeProvider 5000 is intended for installation in a restricted-access
location.
Caution: To avoid damage to the unit, remove the fuses in the fuse
panel which provides power to the TimeProvider 5000 before making
power connections.
1. Ensure the power source is turned off.
2. Connect the frame ground terminal to earth ground.
3. Locate the power connectors included in the installation kit.
4. Using 1 mm / 18 AWG (minimum) stranded wire, connect primary power to the
connectors per the polarity markings. Use the polarity markings of "-48V" and
"RTN" as a reference for the proper polarity connection..
Note:The -48VDC power must be connected with the proper polarity.
The unit will not be damaged by reverse polarity, but the unit will not
operate if the polarity is reversed.
5. Insert the connectors into the power connections in the chassis. See
Figure 3-12. Tighten screws in the connector
Figure 3-12. TimeProvider 5000 Power Connector
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
49
Chapter 3 Installing the TimeProvider 5000
Making Ground and Power Connections
Testing Power Connections
To verify that the power connections to the TimeProvider 5000 are correct, follow
the steps in this section. The connections on the primary power module are referred
to as Power A and Return A. The connections on the secondary power module are
referred to as Power B and Return B. Use a digital multimeter (Fluke 77 or
equivalent) to make the measurements.
1. Remove all fuses that supply power to the unit from the fuse panel.
2. Ensure that no IOC or IMC modules are installed in the unit.
3. Disconnect the -48V battery leads from the units power connector terminals. See
the primary and secondary power conncections in Figure 3-13. Leave the Return
battery leads connected to the unit.
Figure 3-13. Power and Ground Connections on the TimeProvider 5000
4. At the chassis end of the battery leads, use the multimeter to measure the
voltage between the following test points:
Test Point
Battery A lead
Battery A lead
Battery A lead
Battery B lead
Battery B lead
Test Point
Result
Battery B lead
0V
Primary: Return A
0V
Earth Ground
0V
Secondary: Return B 0 V
Earth Ground
0V
5. Reconnect the 48V battery A and battery B leads to the 48V A and 48V B
terminal connectors.
6. Install the A fuse in the power source fuse panel.
7. Measure the voltage between the 48V A and Return terminals on the primary
power module. The multimeter should indicate 42 VDC to 56 VDC.
8. Install the B fuse in the power source fuse panel.
9. Measure the voltage between the 48V B and Return terminals on the secondary
power module. The multimeter should indicate 42 VDC to 56 VDC.
50
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Installation Check List
The unit is now powered up.
Installation Check List
To verify that the installation of the TimeProvider 5000 is complete, perform the
checks and procedures in Table 3-3.
Table 3-3. Installation Completeness Checklist
Operation
Complete
Ensure the TimeProvider 5000 chassis is securely attached to mounting rack
Ensure that the appropriate modules (and filler panels if needed) are installed
Verify that all power and ground wires are installed correctly and securely
Verify that all communications cables are properly installed
Verify that all input and output cables are properly installed
Applying Power to the TimeProvider 5000
The TimeProvider 5000 is not equipped with a Power switch. DC power is controlled
by a power distribution panel. After installing the unit in a rack and making the
necessary connections described in previous sections, turn on power at the
distribution panel.
Normal Power Up Indications
As the TimeProvider 5000 powers up and begins normal operation, the IOC module
and IMC module LEDs all turn on. After the module self-test is complete and the
module firmware is operational, the LED states may change to indicate the
appropriate state or status.
Table 3-4 provides a description of the module LEDs.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
51
Chapter 3 Installing the TimeProvider 5000
Applying Power to the TimeProvider 5000
Table 3-4. Module LED Descriptions
LED
Label
Description
IMC Module
Power
Module Power Indicator
PWR
Green - Module power available
Off - Module power not available
-48V A-Bus
A-Bus Battery Indicator
BT A
Off - A-Bus power connected
Red - A-Bus power not connected
-48V B-Bus
B-Bus Battery Indicator
BT B
Off - B-Bus power connected
Red - B-Bus power not connected
System Health
Aggregation of system alarms
indicator
SYS
Off - System operating normally
Amber - System operational Minor Alarm(s)
Red - System operational Major or Critical Alarm(s)
IMC Alarm
IMC module alarm/fault indicator
ALM
Off - IMC operating normally
Amber - IMC operational Minor Alarm(s)
Red - IMC operational Major/Critical Alarm(s)
Flashing Green - Software starting up
GPS Status
GPS engine communication and
antenna cable status indicator
GPS
Red - Internal GPS hardware fault
Green - GPS enabled and GPS engine/interface is
operating normally
Amber - GPS enabled and GPS engine or antenna
interface has operational issues
Off - GPS disabled
TCP/IP Management Port
LEDs on the Ethernet connector
MGMT
Left Amber Flash - Activity
Left Off - No Activity
Right Green - Link has been established
Right Off - Link has not been established
IOC Module
Power
Module Power Indicator
PWR
Green - Module power available
Off - Module power not available
Active
Indicates which IOC is responsible
for generating Telecom, 10MHz,
and 1PPS outputs
ACT
Off - Standby IOC or System Startup
Green - Active IOC
IOC Alarm
IOC module alarm/fault indicator
ALM
Off - IOC operating normally
Amber - IOC operational Minor Alarm(s)
Red - IOC has Failed or has Major/Critical Alarm(s)
Flashing Green - Software starting up
52
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 3 Installing the TimeProvider 5000
Applying Power to the TimeProvider 5000
Table 3-4. Module LED Descriptions (Continued)
LED
Label
Description
Ethernet Port 1
ETH1 port that is used for timing
distribution
ETH1
Green - Link has been established
Flashing Green - Link activity
Amber - Indicates Standby PTP port
Off - Link has not been established
Ethernet Port 2
ETH2 port that is used for timing
distribution
ETH2
Green - Link has been established
Flashing Green - Link activity
Amber - Indicates Standby PTP port
Off - Link has not been established
Local Oscillator State
Indicates the current mode of
operation of the LO servo
HOLD
Off - LO servo is operating in Locked mode
Amber - LO servo is operating in Holdover or
Acquire modes
Flashing Amber - LO servo is operating in
Warm-up mode
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
53
Chapter 3 Installing the TimeProvider 5000
Applying Power to the TimeProvider 5000
54
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 4 General Guidelines for using TimeProvider 5000
This chapter provides guidelines for using the TimeProvider 5000.
In This Chapter
Logging In And Out
Adding And Deleting Users
Saving The Present Configuration To Non-volatile Memory
Restoring Default Configuration
Determining Status
Forcing Unit To Send New Time
Configuring Static IP (default)
Configuring Dynamic IP (DHCP)
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
55
Chapter 4 General Guidelines for using TimeProvider 5000
CLI commands
CLI commands
Note: The "sync tod-source" command used in some of the following
examples forces the TimeProvider 5000 to immediately start using
the new reference for time and frequency. This command is useful in
lab tests, but its use should be carefully planned since it may cause
issues with equipment using the outputs of the TimeProvider 5000.
Logging In And Out
The default administrator user name is admin with password symmadmin**
To login:
tp5000> login
User: <user name>
Password: <password>
To logout:
tp5000> logout
Adding And Deleting Users
Only a security-level admin user can add or delete users.
Users can be added or removed with the following commands:
set user add <username>
set user delete <username>
Saving The Present Configuration To Non-volatile Memory
Use the following commands to save IMC module settings to the active IOC
memory and to save the active IOC module settings in the IMC memory:
set configuration backup imc-to-ioc
set configuration backup ioc-to-imc
Restoring Default Configuration
The user can restore the TimeProvider 5000 to Symmetricom factory default
values in two ways. The default mode preserves user login information and
system IP addresses, and is set with the following command:
set configuration default
56
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 4 General Guidelines for using TimeProvider 5000
CLI commands
The factory mode overwrites all user login information and system IP addresses,
and is set with the following command:
set configuration factory
Determining Status
show alarm (displays presently active alarms)
show gps (displays GPS information)
show inventory (according IMC and IOC cards)
show status (displays general status of unit)
Forcing Unit To Send New Time
If you change the TOD source after the unit has left warm-up, you must enter the
following command to change the time:
sync tod-source now
If you change to GPS, enter the command after the unit is ready; use the show
alarms command and check for the presence of the jam sync required alarm to
indicate readiness.
This command should also be entered after you change the time in user mode.
Configuring Static IP (default)
Example for host ip address of 192.168.0.10, with router gateway at 192.168.0.1:
set ip-mode static
set ip imc address 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1
set ip imc restart
show ip mode
(to verify change to static mode)
show ip config imc
(to verify change to IP address, gateway, and mask)
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
57
Chapter 4 General Guidelines for using TimeProvider 5000
CLI commands
Configuring Dynamic IP (DHCP)
Ethernet cable should already be connected and DHCP server configured:
set ip-mode dhcp
set ip imc restart
show ip mode
(to verify change to DHCP mode)
Switching Active And Standby Cards
Capability will be added in future release
58
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
This chapter describes the procedures for provisioning the TimeProvider 5000. Use
the procedures in this chapter after you have installed and powered up the
TimeProvider 5000 (see Chapter 3, Installing the TimeProvider 5000).
In This Chapter
Establishing a Connection to the TimeProvider 5000
Managing the User Access List
Provisioning Login Authentication
Provisioning the Ethernet Ports
Provisioning PTP
Setting the System Date Time and Time Offset
Provisioning the Input Reference
Provisioning Alarms
Routine Operation Commands
Saving and Restoring Provisioning Data
Simple Network Management Protocol
SNMP Users and Manager Addresses
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
59
Chapter 5 Provisioning
Establishing a Connection to the TimeProvider 5000
Establishing a Connection to the TimeProvider 5000
To set up and manage the TimeProvider 5000 with a terminal or a computer with
terminal emulation, you must establish either a serial connection or an Ethernet
connection. To connect through the serial port, see Communicating Through the
Serial Port, on page 60. If the TimeProvider 5000 is connected to an Ethernet LAN,
use the procedure described in Communicating Through the Ethernet Port, on page
60.
Note: Before you can communicate with the TimeProvider 5000
through an Ethernet connection, you must first configure the Ethernet
port using the serial connection.
Communicating Through the Serial Port
An EIA-232 serial port is available on the IMC module for a direct serial connection
to a terminal or a computer with terminal emulation. Use the following procedure to
connect the TimeProvider 5000 to a terminal or a computer with terminal emulation
via a straight through serial cable:
Note: For information on restricting user access, see Managing the
User Access List, on page 61.
1. Connect one end of a straight through serial cable to the serial port on the
computer or terminal and the other end to the EIA-232 connector on the IMC.
2. Configure the emulation software for 8 data bits, 1 stop bit, no parity, 57600 baud
rate, and no flow control.
3. Start the terminal emulation software and press Enter. The system prompt
should appear. If it does not, recheck each step in this procedure.
Communicating Through the Ethernet Port
To communicate with the TimeProvider 5000 using an Ethernet LAN connection,
you must first configure the Ethernet port through the EIA-232 serial port.
60
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Managing the User Access List
Configuring the Ethernet Port
Use the following procedures to configure the TimeProvider 5000 Ethernet
parameters (IP Address, Subnet Mask, and Gateway Address).
Note: The TimeProvider 5000 default IP address is 192.168.0.100,
the subnet mask is 255.255.255.0, and the gateway address is
0.0.0.0. If these defaults are acceptable, the following procedure
using the serial port is not required.
1. Establish a direct serial connection to the TimeProvider 5000 as described in
Communicating Through the Serial Port, on page 60.
2. Provision the IP, Gateway, and Subnet Mask addresses for the TimeProvider
5000. The IT department or site administrator for your location can recommend
specific addresses for these parameters. Use the dotted decimal format
xxx.xxx.xxx.xxx to enter the address parameters with the following commands:
Example
tp5000> set ip imc address 192.168.0.10 netmask 255.255.255.0
gateway 192.168.0.254 <enter>
tp5000> set ip imc restart <enter>
Connecting Through an Ethernet LAN
1. Ensure that the TimeProvider 5000 is connected to a LAN (see Communications
Connections, on page 43 for details).
2. Telnet from your computer to the IP address assigned to the TimeProvider 5000
(see Configuring the Ethernet Port, on page 61).
3. Type your user name and press Enter. If you are not assigned as a user in the
system, contact the system administrator or see Adding a User, on page 63.
4. Type your assigned password and press Enter. The system prompt appears.
Managing the User Access List
When you are logged in at the Admin level you can add, edit, or delete user names
in the user access list. The user list can contain up to 20 names and users can be
set to one of three different security levels described in Table 5-1. Users are
required to enter a user name and password to log in to the system. Users can
access or modify only the parameter settings allowed by their assigned security
level.
Caution: To avoid a possible service call, do not lose or misplace the
user name and password of the Admin-level user.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
61
Chapter 5 Provisioning
Managing the User Access List
Table 5-1. User Level and Access
Security Level
Description
User
Users can edit their password and show information, or access any
command at the User security level.
Config
Users are allowed to change configuration and issue User-level
commands.
Admin
Users are allowed to modify the security database or download new
firmware and issue commands at any level.
Use the procedures in this section to manage user access to the TimeProvider
5000.
Logging In
Use the following procedure to log in to the system at the admin level.
1. Ensure that the TimeProvider 5000 is connected to a LAN, or directly connected
to a computer through the EIA-232 serial port. See Communications
Connections, on page 43.
2. If the TimeProvider 5000 is connected to a LAN, Telnet from your computer to the
assigned IP address.
If the TimeProvider 5000 is connected to a computer directly through the serial
port, start a Terminal session and press Enter.
3. Type your user name and press Enter. The system prompts for a password.
4. Type your password and press Enter. The system prompt appears.
Note: The units default user name is admin and the default
password is symmadmin**. To avoid unauthorized access, you
should change the default user name and password.
62
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Managing the User Access List
Adding a User
Use the following procedure to add a user to the system access list.
Note:
User passwords can consist of alphanumeric characters, ~, `, (,
), !, ?, -, _, and . with a minimum of 8 characters and a
maximum of 32 characters.
Usernames can consist of numbers, upper and lower case letters,
dash "-", and underscore "_", with a maximum of 20 characters.
Usernames cannot use a leading dash - as the first character.
For a description of user access levels, see Managing the User
Access List, on page 61.
1. Login at the Admin level (see Logging In, on page 62).
2. Type show user and press Enter to view the current list of users.
3. Type set user add and press TAB twice. The system prompts you for a user
name.
4. Type a user name and press SPACE and then TAB. The name you enter will be
the log-in name for the user. The system prompts you for the access-level for the
user.
5. Type in the desire access-level (user, config, or admin) and press Enter. The
system prompts you for a password.
6. Type a password and press Enter. The password you enter will be the log-in
password for the user. The system responds with the confirm password prompt.
7. Retype the password and press Enter. The system indicates that CLI user has
been added: <user>.
8. Type show user and press Enter to verify that the account exists.
9. Repeat steps 3 through 8 of this procedure to add other users.
Deleting A User
Use the following procedure to delete user ABCD1234 from the system access list.
Do not delete the default username and password.
1. Login at the Admin level (see Logging In, on page 62).
2. Type show user and press Enter to view the current list of users.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
63
Chapter 5 Provisioning
Managing the User Access List
3. Type set user delete ABCD1234 and press Enter.
Displaying Current Users and User Access Levels
Use the following procedure to show a list of all assigned users and their access
levels.
1. Login at the Admin level (see Logging In, on page 62).
2. Type show user and press Enter. The system displays the current list of users.
Changing a Users Password and Access Level
To change a users password and access level you must delete and then re-create
the user. Use the following procedure to change the password and access level.
Note:
User passwords can consist of alphanumeric characters, ~, `, (,
), !, ?, -, _, and . with a minimum of 8 characters and a
maximum of 32 characters.
Usernames can consist of numbers, upper and lower case letters,
dash "-", and underscore "_", with a maximum of 20 characters.
Usernames cannot use a leading dash - as the first character.
For a description of user access levels, see Managing the User
Access List, on page 61.
1. Login at the Admin level (see Logging In, on page 62).
2. Type show user and press Enter to view the current list of users.
3. Type set user delete <user name> and press Enter.
4. Type set user add and press TAB twice. The system prompts you for a user
name.
5. Type a user name and press SPACE and then TAB. The name you enter will be
the log-in name for the user. The system prompts you for the access-level for the
user.
6. Type in the desire access-level (user, config, or admin) and press Enter. The
system prompts you for a password.
7. Type a password and press Enter. The password you enter will be the log-in
password for the user. The system responds with the confirm password prompt.
64
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Provisioning a RADIUS Server
8. Retype the password and press Enter. The system indicates that CLI user has
been added: <user>.
9. Type show user and press Enter to verify that the account exists.
10.Repeat Steps 3 through 9 to modify other user passwords and access levels.
Provisioning a RADIUS Server
To authenticate using RADIUS, the RADIUS server must be properly configured.
The usernames, passwords, and security level of the remotely-authenticated users
can be controlled from the RADIUS server. The TimeProvider 5000 uses the
"User-Name" attribute to determine the security level. For admin-level, use
"remote_admin". For config level, use "remote_config". For user-level, use
"remote_user".
Listed below are example configurations in the /etc/raddb/users file for the
FreeRADIUS server.
Example 1:
usr_a Auth-Type := Local, User-Password == "test"
Reply-Message = "Level 1 access granted\n",
User-Name=remote_admin
Example 2:
usr_c Auth-Type := Local, User-Password == "test"
Reply-Message = "Level 2 access granted\n",
User-Name=remote_config
Example 3:
usr_u Auth-Type := Local, User-Password == "test"
Reply-Message = "Level 3 access granted\n",
User-Name=remote_user
Provisioning Login Authentication
The authentication scheme used in the TimeProvider 5000 allows you to provision a
RADIUS server IP address and authentication key(s) for server access. If RADIUS
is enabled, the system allows local login if the server doesn't authenticate the user
and the user is configured locally.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
65
Chapter 5 Provisioning
Provisioning the Ethernet Ports
To provision the RADIUS server IP address and the authentication key for server
access:
1. Type set authentication radius server <address> and press Enter
(address is the server IP address, for example 192.168.0.10).
2. Type set authentication radius key <key> and press Enter (key is up to
32 ASCII characters).
3. Type set authentication radius enable and press Enter.
Provisioning the Ethernet Ports
The TimeProvider 5000 supports static IP addresses as well as dynamically
allocated addresses on the MGMT (Management) port. The dynamically allocated
address requires a connection to a DHCP server. When provisioning the unit for
static IP address, you can set the Host address, Mask address, and Gateway
address, or you can set the addresses to the factory default. See Appendix C,
Specifications and Factory Defaults for addresses.
Static IP Mode
Use the following procedure to configure the TimeProvider 5000 IP parameters
(Host Address, Subnet Mask, and Gateway Address) on the MGMT port. Use the
dot-decimal notation format xxx.xxx.xxx.xxx to enter the address parameter.
Example
1. Login at the Admin or Config-user level (see Logging In, on page 62).
2. Type set ip-mode static and press Enter.
3. Type set ip imc address 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1 and press Enter.
4. Type set ip imc restart.
DHCP Mode
You can either enable or disable DHCP mode on the MGMT port. Use the following
procedure to configure the TimeProvider 5000 to enable DHCP on the MGMT port.
Example
1. Login at the Admin or Config-user level (see Logging In, on page 62).
2. Type ip-mode imc dhcp and press Enter.
66
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Provisioning VLAN
3. Type set ip imc restart and press Enter.
Provisioning IOC Ethernet Ports
The Ethernet ports on an IOC card can be configured as a redundant pair or
independent ports.
Use the following procedure to configure ports on IOC 1 as a redundant pair.
1. Login at the admin or Config-user level.
2. Type set ip ioc1-1 address 192.168.2.10 netmask 255.255.255.0 gateway
192.168.2.1 and press Enter.
3. Type set redundancy port IOC1 enable and press Enter.
4. Type set ip ioc1-1 restart and press Enter.
Use the following procedure to configure the ports on IOC 1 as independent ports.
1. Login at the admin or Config-user level.
2. Type set ip ioc1-1 address 192.168.2.10 netmask 255.255.255.0
gateway 192.168.2.1 and press Enter.
3. Type set ip ioc1-1 restart and press Enter.
4. Type set ip ioc1-2 address 192.168.2.12 netmask 255.255.255.0
gateway 192.168.2.1 and press Enter.
5. Type set ip ioc1-2 restart and press Enter.
Provisioning VLAN
The TimeProvider 5000 can support up to 16 VLANs. Each VLAN must have its
own address and subnet. Use the following procedure to configure a VLAN:
1. Login at the Admin or Config-user level.
2. Type set vlan-config add ioc1-1 INDEX 1 vlan-id 2 priority 3
address 192.168.3.20 netmask 255.255.255.0 gateway 192.168.3.1 and
press Enter.
