Chapter 1
What is light?
Light is that part of the electromagnetic spectrum that is perceived by our eyes.
What does the human eye see? Relative spectral brightness perception 1.0 0.8 0.6 0.4 Infrared Microwaves 0.2 350 450 550 650 750 Wavelength [nm] Wavelength [m] Night Day
10-5
100
105
Radio waves
By day we see in colour, while at night we can only see in shades of grey.
2 / Chapter 1
Light has a triple effect: Light for visual functions illumination of task area in conformity with relevant standards glare-free and convenient Light creating biological effects supporting peoples biological rhythms stimulating and motivating Light for emotional perception pleasant lighting enhancing the interior design makes people relax and feel at ease
Chapter 1 / 3
I=
E=
Lux [lm/m2]=[lx]
L=
[lm/(sr*m2)]=[cd/m2]
solid angle into which luminous ux is emitted area hit by luminous ux visible areas of light source reectance of area 3.14 for diffuse surface areas
Abbreviation: Unit:
Phi Lumen
4 / Chapter 1
Luminous flux The luminous flux describes the quantity of light emitted by a light source. The luminous efficiency is the ratio of the luminous flux to the electrical power consumed (lm/W). It is a measure of a lamps economic efficiency.
lm
Luminous intensity The luminous intensity describes the quantity of light that is radiated in a particular direction. This is a useful measurement for directive lighting elements such as reflectors. It is represented by the luminous intensity distribution curve (LDC).
Abbreviation: Unit:
I cd
Candela
Illuminance Illuminance describes the quantity of luminous flux falling on a surface. It decreases by the square of the distance (inverse square law). Relevant standards specify the required illuminance (e.g. EN 12464 Lighting of indoor workplaces). Illuminance: flux (lm) E(lx) = luminous 2 area (m )
Abbreviation: Unit:
E lx
Lux
Luminance Luminance is the only basic lighting parameter that is perceived by the eye. It specifies the brightness of a surface and is essentially dependent on its reflectance (finish and colour).
The Lighting Handbook
Abbreviation: Unit:
L cd/m2
Chapter 1 / 5
Quality criteria
Changing lighting situations Personal control Energy efciency Daylight integration Light as an interior design element
N E W
Illuminance definition of terminology Each term corresponds to the new European standards (see Chapter 2 / 2). Illuminance maintenance value m: value that the illuminance level must not fall below in the visual task area. Visual task area: illuminance levels are specified for specific visual tasks and are designed for the area in which these may take place. If the precise location is not known, then the whole room or a specific working area is used to define it. The visual task area may be a horizontal, vertical or inclined plane. Area immediately surrounding the visual task area: here illuminance may be one level lower than in the visual task area (e.g. 300 lx to 500 lx). Maintenance factor: the initial value multiplied by the maintenance factor gives the illuminance maintenance value. The maintenance factor can be determined individually, and takes the installations reduction in luminous flux caused by soiling and ageing of lamps, luminaires and room surfaces into account. The maintenance schedule (the cleaning and maintenance intervals for the lamps and installation) must be documented. See also Chapter 8 / 20 on Economic efficiency calculation.
6 / Chapter 1
operating time
Maintenance value = maintenance factor x initial value
Cause luminaires without glare control very bright surfaces Effect loss of concentration more frequent mistakes fatigue Remedy luminaires with limited luminance levels blinds
reflective surfaces incorrect luminaire arrangement incorrect workstation position loss of concentration more frequent mistakes fatigue
Chapter 1 / 7
Light colour The light colour describes the colour appearance of the light.
Colour temperature Appearance ww nw tw up to 3,300 K 3,300 K 5,300 K above 5,300 K reddish white blue-ish Association warm intermediate cool
The light colour sets the underlying mood of the room! Colour rendition
Colour rendition index Ra 90 8089 7079 6069 4059 2039 Daylight LED Incandescent lamp Compact uorescent lamp Fluorescent lamp Mercury vapour highpressure lamp Metal halide lamp Sodium vapour highpressure lamp
banned or no longer recommended under EU Regulation 245/2009 (EUP), due to low efficiency and inappropriate colour rendering.
Application examples (minimum requirements for Ra): Ra 90: colour inspection Ra 8089: offices Ra 7079: electronics industry Shown on fluorescent and compact fluorescent lamps as well as high-pressure discharge lamps (high-pressure mercury vapour lamps, metal halide lamps and high-pressure sodium vapour lamps): Ra 60 69: assembly work Ra 40 59: fabrication shop Ra 20 39: warehouses Example 840: 8 Ra 80 40
8 / Chapter 1
Measuring illuminance
Mean illuminance is the arithmetic mean of the point brilliance levels measured with a luxmeter in a defined grid, under precisely specified conditions. Measuring instruments: description and precision L: maximum precision, tolerance 3 % A: high precision, tolerance 5 % B: average precision; tolerance 10 % (minimum requirement) Measuring conditions avoid external light/daylight (measure separately and subtract) check mains voltage and ambient temperature use new, burnt-in lamps (discharge lamps 100 h) Measuring grid and measuring level workplaces = 0.75 m; sports facilities (floor) = 0.03 m circulation areas, stairs, car parks (floor) = 0.03 m cylindrical illuminance = 1.2 m measuring grid: congruent triangles measuring grid not congruent with luminaire layout grid
Size of measuring field 1m 5m 10 m 50 m 100 m Grid element spacing 0.2 m 0.5 m 1.0 m 3.0 m 5.0 m
Chapter 1 / 9
Lighting technology
Under the new European standard for interior workplace lighting, EN 12464, (psychological) glare is assessed by the unified glare rating method (UGR), which is based on a formula for glare. It takes account of all the luminaires in a system contributing to the sensation of glare. UGR tables derived from this formula are provided by the manufacturers for glare rating. The Quickplan tables in Chapter 6 and the lighting catalogues contain reference values for specific room sizes. UGR = 8 log 0.25 Lb (1)
L2 P2 (2)
The UGR method takes account of all the luminaires in the system that contribute to the glare sensation (2) as well as the brightness of walls and ceilings (1). It produces a UGR index. The two methods the one set out in DIN 5035 and the one defined in EN 12464 produce comparable results. UGR limits (UGRL), that must not be exceeded: 16 19 22 25 28 technical drawing reading, writing, training, meetings, computer-based work craft and light industries heavy industry railway platforms, foyers
10 / Chapter 1
Quality class for nominal illuminance (lx) A 1000 750 500 <300 1 2000 1500 1000 750 500 <300 2 2000 1000 500 <300 3 2000 1000 500 <300
25
28
22
8 6 4 3
a hs
1
13
The previously used luminance limiting curve method defined in DIN 5035 assesses the mean luminance of the luminaires across a beam angle of 45 to 85. The new European standard sets UGR = 19 as the maximum permissible value for offices, which is equivalent to the luminance limiting curve for 500 lx in Quality class 1. Chapter 1 / 11
UGRL
8 103
16
19
3 4
Types of lighting
Direct lighting: highly directional strong glare reduction at certain angles dark ceiling (cave effect) limited flexibility of workstation layout energy efficiency on the task level
Indirect lighting: diffuse lighting conditions room gains in height glare-free workstations can be positioned anywhere low energy efficiency
12 / Chapter 1
Indirect/direct lighting: pleasant room impression high user acceptance good contrast ratios flexible workstation layout (indirect component > 60 %)
Mellow Light: recessed direct/indirect solution workstations can be positioned anywhere glare-free reduced luminance levels at all viewing angles gives impression of daylight in room
Chapter 1 / 13
Lighting concepts
The definition of individual visual tasks for the purpose of lighting design in a room, as provided for in the EN 12464 standard, opens up new perspectives for lighting design. The quantity and quality of light can now be specified exactly for any task area (see Chapter 2 / 2). TASK AREA lighting concepts are a customised tool to fully exploit the additional options provided. At the same time they offer financial scope that can be used to improve lighting comfort and enhance the room effect.
Visual function TASK AREA lighting concepts provide the right quantity of light of the best possible quality for every visual task. Uniformity, control of glare and reflections, good contrast rendition and shadow detail are consistently matched to the respective task. The lighting is not based on the room but perfectly adjusted to peoples needs. Emotional and biological effects Focusing the lighting onto clearly defined areas means saving investment and operating costs. The funds saved can be used to improve comfort and enhance the room atmosphere, for instance by exciting lighting accents, illuminated walls or dynamic lighting scenarios. Optimum energy efficiency Large buildings provide huge potential for optimisation of energy consumption. Lighting that is consistently focussed onto individual task areas reduces mean illuminance levels and therefore the average expenditure on energy. Savings can be further increased by using daylight-based lighting management and presence detectors.
14 / Chapter 1
Room-related lighting concepts take neither individual task areas nor different visual tasks into account. They are based on the most demanding task performed in the room. The position of the workstation is not defined, the entire room disposes of a uniform lighting quality.
Lighting focussed onto individual visual task areas provides for varied light design in the room. By illuminating walls, for instance, rooms can be designed to be much more open and attractive; dynamic lighting situations can enhance their visual quality.
Chapter 1 / 15
Humanergy Balance
Human aspects + Energy efficiency = Humanergy Balance The Humanergy Balance concept harmonises both aspects of lighting and makes it possible to assess them: ELI, the lighting quality indicator, takes their physical and psychological effects on people into account; LENI, the energy efficiency indicator, assesses the economic and ecological aspects of light.
Visual performance
E
Empowerment
B
Vista
D
Vitality
C
Visual comfort
16 / Chapter 1
Visual performance Lighting in conformity with relevant standards is decisive for ensuring that a visual task can be identified and the related activities can be carried out. Consideration of the traditional quality characteristics of lighting has a major impact on visual task performance. lighting level uniformity of illuminance colour rendition avoiding hard shadows contrast rendition physiological glare Vista In prestigious buildings, for example, light is not only needed for seeing but also enhances the looks of the interior. Light can provide guidance and make people accept the interior on account of the first visual impression they get. architectural design mental design guidance hierarchy of perception external appearance material luminaires protection type protection against harmful radiation Visual comfort Light is not only needed in the visual task area, but also for perception in the room. Rooms should be illuminated with uniform brightness and lighting balance. balanced brightness distribution varying luminance levels plasticity/modelling discomfort glare uniform illuminance in area around visual task sense of security artificial light complemented by daylight use of flicker-free ballasts
Chapter 1 / 17
Vitality Light significantly influences peoples activity and sense of wellbeing. Moreover, it has a positive impact on their health and may even enhance or influence biological processes. sense of well-being activation and stimulation circadian rhythm lighting similar to daylight avoiding danger spots avoiding thermal radiation electromagnetic fields Empowerment Varying visual requirements, visual tasks or periods of use call for options to individually influence ones lighting situation. Sensors and control systems help users adjust the lighting situation to their personal needs. individual influence by switching and dimming choice of lighting scene presence detection daylight-based control choice of lighting scenarios flexibility for layout changes privacy Use of the charts is described in Chapter 8 / 411 Checklists.
18 / Chapter 1
{(Pn x FC) x {(tD x FO x FD) + (tN x FO)} [kWh/(year x m)] A Without elaborating on individual parameters in greater detail, the following relevant factors are identified: LENI =
the installed load (Pn) multiplied by the annual hours of use by day (tD) and at night (tN) reduced by factors ( 1) for daylight-based control (FD), presence-based control (FO) and use of a lighting control system (FC) the area assessed (A) LENI also takes charging energy for emergency lighting and standby energy into account. The following factors have a positive impact on the reduction of energy consumption: sensible control of lighting use of daylight use of presence detectors intelligent consideration of hours of use energy-efficient lamps need-based use of luminaires and lighting solutions, specified for the respective application constant lighting control (maintenance control)
60
The Lighting Handbook
120
0
Energy consumption in kWh/(m2 year)
180
Chapter 1 / 19
Chapter 2
2 3 12 3 37 7 8 8 89 9 10 11 11 12 13 15 13 13 13 13 13 14 14 14 14 15 15
Standard values for lighting of indoor and outdoor workplaces and sports facility lighting
m gives the illuminance maintenance values specified in the European standards which partially or completely replace national standards (e.g. DIN 5035, Austrian standard O 1040, Swiss lighting standard SLG 8912, DIN 67526). Lighting of indoor workplaces, EN 12464-1 (April 2003; is currently being revised) Lighting of outdoor workplaces, EN 12464-2 (October 2007) Sports facility lighting, EN 12193 (April 2008) (see also Definition of terminology, Chapter 1 / 6) Illuminance levels must not fall below the m maintenance values in the visual task area. If the precise location is not known, the limit should be applied to the whole room or a specific working area. Example for an office task area:
task
height = 0.75 m
area
use r
The maintenance factors 1.00 m can be determined on a case-by-case basis from the manufacturers data (see also Chapter 8). The maintenance factors and schedules for Zumtobel luminaires are given in the Quickplan tables (Chapter 6). Where no individual maintenance data is available, the following values are recommended as reference maintenance factors for modern technology and three-yearly maintenance: 0.67 in a clean atmosphere, and 0.50 in very dirty environments. EN 12464 specifies that the lighting designer must document the maintenance factor and maintenance schedule. UGRL is the upper limit for direct glare. The UGR value calculated in the design process must lie below this (the Quickplan tables give the UGR figure for the luminaire used in a medium-size reference room). Ra is the lower limit for the colour rendition index. The Ra of the selected lamp must be equal to or greater than this value. 2 / Chapter 2
oo r-a
rea
Em
UGRL
Ra
Chapter 2 / 3
Type of interior, task or activity Grinding of optical glass, crystal, hand grinding and engraving Precision work e.g. decorative grinding, hand painting Manufacture of synthetic precious stones Chemical, plastics and rubber industry Remote-operated processing installations Processing installations with limited manual intervention Constantly manned work places in processing installations Precision measuring rooms, laboratories Pharmaceutical production Tyre production Colour inspection Cutting, finishing, inspection Electrical industry Cable and wire manufacture Winding: large coils medium-sized coils small coils Coil impregnating Galvanising Assembly work: rough e.g. large transformers medium e.g. switchboards fine e.g. telephones precision e.g. measuring equipment Electronic workshops, testing, adjusting Food stuffs and luxury food industry Work places and zones in breweries, malting floor for washing, barrel filling, cleaning, sieving, peeling cooking in preserve and chocolate factories work places and zones in sugar factories for drying and fermenting raw tobacco, fermentation cellar Sorting and washing of products, milling, mixing, packing Work places and critical zones in slaughter houses, butchers, dairies mills, on filtering floor in sugar refineries Cutting and sorting of fruit and vegetables Manufacture of delicatessen foods, kitchen work, manufacture of cigars and cigarettes
Em
UGRL
Ra
750 1000 1500 50 150 300 500 500 500 1000 750 300 300 500 750 300 300 300 500 750 1000 1500
16 16 16 28 25 19 22 22 16 19 25 25 22 19 25 25 25 22 19 16 16
80 90 90 20 40 80 80 80 80 90 80 80 80 80 80 80 80 80 80 80 80 80
25 25 25 25 22
80 80 80 80 80
4 / Chapter 2
Type of interior, task or activity Inspection of glasses and bottles, product control, trimming, sorting, decoration Laboratories Colour inspection Foundries and metal casting Man-size underfloor tunnels, cellars, etc. Platforms Sand preparation Dressing room Work places at cupola and mixer Casting bay Shake out areas Machine moulding Hand and core moulding Die casting Model building Hairdressers Hairdressing Jewellery manufacturing Working with precious stones Manufacture of jewellery Watch making (manual) Watch making (automatic) Laundries and dry cleaning Goods in, marking and sorting Washing and dry cleaning Ironing, pressing Inspection and repairs Leather and leather goods Work on vats, barrels, pits Fleshing, skiving, rubbing, tumbling of skins Saddlery work, shoe manufacture: stitching, sewing, polishing, shaping, cutting, punching Sorting Leather dyeing (machine) Quality control Colour inspection Shoe making Glove making Metal working and processing Open die forging Drop forging Welding Rough and average machining: tolerances 0.1 mm Precision machining; grinding: tolerances < 0.1 mm Scribing; inspection
Em
UGRL
Ra
500 500 1000 50 100 200 200 200 200 200 200 300 300 500 500 1500 1000 1500 500 300 300 300 750 200 300 500 500 500 1000 1000 500 500 200 300 300 300 500 750
22 19 16 25 25 25 25 25 25 25 25 25 22 19 16 16 16 19 25 25 25 19 25 25 22 22 22 19 16 22 22 25 25 25 22 19 19
80 80 90 20 40 80 80 80 80 80 80 80 80 80 90 90 90 80 80 80 80 80 80 40 80 80 90 80 80 90 80 80 60 60 60 60 60 60
Chapter 2 / 5
Em
UGRL 25 25 22 19 25 25 22 19 25 25 19 25 25 22 28 25 25 16
Ra 60 60 60 60 80 80 80 80 80 80 80 80 80 80 20 40 80 60 80 20
20
6 / Chapter 2
Wire and pipe drawing shops; cold forming 300 Plate machining: thickness 5 mm 200 Sheet metalwork: thickness < 5 mm 300 Tool making; cutting equipment manufacture 750 Assembly: rough 200 medium 300 fine 500 precision 750 Galvanising 300 Surface preparation and painting 750 Tool, template and jig making, precision mechanics, micromechanics 1000 Paper and paper goods Edge runners, pulp mills 200 Paper manufacture and processing, paper and corrugating machines, cardboard manufacture 300 Standard bookbinding work, e.g. folding, sorting, gluing, cutting, embossing, sewing 500 Power stations Fuel supply plant 50 Boiler house 100 Machine halls 200 Side rooms, e.g. pump rooms, condenser rooms etc.; switchboards (inside buildings) 200 Control rooms 500 Outdoor switch gear 20 Printers Cutting, gilding, embossing, block engraving, work on stones and platens, printing machines, matrix making 500 Paper sorting and hand printing 500 Type setting, retouching, lithography 1000 Colour inspection in multicoloured printing 1500 Steel and copper engraving 2000 Rolling mills, iron and steel works Production plants without manual operation 50 Production plants with occasional manual operation 150 Production plants with continuous manual operation 200 Slab Store 50 Furnaces 200 Mill train; coiler; shear line 300 Control platforms; control panels 300 Test, measurement and inspection 500 Underfloor man-sized tunnels; belt sections; cellars etc. 50
19 19 19 16 16 28 25 25 25 22 22
80 80 80 90 80 20 40 80 20 20 40 80 80
Em
UGRL
Ra
Textile manufacture and processing Work places and zones in baths, bale opening 200 Carding, washing, ironing, devilling machine work, drawing, combing, sizing, card cutting, pre-spinning, jute and hemp spinning 300 Spinning, plying, reeling, winding 500 Warping, weaving, braiding, knitting 500 Sewing, fine knitting, taking up stitches 750 Manual design, drawing patterns 750 Finishing, dyeing 500 Drying room 100 Automatic fabric printing 500 Burling, picking, trimming 1000 Colour inspection; fabric control 1000 Invisible mending 1500 Hat manufacturing 500 Vehicle construction Body work and assembly 500 Painting, spraying chamber, polishing chamber 750 Painting: touch-up, inspection 1000 Upholstery manufacture (manned) 1000 Final inspection 1000 Wood working and processing Automatic processing e.g. drying, plywood manufacturing 50 Steam pits 150 Saw frame 300 Work at joiners bench, gluing, assembly 300 Polishing, painting, fancy joinery 750 Work on wood working machines e.g. turning, fluting, dressing, rebating, grooving, cutting, sawing, sinking 500 Selection of veneer woods 750 Marquetry, inlay work 750 Quality control, inspection 1000
25 22 22 22 22 22 22 28 25 19 16 19 22 22 22 19 19 19
60 80 80 80 80 90 80 60 80 80 90 90 80 80 80 90 80 80
28 28 25 25 22 19 22 22 19
40 40 60 80 80 80 90 90 90
Offices
Offices Filing, copying, etc. Writing, typing, reading, data processing Technical drawing CAD work stations Conference and meeting rooms Reception desk Archives 300 500 750 500 500 300 200 19 19 16 19 19 22 25 80 80 80 80 80 80 80
Chapter 2 / 7
Em
UGRL
Ra
Retail premises
Retail premises Sales area Till area Wrapper table 300 500 500 22 19 19 80 80 80
Educational premises
Nursery school, play school Play room Nursery Handicraft room Educational buildings Classrooms, tutorial rooms Classroom for evening classes and adults education 300 300 300 300 500 19 19 19 19 19 80 80 80 80 80
8 / Chapter 2
Type of interior, task or activity Lecture hall Black board Demonstration table Art rooms Art rooms in art schools Technical drawing rooms Practical rooms and laboratories Handicraft rooms Teaching workshop Music practice rooms Computer practice rooms (menu driven) Language laboratory Preparation rooms and workshops Entrance halls Circulation areas, corridors Stairs Student common rooms and assembly halls Teachers rooms Library: bookshelves Library: reading areas Stock rooms for teaching materials Sports halls, gymnasiums, swimming pools (general use) School canteens Kitchen
Em 500 500 500 500 750 750 500 500 500 300 300 300 500 200 100 150 200 300 200 500 100 300 200 500
UGRL 19 19 19 19 19 16 19 19 19 19 19 19 22 22 25 25 22 19 19 19 25 22 22 22
Ra 80 80 80 80 90 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
Chapter 2 / 9
Type of interior, task or activity Reading and colour vision tests with vision charts Ear examination rooms General lighting Ear examination Scanner rooms General lighting Scanners with image enhancers and television systems Delivery rooms General lighting Examination and treatment Treatment rooms (general) Dialysis Dermatology Endoscopy rooms Plaster rooms Medical baths Massage and radiotherapy Operating areas Pre-op and recovery rooms Operating theatre Operating cavity Intensive care unit General lighting Simple examinations Examination and treatment Night watch Dentists General lighting At the patient Operating cavity White teeth matching Laboratories and pharmacies General lighting Colour inspection Decontamination rooms Sterilisation rooms Disinfection rooms Autopsy rooms and mortuaries General lighting Autopsy table and dissecting table
Em
UGRL
Ra
500 300 1000 300 50 300 1000 500 500 300 500 300 300 500 1000
16 19 19 19 19 19 19 19 19 19 19 19 19 19
90 80 90 80 80 80 80 80 90 80 80 80 80 90 90
100 300 1000 20 500 1000 5000 5000 500 1000 300 300 500 5000
19 19 19 19 19 19 19 22 22 19
90 90 90 90 90 90 90 90 80 90 80 80 90 90
The Lighting Handbook
10 / Chapter 2
Em
UGRL
Ra
Transportational areas
Airports Arrival and departure halls, baggage claim areas Connecting areas, escalators, travolators Information desks, check-in desks Customs and passport control desks Waiting areas Luggage store rooms Security check areas Air traffic control tower Testing and repair hangars Engine test areas Measuring areas in hangars Railway installations Covered platforms and passenger subways (underpasses) Ticket hall and concourse Ticket and luggage offices and counters Waiting rooms 200 150 500 500 200 200 300 500 500 500 500 22 22 19 19 22 25 19 16 22 22 22 80 80 80 80 80 80 80 80 80 80 80
28 28 19 22
40 40 80 80
Sports facilities
The following details apply to competition class I (lower requirements apply to classes II and III) Em and Ra data according to European Standard EN 12193 General school sports data from EN 12464 An Ra level of 80 should be preferred For lighting for training purposes, usually an UGRL level of 22 should be observed Aerobics 500 Archery 200 Athletics (all disciplines) 500 Badminton 750 Basketball 750 Billards 750 Boccia 300 Boules 300 Bowling 200 Bowls 500 Boxing (competition/training) 2000/300 Climbing 500 Cricket 750 Cricket nets 1500 Curling (target/playing area) 300/200 Cycling 750 Dancing (fitness) 500 Darts 200
60 60 60 60 60 80 60 60 60 60 80 60 60 60 60 60 60 60
Chapter 2 / 11
Type of interior, task or activity Fencing Football (indoor) Gymnastics Handball Hockey Ice hockey Ice skating Judo Kendo/Karate Netball Petanque Racketball Riding Roller skating School sports Shooting Snooker Speed skating Squash Swimming Swimmung (school level) Table tennis Tennis Volleyball Weight lifting Wrestling
Em 750 750 500 750 750 750 750 750 750 750 300 750 500 500 750 200 750 500 750 300 500 750 750 750 750 750
Ra 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 80 60 60 80 60 60 60 60 60 60
12 / Chapter 2
Em
Ra
Airports
Hangar apron Terminal apron Loading areas Fuel depot Aircraft maintenance stands
Building sites
Clearance, excavation and loading Construction areas, drain pipes mounting, transport, auxiliary and storage tasks Framework element mounting, light reinforcement work, wooden mould and framework mounting, electric piping and cabling Element jointing, demanding electrical, machine and pipe mountings
Chapter 2 / 13
Em
Ra
Parking areas
Light traffic, e.g. parking areas of shops, terraced and apartment houses; cycle parks Medium traffic, e.g. parking areas of department stores, office buildings, plants, sports and multipurpose building complexes Heavy traffic, e.g. parking areas of schools, churches, major shopping centres, major sports and multipurpose building complexes 5 10 50 20 20 20
14 / Chapter 2
Type of area, task or activity Coupling area Stairs, small and medium-size stations Open platforms, inter-city services Covered platforms, suburban or regional trains or inter-city services with small number of passengers Covered platforms in freight areas, short duration operations Covered platforms, inter-city services Stairs, large stations Covered platforms in freight areas, continuous operation Inspection pit
Ra 20 40 20 40 20 40 40 40 40
Saw mills
Timber handling on land and in water, sawdust and chip conveyors Sorting of timber on land or in water, timber unloading points and sawn timber loading points, mechanical lifting to timber conveyor, stacking Reading of addresses and markings of sawn timber Grading and packaging Feeding into stripping and chopping machines 20 50 100 200 300 20 20 40 40 40
Extracts from Austrian Standard (NORM) EN 12464-1 Light and lighting lighting of workplaces Part 1: indoor workplaces (2003-04-01) Austrian Standard (NORM) EN 12464-2 Light and lighting lighting of workplaces Part 2: outdoor workplaces (2007-10-01) Austrian Standard (NORM EN 12193) Light and lighting sports facility lighting (2008-04-01)
The Lighting Handbook
published with permission by the Austrian Standards Institute, A-1020 Vienna, Heinestrasse 38 Ordering of standards and products, as well as research on the subject at www.on-norm.at
Chapter 2 / 15
Chapter 3
Products (selection)
Zumtobel applications . . . . . . . . . . . . . . . . . . . . . . . . LED luminaires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spots and tracks (VIVO, ARCOS, DISCUS, SUPERSYSTEM) . . . . . . . . . . 2LIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRAYON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PANOS (PANOS INFINITY LED, PANOS PureWhite and PANOS BioMotion, PANOS L and H, PANOS M/MWW, PANOS S, PANOS Q, PANOS range) . . . . . . . . . . . . . . FD 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PASO II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLOTLIGHT II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ELEEA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VAERO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AERO II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LIGHT FIELDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ECOOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAREENA LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MELLOW LIGHT V . . . . . . . . . . . . . . . . . . . . . . . . . . . CIELOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLARIS II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MIRAL 2 T16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FREELINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Free-standing uplights . . . . . . . . . . . . . . . . . . . . . . . SYSTEMLED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORILED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HELISSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TECTON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LINARIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SOLINA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VALUEA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PERLUCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCUBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLEAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZBOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ONLITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6 15 16 25 26 31 32 33
34 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 105
Areas of application
Throughout the world, ZUMTOBEL is the competent reliable partner for innovative lighting solutions in all areas of application of professional interior lighting providing global competence, superior product quality and futureproof technologies.
Industry and Engineering In production, the greatest demands are placed on the flexibility, functionality and building management system of industrial buildings. The right light in manufacturing and assembly bays as well as warehouses and workshops is the basis for any productive work. Offices and Communication Spatial structures and lighting systems must be adapted to new types of work. What is required are flexible people, flexible architecture and flexible light which enhances communication and motivation and improves the quality of working and spending time at the office. Education and Science Using light to enhance communication, improve awareness and create social understanding: dynamic lighting solutions with optimum colour properties enhance peoples concentration and improve visual comfort in educational facilities.
www.zumtobel.com/applications
Chapter 3 / 3
Presentation and Retail Modern retail worlds must provide a quality of experience, their design becomes an expression of the brand message. Customised lighting solutions incorporating LED technologies are an essential element of these worlds of experience. Hotel and Wellness Those who collect stars for their restaurant or hotel should not only work on their services. The guests pleasure starts with the lighting solution: light that stimulates all senses and makes guests feel at ease thanks to spotlights, recessed luminaires, light lines or innovative LED solutions. Art and Culture Where the highest architectural requirements must be met, ever greater demands are also made on light as a modulating, accentuating factor of experience: high-quality products and the latest LED technology for pure enjoyment of art.
4 / Chapter 3
www.zumtobel.com/applications
Health and Care Light increases the patients sense of wellbeing, creates a living-room ambience, supports the accomplishment of visual tasks in different therapies and examination procedures, makes orientation easier and ensures safety in circulation areas in hospitals, sanatoriums and retirement homes. Facade and Architecture People find the nightscapes around them created by illuminated building facades. These facilitate orientation, convey messages, communicate emotions and create attention. Lighting solutions by Zumtobel make it possible to style architecture, to highlight details or to radiate specific messages.
www.zumtobel.com/applications
Chapter 3 / 5
high colour stability efficient control thanks to simple control system low heat generation light without IR/UV
In comparison with lowvoltage halogen, light without IR/UV in particular, and consequently the absence of any heat radiation, is one of the main benefits. The energy efficiency of LEDs greatly exceeds that of low-voltage halogen luminaires. In comparison with compact fluorescent lamps, the benefits are slightly smaller. In addition to conservational lighting and long maintenance intervals, projected light is a main benefit. The light can be optimally directed into the area required by means of lens optics, which means that the illumination output can be used much more efficiently. Moreover, cove lighting in dynamic colours can be generated in a space-saving and energy-efficient manner, e.g. by means of LED RGB lighting solutions.
