Translate This Page
Downloads
IOL Calculations
Optical Biometry
Home
IOL Power Calculations Bag vs. Sulcus IOL Power
Calculating Bag vs. Sulcus IOL Power printable version Search
Advanced search
Calculating Bag vs. Sulcus IOL Power.
If during cataract surgery, the decision is made to place the intraocular lens in the ciliary sulcus, rather than the capsular bag, a decrease in lens power is often necessary. This is due to the fact that as the optic is shifted more anterior (moved closer to the cornea), its "effective power" increases. The amount of this change is dependent on the "base power" of the intraocular lens. The greater the power, the greater the difference. Below is a chart for which this calculation has been made over a standard range of base powers from +30.00 D to +5.00 D. The central corneal power is assumed to be in the normal range. The capsular bag effective lens position (aka: ACD) is assumed to be 5.20 mm (as with the popular Alcon MA60AC), but these numbers will work with almost any modern posterior chamber intraocular lens. The effective lens position for the ciliary sulcus is estimated to be 4.70 mm. It is recommended that this information be available in the operating room as a handy reference for whenever this situation arises. Power at Capsular Bag +30.00 D +29.50 D +29.00 D +28.50 D +28.00 D +27.50 D +27.00 D +26.50 D +26.00 D +25.50 D Power at Ciliary Sulcus +28.55 D +28.09 D +27.61 D +27.14 D +26.67 D +26.20 D +25.73 D +25.26 D +24.79 D +24.31 D +23.84 D +23.36 D +22.89 D +22.42 D +21.94 D +21.47 D +21.00 D +20.53 D +20.05 D Bag / Sulcus Difference -1.45 D -1.42 D -1.39 D -1.36 D -1.33 D -1.30 D -1.27 D -1.25 D -1.22 D -1.19 D -1.16 D -1.13 D -1.11 D -1.08 D -1.05 D -1.03 D -1.00 D -0.97 D -0.95 D Subtract from Bag Power -1.50 D -1.50 D -1.50 D -1.50 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D
IOL Power Calculations Alcon AcrySof Toric IOL A-scan Biometry Bag vs. Sulcus Corneal Transplantation Effective Lens Position Haigis Formula High-Extreme Axial Myopia IOL Calculation Formulas Limbal Relaxing Incisions Outcomes Database Polypseudophakia Polypseudophakia Calculations Post Keratorefractive Surgery Pseudophakia Pseudophakic CFs Refractive Vergence Formula Silicone Oil Staphyloma Validation Guidelines Optical Biometry SIA Calculator
Disclaimer Physician Downloads Links References Special Thanks
+25.00 D +24.50 D +24.00 D +23.50 D +23.00 D +22.50 D +22.00 D +21.50 D +21.00 D
+20.50 D +20.00 D +19.50 D +19.00 D +18.50 D +18.00 D +17.50 D +17.00 D +16.50 D +16.00 D +15.50 D +15.00 D +14.50 D +14.00 D +13.50 D +13.00 D +12.50 D +12.00 D +11.50 D +11.00 D +10.50 D +10.00 D +9.50 D +9.00 D +8.50 D +8.00 D +7.50 D +7.00 D +6.50 D +6.00 D +5.50 D +5.00 D
+19.58 D +19.11 D +18.63 D +18.16 D +17.69 D +17.21 D +16.73 D +16.26 D +15.78 D +15.31 D +14.83 D +14.35 D +13.88 D +13.40 D +12.93 D +12.45 D +11.97 D +11.49 D +11.02 D +10.54 D +10.07 D +9.58 D +9.11 D +8.63 D +8.16 D +7.68 D +7.20 D +6.72 D +6.24 D +5.76 D +5.28 D +4.81 D
-0.92 D -0.89 D -0.87 D -0.84 D -0.82 D -0.79 D -0.77 D -0.74 D -0.72 D -0.69 D -0.67 D -0.64 D -0.62 D -0.60 D -0.57 D -0.55 D -0.53 D -0.50 D -0.48 D -0.46 D -0.43 D -0.41 D -0.39 D -0.37 D -0.35 D -0.32 D -0.30 D -0.28 D -0.26 D -0.24 D -0.22 D -0.20 D
-1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -1.00 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D -0.50 D No Change No Change No Change No Change No Change No Change No Change No Change No Change
TOP
Intraocular Lens Power Calculations
East Valley Ophthalmology, Arizona's premier eye specialists, provides this on-line information for educational and communication purposes only and it should not be construed as personal medical advice. Information published on this website is not intended to replace, supplant, or augment a consultation with an eye care professional regarding the viewer/user's own medical care. East Valley Ophthalmology's disclaims any
and all liability for injury or other damages that could result from use of the information obtained from this site. Please read our full Disclaimer
Home Eye Surgery IOL Power Calculations LENSTAR IOLMaster Eye Specialists Arizona Eyeglasses / Contact Lenses Arizona Plastic Surgery Arizona Copyright 2013 East Valley Ophthalmology. All rights reserved.