3. Type set vlan-config state ioc1-1 INDEX 1 enable and press Enter.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
67
Chapter 5 Provisioning
Provisioning PTP
4. Type set vlan-mode ioc1-1 enable and press Enter.
5. Type set ip ioc1-1 restart and press Enter.
6. Type show vlan and press Enter to verify the configuration.
Provisioning PTP
By default, PTP is enabled with unicast negotiation. If static configuration or
changes are required to the PTP configuration, please see Command Descriptions
and Communications Interface in Appendix B.
Setting the System Date Time and Time Offset
The TimeProvider 5000 Time of Day can be set either by an external source, or
manually with the Set Clock command. You can set the time and date only in the
user tod-source mode, but if the TOD source has been set to GPS (default), it is not
possible to set the time manually.
1. Login at the Admin or Config-user level (see Logging In, on page 62).
2. Type show tod-source and press Enter to check the TOD source.
3. Type set tod-source sys and press Enter.
4. Type set clock date-time <value> and press Enter. Enter the value in
format yyyy-mm-dd,hh:mm:ss.
5. Type sync tod-source now and press Enter.
Provisioning the Input Reference
When operating in normal (locked) mode, the TimeProvider 5000 uses an external
reference (such as GPS) to acquire the systems frequency and/or TOD alignment.
The TOD source must be set prior to enabling the desired interface.
68
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Provisioning the Input Reference
Setting the GPS Parameters
When the GPS reference is enabled, you can set the satellite position parameters
either automatically or manually. The GPS reference input is enabled by default. In
manual mode, you must specify the latitude, longitude, and height. You can also
specify the elevation mask which filters the satellites used by the system.
Note: Manual mode should not be used unless antenna location has
been accurately surveyed.
Example
To provision the TimeProvider 5000 to set a GPS reference for automatic mode,
perform the following steps:
1. Login at the Admin or Config-user level (see Logging In, on page 62).
2. Type show tod-source gps and press Enter to verify that the TOD source has
been set to GPS.
3. Type set tod-source gps and press Enter.
Setting the E1 Parameters
An E1 input can be configured as a frequency reference. To provision port 1 to use
2 MHz as the reference, perform the following steps:
1. Login at the Admin or Config-user level (see Logging In, on page 62).
2. Type show tod-source and press Enter to check the TOD source.
3. Type set tod-source sys and press Enter.
4. Type set io port1 input and press Enter.
5. Type set input state port1 enable and press Enter.
6. Type show tod-source and press Enter to verify the TOD source.
7. Type sync tod-source now and press Enter.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
69
Chapter 5 Provisioning
Provisioning Alarms
Provisioning Alarms
This section describes the commands used to provision and manage alarms in the
TimeProvider 5000. The user can provision the alarms to be enabled or disabled
and set thresholds to turn the alarms on and off. For a list of all alarms, see
Appendix A, System Messages.
Software commands allow you to perform the following:
Provision the severity level
Provision the alarm (enable or disable)
Show current alarm settings
Show current alarms
Display alarm status
Alarms are also indicated by LEDs on the IOC and IMC modules.
Disabling Specific Alarms
The Set Alarm Config command allows you to enabled or disabled specified alarms.
Example
To disable the GPS antenna fault alarm (alarm #64), enter the following:
1. Login at the Admin or Config-user level (see Logging In, on page 62).
2. Type set alarm-config state 64 disable and press Enter.
Showing Current Alarm Settings
The Show Alarm Config command displays the set and clear alarm thresholds for
every alarm type.
Example
To display the configuration for all alarm types, enter the following:
Type show alarm-config and press Enter.
Showing Current Alarms
The Show Alarm command displays all current alarms. To display a list of all current
alarms enter the following:
70
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Routine Operation Commands
Type show alarm and press Enter.
Displaying Alarm and Unit Status
The Show Status command displays the system status information as follows:
Assigned System Name and asset tag value
Uptime for the IMC module
System date and time
Number of standing system alarms
Active IOC module
Standby IOC module
Currently selected TOD Source
Reference Input
Clock status for each IOC module
PTP Port Configuration/State
To display the system status, enter the following:
Type show status and press Enter.
Routine Operation Commands
This section describes the commands you use to perform the following routine
operations with the TimeProvider 5000:
Displaying alarms log
Displaying events log
Displaying the TimeProvider 5000 configuration
Displaying Alarms Log
The Show Log Alarm command displays all local alarms in the alarm log in
chronological order (first in - first out).
Example
Type show log alarm and press Enter.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
71
Chapter 5 Provisioning
Saving and Restoring Provisioning Data
Displaying Events Log
The Show Log Event command displays all local events in the event log in
chronological order (first in - first out). The event log contains the 1000 most recent
alarmed and non-alarmed events.
Example
Type show log event and press Enter.
Restarting the TimeProvider 5000
The system can be restarted via the reboot system command. Since reference
output signals will be lost, it is not recommended to restart the entire system unless
required. Only the admin user can issue the reboot command. The reboot imc
command restarts the IMC card, and no output will be lost.
Example:
Type reboot imc and press Enter.
Saving and Restoring Provisioning Data
Symmetricom recommends that you keep an electronic version and/or a written
version of the provisioning changes you make to the TimeProvider 5000.
Backing up Provisioning Data
The configuration is automatically backed up one minute after a configuration
change. To backup up the current configuration immediately, enter the following:
Type set configuration backup local and press Enter.
To change the current configuration to factory default while preserving user and IP
information, enter the following:
Type set configuration default and press Enter.
To change the current configuration to the factory default, enter the following:
72
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
Simple Network Management Protocol
Type set configuration factory and press Enter.
Notes:
Setting the configuration to default will not overwrite the user login
information or the systems IP address. Setting the configuration to
factory will overwrite the user login information and return the
systems IP address to the factory set address.
Simple Network Management Protocol
This section describes the two versions of SNMP supported by the TimeProvider
5000: SNMPv2c and SNMPv3.
Note: The SNMP feature can either be ordered in a new system, or
added to a previously ordered system as a field upgrade. Contact
your Symmetricom representative for more information.
SNMP Features
The Simple Network Management Protocol (SNMP) is an application layer protocol
that allows you to manage network devices. SNMP is based on a client-server
query-response mode that requires an Ethernet connection. A manager application
(software installed on a computer) is the client generating the queries, and an agent
(software on the TimeProvider 5000) is the server generating responses. The
TimeProvider 5000 SNMP supports most existing functions.
If SNMP is present, port 161 becomes the port of standard SNMP interactive
communications and port 162 becomes the trap port.
SNMP allows you to perform the following functions:
Alarm management
GPS input configuration
TOD source configuration
SNMPv3 Security Features
SNMPv3 provides additional security features not available in SNMPv2c. In addition
to the functions of SNMPv2c, SNMPv3 allows user levels that are based on
authentication and privacy settings. The authentication protocol HMAC-SHA-1-96 is
20 characters long and the privacy protocol CBC-DES is a 16-character key. All
keys are uppercase.
The administrator can add up to 10 users to the SNMP user table.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
73
Chapter 5 Provisioning
SNMP Users and Manager Addresses
SNMP Users and Manager Addresses
SNMP CLI commands allows you to:
Enable and disable SNMP
Set SNMP manager IP address for traps
Add up to 10 SNMP user names in the SNMP user table
Display SNMP user names (read community string) and their associated access
levels
Delete SNMP user names
Enabling SNMP
SNMP is an optional feature. To enable this feature, enter the command printed on
the Symmetricom-issued certificate for this unit.
Adding a Manager IP Address
The Set SNMP Manager command allows you to specify an SNMP manager IP
address.
Example:
Use the following command to add the SNMP manager IP address
192.100.100.100 and engineID 0x12345678901234567890:
Type set snmp add manager address 192.100.100.100 engineid
0x12345678901234567890 then press Enter.
Adding and Removing SNMP Users
The Set SNMP User command allows you to add or remove users and specify
access privileges using algorithm HMAC-SH-1-96 or MD5 with the 20 character
authentication key and a CBC-DES 16 or AES character privacy key.
Example
Use the following command to add user ABC with the 20 character MD5
authentication key 123456789ABCDEFGHIJK and 16 DES character privacy key
123456789ABCDEFG.
Type set snmp add user abc securlvl private and press Enter.
Enter MD5 at the authentication protocol prompt.
74
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 5 Provisioning
SNMP Users and Manager Addresses
Enter 123456789ABCDEFGHIJK at the authentication key prompt
Enter DES at the privacy protocol prompt
Enter 123456789ABCDEFG at the privacy key prompt
Displaying SNMP Users
The Show SNMP commands allow you to display the SNMP configuration. This
includes the SNMP manager, users, trap version, trap user, and whether SNMPv2 is
enabled.
Example
Use the following command to display the list of SNMP users (user at security level
admin).
Type show snmp user and press Enter.
Note: Valid authentication key and privacy key characters include
numbers, upper and lowercase letters, and the character set :=?@_.
Do not use spaces in user names.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
75
Chapter 5 Provisioning
SNMP Users and Manager Addresses
76
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 6 Maintenance and Troubleshooting
This chapter describes maintenance and troubleshooting procedures for the
TimeProvider 5000.
In This Chapter
Preventive Maintenance
Safety Considerations
ESD Considerations
Diagnosing the IOC
Diagnosing the IMC
Repairing the TimeProvider 5000
Obtaining Technical Assistance
Upgrading the Firmware
Returning the TimeProvider 5000
Users Guide Updates
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
77
Chapter 6 Maintenance and Troubleshooting
Preventive Maintenance
Preventive Maintenance
The TimeProvider 5000 requires minimal preventive maintenance. Ensure the unit
is not exposed to hazards such as direct sunlight, open windows, water, or extreme
heat. See Environmental Requirements, on page 36, for electromagnetic
compatibility conditions that may cause damage.
Caution: To avoid electromagnetic discharge damage to the circuitry,
never attempt to vacuum the TimeProvider 5000.
Caution: To avoid damage, under no circumstances should the
interior chassis of the TimeProvider 5000 be allowed to come in
contact with water.
Table 6-1 lists preventive maintenance measures to be performed periodically. Do
not disassemble components just for the purpose of inspection.
Table 6-1. Preventive Maintenance
Item
Inspection
Corrective Action
Interval
Chassis
Inspect for dirt or foreign
material
Clean the exterior of chassis with
a soft dry cloth
Periodically
Cables
Inspect for pinched, worn or
damaged cable
Replace pinched, worn or
damaged cable at the first
opportunity
Periodically
Connectors
Inspect for loose or damaged
connector
Tighten loose connectors. If
damaged, replace the connector
and/or cable at the first opportunity
Periodically
Safety Considerations
Follow your companys safety guidelines and policies when working on or around
live equipment.
ESD Considerations
Maintenance personnel should wear ESD wrist straps when installing or working on
all TimeProvider 5000 equipment and modules. Plug the user-supplied wrist strap
into the TimeProvider 5000. Place IMC and IOC modules into static-free bags when
not in use.
78
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 6 Maintenance and Troubleshooting
Diagnosing the IOC
Diagnosing the IOC
Reading LED Conditions
Table 6-2 shows the function of the LED indicators on the IOC.
Table 6-2. LED Conditions for the IOC
Indicator
Label
Description
Power
Module Power Indicator
PWR
Green - Module power available
Off - Module power not available
Active
Indicates which IOC is
responsible for generating
Telecom, 10MHz, and
1PPS outputs
ACT
Off - Standby IOC or System Startup
Green - Active IOC
IOC Alarm
IOC module alarm/fault
indicator
ALM
Off - IOC operating normally
Amber - IOC operational Minor Alarm(s)
Red - IOC has Failed or has Major/Critical Alarm(s)
Ethernet Port 1
ETH1 port that is used for
timing distribution
ETH1
Green - Link has been established
Flashing Green - Link activity
Amber - Indicates Standby PTP port
Off - Link has not been established
Ethernet Port 2
ETH2 port that is used for
timing distribution
ETH2
Green - Link has been established
Flashing Green - Link activity
Amber - Indicates Standby PTP port
Off - Link has not been established
Local Oscillator State
Indicates the current
mode of operation of the
LO servo
HOLD
Off - LO servo is operating in Locked mode
Amber - LO servo is operating in Holdover or Acquire modes
Flashing Amber - LO servo is operating in Warm-up mode
Removing the IOC
You can remove either of two IOCs in a chassis without affecting outputs. If you
need to remove the only IOC in a chassis, or remove both IOCs from a chassis,
outputs are interrupted and will resume once one IOC has achieved normal
operating state.
Removing the IOC
To remove the IOC in a chassis, use the following procedure. Output signals will be
interrupted; they will resume once the IOC has achieved normal operating state.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
79
Chapter 6 Maintenance and Troubleshooting
Diagnosing the IOC
1. Save the contents of the IOC memory in the IMC by issuing the following
command:
Type set configuration backup ioc-to-imc and press Enter.
2. Attach a wrist grounding strap and connect it to the TimeProvider 5000 chassis.
3. Loosen the captive retaining screws and pull out on them to unseat the IOC from
the chassis.
Warning: To avoid possible electrostatic damage to the IOC, place it
in a static-free bag or on a static-free surface.
4. Place the IOC in a static-free bag or on a static-free surface.
Install a new IOC using the appropriate procedure in Replacing the IOC, on page
80.
Replacing the IOC
This section contains procedures for replacing IOC in three circumstances:
Replacing the only IOC in a chassis
Replacing one of two IOCs in a chassis
Replacing both IOCs in a chassis
Replacing the IOC
To replace the IOC in a chassis, use the following procedure. Output signals will
resume once the IOC has achieved normal operating state. This procedure
assumes that you have stored the contents of the IOC memory in the IMC using the
Set Configuration Backup command.
1. Attach a wrist grounding strap and connect it to the TimeProvider 5000 chassis.
2. Install the IOC into the chassis and tighten the captive retaining screws.
3. Copy the contents of the IOC memory stored in the IMC by issuing the following
command.
Type set configuration restore ioc and press Enter.
If you have not stored the contents of the IOC memory in the IMC, then provision
the IOC using the procedures and commands described in Chapter 5, Provisioning.
4. Wait for the IOC to reboot and achieve normal operating state.
80
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 6 Maintenance and Troubleshooting
Diagnosing the IMC
Diagnosing the IMC
Reading LED Conditions
Table 6-3 shows the function of the LED indicators on the front panel of the IMC.
Table 6-3. LED Conditions for the IMC
Indicator
Label
Description
Power Indicator
(IOC and IMC)
PWR
Green - Module power available
Off - Module power not available
-48V A-Bus
A-Bus Battery
Indicator (IMC)
BT A
Off - A-Bus power connected
Red - A-Bus power not connected
-48V B-Bus
B-Bus Battery
Indicator (IMC)
BT B
Off - B-Bus power connected
Red - B-Bus power not connected
System Health
Aggregation of
system alarms
indicator
SYS
Off - IMC, IOC operating normally
Amber - IMC, IOC operational Minor Alarm(s)
Red - IMC, IOC operational Major or Critical Alarm(s)
IMC Alarm
IMC module
alarm/fault
indicator
ALM
Off - IMC operating normally
Amber - IMC operational Minor Alarm(s)
Red - IMC operational Major/Critical Alarm(s)
GPS Status
GPS engine
communication
and antenna cable
status indicator
GPS
Red - Internal GPS hardware fault
Green - GPS enabled and GPS engine/interface is operating
normally
Amber - GPS enabled and GPS engine or antenna interface has
operational issue
Off - GPS disabled
TCP/IP
Management Port
LEDs on the
Ethernet
connector
MGMT
Left Amber Flash - Activity
Left Off - No Activity
Right Green - Link has been established
Right Off - Link has not been established
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
81
Chapter 6 Maintenance and Troubleshooting
Repairing the TimeProvider 5000
Replacing the IMC
Caution: You must disconnect the GPS antenna cable before
removing the IMC module.
You can remove the IMC from the chassis and replace it without affecting outputs.
1. Save the contents of the IMC memory in an IOC (example is for IOC1) by issuing
the following command:
Type set configuration backup imc-to-ioc1 and press Enter.
2. Attach a wrist grounding strap and connect it to the TimeProvider 5000 chassis.
3. Remove the IMC by loosening the captive screws and pulling the IMC from the
chassis.
Warning: To avoid possible electrostatic damage to the IMC, place it
in a static-free bag or on a static-free surface.
4. Place the IMC in a static-free bag or on a static-free surface.
5. Insert another IMC into the chassis and tighten the captive screws.
6. Reload the IMC memory from the IOC by issuing the following command:
Type set configuration restore imc-to-ioc1 and press Enter.
Repairing the TimeProvider 5000
Repairing the TimeProvider 5000 is limited to replacing modules. Refer to Working
With Modules, on page 42, for information on how to properly handle modules to
prevent electrostatic or physical damage.
Each power module in the TimeProvider contains a 3A fuse, but these fuses are not
field-replaceable. There are no field-serviceable fuses in the TimeProvider 5000. If a
fuse blows in a TimeProvider 5000, the unit must be returned to the factory for
repair.
To remove an IOC, loosen the captive screws and pull the module out of the
chassis. Place the module on an anti-static surface or in an anti-static bag.
82
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 6 Maintenance and Troubleshooting
Obtaining Technical Assistance
To remove the IMC, loosen the captive screws and pull the module out of the
chassis. Place the module on an anti-static surface or in an anti-static bag.
Warning: To avoid possible electrostatic damage to the module or
panel, place it in a static-free bag or on a static-free surface.
Obtaining Technical Assistance
If you have technical questions about the TimeProvider 5000, call Symmetricom
Global Services (SGS) at 888-367-7966 (toll-free in USA only), 408-428-7907, or
+49 700 3288 6435 in Europe, Middle East, or Africa. You can also E-mail your
technical questions to
[email protected] or
[email protected].
Upgrading the Firmware
You can upgrade the firmware in the IMC, IOC, or redundant IOCs using CLI
commands and software available from Symmetricom. Only users with Admin level
access can execute the command. The command places the IMC in the firmware
download mode and prevents all other sessions from making changes to the
configuration. During the upgrade process, no new sessions are allowed. Refer to
Appendix B, Command Descriptions and Communications Interface and the
command Upgrade, on page 164 for details on the upgrade process.
Caution: To avoid a possible service call, do not issue a command to
the TimeProvider 5000, do not remove power from the TimeProvider
5000, and do not remove an IOC or IMC from the chassis during the
upgrade process. Doing so could corrupt the flash memory in a
module, disabling the TimeProvider 5000.
Upgrading the IOC
The Upgrade command allows you to install firmware in a single IOC in basic
configuration, or in either IOC of a redundant configuration. This section contains
procedures for upgrading a chassis with a single IOC and for upgrading a chassis
with redundant IOCs.
Upgrading IOCs
To upgrade the software in an IOC, use the procedure in this section. Outputs from
the TimeProvider 5000 are interrupted for up to 30 minutes until the upgraded IOC
enters the Locked mode.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
83
Chapter 6 Maintenance and Troubleshooting
Upgrading the Firmware
1. Login at the Admin level (see Logging In, on page 62).
2. Type set configuration backup local and press Enter to save the contents
of the IOC configuration. The alternate is set configuration backup
ioc-to-imc.
3. Type upgrade ioc <filename> <ftp-server><user name> (for example,
upgrade ioc ver2.bin ftp:192.168.5.64) and press Enter. The user is then
prompted for the user name and password for the server.
Note: The system will FTP the file from the specified FTP server (IP
or name) and then upgrade the module.
Note: If an SFTP server is used, the protocol does not need to
be included with the address.
ftp:192.168.5.64
[sftp:]192.168.5.64
4. The new software is loaded into the IOC, after which it is rebooted and enters the
Warm-up mode for up to 30 minutes.
5. Type set configuration restore ioc-from-imc and press Enter to restore
the contents of the IOC configuration. This step is not necessary if the
configuration is backed up to local.
Upgrading the IMC
To upgrade the software in the IMC, use the following procedure:
Note: Outputs are not affected during the IMC upgrade
procedure.
1. Login at the Admin level (see Logging In, on page 62).
2. Type set configuration backup local and press Enter to save the contents
of the IMC configuration. The alternate is set configuration backup
imc-to-ioc
3. Type upgrade imc <filename> <ftp-server> <user name> (use the IP
address or server name) and press Enter.
4. When prompted, enter a user name and password for the server.
84
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Chapter 6 Maintenance and Troubleshooting
Returning the TimeProvider 5000
Note: The system will FTP the file from the specified FTP server (IP
or name) and then upgrade the module.
5. Type set configuration restore imc-from-ioc and press Enter to restore
the contents of the IMC configuration. This step is not necessary if the
configuration is backed up to local.
6. The TimeProvider 5000 validates the received file, and if the file is valid it
updates the flash memory and reboots the IMC.
Note: If the file is not valid, the TimeProvider 5000 will reject it.
Returning the TimeProvider 5000
You should return the equipment to Symmetricom only after you have exhausted the
troubleshooting procedures described earlier in this chapter, or if Symmetricom
Global Services has advised you to return the unit.