6 / Chapter 3
www.zumtobel.com/productsites
Today, the LED is less energyefficient than the following lamp technologies: fluorescent lamps: 80100 lm/W high-pressure halogen lamps: 90100 lm/W high-pressure sodium vapour lamps: 100120 lm/W LEDs: 4080 lm/W LEDs dont like high ambient temperatures. If LEDs are used at high ambient temperatures (e.g. sauna, etc.), this will strongly effect luminous flux and reduce the LEDs service life. High-performance LEDs generate a lot of heat at the board side. In order to ensure a service life of 50,000 hours for an LED luminaire, the boards must be properly cooled (e.g. cooling fins, ventilator or water cooling).
www.zumtobel.com/productsites
Chapter 3 / 7
luminaire luminous flux of 3300 lm as alternative to 4/14 W T16 stabilised white light with colour temperature of 3500 K colour rendering index Ra 90 luminaire efficiency 62 lm/W service life 50,000 hours at 70 % luminous flux glare limitation 65 L < 1500 cd/m2 and UGR < 16 recessed or surface-mounted luminaire with ceiling brightening
white
white hybrid luminaire with 48/60 W direct LED light and 2 x 2880 W T16 indirect light separately controllable direct and indirect light 23003600 lm direct LED light colour temperature 4300 or 6500 K luminaire efficiency up to 66 lm/W waveguide optic with MPO+ technology for glare control with steeply inclined displays individual luminaire or continuous-row luminaire luminaire luminous flux of 600 lm replaces 18 W fluorescent lamps or 50 W low-voltage halogen lamps luminaire efficiency 49 lm/W colour temperature 2700 K and 3500 K IP44 stable colour temperature service life 50,000 hours at 70 % luminous flux surface-mounted and emergency lighting version also available luminaire luminous flux: 2900 lm luminaire efficiency 60 lm/W colour temperature 2700 K and 3500 K IP44 stable colour temperature service life 50,000 hours at 70 % luminous flux white
white
* with 24 V and 350 mA luminaires, dimmability is dependent upon type of control gear!
8 / Chapter 3
www.zumtobel.com/productsites
Supply 230 V
Typical application Presentation and Retail Art and Culture Offices and Communication
Product
PANOS PureWhite
230 V
indoor application
Presentation and Retail Art and Culture Offices and Communication Hotel and Wellness Presentation and Retail Offices and Communication
PANOS BioMotion
230 V
indoor application
CAREENA
230 V
indoor application
AERO II Hybrid
230 V
indoor application
230 V
indoor application
www.zumtobel.com/productsites
Chapter 3 / 9
220 lm projected light as an alternative to 35 W low voltage halogen indirect RGB light for mellow downlight effect in dynamic colours
RGB + white
white luminaire luminous flux: up to 1000 lm (3000 K) luminaire luminous flux: up to 1150 lm (4200 K) projected LED accent light as an alternative to 75 W low voltage halogen 12 W spotlight (400 lm max.) with 15 or 30 W spotlight (1150 lm max.) with 25 beam angle system combines miniaturised, high-power LED spotlights for accent lighting with T16 lighting inserts for (direct and indirect) ambient lighting and wall lighting (wallwashing) LED light lines offer the possibility of room brightening and provide atmospheric special-effect lighting luminaire luminous flux: up to 289 lm per lighting head white RGB (light lines)
white luminaire luminous flux: up to 1000 lm (3000 K) luminaire luminous flux: up to 1150 lm (4200 K) projected LED accent lighting as an alternative to 75 W low-voltage halogen lamps 12 W spotlight (400 lm max.) with 15 or 30 W spotlight (1150 lm max.) with 25 beam angle dimmable on the spotlight via soft-touch control lenses available as lighting accessories optimised glare control lockable spotlight 510 cd 3000 K and 4000 K colour temperatures white
* with 24 V and 350 mA luminaires, dimmability is dependent upon type of control gear!
10 / Chapter 3
www.zumtobel.com/productsites
Supply 230 V
Typical application Presentation and Retail Art and Culture Offices and Communication
Product
24 V
indoor application
230 V
indoor application
VIVO LED
24 V 230 V
indoor application
SUPERSYSTEM
230 V
indoor application
ARCOS
switchable, dimmable
24 V
indoor application
www.zumtobel.com/productsites
Chapter 3 / 11
video-compatible lighting module from the CIELOS range RGB wall/ceiling mounted standard Plug & Play cluster including control and configuration
luminaire is part of the SCONFINE pendant luminaire series 3000 K colour temperature
white
high-intensity light line for illuminating surfaces and faades surface-mounted on ceiling, wall, floor (not recessed/ recessed in floor) adjustable bracket available as accessory
RGB continuous light line for indoor and outdoor lighting clear, diffuse or opal light line for illumination or as luminous line compact form with radial or axial leads lengths from 30 cm to 2.10 m
modular LED light line system for individual, slot and channel mounting not suitable for installation in floors
modular LED light line system for individual, slot and channel mounting SYSTEMLED Deco Basic optimised for cove lighting not suitable for installation in floors
* with 24 V and 350 mA luminaires, dimmability is dependent upon type of control gear!
12 / Chapter 3
www.zumtobel.com/productsites
Supply 230 V
Typical application Presentation and Retail Hotel and Wellness Offices and Communication
Product
CIELOS MOVE
switchable, dimmable
230 V
indoor application
SCONFINE SFERA
switchable, fully-DMX controllable, DMX-segment controllable Fully-DMX controllable, DMX-segment controlled, Fully-video controlled, Individual video-pixel controlled switchable, dimmable
230 V
HEDERA
24 V
24 V
Presentation and Retail Hotel and Wellness Offices and Communication Outdoor areas Presentation and Retail Hotel and Wellness Offices and Communication Outdoor areas Presentation and Retail Hotel and Wellness Outdoor areas
SYSTEMLED FLOOD
switchable, dimmable
24 V
SYSTEMLED DECO
switchable, dimmable
230 V 24 V
LEDOS M
www.zumtobel.com/productsites
Chapter 3 / 13
diffuser with transparent sides gives the luminaire unit a white blue floating appearance RGB model without frame also available
extremely easy wiring via self-tapping cable connector for indoor applications
glass only model available for indoor applications walk-over capacity to max. 1000 kg
walk-over capacity to max. 500 kg RGB models feature integrated DALI power supply unit also available as a wall-mounted version
white illuminance in accordance with EN 1838 for additional emergency lighting close to ground level unique lens/reflector optic ensures optimal light distribution on the floor available in colour temperature of 3000 K/5400 K strings of pixels for structuring surfaces custom pixel spacing is possible high illumination output thanks to 3 RGB LEDs in one pixel RGB
* with 24 V and 350 mA luminaires, dimmability is dependent upon type of control gear!
14 / Chapter 3
www.zumtobel.com/productsites
Typical application Presentation and Retail Hotel and Wellness Outdoor areas
Product
LEDOS B
switchable, dimmable
230 V 24 V
switchable, dimmable
230 V 24 V
switchable, dimmable
230 V 24 V 350 mA
230 V
switchable, dimmable
230 V 350 mA
ORILED
video controlled
Presentation and Retail Offices and Communication Hotel and Wellness Outdoor areas
CAPIX
www.zumtobel.com/productsites
Chapter 3 / 15
3-phase track high professionalism due to variety of switching options broad range of connectors for any type of track configuration track can be easily installed on ceiling or wall; suspension from cord or pendant tube tracks can be bent to specific radii; exception: tracks with supporting section acceptable: tracks used within manual reach
DALI track 3-phase track with built-in control lines for tapping DALI control signals spotlights with DALI control gear can be individually dimmed and switched at zero power, independent of power supply for each track, up to 64 DALI spots can be separately controlled impressive, dynamic shows and lighting sequences can be run in combination with the EMOTION touch panel by ZUMTOBEL
16 / Chapter 3
www.zumtobel.com/productsites
In lighting technology, tracks and continuous row lighting systems are vital components providing the basis for active light design. Using DALI, impressive lighting scenarios can be created. A fascinating
interplay of dramatic brightness variations can be staged, while spotlights fitted with colour filters allow to set the stage for pleasant choreographies of coloured light.
Design by EOOS
low-voltage halogen incandescent lamps up to 100 W metal halide lamps 20 W to 150 W high-pressure sodium discharge lamps up to 100 W wide range of accessories, also for lighting foodstuffs
Pros: interchangeable reflectors integral ball-and-socket joint universal 3-phase adapter by ZUMTOBEL Benefits: can be quickly adjusted to changing lighting tasks using a wide range of interchangeable reflectors safe, convenient operation thanks to ZUMTOBELs new universal 3-phase adapter intuitive, precise adjustment by means of integral clip
bayonet joint ensures minimum maintenance of lamps and easy replacement of reflectors and accessories installation on DALI tracks with DALI transformer, and appropriate DALI adapters for easy integration with digital lighting management systems Chapter 3 / 17
www.zumtobel.com/productsites
Product line + benefits: VIVO LED 12 W luminaire luminous flux: up to 400 lm replaces low-voltage halogen lamps up to 35 W 15 beam angle warm white (3000 K, colour rendering Ra > 90) intermediate white (4200 K, colour rendering Ra > 80) switchable or DALIdimmable
VIVO LED 30 W luminaire luminous flux: up to 1150 lm replaces low-voltage halogen lamps up to 75 W 25 beam angle warm white (3000 K, colour rendering Ra > 90) intermediate white (4200 K, colour rendering Ra > 80) switchable or DALIdimmable
18 / Chapter 3
www.zumtobel.com/productsites
VIVO-S and VIVO-SL Spotlight system with three hundred and sixty degrees precision
Models: recessed spotlight; spotlight head pivots from position flush with ceiling to 90 2 design sizes: round and square Pros for VIVO-S: pivots through up to 90 rotates through 360 pivots to position flush with ceiling pivots progressively Squeeze, Move and Retain (SMART) system for intuitive alignment Pros for VIVO-SL: freedom of design, also in case of low-profile ceilings pivots through up to 50 Squeeze, Move and Retain (SMART) system for intuitive alignment HIT G8.5 35/70 W and QT 90 W lamps electronic ballast must be ordered separately
Benefits: complete solution combining ceiling-mounted module and track highly flexible, architecturally consistent lighting concept
The Lighting Handbook
VIVO is a real all-rounder mastering every lighting task in shops and stores
www.zumtobel.com/productsites
Chapter 3 / 19
Benefits: unobtrusive, linear design control gear and accessory holder fit inside the spotlight housing innovative thermal properties (Cool Touch) ergonomic user interface for add-on functions (spotlight fixing and lamp focus adjustment, dimmable on the spotlight)
lamp glare control thanks to built-in anti-glare ring new 3-phase adapter: discreet shape, optimised handling, DALI-compatible via three-phase track comprehensive spotlight system and wide choice of accessories cater perfectly for a wide variety of lighting tasks
20 / Chapter 3
www.zumtobel.com/productsites
Models: for 3-phase and DALI tracks 4 sizes as standard spotlight, or with wallwasher attachment for premium accent lighting light sources: LED up to 30 W, low-voltage halogen up to 100 W, HIT up to 150 W
linear wallwasher for uniform illumination (T16, QT-DE, HIT-DE) projection spotlight with iris diaphragm or contour slider for sharp-edged points of light extensive choice of accessories
Standard versions
ARCOS 3
ARCOS 4 HIT
Wallwasher versions
ARCOS 1
ARCOS 2
ARCOS 3
ARCOS 4 HIT
Wallwasher versions
ARCOS WW HIT-DE
ARCOS WW T16
www.zumtobel.com/productsites
Chapter 3 / 21
DISCUS spotlight system Efficient retail area lighting using state-of-the-art light sources
Form follows LED for the first time ever, the design of the DISCUS spotlight has been geared towards LED technology and, thanks to its unobtrusively flat shape, it blends perfectly into any interior design scheme. Versions for HIT light sources round out the product range; track-mounted and ceiling-recessed spotlights allow for integral lighting solutions.
Design by EOOS
Benefits: unobtrusive design and flat shape innovative construction allows strictly passive cooling of the LED module efficient lighting concepts thanks to state-of-the-art light sources (LED and HIT) new track-box adapter for track-mounted spotlights: compact design and optimised handling
complete lighting solution thanks to the combination of track-mounted and ceilingrecessed spotlights spotlight rotates through 360, pivots through +/90
22 / Chapter 3
www.zumtobel.com/productsites
Models: 3-phase track-mounted spotlights ceiling-recessed spotlights (please order electronic ballast separately), single and double
LED 30 W HIT 20/35 W GU6,5 HIT 35/70 W G8,5 (all versions are available with same-diameter spotlight head) extensive choice of accessories
Surface-mounted spotlights
DISCUS LED
DISCUS HIT
Recessed spotlights
DISCUS-S E1 HIT
www.zumtobel.com/productsites
Chapter 3 / 23
SUPERSYSTEM is a compact, linear lighting system which is perfect for use in art and culture, and presentation and retail applications. Extremely disparate requirements can be met and hybrid solutions can be implemented within a project thanks to its flexible, modular design that uses various lighting inserts.
Design by Supersymetrics
Benefits: compact, miniaturised shape unobtrusive design premium look, functional but aesthetically pleasing highly flexible thanks to a wide variety of lighting inserts with LEDs and conventional light sources for accent and general lighting
LED lighting heads can be rotated, swivelled and completely recessed independently of each other
24 / Chapter 3
www.zumtobel.com/productsites
Models: SUPERSYSTEM H or S section for accommodating lighting inserts for direct and/or indirect lighting LED lighting heads, 2.5 W or 4.5 W (as single or triple module), available in 3 colour temperatures for efficient, flexible accent lighting T16 lighting insert for diffuse direct/indirect lighting T16 wallwasher optic LED Decoline Basic for indirect ceiling illumination
3-phase track for mounting spotlights SUPERSYSTEM pendant luminaire: hybrid solution with LED lighting heads and T16 SUPERSYSTEM ceilingrecessed downlight with LED lighting heads, single or quadruple SUPERSYSTEM 3-phase LED lighting unit with LED lighting heads, for use straight on 3-phase tracks
www.zumtobel.com/productsites
Chapter 3 / 25
2LIGHT MINI LED 2LIGHT MINI Pure White has a luminaire luminous flux of 1100 lm (3000 K and 4000 K)
2LIGHT MINI RGB/W 350 lm of projected light, direct LED light with RGB LED for a unique mellow downlight effect
2LIGHT MINI MINIATURE downlight system for accent lighting also available with LED Application: display lighting, restaurants, cafeterias, bars, reception areas, hotels, residential properties
2LIGHT-C MINI (CARDAN) MINIATURE downlight system for accent lighting maximum application flexibility thanks to integral pivoting lamp units Application: sales counters, small presentation areas, points of sale, shelf lighting
26 / Chapter 3
www.zumtobel.com/productsites
2LIGHT MINI surfacemounted MINIATURE downlight system for accent lighting surface-mounted housing can be installed quickly using CLIX mechanism Application: display lighting, reception areas, corridors, foyers and all other applications for which surface-mounted luminaires can be used
2LIGHT downlight system for widearea general lighting Application: reception areas, waiting areas, restaurants, corridors, foyers, conference rooms, relaxation areas, shopping arcades
2LIGHT-C (CARDAN) downlight system for accent lighting maximum application flexibility thanks to integral pivoting lamp units Application: shops, retail areas, presentation areas, museums
www.zumtobel.com/productsites
Chapter 3 / 27
Benefits:
Easiest possible maintenance/easy handling 2LIGHT has a completely closed housing. At the same time, 2LIGHT is light-tight in the ceiling. The unique EasyClean catch enables quick and easy relamping.
Unique technical lighting features innovative principle of reflector splitting diffuse light: a special matt-sanded plastic panel behind the safety glass ensures a matched soft light component around the reflector. Soft, pleasantly bright light is provided. direct reflector light: light component directed downwards via facetted reflector
28 / Chapter 3
www.zumtobel.com/productsites
Models:
2LIGHT (fixed)
2LIGHT MINI single module 2LIGHT MINI double module 2LIGHT MINI triple module 2LIGHT MINI surfacemounted 2LIGHT single module
www.zumtobel.com/productsites
Chapter 3 / 29
Type IP44
Module size
Mounting depth
Lamp(s)
Accessories
Protection class
Overview:
30 / Chapter 3
Colour filter Casting surround Mounting kit for thin ceilings Interchangeable reflectors Mounting kit for thin ceilings IP44 IP44 IP44 IP40 Colour filter Mounting kit for thin ceilings Colour filter Mounting kit for thin ceilings Colour filter Colour filter for soft light component IP44 Casting surround Mounting kit for thin ceilings Colour filter for soft light component IP44 Casting surround Mounting kit for thin ceilings
118 x 118 mm
100 mm
118 x 118 mm
120 mm
256 x 118 mm
103 mm
373 x 118 mm
103 mm
152 mm
LED WN/WW or LED RGB/W CDM-TM 20/35 W QT-LP to 50 W CDM-TM 20/35 W QT-LP to 50 W CDM-TM 20/35 W QT-LP to 75 W TC-TELI 1x32/42 W HIT-TC-CE 1x20/35/70 W
www.zumtobel.com/productsites
2LIGHT MINI single module 2LIGHT-C MINI double module 2LIGHT-C MINI triple module 2LIGHT MINI surface-mounted 2LIGHT/ 2LIGHT MDW single module 2LIGHT/ 2LIGHT MDW double module
408 x 216 mm
152 mm
600 x 216 mm
152 mm
Colour filter for soft light component IP44 Casting surround Mounting kit for thin ceilings
216 x 216 mm
152 mm
TC-TELI 1x32/42 W T-16 3x24 W HIT-TC-CE 1x20/35/70 W HIT-CE 3x35/70 W TC-TELI 1x32/42 W HIT-TC-CE 1x20/35/70 W
www.zumtobel.com/productsites
Colour filter for soft light component IP44 and directional light Casting surround Mounting kit for thin ceilings Interchangeable reflectors Colour filter for soft light component IP44 and directional light Casting surround Mounting kit for thin ceilings Interchangeable reflectors Colour filter for soft light component IP44 and directional light Casting surround Mounting kit for thin ceilings Interchangeable reflectors
408 x 216 mm
152 mm
Chapter 3 / 31
600 x 216 mm
152 mm
public buildings administrative buildings covered outdoor areas and damp locations supplementary red LEDs are added by a built-in sensorcontrolled system to ensure constant lighting quality throughout the luminaires 50,000-hour service life at 70 % luminous flux
32 / Chapter 3
www.zumtobel.com/productsites
A built-in sensor-controlled system adjusts red LEDs to ensure stable lighting quality throughout the luminaires service life.
www.zumtobel.com/productsites
Chapter 3 / 33
Application: PANOS INFINITY is an economically efficient alternative in any application area where 2/18 W, 2/26 W or 2/32 W compact fluorescent lamps are currently used.
Design: Thanks to its minimalist stylistic idiom, PANOS INFINITY embodies the spirit of our age.
34 / Chapter 3
www.zumtobel.com/productsites
luminaires with narrow white ceiling ring frameless luminaires for plasterboard or metal ceilings
Benefits: luminaire efficiency up to 77 lm/W 70 % more efficient than downlights using compact fluorescent lamps DALI-dimmable as standard (5100 %) highly efficient, passive thermal management modular lighting chamber system
service life 50,000 hours at 70 % luminous flux Stable White, with stabilised colour temperature PANOS INFINITY for office applications in accordance with EN 12464 symmetrical, wide-angle light distribution
Models: Stable White downlights with 3000 K or 4000 K > 1800 lm for 27 W or > 2400 lm for 36 W from luminaire Colour rendering Ra > 90
150 mm and 200 mm diameters two mounting depths: low is only 100 mm and high is only 140 mm four reflectors: facetted, highly specular, matt silver, white accessories: anti-glare ring for low models, IP54 glass (transparent), concrete casting surround
Tunable White downlights adjustable from 2700 K to 6500 K > 1800 lm from the luminaire colour rendering Ra > 85
www.zumtobel.com/productsites
Chapter 3 / 35
Application: corridors & foyers sanitary facilities (IP54 in closed ceilings, with accessories) offices (UGR 19) Benefits: replaces 1/26 W and 2/26 W fluorescent lamps but consumes significantly less power with a service life of 50,000 hours at 70 % luminous flux, the downlights are virtually maintenance free Models: luminous flux: 1100 lm and 2000 lm colour temperature: warm white (3000 K) and intermediate white (4000 K)
versions with 3000 K and 4000 K make it possible to select a colour temperature to suit a particular lighting situation models with a DALI interface allow easy dimming
36 / Chapter 3
www.zumtobel.com/productsites
PANOS BioMotion Based on RGB technology supplemented with white LEDs. Colour temperatures from 2700 K to 6500 K and a colour rendering index (Ra) of 80 can be set with a luminaire luminous flux of approx. 1000 lm. Application: high-profile prestigious areas (dynamic colour and colour temperature changes) offices & conference rooms (dynamic colour temperature changes in harmony with human biorhythms) Benefits: automatic readjustment ensures constant lighting quality and constant luminous flux throughout service life of 35,000 hours DALI signals from an EMOTION touch panel can be used to generate lighting scenarios in dynamic colours, or a colour temModels: reflector finishes: specular silver, matt silver, matt white Active membrane cooling in the case of PANOS Pure White 2000 lm and PANOS BioMotion ensures efficient thermal management.
shops & museums (different colour temperatures for different materials) hotels & wellness areas
perature spectrum which simulates natural changes of daylight over the course of a day this gives a precisely adjustable colour range that works in harmony with human biorhythms or a colour temperature that can be adapted to suit various surfaces
www.zumtobel.com/productsites
Chapter 3 / 37
HF/LF The precision-shaped facets provide brilliant effects, reduced luminance levels and optimum efficiency.
HG/LG Highly specular darklight reflector optic for glare-free working at the highest level.
HM/LM Good looks are guaranteed by this matt reflector optic with reduced dust sensitivity.
HL/LL The white reflector optic is a perfect match for the decorative accessories. Design by Sottsass Associati
38 / Chapter 3
www.zumtobel.com/productsites
HWW The special ribbed structure of the reflector produces asymmetrical light distribution, ideal for highlighting vertical surfaces.
Finest aluminium plating by sputtering Sputtering is a unique, highquality 4-chamber metallising process applied at high vacuum. Benefits: optimum lighting effect at high efficiency levels, perfect glare control and ideal light distribution high-quality appearance with darklight effect and iridescence-free reflector extremely easy maintenance and easy cleaning
Installation instructions No-tool installation The mounting ring made of die-cast aluminium is fitted without tools using spring clips. Combined refl./flange unit The reflector/flange unit is installed by means of a twist and lock mechanism without any tools. The ballast box has a rapid locking device and forms a pre-assembled luminaire unit with the reflector.
Precision detailing The excellent technical lighting characteristics of PANOS L and H reflector optics would be impossible to achieve if it were not for the exceptional accuracy of their injection-moulded components made of high-grade polycarbonate that direct the light. Zumtobel uses the sputtering method to coat the reflectors, regardless whether they are facetted, smooth or wallwasher reflectors. Aluminium is sputtered onto the plastic
The Lighting Handbook
in a high vacuum; then a very thin but extremely hard protective layer is applied. Compared to conventional vaporising or metallizing of surfaces with aluminium, sputtering ensures a significantly higher quality of the layer and a remarkable improvement in edge coverage. This unique metallisation process has set a new standard in the market. Other benefits include non-iridescence and easy cleaning using a cleaning cloth.
www.zumtobel.com/productsites
Chapter 3 / 39
With PANOS S fully swivelled out to 60, it is possible to illuminate a wall from its top edge.
As the lighting head and the housing are separately adjustable, specific areas can be shaded.
For illumination of different levels of shelving, PANOS S can be swivelled into the ceiling by up to 45.
Suitable reflectors for any situation Comparing light distribution/room: length 5 m, height 3 m Accent lighting by PANOS S150 with HIT G8.5
4 x PANOS S150 FL 70 W
500 700 900 1100 1300 1500
4 x PANOS S200 FL 70 W
500 700 900 1100 1300 1500
500
700
900
1100
1300
1500
www.zumtobel.com/productsites
Persuasive freedom of design various reflector optics: faceted, smooth, matt and painted various cover frames: white, titanium, chromium, frameless
PANOS Q Low
trendy attachments fitted as block or frame suspended attachment and technical lighting accessories
PANOS Q High
Frameless model
Attachments
Attachments
42 / Chapter 3
www.zumtobel.com/productsites
Less installation time PANOS no-tool quick installation shift & lock system for fixing cover frame quick and easy subsequent installation of attachements
Type PANOS L
PANOS H
Features high light output ratio, mounting depth only 100 mm, variety of surface finishes perfect glare control, DSE-compatible without attachment, illumination of vertical areas
PANOS M
100/150/200/250
PANOS M-V
100/150
Reflector optic Light distribution faceted, smooth, painted, matt faceted, smooth, painted, matt, wallwasher smooth, partly structrured flood
www.zumtobel.com/productsites
huge variety of light sources, consistent appearance, flat circular design internally swivelling (035) for uniform ceiling look general lighting with high wattages, housing light-tight uniform illumination of vertical areas, calm, uniform ceiling look uncompromising flexibility, can be swivelled in and out, highly convenient control for ceilings without mounting depth, reduced building and installation costs, large variety of surface finishes perfect one-piece reflector base, optimum, glare control (DSE-compatible), exceptional, design freedom (colours + attachments) approx. 1000 lm/1800 lm (lum. flux) of white light, or approx. 1000 lm (lum. flux) and variable 27006500 K in case of BioMotion
PANOS S
100/150/200/250
spot, flood
PANOS A
Surface-mounted
PANOS Q
190/190 250/250
Chapter 3 / 43
PANOS LED
150
Models + benefits: FD 1000 LF horizontal lamp position facetted reflector ceiling cutout: 200 mm lamps: 1 x 13/26 W, 2 x 13/26 W low-loss ballast/electronic ballast/EVG W3/LDE W5 NF 3/NA3/GET casting surround IP44 attachment, clear and opal decorative disc, decorative ring
44 / Chapter 3
www.zumtobel.com/productsites
FD 1000 M vertical lamp position ceiling cutout: 150 mm lamps: HIT G12 35/150 W HIT G 8,5 20/70 W HSTGX12 50/100 W meat/cold-meat filter (NUG) and UVA filter no-tool installation ceiling ring, white
FD 1000 S vertical lamp position ceiling cutout: 150 mm/200 mm lamps: HIT-CEG12 35/70/150 W HIT-TC-CE G8,5 20/35/70 W HST GX12 50/100 W QT 12 GY6,35 100 W meat/cold-meat filter (NUG) and IR/UVA filter spot and flood reflectors
www.zumtobel.com/productsites
Chapter 3 / 45
Application: shops & display windows galleries & showrooms hotels & wellness Benefits: flush with floor or overlapping frame without visible screw heads glass-only model models with reduced surface temperature to protect people and property 46 / Chapter 3
www.zumtobel.com/productsites
patented sealing system to protect against penetration of surface water various technical lighting accessories
Application: PASO II with LED technology powerful accent lighting spotlights and luminaires for impressive effects and orientation lighting LED luminaires for decoraPASO II everything in the right light Guiding light
tive lighting points, either static or with variable RGB colours luminaires with 3, 4 or 7 PowerLEDs for lighting columns with various spacings in between
Floodlighting PASO II extra low-profile design Use in screeded floors, without impacting on the structural calculations of concrete ceilings
Wallwashers
100 mm
PASO II accessories for an impressive yet safe presence colour filters for coloured honeycomb meshes for glare accent lighting control casting surround for quick IR blocking filters for reducing and safe installation surface temperature mounting kit for cavity floors/ anti-slip glass panel available hollow ceilings for fixing upon request PASO II luminaires with over- IP67 general-purpose box for lapping frame cover external control gear (PASO II S) www.zumtobel.com/productsites Chapter 3 / 47
SLOTLIGHT II The straight-ahead luminaire: from indoors to outdoors, even round the corner
This new light line hides the luminaire unit and instead relies on delivering an outstanding lighting effect. SLOTLIGHT IIs intelligent design makes mounting and installation significantly easier. It comes with all the features required for any type of mounting: recessed mounting, surface mounting and cord suspension. Complete product range: recessed, surface-mounted and pendant luminaire corner luminaires IP54 luminaires RGB LED luminaires LRO optic for task lighting versions with and without a frame Application: offices schools
Lighting technology/optics: PMMA optic provides virtually 100 % uniform lighting LRO optic for reduced luminance levels IP54: ideal for covered outdoor locations
48 / Chapter 3
www.zumtobel.com/productsites
The new light line boasts a 50 % improved light output ratio, and this figure can be boosted another 25 % by using an add-on reflector.
No reflections the Luminance Reducing Optic ensures optimal lighting conditions at the workstation.
Lamp arrangement:
A B C A
One luminaire or a continuousrow system running vertically or horizontally. A: single-length B: double-length C: triple-length and multi-length Notes regarding lamps: In the case of SLOTLIGHT II, uniformity is paramount. In order to achieve the best results in terms of uniformity, it is advisable to note the tips on the left regarding the arrangement of lamps.
The blue rectangle in the diagrams denotes the relevant manufacturers printed information.
A burn-in time of 100 hours at 100 % output is recommended in order to ensure optimal operation of for T16 light sources. The light source should be operated at 100 % output several times during its service life. Chapter 3 / 49
www.zumtobel.com/productsites
MPO optic
ELEEA meets the increasingly exacting requirements that are being placed on task lighting. Economic efficiency is the watchword, both in terms of investment and in use. With its tactically clever light distribution and high light output ratio levels, ELEEA makes a significant
contribution towards lighting quality, comfort and meeting green building and resource conservation requirements. This direct/indirect luminaire combines flexible functions and design options with a decidedly plain and unpretentious styling.
120
90
300
200
100
60
30 cd/klm 0
30
50 / Chapter 3
www.zumtobel.com/productsites
Benefits: Optimised, extremely wideangle light distribution for a minimum suspension height of 15 cm without any hotspots for low room heights. This ensures that the ceiling
is illuminated uniformly and, because of the shallow suspension height, the luminaire becomes part of the ceiling (patented upper reflector for indirect component).
Application: 75/25 direct/indirect light distribution for high light output ratio levels in excess of 90 % for maximum energy efficiency from < 2 W/m2/100 lx Optimised, very wide-angle light distribution for excellent uniformity and vertical illuminance, prevents cast shadows. This ensures technical lighting quality in the room (bright walls and ceilings) without compromising maximum efficiency. louvre optic for high efficiency (< 2 W/m2/100 lx)
LRO optic allows luminaires to be arranged freely in the room hybrid version with LED for indirect component and T16 for direct component; both components are dimmed separately single-lamp and twin-lamp luminaires in identical housings
Models: single and double lengths straight and L-connectors single-cord suspension pendant and surfacemounted luminaire louvre and LRO single-lamp and twin-lamp T16 28/35/49/54 W www.zumtobel.com/productsites Chapter 3 / 51
VAERO Waveguide luminaire providing soothing light for people and rooms
Design by Hartmut S. Engel Ingeniously designed VAERO waveguide luminaire with MPO lighting technology for maxiBalance between energy efficiency and lighting quality The sandwich construction of the micropyramidal optic lets the light really sparkle. Together with two other layers, mum energy efficiency. 2 designs available structured and homogeneous. it forms an optical system that ensures glare control in conformity with relevant standards at flat angles (EN 12464) and reduced luminance at steep angles.
52 / Chapter 3
www.zumtobel.com/productsites
The Photometric examination of new lighting systems research carried out at TU Ilmenau demonstrates that systems using MPO technology obtain excellent values with respect to contrasts in the room, in the task area and on the screen.
Via adjustable reflectors, the light distribution curve of the luminaires indirect component can be adjusted to the suspension height of the luminaire.
Contrasts in the room Brightness perceived at the workplace is determined not only by illuminance in fact, ceilings and walls have a
major impact, too. Balanced luminance levels create a pleasant, natural working atmosphere.
Contrasts between ceiling and luminaire Bright ceilings open up a room. The luminaires and their luminance levels blend
harmoniously into the brightness pattern of the ceiling. The variable pendant length of VAERO and adjustable indirect components are unique.
Contrast rendition in the task area Visual contrasts in the task area are determined by luminance ratios, e. g. ink colour on background.
The reduced luminance of the MPO diffuser helps to improve contrast rendition (see TU Ilmenau research).
Contrast rendition on screens In every location, and no matter what the angle of inclination, screens must remain
The Lighting Handbook
free from annoying reflections. Thanks to the MPO diffuser and reduced luminance , the viewability of computer screens is excellent.
www.zumtobel.com/productsites
Chapter 3 / 53
Benefits: brilliant LEDs take care of the more active, direct component T16 fluorescent lamps provide refreshingly indirect ambient lighting
highly perfected waveguide technology makes it possible to produce lighting solutions that offer maximum visual comfort, support for flexible workstation layouts and impressive energy efficiency
54 / Chapter 3
www.zumtobel.com/productsites
Application: when used in conjunction with an intelligent lighting management system, separately controllable direct and indirect light allow for a wide variety of lighting scenes waveguide technology with lateral injection of light hides the light source from direct view and allows maximum flexibility when positioning luminaires above workstations seamless MPO+ optic with precision-ground micro-
pyramids really lets the brilliant light shine and ensures appropriate glare control for a particular application. Ensures glare control at flat angles and reduced luminance levels at steep angles direct light with high-power LEDs: either highly efficient and stimulating with a colour temperature of 6500 K or pleasantly intermediate (4300 K) can be used as an individual luminaire or as part of a continuous-row system
AERO II T16 The sophisticated design and state-of-the-art waveguide technology of the T16-only version of AERO II are impressive.
Models: AERO II Hybrid with separately controllable LED direct light and T16 indirect light individual luminaire continuous-row luminaire LED direct light with a colour temperature of 6500 K or 4300 K
www.zumtobel.com/productsites
Chapter 3 / 55
Design by Sottsass Associati Pure innovation for the office Micro-pyramidal optic Even in surface-mounted and recessed luminaires, the sandwich construction of the micro-pyramidal optic ensures both glare control in conformity with standards and reduced luminance for direct illumination ideal for office lighting according to standard EN 12464.
56 / Chapter 3
www.zumtobel.com/productsites
Base
Available as recessed/surface-mounted/pendant/ free-standing or cluster luminaires, they are ideal for the more stylish office, with EN 12464 compliance over a range of ceiling heights and floor areas.
Recessed 1198 x 298 2/28 W T16 1498 x 298 2/35 W T16 598 x 598 4/14 W T16 1248 x 310 2/28 W T16 1548 x 310 2/35 W T16 623 x 623 4/14 W T16
Surfacemounted 1248 x 310 2/28 W T16 1548 x 310 2/35 W T16 623 x 623 4/14 W T16
ID pendant 1248 x 310 2/54 W T16 1548 x 310 2/49 W T16 623 x 623 4/24 W T16
LIGHT FIELDS model Recessed L-FIELDS E 4 x 4/14 W T16 L-FIELDS E 4 x 2/28 W T16 L-FIELDS E 4 x 2/28 W T16 L-FIELDS E 6 x 4/14 W T16 Surface-mounted L-FIELDS A 4 x 4/14 W T16 L-FIELDS A 4 x 2/28 W T16 L-FIELDS A 3 x 2/35 W T16 L-FIELDS A 4 x 2/28 W T16 L-FIELDS A 6 x 4/14 W T16
M 625
M 600
1-person office
2-person office
3-person office
www.zumtobel.com/productsites
Chapter 3 / 57
Complete product range: surface-mounted pendant luminaire continuous-row system Lighting technology/optics: indirect, direct and lateral light components direct light component is controlled using MPO+ technology Possible uses: can be arranged anywhere in the room thanks to MPO+ technology bright walls (vertical illuminance levels) thanks to Schools:
ECOOS Wallwashers Seating area
aluminium reflectors reduce luminance levels for lateral light wide-angle indirect light distribution via diffuserpearl material lateral light component shallow suspension height (35 cm) thanks to wideangle indirect distribution
Offices:
58 / Chapter 3
www.zumtobel.com/productsites
Reference room: room floor area 60 m2, room height 3 m, ECOOS pendant length 0.5 m, standard reflection factors 70/50/20, window 16 %
Reference room: axial dimension 1.35 m, room height 2.8 m, room depth 5.4 m, pendant length 0.4 m, standard reflection factors 70/50/20, window 16 %
www.zumtobel.com/productsites
Chapter 3 / 59
60 / Chapter 3
www.zumtobel.com/productsites
Innovative LED technology for the very highest levels of lighting quality and visual comfort
the unique system of white and red LEDs creates a perfect synthesis of high efficiency, extraordinary colour rendering and an intermediate colour temperature glare control is optimised for office lighting and is accompanied by high light output ratio thanks to patented MPO+ technology LEDs with a service life of 50,000 hours (L70) ensure minimal maintenance effort
Ceiling
Surface-mounted luminaire
Ceiling
Recessed or surface-mounted on ceiling with 10 % indirect light component for ceiling brightening.
www.zumtobel.com/productsites
Chapter 3 / 61
teamed with uncompromising lighting technology that achieves light output ratio levels of up to 87 %.
into the optic forms a seamless unit with the housing and conveys a contemporary feel.
62 / Chapter 3
www.zumtobel.com/productsites
unrivalled efficiency with light output ratio levels up to 87 % with fluorescent lamps minimal maintenance effort thanks to LED technology
Models: brightness optic for maximum energy efficiency MicroVane optic for tasks that involve exacting glare control requirements TC-L, T16 or LED light source square or linear
emergency lighting version with built-in LED emergency light for M625, M600 or M585 ceiling module for Tegular T15 systems all luminaires come with the LINECT plug-in connection system as standard
High-performance reflector highly efficient with a reflection factor of 99 % Brightness optik with lenticular diffuser or MicroVane optik LED or fluorescent lamp flexible choice of light sources
Cool Spot Cooler cools light source to optimum operating temperature Lighting chamber Soft Edge Prismatic (SEP) structure for mellow brightness distribution Emergency lighting version optional built-in LED emergency light Control gear dimsave as standard, optionally Dali or electronic ballast
www.zumtobel.com/productsites
Chapter 3 / 63
CIELOS Modular lighting module for creating designs for surfaces using light, colour and dynamism
Application: Luminous ceilings capture our attention. Wide-area, diffuse lighting fascinates the viewer. In combination with colour and dynamic changes, they are capable of radically altering the character of a room.
entrance areas conference rooms waiting rooms restaurant and catering areas shops and window displays
64 / Chapter 3
www.zumtobel.com/productsites
Models: Monochrome (1C): T16 version is just 80 mm high Bicoloured (2C): twocoloured T16 version Multicoloured (3C): multicoloured CIELOS for fluorescent lamps or with RGB LEDs CIELOS MOVE: videocompatible CIELOS a video control unit (VCU) is used to play back shapes, colours and images on it 150 mm high (up to 1C) 600 x 600 mm and 900 x 900 mm (2C and 3C only available in 900 x 900 mm size)
Application: Conventional luminous ceilings and light walls use almost no lighting technology at all. They rely exclusively on maximum clearance between lamp and diffuser in order to produce uniform illumination. CIELOS uses intelligent lighting technology and has a reduced mounting height of 8 or 15 cm CIELOS is a modular element and makes it easy to design relatively large surface areas: one module alongside another every module that is surrounded by other modules on all sides can be opened individually
coloured light: by using coloured fluorescent lamps with filters or richly coloured RGB LEDs its satin-frosted white glass adds a refined touch, does not distort colours and allows colour mixing in a wide-gamut colour space intelligent lighting control really brings the panel to life: EMOTION TOUCH and DALI or the video control unit for CIELOS MOVE can be used preconfigured packages for CIELOS MOVE make playing with dynamic changes, shapes and movement even simpler: these Plug & Play packages are supplied together with a controller and standard themes
www.zumtobel.com/productsites
Chapter 3 / 65
Optics for all applications: Darklight louvre specular louvre ensures ideal glare control according to EN 12464 Matt comfort louvre bright, friendly room atmosphere in conformity with EN 12464 standard Surface finishes: powder-coated titanium or natural anodised finish
Opal diffuser closed luminaire diffuse light distribution harmoniously soft light creates communicative room atmosphere
66 / Chapter 3
www.zumtobel.com/productsites
Practical technology Lamps are replaced straightforwardly from the top of the luminaire. Thanks to the convenient lever, releasing and replacing the light source is childs play. Installation: time is money Invisible height adjustment inside, adjustment in longitudinal direction
All inclusive Luminaire includes pre-installed suspension assembly, transparent connecting cable already fitted, light source already integrated, plus protective film Can be used for continuous row lighting CLARIS II configurations Continuous row luminaires (pendant luminaires): indirect/direct direct only indirect only wallwasher Connectors for continuous design
300 225 225 225 300 150 300
300
www.zumtobel.com/productsites
Chapter 3 / 67
68 / Chapter 3
www.zumtobel.com/productsites
Pre-assembly
Lay in
Fold up
Snap in
Packaging The packaging is part of the unique installation concept. The mounting brackets are accessible from the outside, even before the luminaire is unpacked. The benefit is that the luminaire will remain protected inside the packaging during pre-assembly.
Electrical connection Fast installation is also guaranteed thanks to a centrally located and easily accessible plug-in terminal block (CE compliant). The connecting cable can be installed conveniently and quickly without any need to open the luminaire housing.
Integrated light source MIRAL 2 is supplied with an LF840 light source (LF830 available on request). This not only minimises the time needed to install the luminaire, it also means that the time otherwise required to procure, transport and temporarily store the lamps can be saved too.
Protective film A special self-adhesive protective film made of recyclable material provides optimum protection against louvre and luminaire contamination. Thus, the MIRAL 2 surface-mounted luminaire can be fully installed while building work is still in progress and used to light the construction site.
www.zumtobel.com/productsites
Chapter 3 / 69
Lighting technology: matt bivergent louvre for optimum lighting conditions at the workstation Wattages: 1/54 W + 2 x 2/24 W T16 1/80 W + 2 x 2/24 W T16 2/54 W + 2 x 2/24 W T16 Models with electronic ballast, DALI-dimmable or dimming-on-demand function (LDoD)
Designed by: IOA (Ingenhoven Overdiek Architekten)/Dsseldorf Dimensions: length 2436 mm (54 W) or length 2736 mm (80 W) width 98 mm height 62 mm weight: 4.5 kg Material: extruded aluminium, natural anodised finish
Lighting technology: micro-pyramidal optic with glare-free light radiation characteristics Wattages: 2 x 1/49 W T16 2 x 1/54 W T16 2 x 1/80 W T16 Models with electronic ballast, DALI-dimmable or dimming-on-demand function (LDoD)
Designed by: IOA (Ingenhoven Overdiek Architekten)/Dsseldorf Dimensions: length 2436 mm (54 W) or length 3036 mm (80 W) width 98 mm height 62 mm weight: 4.5 kg Material: extruded aluminium, natural anodised finish
www.zumtobel.com/productsites
Chapter 3 / 71
LIGHT FIELDS-S Brilliant light thanks to innovative MPO+ technology Design by Sottsass Associati indirect/direct distribution asymmetrical indirect component 3/55 W or 3/80 W TC-L direct component via micropyramidal optic glare reduction L<1000 cd/m2 (3/55 W) reflector can be swung open for easy cleaning flat luminaire head made of anodised aluminium backlit decorative frame attached
MINIUM LITE Max. energy efficiency and reduced installed load Design by Engel & Zimmermann indirect/direct distribution 2 x 1/55 W or 2 x 1/80 W TC-L large direct component with cell louvre in darklight or matt comfort optic glare reduction L<1000 cd/m2 two separate luminaire heads made of anodised aluminium heads pre-assembled for extremely quick installation stand made of anodised aluminium U-shaped steel base
72 / Chapter 3
www.zumtobel.com/productsites
CAPA Maximum efficiency with a contemporary look indirect/direct light distribution 4/28 W TC-L or 4/55 W TC-L up to 50 % less installed load large direct component maximum light output ratio levels LOR > 90 % CAPA Plus offers maximum user-friendliness and ease of maintenance CAPA Lite has fewer convenience features SwitchDim and SensControl II allow users to adjust the lighting to suit their preferences. From simple switching and dimming through to fully automatic adjustment using presence detectors and brightness sensors, Zumtobel free-standing luminaires provide the right solution to meet any requirement.
OPURA MPO+ technology for great lighting convenience separately controllable direct and indirect light direct light from 28 W TC-L or LED indirect light from 55 W or 80 W TC-L seamless luminaire head pleasantly gentle stylistic idiom exceptionally uniform light emitting panel dimmable luminaire with soft-touch controls
SwitchDim Simple dimming and switching using a switch SensControl Fully automatic control of lighting based on daylight levels and presence detection
www.zumtobel.com/productsites
Chapter 3 / 73
SYSTEMLED is a modular LED system for decorative light lines or wide-area illumination of walls. Pre-assembled plugin connectors at the modules help to reduce sources of error during installation, and minimise installation effort. The use of aluminium sections ensures optimum cooling of LED boards, which is a prereq-
uisite to reach a service life of up to 50,000 hours! Varied accessories including a mounting channel, mounting springs and a diffuser provide for a wide range of applications. SYSTEMLED can be used in both indoor and outdoor areas.
Channel installation: No-tool wiring using cables with pre-configured connectors. Using special steel springs, the modules are fitted in the channel or wall and ceiling cut-out without the use of any tools.
74 / Chapter 3
www.zumtobel.com/productsites
Pre-assembled modules in various lengths allow to flexibly adjust the light lines to projectspecific sections. DECOLINE is perfect for illuminating coves and for creating
light lines uniformly illuminated by means of a diffuser. FLOODLINE provides uniform illumination of vertical areas (wallwashing).
Individual Slot Channel Diffuser* installation installation installation DECOLINE Basic DECOLINE IP40 DECOLINE IP65 FLOODLINE IP40 FLOODLINE IP65
* In DECOLINE IP40, the diffuser is clipped onto the LED module. For DECOLINE IP65, modules are supplied optionally with transparent or diffuse optic.
SYSTEMLED Deco Basic: Easy to install in the cove thanks to ready-to-connect modules inc. connecting cables.
www.zumtobel.com/productsites
Chapter 3 / 75
ORILED Decorative, with its warm or blue light colour, is used in areas where the focus is on a decorative lighting effect. By using different control gear, the luminaires can be easily integrated into building management systems such as LUXMATE or emergency lighting system.
In emergency cases, too, additional escape route lighting is ensured via a central battery or 1 h/3 h separate battery packs. With IP65 protection can be used for a broad range of applications. A variety of accessories is available for easy luminaire installation.
Besides its two 1 W LEDs, the secret of ORILEDs excellent illuminance is, in particular, its reflector combined with its unique lens optic.
76 / Chapter 3
www.zumtobel.com/productsites
By means of flexible mounting brackets, the luminaires are fixed in the wall cut-out, bollard, or in the surface-mounted housing, mounting frame or casting surround. The stainless steel frame is fixed to the luminaire housing via CAMLOCK fasteners. ORILED therefore has no visible screw heads.
www.zumtobel.com/productsites
Chapter 3 / 77
HELISSA Stylish appearance with individuality for indoor and outdoor areas
The decorative HELISSA wall/ceiling mounted luminaire with protection types IP40 and IP65 sets both indoor and outdoor areas masterfully centre stage while saving energy. In addition to round or square glare-free optics, a discreet indirect light component creates a white or coloured lighting corona on the wall or ceiling. Emergency lighting and dimmable models, too, can be easily installed and maintained.
HELISSA round Application: indoor areas such as corridors, stairs and waiting areas applications in temporarily or permanently humid/damp environments (e.g. station concourses) aggressive environments (chlorine or saline-containModels:
Model HELISSA IP40 Size D/Q 360 D/Q 450 HELISSA IP65 D/Q 360
HELISSA square ing environments, wellness areas) outdoor areas around the house, entrance areas public spaces All applications, from inside to outside, can be implemented in the same, highquality design using one luminaire range!
78 / Chapter 3
www.zumtobel.com/productsites
Lamp(s) 2/9 W TC-SEL 1/22 W T16-R 1/55 W T16-R 2/18 W TC-L 1/22 W T16-R 2/18 W TC-DEL
Benefits/pros: high-quality and efficient optimum materials for the respective application area: HELISSA IP40: sheet steel fitting, rugged polycarbonate diffuser HELISSA IP65: die-cast aluminium fitting, frosted glass diffuser glare-free and uniform illumination high energy efficiency; compact/fluorescent lamps operated exclusively with electronic ballast convenient and versatile easy installation HELISSA IP40: round fitting, diffuser unit (diffuser + aluminium frame) can be installed without tools thanks to twist and lock mechanism HELISSA IP65: round or square fitting with silicone seal and glass cover, cover frame is fixed without tools by means of CamLock fasteners
concealed screws decorative cover frame optionally in white, titanium or aluminium, brightly polished/with protective coating economically efficient and flexible luminaires are optionally switchable or analog/digitally dimmable models in all design sizes/ versions are available in the same design and size with built-in 1 h or 3 h emergency lighting unit all components are accommodated in the fitting All these features give HELISSA it is unmistakable individuality.
Accessories: Set of foil filters (red, blue, yellow) to create corona For more creative scope, the lighting coronas colour can be changed by fitting foil filters.
www.zumtobel.com/productsites
Chapter 3 / 79
TECTON Retail
TECTON-I Industry
80 / Chapter 3
www.zumtobel.com/productsites
TECTON provides flexibility Layout changes occur at ever shorter intervals in retail, business and industry, demanding maximum flexibility from any continuous-row lighting system. TECTON allows the luminaire modules to be placed anywhere on the trunking. Technical alterations to the lighting can also be made on site, with 11-pole wiring allowing any modifications in terms of brightness control or emergency lighting supply in conformity with relevant standards.
TECTON saves on installation costs The easier, the better. The specially designed power conductor integrated in the trunking revolutionises installation, making TECTON both versatile and easy to handle. Not only does this save time, but lower qualified and hence cheaper staff can do the work. All components can be combined logically and simply in the modular system, reducing TECTON installation costs by up to 60 percent through time savings, depending on the continuous row configuration chosen.
TECTON provides safety TECTON provides safety in several ways: At the design stage, by the integration of mains lighting, emergency lighting and control; By the clear separation of emergency and escape-sign luminaires in two emergency-lighting circuits; By the ONLITE emergency luminaire range that can be fully customized to the TECTON system for safety and reliability of the lighting solution in conformity with relevant standards.
www.zumtobel.com/productsites
Chapter 3 / 81
TECTON-H RBS The module for flexible lighting concepts: with the swivelling luminaire head, it is easy to respond to any changes in room layout. Thanks to wideangle lighting technology, retail islands can be created using directed light, also enabling optimum illumination of gondola heads.
TECTON-H RSR Making homogeneous illuminated areas and wall surfaces come alive: using lighting technology with asymmetrical distribution, it is possible to create lighting focuses and, for instance, precisely accentuate shelves.
TECTON-H R A high-pressure module that provides highlights: wide-angle or narrow-beam lighting technology strikingly emphasises seasonal and pallet goods using directional light, pinpointed and brilliant.
82 / Chapter 3
www.zumtobel.com/productsites
TECTON-H RSRA The surface-mounted model adds refreshing lighting accents for the illumination of counters and fresh goods. Light with asymmetrical distribution in combination with special accessories such as UVA, IR, meat and cold-meat filters makes the goods displayed appear delicious and tempting.
The wide-angle, purely indirect lighting characteristics of the indirect optic ensure uniformly illuminated ceilings, preferably in long corridor areas. Providing ambient lighting, it is also ideal for combination with accent lighting in retail areas.
The pool-light optic made of opal plastic impresses with harmonious, wide-area luminance levels on softly rounded surfaces. It is a perfect choice for wellness areas, sophisticated zonal lighting in retail areas, or cool ambient lighting at the bar.
www.zumtobel.com/productsites
Chapter 3 / 83
84 / Chapter 3
www.zumtobel.com/productsites
Benefits of LINARIA Seamless: lighting length is the same as the length of the luminaire itself the lampholder lift neatly sinks the light source into the luminaire excellent colour rendering (Ra 80) high luminous efficiency available in various wattages: 24, 39 and 54 W makes unbroken end-to-end light lines possible no discontinuity and no distracting shadows
single- or twin-lamp version linear appearance with identical wattages DALI-dimmable electronic ballast (24 W on request) housing made of high-grade aluminium through-wired batten luminaires/Seamless available on request (1/39 W and 1/54 W; 2 x 1/39 W and 2 x 1/54 W) is available as a pendant version or as a wall and ceiling-mounted luminaire
Enclosures for Seamless and T16 Clear enclosure transparent glass optic Diffuse enclosure made of diffuser-pearl material translucent (70:30 ratio) light source is concealed Longitudinally prismatic enclosure perfect longitudinal glare control suitable for use in task areas to limited extent
Benefits of LINARIA T16: single-length is available in all T16 wattages is available as a pendant version or as a wall and ceiling-mounted luminaire
The Lighting Handbook
housing made of high-grade aluminium highly resistant to mechanical stress thanks to powdercoated surface finish
www.zumtobel.com/productsites
Chapter 3 / 85
Design by Charles Keller Application: shop/retail, with focus on lighting fresh products architecture-centred luminaire with ceiling illumination Benefits: both lighting types, direct and indirect, can be separately switched and dimmed same lamp and reflector range as COPA D additionally reflector painted in titanium one unit variety of installation options (cord, pendant, chain, adapter) direct installation on the ceiling accessories: IP54 glass cover, prismatic glass cover 2 food filters (M/CM+IR) 2 coloured indirect filters (red + blue) 86 / Chapter 3
colour sequences possible via LED RGB combined with EMOTION touch panel or other DALI-controlled systems colour sequences possible via LED RGB, as indirect lighting components static colour situations possible via indirect colour filters in red and blue
www.zumtobel.com/productsites
One unit a variety of mounting options: cord pendant chain adapter direct installation on the ceiling Installation benefits: easy and simple installation, largely without tools luminaire prewired, no-tool electrical installation on plug-in terminal in place twist and lock mechanism makes closing luminaire easy
Models: indirect lighting optionally: 22 W T-R 5, LED-RGB direct lighting optionally: 4257 W TC-TELI, 60250 W QT 32, 70150 W HIT, 85 W QL, 100 W HST
reflectors: plastic reflector (translucent or painted in titanium), prismatic reflector and metal reflector (also available in titanium-painted finish)
www.zumtobel.com/productsites
Chapter 3 / 87
Application: applications focus on industrial bays (processing industries, assembly and warehousing); also multifunction bays and sports halls alternative applications in many countries: large-area shop solutions, e.g. UK product range designed for various room heights (low, wide and very wide)
in principle, there are two approaches: either used as a replacement concept for high-bay reflector luminaires (e.g. COPA I biggest size) or as a new installation
88 / Chapter 3
www.zumtobel.com/productsites
Benefits: higher ambient temperatures, 35 C or more (depending on version) significantly better lighting quality excellent colour rendering index (Ra > 80), especially compared with high-intensity discharge lamps no warm-up and restrike times straightforward integration of emergency lighting (centrally powered and local battery solutions) dimming is easily possible: connection to presence detectors and daylight sensors = greater individuality immediate energy savings
long maintenance intervals, especially when combined with industrial ballasts and long-life lamps luminaire can be separately switched even with different light colours failure of one light source does not affect other light sources virtually constant luminous flux in case of fluorescent lamps compared with rapid drop in luminous flux in case of high-pressure light sources adjustable lighting technology
9 10 11 12 13 14 15
6 Initial E
9 10 11 12 13 14 15 Maintenance E
Subsequent E
www.zumtobel.com/productsites
Chapter 3 / 89
PERLUCE louvre first closed surface-mounted louvre luminaire available on the market optional colour accents excellent light output ratio suitable for high visual requirements maintenance factor better than in open louvre luminaires smooth surfaces, easy to clean lamp and louvre protected against soiling Design by Studio Ambrozus
90 / Chapter 3
www.zumtobel.com/productsites
Application: louvre: for high visual requirements in rooms where dust and dirt are present, e. g. workshops, laboratories, kitchens, classrooms and nursery schools
opal: circulation areas, staircases, waiting rooms, wellness areas, changing rooms, nursery schools and canteens
Lighting technology: T16 technology with electronic ballast louvre: Bivergence plus darklight louvre, reduced luminance levels of L < 1000 cd/m2 at 65, UGR < 19 or < 16 acc. to EN 12464; ceiling brightened up by laterally perforated upper reflector opal: opal optic, UGR < 22 or < 25 acc. to EN 12464
Quality: 1-lamp and 2-lamp models in same housing excellent light output ratio and homogeneous illumination of luminaire injection-moulded optic (generally thin luminaire walls) high stability of optic end-to-end installation without gaps luminaries can be opened easily, even when mounted end to end
Models:
PERLUCE linear PERLUCE wallwasher PERLUCE square opal/louvre opal 1/14 W T16 (IP50) 1/35 W T16 (IP54) 2/18 W TC-L (IP50/54) 1/24 W T16 (IP50) 1/49 W T16 (IP54) 4/14 W TC-L (IP50/54) 1/28 W T16 (IP50) 1/35 W T16 (IP50/54) 1/80 W T16 (IP54) 1/49 W T16 (IP50/54) 1/54 W T16 (IP50/54) 2/35 W T16 (IP54) 1/80 W T16 (IP50/54) 2/49 W T16 (IP54) 2/14 W T16 (IP50) 2/28 W T16 (IP50) 2/35 W T16 (IP50) 2/49 W T16 (IP50/54) Protection type Protection type Protection type IP50 standard IP54 standard IP50 standard (IP54) (IP54)
www.zumtobel.com/productsites
Chapter 3 / 91
S C U B A
Benefits: unique, innovative design smooth/ergonomic surfaces language and catches high light output ratio thanks 15 slope of all visible surto calculated, optimised prisfaces (recommended for food matic structure industry) innovative sealing rim between optionally with heavy-duty electronic ballast for longer basic housing and diffuser service life at high ambient special CHEMO diffuser temperatures (combines benefits of PC and PMMA) Product range with PC, PMMA or CHEMO diffuser: T26 1-/2-lamp 18 W electr. ballast, low-loss ballast; 684 mm T26 1-/2-lamp 36 W electr. ballast, low-loss ballast; 1,294 mm T26 1-/2-lamp 58 W electr. ballast, low-loss ballast; 1,594 mm T16 1-/2-lamp 28/35/49 W; 1,294 mm/1,594 mm T16 1-lamp 54/80 W; 1,294 mm/1,594 mm Special designs (available upon request): SCII, hightemperature, low-temperature, 92 / Chapter 3 emergency lighting, heavyduty electronic ballast, plastic catches, halogen-free wiring
The Lighting Handbook
www.zumtobel.com/productsites
Properties of diffuser materials: Polycarbonate (PC) UV-stabilised extremely impact-resistant chemically resistant, to a limited extent Polymethylmethacrylate (PMMA) 100 % UV-resistant good chemical resistance impact absorbing UV-resistance
30 25 20 15 10
CHEMO extremely UV-resistant, comparable to PMMA substantial resistance to a large number of chemicals impact resistance similar to PC
Yellowness Index
5 0
60
80
100
120
Heavy-duty electronic ballasts The PC industry product range was specially designed for use in harsh industrial environments. All T16 and T26 models ensure a long service life, even under tough environmental conditions.
Comparison of service life of a PC industry ballast compared with a standard electronic ballast, taking the SCUBA luminaire as an example
Reliability
90 %
95 %
100 %
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
Standard electronic ballast 1/58 W, at 38 C max. 2/58 W, at 32 C max. 1/36 W, at 47 C max. 2/36 W, at 35 C max.
Measured values refer to ambient temperature, without through-wiring. Subtract 7 C in case of through-wiring.
www.zumtobel.com/productsites
Chapter 3 / 93
All luminaires boast a highquality surface finish resistant to cleaning agents and Application: In healthcare settings operating theatres laboratories air locks intensive care units emergency wards examination and treatment rooms recovery rooms hallway and corridor areas administrative areas laundries and kitchens doctors surgeries healthcare and rehabilitation centres
disinfectants, and have been given the ENEC mark for their rugged, durable design.