Note: Please retain the original packaging for re-shipping the
product. If the original packaging is not available, contact
Symmetricom Global Services (SGS) for assistance.
Repacking the Unit
Return all units in the original packaging. If the original packaging is not available,
contact Symmetricom Global Services. Use standard packing procedures for
products being returned for repair to protect the equipment during shipment.
Connectors should be protected with connector covers or the equipment should be
wrapped in plastic before packaging. Ensure that the display and connectivity
panels are protected when packaged.
Equipment Return Procedure
To return equipment to Symmetricom for repair:
1. Call Symmetricom Global Services (SGS) at 888-367-7966 (toll-free in USA
only), 408-428-7907, or +49 700 3288 6435 in Europe, Middle East, or Africa to
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
85
Chapter 6 Maintenance and Troubleshooting
Users Guide Updates
obtain a return material authorization number (RMA) before returning the product
for service.
You can request an RMA on the internet at
www.symmetricom.com/Support/req_repair.htm.
Retain the assigned RMA number for future reference.
2. Provide a description of the problem, product item number, serial number, and
warranty expiration date.
3. Provide the return shipping information (customer field contact, address,
telephone number, and so forth.)
4. Ship the product to Symmetricom, transportation prepaid and insured, with the
Return Material Authorization (RMA) number and item numbers or part numbers
clearly marked on the outside of the container to the address given with the RMA.
Repaired equipment is returned to you with shipping costs prepaid by
Symmetricom.
Users Guide Updates
When this manual is updated the updated version will be available for downloading
from Symmetricoms internet web site. Manuals are provided in PDF format for ease
of use. After downloading, you can view the manual on a computer or print it using
Adobe Acrobat Reader.
Manual updates are available at:
www.symmetricom.com
Note: If you are downloading a product manual for the first time, you
will need to register with Symmetricom for a username and password.
If you are currently registered, login and download the manual
update.
86
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix A System Messages
This section provides information about the system messages that are displayed in
response to a provisioning event or to an alarm that occurs when an associated
threshold or timer is outside of the provisioned setting.
In This Appendix
Message provisioning
System Notification Messages
System State and Status Change Notifications
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
87
Appendix A System Messages
Message provisioning
Message provisioning
The TimeProvider 5000 supports logging of events using Syslog defined facility and
severity codes and system defined facility codes as follows:
Facility codes
0 kernel messages
1 User-level messages
3 System daemons
4 Security/authorization messages
5 Messages generated internally by syslogd
9 Clock daemon
11 FTP daemon
20 Time Provider 5000 Messages (events and alarms)
21 TimeProvider 5000 Command Response
Severity codes
0 (critical) Emergency: system is unusable
1 (critical) Alert: action must be taken immediately
2 (critical) Critical: critical conditions
3 (major) Error: error conditions
4 (minor) Warning: warning conditions
5 (event) Notice: normal but significant condition
6 (event) Informational: informational messages
88
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix A System Messages
Message provisioning
Notes:
1. Severity codes, 0, 1, 2, 3, and 4, are also indicated by the Alarm
LED(s) on the IMC and IOC modules.
2. Severity Code 0, 1, and 2 indicate Critical Alarms.
3. Severity Code 3 indicates Major Alarms.
4. Severity Code 4 indicates Minor Alarms.
5. Severity Code 5 and 6 are not associated with an Alarm Level.
The syslog message format is as follows:
Mmm dd hh:mm:ss
host_machine,Event/AlarmID,MsgTypel,MsgID,MsgText
Where:
Mmm = Month dd = date hh:mm:ss = system time
host_machine = hostname
AlarmID = 000 thru 128
EventID = 128 thru 255
MsgType = Event | Minor | Major | Critical (defined by severity code)
MsgID = SNMP message ID (facility code+severity code)
MsgText = (see tables)
The following is an example syslog message showing Input Port 1 state being set to
Disabled:
Aug 19 21:23:12 TP5000 I/O,196,Event,215, Input Port 1 state is
set to disabled
Syslog messages are stored according to Message IDs in the following log files:
35, 44, and 45 are stored in the Security Log in the following format:
Mmm dd
hh:mm:ss host_machine OS defined Security Issue Message
200 through 204 are stored in the Alarm Log
205 and undefined IDs are stored in the Event Log
215 is stored in the Command Log in the following format:
Mmm dd
hh:mm:ss host_machine,MsgTypel,MsgID,MsgText
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
89
Appendix A System Messages
System Notification Messages
System Notification Messages
Table A-1 provides a list of system notification messages. These messages are
logged and sent to a remote syslog server if configured. Alarms will also generate
an SNMP trap.
Table A-1. System Notification Messages
Description
CompID EventID MsgLevel
Communication to IMC/IOC
peer card failed
Critical
MsgText
Corrective Action
Communication to
<card> failed
Troubleshoot any
existing system alarms
Communication to
<card> restored
None required
GPS engine
communications
failed
IMC
Minor
Check for any system
GPS engine
communications failed alarms and rectify as
needed
GPS engine
None required
communications
restored
GPS engine not
tracking satellite
IMC
Minor
GPS engine not
tracking satellite
Check antenna and
connections
GPS engine tracks
satellite
None required
TOD source <source>
invalid
Troubleshoot TOD
source
TOD source <source>
valid
None required
TOD source
invalid
IMC
Major
TOD has been set IMC
by TOD source
Event
TOD has been set by
<source>
None required
IMC time has
been updated
IMC
Event
IMC time has been
updated
None required
Management port IMC
link down
Minor
Management port link
down
Check network
connections
Management port link
up
None required
90
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
Ethernet port
(ETH1 or ETH2)
link down
CompID EventID MsgLevel
IOC
Minor
MsgText
Corrective Action
<port> port link down
Check network
connections
<port> port link up
None required
Manual sync IOC IMC
time to IMC
required
Power out of
range
GPS antenna
voltage out of
range
GPS antenna
current out of
range
GPS antenna
short-circuit
IMC/IOC
IMC
IMC
IMC
10
11
12
098-00028-000 Revision A December, 2008
Minor
Major
Major
Major
Minor
Manual sync IOC time
to IMC required
Sync IOC time to clear
alarm
Synced IOC time to
IMC
None required
<x.x V> power out of
range (voltage value)
Hardware failure Replace module
<x.x V> power within
range (voltage value)
None required
GPS antenna voltage
out of range (voltage
value)
Check antenna
connections
GPS antenna voltage
within range (voltage
value)
None required
GPS antenna current
out of range (current
value)
Check all cable and
antenna connections,
check voltage
suppressor
GPS antenna current
within range (current
value)
None required
GPS antenna
short-circuit (voltage
value)
Check all cable and
antenna connections,
check voltage
suppressor
GPS antenna
short-circuit cleared
(voltage value)
None required
TimeProvider 5000 Users Guide
91
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
GPS antenna
open-circuit
CompID EventID MsgLevel
IMC
13
Minor
MsgText
GPS antenna
open-circuit (current
value)
Corrective Action
Check all cable and
antenna connections,
check voltage
suppressor
None required
GPS antenna opencircuit cleared (current
value)
Battery(-48V)-A
failure
IMC
14
Major
Battery (-48V) -A failure Troubleshoot the -48V
power supply. Check
voltage supply to A side
of shelf
Battery (-48V) -A failure None required
cleared
Battery(-48V)-B
failure
IMC
15
Major
Battery (-48V) -B failure Troubleshoot the -48V
power supply. Check
voltage supply to B side
of shelf
Battery (-48V) -B failure None required
cleared
FPGA access
failure
Flash memory
failure
PLL unlock error
Internal
communication
error
92
IMC/IOC
IMC/IOC
IMC
IOC
TimeProvider 5000 Users Guide
16
17
18
19
Critical
Critical
Critical
Critical
FPGA access failure
Hardware fault
-Replace module
FPGA access failure
cleared
None required
Flash memory failure
Hardware fault
-Replace module
Flash memory failure
cleared
None required
PLL unlock error
Reboot System - If
alarm remains, replace
module
PLL unlock error
cleared
None required
Internal communication Reboot System - If
alarm remains, replace
error
module
Internal communication
None required
error cleared
098-00028-000 Revision A December, 2008
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
FPGA
temperature
exceed limit
CompID EventID MsgLevel
IOC
IOC detected but IMC
none of them
active
Module reboot
IMC/IOC
IOC
RTE
communication to
peer error
20
21
Minor
Major
MsgText
Corrective Action
FPGA temperature
exceed limit
Check room
temperature setting.
FPGA temperature
exceed limit cleared
None required
IOC detected but none
of them active
Reboot system
Active IOC detected
None required
None required
22
Event
Module reboot
23
Major
RTE communication to Reboot System - If
peer error
alarm remains, replace
IOC module
RTE communication to None required
peer error restored
Entered warmup
mode
Entered freerun
mode
IOC
IOC
Entered fast-track IOC
mode
Entered
normal-track
mode
IOC
24
25
26
27
098-00028-000 Revision A December, 2008
Minor
Event
Event
Event
Entered warmup mode None required - If still
present after 30 min.
check other system
alarms
Transitioned out of
warmup mode
None required
Entered freerun mode
If freerun mode not
desired, check system
input reference
Transitioned out of
freerun mode
None required
Entered fast-track
mode
None required
Transitioned out of
fast-track mode
None required
Entered normal-track
mode
None required
Transitioned out of
normal-track mode
None required
TimeProvider 5000 Users Guide
93
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
Entered bridging
mode
CompID EventID MsgLevel
MsgText
Corrective Action
IOC
28
Event
Entered bridging mode Check input system
reference
Transitioned out of
bridging mode
None required
Entered holdover IOC
mode
29
Minor
Entered holdover mode Check input system
reference
Transitioned out of
None required
holdover mode
In holdover mode IOC
for extended
period
30
Major
In holdover mode for
extended period
Check input system
reference
Transitioned out of
extended holdover
mode
None required
Operational failure
Check system alarmstroubleshoot as
required to determine
recommended action
Operational
failure
Input active
IOC-to-IOC sync
fault
IMC/IOC
IOC
IOC
Input disqualified IOC
as possible
reference
31
32
33
34
Critical
Event
Major
Minor
Operational failure
cleared
None required
<input> active
None required
<input>inactive
Check state of input
port
IOC-to-IOC sync fault
Hardware fault
-Replace module
IOC-to-IOC sync fault
cleared
None required
<input> disqualified as Check system input
reference
system reference
<input> disqualification None required
cleared
Input failed due to IOC
LOS
35
Minor
<input> loss of signal
<input> loss of signal
cleared
94
TimeProvider 5000 Users Guide
Check system input
reference
None required
098-00028-000 Revision A December, 2008
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
CompID EventID MsgLevel
Input phase error IOC
Input IPLL not
settled
Input frequency
error
IOC
IOC
36
37
38
Minor
Minor
Minor
MsgText
Corrective Action
<input> phase error
Check system input
reference
<input> phase error
cleared
None required
<input> IPLL not
settled
Check system input
reference
<input> IPLL settled
None required
<input> frequency error Check system input
reference
<input> frequency error None required
cleared
Input failed due to IOC
OOF
Input failed due to IOC
AIS
PTP server near IOC
maximum packet
limit
39
40
41
Minor
Minor
Minor
<input> out of frame
Check system input
reference
<input> out of frame
cleared
None required
<input> alarm
indication signal
Check system input
reference
<input> alarm
indication signal
cleared
None required
PTP server exceeded Reduce number of
<x%> of packet limit on clients or client request
rate
ETHx
PTP server near packet None required
limit cleared on ETHx
PTP server
reached
maximum client
limit
IOC
42
Minor
PTP server exceeded
<x%> of client limit on
ETHx
Increase number of
clients allowed or
reduce number of
clients total
PTP server near client
limit cleared on ETHx None required
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
95
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
PTP client is
unreachable
CompID EventID MsgLevel
IOC
43
Event
MsgText
PTP client with IP
<0.0.0.0> is
unreachable
Corrective Action
Check IP address for
correct configuration,
possible network
problems. Check for
client down- if yes,
enable client
None required
PTP client with IP
<0.0.0.0> is reachable
Hardware
IMC/IOC
incompatible with
software
IMC-IOC
Software
incompatible
IOC-IOC
Software
incompatible
IMC/IOC
IOC
44
45
46
Minor
Minor
Minor
Hardware incompatible Software upgrade
required
with software
Hardware compatible
with software
None required
IMC-IOC Software
incompatible
Software upgrade
required
IMC-IOC Software
compatible
None required
IOC-IOC Software
incompatible (0)
Software upgrade
required
IOC-IOC Software
compatible (0)
None required
IOC installed
IOC
47
Event
<IOC> present
None required
IOC removed
IOC
48
Event
<IOC> not present
Check IOC slot in shelf
for module
No IOC installed
IOC
49
Minor
No IOC installed
Check IOC slot in shelf
for module
At least one IOC
installed
None required
None required
Transitioned to
active state
IOC
50
Event
Transitioned to active
state
Transitioned to
standby state
IOC
51
Event
Transitioned to standby None required
state
96
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Description
Input software
loop not settled
Input PPS Loss
CompID EventID MsgLevel
IOC
IMC/IOC
52
53
Minor
Critical
MsgText
Corrective Action
<input> software loop
not settled
Check system input
reference
<input> software loop
settled
None required
Input PPS loss
Hardware fault- replace
IOC first - If alarm is still
present, replace IMC
Input PPS loss cleared None required
User
IMC/IOC
configuration lost
54
Event
User configuration lost Reconfigure system
then backup
None required
User configuration
restored
55
Minor
Primary image failed. Image in primary
Running backup image partition of flash
corrupted. Run
upgrade to recover the
image
IMC
Production
configuration data
error
56
Critical
Production
Hardware failureconfiguration data error replace module
Direct access
image error. Use
JFFS2 image
IMC
57
Minor
Direct access image
error. Use JFFS2
image
Direct access image
corrupted. Run
upgrade to recover the
image
IMC-IOC FPGA
link failed
IMC/IOC
58
Critical
IMC-IOC FPGA link
failed
Hardware failurereplace module
IMC-IOC FPGA link
failure cleared
None required
Excessive traffic on
ETHx
Check traffic level on
network
Excessive traffic
cleared on ETHx
None required
Primary image
failed. Running
backup image
Excessive traffic
on Ethernet port
IMC/IOC
IOC
59
098-00028-000 Revision A December, 2008
Minor
TimeProvider 5000 Users Guide
97
Appendix A System Messages
System State and Status Change Notifications
Table A-1. System Notification Messages (Continued)
Description
CompID EventID MsgLevel
Unsupported SFP IOC
on Ethernet port
Input poor SSM
IOC
60
61
Minor
Minor
MsgText
Corrective Action
Unsupported SFP on
ETHx
Replace SFP with
Symmetricom
approved SFP listed in
User Guide
Unsupported SFP
cleared on ETHx
None required
<input> poor SSM
Check system input
reference quality level
<input> poor SSM
cleared
None required
None required
Input SSM
changed
IOC
62
Event
Input SSM changed
Input GPS not
tracking
IOC
63
Minor
Input GPS not tracking Check GPS antenna
location, cable
connections
Input GPS not tracking None required
cleared
Input GPS RGP
data loss
IOC
64
Minor
Input GPS RGP data
loss
Input GPS RGP data
loss cleared
This alarm could occur
during configuration. If
the alarm still present 1
minute after
configuration, reboot
system. If alarm still
present, replace IOC
module
None required
System State and Status Change Notifications
Table A-2 provides a list of system provisioning messages. These messages are
logged and sent to a remote syslog server if configured.
98
TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix A System Messages
System State and Status Change Notifications
Table A-2. System Provisioning Messages
Action
MsgText
Command Syntax Error
Invalid Command
Invalid Parameter
Alarm Set Delay
Alarm # Set Delay has been set to value
Set Bridging Time
Bridging time has been set to value
IOC Module State
IOC # has been set to Active
IOC # has been set to Standby
IOC # has been set to Disabled
Time set
Date has been set to value
Time has been set to value
Local time offset has been set to value
GPS to TAI time offset is value
UTC to TAI time offset is value
PTP timescale set to value
System Configuration
Saved/Restored
System configuration has been backed-up
System configuration has been restored
System configuration has been saved to user defaults
System configuration has been set to user defaults
System configuration has been set to factory defaults
Log file size
logfiletype log size has been set to size
User Message
user message goes here
IMC Hostname
Hostname has been set to value
IMC Firewall Configuration
Firewall state has been set to state on daemon_name
IMC IP Configuration
IMC Host IP address has been set to ip_address
IMC Host Mask has been set to ip_address
IMC Host Gateway has been set to ip_address
IMC Broadcast address has been set to ip_address
IMC IP-mode has been set to value
IMC SNMP Management
SNMP manager host has been set to ip_address
SNMP manager port has been set to udp_port
SNMP agent port host has been set to udp_port
SNMP user has been added
SNMP user has been deleted
IMC User Management
User has been added
User has been modified
User has been deleted
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide
99
Appendix A System Messages
System State and Status Change Notifications
Table A-2. System Provisioning Messages (Continued)
Action
MsgText
Intra-System Communication
Configuration
Intra-system addresses have been set to Class #
RADIUS Configuration
RADIUS mode has been set to mode [, ip_address]
RADIUS key has been set
Remote Syslog
Remote Syslog set to ip_addr | hostname
Remote System at ip_addr | hostname is value
Reboot
IMC module reboot requested by user
IOC# module reboot requested by user
Upgrade System Firmware
Firmware upgrade successful to version
Firmware upgrade unsuccessful
Active Image Set
Active image set to value
User Login/Logout
username logged in
username logged out
IOC IP Configuration
IOCx Host IP address has been set to ip_address
IOCx Host Mask has been set to ip_address
IOCx Host Gateway has been set to ip_address
IOC State
IOCx state has been set to value
Reboot
IMC module reboot requested by user
IOC# module reboot requested by user
Upgrade System Firmware
Firmware upgrade successful to version
Firmware upgrade unsuccessful
Active Image Set
Active image set to value
GPS Configuration
GPS Position mode has been set to value
GPS Position has been set to lat, long, height
GPS Position mask has been set to value
GPS Antenna Cable Delay has been set to value
Input State
GPS port state has been set to value
Input Port # state has been set to value
PTP Common Configuration
PTP Address Mode has been set to value
PTP Clock ID has been set to value
PTP Bonding has been set to value
PTP Module Redundancy has been set to value
100 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix A System Messages
System State and Status Change Notifications
Table A-2. System Provisioning Messages (Continued)
Action
MsgText
PTP Unicast Configuration
PTP Unicast Negotiation has been set to value
PTP Dynamic Lease Interval has been set to value
PTP Static Unicast Range # [1-10] has been set to value
PTP Static Unicast Priority 1 has been set to value
PTP Static Unicast Priority 2 has been set to value
PTP Static Unicast Domain has been set to value
PTP Static Unicast Sync Message Rate has been set to value
PTP Static Unicast Announce Timeout has been set to value
PTP Static Unicast Delay Response has been set to value
PTP Static Unicast PDelay Response has been set to value
PTP Unicast VLAN State has been set to value
PTP Unicast VLAN ID &Priority has been set to value
PTP Unicast Diffserv State has been set to value
PTP Unicast DSCP has been set to value
Telecom I/O Port
Configuration
I/O Port # configured as value
Input Port Configuration
Input Port # State is set to value
Input Port # Priority is set to value
Input Port # Frame Type is set to value
Input Port # CRC is value
Input Port # SSM is value
Input Port # SSM Bit is set to value
Input Port # PQL Value is set to value
Input Port # ToD Pair is set to value
Input Port # is the manually selected reference
Output Port Configuration
Output Port # State is set to value
Output Port # Frame Type is set to value
Output Port # CRC is value
Input Port # SSM is value
Output Port # SSM Bit is set to value
Output Port # will turn-on during value
10 MHz Output Port
Configuration
10 MHz Output State is set to value
10 MHz Output will turn-on during value
1 PPS Output Port
Configuration
1 PPS Output State is set to value
1 PPS Output will turn-on during value
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 101
Appendix A System Messages
System State and Status Change Notifications
102 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications
Interface
This appendix describes the CLI command conventions, the prompts, line editing
functions, and command syntax. The CLI command functions and features are
organized by user security access levels and are listed alphabetically.
In This Appendix
CLI Overview
TimeProvider 5000 CLI Command Set
Simple Network Management Protocol
Secure Shell Protocol
Secure File Transfer Protocol
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 103
Appendix B Command Descriptions and Communications Interface
CLI Overview
CLI Overview
The Command Line Interface (CLI), also called the ASCII command set, can be
used to control the TimeProvider 5000 from a terminal connected to the EIA-232
serial port, or the Ethernet port.
Figure B-1.
TimeProvider 5000 CLI Command Set
TimeProvider 5000 CLI Command Conventions
The following are conventions used for the TimeProvider 5000 CLI command set .
104 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
CLI Overview
Commands are case sensitive
{ } Braces indicate more than one parameter data option. When entering
options in the CLI command, enter one option from those available within the
braces. Options within braces { } are separated by a pipe ( | ).