In industry and engineering electronics electrical engineering micromechanics biogenetics pharmaceutical and chemical companies laboratory technology genetic engineering food technology extremely critical areas of food production food industry hallway and corridor areas laundries and large-scale catering establishments
94 / Chapter 3
www.zumtobel.com/productsites
CLEAN Supreme IPA certificate for clean-room compatibility in clean-rooms in Classes 3 to 9 (ISO), issued by the Fraunhofer Institute antistatic surface finish frameless, continuous glass diffuser trouble-free operation in rooms with positive and negative pressure containment systems thanks to special valve system easy installation of luminaires, convenient relamping CLEAN Advanced IPA certificate for clean-room compatibility in clean-rooms in Classes 3 to 9 (ISO), issued by the Fraunhofer Institute cover made of anodised aluminium models with toughened safety glass or shatter-proof PMMA acrylic glass trouble-free operation in rooms with positive and negative pressure containment systems thanks to special valve system extremely resistant materials easy installation of luminaires, and high-quality workmanconvenient relamping ship CLEAN Classic cover made of anodised aluminium model with PMMA acrylic glass extremely resistant materials and high-quality workmanship
www.zumtobel.com/productsites
Chapter 3 / 95
ZBOX Plug & Play Lighting control system for hotels, private dwellings and shops
Plug & Play pre-addressed and pre-programmed for hotel rooms plug-in connections locally as stand-alone system, or networked with LUXMATE bus web tool for fine adjustment no licence, no special skills required, no experts needed direct connection via Ethernet (TCP/IP) transparency of costs from design through to operation can be upgraded using standard LUXMATE bus components 4 control points included no addressing of luminaires, except for RGBW (DALI Broadcast) Intuitive: clear design layout and functions of control units self-explanatory symbols Emotion: lighting scenes dynamism and controlled colour changes
ZBOX-Cxx: W: 86 mm H: 86 mm D: 11 mm
control concept completely focused on guest ZBOX does what guests expect day and night scenes (networked with LUXMATE add-on module: radio-controlled clock)
96 / Chapter 3
www.zumtobel.com/productsites
Safety: emergency lighting can be dimmer with autoprotect integrated facility (overload protection crash channel provides light for lighting loads) if controller fails quick and easy replacement, no special skills required
Main functions: scenes and individual adjustment special control concept functions adjustable via ZBOX.WEBTOOL mains cut-off device backup function with SD card (under development) ZBOX.NIGHTLOGIC day/night scenes (various scenes are called up depending on the time of day)
Pros: energy savings through lighting scenes at reduced lighting levels cost savings operating costs dimming increases service life of incandescent lamps longer maintenance cycles cost savings fast thanks to pre-addressing and plug-in connectors do it yourself using the ZBOX.WEBTOOL package optimised for workflow on site
Technical data: 8 x output (300 W) switchable via relay dimmable via DALI Broadcast (all electronic ballasts connected are dimmed simultaneously; no DALI addressing; max. of 10 DALI loads) slot for 300 VA universal dimmer (20300 VA; 0 ... 100 %) 1 x output (300 W) for RGBW control of wellness luminaire (DALI group numbers 1 4; max. 16 DALI loads) 1 x output for 1 blinds/ curtain motor 230 V-AC Energy dissipation: 10 W in operation (without dimmer) 4.5 W standby 0.7 W per dimmer
5 x input for DALI ZBOX Circle control unit multiple allocation (e.g. 1 x left bed + 1 x right bed + 2 x room + 2 x bathroom + 2 x hall) 2 x input Key Card and Aux 230 V-AC, potentialfree 1 x LUXMATE bus connection (1 bus load) 1 x RJ45 Ethernet LAN connection for web tool and service
www.zumtobel.com/productsites
Chapter 3 / 97
ONLITE escape sign and emergency luminaires Combining design and functionality
All ONLITE escape sign luminaires are based on first-class lighting technology. This ensures that pictograms are uniformly illuminated at a minimum luminance level of 200 cd/m2. Each ONLITE escape sign can be supplied via three different systems. The respective type of supply is indicated by the luminaires name: NT 1/3 Separate battery supply with auto test and control test function (1 and 3 h stand-alone time) An attractive design and the use of high-quality materials guarantee not only maximum functionality and reliability, but also pleasant, unobtrusive integration with the interior design. NSI Supplied via LPS system (communication via Power Line) DALI Supplied via CPS system (communication via DALI)
230 V AC
NT 1/3 auto test no DALI bus connected fixed test cycle programmes are run automatically, displayed via bicoloured LED low installation effort
230 V AC
SB 128 Controller
98 / Chapter 3
www.zumtobel.com/productsites
NT 1/3 control test DALI bus connected: luminaires centrally monitored individual configuration/ monitoring of luminaires minimum testing effort fully automatic test log book max. functional reliability
NSI supply via LPS Communication with luminaires with PLC (power line control) via supply line. All luminaires can be individually controlled and monitored. maximum intrinsic safety thanks to self-contained systems easy maintenance low installation effort reduced fire load can be fully integrated into lighting management system
DALI supplied via CPS Supply via CPS, diesel generator or 2nd mains. Monitored via DALI interface. every DALI luminaire can be used as an emergency luminaire minimum maintenance effort interference-free data communication no installation of additional monitoring modules in luminaires required security function of final circuit (makes sure that luminaires can be switched on reliably if communication line is defective)
www.zumtobel.com/productsites
Chapter 3 / 99
ONLITE RESCLITE A world champion in terms of lighting technology and energy efficiency
With a Power LED and three sophisticated optics, RESCLITE paves the way to a new era of emergency lighting. Ideal light distribution thanks to optimum illumination. Only a very small number of luminaires are required for emergency lighting in conformity with relevant standards. Minimum energy consumption and maximum installed load of 5 W. Power input in non-maintained mode approx. 1.5 W. This means that only very small-scale supply and cable systems are needed. Mounting options Recessed into ceiling Minimum design effort. Completely independent from general lighting. The only design work needed is the placing of spacing tables. Extremely easy to install and maintain. Standard installation terminals for throughwiring up to 2.5 mm. Strain relief devices and covers fixed without tools ensure quick, straightforward installation.
Surface-mounted on ceiling
100 / Chapter 3
www.zumtobel.com/productsites
RESCLITE escape LED emergency luminaire for escape route lighting according to EN 1838
Max. spacing (m) wall/luminaire b1 a1 5.9 5.7 6.4 6.1 7.1 6.7 8.1 7.4 7.5 2.3
Max. spacing (m) luminaire/luminaire a2 b2 13.4 12.9 14.6 14.0 16.4 15.7 19.5 18.5 22.0 19.9
a2 b2
a1 b1
a Emergency power supply via separate battery for 1 hour (NT1) and central battery (NSI, DALI) b Emergency power supply via separate battery for 3 hours (NT3)
width of escape route: 2 m minimum illuminance across width 1 m: 1 lx uniformity higher than 40 : 1 maintenance factor considered: 0.8
www.zumtobel.com/productsites
Chapter 3 / 101
RESCLITE anti-panic LED emergency luminaire for anti-panic lighting according to EN 1838
Max. spacing (m) wall/luminaire a1 b1 3.4 3.1 3.5 3.1 3.2 2.6 1.5 0.9 0.9 0.7
Max. spacing (m) luminaire/luminaire a2 b2 9.3 8.9 10.1 9.5 11.1 10.5 12.9 11.6 12.4 10.4
rotationally symmetrical distribution minimum illuminance: 0.5 lx uniformity higher than 40 : 1 maintenance factor considered: 0.8
h a2 b2 a1 b1
a1 b1
a2 b2
a2 b2
a1 b1
a Emergency power supply via separate battery for 1 hour (NT1) and via central battery (NSI, DALI) b Emergency power supply via separate battery for 3 hours (NT3)
102 / Chapter 3
www.zumtobel.com/productsites
RESCLITE spot LED emergency luminaire for increased illuminance levels acc. to EN 1838
rotationally symmetrical distri- reflection factors: 0 bution complies with glare reduc minimum illuminance: 5 lx tion acc. to EN 1838 maintenance factor considered: 0.8
a, b
a, b
a Emergency power supply via separate battery for 1 hour (NT1) and via central battery (NSI, DALI) b Emergency power supply via separate battery for 3 hours (NT3)
www.zumtobel.com/productsites
Chapter 3 / 103
Type
Light Protection Protection Recognition Surface- Pendant- Cord Wallmounted source type class range on ceiling mounted suspension mounted 90 wallmounted Recessed TECTON
104 / Chapter 3
RESCLITE
LED
IP40
cV s
ARTSIGN
LED
IP20
cs
15 m 3)
cs
15 m 3) 7.6 m 5)
www.zumtobel.com/productsites
IP65 1)
cs
20 m 3)
COMSIGN
cs
28 m 3) 15 m 4)
COMSIGN II LED
IP20
cs
28 m 3) 15 m 4)
PURESIGN LED
IP40
cs
30 m 3) 15 m 4)
ECOSIGN
32 m s 16 wc m 4)
2)
www.zumtobel.com/productsites
2) 1) with cable feed only 2) reduced to IP40 3) acc. to EN 1838 and DIN 4844 2) 4) lt. VkF and SN EN 1838 (model for CH) 5) narrow side if mounted on the ceiling
3)
ECOSIGN safety
s wc
Chapter 3 / 105
cs
90 m 3) 45 m 4)
Chapter 4
Service life
Light colour
Colour rendition
Lamp characteristics
Operating position
Lamp power
Warm-up time
Re-start time
Dimming capability
2 / Chapter 4
Lamp characteristics
1. Power The electrical power consumption of the lamp as opposed to the power consumption of a system comprising lamp and ballast. 2. Luminous flux/luminous efficiency The luminous flux specifies the total amount of light generated by a lamp. The rated luminous flux is measured at a standardised measurement temperature of 25 C in units of lumen [lm]. The ratio of luminous flux to electrical power consumption gives the luminous efficiency [lm/W]. The system light output also takes the ballasts losses into account. 3. Service life The average service life is normally specified, being the time by which statistically half the lamps are still working (mortality), or half the lamps have failed. This test is subject to standardised operating conditions. Lamp manufacturers display this failure rate by curves. In Chapter 8, they are shown as maintenance factors (LSF). 4. Drop in luminous flux The initial luminous flux of a new lamp decreases over its time of operation (lumen maintenance), due to the ageing of its chemical and physical components. Lamp manufacturers display this drop in luminous flux by curves. In Chapter 8, they are shown as maintenance factors (LLWF). 5. Light colour The light colour describes the colour impression made by a white light source as relatively warm (ww = warm) or relatively cool (nw = intermediate, tw = cool). It is affected by the red and blue colour components in the spectrum. 6. Colour rendition The spectral components of the light determine how well various object colours can be reproduced. The higher the colour rendition index (Ra or CRI), or the lower the colour rendition group number, the better the colour rendition in comparison with the optimum reference light.
Chapter 4 / 3
7. Warm-up time Discharge lamps in particular need between 30 seconds and several minutes to warm up and output the full luminous flux. 8. Re-start High-pressure discharge lamps need to cool down for several minutes before they can be started again. 9. Dimming capability Besides incandescent and halogen incandescent lamps, nowadays all fluorescent and compact fluorescent lamps can also be dimmed over almost any range. Metal halide lamps, however, are still not approved by the manufacturers for dimming, because this may have uncontrollable effects on light quality and lamp service life. The new series of special models for indoor and outdoor applications constitute an exception. The power of highpressure sodium- and mercury-vapour lamps can be varied, but only in discrete levels. 10. Operating position Manufacturers specify the permitted operating positions for their lamps. For some metal halide lamps, only certain operating positions are allowed so as to avoid unstable operating states. Compact fluorescent lamps may usually be used in any operating position; however, important properties such as the luminous flux vs. temperature curve may vary with the position.
4 / Chapter 4
QR-CBC
QT12
QR111
H a l o ge n
l a m ps
QT32
QT-DE
QPAR51
QPAR64
Halogen lamps for mains and low-voltage operation longer service life and higher luminous efficiency than incandescent lamps easy to dim
brilliant light excellent colour rendition applications: retail and domestic areas, restaurants and catering
How they work Current flows through a filament and heats it up, just as in incandescent lamps. These lamps therefore generate a relatively large amount of heat. The halogen cycle increases the efficiency and extends the service life compared with traditional incandescent lamps. Low-voltage types are very small and are ideal for precise direction of light, but do require a transformer.
The Lighting Handbook
Due to European legislation, only the most energy-efficient versions of this lamp group will be permitted in future.
Chapter 4 / 5
l a m ps
T16/T26
T16-R
T16-R
F l uo re s c e n t
Fluorescent lamps high to very high luminous efficiency (in particular T16 HE) good to excellent colour rendition
long service life extensive range of types dimmable application: economically efficient widearea lighting
How they work An alternating electric field generates invisible UV radiation between the two electrodes in the discharge tube. This radiation is converted into high-quality visible light in the fluorescent material. The lamps need a starting aid and a current limiting device, usually combined in an electronic ballast. The luminous flux is highly dependent on the ambient temperature.
f l u o re s c e n t
l a m p s
TC-DEL
TC-TEL(I)
TC-TEL(I)
TC-L
C o m p a c t
Compact fluorescent lamps compact designs high luminous efficiency excellent colour rendition
extensive range of types dimmable applications: commercial and high-profile interiors, restaurants and catering
The Lighting Handbook
How they work These lamps are compact versions of the linear or circular fluorescent lamps, and operate in a very similar way. The luminous flux is dependent on the operating position and temperature. 6 / Chapter 4
lamps
HIT-TC-CE
HIT-CE
HIT-DE-CE
HIT-DE
HIE
HIT
Metal
Metal halide lamps high luminous efficiency good to excellent colour rendition high colour stability for ceramic discharge-tube lamps
halide
How they work In metal halide lamps, a highly compact electric arc is produced in a discharge tube. The composition of the materials in the tube determines the light quality. A starter is needed to switch on the lamp, and the current must be limited by a ballast. Practical electronic ballasts are also available for low-power lamps.
Chapter 4 / 7
va po ur
Sodium vapour lamps high luminous efficiency and long service life satisfactory to poor colour rendition can be dimmed in discrete steps applications: industrial bays, street lighting
HST-CRI HSE HST
l a m ps S o di um
How they work The discharge in the linearly extended ceramic discharge tube is defined by sodium, so the light is yellowish and only suitable for special applications. The colour-improved SDW lamp by Philips is a popular choice for lighting retail areas. A starter is usually needed to switch on the lamp, and the current must be limited by a ballast. Mercury vapour lamps no starter, just ballast required satisfactory to poor colour rendition can be dimmed in discrete steps applications: industrial bays, street lighting
HME
How they work The high-pressure mercury vapour lamp is actually the forerunner to the modern metal halide lamp, although it provides a far poorer light quality. The lamps can be started at mains voltage, and so only need a ballast for current limiting. In line with European legislation, these lamps will be banned from the market from 2015 (efficiency too low).
The Lighting Handbook
8 / Chapter 4
LMG-IHf
I nduc t i o n
QL by Philips only 55 W, 85 W and 165 W excellent colour rendition very long service life rotationally symmetrical light distribution
applications: areas where it is difficult to replace lamps; commercial and industrial interiors, retail, indoor and outdoor public areas
l a m ps
How they work A high-frequency electromagnetic field is coupled into the glass bulb via an antenna protruding into the bulb. This produces UV radiation which is then converted into visible light by fluorescent material, just as in fluorescent lamps. The amalgam technology used in these lamps makes their luminous flux only very slightly temperature-dependent. The lamps can only be operated using special electronic ballasts by Philips. Systems have a very long service life because the only parts subject to wear are in these ballasts. As yet there are no dimmable electronic ballasts available.
Chapter 4 / 9
e m i t t i ng
di o de s
Light emitting diodes (LEDs) very efficient light production extensive model series can be switched and dimmed as required extremely long service life good to very good colour rendering
applications: LEDs can be used for functional and decorative lighting, both indoors and outdoors
( L EDs ) L i ght
How they work Light emitting diodes are modern semiconductor devices. Their properties are determined by the materials used as well as the mechanical design. The active semiconductor layer, in which radiation is produced, is sandwiched between a positive and a negative substrate. Depending on the materials used, a large variety of different colours are produced directly. White light can only be produced using fluorescent materials from blue LEDs or by mixing RGB. Today, the smallest chips have a side length of approx. 250 m (1 micrometre = 1 one-thousandth of a millimetre). The LED modules are supplied with power via appropriate constant current or constant voltage converters. They can be dimmed easily. The LEDs very long service life of several 10,000 hours can only be achieved when overheating is avoided (thermal management). Today, LEDs already count among the most efficient light sources for general lighting.
10 / Chapter 4
20
20
40
60
80 C
Ambient temperature
Chapter 4 / 11
2. CSO Cool Spot Optimizer The photometric data of luminaires typically apply to a standard temperature of 25 C. Where a different ambient temperature prevails, the lamps luminous flux is also affected. In fluorescent lamps, the luminous flux declines in particular at lower temperatures. In order to increase the efficiency of luminaires fitted with T16 lamps, the so-called Cool Spot Optimizer (CSO) may be used. The CSO effects a temperature increase at the lamp by approx. 10 to 20 degrees, resulting in a corresponding shift to the left of the T16 curve displayed (page 11).
LB approx. 60 % LB approx. 90 %
In the above example, the luminous flux produced is therefore increased by 50 % and the number of luminaires required is reduced by one third, owing to the CSO. For lighting design purposes, an appropriately adjusted planned luminous flux has to be calculated. The CSO may only be used in conventional T16 28/54 W and/or 35/49/80 W lamps using cold-spot technology, and must be fitted at the lamp end (see picture).
12 / Chapter 4
3. Ageing/burning in Brand new lamps stabilise during the ageing phase. This is the period immediately after the lamps are switched on for the first time, when the initially encapsulated mercury is vaporised and evenly distributed in the lamp. To ensure perfect operation, one should allow a period of 2 to 4 days of operation without dimming or switching, particularly in dimming installations. Unstabilised lamps may differ in brightness and light colour, even exhibiting flickering at low dimming levels. This may have a negative impact on the lamp service life. Also, before assessing a lighting installations illuminance level and lighting quality using already aged lamps, these should be burnt in over a minimum period of 3060 minutes without dimming or switching them. 4. Lamp orientation Owing to the two electrodes (tube ends) not being identical in design, it matters how one or more T16 fluorescent lamps are fitted in the luminaires. In general, lamp ends should always have the same orientation i.e. in multi-lamp luminaires they should lie next to each other, and where lamps are positioned vertically, they should preferably also be at the bottom. For cool environments, it may make sense depending on the type of luminaire to arrange the lamp/s differently.
multi-lamp
Chapter 4 / 13
Further details for TETRIS and continuous row arrangements: Particular attention is needed for special lamp arrangements like in TETRIS (TECTON or SLOT luminaires) or in continous-row lighting systems. The so-called TETRIS arrangement provides for lamps overlapping several centimetres. This enables to compensate for the dark zone at the lamps ends. In order to provide for maximum uniformity, it is recommended to also align all lamps identically. The last lamp/s, however, should be turned so as to make the lamp end head towards the centre of the luminaire.
single-lamp
twin-lamp
In a continous-row lighting system, the maximum total luminous flux will be achieved if the lamp ends are placed next to each other, if possible. For cool environments, here too it may make sense to arrange the lamp/s differently.
Example of interior lighting using T16 and T26 Room dimensions: length = 8 m, width = 6 m, height = 3 m Reflection factors: ceiling = 70 %, walls = 50 %, floor = 20 % Required maintenance value of illuminance: 500 lx Option 1: SPHEROS ind/direct luminaire, matt louvre, 2/36 W electr. ballast Option 2: SPHEROS ind/direct luminaire, matt louvre, 2/28 W electr. ballast
Option 1 2/36 W Number of luminaires 8 Max. lamp luminous efficiency 93 lm/W Power consumption per m2 per 100 lx 2.2 W/m2/100 lx Luminaire efficiency 85 % Utilization factor 66 % Energy saving Option 2 2/28 W 8 104 lm/W 2.0 W/m2/100 lx 91 % 73 % 10 %
Chapter 4 / 15
16 / Chapter 4
2. Lamp orientation The luminous flux of compact fluorescent lamps is highly dependent on their operating position. Luminaire efficiency can be maximised by fitting the lamps properly in the luminaires. Standard types have a cool spot in the exposed lamp bend, so that self-heating and convection may lead to a temperature rise here. In amalgam lamps, the cool spot lies in the lamp base. In compact luminaires with horizontal lamp arrangement (e.g. downlights), it is therefore recommended to fit the lamps with electrodes uppermost wherever possible. As the marking of lamps does not allow for standard identification of the electrodes position, the lamp is fitted with that side facing upwards where adjacent tubes are not connected with each other - these are the two tube ends with the electrodes inside.
Chapter 4 / 17
18 / Chapter 4
HQI-E/P HQI-T HCI-E HCI-E HCI-T HCI-T HCI-TM HCI-TM POWERBALL POWERBALL POWERBALL POWERBALL POWERBALL POWERBALL 250 W/D 250 W/D 250 W/D 250 W/WDL 250 W/NDL 250 W/WDL 250 W/NDL 250 W/WDL 250 W/NDL
Tube E 40 any no 12,000 h 12,000 h 12,000 h Tube E40 any no Tube G 22 any no Tube G22 any no
OSRAM HQI-E
Design Base Operating position Approved for operation in uncovered luminaires Average service life Reduction in lumin., flux 26,000 lm 3,000 K 92 25,000 lm 4,200 K 98 26,000 lm 3,000 K 92 25,000 lm 4,200 K 98
Ellipsoid E 40 any no
Tube E 40 any no
Ellipsoid E 40 any no
12,000 h 12,000 h 12,000 h 12,000 h 12,000 h 12,000 h See maintenance factors in Chapter 8 Calculation of economic efficiency
Operation with high-pressure sodium-vapour lamp ballast (HS) Luminous flux 19,000 lm 17,000 lm 20,000 lm 24,500 lm Colour temperature 5,200 K 5,200 K 5,200 K 3,000 K Colour rendition 90 90 90 91 index Ra
22,500 lm 4,200 K 95
Chapter 4 / 19
These Osram lamps must generally not be operated with a ballast for metal halide (HI) lamps. All data subject to change. For reliable information and data on other lamp types, please refer to the manufacturers data.
HQI-E
HQI-E/P
HQI-BT
20 / Chapter 4
HCI-TM POWERBALL 400 W/WDL HCI-TM POWERBALL 400 W/NDL
34,000 lm 4,000 K >60 42,000 lm 3,500 K >65 not permitted not permitted 41,000 lm 3,000 K 94 40,000 lm 4,200 K 95
400 W/D
400 W/D
400 W/D
Design Base Operating position Approved for operation in uncovered luminaires Average service life Reduction in lumin., flux
12,000 h 12,000 h 12,000 h 12,000 h 12,000 h See maintenance factors in Chapter 8 Calculation of economic efficiency
27,000 lm 5,900 K 90
Operation with metal-halide lamp ballast (HI) Luminous flux 26,000 lm 25,000 lm 34,000 lm Colour temperature 5,500 K 5,200 K 4,400 K Colour rendition index Ra 90 90 60 Operation with high-pressure sodium-vapour lamp ballast (HS) Luminous flux 34,000 lm 31,000 lm 40,000 lm Colour temperature 5,300 K 4,700 K 3,800 K Colour rendition index Ra 90 90 65
35,000 lm 5,200 K 90
All data subject to change. For reliable information and data on other lamp types, please refer to the manufacturers data.
Design Base Operating position Approved for operation in uncovered luminaires Average service life Reduction in lumin., flux 30,000 lm 4,300 K 70 35,000 lm 3,800 K 70 32,500 lm 4,500 K/6,700 K 70 42,500 lm 4,000 K/5,400 K 70
Ellipsoid E 40 pendant 15 no
Tube E 40 pendant 20 no
20,000 h 20,000 h 20,000 h 20,000 h 20,000 h See maintenance factors in Chapter 8 Calculation of economic efficiency
Operation with metal-halide lamp ballast (HI) Luminous flux 18,000 lm 18,000 lm 20,500 lm 4,500 K/6,700 K 4,500 K/6,700 K 4,500 K Colour temperature Colour rendition index Ra 70 70 65 Operation with high-pressure sodium-vapour lamp ballast (HS) Luminous flux 25,500 lm 25,500 lm 25,000 lm 4,000 K/5,400 K 4,000 K/5,400 K 4,000 K Colour temperature Colour rendition index Ra 70 70 65
Chapter 4 / 21
All data subject to change. For reliable information and data on other lamp types, please refer to the manufacturers data.
LBS code
System power
Osram
Fluorescent and compact fluorescent lamps T16 /840 Fluorescent lamp 16 mm light colour 840 Starcoat T5 F/T5/840 ------T5 Circline --T5 Luxline Plus FHE/840, FHO/840 ---
1480 W
Lamp descriptions acc. to LBS (ZVEI) a comparison of models and manufacturers descriptions
22 / Chapter 4
MASTER TL5 HE/HO Super 80/840 MASTER TL5 HO/VHO TOP /830 TL5 HO Coloured Pro MASTER TL5C T8 Polylux XLR F /830 --Electronic Biax Biax S - 2 pin Biax D/E - 4 Pin Biax T/E - 4 Pin Biax L - 4 pin --T8 Luxline Plus F /830 --Mini-Lynx T /E27 Lynx-S Lynx-DE Lynx-TE Lynx-LE --MASTER PL-C 4 Pin MASTER PL-T TOP 4 Pin MASTER PL-L 4 Pin ---
T16-I /830
24120 W
T16-bu
Fluorescent lamp 16 mm amalgam techn. light colour 830 Fluorescent lamp 16 mm blue
1480 W
T16-R(I)
2260 W
T26 /830
Fluorescent lamp 16 mm circular (partly amalgam techn.) Fluorescent lamp 26 mm light colour 830
1558 W
L /830
T26-LL
1558 W
TC-TSE
530 W
TC-S
511 W
MASTER TL-D Super 80 /830 --MASTER TL-D Xtra/Xtreme DULUX EL E27 MASTER PL Electronic DULUX S MASTER PL-S 2 Pin
TC-DEL
1026 W
DULUX D/E
TC-TELI
1370 W
DULUX T/E IN
TC-L
1680 W
DULUX L (HE)
TC-LI
Compact fluorescent lamp (3 double tubes) with integral electr. ballast E27" screw-in cap Compact fluorescent lamp (1 short double tube) only for conventional/low-loss ballast Compact fluorescent lamp (2 double tubes) G24q 4-pin cap for conv./low-loss/electr. ballasts Compact fluorescent lamp (3 double tubes) amalgam techn. GX24q 4-pin cap Compact fluorescent lamp (1 long double tube) 2G11 4-pin cap or 2GX11 Compact fluorescent lamp (1 long double tube) 42G11 4-pin cap amalgam techn.
4080 W
DULUX L CONSTANT
LBS code
MASTER QL --A1/CL/E27 R80/E27 PAR38/E27 Q MR16 HI-SPOT ES 50 DLX-T Tube Satin Halogenstab Halogen Axial Normal E27 klar Refl. R80 PAR38 ---------
--ENDURA
Standard A55 CL Reflector NR80 PAR38 PAR38 HALOPAR 16 GU10 Twistline Pro Alu
HALOLUX CERAM
HALOSTAR
Lamp descriptions acc. to LBS (ZVEI) a comparison of models and manufacturers descriptions
DECOSTAR
Induction lamps LMG-IHf Ball-shaped induction lamp 55165 W LMG-SIHf Double-tube induction lamp 70150 W Incandescent and halogen incandescent lamps Incandescent GLS lamp 60 mm transp. 1575 W A60 /c R80 Incandescent reflector lamp 80 mm 40100 W PAR38 Parabolic incandescent reflector lamp 60120 W 38/8" = approx. 122 mm QPAR51 /GU10 Halogen incandescent lamp for mains 3550 W voltage, with parabolic aluminium reflector 51 mm GU10 cap QT32 /m Halogen incandescent lamp for mains volt., 60250 W tube-shaped 32 mm frosted outside QT-DE12 Halogen incandescent lamp for mains 602000 W voltage, cap at both sides 12 mm QT12-ax-LP LV halogen incandescent lamp approx. 20100 W 12 mm axial filament low-pressure system Low-pressure 12 V QR-CBC51 LV halogen incandescent lamp with 2065 W cold-light specular reflector 51 mm and glass cover QR111 /24 LV halogen incandescent lamp with 35100 W reflector 111 mm Radiation angle 24
Chapter 4 / 23
LBS code
HPL-N --MASTER Colour CDM-T SuperMini CMH/T, CMH/TC CMI-TC CMI-TD UVS Britelux HSI-SX/P --ConstantColor CMH /T/UVC CMI-T UVS Arcstream ARC/T HSI-T Kolorlux Standard HSL-BW
System power
Osram
HQL
Lamp descriptions acc. to LBS (ZVEI) a comparison of models and manufacturers descriptions
24 / Chapter 4
MASTER Colour CDM-Tm, CDM-TC, CDM-Elite-TC MASTER Colour CDM-TD MASTER HPI Plus BU-P ConstantColor CMH /TD/UVC ----MASTER SDW-TG MASTER SOX --SLP
HQI-T
High-pressure discharge lamps HME High-pressure mercury-vapour lamp 501000 W ellipsoidal HIT Metal halide lamp, tube-shaped, with 35150 W quartz discharge tube HIT-CE UVr Metal halide lamp, tube-shaped, with 35250 W ceramic discharge tube, reduced UV radiation HIT-TC-CE Metal halide lamp, tube-shaped, with 2070 W ceramic discharge tube, compact design
HCI-T
HIT-DE-CE
HCI-TS
HIE-P
HQI-E/P
---
Metal halide lamp, tube-shaped, cap at 35250 W both sides, with ceramic discharge tube Metal halide lamp, ellipsoidal, with quartz 70400 W discharge tube and anti-burst tube for open luminaires HST-CRI GX12 High-pressure sodium-vapour lamp, 50100 W tube-shaped, colour-improved, GX12 cap HST-MF High-pressure sodium-vapour lamp, 501000 W tube-shaped, increased luminous flux Low-pressure discharge lamps LST Low-pressure sodium-vapour lamp, 18180 W tube-shaped
SOX
Fluorescent lamps T 16 14 W T 16 21 W T 16 24 W T 16 28 W T 16 35 W T 16 39 W T 16 49 W T 16 54 W T 16 80 W T16-I 24 W T16-I 39 W T16-I 49 W T16-I 54 W T16-I 80 W T16-I 95 W T16-I 120 W T 16-R 22 W T 16-R(I) 40 W T 16-R(I) 55 W T 16-R(I) 60 W T 26 18 W T 26 36 W T 26 58 W 25 42 66 13,000 13,000 13,000 1618 24 27 3133 3941 46 54 61 approx. 88 27 46 54 61 approx. 88 approx. 105 approx. 130 26 4547 60 66 1920 36 5457
ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
1,200 1,900 1,750 2,600 3,300 3,100 4,300 4,450 6,150 1,950 3,400 4,750 4,850 6,800 7,300 9,200 1,800 3,200 4,000 5,000 1,350 3,350 5,200
2024,000 84 2024,000 87 2024,000 74 2024,000 93 2024,000 93 2024,000 76 2024,000 90 2024,000 81 2024,000 82 24,000 72 24,000 74 24,000 88 24,000 80 24,000 approx. 77 24,000 approx. 70 24,000 approx. 71 12,000 69 12,000 71 12,000 67 12,000 76 1620,000 68 1620,000 89 1620,000 93
Chapter 4 / 25
* Lamp service life = mean service life up to 50 % failure (exception: Philips QL up to 10 % failure)
26 / Chapter 4
System Lamp power service life* in W in h
15 17 23 31 17 23 31 8,000 8,000 8,000 8,000 8,000 8,000 8,000
Lamp name System power in W Lamp Max. system luservice life* minous efficiency in h in lm/W
25 30 42 8,000
Compact fluorescent lamps TC-D/-DEL 10 W ww, nw TC-D/-DEL 13 W ww, nw TC-D/-DEL 18 W ww, nw TC-D/-DEL 26 W ww, nw TC-T(I)/-TEL(I) 13 W ww, nw TC-T(I)/-TEL(I) 18 W ww, nw TC-T(I)/-TEL(I) 26 W ww, nw TC-TEL(I) 32 W ww, nw TC-TEL(I) 42 W ww, nw TC-TEL(I) 57 W ww, nw TC-TELI 60 W ww, nw TC-TELI 70 W ww, nw TC-TELI 85 W ww, nw TC-TELI/-QELI 120 W ww, nw TC-L 18 W ww, nw TC-L 24 W ww, nw TC-L 28 W ww, nw TC-L 36 W ww, nw TC-L 40 W ww, nw TC-L 55 W ww, nw TC-L 80 W ww, nw TC-LI 40 W ww, nw 8,000 8,000 12 14 1820 28 14 1820 28 3536 4647 62 65 75 92 128 19 2527 31 3439 45 5561 85 45 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 20,000 10,000 20,000 20,000 10,000 10,000 12.000 10,000 10,000 10,000 10,000 10,000 50 64 66 64 64 66 64 68 69 69 62 70 65 70 63 72 90 85 77 87 71 78
80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
G24d-1/q-1 G24d-1/q-1 G24d-2/q-2 G24d-3/q-3 GX24d-1/q-1 GX24d-2/q-2 GX24d-3/q-3 GX24q-3 GX24q-4 GX24q-5 2G8 GX24q-6 2G8 2G8 2G11 2G11 2GX11 2G11 2G11 2G11 2G11 2G11
600 900 1,200 1,800 900 1,200 1,800 2,400 3,200 4,300 4,000 5,200 6,000 9,000 1,200 1,800 2.750 2,900 3,500 4,800 6,000 3,500
* Lamp service life = mean service life up to 50 % failure (exception: Philips QL up to 10 % failure)
80 80
2G11 2G11
4.800 6.000
80 80 80
Compact fluorescent lamps TC-LI 55 W ww, nw TC-LI 80 W ww, nw Induction lamps LMG-IHf 55 W (QL 55 W) ww, nw LMG-IHf 85 W (QL 85 W) ww, nw LMG-IHf 165 W (QL 165 W) ww, nw Low-voltage halogen lamps QT 12 35 W ww QT 12 50 W ww QR-CBC 51 35 W (860) ww QR-CBC 51 50 W (860) ww QR 111 75 W (845) ww QR 111 100 W (845) ww High-voltage halogen lamps QT-DE 12 48 W ww QT-DE 12 80 W ww QT-DE 12 120 W ww QT-DE 12 160 W ww QT-DE 12 230 W ww QT-DE 12 400 W ww
90 90 90 90 90 90
90 90 90 90 90 90
Chapter 4 / 27
* Lamp service life = mean service life up to 50 % failure (exception: Philips QL up to 10 % failure)
28 / Chapter 4
System Lamp power service life* in W in h
8083 172 6,000 6,000
Lamp name System power in W Lamp Max. system luservice life* minous efficiency in h in lm/W
72 ca, 160 8083 172 ca, 24 4245 8083 4245 8083 172
912,000 912,000 6,000 6,000 7,5009,000 912,000 912,000 912,000 912,000 612,000 612,000
Metal halide lamps HIE 70 W HIE 100 W HIE 150 W HIE 250 W HIE 400 W HIE 1,000 W HIE-CE 70 W (Ceramic) HIE-CE 100 W (Ceramic) HIE-CE 150 W (Ceramic) HIE-CE 250 W (Ceramic) HIT 70 W HIT 150 W HIT 250 W HIT-TC-CE 20 W (Ceramic) HIT-TC-CE 35 W (Ceramic) HIT-TC-CE 70 W (Ceramic) HIT-CE 35 W (Ceramic)) HIT-CE 70 W (Ceramic) HIT-CE 150 W (Ceramic) HIT-CE 250 W (Ceramic) 63 72 74 93 93 90 83 71 84 91 69 77 76 71 83 91 83 83 83 96
ww, nw ww, nw ww, nw ww, nw, tw nw, tw nw ww, nw ww ww, nw ww ww, nw ww, nw nw, tw ww ww, nw ww, nw ww, nw ww, nw ww, nw ww, nw
80, 70 E27 4,9005,000 8296 6,000 80, 70 E27 7,3008,100 112115 6,000 80, 70 E27 10,50012,500 168177 6,000 90, 70, 60 E40 17,00025,500 275285 6,000 90, 70, 60 E40 20,50043,000 400460 6,000 60 E40 95,000 1,0501,065 6,000 90, 80 E27 5,0006,000 85 912,000 80 E27 8,0008,500 120 12,000 90, 80 E27 12,00013,500 170 912,000 80 E40 24,500 270 12,000 80 G12 5,2005,500 8296 6,000 80 G12 13,000 168177 6,000 90, 70, 60 E40 19,00021,000 275285 6,000 80 PGJ5/G8,5/GU6,5 1,6151,700 90, 80 PGJ5/G8,5 3,0003,500 4446 9,000 90, 80 G8,5 6,3007,300 8296 9,000 90, 80 G12 3,1003,500 4446 9,000 90, 80 G12 6,4007,300 8296 9,000 80 G12 14,000 168177 6,000 90, 80 E40/G22/G12 23,00025,800 272 612,000
* Lamp service life = mean service life up to 50 % failure (exception: Philips QL up to 10 % failure)
40 40
E40 E40
13,000 22,000
Metal halide lamps HIT-DE 70 W ww, nw HIT-DE 150 W ww, nw, tw HIT-DE 250 W ww, nw, tw HIT-DE-CE 35 W (Ceramic) ww HIT-DE-CE 70 W (Ceramic) ww, nw HIT-DE-CE 150 W (Ceramic) ww, nw HIT-DE-CE 250 W (Ceramic) ww High-pressure mercury vapour lamps HME 250 W ww, nw HME 400 W ww, nw High-pressure sodium vapour lamps HSE 250 W ww HSE 400 W ww HST-CRI 35 W (SDW-T) ww HST-CRI 50 W (SDW-T/-TG) ww HST-CRI 100 W (SDW-T/-TG) ww HST 250 W ww HST 400 W ww 275285 440450 4142 62 114116 275 440450 10,000 10,000 10,000 10,000 10,000 10,000 10,000 62 112 10,000 10,000
60, 20 E40 22,00032,000 60, 20 E40 36,00054,000 80 PG12-1 1,300 80 PG12-1/GX12-1 2,3002,400 80 PG12-1/GX12-1 4,9005,000 60, 20 E40 23,00033,000 60, 20 E40 37,00056,500
Chapter 4 / 29
* Lamp service life = mean service life up to 50 % failure (exception: Philips QL up to 10 % failure) For an extensive table of lamp data, please refer to the Technical Appendix of the ZUMTOBEL product catalogue. All data without engagement. In case of doubt, please contact the lamp manufacturer.
Since 21 May 2002, it has been prohibited to sell class D ballasts; class C ballasts have ceased to be produced since 21 November 2005 at the latest. With effect from 2017, magnetic ballasts with EEI = B1 and B2 as well as electronic ballasts = A3 will be prohibited for use with fluorescent lamps and highpressure discharge lamps. Example for T26 36 W 840: EEI A1 A2 A3 B1 B2 C D 19 W (25 % dimming is equivalent to 50 % A3) 36 38 41 43 45 45
30 / Chapter 4
ZUMTOBEL names
DOD
DALI
DALI only
DSI
110 V
Luminaires can be dimmed collectively No readdressing required when replacing control gear Luminaires can be dimmed collectively Can be used with some reservations in emergency lighting installations Long service life up to 100,000 h Ambient temperatures up to 70 C Integral over-/ undervoltage identification
Switchable at zero power Dimmability subsequently enabled Dimmability DALI-addressable Configurable Error and status feedback Dimming automatically blocked in DC mode Emergency lighting level adjustable for DC mode Emergency lighting-compatible DC mode Critical operating conditions
Special features
Addressability: Addressability: individual individual dimming dimming Flexible grouping Flexible grouping without rewiring without rewiring Luminaire status Luminaire status feedback feedback DSI control also possible
Chapter 4 / 31
For detailed information on ambient conditions and conditions of use, please refer to the product data sheets.
Long lamp service life High-quality light thanks to high-frequency operation More application options owing to DC operation Faulty lamps automatically switched off and switched on again after lamp replacement
Power consumption 20 to 88 %
558 W P C A 69 W 8W
Power consumption as a
55 W 45 W 35 W 25 W 8W
8W 1%
absent
increasing daylight
sufcient daylight
decreasing daylight
Set-DC 100 90 80 70 60 50 40 30 20 further potential saving of 27 % 10 0 59 53 48 43 39 35 30 28 AC-mode DC-mode potential energy saving of 52 % in (%)
32 / Chapter 4
absent
cloud cover
22
17
12
RGB and dimming of LED luminaires For dimming applications, owing to partly high outputs and accordingly possible interferences with electromagnetic compatibility, other points must be taken into account: A: control unit to LED C004 amplifier The cable between control unit and amplifier (LED C004) may be up to 20 m long. Make sure that the minimum input voltage of the amplifiers control input is at least 12 V. B: LED C004 amplifier to first LED luminaire
The Lighting Handbook
C: control unit to LED luminaire/luminaire group In order to avoid interferences with electromagnetic compatibility, the use of shielded cables for the lead between control unit and LED luminaires is recommended for cables longer than 0.5 m. Even if cables are shielded, cables longer than 15 m may lead to electromagnetic compatibility interferences in highly sensitive areas. Chapter 4 / 33
D: mains unit to LED luminaire/luminaire group The maximum cable length between mains unit and last
LED luminaire is specified in the table. Control gear should possibly be placed next to the luminaires.
A C + Ch 1-3 Control unit e.g. C002, K211 Ch 1 Ch 2 Ch 3 + Mains unit 12/24 V e.g. K240 + Uin + Ch 1-3 Uin Amplifier + Ch 1-3 e.g. LED C004 Ch 1 Ch 1 Ch 2 Ch 2 Ch 3 Ch 3 D B
LED luminaire
Cable length for supplying current-controlled LEDs, switchable Cable lengths are limited exclusively on the assumption that a maximum voltage drop of 0.7 V is permissible. In each case, they relate to the last luminaire in a group. It is assumed that the control gear operates at max. capacity for details, please refer to the control gears technical description. A minimum voltage of 4.5 V is assumed for each LED.
Please note: use copper cables. Cables must not be laid in parallel to mains/highvoltage conductors. Cable length for supplying current-controlled LEDs, dimmable PWM The max. cable length to a groups last luminaire may be 13 m. The cable cross-section has to be > 0.25 mm2. For cables longer than 1.5 m, shielded cables have to be used.
34 / Chapter 4
Cable cross-section/length 0.75 mm2 1 mm2 1.5 mm2 2.5 mm2 30.0 m 40.0 m 60.0 m 100.0 m 15.0 m 20.0 m 30.0 m 50.0 m
Mains
24 V-DC
SYSTEMLED Flood
Mains
24 V-DC PWM
* These luminaires must be additionally supplied with 24 V DC supply voltage! LEDOS 24 V SYSTEMLED Deco KAVA LED 24 V
DALI/DSI/switchDIM Mains
K210
24 V-DC
LED-mains unit
Mains
24 V-DC
SYSTEMLED Flood*
24 V-DC PWM
LED-mains unit Max. 3 POTI 100 K/Ohm linear or max. 3 x control voltage 010 V LEDOS 24 V SYSTEMLED Deco
C001
SYSTEMLED Flood*
KAVA LED 24 V
Chapter 4 / 35
Mains
24 V-DC PWM
DALI Mains
K211
24 V-DC
LED-mains unit
Mains
24 V-DC
Mains
24 V-DC
24 V-DC PWM
C002
Mains
24 V-DC
Application C004 PWM amplifier for controlling LED objects with higher output
LEDOS 24 V mono/RGB
LED-mains unit PWM control signal (e.g. C001, C002, C003, K210, K211)
C004
The C004 amplifier is used where the luminaire output is higher than the output power of the control unit used.
24 V-DC PWM
Colour sequence can be selected with DALI, 010 V KAVA LED RGB KAVA LED RGB
36 / Chapter 4
SYSTEMLED Deco RGB SYSTEMLED Deco RGB
24 V-DC PWM
C001
Mains
24 V-DC
LED-mains unit
24 V-DC PWM
DALI
C003
Mains
350 mA
LED-mains unit (constant current) ORILED 350 mA PANOS S 100 LED 350 mA On/Off Automatic colour sequence with sequencer, DALI 010 V Dimming
Mains
350 mA PWM
LEDOS B 350 mA
PWM control signal (e.g. C001, K210) ORILED 350 mA PANOS S 100 LED 350 mA
LEDOS B 350 mA
Mains
24 V-DC
LED-mains unit PWM control signal C350 PWM dimmer (e.g. C001, C002, C003, K211)
350 mA PWM
Mains
350 mA PWM
Dali
Chapter 4 / 37
Chapter 5
LUXMATE lighting management The intelligent control system for individual rooms and throughout buildings
Function Applications LUXMATE LITENET (based on TCP/IP and DALI) artificial light/daylight/blinds office building with high maximum flexibility owing to requirements in terms reconfiguration by software of flexibility, ergonomic com can be subsequently upgraded patibility and econ. efficiency with extra functions (on demand) OPC and BACnet interfaces with other building services and BMS optimised for TASK AREA concepts according to EN 12464 integration of ONLITE emergency lighting system customised control concepts LUXMATE PROFESSIONAL (based on LUXMATE bus system) artificial light/daylight/blinds conference rooms interfaces to media technology office buildings integration of ONLITE shopping malls emergency lighting system museums link to BMS and central industry maintenance LUXMATE EMOTION (based on DALI) presence-based/daylight-based control shops timer Health & Care special luminaires: RGB, Tempura wellness ACTIVE LIGHT lighting concepts control rooms flexibility of individual offices addressing/grouping in the home ZBOX (based on DALI) lighting scenes RGB colour control nightlogic Webtool
LITENET
ZBOX BASIC
EMOTION
2 / Chapter 5
LUXMATE DIMLITE (based on DSI/DALI/dimsave) daylight-based corridors, hallways infrared remote control unit small offices standard switch components commercial premises no addressing, group dimming classrooms zero-power switching and dimming
PROFESSIONAL
Lamps GLS lamps PAR lamps HV halogen incandescent lamps LV halogen incandescent lamps Fluorescent lamps LED
All control gear with DALI/DSI control input Phase dimmer: 50010005000 VA Phase dimmer: 50010005000 VA Phase dimmer: 50010005000 VA electronic dimmable transformer: 105 VA + 150 VA electronic dimmable ballast electronic dimmable LED converter 1 ch./3 ch.
Function 1 channel dimming, lighting scene, presence 2 channels dimming, daylight, presence 2 or 4-channel multifunction
Chapter 5 / 3
Control momentary-action switch, presence detector momentary-action switch, presence detector, light sensor momentary-action switch, Circle, light sensor, presence detector, IR remote control unit
Control units
Lamps
4 / Chapter 5
L N D1 D2 Fluorescent lamps T26/T16 TC-L/TC-DEL/TC-TEL dimsave DALI/DSI electronic ballast Fluorescent lamps T26/T16 TC-L/TC-DEL/TC-TEL L N DA-B DA-B
L N PE
**
DA DA
L N T T PIR Sc
DIMLITE single
or
L N D1 D2 DALI/DSI phase dimmer L' N
or
DALI/DSI transformer
L L N PE T D
D1 D2
Conventional presence detector phase dimmed phase * Light level can be stored NEW: snapsnap-on strain relief neutral and called up protective earth momentary-action switch input ** Alternative: If a single momentary-action switch is used, control line terminals T and T must be connecearth ted by a wire bridge. AC voltage LV halogen incandescent lamps max. 2 m
absolutely flicker-free, synchronous dimming easy programming and call-up of lighting scenes presence detector can be integrated, 3 functional profiles: ON, ON + OFF, CORRIDOR dimming range max. 1 % to 100 % (dimsave 10 %100 %)
can be operated by any standard momentary-action light switch several momentary-action switches can be connected in parallel DALI/DSI/dimsave auto identification (no mixed mode) easy installation designs available: installed in luminaire, recessed into ceiling (using strain relief supplied) or already built into luminaire
0%
50 %
Arguments for your customers dims the lighting from 1001 %, based exactly on the daylight available accurate window-light sensor rather than error-prone roomlight sensor energy savings of up to 75 % brightness level can be changed at any time using momentaryaction dimmer switches economically priced short pay-back period long lamp service life option to connect presence detector
The Lighting Handbook
Chapter 5 / 5
Built into luminaire Switch cabinet with LSD sensor with ED-EYE sensor
The Lighting Handbook
2 groups 4 groups
DIMLITE daylight
6 / Chapter 5
Control units
Lamps
L N PE
L N D1 D2
Daylight-based dimming
Conventional double momentary-action light switch On/off Dimming Fluorescent lamps T26/T16/TCL/TC-DEL/TC-TEL
GI
G II
L N T1 T2 PIR/Sc
DIMLITE daylight
S1 S2 G1 DA DA G2 DA DA
dimsave L N DA-B DA-B Group II (max. 25 control gear) DALI/DSI electronic ballast L N D1 D2
L N PE T D
phase neutral protective earth momentary-action switch input control line earth AC voltage
Chapter 5 / 7
absolutely flicker-free, synchronous dimming automatic daylight-based control alternatively: integration of one lighting scene or a presence detector possible presence detector with 3 functional profiles: ON, ON + OFF, CORRIDOR dimming range max. 1 % to 100 % (dimsave 10 %100 %)
can be operated by any standard momentary-action light switch several momentary-action switches can be connected in parallel DALI/DSI/dimsave auto identification (no mixed mode) easy installation designs available: installed in luminaire, recessed into ceiling (using strain relief supplied) or already built into luminaire
DIMLITE MULTIFUNCTION
Arguments for your customers compact lighting control unit for 2/4 luminaire groups switching possible between DALI/dimsave/DSI reducing stand-by loss: automatic power disconnection of lighting actuators via integrated relay up to 3 lighting scenes, one of them with daylight-based control (depending on additional devices) modular range of functions, to be individually combined: daylight-based control lighting scene module presence detectors/movement sensors group module infrared remote control unit CIRCLE comfort control unit AUTO setup: automatic initialisation, no addressing required Design notes DIMLITE multifunction 2ch two-channel unit and DIMLITE multifunction 4ch four-channel unit are identical except for the number of output channels and corresponding key inputs. Maximum cable length for all control lines (Control-IN, DSI and DALI): max. 300 m each at 1.5 mm. The DIMLITE outputs are DALI, dimsave or DSI broadcast no addressing is required during commissioning. Groups are assigned by wiring the lighting actuators accordingly. Maximum of 25 DALI units (25 DALI loads) or 50 DSI units per output channel. Only Zumtobel ED units may be connected to Control-IN. Maximum of 8 ED units at Control IN (exception: max. 1 light sensor). Up to 3 lighting scenes, depending on the control unit used; each control unit will always call up the same scene 1, 2, 3 or OFF. The functions of the ED-SDED2 ED unit may be selected using the integrated rotary switch: either scene module (1, 2, 3, OFF) or group module (dimming of Group 1, 2, 3, 4). Conventional 230 V momentary-action switches can be connected to the momentary-action switch inputs. PIR input to connect a conventional movement sensor. Relay for mains cut-off: 16 A resistive load; in case of higher loads or capacitive/inductive loads, an external power contactor is recommended.
8 / Chapter 5
DIMLITE
L 230 V AC N PE LED-Eye ED-Sens IRlight sensor (PD+IR) TOUCH Multi-sensor DALI/DSI HFG (1 DALI load) L N DA PCA DA DALI/DSI HFG (1 DALI load) L N DA PCA DA T26/T16 TC-L/TC-DEL/TC-TEL uorescent lamps T26/T16 TC-L/TC-DEL/TC-TEL uorescent lamps T26/T16 TC-L/TC-DEL/TC-TEL uorescent lamps T26/T16 TC-L/TC-DEL/TC-TEL uorescent lamps
Control units
Lamps
ED-SDED2 ED-SDED2 Circle Cxx control point group lighting scene module comf. contr. unit module
Relay DALI/DSI HFG (1 DALI load) L N DA PCA DA DALI/DSI HFG (1 DALI load) L N DA PCA DA TE one4all (1 DALI load) L N DA DA
Control IN
Presence detector
Chapter 5 / 9
Group 1
Group 2
Group 3
Group 4
Flicker-free dimming from 10 to 100 % Simple control using standard momentary-action switches or DIMLITE No commissioning or addressing DC-compatible, with xed 15 % dimming level Extremely low power consumption in standby mode Dimming curve matched to suit the way in which human eyes perceive brightness For all uorescent lamps and wattages
FAQ Can dimsave be used in EIB installations? The unit is controlled using DSI. We dont know of any EIB-DSI gateways. Is dimsave available as a multi-watt unit? No, only single-watt units are available for economic reasons. Control? By DSI signal. Can lamp faults be read out via the bus? No, there is no feedback channel. Cabling of dimsave? The same guidelines apply as for DALI installations. Mains power cabling, maximum length of control line: 300 m, at 1.5 mm. Recommended control of dimsave: a) switchDIM, i.e. momentary10 / Chapter 5
action standard switch for input; not more than 2 electronic ballasts shared by one momentary-action switch b) DIMLITE product range How are luminaires grouped in a dimsave installation? As usual with DIMLITE, via the cabling; each lighting group has its own control signal and control line. Can dimsave be used in emergency lighting installations? Yes. Only in installations without central monitoring. Please note: fixed DC dimming level of 15 %, cannot be changed. How can a faulty dimsave unit be replaced? Simply replace hardware; no commissioning or programming required.
Lamps
DA DA
DA DA
DALI-CSS DALI-CSW
L N PE DA
L DALI electronic ballast N PE PCA DA DA L DALI phase dimmer N PE DA APD DA L DALI transformer N PE DA TE DA * max. 64 DALI-compatible lamp control gear
Chapter 5 / 11
three lighting scenes can be called up using intuitive control unit two luminaire groups can be individually dimmed control of a max. of 64 DALI-controllable luminaires luminaires addressed via control unit
several control units can be used in parallel easy installation personal lighting scenes can be stored
ZBOX plug & play system for hotel rooms, private dwellings and shops
Plug & Play pre-addressed and preprogrammed plug-in connectors local stand-alone or networked system web tool for fine-adjustment, no licence required FAQs What is the minimum load to be applied to the universal dimmer? 20 W How many luminaires may be connected to a ZBOX Controller? Max. of 300 W/channel or 10 DALI loads; total maximum output power per ZBOX: 16 A. Depending on the outputs of the luminaires used, a varying number of electronic ballasts may be used for an automatic circuit-breaker! What happens at the output side during a short circuit? The dimming module has been fitted with overload protection for lighting loads, extremely high inductive or capacitive loads may destroy the dimmer. The relay contact and the Controller have no overload protection; the electrician must ensure proper selectivity of the installation. Does one always have to use a CIRCLE control unit? 12 / Chapter 5 direct connection via TCP-IP transparency of costs can be upgraded 4 control points included DALI Broadcast (no addressing of loads, except for RGB/W) Via the SDED2 input module, conventional momentaryaction switches can be integrated. How can the ZBOX be upgraded? All LUXMATE bus units can be connected to the ZBOX Controller. It is also possible to network several Controllers. In this case, the plug & play function may not work. It makes sense to let an engineer do the commissioning. Can the ZBOX also be used for other applications? For other applications such as nursing homes, private dwellings or patient rooms, the function and control concept can be adjusted via the ZBOX. WEBTOOL. Product options available? The ZBOX is available as a full version or as simplified version ZBOX easy. With ZBOX easy, no RGB colour control and motor control are possible.
Bathroom Mirror
Ceiling
Wellness**
Group 9 Blinds/curtain
(not ZBOX easy)
Group 8
Group 7
Ceiling Group 3
Entrance area
Ceiling
Group 5
Wall/table Group 4
optionally*
Group 6 * Every luminaire optionally connected to phase dimmer, DALI and/or relay
Chapter 5 / 13
L N COM T 1 T 2 COM T 3 DA DA DA DA DALI 1 DALI 2 MKXP installation box (please order separately) COM T 4
DA DA
DA DA Line 1: DALI control line e.g. NYM 2 x 1.5 mm 2 max. length 300 m max. 64 users/addresses (99 DALI loads, actuators, inputs) Line 2: DALI control line e.g. NYM 2 x 1.5 mm 2 max. length 300 m max. 64 users/addresses (99 DALI loads, actuators, inputs)
IR-TOUCH
14 / Chapter 5
Lighting/emergency lighting
L N DA DA DALI electronic ballast one4all (1 DALI load) K1 K 1' L K2 N K 2' DA K3 DA K 3' EMOTION-4RUKS K4 (1 DALI load) K 4' DA DA EMOTION-1RUK (10 DALI loads) L N DA DA L' N EMOTION-APD (1 DALI load) max. 2 m TE one4all (1 DALI load) R G B DALI-LED converter (1 DALI load) L' N EMOTION-ANAS (1 DALI load) L N DA DA D1 D2 D1 D2 25 DSI luminaires 25 DSI luminaires NV halogen incandescent lamps Incandescent lamps/ HV halogen incandescent lamps K K' e.g. incandescent lamps 12 11 10 9 Fluorescent lamps T26/T16 TC-L/TC-DEL/TC-TEL
L N DA DA
DA DA
L N DA DA
LED luminaires
L N DA DA
L N DA DA Locally supplied emergency luminaire LOCAL CHECK NT1 NT3 LDE DO (2 DALI loads) L N DA DA Escape-sign luminaire LOCAL CHECK (1 DALI load) L N DA DA CTC luminaire (e.g. TEMPURA)
Chapter 5 / 15
Sensors
Control points
Windows
Screens Blinds
LUXMATE bus
LITENET netlink
TCP/IP
LITENET flexisN2 without rotating parts (wear-free) optional LITENET incontrol operating software
Sensors
Control points
Windows
Screens Blinds
LUXMATE bus
LITENET netlink
TCP/IP
LITENET compact up to 2,000 output addresses no server required LITENET flexis N3 in 19" rack
fail-safe thanks to RAID1 optional LITENET incontrol operating software optional BACnet and OPC interfaces
16 / Chapter 5
Sensors
Control points
Windows
Screens Blinds
LUXMATE bus
LITENET server
TCP/IP
LITENET flexis N1
LITENET flexis N1
LITENET netlink
LITENET netlink
LITENET flexibel up to 10,000 output addresses (or more upon request) can be cascaded as required LITENET flexis N1 installed in switch cabinet
LITENET server extremely fail-safe thanks to RAID1 optional LITENET incontrol operating software optional BACnet and OPC interfaces
Chapter 5 / 17
LM-CS(X) control point RS 232 link to AV system ASCI plain text protocol B1, B2 LM-SI03 L, N IRS B1, B2, L, N
24VDC 24VAC
B 1 , B 2 , L, N B 1 , B 2 , L, N
B1, B2 L, N
230 VAC
B1 , B2
LUXMATE bus Mains DSI- or DALI control line Sensor cable For dimming and switching individual luminaire groups
L, N
L, N
L, N
B1, B2 LM-2FSE
L, N
Motor 1
Window
Window LM-BVS35
B1, B2
L, N
18 / Chapter 5
Lighting management
LM-2RUK L, N B1, B2 K', K L, N Electronic/conventional ballast for discharge lamps HIT/HST/HME lamps
Switching
LM-DSI L, N B1, B2 up to 10 DSI electronic ballasts D1, D2 D1, D2 L, N
Fluorescent lamps
DSI dimming
up to 10 DSI electronic ballasts up to 10 DALI electronic ballasts LM-2TL LM-2TL DALI L, N B1, B2 D1, D2 D1, D2 L, N D1, D2 Fluorescent lamps LSD option to connect a daylight sensor to the LM-2TL or LM-2TL/DALI up to 10 DSI electronic ballasts up to 10 DALI electronic ballasts D1, D2 L, N
DALI dimming
LM-DALIS
locally supplied LOCAL CHECK emergency luminaire LOCAL CHECK escape-sign luminaire
Chapter 5 / 19
Chapter 6
ECOOS ID T16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAREENA A/E LED 935 . . . . . . . . . . . . . . . . . . . . . . . . MELLOW LIGHT IV Microprismatic (recessed) . . . . . . . MELLOW LIGHT V Microprismatic (surface-mounted) . . MELLOW LIGHT V Microvane optic (surface-mounted) . MELLOW LIGHT V EM/EV LED . . . . . . . . . . . . . . . . . . . MIREL2 FEC2 ADV T16 . . . . . . . . . . . . . . . . . . . . . . . . MIREL2 FEC2 T16. . . . . . . . . . . . . . . . . . . . . . . . . . . . MIREL RES-BWS T16 . . . . . . . . . . . . . . . . . . . . . . . . . MIRAL RAS-BWS T16 . . . . . . . . . . . . . . . . . . . . . . . . . MIRAL2 FAC2 T16 . . . . . . . . . . . . . . . . . . . . . . . . . . . CLARIS II MD-ID T16. . . . . . . . . . . . . . . . . . . . . . . . . . CLARIS II MD-D T16 . . . . . . . . . . . . . . . . . . . . . . . . . . CLARIS II MC-ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Free-standing uplights . . . . . . . . . . . . . . . . . . . . . . . . TECTON(-I) + RW T16. . . . . . . . . . . . . . . . . . . . . . . . . TECTON-I IP + louvre T16. . . . . . . . . . . . . . . . . . . . . . TECTON-D ML-B and ML-C. . . . . . . . . . . . . . . . . . . . . TECTON-I D-ID + D-I . . . . . . . . . . . . . . . . . . . . . . . . . TECTON-I D PL (Poollight) . . . . . . . . . . . . . . . . . . . . . . SOLINA-D/I. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COPA I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COPA D TC-TELI RKF/RKID . . . . . . . . . . . . . . . . . . . . . COPA D HQI-T/HIT . . . . . . . . . . . . . . . . . . . . . . . . . . . COPA A-B 250 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . COPA A-B 400 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . PERLUCE D/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHIARO FTR 390 / FTR 680 T16-R . . . . . . . . . . . . . . . SCUBA T16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCUBA T26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLEAN C-O / C-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLEAN A-O / A-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLEAN S-C / S-R . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37 38 39 40 42 43 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76
Efficiency method
The Quickplan graphs have been calculated using the efficiency method. The following formulae can be used to give an approximate figure for the mean illuminance and the number of luminaires required. Em = n z L WF B A n= Em A z L WF B n = number of luminaires MF = maintenance factor A = floor area
Em = mean illuminance z = number of lamps per luminaire L = luminous flux of the lamp* B = utilization factor (= LB R ) LB = luminaire efficiency R = room utilization factor
standard UGR values and maintained luminance levels for luminance limit angle (e.g. 65 or 75) all around the luminaire correction factors for dark rooms and different ceiling heights (no. of luminaires x factor) maintenance factor uses an assumed value (graphs calculated using MF = 0.8) uniformity: max. luminaire spacing to achieve a uniformity greater than or equal to 0.7
Please note: with maximum spacing between luminaires, the illuminance level required is usually not achieved. * Luminaire efficiency generally relates to laboratory measurements at an ambient temperature of 25 C. For designing, it is therefore required to use the rated luminous flux levels of lamps at 25 C in the calculation programmes and/or when applying the efficiency method. Today, these values are usually calculated on a computer-aided basis, by accessing luminaire databases.