[ ] Brackets provide information about the allowed range. The first value is the
minimm, and the last value is the maximum.
Bold highlights keywords in the command syntax
Italics indicate variable options.
CLI Command Keyboard Usage
You must press the SPACE key, and then press the TAB key after entering a CLI
command. Also, after entering a command, you may see <enter>. This is a
prompt for you to press ENTER to execute the command that you entered.
The interface has built-in features for navigating within the CLI command
hierarchy, which are as follows:
The TAB key can be used at any time while typing a command (including at the
prompt) to provide continuation options. Press the TAB key to display a list of the
available commands. Press the TAB key at any time while typing a command
TimeProvider 5000 will respond with the completion of the keyword or available
completion choices based on the letters you typed.
The ? (SHIFT+QUESTION MARK) accesses the CLI online help. It can be used
at any time while typing a command (including at the prompt) to provide
continuation options. These options include brief descriptions of commands, or
data type, format, and range.
If typing of a keyword is partially complete, the completion will display if it is
unique, otherwise, the completion choices will be available.
If the keyword is complete, and you press the TAB key or ? (SHIFT+QUESTION
MARK), the choices for the next syntax element will display.
In the following example, if you press the TAB key, or the ?
(SHIFT+QUESTION MARK), after typing s, the CLI commands set,
set-timeout, show, and sync display.
Typing s at the prompt:
tp5000> s
Then pressing the TAB key :
set
set-timeout
show
sync
Or pressing the ? (SHIFT+QUESTION MARK)will display the available
commands that start with s (for this example) and brief descriptions of those
commands:
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 105
Appendix B Command Descriptions and Communications Interface
CLI Overview
set
-Set TP5000 information or setting
show
-Display TP5000 information or setting
sync
-Synchronize the TOD source
set-timeout
-Set the inactivity timeout to the defined seconds
Previously typed commands can be recalled by using the UP ARROW key. You
can recall up to five previously typed commands. Continually pressing the UP
ARROW key will cycle you through the five previously typed commands. After
pressing the UP ARROW key five times, you will go back to the last command
you previously typed. Use the DOWN ARROW key to cycle the five prior typed
commands in the opposite direction.
You can use the BACKSPACE to correct keystroke errors, or to reuse parts of a
previously typed command. When using BACKSPACE, the removed characters
will still appear on the screen, but they have been removed to the position shown
by the cursor. When you start typing, the removed characters are overwritten.
Command Line Format
The command line format is as follows:
[Verb] Command [Parameter] [Data] EOL
Verb - the type of action to be taken with the command.
Set - enables you to provision a defined parameter.
Show - enables you to display the provisioned state of a parameter.
Parameter - command input that defines the particular command element to be
shown or modified.
Data - the data input for the parameter.
EOL - this parser responds only to <CR Return>. When the parser receives
<CR Return>, the input is terminated, and the command line entry is processed.
Command User Levels
The TimeProvider 5000 provides a hierarchy of CLI command user levels that
permit an increasing level of access to system parameters. This allows the system
administrator to add users who can only view but not change system parameters
and users who can view and change system parameters.
The users assigned to each security level have access options available as follows:
Level 1 - user class, with read-only rights
Level 2 - config user class, with read-write rights
106 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Level 3 - administrator user class, with read-write rights and can also configure
users and upgrade firmware
TimeProvider 5000 CLI Command Set
This section provides an alphabetical listing and details of all CLI commands.
Show Alarm
Displays the system's standing (active) alarms and events.
Level 1:
show {alarm | event}
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks: The information displayed is expected to be identical to an entry in the
Event/Alarm Log File.
Related: show status, show alarm-threshold, set alarm-threshold,
show alarm-state, set alarm-state
Show Alarm-config
Displays the alarm level, set, and clear alarm delay time for the specified alarms.
Level 1:
show alarm-config
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks:
Related: set alarm-config
Set Alarm-config
Provisions the alarm level, set, and clear alarm delay time for the specified alarms.
Level 1:
Not Applicable
Level 2:
set alarm-config state {alarm # | all} {enable | disable}
set alarm-config level [alarm # | all] value
set alarm-config delay [alarm # | all] [set] value
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 107
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Provisions the state of the specified alarm.
Provisions the Level of the specified Alarm # to the a value of 0 thru 6
0 - Emergency: system is unusable - critical
1 - Alert: action must be taken immediately - critical
2 - Critical: critical conditions - critical
3 - Error: error conditions - major
4 - Warning: warning conditions - minor
5 - Notice: normal but significant condition - event
6 - Informational: informational messages - event
Provisions the Delay of the specified Alarm # to a value of 5 thru 500000 (seconds).
Level 3:
Same as Level 2
Remarks: The alarm is disabled if either threshold, set or clear, is set to zero.
Related: show alarm-threshold
108 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Alias
This command will display defined aliases. It will also allow the user to add an alias
for a command.
Level 1:
alias
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Example:
tp5000> alias TP5000 ATC
tp5000> alias
alias
TP5000='ATC'
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 109
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Authentication
Displays how the system authenticates users.
If applicable, displays RADIUS server IP address or hostname and key.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
show authentication
Remarks: Authentication can be local or RADIUS
Related: set authentication
Example:
tp5000> show authentication <enter>
Radius server addr
Radius server key
Radius server state
- 0.0.0.0
- none
- disable
Set Authentication
Provisions the authentication source for user logins.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
set authentication radius {enable | disable}
Provisions the specified state for RADIUS authentication.
set authentication radius ip_addr key_value
Provisions the RADIUS server IP address or hostname and key.
Remarks: Only one server is supported. Only one key is supported.
Related: show authentication
110 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Auto-sync
Displays the auto sync state
Level 1:
show auto-sync
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks:
Related: set auto-sync
Example:
tp5000> show auto-sync <enter>
AUTO-SYNC
- enable
Set Auto-sync
Provisions the auto sync state
Level 1:
Not Applicable
Level 2:
set auto-sync {enable | disable}
Level 3:
Same as Level 2
Remarks:
Related: show auto-sync
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 111
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Bridge-time
Displays the bridging time that is used to allow the frequency servo to coast through
short periods when the system does not have qualified reference.
Level 1:
show bridge-time
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks: If the system has not qualified a ToD Source (frequency reference) within
the specified bridging time the system transitions into holdover mode of operation.
Related: set bridge-time
Set Bridge-time
Provisions the amount of time, in seconds, the system remains in bridging mode
before transitioning into the holdover mode of operation.
Level 1:
Not Applicable
Level 2:
set bridge-time value
Level 3:
Same as Level 2
Remarks:
Related: show bridge-time
112 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Clock
Displays the date, time, local time offset, and leap seconds in several formats.
Level 1:
show clock
Displays the following:
1) the current local time as a date, time, and local time offset
2) the current UTC time as a date and time
3) the accumulated leap seconds between TAI and UTC time.
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks:
Related: set clock
Example:
tp5000> show clock
IMC time: 2008-11-19 02:02:01
IOC time: 2008-11-19 02:02:01
Leap sec: 33
Leap pend: +1 at end of 2008-12-31
Set Clock
Provisions the user-assigned Date, Time, and accumulated leapseconds. The TOD
source must be set to the system mode with the set tod-source sys command in
order to change any clock settings.
Level 1:
Not Applicable
Level 2:
set clock date-time value
set clock leapseconds value
Level 3:
Same as Level 2
Remarks: If the Time of Day source has set the date and time, the user is not
allowed to overwrite the date, time.
Related: show clock
Restrictions: The format is yyyy-mm-dd;hh:mm:ss.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 113
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set Configuration
Use this command to backup the current configuration, restore the current
configuration from a backup copy, or set the current configuration to factory default
values.
Level 1:
Not Applicable
Level 2:
set configuration {default | factory}
set configuration backup {imc-to-ioc | ioc-to-imc |local|
backup | default | factory | restore}
set configuration restore {imc-from-ioc | ioc-from-imc}
Default preserves user logins and communication attributes, such as ip addresses.
Factory resets all attributes.
Backup IMC-to-IOC or IOC-to-IMC (Saves configuration to local non-volatile
storage immediately).
Restore IMC-from-IOC or IOC-from-IMC.
Level 3:
Same as Level 2
Remarks: Setting the configuration to Default will not overwrite all user login
information or system's IP address.
Related: See Set commands
114 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show EIA-232
This command displays the serial ports operating parameters: baud rate, parity,
word length, and stop bits.
Level 1:
show eia-232
Baud rate
Stop bit
Parity
Data length
Flow control
Level 2:
Same as Level 1
Level 3:
Same as Level 1
57600
1
0
8
none
Remarks: The system's serial interface is fixed at 57.6K, 0, 8, 1; there is no
handshaking. There is no associated Set command.
Related: show services
7
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 115
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Event
This command displays the current events.
Level 1:
show event
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks:
Related: set | show services
116 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Firewall
This command displays the firewall configuration.
Level 1:
Not Applicable
Level 2:
show firewall
Level 3:
Same as Level 2
Related: set firewall
Example:
tp5000> show firewall <enter>
ICMP Firewall
TELNET Firewall
SSH Firewall
SFTP Firewall
SNMP Firewall
FTP Firewall
allow
block
allow
allow
allow
block
Set Firewall
Use this command to configure the systems Ethernet port firewall.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
set
set
set
set
set
set
firewall
firewall
firewall
firewall
firewall
firewall
imc telnet {enable|disable}
imc ssh {enable|disable}
imc ftp {enable|disable}
imc sftp {enable|disable}
imc snmp {enable|disable}
[imc|iocx-y]icmp {enable|disable}
IOCx-y where x=1 | 2 and y=A | B
Remarks: The firewall can control Telnet, SSH, FTP, and SNMP on the IMC's or
IOC's PTP ports. Telnet is disabled by default.
Related: show firewall
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 117
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Generate
This command generates an event or alarm message.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
generate message
Related:
Example:
tp5000> generate message
message - Generate event/alarm messages
tp5000> generate message
118 TimeProvider 5000 Users Guide
<enter> - Execute command
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show GPS
This command displays the position (latitude, longitude, height), elevation mask
value (positioning filter), mode of operation (manual or automatic), and GPS
satellite tracking status. It also displays information for all satellite vehicles being
tracked: vehicle number, health, noise ratio, satellite elevation, satellite azimuth.
Level 1:
show gps
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set gps
Example: tp5000>show GPS <enter>
GPS Information
GPS Mode
GPS Mask
GPS Antenna Delay
- auto
- 10
- 0
GPS Latitude
GPS Longitude
GPS Height
- N37:22:42.900
- W121:55:34.571
- 15.4
---------------------------------------------------------|Index |No.
|SNR
|Health
|Azimuth |Elevation|
|------|---------|---------|---------|---------|---------|
|1
|3
|37
|healthy |313
|23
|
|......|.........|.........|.........|.........|.........|
|2
|6
|38
|healthy |309
|35
|
|......|.........|.........|.........|.........|.........|
|3
|15
|43
|healthy |57
|31
|
|......|.........|.........|.........|.........|.........|
|4
|16
|39
|healthy |259
|24
|
|......|.........|.........|.........|.........|.........|
|5
|18
|39
|healthy |300
|82
|
|......|.........|.........|.........|.........|.........|
|6
|21
|42
|healthy |36
|67
|
|......|.........|.........|.........|.........|.........|
|7
|22
|42
|healthy |240
|47
|
|......|.........|.........|.........|.........|.........|
|8
|24
|42
|healthy |85
|29
|
|......|.........|.........|.........|.........|.........|
|9
|26
|38
|healthy |42
|18
|
|......|.........|.........|.........|.........|.........|
|10
|29
|42
|healthy |150
|26
|
----------------------------------------------------------
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 119
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set GPS
Use this command to provision the GPS for mode of operation, position, and
positioning elevation mask. With this command, you can provision the GPS to use
either automatic or manual mode to determine the systems position. You can
provision the GPS position if the system is provisioned for Manual mode of
operation. You can also provision the elevation mask to provide a method of filtering
satellites to be used by the system.
Note: Latitude and Longitude are entered as pddd:mm:ss.sss, where
p is N or S for latitude and E or W for longitude, ddd is degrees, mm is
minutes, and ss.sss is seconds. For example: N59:20:3.458 or
W121:31:42.69. Height is in meters.
Level 1:
Not Applicable
Level 2:
set gps mode [auto|manual position lat long height
set gps mask value
set gps cable-delay value
Latitude is in the format N|Sdd:mm:ss.sss, for example:
N37:22:45.123
S48:33:67.456
Longitude is in the format E|Wddd:mm:ss.sss, for example:
W121:55:36.123
E157:33:47.456
Height is in meters with one digit after the decimal point, for
example:
17.5
Level 3:
Same as Level 2
Related: show gps
Restrictions: The system must have the GPS mode of operation provisioned as
manual before you can successfully provision the position manually.
120 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Hardware-status
This command displays the status of the specified hardware.
Level 1:
show hardware-status {imc | ioc1 | ioc2}
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related:
Examples:
tp5000> show hardware-status imc <enter>
-48V-A
-48V-B
+1.2V
+1.8V
+2.5V
+5.5V
VCXO
GPS Power
GPS Current
GPS Antenna
FPGA
:
:
:
:
:
:
:
:
:
:
:
ok
failed
2.423V
2.449V
0.386V
3.506V
0.360V
0.824V
109mA
ok
failed
tp5000> show hardware-status ioc1 <enter>
+1.8V
10M EFC
20M EFC
25M EFC
24.5M EFC
24.7M EFC
OSC Current
FPGA VCCint
FPGA VCCaux
FPGA Temp
FPGA Temp High
FPGA Temp Low
098-00028-000 Revision A December, 2008
:
:
:
:
:
:
:
:
:
:
:
:
1.808V
1.143V
0.957V
1.143V
1.001V
1.177V
168mA
1.008V
2.499V
76C
77C
64C
TimeProvider 5000 Users Guide 121
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
History
This command shows the command history for the current session.
Level 1:
history
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related:
Example:
tp5000> history
<enter> - Execute command
0 2008-01-01 05:04:41 show alarm-config
1 2008-01-01 05:05:13 history
2 2008-01-01 05:08:09 show ioc-state
3 2008-01-01 05:08:31 show ptp-client ioc1-1
4 2008-01-01 05:12:29 show ptp-status
5 2008-01-01 05:12:51 show ptp-status ioc1-1
6 2008-01-01 05:13:19 show ptp-config
7 2008-01-01 05:13:32 show ptp-config common ioc1-1
8 2008-01-01 05:14:17 show ptp-config unicast ioc1-1 index 1
9 2008-01-01 05:16:08 show log-size alarm
10 2008-01-01 05:16:15 show log-size event
11 2008-01-01 05:16:21 show log-size command
12 2008-01-01 05:16:26 show log-size security
13 2008-01-01 05:17:23 show redundancy port
14 2008-01-01 05:17:50 show status
15 2008-01-01 05:18:17 show option
16 2008-01-01 05:18:45 show remote-syslog
17 2008-01-01 05:19:40 show ref
18 2008-01-01 05:20:59 show output-pps
19 2008-01-01 05:21:12 show tod-source
20 2008-01-01 05:21:28 show led
21 2008-01-01 05:24:34 show user
22 2008-01-01 05:24:39 show history
23 2008-01-01 05:24:43 history
tp5000>
122 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Hostname
This command displays the host name for the TimeProvider 5000.
Level 1:
show hostname
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set hostname
Example:
tp5000> show hostname <enter> - Execute command
Host name
- TP5000
Set Hostname
This command sets the host name for the TimeProvider 5000.
Level 1:
Not Applicable
Level 2:
set hostname hostname_string
Level 3:
Same as Level 2
Remarks: Hostname can contain up to 20 characters.
Related: show hostname
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 123
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Image
This command displays the firmware image used by each module in the system and
the firmware version.
Level 1:
show image
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set image
Example:
tp5000> show image
<enter> - Execute command
IMC IMAGE DETAILS
Active image:
2
Backup image:
1
Next boot image: 2
1.0.4_200811040901
1.0.2_200810231325
IOC1 IMAGE DETAILS
Active image:
2
Backup image:
1
Next boot image: 2
1.0.4_200811040858
1.0.2_200810231322
IOC2 IMAGE DETAILS
Active image:
2
Backup image:
1
Next boot image: 2
1.0.4_200811040858
1.0.4_200811040858
Set Image
Use this command to provision the module firmware image from which to boot.
Level 1:
Not Applicable
Level 2:
set image [imc|ioc1|ioc2][1|2]
Level 3:
Same as Level 2
Related: show image
124 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Input
This command displays the input port's priority, framing type, zero suppression,
CRC, SSM Bit (if applicable), user assigned SSM value. It also displays the input
port's status (OK, ALM, DIS).
Level 1:
show input
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set input
Example:
tp5000> show input
-----------------------------------------------------------------------------|Port |State |Prio|Frame Type |CRC State|SSM State|SSM Bit|SSM Val|SSM Cur|
|------|-------|----|------------|---------|---------|-------|-------|-------|
|port1 |disable|1
|freq2048khz |disable |disable |8
|3
|15
|
|......|.......|....|............|.........|.........|.......|.......|.......|
|port2 |disable|2
|freq2048khz |disable |disable |8
|3
|15
|
------------------------------------------------------------------------------
Set Input
Use this command to provision the System's Input Port(s) for the following:
Priority
State
Framing Type
CRC state
SSM state
SSM Bit value for E1 signals
SSM PQL Value
PQL values are listed in the following table.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 125
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Quality Level
DS1 SSM
E1 SSM
Description
0x04
0x02
Stratum 1/PRS/PRC
0x08
0x00
STU, Stratum Unknown (presumed ST1)
0x0C
0x04
Stratum 2/Type II
0x0C
0x04
Type I
0x78
0x04
Transit Node/Type V
0x7C
0x08
Type III/Stratum 3E
0x10
0x0B
Type IV/Stratum 3
0x22
0x0F
G.813OPT3/SMC
0x30
0x0F
DUS, Do not Use for Sync
Level 1:
Not Applicable
Level 2:
set
set
set
set
set
set
Level 3:
Same as Level 2
input priority port# [1|2]
input state port# [enable|disable]
input frametype port# [ccs|cas|2048khz]
input crc port# [enable|disable]
input ssm port# [enable|disable]
input ssm-bit port# [4 thru 8] (used only for ccs or
cas framing type)
set input ssm-value port# [pql value]
where # is a choice between 1 | 2, and pql value is from 1 to 9
Related: show input
Example:
tp5000> set input ssm-value port1 <tab>
1
2
3
4
5
6
7
8
9
Stratum 1/PRS/PRC
STU, Stratum unknown
Stratum 2/Type II
Type I
Transit Node/Type V
Type III/Stratum 3E
Type IV/Stratum 3
G.813OPT3/SMC
DUS, Don't use for Sync
126 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Intra-System
Use this command to display which Class of network and IP addresses are used for
IMC-to-IOC and IOC-to-IOC communications.
Level 1:
Not Applicable
Level 2:
set intra-system [a|b|c]
A: IP address range 10.0.250.8 to 10.0.250.47
B: IP address range 172.16.250.8 to 172.16.250.47
C: IP address range 192.168.250.8 to 192.168.250.47
Level 3:
Same as Level 2
Remarks: These addresses can't be used for external Ethernet ports.
Related: show ip
Example:
tp5000> show intra-system <enter>
Intra-communication IP set
- setB
Set Intra-System
Use this command to provision which Class of network and IP addresses are used
for IMC-to-IOC and IOC-to-IOC communications.
Level 1:
Not Applicable
Level 2:
set intra-system [a|b|c]
A: IP address range 10.0.250.8 to 10.0.250.47
B: IP address range 172.16.250.8 to 172.16.250.47
C: IP address range 192.168.250.8 to 192.168.250.47
Level 3:
Same as Level 2
Remarks: These addresses can't be used for external Ethernet ports.
Related: show ip
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 127
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Inventory
This command displays the installed module inventory information as follows:
model number
user-assigned asset number
IMC and IOC module part numbers
IMC and IOC module CLEI numbers
IMC and IOC module serial numbers
IMC and IOC module hardware versions
IMC and IOC module FPGA versions
IMC and IOC module compatibility mask
IMC and IOC module firmware versions
The firmware may include operating system and application versions.
Level 1:
show inventory
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks: Only the asset number can be modified.
Related: set inventory
Example:
tp5000> show inventory <enter> - Execute command
General Inventory Info:
System Model
- TimeProvider 5000
Chassis Type
- front-access(090-50301-01)
I/O Module Type
- 4 port E1 I/O
module(090-50311-01)
Asset Number
- unknown
Module Inventory Info:
------------------------------------------------------------------------------|Mod |Part Num
|CLEI Num
|Serial |HW Ver |FPGA |SW Version|Compati.|
|----|----------------|-----------|--------|-------|------|----------|--------|
|imc |090-50331-01-2 |unknown
|R62310 |2
|0x14 |1.0.4
|0
|
|....|................|...........|........|.......|......|..........|........|
|ioc1|unknown
|unknown
|unknown |unknown|0x19 |1.0.4
|0
|
|....|................|...........|........|.......|......|..........|........|
|ioc2|090-50321-01
|unknown
|P37401 |B
|0x19 |1.0.4
|0
|
-------------------------------------------------------------------------------
128 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set Inventory
Use this command to provision the system's user-assigned asset value information.