Chapter 6 / 3
500 lx 300 lx
54
HL/HM 27 W
90
4 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
HF/HG 27 W
80
70
Ceiling height: 3 m PANOS INF E150 HF 27 W LED WN PANOS INF E150 HG 27 W LED WN PANOS INF E150 HL 27 W LED WN PANOS INF E150 HM 27 W LED WN
UGR_axial UGR_transv. 65 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19 < 25 < 25 < 19 < 200 cd/m < 19
60
50
40
30
20
10
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
54
LL/LM 27 W
90
LF/LG 27 W
80
70
Ceiling height: 3 m PANOS INF E150 LF PANOS INF E150 LG PANOS INF E150 LL PANOS INF E150 LM
UGR_axial UGR_transv. < 25 < 25 < 25 < 25 < 25 < 25 < 25 < 25
60
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 5
Floor area m
500 lx 300 lx
54
HM 27 W
90
6 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
HG 27 W
HL 27 W
80
70
Ceiling height: 3 m PANOS INF E200 HF 27 W LED WN PANOS INF E200 HG 27 W LED WN PANOS INF E200 HL 27 W LED WN PANOS INF E200 HM 27 W LED WN
UGR_axial UGR_transv. 65 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19 < 25 < 25 < 19 < 200 cd/m < 19
60
HF 27 W
50
40
30
20
10
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
54
LL 27 W LM 27 W
90
LG 27 W
80
70
Ceiling height: 3 m PANOS INF E200 LF PANOS INF E200 LG PANOS INF E200 LL PANOS INF E200 LM
UGR_axial UGR_transv. 65 < 22 < 200 cd/m < 22 < 22 < 200 cd/m < 22 < 25 < 25 < 22 < 200 cd/m < 22
60
LF 27 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 7
Floor area m
500 lx 300 lx
54
HL/HM 36 W
90
8 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
HF/HG 36 W
80
70
Ceiling height: 3 m PANOS INF E200 HF 36 W LED WW PANOS INF E200 HG 36 W LED WW PANOS INF E200 HL 36 W LED WW PANOS INF E200 HM 36 W LED WW
UGR_axial UGR_transv. 65 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19 < 22 < 22 < 19 < 200 cd/m < 19
60
50
40
30
20
10
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
54
LL/LM 36 W
90
LF/LG 36 W
80
70
Ceiling height: 3 m PANOS INF E200 LF PANOS INF E200 LG PANOS INF E200 LL PANOS INF E200 LM
UGR_axial UGR_transv. < 25 < 25 < 25 < 25 < 25 < 25 < 25 < 25
60
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 9
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
PANOS HF 200/250
1/57 W (250)
Ceiling height: 3 m PANOS HF 200 1/32 W TC-TEL PANOS HF 200 1/42 W TC-TEL PANOS HF 250 1/32 W TC-TEL PANOS HF 250 1/42 W TC-TEL PANOS HF 250 1/57 W TC-TEL
UGR_axial UGR_transv. 65 < 16 < 500 cd/m < 16 < 19 < 500 cd/m < 19 < 16 < 200 cd/m < 16 < 16 < 200 cd/m < 16 < 19 < 200 cd/m < 19
1/42 W (250)
1/32 W (200)
1/42 W (200)
1/32 W (250)
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
PANOS HF 200/250
2/42 W (250)
Ceiling height: 3 m PANOS HF 200 2/14 W TC-TEL PANOS HF 200 2/17 W TC-TEL PANOS HF 250 2/32 W TC-TEL PANOS HF 250 2/42 W TC-TEL
UGR_axial UGR_transv. 65 < 19 < 500 cd/m < 19 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19
2/32 W (250)
2/14 W (200)
2/17 W (200)
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Chapter 6 / 11
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
Ceiling height: 3 m PANOS HG 200 1/32 W TC-TEL PANOS HG 200 1/42 W TC-TEL PANOS HG 200 2/14 W TC-TEL PANOS HG 200 2/17 W TC-TEL PANOS HG 250 1/32 W TC-TEL PANOS HG 250 1/42 W TC-TEL PANOS HG 250 2/32 W TC-TEL
UGR_axial UGR_transv. 65 < 16 < 500 cd/m < 16 < 19 < 500 cd/m < 19 < 19 < 500 cd/m < 19 < 19 < 200 cd/m < 19 < 16 < 200 cd/m < 16 < 16 < 200 cd/m < 16 < 19 < 200 cd/m < 19
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
Ceiling height: 3 m PANOS HG 175 2/18 W TC-DEL PANOS HG 200 2/18 W TC-DEL PANOS HG 200 2/26 W TC-DEL PANOS HG 250 2/26 W TC-DEL
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 19 < 19 < 500 cd/m < 19 < 22 < 200 cd/m < 19 < 19 < 200 cd/m < 19
2/26 W (200)
2/18 W (175)
2/18 W (200)
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Chapter 6 / 13
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
Ceiling height: 3 m PANOS LG 200 1/26 W TC-TEL PANOS LG 200 1/32 W TC-TEL PANOS LG 200 2/14 W TC-TEL PANOS LG 200 2/17 W TC-TEL PANOS LG 200 2/18 W TC-DEL PANOS LG 200 2/26 W TC-DEL
UGR_axial UGR_transv. < 22 < 22 < 22 < 22 < 22 < 22 < 22 < 22 < 22 < 22 < 25 < 25
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
M LG 2/32 W
90
LG 1/42 W
LG 2/32 W
80
70
Ceiling height: 3 m PANOS LG 250 1/32 W TC-TEL PANOS LG 250 1/42 W TC-TEL PANOS LG 250 2/32 W TC-TEL PANOS M LG 250 2/32 W TC-TEL
UGR_axial UGR_transv. < 22 < 22 < 25 < 22 < 28 < 25 < 25 < 25
60
LG 1/32 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 15
Floor area m
500 lx 300 lx
36 30 24 18 12 6
60
16 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
150 1/70 W
250 1/70 W
50
UGR_axial UGR_transv. Ceiling height: 3 m PANOS S 150 1/35 W HIT-TC-CE G8.5 < 19 < 19 < 22 PANOS S 150 1/70 W HIT-CE G8.5 < 22 < 28 PANOS S 250 1/70 W HIT-DE < 28
40
150 1/35 W
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
HIT G12 1/150 W
PANOS S 200
54 48 42 36 30 24 18 12 6 180 200
90
80
70
Ceiling height: 3 m PANOS S 200 1/100 W QR 111 PANOS S 200 1/100 W QT-LP 12 PANOS S 200 1/100 W HST GX12 PANOS S 200 1/150 W HIT G12
UGR_axial UGR_transv. < 13 < 13 < 16 < 16 < 19 < 19 < 22 < 22
60
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 17
Floor area m
Uniformity Max. axial spacing up to 1.6 m (QR), 1.8 m (QT-LP), 2.3 m (HST, HIT)
500 lx 300 lx
54
LM 1/32 W
PANOS Q Low
Correction factors Dark room (50/40/20): 1.1
48 42 36 30 24 18 12 6 180 200
90
LG 1/32 W
LL 1/32 W
18 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
80
70
Ceiling height: 3 m PANOS Q LF 190 1/32 W TC-TELI PANOS Q LG 190 1/32 W TC-TELI PANOS Q LL 190 1/32 W TC-TELI PANOS Q LM 190 1/32 W TC-TELI
UGR_axial UGR_transv. < 25 < 22 < 25 < 22 < 28 < 25 < 25 < 25
60
LF 1/32 W
50
40
30
20
10
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
54
2/32 W 2/42 W
PANOS Q High
Correction factors Dark room (50/40/20): 1.1
48 42 36 30 24 18 12 6 180 200
90
2/18 W
2/26 W
80
70
Ceiling height: 3 m PANOS Q HG 250 2/18 W TC-TELI PANOS Q HG 250 2/26 W TC-TELI PANOS Q HG 250 2/32 W TC-TELI PANOS Q HG 250 2/42 W TC-TELI
UGR_axial UGR_transv. 65 < 16 < 200 cd/m < 16 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19 < 19 < 200 cd/m < 19
60
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 19
Floor area m
500 lx 300 lx
E3 2/55 W
2LIGHT
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
E3 1/80 W
UGR_axial UGR_transv. 65 Ceiling height: 3 m 55 < 16 2LIGHT MINI A1 1/20 W HIT WFL < 1000 cd/m < 200 cd/m < 16 < 19 < 1000 cd/m 2LIGHT E1 1/42 W TC-TELI < 19 < 22 2LIGHT E2 2/42 W TC-TELI < 22 < 19 2LIGHT E1 1/70 W HIT G8.5 TI < 16 < 200 cd/m < 25 2LIGHT E3 1/80 W TC-L MDW < 19 < 25 2LIGHT E3 2/55 W TC-L MDW < 22
A1 1/20 W
E1 1/42 W
E2 2/42 W E1 1/70 W
40 30 20 10 00 90 80 70 60 50 40 30 20 10
2000 h 1 year 1 year
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
180
200
Floor area m
Uniformity Max. axial spacing up to 1.1 m (1/20 W**) 2.2 m (1/70 W*), 4 m (1/42 W), 4.7 m (2/42 W, 1/80 W, 2/55 W)
500 lx 300 lx
36
HA ID 2/80 W
VAERO-HA ID T16
Correction factors Dark room (50/40/20): 1.25
30 24 18 12 6
60
50
Ceiling height: 3 m VAERO-HA ID 2/35 W T16 VAERO-HA ID 2/49 W T16 VAERO-HA ID 2/54 W T16 VAERO-HA ID 2/80 W T16
UGR_axial UGR_transv. 55 65 < 13 < 13 < 1500 cd/m < 1000 cd/m < 13 < 1500 cd/m < 13 < 13 < 13 < 13 < 13
HA ID 2/54 W
40
HA ID 2/35 W
HA ID 2/49 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 21
Floor area m
500 lx 300 lx
36
SA ID 2/54 W
VAERO-SA ID T16
Correction factors Dark room (50/40/20): 1.25
30 24 18 12 6
22 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
60
50
Ceiling height: 3 m VAERO-SA ID 2/35 W T16 VAERO-SA ID 2/49 W T16 VAERO-SA ID 2/54 W T16
UGR_axial UGR_transv. 55 65 < 13 < 13 < 1500 cd/m < 1000 cd/m < 13 < 13 < 1500 cd/m < 1000 cd/m < 13 < 13
SA ID 2/49 W
40
SA ID 2/35 W
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
Ceiling height: 3 m ELEEA LRO-D 1/28 W T16 AB ELEEA LRO-D 1/35 W T16 AB ELEEA LRO-D 1/49 W T16 AB ELEEA LRO-D 1/54 W T16 AB
UGR_axial UGR_transv. < 19 < 19 < 19 < 19 < 19 < 22 < 22 < 22
LRO-D 1/28 W
LRO-D 1/54 W
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Chapter 6 / 23
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.25
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
Ceiling height: 3 m ELEEA LRO-DI 1/28 W T16 AB ELEEA LRO-DI 1/35 W T16 AB ELEEA LRO-DI 1/49 W T16 AB ELEEA LRO-DI 1/54 W T16 AB
UGR_axial UGR_transv. < 16 < 16 < 16 < 16 < 16 < 19 < 19 < 19
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
36
D-D 2/35 W
60
D-D 2/28 W
50
40
Ceiling height: 3 m ELEEA D-D 1/28 W T16 AB ELEEA D-D 1/35 W T16 AB ELEEA D-D 1/54 W T16 AB ELEEA D-D 2/28 W T16 AB ELEEA D-D 2/35 W T16 AB
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 19 < 19 < 1000 cd/m < 19 < 22 < 1000 cd/m < 22 < 22 < 1500 cd/m < 22 < 22 < 1500 cd/m < 22
D-D 1/28 W
D-D 1/35 W
D-D 1/54 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 25
Floor area m
500 lx 300 lx
36
D-DI 2/49 W
60
26 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
D-DI 2/35 W
50
40
Ceiling height: 3 m ELEEA D-DI 1/35 W T16 AB ELEEA D-DI 1/54 W T16 AB ELEEA D-DI 2/28 W T16 AB ELEEA D-DI 2/35 W T16 AB ELEEA D-DI 2/49 W T16 AB
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 19 < 19 < 1000 cd/m < 19 < 19 < 1000 cd/m < 19 < 19 < 1000 cd/m < 19 < 19 < 1500 cd/m < 19
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
2/54 W 2/80 W
AERO II T16
Correction factors Dark room (50/40/20): 1.5
30 24 18 12 6
60
2/35 W
2/49 W
50
40
Ceiling height: 3 m AERO II 2/28 W T16 AERO II 2/35 W T16 AERO II 2/49 W T16 AERO II 2/54 W T16 AERO II 2/80 W T16
UGR_axial UGR_transv. 55 /65 < 13 < 1000 cd/m < 13 < 13 < 1000 cd/m < 13 < 13 < 1000 cd/m < 13 < 13 < 1500 cd/m < 13 < 13 < 1500 cd/m < 13
2/28 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 27
Floor area m
500 lx 300 lx
18
2/54 W 2/80 W
AERO II LED
Correction factors Dark room (50/40/20): 1.5
15 12 9 6 3
30
28 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/35 W
2/49 W
25
20
Ceiling height: 3 m AERO II 48 W / 65 LED 2/28 W T16 AERO II 60 W / 65 LED 2/35 W T16 AERO II 60 W / 65 LED 2/49 W T16 AERO II 60 W / 65 LED 2/54 W T16 AERO II 60 W / 65 LED 2/80 W T16
UGR_axial UGR_transv. < 13 < 13 < 13 < 13 < 13 < 13 < 13 < 13 < 13 < 13
2/28 W
15
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
2/35 W 4/14 W
LIGHT FIELDS A A
Correction factors Dark room (50/40/20): 1.1
30 24 18 12 6
60
2/28 W
50
Ceiling height: 3 m LIGHT FIELDS A A 2/28 W LIGHT FIELDS A A 2/35 W LIGHT FIELDS A A 4/14 W
UGR_axial UGR_transv. 65 < 16 < 1000 cd/m < 16 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m < 19
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 29
Floor area m
500 lx 300 lx
36
2/54 W 4/24 W
60
30 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/49 W
50
Ceiling height: 3 m LIGHT FIELDS A A-ID 2/49 W LIGHT FIELDS A A-ID 2/54 W LIGHT FIELDS A A-ID 4/24 W
UGR_axial UGR_transv. 65 < 13 < 1000 cd/m < 13 < 13 < 1000 cd/m < 13 < 13 < 1000 cd/m < 13
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
2/35 W 4/14 W
60
2/28 W
50
Ceiling height: 3 m L-FIELDS ADV A 2/28 W T16 L-FIELDS ADV A 2/35 W T16 L-FIELDS ADV A 4/14 W T16
UGR_axial UGR_transv. 65 < 19 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 31
Floor area m
500 lx 300 lx
36
2/54 W 4/24 W
60
32 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/49 W
50
Ceiling height: 3 m L-FIELDS ADV ID 2/49 W T16 L-FIELDS ADV ID 2/54 W T16 L-FIELDS ADV ID 4/24 W T16
UGR_axial UGR_transv. 65 < 13 < 13 < 1000 cd/m < 13 < 13 < 1500 cd/m < 13 < 13 < 1000 cd/m
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
2/35 W 4/14 W
60
2/28 W
50
Ceiling height: 3 m L-FIELDS ADV E 2/28 W T16 L-FIELDS ADV E 2/35 W T16 L-FIELDS ADV E 4/14 W T16
UGR_axial UGR_transv. 65 < 19 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 33
Floor area m
500 lx 300 lx
36
2/35 W 4/14 W
L-FIELDS E T16
Correction factors Dark room (50/40/20): 1.1
30 24 18 12 6
60
34 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/24 W
2/28 W
50
55 UGR_axial UGR_transv. 65 Ceiling height: 3 m < 1500 cd/m L-FIELDS E 2/24 W T16 < 16 < 16 < 1000 cd/m L-FIELDS E 2/28 W T16 < 16 < 16 < 1000 cd/m L-FIELDS E 2/35 W T16 < 16 < 16 < 1000 cd/m L-FIELDS E 4/14 W T16 < 16 < 16
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
Ceiling height: 3 m LIGHT FIELDS E 1/42 W TC-TELI LIGHT FIELDS E 2/32 W TC-TELI
40 30 20 10 00 90 80 70 60 50 40 30 20 10 180 200
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Chapter 6 / 35
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.25
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
ECOOS A T16
1/35 W 1/54 W
40 30 20 10 00 90 80 70 60 50 40 30 20 10 180 200
Ceiling height: 3 m ECOOS A 1/28 W T16 ECOOS A 1/35 W T16 ECOOS A 1/54 W T16
UGR_axial UGR_transv. 65 < 16 < 16 < 1500 cd/m < 16 < 16 < 1500 cd/m < 19 < 16
1/28 W
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.25
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
ECOOS ID T16
1/49 W 1/54 W
Ceiling height: 3 m ECOOS ID 1/28 W T16 ECOOS ID 1/35 W T16 ECOOS ID 1/49 W T16 ECOOS ID 1/54 W T16
UGR_axial UGR_transv. 65 < 16 < 1500 cd/m < 16 < 16 < 1500 cd/m < 16 < 16 < 16 < 19 < 16
1/28 W
1/35 W
40 30 20 10 00 90 80 70 60 50 40 30 20 10 180 200
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Chapter 6 / 37
Floor area m
500 lx 300 lx
36 30 24 18 12 6
38 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
60
50
Ceiling height: 3 m CAREENA A 52 W LED 935 CAREENA E 52 W LED 935 M600 CAREENA E 52 W LED 935 M625
UGR_axial UGR_transv. 55 65 < 16 < 16 < 1500 cd/m < 1000 cd/m < 19 < 19 < 16 < 16 < 1500 cd/m
E 52 W M600 E 52 W M625
40
A 52 W
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
AM 2/49 W T16
60
AM 2/40 W TC-L
50
40
Ceiling height: 3 m ML IV A AM 1/54 W T16 ML IV B AM 2/24 W T16 ML IV B AM 2/24 W + 2/24 W T16 ML IV B AM 2/40 W TC-L ML IV A AM 2/49 W T16
UGR_axial UGR_transv. < 19 < 16 < 22 < 16 < 25 < 19 < 25 < 19 < 22 < 19
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 39
Floor area m
Uniformity Max. axial spacing up to 6.8 m (2/24W + 2/24 W, 2/40 W), 5.9 m (2/24 W), 5.2m (1/54 W, 2/49 W)
500 lx 300 lx
36
1/49 W 1/54 W
60
40 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
1/28 W
1/35 W
50
Ceiling height: 3 m MELLOW LIGHT V EM 1/28 W T16 M600/M625 MELLOW LIGHT V EM 1/35 W T16 M625 MELLOW LIGHT V EM 1/49 W T16 M625 MELLOW LIGHT V EM 1/54 W T16 M600/M625
UGR_axial UGR_transv. < 19 < 19 < 19 < 19 < 22 < 19 < 22 < 19
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36 30
EM 1/55 W 600/625
60
50 24 18 12 6
Ceiling height: 3 m MELLOW LIGHT V EM 1/40 W TC-L M600 MELLOW LIGHT V EM 1/40 W TC-L M625 MELLOW LIGHT V EM 1/55 W TC-L M600 MELLOW LIGHT V EM 1/55 W TC-L M625
UGR_axial UGR_transv. < 19 < 19 < 19 < 19 < 19 < 19 < 19 < 19
40
EM 1/40 W 600/625
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 41
Floor area m
500 lx 300 lx
36 30 24 18 12 6
42 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
60
50
40
Ceiling height: 3 m MELLOW LIGHT V EM 2/24 W T16 MELLOW LIGHT V EM 2/28 W T16 MELLOW LIGHT V EM 2/35 W T16 MELLOW LIGHT V EM 2/40 W TC-L MELLOW LIGHT V EM 2/49 W T16 MELLOW LIGHT V EM 2/54 W T16
UGR_axial UGR_transv. < 19 < 19 < 22 < 19 < 22 < 19 < 22 < 22 < 22 < 22 < 22 < 22
30
EM 2/24 W T16
EM 2/28 W T16
EM 2/35 W T16
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36 30 24 18 12 6
60
EV 1/49 W
EV 1/54 W
50
65 Ceiling height: 3 m UGR_axial UGR_transv. < 19 MELLOW LIGHT V EV 1/28 W T16 M625 < 19 < 500 cd/m < 19 MELLOW LIGHT V EV 1/35 W T16 M625 < 19 < 500 cd/m < 16 MELLOW LIGHT V EV 1/49 W T16 M625 < 16 < 1000 cd/m < 16 MELLOW LIGHT V EV 1/54 W T16 M625 < 16 < 1000 cd/m
40
EV 1/28 W
EV 1/35 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 43
Floor area m
500 lx 300 lx
36
2/49 W 2/54 W
60
44 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/35 W
50
40
65 Ceiling height: 3 m UGR_axial UGR_transv. < 1500 cd/m < 19 MELLOW LIGHT V EV 2/24 W T16 M600/M625 < 16 < 1500 cd/m < 16 MELLOW LIGHT V EV 2/28 W T16 M600/M625 < 16 < 1500 cd/m < 19 MELLOW LIGHT V EV 2/35 W T16 M625 < 19 < 1500 cd/m < 19 MELLOW LIGHT V EV 2/49 W T16 M625 < 19 < 19 MELLOW LIGHT V EV 2/54 W T16 M600/M625 < 19
2/24 W
2/28 W
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
EV 2/40 W
60
EV 1/55 W
50
65 UGR_axial UGR_transv. Ceiling height: 3 m < 1000 cd/m < 16 MELLOW LIGHT V EV 1/40 W TC-L M600/M625 < 16 < 1500 cd/m < 16 MELLOW LIGHT V EV 1/55 W TC-L M600/M625 < 16 < 16 MELLOW LIGHT V EV 2/40 W TC-L M600/M625 < 19
40
EV 1/40 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 45
Floor area m
500 lx 300 lx
36
EV 60 W LED
60
46 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
EM 60 W LED
50
UGR_axial UGR_transv. 65 Ceiling height: 3 m MELLOW LIGHT V EM 60 W LED M600/M625 < 22 < 19 MELLOW LIGHT V EV 60 W LED M600/M625 < 16 < 16 < 1000 cd/m
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
1/49 W 1/54 W
60
1/28 W
1/35 W
50
Ceiling height: 3 m MIREL2 FEC2 ADV 1/28 W T16 MIREL2 FEC2 ADV 1/35 W T16 MIREL2 FEC2 ADV 1/49 W T16 MIREL2 FEC2 ADV 1/54 W T16
UGR_axial UGR_transv. 65 < 19 < 500 cd/m < 19 < 19 < 500 cd/m < 19 < 16 < 500 cd/m < 19 < 19 < 1000 cd/m < 19
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 47
Floor area m
500 lx 300 lx
36
2/49 W 2/54 W
60
48 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/28 W
2/35 W
50
Ceiling height: 3 m MIREL2 FEC2 ADV 2/28 W T16 MIREL2 FEC2 ADV 2/35 W T16 MIREL2 FEC2 ADV 2/49 W T16 MIREL2 FEC2 ADV 2/54 W T16
UGR_axial UGR_transv. 65 < 19 < 500 cd/m < 19 < 19 < 500 cd/m < 19 < 19 < 1000 cd/m < 19 < 16 < 500 cd/m < 19
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36 30 24 18 12 6
60
2/24 W
2/54 W
50
40
UGR_axial UGR_transv. 65 Ceiling height: 3 m < 19 < 500 cd/m MIREL2 FEC2 1/28 W T16 M600/625 < 19 < 19 < 500 cd/m MIREL2 FEC2 1/35 W T16 M600/625 < 19 < 19 < 500 cd/m MIREL2 FEC2 1/54 W T16 M625 < 19 < 19 < 500 cd/m MIREL2 FEC2 2/24 W T16 M600/625 < 19 < 19 < 500 cd/m MIREL2 FEC2 2/54 W T16 M600/625 < 19
1/28 W
1/35 W
1/54 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 49
Floor area m
500 lx 300 lx
18
3/80 W 4/80 W
30
50 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
1/80 W
2/54 W
25
Ceiling height: 3 m MIRAL/MIREL RES-BWS 1/80 W T16 MIRAL/MIREL RES-BWS 2/54 W T16 MIRAL/MIREL RES-BWS 3/80 W T16 MIRAL/MIREL RES-BWS 4/80 W T16
UGR_axial UGR_transv. < 16 < 19 < 19 < 22 < 16 < 19 < 19 < 22
20
15
10
20
40
60
80
100
120
140
160
180
200
Floor area m
Uniformity Max. axial spacing up to 4 m (RES 1/80 W, 2/54 W), 4.7 m (RES 3/80 W, 4/80 W)
500 lx 300 lx
18
3/80 W 4/80 W
30
1/80 W
2/80 W
25
Ceiling height: 3 m MIRAL/MIREL RAS-BWS 1/80 W T16 MIRAL/MIREL RAS-BWS 2/80 W T16 MIRAL/MIREL RAS-BWS 3/80 W T16 MIRAL/MIREL RAS-BWS 4/80 W T16
UGR_axial UGR_transv. < 16 < 19 < 19 < 22 < 16 < 19 < 19 < 22
20
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
15
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 51
Floor area m
Uniformity Max. axial spacing up to 3.9 m (RAS 1/80W, 2/80W), 3.5 m (RAS 3/80 W, 4/80 W)
500 lx 300 lx
54
2/54 W 4/14 W
90
1/54 W
2/49 W
52 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
80
70
60
Ceiling height: 3 m MIRAL2 FAC2 1/28 W T16 MIRAL2 FAC2 1/49 W T16 MIRAL2 FAC2 1/54 W T16 MIRAL2 FAC2 2/49 W T16 MIRAL2 FAC2 2/54 W T16 MIRAL2 FAC2 B 4/14 W T16
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 19 < 19 < 1000 cd/m < 19 < 19 < 1500 cd/m < 19 < 22 < 22 < 22 < 22 < 19 < 1000 cd/m < 19
50
1/28 W
1/49 W
40
30
20
10
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
36
2/35 W 2/54 W
60
1/35 W
1/54 W
50
Ceiling height: 3 m CLARIS II MD-ID 1/35 W T16 CLARIS II MD-ID 1/54 W T16 CLARIS II MD-ID 2/35 W T16 CLARIS II MD-ID 2/54 W T16
UGR_axial UGR_transv. 65 < 13 < 13 < 500 cd/m < 16 < 13 < 500 cd/m < 13 < 16 < 1000 cd/m < 16 < 16 < 1000 cd/m
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 53
Floor area m
500 lx 300 lx
Correction factors Dark room (50/40/20): 1.1
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
40 30 20 10 00 90 80 70 60 50 40 30 20 10 180 200
Ceiling height: 3 m CLARIS II MD-D 1/28 W T16 CLARIS II MD-D 1/35 W T16 CLARIS II MD-D 1/49 W T16 CLARIS II MD-D 1/54 W T16
UGR_axial UGR_transv. 65 < 19 < 500 cd/m < 19 < 19 < 500 cd/m < 19 < 19 < 500 cd/m < 19 <19 < 500 cd/m < 19
1/28 W
1/35 W
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
Floor area m
500 lx 300 lx
36
2/35 W 2/54 W
CLARIS II MC-ID
Correction factors Dark room (50/40/20): 1.25
30 24 18 12 6
60
1/35 W
1/54 W
50
Ceiling height: 3 m CLARIS II MC-ID 1/35 W T16 CLARIS II MC-ID 1/54 W T16 CLARIS II MC-ID 2/35 W T16 CLARIS II MC-ID 2/54 W T16
UGR_axial UGR_transv. 65 < 13 < 13 < 1500 cd/m < 16 < 16 < 13 < 16 < 1000 cd/m < 16 < 16
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 55
Floor area m
500 lx 300 lx
18
OPURA-S
Free-standing uplights
Correction factors Dark room (50/40/20): 1.5
15 12 9 6 3
30
56 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.3 1.3 5m 1,7 1.4 6m 2,2 1.5
LANOS-S
KAREA-S
25
20
Ceiling height: 3 m LIGHT FIELDS-S 3/55 W TC-L LIGHT FIELDS-S 3/80 W TC-L CAPA-S-P, CAPA-S-L 4/28 W TC-L CAPA-S-P, CAPA-S-L 4/55 W TC-L LANOS-S SYM 4/55 W TC-L KAREA-S SYM 4/55 W TC-L OPURA-S 3/55 W TC-L
UGR_axial UGR_transv. 65 < 13 < 1500 cd/m < 13 < 13 < 1500 cd/m < 13 < 13 < 13 < 13 < 13 < 13 < 13 < 13 < 13 < 16 < 13
15
L-FIELDS-S 55 W
L-FIELDS-S 80 W
CAPA-S 28 W
CAPA-S 55 W
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
-I 2/54 W + R
TECTON(-I) + RW T16
Correction factors Dark room (50/40/20): 1.1
30 24 18 12 6
60
2/54 W + RW
50
Ceiling height: 3 m TECTON 1/54 W T16 + RW TECTON 1/54 W T16 + PK+ RW TECTON 2/54 W T16 + RW TECTON-I 2/54 W T16 + R
UGR_axial UGR_transv. > 28 < 28 > 28 < 22 > 28 < 28 > 28 < 28
40
1/54 W + RW 1/54 W + PK + RW
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 57
Floor area m
500 lx 300 lx
36
-I 2/80 W + R
TECTON(-I) + RW T16
Correction factors Dark room (50/40/20): 1.1
30 24 18 12 6
60
58 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/80 W + RW
50
Ceiling height: 3 m TECTON 1/80 W T16 + RW TECTON 1/80 W T16 + PK+ RW TECTON 2/80 W T16 + RW TECTON-I 2/80 W T16 + R
UGR_axial UGR_transv. > 28 < 25 > 28 < 22 > 28 < 28 > 28 < 28
40
1/80 W + RW
1/80 W +PK + RW
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
2/54 W 2/80 W
60
1/54 W
1/80 W
50
Ceiling height: 3 m TECTON-I IP 1/54 W T16 TECTON-I IP 1/80 W T16 TECTON-I IP 2/54 W T16 TECTON-I IP 2/80 W T16
UGR_axial UGR_transv. < 22 < 22 < 22 < 22 < 22 < 22 < 25 < 22
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 59
Floor area m
500 lx 300 lx
36
ML-C 2/54 W
60
60 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
ML-C 2/49 W
50
Ceiling height: 3 m TECTON-D ML-B 2/49 W T16 TECTON-D ML-B 2/54 W T16 TECTON-D ML-C 2/49 W T16 TECTON-D ML-C 2/54 W T16
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 22 < 19 < 1000 cd/m < 22 < 19 < 1500 cd/m < 16 < 19 < 1000 cd/m < 16
40
ML-B 2/49 W
ML-B 2/54 W
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
18
D-I 2/80 W
30
D-I 2/54 W
25
UGR_axial UGR_transv. 55 Ceiling height: 3 m < 19 TECTON-I D-ID 2/54 W T16 < 19 < 19 TECTON-I D-ID 2/80 W T16 < 19 < 13 < 500 cd/m TECTON-I D-I 2/54 W T16 < 13 < 19 < 500 cd/m TECTON-I D-I 2/80 W T16 < 19
65 < 1000 cd/m < 1000 cd/m < 500 cd/m < 500 cd/m
20
D-ID 2/54 W
D-ID 2/80 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
15
10
2000 h
1 year / year*
1 year
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 61
Floor area m
500 lx 300 lx
18
2/49 W 2/80 W
TECTON-I D PL (Poollight)
Correction factors Dark room (50/40/20): 1.25
15 12 9 6 3
30
62 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/35 W
25
Ceiling height: 3 m TECTON-I D PL 2/35 W T16 TECTON-I D PL 2/49 W T16 TECTON-I D PL 2/80 W T16
20
15
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
HIT 1/150 W
SOLINA D/I
Correction factors Dark room (50/40/20): 1.1
30 24 18 12 6
Lamp operation Luminaire maintenance Room maintenance
60
HIT 1/70 W
50
Ceiling height: 3 m SOLINA D/I 1/42 W SOLINA D/I 1/57 W SOLINA D/I 1/70 W SOLINA D/I 1/150 W
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 19 < 22 < 22 < 19 < 1500 cd/m < 19 < 22 < 22
40
TC-TELI 1/42 W
TC-TELI 1/57 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 63
Floor area m
500 lx 300 lx
18 15 12 9 6 3
COPA I
Correction factors Dark room (50/40/20): 1.1 Maintenance factor (WF)
30
64 / Chapter 6
Clean large room WF = 0.77 HQI WF = 0.77 NAV Lamp operation 4000 h 8000 h Cleaning of lum. (IP65) 1 year 3 years Room maintenance 1 year 3 years
25
Ceiling height: 6 m COPA I 1/250 W HQI-E/D-PRO RAB TST COPA I 1/250 W NAV-E RAB TST COPA I 1/400 W HQI-E/N + RAB COPA I 1/400 W NAV-E + RAB
UGR_axial UGR_transv. 65 < 16 < 500 cd/m < 16 < 19 < 500 cd/m < 19 < 25 < 25 < 25 < 25
20
15
10
Uniformity Max. axial spacing up to 5.6 m (1/250W HQI-E), 6.5 m (1/250 W NAV-E), 10.2 m (1/400 W HQI-E/N), 9.8 m (1/400 W NAV-E)
50
100
150
200
250
300
350
400
450
500
Floor area m
= Colour rendering index Ra 90 = Colour rendering index Ra 25 = Colour rendering index Ra 65 = Colour rendering index Ra 25
500 lx 300 lx
36
1/57 W RKID
60 30 24 18 12 6
1/57 W RKF
50
Ceiling height: 4 m COPA D 1/42 W TC-TELI + RKF COPA D 1/42 W TC-TELI + RKID COPA D 1/57 W TC-TELI + RKF COPA D 1/57 W TC-TELI + RKID
UGR_axial UGR_transv. 65 < 19 < 1000 cd/m < 19 < 19 < 1000 cd/m < 19 < 25 < 25 < 22 < 22
40
1/42 W RKF
1/42 W RKID
30
20
Clean medium-sized room Lamp operation Cleaning of luminaires (IP65) Room maintenance
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 65
Floor area m
500 lx 300 lx
18 15 12 9 6 3
Floor area Ceiling height up to 50 m over 50 m 5m 1.2 1.1 6m 1.4 1.2
30
25
Ceiling height: 6 m COPA D 1/70 W HQI-T (5800 lm) COPA D 1/70 W HCIT/P NDL (6700 lm) COPA D 1/150 W HCI-T/P NDL (14500 lm)
UGR_axial UGR_transv. 65 < 28 < 1000 cd/m < 28 < 19 < 1000 cd/m < 19 < 22 < 22
20
1/70 W HQI-T
15
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
18
2/250 W NAV-T
30
1/250 W NAV-T
25
Ceiling height: 6 m COPA A-B 1/250 W HQI-T/D (20000 lm) COPA A-B 2/250 W HQI-T/D (40000 lm) COPA A-B 1/250 W NAV-T (28000 lm) COPA A-B 2/250 W NAV-T (56000 lm)
UGR_axial UGR_transv. < 28 < 28 > 28 < 28 > 28 > 28 < 25 > 28
20
1/250 W HQI-T/D
2/250 W HQI-T/D
Clean large room WF = 0.77 (HQI) 0,81 (NAV) Lamp operation 2000 h 5000 h 1 year Cleaning of lum. (IP65) 1 year Room maintenance 2 years 2 years
15
10
Uniformity Max. axial spacing up to 7.9 m (2/250 W NAV-T), 9 m (2/250 W HQI-T/D), 11 m (1/250 W HQI-T/D, 1/250 W NAV-T)
HQIT/D = Colour rendering index Ra 90 NAV-T = Colour rendering index Ra 25
50
100
150
200
250
300
350
400
450
500
Chapter 6 / 67
Floor area m
500 lx 300 lx
18
1/400 W NAV-T
30 15 12 9 6 3
1/400 W HQI-T/N
25
Ceiling height: 6 m COPA A-B 1/400 W HQI-T/N (34000 lm) COPA A-B 1/400 W NAV-T (48000 lm)
20
15
10
50
100
150
200
250
300
350
400
450
500
Floor area m
500 lx 300 lx
O 2/18 W TC-L
PERLUCE D/O
Correction factors Dark room (50/40/20): 1.1 (D), 1.25 (O) Maintenance factor (WF)
O 1/49 W T16
Ceiling height: 3 m PERLUCE D 1/49 W T16 PERLUCE D 1/80 W T16 PERLUCE O 1/49 W T16 PERLUCE O 2/18 W TC-L
UGR_axial UGR_transv. 65 < 16 < 16 < 1000 cd/m < 19 < 19 < 1000 cd/m < 22 < 19 < 22 < 22
D 1/49 W T16
D 1/80 W T16