Level 1:
Not Applicable
Level 2:
set inventory asset value
Enter user-assigned asset value from 1 to 20 characters.
Level 3:
Same as Level 2
Related: show inventory, show image, set image
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 129
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show IO
This command displays the system's port configuration for the two ports that can be
defined as either Input or Output.
Level 1:
show io
Level 2:
Same as Level 1
Level 3:
Same as Level 1
130 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show IOC-State
This command displays the state of both the active and standby IOC module. If either
IOC module cannot assume the active, standby, or disabled state, the state indicates
NOT AVAILABLE.
Level 1:
show ioc-state
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set ioc-state
Set IOC-State
Use this command to provision the standby module to become the active module, or
for either module to be disabled. IOC1 references the IOC module to the left of the
IMC and IOC2 references the IOC module to the right of the IMC.
Level 1:
Not Applicable
Level 2:
set ioc-state {ioc1 | ioc2} active
Level 3:
Same as Level 2
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 131
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show IP
This command displays the Host, Mask, and Gateway IP addresses for Ethernet
interfaces on the specified module. It also indicates if DHCP is enabled and if the
port is enabled.
Level 1:
show ip config [imc|ioc1|ioc2]
show ip status [imc|ioc1|ioc2]
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set ip
Remarks: The default IP settings are:
IMC:
IP MODE:
IP ADDRESS 192.168.0.100
GATEWAY: 0.0.0.0
IOC1:
IOC1-1
IOC1-2
IOC2:
IOC2-1
IOC2-2
NETMASK: 255.255.255.0
IP ADDRESS 192.168.1.11
GATEWAY: 0.0.0.0
IP ADDRESS 192.168.2.11
GATEWAY: 0.0.0.0
NETMASK: 255.255.255.0
IP ADDRESS 192.168.1.31
GATEWAY: 0.0.0.0
IP ADDRESS 192.168.2.31
GATEWAY: 0.0.0.0
NETMASK: 255.255.255.0
NETMASK: 255.255.255.0
NETMASK: 255.255.255.0
Examples:
tp5000> show ip config imc <enter> - Execute command
MGMT PORT PARAMETERS
IP mode
:
static
IP address:
192.168.0.100
IP mask
:
255.255.255.0
IP gateway:
0.0.0.0
tp5000> show ip status imc
<enter> - Execute command
MGMT
Link encap:Ethernet HWaddr 00:B0:AE:01:A5:6F
inet addr:192.168.0.100 Bcast:192.168.0.255 Mask:255.255.255.0
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:1450 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:91688 (89.5 KiB) TX bytes:0 (0.0 B)
Interrupt:21 Base address:0xe000
132 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
tp5000> show ip config ioc1 <enter> - Execute command
IP address:
IP mask
:
IP gateway:
ETH1 PORT PARAMETERS
192.168.1.11
255.255.255.0
0.0.0.0
IP address:
IP mask
:
IP gateway:
ETH2 PORT PARAMETERS
192.168.2.11
255.255.255.0
0.0.0.0
tp5000> show ip status ioc1
<enter> - Execute command
bond0
Link encap:Ethernet HWaddr 00:B0:AE:00:00:06
inet addr:192.168.1.11 Bcast:192.168.1.255 Mask:255.255.255.0
UP BROADCAST MASTER MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:0
RX bytes:0 (0.0 B) TX bytes:0 (0.0 B)
ETH1
Link encap:Ethernet HWaddr 00:B0:AE:00:00:06
UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 B) TX bytes:0 (0.0 B)
ETH2
Link encap:Ethernet HWaddr 00:B0:AE:00:00:06
UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 B) TX bytes:0 (0.0 B)
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 133
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set IP
Use this command to provision the Host, Mask, and Gateway IP addresses for both
Ethernet interfaces.
Level 1:
Not Applicable
Level 2:
set ip [imc|ioc[x-y] [enable|disable|restart]
set ip [imc|ioc[x-y] address <addr_value> netmask
<mask_value> gateway <gateway value>
iocx where: x=1 | 2, where x is the IOC module number
y=1 | 2, where y is the port number on the IOC
Level 3:
Same as Level 2
Remarks: The address format allows IPv4 multiple octet formats. Restart the
interface after configuring the system.
Note: PTP will be restarted after the IP interface is restarted.
Related: show ip, set ip-mode, set intra-system
134 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set IP-Mode
Use this command to set the DHCP mode for the IMC Ethernet interface. You can
set up the interface to use either DHCP or a static IP.
Level 1:
Not Applicable
Level 2:
set ip-mode imc {dhcp|static}
Level 3:
Same as Level 2
Remarks: Use set ip to restart the interface after configuring the system.
Related: show ip, set ip
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 135
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show LED
This command displays the LED status for each of the modules.
Level 1:
show led
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Remarks:
Related:
Example:
tp5000> show led
------------------------------------------|Index|Module ID|LED
|LED Status |
|-----|---------|------------|------------|
|1
|imc
|bta
|off
|
|.....|.........|............|............|
|2
|imc
|btb
|off
|
|.....|.........|............|............|
|3
|imc
|sys
|red
|
|.....|.........|............|............|
|4
|imc
|alm
|red
|
|.....|.........|............|............|
|5
|imc
|gps
|green
|
|.....|.........|............|............|
|6
|imc
|mgmt
|green
|
|.....|.........|............|............|
|7
|ioc1
|active
|green
|
|.....|.........|............|............|
|8
|ioc1
|alarm
|amber
|
|.....|.........|............|............|
|9
|ioc1
|eth1
|off
|
|.....|.........|............|............|
|10
|ioc1
|eth2
|off
|
|.....|.........|............|............|
|11
|ioc1
|holdover
|off
|
|.....|.........|............|............|
|12
|ioc2
|active
|off
|
|.....|.........|............|............|
|13
|ioc2
|alarm
|amber
|
|.....|.........|............|............|
|14
|ioc2
|eth1
|off
|
|.....|.........|............|............|
|15
|ioc2
|eth2
|off
|
|.....|.........|............|............|
|16
|ioc2
|holdover
|off
|
-------------------------------------------
136 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Log
This command displays the specified log file from the local storage. The Index
parameter selects one of the rotated log files. The Head parameter, along with the
count value, displays the specified number of events from the beginning of the file.
The Tail parameter, along with the count value (#), displays the specified number of
events from the end of the file. If the Index is not specified or set to zero, the current
log file is displayed. If neither Head nor Tail parameter is issued, the 20 most recent
entries are displayed. The command displays the specified logs user provisioned
line buffer size and total number of lines buffered. The log files are:
Alarm Log
Event Log
Command Log
Security Log
Level 1:
show log {alarm|event|command|
security} [index {head|tail} count]
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: show log-size, set log-size
Examples:
tp5000> show log <tab>
alarm
event
command
security
alarm log
event log
command log
security log
tp5000> show log alarm
<enter> - Execute command
Jan 01 00:02:49 TP5000 alarmd: 000,CRITI, IMC: Communication to IOC2 failure
cleared
Jan 01 00:04:49 TP5000 alarmd: 024,MINOR, IOC1: Transitioned out of warmup
mode
Jan 01 00:04:49 TP5000 alarmd: 034,MINOR, IOC1: GPS disqualification
cleared
Jan 01 00:04:49 TP5000 alarmd: 063,MINOR, IOC1: Input GPS not tracking
cleared
Jan 01 00:04:50 TP5000 alarmd: 007,MINOR, IOC1: ETH2 port link down cleared
Jan 01 00:04:50 TP5000 alarmd: 007,MINOR, IOC1: ETH1 port link down cleared
Jan 01 00:04:55 TP5000 alarmd: 021,MINOR, IMC: IOC detected but none of them
active
Jan 01 00:05:03 TP5000 alarmd: 058,CRITI, IMC: IMC-IOC FPGA link failed
Jan 01 00:05:29 TP5000 alarmd: 000,CRITI, IMC: Communication to IOC1 failed
Jan 01 00:05:50 TP5000 alarmd: 021,MINOR, IMC: Active IOC detected
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 137
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Jan 01 00:05:50 TP5000 alarmd: 058,CRITI, IMC: IMC-IOC FPGA link failure
cleared
Jan 01 00:05:53 TP5000 alarmd: 016,CRITI, IMC: FPGA access failure
Jan 01 00:08:00 TP5000 alarmd: 064,MINOR, IOC1: Input GPS RGP data loss
Jan 01 00:08:00 TP5000 alarmd: 034,MINOR, IOC1: GPS disqualified as system
reference
Jan 01 00:08:00 TP5000 alarmd: 024,MINOR, IOC1: Entered warmup mode
Jan 01 00:08:00 TP5000 alarmd: 064,MINOR, IOC1: Input GPS RGP data loss
cleared
Jan 01 00:08:00 TP5000 alarmd: 063,MINOR, IOC1: Input GPS not tracking
Jan 01 00:08:24 TP5000 alarmd: 000,CRITI, IMC: Communication to IOC1 failure
cleared
Jan 01 00:08:52 TP5000 alarmd: 007,MINOR, IOC1: ETH1 port link down
Jan 01 00:08:52 TP5000 alarmd: 007,MINOR, IOC1: ETH2 port link down
tp5000> show log event <enter> - Execute command
Nov 03 19:23:33 TP5000 alarmd: 032,EVENT, IOC1: GPS inactive
Nov 03 19:23:34 TP5000 alarmd: 027,EVENT, IOC1: Transitioned out of
normal-track mode
Nov 03 19:23:34 TP5000 alarmd: 028,EVENT, IOC1: Entered bridging mode
Nov 03 19:38:34 TP5000 alarmd: 028,EVENT, IOC1: Transitioned out of bridging
mode
Nov 05 20:41:02 TP5000 alarmd: 022,EVENT, IMC: Module reboot
Oct 14 12:04:05 TP5000 alarmd: 032,EVENT, IOC1: GPS active
Oct 14 12:04:27 TP5000 alarmd: 032,EVENT, IOC1: GPS inactive
Oct 14 12:04:36 TP5000 alarmd: 047,EVENT, IMC: IOC1 present
Oct 14 12:04:36 TP5000 alarmd: 047,EVENT, IMC: IOC2 present
Oct 14 12:05:22 TP5000 alarmd: 022,EVENT, IOC1: Module reboot
Oct 14 12:05:28 TP5000 alarmd: 022,EVENT, IMC: Module reboot
Jan 01 00:00:21 TP5000 alarmd: 005,EVENT, IOC1: IMC time has been updated
Jan 01 00:01:00 TP5000 alarmd: 047,EVENT, IMC: IOC1 present
Jan 01 00:01:00 TP5000 alarmd: 047,EVENT, IMC: IOC2 present
Jan 01 00:02:44 TP5000 alarmd: 048,EVENT, IMC: IOC2 not present
Jan 01 00:04:50 TP5000 alarmd: 022,EVENT, IOC1: Module reboot
Jan 01 00:05:47 TP5000 alarmd: 047,EVENT, IMC: IOC2 present
Jan 01 00:05:48 TP5000 alarmd: 048,EVENT, IMC: IOC2 not present
Jan 01 00:08:06 TP5000 alarmd: 005,EVENT, IOC1: IMC time has been updated
Jan 01 04:00:15 TP5000_ACT alarmd: 005,EVENT, IMC: IMC time has been updated
tp5000> show log command
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
Jan
01
01
01
01
01
01
01
01
01
01
02
02
02
02
02
03:30:50
03:30:54
03:32:03
03:33:08
03:33:29
03:40:55
03:41:48
03:45:25
03:45:29
03:46:38
01:29:42
01:30:29
01:30:36
01:35:30
01:36:00
138 TimeProvider 5000 Users Guide
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
<enter> - Execute command
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
[user:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
admin]:
show
show
show
show
show
show
show
show
show
show
show
show
show
show
show
ptp-status
ptp-status
ioc-state
option
alarm
auto-sync
ref
ptp-status
ptp-status
ioc-state
hostname
user
led
status
alarm
ioc1-2
ioc1-1
ioc1-1
ioc1-2
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Jan
Jan
Jan
Jan
Jan
02
02
02
02
02
01:38:31
01:39:57
01:40:11
01:40:15
01:40:25
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
TP5000_ACT
KCLI:
KCLI:
KCLI:
KCLI:
KCLI:
tp5000> show log security
[user:
[user:
[user:
[user:
[user:
admin]:
admin]:
admin]:
admin]:
admin]:
show
show
show
show
show
image
log event
log alarm
log event
log command
<enter> - Execute command
Nov 03 18:09:44 TP5000 login[2048]: (pam_unix) check pass; user
unknown
Nov 03 18:09:46 TP5000 login[2048]: PAM: failed login: 2 from: symm
error: Authentication failure
Nov 03 18:18:33 TP5000 login[10783]: (pam_unix) check pass; user
unknown
Nov 03 18:18:33 TP5000 login[10783]: (pam_unix) authentication
failure; logname= uid=0 euid=0 tty=ttyS0 ruser= rhost=
Nov 03 18:18:35 TP5000 login[10783]: PAM: failed login: 1 from:
symm error: Authentication failure
Nov 03 18:18:45 TP5000 login[10783]: (pam_unix) check pass; user
unknown
Nov 03 18:18:47 TP5000 login[10783]: PAM: failed login: 2 from:
symm error: Authentication failure
Nov 03 18:20:20 TP5000 login[14832]: (pam_unix) check pass; user
unknown
Nov 03 18:20:20 TP5000 login[14832]: (pam_unix) authentication
failure; logname= uid=0 euid=0 tty=ttyS0 ruser= rhost=
Nov 03 18:20:22 TP5000 login[14832]: PAM: failed login: 1 from:
symm error: Authentication failure
Nov 03 18:20:28 TP5000 login[14832]: (pam_unix) check pass; user
unknown
Nov 03 18:20:30 TP5000 login[14832]: PAM: failed login: 2 from:
symm error: Authentication failure
Nov 03 18:20:36 TP5000 login[14832]: (pam_unix) check pass; user
unknown
Nov 03 18:20:39 TP5000 login[14832]: PAM: failed login: 3 from:
symm error: Authentication failure
Nov 03 18:23:46 TP5000 login[15647]: admin login
Nov 05 20:36:18 TP5000 login[22890]: admin login
Oct 14 12:04:35 TP5000 login[1135]: admin login
Jan 01 00:03:11 TP5000 login[1135]: admin login
Jan 01 03:22:14 TP5000_ACT login[28819]: admin login
Jan 02 01:28:48 TP5000_ACT login[32184]: admin login
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 139
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Log-size
Use this command to display the specified log buffer, the maximum number of
kilobytes stored in the file before it is rotated.
Level 1:
show log-size {alarm|event|command|security}
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: show log, set log-size
Examples:
tp5000> show log-size
alarm
event
command
security
alarm
event
command
security
tp5000> show log-size alarm
Log size of alarm log is
100 kilobytes
tp5000> show log-size event
Log size of event log is
100 kilobytes
tp5000> show log-size command
Log size of command log is
100 kilobytes
tp5000> show log-size security
Log size of security log is
100 kilobytes
Set Log-size
Use this command to provision the specified log file buffer size, the maximum
number of kilobytes to be stored in the file before it is rotated.
140 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Level 1:
Not Applicable
Level 2: set log-size {alarm|event|command|security}size
Level 3:
Same as Level 2
Remarks: Provisioning a log file size to zero disables the logging of that type of
data.
Related: show log-size
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 141
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Logout
This command terminates the current user connection.
Level 1:
logout
Level 2:
Same as Level 1
Level 3:
Same as Level 1
142 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Option
This command displays the option mode and key information.
Level 1:
show option
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related:
Example:
tp5000> show option <enter> - Execute command
OPTION SERVICE
-------------SNMP
OPTION KEY
---------not available
KEY VALIDITY
-----------invalid
Set Option
This command sets the option mode and key information.
Level 1:
Not Applicable
Level 2:
set option
Level 3:
Same as Level 2
Related:
Example:
tp5000> set option
snmp - snmp
tp5000> set option snmp
<value String 6 - 6> - Enter key string
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 143
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Output-10M
This command displays the System's 10 MHz Output Port state.
Level 1:
show output-10m
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set output-10m
Example:
tp5000> show output-10m <enter>
10MHz output parameters
Port status
Output generation
- enable
- normal
Set Output-10M
Use this command to provision the System's 10 MHz Output Port state and enable
the port to begin generating outputs when the specified operating mode is achieved.
Level 1:
Not Applicable
Level 2:
set output-10m state [enable|disable]
set output-10m generation {warm-up|free-run|
fast-lock|normal}
Level 3:
Same as Level 2
Related: show output-10m
144 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Output-PPS
This command displays the System's 1PPS Output Port state and output generation
level.
Level 1:
show output-pps
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set output-pps
Example:
tp5000> show output-pps <enter>
1PPS output parameters
Port status
Output generation
- enable
- normal
Set Output-PPS
Use this command to provision the System's 1PPS Output Port state and to enable
the port to begin generating outputs when the specified operating mode is achieved.
Level 1:
Not Applicable
Level 2:
set output-pps state [enable|disable]
set output-pps generation {warm-up|free-run|
fast-lock|normal}
Level 3:
Same as Level 2
Related: show output-pps
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 145
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Ping
Use this command to ping the host specified by the address (xxx.xxx.xxx.xxx) and
display ping statistics.
Level 1:
ping [imc|iocx-y [vlanid vlanid] address
Where x is the IOC number and y is the port number on the IOC
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Examples:
tp5000>ping <tab>
imc
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IMC MGMT for PING operation
IOC1 eth1 for PING operation
IOC1 eth2 for PING operation
IOC2 eth1 for PING operation
IOC2 eth2 for PING operation
tp5000> ping imc 192.168.100 <enter>
Ping imc success
146 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set PTP
Use this command to provision the PTP ports common provisioned attributes,
multicast specific attributes, and unicast specific attributes.
Common Provisioned Attributes:
Addressing Mode, Clock ID, Port Redundancy, Module Redundancy, Priority 1,
Priority 2, Domain, Diffserv State, Diffserv Code Point.
Unicast Specific Attributes:
Unicast Negotiation Flag, Dynamic Lease Interval, Unicast IP ranges (up to ten
groups), VLAN State, VLAN Priority, VLAN ID, Sync Message Interval, Announce
Message Interval, Delay Interval
Level 1:
Not Applicable
Level 2:
Common
set
set
set
set
set
set
set
set
set
set
set
set
set
ptp
ptp
ptp
ptp
ptp
ptp
ptp
ptp
ptp
ptp
ptp
ptp
ptp
timescale {auto | arb | ptp}
state ioc[#][-1|-2] {enable | disable}
max-client ioc[#][-1|-2] value
announce-limit ioc[#][-1|-2] value
sync-limit ioc[#][-1|-2] value
delay-limit ioc[#][-1|-2] value
profile ioc[#][-1|-2] value
clockid ioc[#][-1|-2] value
priority-1 ioc[#][-1|-2] value
priority-2 ioc[#][-1|-2] value
domain ioc[#][-1|-2] value
dscp ioc[#][-1|-2] value
dscp-state ioc[#][-1|-2] {enable|disable]
Unicast
set ptp unicast negotiate ioc[#][-1|-2] [enable|disable]
set ptp unicast lease-duration ioc[#][-1|-2] [10 t0 1000]
set ptp unicast state ioc[#][-1|-2] [1 - 10]
[enable|disable]
set ptp unicast address ioc[#][-1|-2] {add|remove} [1 - 10]
address1
set ptp unicast clockid ioc[#][-1|-2] [1 - 10] value
set ptp unicast vlanid ioc[#][-1|-2] [1 - 10] value
set ptp unicast sync-int ioc[#][-1|-2] [1 - 10] rate_value
set ptp unicast announce-int ioc[#][-1|-2] [1 - 10]
rate_value
set ptp unicast delay-int ioc[#][-1|-2] [1 - 10] rate_value
Level 3:
Same as Level 2
Related: show ip, set ip, show ptp
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 147
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show PTP-client
Use this command to display the PTP client attributes:
Level 1:
Not Applicable
Level 2:
show ptp-status
Level 3:
Same as Level 2
Related: show ptp-config, show ptp-status
Example:
tp5000> show ptp-client
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> show ptp-client ioc1-1 <enter> - Execute command
No client
148 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show PTP-config
Use these commands to display the PTP ports common provisioned attributes and
unicast specific attributes.
Common Provisioned Attributes:
PTP Profile, Clock ID, Port ID, Port Redundancy, and Module Redundancy.
Unicast Specific Attributes:
Unicast Negotiation Flag, Dynamic Lease Interval, Unicast IP ranges (up to ten
groups), Two-Step process state, Priority 1, Priority 2, Domain, VLAN Priority, VLAN
ID, Diffserv Code Point, TTL value, Sync Message Interval, Announce Message
Interval, Delay Interval, PDelay Interval.
Level 1:
Not Applicable
Level 2:
show ptp-config common IOC-x-y
show ptp-config unicast IOC-x-y index <index>
Where:
x = 1 or 2 (for IOC1 or IOC2)
y = 1 or 2 (for ETH1 or ETH2)
Level 3:
Same as Level 2
Related: show ip, set ip, set ptp
Examples:
tp5000> show ptp-config
common - common parameters
unicast - unicast parameters
Unicast Example:
tp5000> show ptp-config common
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> show ptp-config common ioc1-1
098-00028-000 Revision A December, 2008
<enter>
TimeProvider 5000 Users Guide 149
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
PTP
Timescale
State
Max Number Clients
Profile
ClockId
Priority 1
Priority 2
Domain
DSCP
DSCP State
Sync Limit
Announce Limit
Delay Limit
Unicast Negotiation
Unicast Lease Duration
AUTO
enabled
500
unicast
FF:FF:FF:FF:FF:FF:FF:FF
128
128
0
4
disabled
-7
-3
-7
enabled
300
Unicast Example:
tp5000> show ptp-config unicast
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> show ptp-config unicast ioc1-1
index - client id
tp5000> show ptp-config unicast ioc1-1 index
<clientnum Integer 1 - 10> - Enter client id
tp5000> show ptp-config unicast ioc1-1 index 1 <enter> Execute command
PTP
PTP
PTP
PTP
PTP
PTP
PTP
Unicast
Unicast
Unicast
Unicast
Unicast
Unicast
Unicast
150 TimeProvider 5000 Users Guide
State
Addr
VlanId
ClockId
Sync Intv
Announce Intv
Delay Intv
disabled
0.0.0.0
0
FF:FF:FF:FF:FF:FF:FF:FF
-3
1
-3
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show PTP-status
Use this command to display the PTP ports common provisioned attributes:
PTP Profile
Clock ID
Current Port ID
Current Clock Class
Number of unique clients seen in last 60 seconds
Number of Transactions per Second.
Level 1:
Not Applicable
Level 2:
show ptp-status
Level 3:
Same as Level 2
Related: show ip, set ip, set ptp
Example:
tp5000> show ptp-status <tab>
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> show ptp-status ioc1-1 <enter> - Execute command
Grandmaster status information on ioc1 eth1 port:
Port Enabled
Clock Id
Profile
Clock Class
Clock Accuracy
Timescale
Num clients
Client load
Packet load
098-00028-000 Revision A December, 2008
:
:
:
:
:
:
:
:
:
yes
00:B0:AE:FF:FE:00:00:06
unicast
PTP_unknown
PTP_unknown
ARB
0
0%
0%
TimeProvider 5000 Users Guide 151
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Reboot
This command restarts one or more of the modules. Using this command can cause
a loss of outputs.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
reboot {system|imc|ioc1|ioc2}
Remarks: Selecting the system restarts all system modules. Selecting system, or
the only IOC, disrupts the system outputs.
Example 1:
tp5000> reboot <tab>
system
imc
ioc1
ioc2
Reset System
Reboot IMC Card
Reboot IOC1 Card
Reboot IOC2 Card
tp5000> reboot imc <enter> - Execute command
NO WARNING
The system is going down NOW!
Sending SIGTERM to all processes
Sending SIGKILL to all processes
Requesting system reboot
Restarting system.
U-Boot 1.1.6 (Oct 23 2008 - 13:17:59) MPC83XX
Symmetricom Time Provider 5000 (TP5000) IMC
Clock configuration:
Coherent System Bus:
Core:
Local Bus Controller:
Local Bus:
DDR:
SEC:
I2C1:
I2C2:
TSEC1:
TSEC2:
USB MPH:
USB DR:
166
333
166
41
333
55
166
166
166
166
0
55
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
CPU: MPC8313E, Rev: 10 at 333.333 MHz
INFO: Initializing IOMEM for regset 0
152 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
DRAM:
256 MB
NAND:
256 MiB
Using default environment
........................................
Symmetricom
tp5000_imc
login:
Example 2:
Reboot IOC1. No message until complete.
tp5000> reboot ioc1
NO MESSAGE.
NO INDICATION.
LED ALARM GREEN BLINKING
tp5000>
Example 3:
Defective IOC or no IOC
tp5000> reboot ioc2
<enter> - Execute command
Error
IOC is not present.
tp5000>
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 153
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Redundancy
This command displays the IOC redundancy configuration: Port Bonding and IOC
Module.
Level 1:
show redundancy port
show redundancy card
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set redundancy
Example:
tp5000> show redundancy
port - port
tp5000> show redundancy port <enter> - Execute command
------------------------------------------|Module ID|Redundancy
|Active Port
|
|---------|---------------|---------------|
|ioc1
|enable
|none
|
|.........|...............|...............|
|ioc2
|enable
|none
|
-------------------------------------------
Set Redundancy
Use this command to provision the IOC redundancy configuration: Port Bonding
and IOC Module.
Level 1:
Not Applicable
Level 2:
set redundancy port iocx [enable|disable]
set redundancy active-port iocx-y
iocx where: x=1 | 2 y=a | b
Level 3:
Same as Level 2
Related: show IP show redundancy
154 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show REF
Use this command to display the system's selected reference, reference mode, and
input reference mode.
Level 1:
show ref
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set ref, set input
Example:
tp5000> show ref
Reference Criteria
Reference Override
- priority
- port1
Set REF
Use this command to provision the system's input port(s) state and configuration. It
allows the user to select the system reference and override the currently selected
reference. This reference remains selected until failure, or until the user selects an
alternate reference.
When switching to backup frequency reference, the system selects the new
reference based on REF CRITERIA
When the TOD source is SYS, the default frequency reference is INP. In this case,
the selection of INP1 or INP2 is also based on INP REF MODE.
When Mode is set to MANUAL, the system requires Manual intervention to select
the backup reference.
When Mode is set to PRIORITY, the system selects the reference based on the
TOD Source and priority setting.
When Mode is set to SSM, the system selects the reference as frequency reference
based on the TOD Source and SSM (received or provisioned).
Level 1:
Not applicable
Level 2:
set ref override {port | utix}
set ref criteria {manual|priority|ssm}
Level 3:
Same as Level 2
Related: show ref, show input
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 155
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Remote-Syslog
This command displays the remote syslog server that log messages are sent to
from the TimeProvider 5000.
Level 1:
show remote-syslog
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set remote-syslog
Example:
tp5000> show remote-syslog
<enter> - Execute command
State
Remote Address
- disable
- 0.0.0.0
Set Remote-Syslog
This command is used to configure a remote syslog server to receive log messages
from the TimeProvider 5000.
Level 1:
Not Applicable
Level 2:
set remote-syslog {enable|disable} [hostaddr]
Level 3:
Same as Level 2
Related: show remote-syslog
156 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show SNMP
Use these commands to display the SNMP Manage assigned to the agent, all
assigned users (username only), and the SNMP trap version and SNMP trap user.
Level 1:
show snmp manager
Level 2:
Same as Level 1
Level 3:
Same as Level 1 and the following:
show snmp user
show trapuser
This command displays all assigned users (user names only).
show snmp trap
This command displays whether traps are sent as SNMPv2 or
SNMPv3 and also the SNMPv3 trap user.
show v2-community
This command displays the v2 community strings.
Related: set snmp
Examples:
tp5000> show snmp
manager
user
trapuser
v2-community
trapversion
state-v2
Show
Show
Show
Show
Show
Show
SNMP Manager assignment
SNMPv3 User Configuration
SNMP TRAP user information
SNMP v2-community information
SNMP TRAP version information
SNMP V2 state
tp5000> show snmp manager
No SNMP manager configured
tp5000> show snmp user
No SNMP user configured
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 157
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
tp5000> show snmp trapuser
No SNMP trap user configured.
tp5000> show snmp v2-community
SNMP community data is not available yet.
tp5000> show snmp trapversion
Trap version
- v2c
tp5000> show snmp state-v2
SNMP v2 state
158 TimeProvider 5000 Users Guide
- enable
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set SNMP
Use this command to provision the SNMP state, user assignment (up to 10 users),
and manager.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
set snmp add user username securLvl
{NoAuth, Auth, Private}
If security level is auth, prompt for:
AuthKey value
authType {MD5|SHA}
If security level is priv, prompt for:
authType {MD5|SHA}
AuthKey value
privType {DES|AES}
PrivKey value
set snmp
set snmp
set snmp
{NoAuth,
delete user username
trapversion {2|3}
add trapuser username securlvl
Auth, Private}
Prompts are the same as for set snmp add user.
set
set
set
set
set
set
snmp
snmp
snmp
snmp
snmp
snmp
delete trapuser username
add manager address [engineid value]
delete manager address
add v2-community name {read | read-write}
delete v2-community name
state-v2 {enable | disable}
Related: show snmp
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 159
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show Status
Use this command to display the following system status information:
Assigned System Name And Asset Tag
Uptime For The Imc
System Date And Time
Number Of Standing System Alarms
Active Ioc Module
Standby Ioc Module Is Available To Become The Active Ioc Module
Currently Selected TOD Source
Reference Input
Summary For Each UTI Client Port
Summary For Each UTI Server Port
Servo Control Status For The Active IOC Module
PTP Port(s) Summary:
PTP Port Configuration/State
Level 1:
show status
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: show alarms
Example:
tp5000> show status
System name
IMC uptime
IMC time
Active alarms
Ioc1 state
Ioc2 state
Tod source
Current reference input
Clock status
160 TimeProvider 5000 Users Guide
<enter> - Execute command
:
:
:
:
:
:
:
:
:
TP5000
5 hrs 20 mins
2008-01-01 05:26:22 (invalid)
8
active
standby
GPS
GPS
warmup
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Sync
This command synchronizes the Time Of Day Source.
Level 1:
Not Applicable
Level 2:
sync tod-source
Example:
tp5000> sync tod-source now <enter> - Execute command
tp5000>
Level 3:
Same as Level 2
Related: set tod-source
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 161
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set-Timeout
This command sets the inactivity timeout to the defined time interval, in seconds.
Level 1:
set-timeout
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related:
Example:
tp5000> set timeout <enter> - Execute command
Timeout (0 - 86400 sec): 1800
1800 sec timeout set successfully
tp5000>
162 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show TOD-Source
This command displays the Time Of Day Source and the last date and time of ToD
sync.
Level 1:
show tod-source
Example:
tp5000> show tod-source
ToD Source
Level 2:
Same as Level 1
Level 3:
Same as Level 1
<enter> - Execute command
- gps
Related: set tod-source, show gps
Set TOD-Source
Use this command to provision the TOD Source to be provided by GPS or the
System. You can also provision the TOD-Source to "sync".
Level 1:
Not Applicable
Level 2:
set tod-source {gps|sys}
sync tod-source
Level 3:
Same as Level 2 (default)
Related: show tod-source, set clock
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 163
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Upgrade
Use this command to upgrade the specified modules firmware with the specified
filename. If the IP address, username, and password is provided, the system will
FTP the filename from the specified server (IP or name) and then upgrade the
specified module.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
upgrade {imc|ioc|ioc1|ioc2} filename [protocol:]
ftp_server username passwd
Protocol can be either FTP or SFTP.
Related: ftp
Examples:
tp5000> show image
IMC IMAGE DETAILS
Active image:
1
Backup image:
2
Next boot image: 1
1.0.2_200810231325
1.0.2_200810231325
IOC1 IMAGE DETAILS
Active image:
1
Backup image:
2
Next boot image: 1
1.0.2_200810231322
1.0.2_200810231322
IOC2 IMAGE DETAILS
Active image:
1
Backup image:
2
Next boot image: 1
1.0.4_200811040858
1.0.4_200811040858
tp5000> upgrade imc /tp5000/current_tp5000_imc_upd
192.168.5.56 tp5000
Password:
Upgrade of imc is in progress
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade of imc is successfully completed
164 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
To verify the upgrade:
tp5000> show image
<enter> - Execute command
IMC IMAGE DETAILS
Active image:
2
Backup image:
1
Next boot image: 2
1.0.4_200811040901
1.0.2_200810231325
IOC1 IMAGE DETAILS
Active image:
2
Backup image:
1
Next boot image: 2
1.0.4_200811040858
1.0.2_200810231322
IOC2 IMAGE DETAILS
Active image:
2
Backup image:
1
Next boot image: 2
1.0.4_200811040858
1.0.4_200811040858
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 165
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show User
This command displays the list of users assigned access privileges to the system.
Level 1:
show user
Level 2:
Same as Level 1
Level 3:
show user
Display all assigned users, username and access level only are
displayed.
Related: set user, set snmp
Set User
Use this command to provision the local user password and access level, or to
delete the specified user or set the entire user table to default.
Level 1:
Not Applicable
Level 2:
Not Applicable
Level 3:
set user add <username> access-level
[user | config | admin]
Prompt for password
Prompt for password confirmation
set user delete username
Related: show user
166 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Show VLAN
Use this command to
Level 1:
Not Applicable
Level 2:
show vlan-config IOC-x-y
show vlan-mode IOC-x-y
Where:
x = 1 or 2 (for IOC1 or IOC2)
y = 1 or 2 (for ETH1 or ETH2)
Level 3:
Same as Level 2
Example:
tp5000> show vlan-mode
<enter> - Execute command
Results:
-------------------------------------|Index |Module ID|Port ID |State
|
|------|---------|---------|---------|
|1
|ioc1
|eth1
|disable |
|......|.........|.........|.........|
|2
|ioc1
|eth2
|disable |
|......|.........|.........|.........|
|3
|ioc2
|eth1
|disable |
|......|.........|.........|.........|
|4
|ioc2
|eth2
|disable |
--------------------------------------
tp5000> show vlan-config
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> show vlan-config ioc1-1
<enter> - Execute command
No vlans configured on ioc1 eth1 port.
tp5000> show vlan-config ioc2-1
<enter> - Execute command
No vlans configured on ioc2 eth1 port.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 167
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
Set VLAN
Use this command to
Level 1:
set vlan-mode iocx-y {enable | disable}
set vlan-config add ioc-x-y index {1..16} vlan_id <id>
priority <priority> address <address> netmask <mask>
gateway <gateway>
set vlan-config modify ioc-x-y index {1..16} address
<address> netmask <mask> gateway <gateway>
set vlan-config delete ioc-x-y index {1..16} vlan_id
set vlan-config state ioc-x-y index {1..16}
{enable | disable}
Where:
x = 1 or 2 (for IOC1 or IOC2)
y = 1 or 2 (for port ETH1 or ETH2)
index = 1 thru 16 (for VLAN table index)
vlan_id = 2 thru 4095 (0 is invalid and used as default, 1 is reserved)
priority = 0 thru 7
address, netmask and gateway are configured similarly to IP
configuration
vlan-mode is used to enable or disable VLAN on the specified physical Ethernet
port.
vlan state is used to enable or disable the VLAN associated with specified index.
Use set ip <port> restart after configuring VLAN to apply changes.
Note: Each VLAN must be configured on a separate subnet.
Level 2:
Same as Level 1
Level 3:
Same as Level 1
Related: set ip
Example:
tp5000> set vlan-config
add
modify
delete
state
168 TimeProvider 5000 Users Guide
Add a vlan id, address, mask and gateway
modify a vlan address, mask and gateway
VLAN delete
Enable/disable vlan id
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
TimeProvider 5000 CLI Command Set
tp5000> set vlan-config add
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> set vlan-config add ioc1-1 index 1 vlan-id 25
priority 0 address 192.168.1.5 netmask 255.255.255.0 gateway
192.168.1.1
tp5000> set vlan-config modify
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> set vlan-config modify ioc1-1 index 1 address
192.168.10.5 netmask 255.255.255.0 gateway 192.168.10.1
tp5000> set vlan-config delete
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> set vlan-config delete ioc1-1 index 4 <enter>
tp5000> set vlan-config state
ioc1-1
ioc1-2
ioc2-1
ioc2-2
IOC1-1
IOC1-2
IOC2-1
IOC2-2
(eth1)
(eth2)
(eth1)
(eth2)
port
port
port
port
tp5000> set vlan-config state ioc1-1 index 5
enable - Enable
disable - Disable
tp5000> set vlan-config state ioc1-1 index 5 enable <enter>
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 169
Appendix B Command Descriptions and Communications Interface
Simple Network Management Protocol
Simple Network Management Protocol
This section describes the two versions of SNMP supported by the TimeProvider
5000: SNMPv2c and SNMPv3.
Note: The SNMP feature can either be ordered in a new system, or
added to a previously ordered system as a field upgrade (see Table
2-1 for part number). Contact your Symmetricom representative for
more information.
SNMP Features
The Simple Network Management Protocol (SNMP) is an application layer protocol
that allows you to manage network devices. SNMP is based on a client-server
query-response mode that requires an Ethernet connection. A manager application
(software installed on a computer) is the client generating the queries, and an agent
(software on the TimeProvider 5000) is the server generating responses. The
TimeProvider 5000 SNMP supports most existing functions.
If SNMP is present, port 161 becomes the port of standard SNMP interactive
communications and port 162 becomes the trap port.
SNMP allows you to perform the following functions:
Alarm management
GPS input configuration
TOD source configuration
SNMPv3 Security Features
SNMPv3 provides additional security features not available in SNMPv2c. In addition
to the functions of SNMPv2c, SNMPv3 allows user levels that are based on
authentication and privacy settings. The authentication protocol HMAC-SHA-1-96 is
20 characters long and the privacy protocol CBC-DES is a 16-character key. All
keys are uppercase.
The administrator can add up to 10 users to the SNMP user table.
Management Information Base
The Management Information Base (MIB) is a virtual database of managed objects,
their object identifiers, and variables. Typical MIB object identifiers include the
TimeProvider 5000, its modules, module features, input ports, output ports, etc. and
variables that include settings and measurements.
170 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix B Command Descriptions and Communications Interface
Simple Network Management Protocol
The MIB is controlled by the TimeProvider 5000s SNMP agent. The SNMP agent is
a server program that sends TimeProvider 5000 status (stored in the MIB database)
to the network manager when the manager transmits GET or GETNEXT messages.
The manager can also transmit SET messages that instruct the agent to set MIB
variables to new values. The TRAP message is used by the server to send the
manager indications of MIB occurrences, such as a fault condition.
SNMP Users and Manager Addresses
SNMP CLI commands allows you to:
Enable and disable SNMP
Set SNMP manager IP address for traps
Add up to 10 SNMP user names in the SNMP user table
Display SNMP user names (read community string) and their associated access
levels
Delete SNMP user names
Enabling SNMP
This command allows you to enable or disable the SNMP.
Example:
Use the following command to enable SNMP:
Type set service snmp enable and press ENTER.
Adding a Manager IP Address
The Set SNMP Manager command allows you to specify an SNMP manager IP
address (see Set SNMP, on page 159).
Example:
Use the following command to add the SNMP manager IP address
192.100.100.100 and engineID 0x12345678901234567890:
Type set snmp manager address 192.100.100.100 engineid
0x12345678901234567890 then press Enter.
Adding and Removing SNMP Users
The Set SNMP User command allows you to add or remove users and specify
access privileges using algorithm HMAC-SH-1-96 or MD5 with the 20 character
authentication key and a CBC-DES 16 or AES character privacy key (see Set
SNMP, on page 159).
Example
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 171
Appendix B Command Descriptions and Communications Interface
Secure Shell Protocol
Use the following command to add user ABC with the 20 character MD5
authentication key 123456789ABCDEFGHIJK and 16 DES character privacy key
123456789ABCDEFG.
Type set snmp user add abc securlvl priv and press Enter.
Enter MD5 at the authentication protocol prompt.
Enter 123456789ABCDEFGHIJK at the authentication key prompt
Enter DES at the privacy protocol prompt
Enter 123456789ABCDEFG at the privacy key prompt
Displaying SNMP Users
The Show Snmp commands allow you to display the SNMP configuration. This
includes the SNMP manager, users, trap version, trap user, and whether SNMPv2 is
enabled (see Show SNMP, on page 157).
Example
Use the following command to display the list of SNMP users (admin user level 3
required).
Type show snmp user and press Enter.
Note: Valid authentication key and privacy key characters include
numbers, upper and lowercase letters, and the character set :=?@_.
Do not use spaces in user names.
Secure Shell Protocol
Secure Shell Protocol (SSH) provides secure, encrypted communications and
services between hosts on unsecured networks.
Secure File Transfer Protocol
Secure File Transfer Protocol (SFTP) uses SSH to transfer files encrypting both
commands and data, including passwords, to provide secure transmission for
copying files.
172 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix C Specifications and Factory Defaults
This appendix provides mechanical and electrical specifications and factory defaults
for the TimeProvider 5000.