Clean large room WF = 0.77 (D) WF = 0.80 (O) Lamp operation 4000 h 2000 h 1 year Cleaning of lum. (IP54) 1 year Room maintenance 2 years 1 year
40 30 20 10 00 90 80 70 60 50 40 30 20 10
86 80 72 66 60 54 48 42 36 30 24 18 12 6
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 69
Floor area m
500 lx 300 lx
36
2/54 W T16
RAIN
Correction factors Dark room (50/40/20): 1.25
30 24 18 12 6
60
70 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
2/36 W T26
50
Ceiling height: 3 m RAIN 1/58 W T26 RAIN 1/80 W T16 RAIN 2/36 W T26 RAIN 2/54 W T16
UGR_axial UGR_transv. < 28 < 25 > 28 < 28 < 28 < 22 > 28 < 25
40
1/58 W T26
1/80 W T16
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
54
2/40 W T16-R
90
80
70
Ceiling height: 3 m CHIARO FTR 1/40 W T16-R 390 CHIARO FTR 1/55 W T16-R 390 CHIARO FTR 1/22 W + 40 W T16-R 390 CHIARO FTR 2/40 W T16-R 390
UGR_axial UGR_transv. < 22 < 22 < 22 < 22 < 22 < 22 < 22 < 22
60
1/40 W T16-R
1/55 W T16-R
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
40
30
20
10
20
40
60
80
100
120
140
160
Chapter 6 / 71
Floor area m
500 lx 300 lx
36
1/80 W 2/49 W
SCUBA T16
Correction factors Dark room (50/40/20): 1.25
30 24 18 12 6
60
72 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
1/49 W
1/54 W
50
40
Ceiling height: 3 m SCUBA PC 1/35 W T16 SCUBA PC 1/49 W T16 SCUBA PC 1/54 W T16 SCUBA PC 1/80 W T16 SCUBA PC 2/49 W T16
UGR_axial UGR_transv. < 22 < 19 < 25 < 19 < 25 < 22 < 25 < 22 < 28 < 22
1/35 W
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
2/58 W
SCUBA T26
Correction factors Dark room (50/40/20): 1.25
30 24 18 12 6
60
1/58 W
2/36 W
50
Ceiling height: 3 m SCUBA 1/36 W T26 SCUBA 1/58 W T26 SCUBA 2/36 W T26 SCUBA 2/58 W T26
UGR_axial UGR_transv. < 25 < 19 < 25 < 19 < 25 < 19 < 28 < 22
40
1/36 W
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 73
Floor area m
500 lx 300 lx
36
C-R 3/55 W TC-L
60
74 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
50
Ceiling height: 3 m CLEAN C-O 4/24 W T16 M625 CLEAN C-O 3/40 W TC-L M625 CLEAN C-R 3/55 W TC-L M625
40
30
20
10
20
40
60
80
100
120
140
160
180
200
Floor area m
500 lx 300 lx
36
A-C 3/55 W TC-L
60
50
Ceiling height: 3 m CLEAN A-O 2/49 W T16 M625 CLEAN A-C 2/49 W T16 M625 CLEAN A-C 3/40 W TC-L M625 CLEAN A-C 3/55 W TC-L M625
UGR_axial UGR_transv. 65 < 22 < 22 < 16 < 1000 cd/m < 19 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m < 19
40
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
30
20
10
20
40
60
80
100
120
140
160
180
200
Chapter 6 / 75
Floor area m
500 lx 300 lx
18
S-C 3/80 W
30
76 / Chapter 6
Floor area Ceiling height up to 50 m over 50 m 4m 1.2 1.1 5m 1.4 1.2 6m 1.6 1.3
S-R 2/49 W
S-C 3/49 W
25
Ceiling height: 3 m CLEAN S-R 2/49 W CLEAN S-C 3/49 W CLEAN S-C 3/80 W
UGR_axial UGR_transv. 65 < 22 < 22 < 16 < 19 < 1500 cd/m < 19 < 19 < 1500 cd/m
20
15
10
20
40
60
80
100
120
140
160
180
200
Floor area m
Chapter 7
Technical information
Protection classes. . . . . . . . . . . . . . . . . . . . . . . . . . . . Degrees of protection . . . . . . . . . . . . . . . . . . . . . . . . . Fire protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Explosion-proofness . . . . . . . . . . . . . . . . . . . . . . . . . . Requirements concerning safety ball-proofness . . . . . Clean-room technology . . . . . . . . . . . . . . . . . . . . . . . . Chemical effects on materials . . . . . . . . . . . . . . . . . . . Short-circuit protection and loading of circuits . . . . . . . Low-voltage installations . . . . . . . . . . . . . . . . . . . . . . . 3 35 67 89 10 11 13 14 16 17 24 25 27
Protection classes
Zumtobel luminaires are classified into the following protection classes a measure intended to afford protection against electric shock. Class I luminaires Class I is not identified by a symbol; the luminaire is intended to be connected to a protective earth conductor which bears the mark. Unless specified otherwise, all luminaires by Zumtobel comply at least with protection class I. Class II luminaires Class II luminaires have total insulation but no protective earth terminal. The Zumtobel range includes protection class II luminaires, for instance moisture-proof batten luminaires and moisture-proof diffuser luminaires. Class III luminaires Class III identifies luminaires that are intended for operation with protective extra low voltage (50 V max.). Zumtobel architectural luminaires include class III luminaires, e.g. PRIO low-voltage spotlights. Protection class I Protection class II Protection class III
Degrees of protection
Degrees of protection indicate the following properties of equipment: the quality of its protection against direct contact its sealing against ingress of solid foreign bodies (dust, stones, sand, etc.) its sealing against the ingress of water
Chapter 7 / 3
The type of protection is defined by two degrees of protection in accordance with IEC 529: degree of shock-hazard protection and protection against ingress of solid foreign bodies (1st digit) degree of protection against the ingress of water (2nd digit) For example IP23: IP
INGRESS PROTECTION Protection against ingress of solid foreign bodies having > 12 mm (medium-sized solid bodies), insertion of fingers or objects. Protection against ingress of water falling at any angle up to 60 from vertical. There must be no adverse effect (spray water).
Degrees of protection for technical luminaires: Protection against ingress of solid foreign bodies as per first digit IP0X IP1X IP2X IP3X IP4X IP5X IP6X Unprotected against ingress of solid foreign bodies Protection against solid bodies > 50 mm Protection against solid bodies > 12 mm Protection against solid bodies > 2.5 mm Protection against solid bodies > 1 mm Dust-protected (limited ingress of dust) Dust-tight (no ingress of dust)
Protection against moisture as per second digit IPX0 IPX1 IPX2 IPX3 IPX4 IPX5 IPX6 IPX7 IPX8 No special protection Drip-proof protection against water drops Protection against water drops up to 15 from the vertical Rainproof protection against spray water up to 60 Splash-proof protection against spray water from all directions Jet-proof protection against jets of water Protection against heavy seas (conditions on ship decks) Watertight protection against immersion (pressure and time specified) Protection against immersion under pressure (with instructions from manufacturer)
4 / Chapter 7
Applications for luminaires with increased protection: Damp locations Bakeries Manure sheds Animal-feed preparation facilities Industrial kitchens Boiler rooms Commercial workshops Granaries (Deep-freeze) cold storage Pump houses Sculleries Laundries Wet locations Beer or wine cellars Shower cubicles Meat processing facilities Electroplating facilities Greenhouses Dairies Workshops using wet processes Car wash areas Agricultural facilities IPX1 IPX1 IPX1 IPX1 IPX1 IP20 IPX1 IPX1 IPX1 IPX1 IPX1 IPX4 IPX4 IPX5 IPX4 IPX4 IPX4 IPX4 IPX4
The following generally applies: IPX5: for cleaning using water jets IPX4: in rinsing areas
The following generally applies: IPX5: for cleaning using water jets
Beer or wine cellars IP44 Shower cubicles IP44 Stores, storerooms for hay, straw, feedstuff IP44 Intensive stock farming IP44 Animal sheds IP44 Adjoining rooms of animal sheds IP44 Facilities with increased fire risk Workrooms Woodworking Sawmills Paper processing Textile processing Treatment and fabrication Gymnasia and sports halls
The Lighting Handbook
The following generally applies: IPX5: for cleaning using water jets IP54+FF: when increased fire risk
IP50 IP50 IP50 IP50 IP50 IP50 IP20 IP20 IP20 IP20
ballproof luminaires ballproof luminaires with all-round cover; maximum mesh size 60 mm
Badminton courts Squash courts Indoor tennis courts Gymnasia and sports halls
Chapter 7 / 5
Fire protection
Luminaire identification marking The following criteria must be taken into account: position of normal use fire behaviour of environment and mounting surfaces minimum clearance from combustible substances and materials Luminaires with thecmark Luminaires which carry thecmark must be constructed so that the temperature on the mounting surface does not exceed 130 C during abnormal operation, and does not exceed 180 C in the event of a ballast fault. Luminaires with this mark are suitable for direct mounting on parts of buildings made of non-combustible, flame-retardant or normally flammable building materials according to DIN 4102. /Umark Luminaires with the Both marks regulate the surface temperatures of luminaires. External surfaces on which readily flammable substances such as dust or fibrous materials may accumulate when luminaires are installed as prescribed must not exceed specific temperatures. The d luminaire mark was withdrawn in 1999. A validity transition period allows the d mark to be used until 01. 08. 2005. TheUmark introduced in EN 60598 has applied since 01.08.1998. The d mark limits the temperature on horizontal surfaces to 95 C during normal operation and 115 C in the event of a ballast fault. Temperatures must not exceed 220 C on vertical surfaces. In order to fulfil the criteria of the Umark, the surface temperature on horizontal surfaces must not exceed 90 C. The maximum temperature in the event of a fault is 115 C, the same as for the d mark. The temperature must not exceed 150 C on vertical surfaces. Luminaires with theQmark Luminaires which carry theQmark are intended for installation in furniture. They are designed so that in the event of a ballast fault, flame-retardant and normally flammable materials as specified in DIN 4102 cannot be ignited, e.g. in corners of wooden furniture. The materials may be painted, veneered or varnished. mark Luminaires with the Luminaires which carry the q mark are intended for mounting in or on furniture made of materials whose flammability is not known. They are designed so that in normal operation any mounting surface or other adjacent furniture surfaces do not exceed a temperature of 95 C. 6 / Chapter 7
Building parts made of non-combustible building materials according to DIN 4102 Part 1 Building parts made of flame-retardant building materials according to DIN 4102 Part 1 Facilities with increased fire risk according to DIN VDE 0100 Part 720
c U d
IP5X
Agricultural facilities with increased fire risk according to DIN VDE 0100 Part 720 IP54 DIN VDE 0100 Part 705 Installation VDS 8/83 Form 2033 marking Installation objects whose fire behaviour is specified as flame retardant or normally flammable in DIN 4102 Part 1 Installation objects with unknown fire behaviour
The Lighting Handbook
U d
Q
Permissive location markings
as per DIN VDE 0710 Part 14 on the mounting surface and adjacent surfaces
Mounting surface < 130 C < 180 C Operation abnormal ballast fault
q
Permissive location markings
as per DIN VDE 0710 Part 14 on the mounting surface and adjacent surfaces
Mounting surface < 95 C < 130 C < 130 C Operation normal abnormal ballast fault
Chapter 7 / 7
Explosion-proofness
Flammable gases, vapours and mists Zone O A hazardous explosive atmosphere is present continuously or long term. Zone 1 A hazardous explosive atmosphere can be expected to occur occasionally. Zone 2 A hazardous explosive atmosphere can be expected to occur only rarely and, if any, short term. Combustible dusts Zone 20 includes areas in which there is a permanent, longterm or frequent explosive atmosphere consisting of dust-air mixtures. Zone 21 includes areas in which an explosive atmosphere consisting of dust-air mixtures can be expected to occur occasionally and short term. Zone 22 includes areas in which an explosive atmosphere cannot be expected to occur due to disturbance of deposited dust. If an explosive atmosphere should nevertheless occur, this will most probably happen only rarely and short term. Directive 94/9/EG The new Directive 94/9/EC specifies the requirements for all devices and protection systems for use in explosion-prone areas. Over and above this, this Directive now directly includes the basic safety requirements for explosion-proof equipment. Manufacturers of explosion-proof equipment have to provide evidence of a quality assurance system to be tested by a notified body. Directive 99/92 EG (Workplace Directive) Also new is the description of hazard areas in explosion-prone workplaces, and a resulting graded safety profile for the equipment used. As this Directive was drafted according to the ECs new approach, the manufacturers declaration of conformity, combined with CE marking of the products, was introduced for explosion-proof equipment as well. A detailed commentary
8 / Chapter 7
on Directive 94/9/EC is included in the Directive 94/9/EC by the European Parliament and the Council of 23 March 1994 section. Since 1 July 2003, it has superseded all directives on explosion protection previously effective at European level. Please note: The previous standard on construction and testing of explosion-proof equipment for Zone 2 has been superseded by ILC 60079-15/EN 60079-15, which specifies higher requirements for Zone 2 luminaires (higher requirements in terms of electronic ballasts and impact resistance).
Yes
Electrical appliance
EC type examination
Documentation of manufacturer
Basic safety and health requirements Classification of max. surface temperatures in electrical equipment of Class 2
Temperature class T1 T2 T3 T4 T5 T6 Max. permissible surface temperature of equipment in C 450 300 200 135 100 85 Ignition temperatures of flammable substances in C > 450 > 300 450 > 300 200 > 200 135 > 100 135 > 85 100
Chapter 7 / 9
10 / Chapter 7
Clean-room technology
Clean-room compatibility tested CLEAN Advanced and CLEAN Supreme have been tested and assessed by the Fraunhofer Institute in Stuttgart (Germany) with respect to clean-room compatibility for clean-rooms (particle emission behaviour of the luminaires) and cleanliness compatibility (disinfectability, electrostatic behaviour and chemical resistance).
Details on clean-room compatibility The German VDI 2083 Guideline specifies a standardised procedure for all equipment used in a clean-room. The common criterion for the clean-room compatibility of luminaires and all other equipment is their particle emission behaviour. Airborne particle emission is used as a classification criterion in all international standards. The relevant maximum value for the permissible concentration of particles of a specific particle size constitutes the class limit. Test setup A defined volume of air is aspirated by an air sampling probe and fed into a test chamber. The particles inside this test chamber are monitored and recorded appropriately. Exceeding the relevant limit values is decisive in order to classify the luminaires. If a limit value is not exceeded with a certainty of at least 95 %, the respective item of equipment may be regarded as suitable for use in this air cleanliness class.
Chapter 7 / 11
Details on cleanliness compatibility In order to be able to confirm cleanliness compatibility as well as quantities reflecting clean-room compatibility that can be detected by metrological methods, additional expert assessments and parameters were included in the tests conducted by the Fraunhofer Institute IPA. Cleanliness compatibility covers a large number of sector-based cleanliness requirements such as resistance to chemicals, surface quality, flow behaviour or electrostatic charge characteristics. These are defined in the following standards and codes of practice, among others: Standardisation General: classification of air cleanliness clean-rooms and associated controlled environments according to DIN EN ISO 14644-1 (Federal Standard 209 has been withdrawn) clean-room technology and clean-room compatibility of equipment VDI 2083 EHEDG (European Hygienic Engineering & Design Group) Industrial application areas: GMP Guidelines (Good Manufacturing Practice) pharmaceuticals FDA (Food and Drug Administration) pharmaceuticals and foodstuffs Medicinal Product Law EU Pharmaceutical Regulation Good manufacturing practices Volume 4 (Medicinal products for human and veterinary use) Hazard Analytical Control Point (HACCP) Regulations foodstuffs Hospital application areas: VDI 2167 Building services in hospitals DIN 1946-4 Ventilation and air conditioning Part 4 (Ventilation in hospitals)
12 / Chapter 7
Airflow systems in clean-rooms One of the basic criteria for the requirements placed on equipment in clean-rooms is the nature of the airflow system. The CLEAN clean-room luminaire has been designed for use in all clean-room classes with a turbulent mixed airflow. In this commonly encountered airflow system, air enters the room with a turbulent flow, thereby causing continuous dilution and cleaning. According to GMP (Good Manufacturing Practice) classification, clean-room Classes C to E and ISO Classes 6 to 9 can be achieved using this airflow system. Clean-rooms with low-turbulence displacement flow, which are more expensive to build, allow air to initially enter the cleanroom with low turbulence. The design of laminar flow cleanrooms precludes the use of any luminaires other than extremely slim batten luminaires which disrupt the directional flow of air as little as possible. The laminar flow system minimises contamination, and any contaminant is quickly eliminated. Cleanrooms in ISO Classes 1 to 6 and GMP Classes A and B are areas where this airflow system is used.
Chapter 7 / 13
14 / Chapter 7
Acetic acid up to 5 % Acetic acid up to 30 % Acetone Alcohol up to 30 % Alcohol, concentrated Aliphatic hydrocarbons Ammonia 25 % Aniline Aromatic hydrocarbons Battery acid Beer Benzene Blood Bromic acid Carbon dioxide Carbon monoxide Carbon tetrachloride Caustic soda solution 2 % Caustic soda solution 10 % Chloroform Chlorophenol Diesel oil, crude oil Dioxan Ether Ethyl acetate (ester) Glycerine Glycol Glysantin Hydrochloric acid up to 20 % above 20 % Hydrogen peroxide up to 40 % over 40 %
Chapter 7 / 15
Ketones Lime milk Lysol Methylene chloride Methanol Metal salts and their aqueous solutions Naphtha (cleaners naphtha) Petrolium ether Pyridine Phenol Nitric acid up to 10 % up to 20 % above 20 % Sea water Soap-suds Soda Sodium chloride solution Sulphuretted hydrogen Sulphuric acid up to 50 % up to 70 % above 70 % Sulphurous acid up to 5 % Synthetic detergents Turpentine Water up to 60 C Xylene
16 / Chapter 7
Maximum number of fluorescent lamps per miniature circuit breaker Number of fluorescent lamps with conventional or low-loss ballast for different lamp circuits
C10 C16 n.k./p.k. n.k./p.k. 1/18 W T26 44/53 73/86 1/3638 W T26 38/53 63/86 1/58 W T26 25/34 40/56 1/57 W TC-S 83/135 136/221 1/9 W TC-S 93/135 153/221 1/11 W TC-S 104/135 170/221 1/1013 W TC-D 72/122 119/200 1/18 W TC-D/-T 62/91 102/149 1/26 W TC-D/-T 43/68 71/112 1/18 W TC-L/-F 44/53 73/86 1/24 W TC-L/-F 41/53 68/86 1/36 W TC-L/-F 38/53 62/86 n. k. = no p.f. correction (inductive) B10 B16 B20 n.k./p.k. n.k./p.k. n.k./p.k. 27/32 43/51 53/63 23/32 37/51 46/63 15/20 24/33 30/41 50/81 80/130 100/162 56/81 90/130 112/162 63/81 100/130 125/162 44/74 70/118 87/147 37/55 60/88 75/110 26/41 42/66 52/82 27/32 43/51 53/63 25/32 40/51 50/63 23/32 37/51 46/63 p. k. = shunt p.f. correction
Loading of automatic circuit breakers for metal halide lamps Maximum recommended number of electronic ballasts per automatic circuit breaker Electronic ballasts for metal halide lamps, non-dimmable (TRIDONIC PCI series, except for PCI ... A101/A201/A202)
C10 1.5 mm 2 30 14 14 7 10 7 C13 1.5 mm2 40 25 25 14 18 14 C16 1.5 mm 2 50 36 36 20 26 20 C20 2.5 mm2 60 42 42 20 30 20 B10 1.5 mm2 15 8 8 4 6 4 B13 1.5 mm2 20 14 14 6 10 6 B16 1.5 mm2 25 18 18 7 13 7 B20 2.5 mm2 30 18 18 7 13 7
Chapter 7 / 17
Loading of automatic circuit breakers for electronic ballasts for fluorescent and compact fluorescent lamps Maximum recommended number of electronic ballasts per automatic circuit breaker Electronic ballasts for T16 fluorescent lamps, non-dimming (TRIDONIC PC T5 PRO lp series)
C10 C13 C16 C20 B10 B13 B16 B20 1.5 1.5 1.5 2.5 1.5 1.5 1.5 2.5 mm 2 mm 2 mm2 mm2 mm2 mm2 mm2 mm 2 1x14/21/28/35 W T16 28 40 44 58 14 20 22 29 2x14/21/28/35 W T16 18 24 28 34 9 12 14 17 3/14 W T16 26 38 44 64 13 19 22 32 4/14 W T16 26 38 44 64 13 19 22 32 1/24 W T16 28 40 44 58 14 20 22 29 2/24 W T16 28 40 44 58 14 20 22 29 3/24 W T16 14 18 22 28 7 9 11 14 4/24 W T16 14 18 22 28 7 9 11 14 1/39 W T16 28 40 44 58 14 20 22 29 2/39 W T16 18 28 30 36 9 14 15 18 1/49 W T16 28 40 44 58 14 20 22 29 2/49 W T16 18 28 30 36 9 14 15 18 1/54 W T16 28 40 44 58 14 20 22 29 2/54 W T16 14 20 24 30 7 10 12 15 1/80 W T16 18 28 30 36 9 14 15 22 2/80 W T16 8 14 16 20 4 7 8 10
Electronic ballasts for T26 fluorescent lamps, non-dimming (TRIDONIC PC T8 PRO series)
C10 1.5 mm 2 44 36 40 30 40 22 38 24 18 36 16 36 16 C13 1.5 mm2 62 50 60 40 52 30 52 32 24 50 22 50 22 C16 1.5 mm2 74 60 80 52 60 38 60 38 32 60 26 60 26 C20 2.5 mm2 104 72 92 64 72 42 72 44 40 70 30 70 30 B10 1.5 mm2 22 18 20 15 19 11 19 12 9 18 8 18 8 B13 1.5 mm2 31 25 30 20 26 15 26 16 12 25 11 25 11 B16 1.5 mm2 37 30 40 26 30 19 30 19 16 30 13 30 13 B20 2.5 mm2 52 36 46 32 36 21 36 22 20 35 15 35 15
18 / Chapter 7
1/18 W 2/18 W 3/18 W 4/18 W 1/30 W 2/30 W 1/36 W 2/36 W 3/36 W 1/58 W 2/58 W 1/70 W 2/70 W
T26 T26 T26 T26 T26 T26 T26 T26 T26 T26 T26 T26 T26
Electronic ballasts for T16 fluorescent lamps, dimmable (TRIDONIC PCA T5 ECO/EXCEL one4all (lp) series)
C10 1.5 mm 2 50 38 16 16 50 30 38 24 34 16 50 24 34 16 24 12 24 12 14 10 C13 1.5 mm2 80 54 26 24 80 40 54 34 50 22 80 34 50 22 34 18 34 18 20 14 C16 1.5 mm2 150 78 34 34 120 60 78 48 76 30 150 48 70 30 48 26 48 26 28 20 C20 2.5 mm2 180 92 42 38 150 64 92 52 86 32 180 52 86 32 52 26 52 26 28 22 B10 1.5 mm2 25 19 8 8 25 15 19 12 17 8 25 12 17 8 12 6 12 6 7 5 B13 1.5 mm2 40 27 13 12 40 20 27 17 25 11 40 17 25 11 17 9 17 9 10 7 B16 1.5 mm2 75 39 17 17 60 30 39 24 38 15 75 24 38 15 24 13 24 13 14 10 B20 2.5 mm2 90 46 21 19 75 32 46 26 43 16 90 26 43 16 26 13 26 13 14 11
1/14 W 2/14 W 3/14 W 4/14 W 1/21 W 2/21 W 1/28 W 2/28 W 1/35 W 2/35 W 1/24 W 2/24 W 1/39 W 2/39 W 1/49 W 2/49 W 1/54 W 2/54 W 1/80 W 2/80 W
T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16 T16
Electronic ballasts for T26 fluorescent lamps, dimmable (TRIDONIC PCA T8 ECO/EXCEL one4all series)
C10 1.5 mm 2 30 20 16 12 30 10 30 10 30 10 20 10 C13 1.5 mm2 50 30 18 16 50 20 50 20 50 20 30 20 C16 1.5 mm2 76 40 24 24 70 30 70 30 70 30 40 30 C20 2.5 mm2 80 46 30 28 76 30 76 30 76 30 46 30 B10 1.5 mm2 15 10 8 6 15 5 15 5 15 5 10 5 B13 1.5 mm2 25 15 9 8 25 10 25 10 25 10 15 10 B16 1.5 mm2 38 20 12 12 35 15 35 15 35 15 20 15 B20 2.5 mm2 40 23 15 14 38 15 38 15 38 15 23 15
1/18 W 2/18 W 3/18 W 4/18 W 1/30 W 2/30 W 1/36 W 2/36 W 1/38 W 2/38 W 1/58 W 2/58 W
T26 T26 T26 T26 T26 T26 T26 T26 T26 T26 T26 T26
Chapter 7 / 19
Electronic ballasts for TC-L fluorescent lamps, non-dimmable (TRIDONIC PC TCL PRO series)
C10 1.5 mm2 30 24 30 24 38 24 38 14 28 8 C13 1.5 mm2 40 32 40 32 54 34 54 24 38 14 C16 1.5 mm2 48 38 48 38 76 44 78 28 50 18 C20 2.5 mm2 60 46 60 46 90 50 90 34 60 20 B10 1.5 mm2 15 12 15 12 19 12 19 7 14 4 B13 1.5 mm2 20 16 20 16 27 17 27 12 19 7 B16 1.5 mm2 24 19 24 19 38 22 39 14 25 9 B20 2.5 mm2 30 23 30 23 45 25 45 17 30 10
1/18 W 2/18 W 1/24 W 2/24 W 1/36 W 2/36 W 1/40 W 2/40 W 1/55 W 2/55 W
TC-L TC-L TC-L TC-L TC-L TC-L TC-L TC-L TC-L TC-L
Electronic ballasts for TC-L compact fluorescent lamps, Basic dimming/Dali dimming (TRIDONIC PCA TCL ECO/EXCEL one4all series)
C10 1.5 mm2 10 16 30 10 30 10 20 10 10 C13 1.5 mm2 12 20 50 20 50 20 30 14 20 C16 1.5 mm2 16 24 70 30 70 30 40 18 30 C20 2.5 mm2 20 30 76 30 76 30 46 20 30 B10 1.5 mm2 5 8 15 5 15 5 10 5 5 B13 1.5 mm2 6 10 25 10 25 10 15 7 10 B16 1.5 mm2 8 12 35 15 35 15 20 9 15 B20 2.5 mm2 10 15 38 15 38 15 23 10 15
20 / Chapter 7
Electronic ballasts for TC-DEL/TEL fluorescent lamps, nondimmable (TRIDONIC PC PRO series)
C10 1.5 mm 2 48 32 46 32 48 32 46 32 48 48 34 22 34 22/14 34 14 C13 1.5 mm2 72 44 70 44 72 44 70 44 72 72 46 32 46 32/18 46 18 C16 1.5 mm2 80 54 78 52 80 54 78 52 80 80 74 38 74 38/22 74 22 C20 B10 2.5 1.5 mm2 mm2 100 24 64 16 98 23 60 16 100 24 64 16 98 23 60 16 100 24 100 24 84 17 44 11 84 17 44/30 11/7 84 17 30 7 B13 B16 B20 1.5 1.5 2.5 mm2 mm2 mm2 36 40 50 22 27 32 35 39 49 22 26 30 36 40 50 22 27 32 35 39 49 22 26 30 36 40 50 36 40 50 23 37 42 16 19 22 23 37 42 16/9 19/11 22/15 23 37 42 9 11 15
1/9 W TC-SEL 2/9 W TC-SEL 1/10 W TC-DEL 2/10 W TC-DEL 1/11 W TC-SEL 2/11 W TC-SEL 1/13 W TC-DEL/TC-TEL 2/13 W TC-DEL/TC-TEL 1/18 W TC-DEL/TC-TEL 2/18 W TC-DEL/TC-TEL 1/26 W TC-DEL/TC-TEL 2/26 W TC-DEL/TC-TEL 1/32 W TC-DEL/TC-TEL 2/32 W TC-DEL/TC-TEL 1/42 W TC-DEL/TC-TEL 2/42 W TC-DEL/TC-TEL
Electronic ballasts for TC-DEL/TEL compact fluorescent lamps, Basic dimming/Dali dimming (TRIDONIC PCA TCD/TCT ECO/EXCEL one4all series)
C10 C13 1.5 1.5 mm 2 mm2 40 60 28 40 40 60 28 40 30 50 22 32 30 50 22 32 26 38 10 18 26 38 12 18 12 16 C16 C20 1.5 2.5 mm2 mm2 80 80 60 64 80 80 60 64 70 76 46 68 70 76 46 56 50 58 24 28 50 58 24 28 22 26 B10 1.5 mm2 20 14 20 14 15 11 15 11 13 5 13 6 6 B13 1.5 mm2 30 20 30 20 25 15 25 16 19 9 19 9 8 B16 1.5 mm2 40 30 40 30 35 23 35 23 25 12 25 12 11 B20 2.5 mm2 40 32 40 32 38 34 38 28 29 14 29 14 13
1/11 W TC-SEL 2/11 W TC-SEL 1/13 W TC-DEL 2/13 W TC-DEL 1/18 W TC-DEL/TC-TEL 2/18 W TC-DEL/TC-TEL 1/26 W TC-DEL/TC-TEL 2/26 W TC-DEL/TC-TEL 1/32 W TC-DEL/TC-TEL 2/32 W TC-DEL/TC-TEL 1/42 W TC-DEL/TC-TEL 2/42 W TC-DEL/TC-TEL 1/57 W TC-TEL The Lighting Handbook
Chapter 7 / 21
Loading of automatic circuit breakers for high-pressure lamps Maximum recommended number of ballasts per automatic circuit breaker Conventional ballasts for metal halide lamps, uncompensated
Lamp W 35 70 150 250 400 400 values A 0.53 0.98 1.8 3 3.5* 4.4** Number of ballasts per automatic circuit breaker C10 C16 C20 C25 B10 B16 B20 B25 11 18 23 29 9 15 18 23 7 11 14 17 5 8 9 12 4 6 7 9 2 4 5 6 2 3 4 5 1 2 3 4 2 3 4 5 1 2 2 3 1 2 3 4 1 1 2 2
* with OGLI 400 ... ballast and lamp current of approx. 3.5 A ** with OGLS 400 ... ballast and lamp current of approx. 4.4 A
22 / Chapter 7
B25 27 20 12 8 6 5
* with OGLI 400 ... ballast and lamp current of approx. 3.5 A ** with OGLS 400 ... ballast and lamp current of approx. 4.4 A
B25 27 20 17 12 8 5
Chapter 7 / 23
Loading of automatic circuit breakers for low-voltage halogen incandescent lamps Maximum recommended number of transformers per automatic circuit breaker Magnetic transformers for QT/QR/QR-CB(C) halogen incandescent lamps (TRIDONIC TMBx/OMTx series)
Power 20 W 35 W 50 W 70 W 80 W 105 W 150 W 210 W 300 W C10 58 41 21 15 14 8 4 23 12 C16 93 65 35 24 22 13 6 45 23 B10 29 20 10 7 7 4 2 1 n.r. B16 46 32 17 12 11 6 3 2 1
Magnetic transformers for QT/QR/QR-CB(C) halogen incandescent lamps (TRIDONIC TMAx/TMDx series)
Power 20 W 35 W 40 W 50 W 60 W 70 W 80 W 105 W C10 42 35 26 23 21 16 13 9 C16 67 56 43 37 33 26 21 14 B10 21 17 13 11 10 8 6 4 B16 33 28 21 18 16 13 10 7
Magnetic transformers for QT/QR/QR-CB(C) halogen incandescent lamps (TRIDONIC OGT series)
Power 250 W 300 W 500 W C10 34 2 1 C16 56 34 12 B10 12 1 n.r. B16 23 12 n.r.