In This Appendix
Specifications
Factory Defaults
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 173
Appendix C Specifications and Factory Defaults
Specifications
Specifications
This section provides the specifications for the TimeProvider 5000 components and
input and output signals.
Mechanical
Table C-1. TimeProvider 5000 Mechanical Specifications
Parameter
Description
Mounting
19 in. Rack
Rack Mounting Position
For front mounting location unit protrudes 0.65 in /
1.651 cm
See Figure 3-3, Figure 3-4, and Figure 3-5 for
drawings with detailed chassis dimensions.
Width
17.24 in. / 438 mm
Height
1.73 in. / 44 mm
Depth
17.12 in. / 435 mm
Weight
9 lb. / 4 kg fully loaded
Environmental
Table C-2. TimeProvider 5000 Environmental Specifications
Parameter
Description
Operating Temperature
-5 to 45C, 23 to 113 F
Storage Temperature
25 to 55 C, 13 to 131 F
Operating Humidity
5% to 85% RH non-condensing
Storage Humidity
5% to 100% RH non-condensing
174 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix C Specifications and Factory Defaults
Specifications
Power
Table C-3. TimeProvider 5000 Power Specifications
Parameter
Description
DC Input Power
48 VDC / 60 VDC nominal, 0.75 A typical
(0.6A for -60VDC)
DC Recommended
Battery Feed Fuse
5 A, maximum
DC Power
36 W, typical
Serial Port
Table C-4. Serial Port Specifications
Item
Description
Connector Type
9-pin, female D connector
Connector Label
Craft
Interface
RS-232, data terminal equipment (DTE)
Baud Rate
57.6 Kbps
Data Bits
Parity Bit
None
Stop Bits
Flow Control
None
LAN Port
Table C-5. LAN Port Specifications
Connector
MGMT
098-00028-000 Revision A December, 2008
Description
RJ-45 (10Base-T/100 Base-T) - Supports telnet
sessions and SSH sessions over TCP/IP.
TimeProvider 5000 Users Guide 175
Appendix C Specifications and Factory Defaults
Specifications
Input Signals
Table C-6. Input Signal Specifications
Parameter
Specification
GPS
Requirement
Total gain should be between 25 dB and 35 dB,
including gain of antenna and loss of cable
Interface
SMA connector
E1
Type
G.703 Section 9 Framed E1
or G.703 Section 13 2048 kHz
Format
CAS or CCS, CRC4 enable/disable
Impedence
75 ohms
Connector
Mini-BNC coax
Output Signals
Table C-7. Output Signal Specifications
Parameter
Specification
PTP
Ports
Ethernet Small Form-factor Pluggable (SFP)
Optical 1000 Base-X
Electrical 100/1000 Base-T
10 MHz
Impedance
50 unbalanced
Amplitude
1.5 dBm to 4.5 dBm
Signal type
Sine
Connector
Mini-BNC
Phase Noise (minimum)
176 TimeProvider 5000 Users Guide
1 Hz:
10 Hz:
100 Hz:
1 kHz:
10 kHz:
100 kHz:
60 dBc/Hz
90 dBc/Hz
100 dBc/Hz
110 dBc/Hz
135 dBc/Hz
140 dBc/Hz
098-00028-000 Revision A December, 2008
Appendix C Specifications and Factory Defaults
Factory Defaults
Table C-7. Output Signal Specifications (Continued)
Parameter
Specification
1PPS
Impedance
50 unbalanced
Amplitude
2.0 Vpp
Signal type
Square Wave
Rise Time
< 20 ns
Connector
Mini-BNC
Pulse Width
5 s 10%
Factory Defaults
Table C-8. General and Communication Parameters
Description
Default Value
Value Range
Time-of-Day Source
GPS
GPS | SYSTEM
PTP Timescale
AUTO
AUTO | PTP | ARB
Telnet Firewall
Block
Allow | Block
ICMP Firewall
Allow
Allow | Block
SSH Firewall
Allow
Allow | Block
SNMP Firewall
Allow
Allow | Block
FTP Firewall
Block
Allow | Block
SFTP Firewall
Allow
Allow | Block
User #1 Name
admin
20 ASCII Characters
User #1 Password
symmadmin**
32 ASCII Characters, a Minimum of 8
User #1 Access level
admin
user | config |admin
IMC EIA-232 Port
57.6k-8-N-1
fixed
IMC IP Mode
Static
DHCP | Static
IMC IP State
Enable
Enable | Disable
IMC IP Address
192.168.0.100
Valid IPv4 Address
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 177
Appendix C Specifications and Factory Defaults
Factory Defaults
Table C-8. General and Communication Parameters (Continued)
Description
Default Value
Value Range
IMC Gateway Address
0.0.0.0
Valid IPv4 Address
IMC Network Mask
255.255.255.0
Valid IPv4 Mask
IP Intra Comm
B: 172.16.250.8
to
172.16.250.47
IP address ranges:
A: 10.0.250.8 to 10.0.250.47
B: 172.16.250.8 to 172.16.250.47
C: 192.168.250.8 to 192.168.250.47
Hostname
TP5000
20 ASCII Characters
Image
1, 2
Asset Number
20 ASCII Characters
SNMP Manager (Up to 5)
None
Address: Valid IPv4 Address
Engine ID: Max of 32 ASCII Characters
SNMP User (Up to 10)
None
Username: Max of 20 ASCII Characters
Security Level: noauth, auth, private
Auth Type: MD5, SHA
Auth Key: Max of 32 ASCII Characters
Private Type: DES, AES
Private Key: Max of 32 ASCII
Characters, Minimum of 8
SNMP Trap User
None
Username: Max of 20 ASCII Characters
Security Level: noauth, auth, private
Auth Type: MD5, SHA
Auth Key: Max of 32 ASCII Characters
Private Type: DES, AES
Private Key: Max of 32 ASCII
Characters, Minimum of 8
SNMP Community (Up to 10)
None
Name: Max of 20 ASCII Characters
Access: read | read-write
SNMP Trap Version
2, 3
SNMP V2 State
Enable
Enable | Disable
UTC to TAI offset
33
19 to 255
RADIUS Authentication
Disable
Enable | Disable
RADIUS Server IP Address
0.0.0.0
Valid IPv4 Address
RADIUS Server Key
None
Max of 32 ASCII characters
Remote Syslog Host
0.0.0.0
Valid IPv4 Address
Remote Syslog State
Disable
Enable | Disable
Local Alarm Log Buffer Size
100
0 to 100 Kbytes
178 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix C Specifications and Factory Defaults
Factory Defaults
Table C-8. General and Communication Parameters (Continued)
Description
Default Value
Value Range
Local Event Log Buffer Size
100
0 to 100 Kbytes
Local Command Log Buffer
Size
100
0 to 100 Kbytes
Local Security Log Buffer
Size
100
0 to 100 Kbytes
Auto-Sync
Enable
Enable | Disable
Table C-9. GPS and Input Port Parameters
Description
Default Value
Value Range
GPS Antenna Cable Delay
0 to 1,000,000,000 ns
GPS Position Mode
Auto
Auto | Manual
GPS Position
Lat N37:22:43.425
Long W121:55:34.815
Elevation - 13.7m
LAT = Ndd:mm:ss.ss or
Sdd:mm:ss.ss
LONG = Eddd:mm:ss.ss or
Wddd:mm:ss.ss
ELEV= hhhh.h height in meters
GPS Elevation Mask
10
0 to 45 degrees
Reference Criteria
Priority
Priority | SSM | Manual
Reference Override
Port 1
Port 1, Port 2
Input Reference
INP1
INP1 | INP2
Telecom Input Port 1 State
Disable
Enable | Disable
Telecom Input Port 1 Priority
1|2
Telecom Input Port 1 Frame
Type
2.048 MHz
2.048 MHz | CCS | CAS
Telecom Input Port 1 CRC
Disable
Enable | Disable
Telecom Input Port 1 SSM
State
Disable
Enable | Disable
Telecom Input Port 1 SSM Bit
4|5|6|7|8
Telecom Input Port 1 SSM PQL
Value
1 to 9
Telecom Input Port 2 State
Disable
Enable | Disable
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 179
Appendix C Specifications and Factory Defaults
Factory Defaults
Table C-9. GPS and Input Port Parameters (Continued)
Description
Default Value
Value Range
Telecom Input Port 2 Priority
1|2
Telecom Input Port 2 Frame
Type
2.048 MHz
2.048 MHz | CCS | CAS
Telecom Input Port 2 CRC
Disable
Enable | Disable
Telecom Input Port 2 SSM
State
Disable
Enable | Disable
Telecom Input Port 2 SSM Bit
4|5|6|7|8
Telecom Input Port 2 SSM PQL
Value
1 to 9
Table C-10. Output Port Parameters
Description
Default Value
Value range
10 MHz Output Port State
Enable
Enable | Disable
10 MHz Output Generation State
Normal
Warm-up | Freerun |
Fast-lock | Normal
1PPS Output Port State
Enable
Enable | Disable
1PPS Output Generation State
Normal
Warm-up | Freerun |
Fast-lock | Normal
Table C-11. PTP Grand Master Port IP Parameters
Description
Default Value
Value Range
IOCx-y IP Address
IOC1-1
IOC1-2
192.168.1.11
192.168.2.11
IOCx-y IP Mask
255.255.255.0
Valid IPv4 Mask
IOCx-y IP Gateway
0.0.0.0
Valid IPv4 Address
180 TimeProvider 5000 Users Guide
Valid IPv4 Address
098-00028-000 Revision A December, 2008
Appendix C Specifications and Factory Defaults
Factory Defaults
Table C-11. PTP Grand Master Port IP Parameters (Continued)
Description
Default Value
Value Range
IOCx Port Redundancy
(Bonding)
Enable
Enable | Disable
IOC IP State
Enable
Enable | Disable
Table C-12. VLAN Parameters
IOCx-y Address
IOC1-1
IOC1-2
192.168.1.11
192.168.2.11
IOCx-y Mask
255.255.255.0
Valid IPv4 Mask
IOCx-y Gateway
0.0.0.0
Valid IPv4 Address
ID
Priority
Mode
Disable
Enable | Disable
State
Disable
Enable | Disable
192.168.x.(10+index)
x=1 or 2
index=1 through 16
Table C-13. PTP Grand Master Common Parameters
Description
Default Value
Value Range
PTP IOCx-y Clock Identity
ff:ff:ff:ff:ff:ff:ff:ff
64-bit value
PTP IOCx-y Priority 1
128
0 to 255
PTP IOCx-y Priority 2
128
0 to 255
PTP IOCx-y Domain
0 to 255
PTP IOCx-y DSCP State
Disable
Enable | Disable
PTP IOCx-y DSCP value
4 to 252
PTP Sync Limit
7 to 7
PTP Announce Limit
3 to 3
PTP Delay Limit
7 to 7
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 181
Appendix C Specifications and Factory Defaults
Factory Defaults
Table C-13. PTP Grand Master Common Parameters (Continued)
Description
Default Value
Value Range
PTP State
Enable
Enable | Disable
PTP Max Number of Clients
500
1 to 500
Table C-14. PTP Grand Master Unicast Parameters
Description
Default Value
Value Range
PTP IOCx-y Unicast Negotiation
Enable
Enable | Disable
PTP IOCx-y Dynamic Unicast
Lease Duration
300
10 to 1000 seconds
PTP IOCx-y Static Unicast State
(A maximum of 10 clients can be
assigned)
Disable
Enable | Disable
PTP IOCx-y Static Unicast IP
Address
0.0.0.0
Valid IPv4 Address
PTP IOCx-y Static Unicast Clock
ID
ff:ff:ff:ff:ff:ff:ff:ff
64-bit Value
PTP IOCx-y Static Unicast VLAN
ID
0 to 4095
PTP IOCx-y Static Unicast Sync
Message Rate (2^y)
7 to 7
PTP IOCx-y Static Unicast
Announce Message Rate (2^y)
3 to 3
PTP IOCx-y Static Unicast Delay
Response Message Rate (2^y)
7 to 7
182 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix C Specifications and Factory Defaults
Factory Defaults
Alarm Default Values
Table C-15. GPS Port Alarm Parameters
Description
Default Value
Value Range
Bridging Time
900
100 to 100000
Alarm Delay Time
0 to 500000
Alarm State (for each alarm)
Enable
Enable | Disable
Alarm Severity Level (See
System Notification Messages,
on page 90)
098-00028-000 Revision A December, 2008
0 to 6
TimeProvider 5000 Users Guide 183
Appendix C Specifications and Factory Defaults
Factory Defaults
184 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
The GPS L1 Reference Antenna is one component of a complete line of GPS
accessories for your GPS antenna system provided by Symmetricom. These
accessories are designed to deliver precise GPS signals over a wide temperature
range and in harsh environmental conditions.
In This Document
Antenna Kits and Accessories
Installing the Antenna
Optional Accessories
Contacting Technical Support
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 185
Appendix D Installing the GPS Antenna
Antenna Kits and Accessories
Antenna Kits and Accessories
This section provides a list of antenna kits and accessories as well as descriptions
and associated part numbers.
Selecting the Proper Gain Antenna
When installing the GPS radio receiver, it is important to select the proper gain
antenna and coaxial cable that accounts for the insertion loss between the antenna
and the radio receiver to avoid under-driving or over-driving the radio receiver
antenna input. The gain required at 1575 MHz for a GPS radio receiver input is the
manufacturers specification for the radio receiver to acquire satellites, with some
level of signal degradation allowed.
L1 Antenna gains are usually specified as the minimum effective gain. Such
antenna gains can have 4.5 to 10 dB more signal strength at different satellite
azimuths and elevations, depending on their reception pattern. The GPS engine
requires a signal level at the antenna connector input of the chassis to be between
25 dB and 35 dB. This tolerance allows for the signal loss of the internal coaxial
cable and connectors. The optimal signal level at the radio receiver input is 30 dB.
All antenna kits include the GPS L1 antenna, mounting pipe, floor flange, transient
eliminator, pre-assembled coaxial cable (for antenna to transient eliminator), roll of
3M 2150 weatherproof tape, and a right angle adapter. All chassis, antennas,
transient eliminators, and in-line amplifiers have N-type connectors.
All antenna kits supplied use LMR-400, or equivalent, low-loss coaxial cable. Other
types of coaxial cable are available for GPS antenna applications; however, it is
imperative that you calculate the specific cable loss to ensure a signal level
between 25 dB and 35 dB at the antenna connector input. The L1 signal loss of
LMR-400 is 0.167 dB/meter. The L1 signal loss of a 90 V transient eliminator is
typically 0.25 dB.
GPS Antenna With a Low Noise Amplifier, 26, 40, or 48 dB
Symmetricom offers three versions of GPS antennas with 26, 40, or 48 dB internal
Low Noise Amplifier (LNA). These antennas, which are compatible with most
commercial GPS receivers, receive, amplify, and filter the L1 (1575.42 MHz) signal
from GPS satellites. The antenna is housed in a weatherproof package suitable for
permanent installation in an exposed location. For additional transient eliminator
protection requirements, you can install a 250B-90 Gas Tube transient eliminator in
series with the antenna coaxial cable.
The cable between the antenna and the TimeProvider 5000 cable should be kept to
the shortest reasonable length. Before using additional cables, verify that the total
antenna system gain is acceptable as described in the Selecting the Proper Gain
Antenna section of Appendix D. The tables listed below provide information about
the antenna:
186 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Antenna Kits and Accessories
Table D-1 lists the item number and provides a brief description of each antenna
Table D-2 provides specification information for GPS antenna with internal LNA
Table D-3 lists the item numbers and provides a brief description of the antenna
accessories available for the GPS series antennas.
Table D-1. GPS Antennas with Internal LNA
Part Number
Description
Minimum Cable Length
99013091-006
26 dB Antenna with 3 m + 3 m cable
3 m (10 ft)
99013091-013
26 dB Antenna with 3 m + 10 m cable
3 m (10 ft)
99013073-070
40 dB Antenna with 10 m + 60 m cable
30 m (100 ft)
99013074-150
48 dB Antenna with 10 m + 140 m cable
76 m (250 ft)
99013075-230
48 dB Antenna with 10 m + 220 m cable and
20 dB Amplifier
198 m (650 ft)
Table D-2 provides specifications for GPS antennas with internal LNA.
Table D-2. Specifications for GPS Antennas with Internal LNA
Characteristic
Specification
Mechanical
Mounting
4 holes, 1.75 in x 1.75 in (4.445 cm x 4.445 cm) centers,
0.25 in (0.635 cm) mounting holes
Diameter
3.5 in (88.9 cm)
Height
12.94 in (328.7 cm), including pipe mount
Weight
< 3 lbs (1.4 kg)
Environmental
Temperature
40C to +75C
Relative Humidity
100% Non-Immersed
Altitude
200 ft. (60 m) below sea level to 13,000 ft. (3962 m) above sea level
Electrical
Power
4.7 to 28 VDC (5 VDC Nominal)
Element
Right Hand Circular
Carrier
L1 (1545.42 MHz)
Bandwidth
10 MHz
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 187
Appendix D Installing the GPS Antenna
Antenna Kits and Accessories
Table D-2. Specifications for GPS Antennas with Internal LNA (Continued)
Characteristic
Specification
Noise Figure
< 2.5 dB
Output Impedance
50
Gain
Marine 26
Marine 40
Marine 50
26.5 dB 3 dB
40 dB minimum
48 dB minimum
Table D-3 lists the available accessories for GPS antennas with internal LNA.
Table D-3. 26 dB L1 GPS Antenna Accessory Kit
Part Number
Description
112-43400-00-3
Transient Eliminator, 90 Volts, 1.5 GHz, N-Type
12010210-000-0
Bracket Assembly, Antenna Mount Right Angle
12813080-000-0
Crimper Kit, LMR-400 (crimp tool, 2150 tape, LMR preptool,
10 each crimp N-type connectors)
Transient Eliminators
Symmetricom offers the FCC-250B-90-1.5NFNF Transient Eliminator for installations
that require antenna coaxial lead-in protection. The FCC-250B- 90-1.5NFNF
Transient Eliminator passes DC power and frequencies in the 1.5 GHz range with
non-downconverter L1 GPS antennas. In most installations, the transient eliminator
mounts near the point at which the antenna lead enters the facility. Table D-4
provides the transient eliminator specifications.
Table D-4. FCC-250B-90-1.5NFNF Specifications
Characteristic
Specification
Type
Gas
Response Time
< 2 nanoseconds
Impedance
50
Insertion Loss
< 0.25dB @ 1,575 MHz
VSWR
< 1.6:1 @ 1,575 MHz
DC Breakdown Voltage
90 Volts
188 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Antenna Kits and Accessories
Table D-4. FCC-250B-90-1.5NFNF Specifications (Continued)
Characteristic
Specification
Dissipation Capacity
10,000 Amperes, impulse 8/20 sec
Connector Type
N-Type
Temperature
55C to + 70C
Relative Humidity
100% Non-immersed
Altitude
200 ft. (60 m) below sea level to 13 000 ft. (3962 m) above
sea level
GPS L1 Inline Amplifier
The GPS L1 Inline Amplifier (570704-0002) option boosts the signal from the
antenna. Use this amplifier on LMR-400 cables that are longer than 650 feet; it
receives power from the GPS radio receiver through the antenna coaxial cable
connections. Table D-5 provides mechanical and electrical specifications for the
amplifier.
Table D-5. GPS L1 Inline Amplifier Specifications
Characteristic
Specification
Mechanical
Connectors, (In/Out)
N-Type
Gain
20 dB 2 dB
Dimensions, includes connectors
Length: 3.77 in (9.6 cm)
Electrical
Power
+4 VDC to +28 VDC
Current
< 10 mA
Noise Factor
< 3 dB
GPS L1 Inline Amplifier Assembly
This assembly (item number 11013077-000-0) mounted on an aluminum plate is
designed with mounting holes to allow for several mounting configurations. The
assembly consists of a GPS inline amplifier, a 90 V L1 Transient Eliminator, and an
adapter for connectivity.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 189
Appendix D Installing the GPS Antenna
Antenna Kits and Accessories
Antenna Coaxial Cables
Symmetricom provides several low-loss cable types, as well as LMR-400 with
N-type connectors on both ends. Before using additional cables, verify that the total
antenna system gain is acceptable as described in the Selecting the Proper Gain
Antenna section of Appendix D.
Table 2-4 in Chapter 2 of this Users Guide lists the optional antenna coaxial
cables
Table D-6 provides antenna cable specifications
Table D-6. Antenna Cable Specifications
Cable Type
Measured Loss
(@1.575 GHz dB
per foot)
DC Resistance
( per foot)
Type Center
Conductor
Flammability
RG213/U
(Belden 8267)
0.093 dB
0.0030
Stranded 13 AWG
U/L CSA
RG213/U
(Belden 8267)
0.093 dB
0.0030
Stranded 2.62 mm2
U/L CSA
UHF/VHF
(Belden 9913)
0.058 dB
0.0027
Solid 10 AWG
UHF/VHF
(Belden 9913)
0.058 dB
0.0027
5.26 mm2
UHF/VHF
(Belden 89913)
0.089 dB
0.0027
Solid 10 AWG
Plenum U/L
CSA
UHF/VHF
(Belden 89913)
0.089 dB
0.0027
5.26 mm2
Plenum U/L
CSA
LMR-400
0.051 dB
Shield 0.00165
Center 0.00139
0.109 inch Solid
LMR-400
0.051 dB
Shield 0.00165
Center 0.00139
0.27686 cm2 Solid
190 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Installing Antennas
Installing Antennas
This section provides a procedure for installing a GPS antenna. Before beginning
the installation, review Planning the Installation, on page 191, and gather the
necessary tools and materials described in Antenna Installation Tools and Materials,
on page 194
Antenna Connection Overview
The TimeProvider 5000 chassis has one antenna connection located on the front of
the IMC module. The antenna connection is made via a SMA connector, labeled
GPS. The connectors are DC isolated and AC bypassed to frame ground. This
connection is used for a radio receiver antenna connection only. Installation
procedures for GPS antennas are outlined below.
Planning the Installation
Prior to installing the antenna, you should plan the site, antenna location, grounding
scheme, cable route, and all other details.
Locating the Antenna
Use Figure D-1 as a guide to locating the antenna.
Figure D-1.
Locating the GPS Antenna
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 191
Appendix D Installing the GPS Antenna
Installing Antennas
Caution: To avoid damage to the GPS antenna, do not place the
antenna where high-power radio signals are beamed directly at the
unit. Such signals can damage the preamplifier of the GPS antenna.
Warning: To avoid serious injury to personnel or damage to
equipment, exercise caution when working near high voltage lines.
In particular:
Use extreme caution when installing the GPS antenna near,
under, or around high voltage lines.
Follow local building electrical codes for grounding using the
frame ground lug on the TimeProvider 5000 chassis.
The in-line amplifier receives 5 VDC power from the GPS radio
receiver, and is supplied on the center conductor of the LMR-400
or equivalent coaxial cable. If the application requires an in-line
amplifier, mount the amplifier/plate assembly where the transient
eliminator would normally be mounted.
Symmetricom does not recommend cutting the antenna cables
provided in the GPS Antenna Kit.
Recommendation: Symmetricom recommends that you consider the
following location and environment influences before installing the
GPS antenna:
If possible, provide the antenna with an unobstructed 360-degree
view of the sky from the horizon.
In general, do not allow obstructions that obscure the horizon (as
viewed from the antenna) by more than 10 degrees, as shown in
Figure D-1.
Locate the antenna well away from, and preferably in a plane
above electrical equipment such as elevators, air conditioners, or
other machinery.
To reduce the risk of lightning damage, do not place the antenna at
the highest point of the building.
Locate the GPS antenna at least 12 feet from metallic objects, if
possible.
Locate the antenna high enough to avoid drifted snow.
Locate the transient eliminator in a protected area to avoid contact
with standing water.
Locate the antenna within 30 feet of the point at which the antenna
cable enters the building.
Allow at least 10 feet of separation distance between GPS
antennas.
Surfaces above the plane of the unit that are between the antenna
and the horizon can produce reflected (multi-path) signals, which
can degrade the performance of the radio receiver.
192 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Installing Antennas
Developing a Grounding Scheme
In addition to determining where to locate and mount the antenna and cabling, you
should develop a grounding scheme. The purpose of the grounding scheme is to
provide some protection against voltage surges and static discharge. If transient
eliminators are used, they also need to be connected to the perimeter ground
system or bulkhead entrance panel that is connected to the perimeter ground
system.
Caution: To ensure proper grounding, observe these precautions
when installing the antenna:
Allow no sharp bends in the ground conductors.
Ensure that no painted surface insulates the transient eliminator or
grounding clamps.
Ensure that ground conductors are bonded to the metal enclosure
box (if used) and do not enter through an access hole.
Do not use soldered connections for grounding purposes.
Secure all grounding connections with mechanical clamp type
connectors.
In general, follow local building codes when selecting a grounding scheme, wire
size, and installation.
Use #6 AWG (13.3 mm) copper ground wire or larger, depending on the distance
to the earth ground electrode. Refer to your local electrical codes for specific
details. In most cases, 1/0 AWG (55.0 mm) ground wire will maintain 1/10 the
resistance of the coaxial shied..
Note: Larger ground conductors provide better transient elimination;
that is, the larger the ground conductor, the less likely the chance of
transients.
Connect transient eliminators, if part of the grounding scheme, to earth ground
through a conductor.
Symmetricom makes no recommendation as to whether to install transient
eliminators. Symmetricom can provide suitable transient eliminators as an option.
Note: Do not connect the outside transient eliminator ground to the
inside equipment rack ground. Doing so can defeat the protection
afforded by the transient eliminator.
Never connect antenna systems to the same earth ground connector as heating
and cooling systems, elevator or pump motors, or other motors or machinery
which can induce noise in the antenna system.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 193
Appendix D Installing the GPS Antenna
Installing Antennas
Antenna Installation Tools and Materials
These standard tools and materials are not supplied in the antenna kit, but may be
required for installing the GPS antenna. For a list of antenna kit contents, see Table
D-1.
Four each 0.25 in (6 mm) fasteners for installing the antenna floor flange
Extra cable ties or acceptable cable clamps
#6 AWG (minimum) copper ground wire
Eight-foot (2.9 m) ground electrode
Custom mounting plates, U-bolts, masonry bolt, and so forth, as needed for
mounting to a tower, roof, or wall of a building
A cable puller may be required for installing the antenna coaxial cable
Digital voltmeter (DVM)
Caution: To prevent damage to connectors, use caution while
pulling cable.
Caution: To avoid damage to the connectors, do not use the
connectors to pull the cable. If at all possible, avoid bundling the
coaxial cable with other cables (and possible noise sources). Use
appropriate cable-pulling devices when pulling the coaxial cable
through conduit or a weather head.
Cutting Antenna Cables
Symmetricom recommends that you coil excess cable to avoid gain mismatch
between the GPS antenna and the radio receiver. Coiling the excess cable also
allows you to use the factory-installed crimped connector.
Symmetricom does not recommend cutting the antenna cables provided in the GPS
Antenna Kits. If you must cut the cables, please ensure that the following
requirements are met.
Be aware of these cable and connector requirements before cutting antenna cables:
Cable Requirements The total cable length from the radio receiver to the
antenna must not be shorter than the minimum cable lengths indicated in the GPS
Antenna Kits (see Table D-1).
Connector Requirements The cables provided with the GPS Antenna Kit have
factory installed crimped connectors. If you cut these cables, you must supply and
add a connector. Symmetricom recommends that you use only crimp-style N-type
connectors in the Crimper Kit for this application.
194 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Installing Antennas
Installing the Antenna
This section provides installation procedures for installing the GPS antenna.
Note: Follow local building electrical codes when installing the GPS
antenna.
Figure D-2.
GPS Antenna Installation
To mount the GPS antenna:
To mount the antenna to any stable flat surface, use the floor flange supplied in
the GPS Antenna Kit. The mounting surface and the local building codes
determine the type and number of fasteners, screws, bolts, and so forth, that may
be required.
To mount the antenna on the side of a building or tower, use the optional right
angle mounting bracket (part number 12010210-000-0).
To secure the coaxial cable to the mast, use one or more 8-inch cable ties or
appropriate cable clamps.
Connecting the Cable to the Antenna
To connect the coaxial cable to the mounted antenna (see Figure D-2):
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 195
Appendix D Installing the GPS Antenna
Installing Antennas
1. Loosen the four screws securing the top of the antenna in place to gain access to the
connector.
2. Route the shorter antenna coaxial cable from the antenna through the floor
flange (in the lower half of the antenna base) to the unit.
Caution: To avoid damage to the connectors, do not use the
connectors to pull the cable. If at all possible, avoid bundling the
coaxial cable with other cables (and possible noise sources). Use
appropriate cable-pulling devices when pulling the coaxial cable
through conduit or a weather head.
3. Connect the cable to the antenna and run the cable from the antenna through the
slot of the floor flange.
Caution: To avoid damage to internal solder connections, do not
over-tighten the connector.
4. Replace the four screws to secure the top of the antenna in place with the cable
connected.
Installing the Transient Eliminator
If you are installing a transient eliminator, follow these guidelines:
Transient eliminators should be installed in accordance with your antenna system
grounding scheme
Mount the transient eliminator within 30 feet (9 m) of the GPS antenna
If required, mount a second transient eliminator near the GPS antenna
To install the transient eliminator:
Note: Step 6 in the following procedure cannot be done if you cut the
cable (as described in Step 1).
1. If necessary, cut the coaxial cable and install mating connectors (see Cutting
Antenna Cables, on page 194).
2. Using the DVM, measure the resistance between the center conductor and
shield to verify that the center conductor and shield are not shorted together.
3. Connect the longer GPS antenna coaxial cable to the transient eliminator.
196 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Installing Antennas
4. Connect the ground wire between the transient eliminator and the proper
grounding zone (building ground, master ground bar, or other) for the mounting
location.
Recommendation: Symmetricom does not recommend soldered
connections for grounding purposes. All grounding connections
should be secured with mechanical clamp connectors.
5. Wrap the connectors with weatherproof tape for added protection.
6. Verify that the antenna coaxial cable center conductor is not shorted to the shield of
the cable.
Installing the Antenna Cable
You should install the antenna cable from the transient eliminator to the
TimeProvider 5000 using the shortest route possible. Follow all applicable building
and electrical codes to ensure a water-tight and fire-resistant installation. .
Caution: To avoid damage to the connectors, do not use the
connectors to pull the cable. If at all possible, avoid bundling the
cable with other cables (and possible noise sources). Use appropriate
cable-pulling devices when pulling the cable through conduit or a
weather head.
Connecting the GPS Antenna
Before connecting the GPS antenna to the TimeProvider 5000, see Antenna
Connection Overview, on page 191. Then, follow the instructions below.
1. Before connecting the antenna coaxial cable to the TimeProvider 5000, test the
DC resistance between the center conductor and the shield using an ohmmeter.
The reading should be approximately 260 for an active GPS antenna.
If the actual reading is incorrect, you may have a shorted or open cable or transient
eliminator (if installed). Therefore, apply the same measurements directly to the
GPS antenna. This requires disconnecting the antenna cable at the antenna.
Note: The open-circuit range of an individual ohmmeter can cause
readings to vary among meters.
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 197
Appendix D Installing the GPS Antenna
Installing Antennas
2. Secure the free end of the antenna cable to the appropriate antenna connector
on the rear panel of the TimeProvider 5000 using the right angle adapter
provided with the antenna cable.
Recommendation: Symmetricom recommends coiling excess cable
to avoid gain mismatch between the GPS antenna and the
TimeProvider 5000. Coiling the excess cable also allows you to use
the factory-installed crimped connector.
Antenna Installation Completeness Checklist
To verify that antenna installation is complete:
Verify that all power and ground wires are installed correctly and securely
fastened.
Verify that all input and output cables are properly installed.
Verify that all antenna connectors are secure, tight, and weatherproofed.
198 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix D Installing the GPS Antenna
Optional Accessories
Optional Accessories
Table D-7 provides a list of optional accessories which may be used to mount or
install the TimeProvider 5000.
Table D-7. Optional Accessories
Part Number
551026-0038
Description
Cable EIA-232 shielded DB9P to DB9S, 5 ft. (1.5 m)
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 199
Appendix D Installing the GPS Antenna
Contacting Technical Support
Contacting Technical Support
If you encounter any difficulties installing or using the product, contact Symmetricom
Global Services:
U.S.A. Call Center
Symmetricom, Inc.
2300 Orchard Parkway
San Jose, CA 95131-1017
Toll-free in North America: 888-367-7966
Telephone: 408-428-7907
Fax: 408-428-7998
E-mail:
[email protected]Internet: http://www.symmetricom.com
Europe, Middle East, and Africa (EMEA) Call Center:
Symmetricom Global Services EMEA
Fichtenstr. 25
85649 Hofolding
Germany
Telephone: +49 700 3288 6435
Fax: +49 8104 662 433
E-mail:
[email protected]Internet: http://www.symmetricom.com
Latin America
Symmetricom Latin America
Ft Lauderdale, Florida, USA
Telephone: +1 305-895-4301
Telephone: +1 954 385 2416
Fax: +1 954 252 4031
email:
[email protected]Asia and Pacific Rim
Symmetricom Hong Kong Ltd
P.O. Box No. 71
Texaco Road Post Office
Hong Kong
Telephone: + 852 2405 5203
Fax: + 852 2405 5713
email:
[email protected]200 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Appendix E Software Licenses
This product contains licensed third party software, including software available
under the GPL licensing scheme. The text of each license is available in the
License folder located on the Product Information CDROM that is supplied with the
TimeProvider 5000. Additionally, you can obtain these licenses and the open-source
software by contacting Symmetricom Technical support at the following numbers:
Worldwide (Main Number): 1-408-428-7907
USA, Canada, Latin America including Caribbean, Pacific Rim including Asia,
Australia and New Zealand: 1-408-428-7907
USA toll-free: 1-888-367-7966 (1-888-FOR-SYMM)
Europe, Middle East & Africa: 49 700 32886435
An administrative fee may be charged to obtain the source code.
By using the TimeProvider 5000, the user agrees to the terms of these licenses.
In This Appendix
Third-Party Software
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 201
Appendix E Software Licenses
Third-Party Software
Third-Party Software
The following is a list of third-party software applications provided with the
TimeProvider 5000.
busybox-1.10.4
dropbear-0.50
dtc-1.0.0
elfutils-libelf-libs-0.108
ethtool-5
expect-5.42.1
glibc-2.5.90
iproute-20061002
iptables-1.3.7
libgcc-4.2.0
libpcap-libs-0.9.5
linux-2.6.20
logrotate-3.7
mtd-utils-20070514
net-snmp-5.1
pam-libs-0.79
pam-modules-0.79
pam_radius-1.3.16
pam_tacplus-1.2.9
popt-libs-1.10.2
sudo-1.6.8p9
syslogd-1.4.1
tcl-dev-8.4.6
tcpdump-3.9.5
tftpd-hpa-0.43
u-boot-1.1.6
zlib-libs-1.2.3
202 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008
Index
Numerics
10 MHz 20
1pps 20
250B-90 gas tube, installing 186
A
access level
changing 64
displaying 64
setting 166
accessories
crimper kit 188??
GPS amplifier assembly 189
GPS antenna part numbers 188
GPS antenna transient eliminators 188??
L1 amplifier part number 189
miscellaneous 199
accessory part numbers 30
address
gateway configuration 61
IP 27
IP configuration 61
static IP configuration 66
subnet mask configuration 61
alarms
display status information 71
enable/disable procedure 70
provisioning 28
altitude specifications
GPS antenna 187
antenna
descriptions 187
GPS, connecting 197
installing 195
installing GPS 196
L1 gains, minimum 186
antenna cable
installing 197
asset tag 71
authentication key 75
authentication protocol
CBC-DES 73
HMAC-SHA-1-96 73
authentication scheme 65
B
basic configuration 30
components required 30
see also redundant configuration
blank panels 30
cutting 194
requirements 194
coaxial signal loss 186
installing GPS antenna 196
LMR-400 186
cautions defined 17
CBC-DES 73
CLI Commands ??166
CLI protocol 26
coaxial cables. <Emphasis>See cable
command
GPS 119
reboot 72
set alarm config 70
set configuration 72
set io 69
set redundancy 67
set snmp 74
set tod-source 69
show alarm 70
show alarm config 70
show log alarm 71
show log event 72
show snmp 75
show status 71
Command Line Interface (CLI) 104
commands, alphabetical listing
description 107
communications ports
IMC management Ethernet 26
IMC serial 26, 60
component part numbers 30
configuration
see also non-redundant configuration
basic components required 30
gateway address 61
IP address 61
redundant 30
subnet mask address 61
configuring
serial port 21
connecting the GPS antenna 197
connections
DC power 51
ethernet management port 43
GPS 45
grounding 48
serial port 44
connectors
GPS input 43
IMC 26
management ethernet 43
requirements 194
serial port 43
crimper kit
GPS antenna 188
crimp-style connectors, requirements 194
cutting coaxial cables, requirements 194
cable
appropriate cable-pulling devices 194
coaxial
098-00028-000 Revision A December, 2008
TimeProvider 5000 Users Guide 203
Index
DO
grounding connections 48
D
DC power connections 51
default IP address 61
DHCP mode
enable 66
direct connect cable 21
documentation, related 18
E
EIA-232 connector pin assignments 22
EIA-232 serial connection 20
EIA-232, see serial port
electrical specifications
GPS antenna 187
GPS L1 inline amplifier 189
electromagnetic compatibility (EMC) 37
electrostatic discharge (ESD) 37
environmental specifications
GPS antenna 187
Ethernet Management 20
ethernet management port
connections 43
ethernet port 27
F
firmware 83
fuse, branch over-current protection 36
fuse, internal 82
fuses, not field-replaceable 82
G
gain, GPS antenna 188
gateway address 66
gateway address configuration 61
GPS
antenna connection 26
connections 45
input connectors 43
reference provisioning 68
GPS antenna
accessories 188
caution near high voltage lines 192
connecting 197
crimper kit 188
installation 195
tools and materials 194
installation recommendations 192
installing 195
installing cable 197
low noise amplifier 186
part numbers 32
with internal LNA 186
GPS antenna kits 32
GPS command 119
GPS input signal 20
GPS L1 amplifier 189
assembly 189
specifications 189
204 TimeProvider 5000 Users Guide
H
HMAC-SHA-1-96 73
host address setup 66
I
I/O module 20
I/O ports 20
IMC communications ports 26
IMC connectors 26
IMC module LEDs 26
input signal, GPS 20
installation
completeness checklist, antenna 198
preparing site 191
transient eliminators 196
installing
GPS antenna cable 197
installing the GPS antenna 195
IOC module LEDs 26
IP address
default 61
IP address configuration 61
static 66
L
LEDs
IMC module 26
IOC module 26
LNA. See GPS antenna
local login 65
low noise amplifier. See GPS antenna
M
management ethernet connector 43
mask address 66
materials and tools
GPS antenna installation 194
mechanical specifications
GPS antenna 187
GPS L1 inline amplifier 189
module slots
vacant 30
module, I/O 20
mounting
bracket assembly 188
configurations, GPS L1 inline amplifier 189
GPS antenna specifications 187
N
notes defined 17
O
ordering
GPS antenna accessories 188??
098-00028-000 Revision A December, 2008
Index
PW
P
panels
blank 30
part numbers
antennas 187
component and accessories 30
crimper kit, GPS antenna 188
GPS antenna 32
passwords 63, 64
pin assignments, EIA-232 22
ports, I/O 20
power
GPS antenna specifications 187
power connections
DC 51
preparing antenna site installation 191
privacy key 75
product overview, TimeCreator 1000 19
protocol
CLI 26
SNMP 26
provisioning
alarms 28
purpose of this guide 14
R
RADIUS 65
reboot command 72
recommendations defined 17
redundant configuration 30
components required 30
see also basic configuration
redundant operation 47
reference provisioning
GPS 68
related documentation 18
relative humidity
GPS antenna 187
repairs 82
requirements, connectors 194
return material authorization number (RMA) 86
returning equipment 85
S
satellites
azimuths and elevations 186
gain required 186
security features, SNMPv3 73
security levels, described 61
serial connection
EIA-232 20
serial port
communication 60
configuring 21
connections 44
connector 43
service
technical assistance 36
set alarm config command 70
098-00028-000 Revision A December, 2008
set configuration command 72
set io command 69
set redundancy command 67
set snmp command 74
set tod-source command 69
SFP transceivers 45
show alarm command 70
show alarm config command 70
show log alarm command 71
show log event command 72
show snmp command 75
show status command 71
signal strength, antenna gains 186
Small Form-factor Pluggable 20
SNMP protocol 26
SNMPv2 75
SNMPv2c 73
SNMPv3 73
SNMPv3 Security Features 73
soldered connections 197
specifications
GPS antenna 187
GPS L1 amplifier 189
transient eliminators 188
static IP address
gateway setup 66
host setup 66
mask setup 66
static IP address configuration 66
structure of this guide 15
subnet mask address configuration 61
Symmetricom Global Services (SGS) 36
system status 71
T
technical assistance 36
temperature
GPS antenna specifications 187
Time of Day, setting 68
tools and materials
antenna installation 194
transient eliminators 188
GPS antenna accessories 188
installing 196
L1 signal loss 186
specifications 188
U
user access levels
displaying 64
UTI 20
V
vacant module slots 30
W
warnings defined 17
web address 18
TimeProvider 5000 Users Guide 205
Index
WW
206 TimeProvider 5000 Users Guide
098-00028-000 Revision A December, 2008