24 / Chapter 7
Low-voltage installation
Service life and luminous flux The service life and luminous flux of low-voltage halogen lamps are extremely voltage dependent. Voltage changes on the line side are transferred to the secondary side in the same ratio.
50
30 20 10 8 6 4 2
Lh
1=
100% 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.15 60 % 80 % 100 % 120 %
A 1 V overvoltage is insignificant for a 230 W halogen 4 lamp. For a 12 V halogen lamp, 3 however, this represents an 2 overvoltage of 8 % which re1 = duces the average 100 % service life of the 0.8 0.6 halogen lamp, e.g. 0.4 from 3,000 hours 0.3 to approx. 1,200 0.2 hours.
7 6 5 0.1 0.08 0.06 0.04 0.03 0.02
Lh
140 %
Operation at rated load Magnetic transformers should be operated at rated load as far as possible so as to avoid any rise in the secondary voltage which can result in a reduction in lamp service life (5 % overvoltage corresponds to 30 % shorter life). Conductor cross-sections and voltage drop Because the voltages are small, large currents flow on the secondary side. If conductors are long and have small crosssections, this can result in considerable voltage drops. Crosssections must be chosen so that the voltage drop across the conductor between transformer and lamp does not exceed 5 %.
The Lighting Handbook
Chapter 7 / 25
Required conductor cross-sections in mm2 as a function of transformer rating and cable length (one-way line length) for magnetic transformers:
Transformer rating Cable length in m
up to 6 m 1.5 1.5 4 6 6
up to 8 m 1.5 2.5 4 6 10
Installation The distance between transformer and lamps must be as short as possible (minimum distance, however, is approx. 30 cm) in order to avoid the relatively large conductor cross-sections. On the other hand, there is often unwanted humming, especially when lighting is adjusted; therefore the transformer must be installed out of earshot if possible.
Transformer
Wherever possible, cables must be laid in a star configuration and be of equal length to ensure that all lamps receive the same voltage.
26 / Chapter 7
Transformers and light regulation Only approved safety transformers should be used. The ambient temperature must not exceed 50 C max. Please note that transformers for use in areas which present fire risks must carry the appropriate conformity mark (e.g. , , , ). Phase control Halogen lamps are operated with a magnetic transformer. Reverse phase control Halogen lamps are operated with an electronic transformer in the high-frequency range. Important: do not exceed maximum conductor length. Safety measures when operating low-voltage halogen lamps Low-voltage halogen lamps generate a huge amount of heat. In the case of recessed luminaires, make sure there is adequate heat removal and that the safety distances from combustible materials are observed. The necessary safety distances from the illuminated surface also apply when using spotlights. These are identified by the following symbol and details of the relevant distance in metres:
Chapter 7 / 27
Chapter 8
Checklists
The five steps of lighting design . . . . . . . . . . . . . . . . . Checklist according to the five steps of lighting design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance of lighting systems . . . . . . . . . . . . . . . . . Environmental conditions . . . . . . . . . . . . . . . . . . . . . Lamp lumens maintenance factor (LLMF) and lamp survival factor (LSF) . . . . . . . . . . . . . . . . . Table for luminaire maintenance factor (LMF) . . . . . . Table for room surface maintenance factor (RSMF) . . . Economic efficiency calculation . . . . . . . . . . . . . . . . . . Economic analysis . . . . . . . . . . . . . . . . . . . . . . . . . . Table of burning hours . . . . . . . . . . . . . . . . . . . . . . . Refurbishment of lighting systems . . . . . . . . . . . . . . . . Data collection sheet for lighting refurbishment . . . . . Analysis of malfunctions in luminaires . . . . . . . . . . . . . 3 11 4 11 12 19 13 14 17 18 19 20 23 21 22 23 24 28 27 28 29 33
The five steps of lighting design = help for structuring the lighting design scheme Determine lighting REQUIREMENTS SELECT lamps, luminaires and lighting management Calculate NUMBER of luminaires required POSITION luminaires and lighting control ANALYSE the results
From experience we know that usually Step 1 = Determine lighting requirements is not taken into account sufficiently. The checklist below should help the user to consider key questions for clarifying basic requirements. Accordingly, requirements are broken down as follows: general conditions lighting quality requirements visual performance vista visual comfort vitality empowerment The lighting quality criteria are in line with those set by the EU. ELI (Ergonomic Lighting Indicator) was developed in collaboration with ETH Zurich and TU Ilmenau (Prof. Dr. Schierz). Understanding this task will allow for proper development of a well thought-out lighting solution based on the quality characteristics of lighting (Chapter 1) and project-specific requirements. Analysis includes the assessment of lighting quality. In the process, the requirement criteria are taken into account. The formulations for assessment differ from the requirements (ELI assessment).
The Lighting Handbook
Chapter 8 / 3
Checked
At the workstations, ... standard visual tasks have to be performed. ... visual tasks are the same across the whole area. ... colour distinction is required to a common extent. ... no extraordinary changes of viewing direction occur. 4 / Chapter 8
-2 -1 0* 1 2 -2 -1 0 1 2
-2 -1 0 1 2 -2 -1 0 1 2
Within the visual task area, ... hard shadows must be avoided. ... the field of vision should be free from sources of glare. ... reflections must be avoided.
* Minimum criterion, corresponds to values specified in the standards -2 -1 0 1 2 -2 -1 0 1 2 -2 -1 0 1 2 Mean value Visual task
Criterion B Vista
How do you want to experience the lighting solution in your environment? Explanation: In prestigious buildings, for example, light is not only needed for seeing but also enhances the looks of the interior. Light can provide guidance and create a favourable first visual impression of a room.
In the project planned, ... ... the lighting concept should blend in smoothly with the interior design. ... the lighting concept should be properly geared towards expectations. ... the lighting concept should facilitate orientation in the room. In the project planned, ... ... the first visual impression will be decisive. ... the perceptible quality of the luminaire will be of major importance. ... the cleanliness of the room and the lighting will be of major importance.
1 = does not apply at all; 5 = applies completely 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
In the project planned, ... ... users must be particularly protected from annoying sources of glare.
The Lighting Handbook
-2 -1 0 * 1 2
... it will be particularly important to identify three-dimensional structures in the room. ... the room should provide a bright and inviting impression.
-2 -1 0 1 2
-2 -1 0 1 2
Chapter 8 / 5
... daylight must be taken into account. ... there must be no flickering light. ... larger dark areas should be avoided. In the area around the visual task, the room should be illuminated uniformly.
* Minimum criterion, corresponds to values specified in the standards
-2 -1 0 1 2 -2 -1 0 1 2 -2 -1 0 1 2 -2 -1 0 1 2
Criterion D Vitality
How positive should the lights influence be on people? Explanation: Light significantly influences peoples activity and sense of well-being. Moreover, it has a positive impact on their health and may even enhance or influence biological processes.
The lighting concept ... should make people feel good. ... should stimulate people. In the project planned, ... ... it should be possible in particular to adjust the lighting to the brightness level required. ... the effect to be created should be as natural as possible. ... peoples circadian rhythm should be particularly taken into account. In the project planned, special emphasis is put on protection against sources of annoyance or adverse health effects.
1 = does not apply at all; 5 = applies completely 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
Criterion E Empowerment
To what extent should the lighting adjust to my personal requirements? Explanation: Varying visual requirements, visual tasks or periods of use call for options to individually influence ones lighting situation. Sensors and control systems help users adjust the lighting situation to their personal needs.
In the project planned, ... ... the user should be able to personally influence the lighting situation. ... a variety of tasks must be taken into account. The lighting should be switched automatically. The artificial lighting should be controlled by daylight sensors. 6 / Chapter 8
1 2 3 4 5
1 2 3 4 5 1 2 3 4 5
1 2 3 4 5
The lighting should be controlled on the basis of time. Any future layout changes should be taken into account.
1 = does not apply at all; 5 = applies completely
1 2 3 4 5 1 2 3 4 5
Visual performance
1 0 5
E
Empowerment
-1 2 1 -2 1 1 2 -2 -1 0 1 2 2 3
5B Vista
3 4 5
D
Vitality
C
Visual comfort
ELI
60
120
0
kWh/m2 a
180
Chapter 8 / 7
2. Selection of lamps, luminaires and lighting management Lamp type Luminaire range and model Lighting management range and modules 3. Calculate number of luminaires required Rough calculation (Quickplan/Quickcalc) Detailed calculation (Dialux/Relux) Planning conditions (maintenance, reflection) 4. Positioning of luminaires and lighting control Positioning the luminaires structural situation orientation (avoid reflections and glare) spacings between luminaires (regular patterns) peripheries alignment techn. infrastructure (distribution cabinet, clamping compartment, ) Position of control gear Emergency lighting 5. Analysis of results Lighting quality analysis (ELI assessment) Criterion A Visual performance
How well can the visual task be recognised?
Checked
Explanation: Lighting in conformity with relevant standards is decisive for ensuring that the visual task can be identified and the related activities can be carried out. Consideration of the traditional quality characteristics of lighting has a major impact on visual task performance.
In the main visual task area, the lighting ... provides uniformity of illuminance. ... complies with the colour rendition index. 8 / Chapter 8
-2 -1 0 1 2 -2 -1 0 1 2
-2 -1 0 * 1 2
In the area around the visual task, the illuminance level required is achieved. In the lighting installation as it exists at present, ... annoying hard shadows, ... irritating direct glare ... and annoying reflections are avoided.
* Minimum criterion, corresponds to values specified in the standards
-2 -1 0 1 2
Please note: EN 12464 specifies standard values; values may be lower only if visual tasks are modified. Where there are several task areas, calculate and assess the mean value for all of them.
Criterion B Vista
How do you experience the lighting solution in your environment? Explanation: In prestigious buildings, for example, light is not only needed for seeing but also enhances the looks of the interior. Light can provide guidance and create a favourable first visual impression of a room.
The lighting concept ... enhances interior design features. ... fulfils my personal expectations. ... takes passageways, circulation areas and activity zones into consideration. ... creates a hierarchy of perception (lighting focuses). The luminaires make a high-quality impression. The luminaires are neither soiled nor affected by other foreign substances.
1 = does not apply at all; 5 = applies completely 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
The lighting components are balanced and matched to the room. The ceiling and walls are pleasantly bright.
-2 -1 0 1 2
-2 -1 0 1 2
Chapter 8 / 9
The lighting solution ... takes daylight into account and uses it. ... does not flicker. ... does not allow major dark areas in the room. The task area environment is uniformly illuminated.
* Minimum criterion, corresponds to values specified in the standards -2 -1 0 1 2 -2 -1 0 1 2 -2 -1 0 1 2 -2 -1 0 1 2
Criterion D Vitality
How positive is the lights influence on the people? Explanation: Light significantly influences peoples activity and sense of well-being. Moreover, it has a positive impact on their health and may even enhance or influence biological processes.
The lighting ... is one of the factors that make me feel good. ... has a stimulating effect. ... adjusts to the brightness level required. The lighting creates a natural, pleasant effect. The lighting stabilises/enhances the users circadian rhythm. There are no sources of annoyance or adverse health effects.
1 = does not apply at all; 5 = applies completely 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
1 2 3 4 5
Criterion E Empowerment
To what extent does the lighting adjust to my personal requirements? Explanation: Varying visual requirements, visual tasks or periods of use call for options to individually influence ones lighting situation. Sensors and control systems help users adjust the lighting situation to their personal needs. 1 2 3 4 5
The installation can be switched or dimmed. A variety of lighting scenes can be called up.
1 2 3 4 5 1 2 3 4 5
Presence detectors make sure that the lighting switches automatically. Thanks to daylight sensors, the artificial lighting adjusts to daylight changes over the course of the day. Automated, dynamic scenes are available. 10 / Chapter 8
1 2 3 4 5
1 2 3 4 5
Luminaires and switches can be rearranged flexibly. The luminaires are arranged so as to allow for flexible change in room utilisation without major effort.
1 = does not apply at all; 5 = applies completely
1 2 3 4 5 1 2 3 4 5
1 0 5
E
Empowerment
-1 2 1 -2 1 1 2 -2 -1 0 1 2 2 3
5B Vista
3 4 5
D
Vitality
C
Visual comfort
ELI 60 120
0
kWh/m2 a
180
LENI Calculation see Chapter 1 / 19 Other analyses Situation regarding standards Economic efficiency
The Lighting Handbook
Please note: at a lower maintenance factor, illuminance may be constantly dimmed to the maintenance value to save energy (maintenance control). The maintenance factor includes 4 components: (2) MF = LLMF x LSF x LMF x RMF All these factors describe the decrease in illuminance. The maximum in each case is 1, corresponding to the new value. At the respective time of maintenance, the various causes of the decrease in illuminance must be identified.
Maintenance factor components Causes of illuminance decrease
Lamp luminous flux mainten. factor LLMF Lamp survival factor LSF Luminaire maintenance factor LMF Room maintenance factor RMF
12 / Chapter 8
Options for improving the maintenance factor: lamp replacement already before the lamp service life ends (LLMF/LSF ) immediate replacement of lamps in case of failure (LSF = 1) use of closed luminaires (LWF7 ) more frequent room cleaning (RWF7 )
160 % 140 % 120 % 100 % 80 % 60 % 40 % 20 % 0.0 0.5 1.0 1.5 2.0 years 2.5 3.0
Example: Luminaire maintenance: every year Room surface maintenance: every 3 years Lamp replacement: every 3 years Faulty lamp replacement: immediately
= E new = Em 3.5
Environmental conditions
In case you are not familiar with the application, the following standard values apply; however, the tables below will help you calculate the accurate maintenance factor according to formula (2).
Ambient condition Very Clean (SS) Maintenance Working interval areas recommended 3 years Clean-rooms, data centres, assembly workstations for electronic components 3 years 2 years Offices, schools Shops, laboratories, restaurants, warehouses, assembly bays Steel works, chemical plants, foundries, welding shops, grinding shops, wood processing Reference maintenance factor 0.80
0.67 0.57
Soiled (V)
1 year
0.50
According to CIE volume 97, Maintenance of indoor electric lighting systems, at 2005
Chapter 8 / 13
14 / Chapter 8
Lamps
Incandescent lamp CIE97:2005 Halogen incandescent lamp CIE97:2005 T26 (low-loss ballast) single-band fluorescent lamp ZVEI 2005 T26 (low-loss ballast) triple-band fluorescent lamp ZVEI 2005 T26 (electronic ballast) triple-band fluor. lamp ZVEI 2005/CIE97:2005 T26 (el. ball.) triple-band fluor. lamp, long-life Philips MASTER TL-D Xtreme (long life) T26 (el. ball.) triple-band fluor. lamp, long-life AURA Ultimate LL (long life) T16 (electronic ballast) triple-band fluorescent lamp ZVEI 2005 T16 (el. ball.) triple-band fluor. lamp, long-life AURA SUPREME T5 HO LL (long life)
LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF
Burning hours 100 500 1,000 1,500 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 30,000 35,000 40,000 45,000 1.00 0.97 0.93 1.00 0.98 0.50 1.00 0.99 0.97 0.95 1.00 1.00 0.78 0.50 1.00 0.97 0.94 0.91 0.89 0.82 0.78 0.76 0.73 0.72 1.00 1.00 0.99 0.99 0.98 0.96 0.94 0.90 0.78 0.60 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.92 0.91 1.00 1.00 0.99 0.99 0.98 0.98 0.97 0.95 0.93 0.83 0.60 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.92 0.91 0.90 0.90 0.90 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.98 0.98 0.97 0.95 0.90 0.75 0.50 1.00 0.99 0.99 0.98 0.98 0.98 0.97 0.96 0.95 0.95 0.94 0.94 0.93 0.93 0.93 0.92 0.91 0.90 0.90 0.90 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.90 0.70 1.00 1.00 1.00 1.00 0.98 0.98 0.97 0.97 0.97 0.96 0.95 0.95 0.94 0.94 0.94 0.93 0.92 0.91 0.91 0.91 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 0.99 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.92 0.91 0.90 0.90 0.90 0.90 0.89 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.98 0.98 0.98 0.97 0.97 0.96 0.91 0.80 0.50 1.00 1.00 0.99 0.99 0.98 0.96 0.95 0.94 0.93 0.92 0.91 0.90 0.90 0.90 0.90 0.89 0.89 0.88 0.88 0.88 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 0.98 0.98 0.98
Compact fluorescent lamp CIE97:2005 TC-S, TC-D, TC-T 5-26W (low-loss ballast) Compact fluor. lamp ZVEI 2005 TC-SEL, TC-TEL 5-42W (electronic ballast) Compact fluor. lamp ZVEI 2005 TC-DEL 10-26W (electronic ballast) Compact fluor. lamp ZVEI 2005 TC-L 18-36W (low-loss ballast) Compact fluor. lamp ZVEI 2005 TC-L 18-80W (electronic ballast) Compact fluor. lamp ZVEI 2005 Induction lamp Philips QL
LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF
1.00 0.98 0.97 0.94 0.91 0.89 0.87 0.85 1.00 0.99 0.99 0.98 0.97 0.94 0.86 0.50 1.00 0.98 0.97 0.95 0.93 0.86 0.83 0.80 0.78 1.00 1.00 1.00 0.99 0.98 0.97 0.95 0.81 0.60 1.00 0.98 0.96 0.94 0.93 0.87 0.84 0.82 0.80 0.79 1.00 1.00 0.99 0.99 0.99 0.98 0.97 0.93 0.76 0.55 1.00 0.98 0.96 0.94 0.92 0.87 0.85 0.82 0.80 0.79 0.78 1.00 1.00 1.00 0.99 0.99 0.98 0.97 0.96 0.91 0.80 0.60 1.00 0.99 0.98 0.97 0.96 0.92 0.90 0.89 0.88 0.88 0.88 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.98 0.95 0.86 0.62 1.00 0.99 0.98 0.97 0.97 0.94 0.93 0.91 0.90 0.90 0.90 0.90 0.90 0.89 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.98 0.98 0.96 0.95 0.90 0.75 0.50 1.00 0.99 0.98 0.97 0.97 0.94 0.92 0.89 0.88 0.87 0.86 0.86 0.85 0.84 0.83 0.83 0.81 0.79 0.77 0.75 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.99 0.98 0.98 0.98 0.97 0.96 0.94
Chapter 8 / 15
Values acc. to specications by lamp manufacturers, January 2008, acc. to CIE97:2005 Technical report Guide on the Maintenance of Indoor Electric Lighting Systems 2nd edition, and ZVEI publication Service life behaviour of discharge lamps for lighting of November 2005. For data of lamps by other manufacturers or other lamp types, please contact the respective manufacturer directly. The use of state-of-the-art ballast technology is a prerequisite. The switching frequency has a major inuence on lamp survival. Most data are based on the standardised 3-hour switching rhythm acc. to IEC (2.75 h ON, 0.25 h OFF).
16 / Chapter 8
Lamps
Metal halide lamp Ceramic (50-150W) CIE97:2005 Metal halide lamp Ceramic Philips CDM-T 70W/Elite Metal halide lamp Ceramic Osram HCI-T 150W/WDL PB Metal halide lamp Ceramic Osram HCI 250W PB Metal halide lamp Quartz (250/400W) CIE97:2005 Metal halide lamp Quartz Osram HQI-E 250W/D Metal halide lamp Quartz Osram HQI-E 400W/D Metal halide lamp Quartz Osram HQI-BT 400W/N Metal halide lamp Quartz Philips HPI-T Plus 250/400W
LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF LLMF LSF
Burning hours 100 500 1,000 1,500 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 30,000 35,000 40,000 45,000 1.00 0.95 0.87 0.75 0.72 0.68 0.64 0.60 0.56 1.00 0.99 0.99 0.98 0.98 0.98 0.95 0.80 0.50 1.00 0.99 0.98 0.96 0.95 0.91 0.87 0.85 0.81 0.80 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.90 0.50 1.00 0.93 0.88 0.87 0.86 0.80 0.77 0.73 0.71 0.69 1.00 1.00 1.00 1.00 0.99 0.99 0.98 0.96 0.88 0.70 1.00 0.96 0.92 0.91 0.90 0.87 0.84 0.81 0.80 0.75 1.00 0.99 0.98 0.98 0.97 0.94 0.90 0.85 0.75 0.62 1.00 0.98 0.95 0.90 0.87 0.83 0.79 0.65 0.63 0.60 0.56 0.53 0.50 1.00 0.99 0.99 0.98 0.97 0.92 0.86 0.80 0.73 0.68 0.63 0.55 0.50 0.99 0.98 0.92 0.88 0.85 0.80 0.75 0.70 0.69 0.65 1.00 0.99 0.98 0.97 0.95 0.91 0.86 0.79 0.70 0.61 1.00 0.97 0.93 0.88 0.85 0.80 0.78 0.74 0.71 0.69 1.00 0.99 0.98 0.97 0.95 0.91 0.86 0.79 0.70 0.61 1.00 0.97 0.92 0.87 0.83 0.77 0.73 0.72 0.70 0.69 1.00 0.99 0.98 0.97 0.95 0.91 0.86 0.79 0.70 0.61 1.00 0.98 0.96 0.93 0.92 0.86 0.83 0.80 0.78 0.76 0.74 0.73 0.72 0.71 1.00 1.00 0.99 0.99 0.99 0.98 0.96 0.93 0.89 0.84 0.75 0.66 0.59 0.50
1.00 0.99 0.98 0.97 0.96 0.91 0.87 0.83 0.81 0.79 0.77 0.75 1.00 0.99 0.98 0.98 0.97 0.96 0.94 0.91 0.84 0.77 0.63 0.50 1.00 0.98 0.94 0.91 0.87 0.80 0.77 0.75 0.73 0.72 0.71 0.70 1.00 1.00 0.99 0.99 0.98 0.97 0.96 0.93 0.88 0.83 0.72 0.50 1.00 0.99 0.98 0.97 0.96 0.93 0.90 0.89 0.88 0.88 0.87 0.87 0.87 0.86 0.85 1.00 1.00 0.99 0.99 0.98 0.97 0.96 0.93 0.92 0.89 0.84 0.79 0.72 0.63 0.50 1.00 0.99 0.98 0.97 0.96 0.93 0.92 0.91 0.90 0.89 0.88 0.88 0.88 0.88 0.87 0.87
High-pressure mercury-vapour lamp 501,000W ZVEI 2005 Mercury vapour lamp Philips HPL-N 50-400W Sodium vapour lamp 50/70W ZVEI 2005 Sodium vapour lamp 150400W (standard luminous flux) ZVEI 2005 Sodium vapour lamp 150400W (higher luminous flux) ZVEI 2005 Sodium vapour lamp Philips SON(-T) PIA Plus 100-400W
LSF 1.00 1.00 0.99 0.98 0.98 0.97 0.97 0.96 0.95 0.93 0.92 0.90 0.88 0.84 0.79 0.70 LLMF 1.00 0.99 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.92 0.91 0.91 0.90 0.90 0.90
LSF 1.00 1.00 1.00 1.00 0.99 0.98 0.98 0.97 0.97 0.95 0.93 0.92 0.90 0.86 0.81 0.73 LLMF 1.00 0.99 0.99 0.98 0.98 0.97 0.97 0.96 0.95 0.95 0.94 0.94 0.93 0.93 0.92 0.92 0.90 0.89 LSF 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.98 0.97 0.96 0.93 0.92 0.88 0.86 0.82 0.77 0.55 0.43
Chapter 8 / 17
Values acc. to specications by lamp manufacturers, January 2008, acc. to CIE97:2005 Technical report Guide on the Maintenance of Indoor Electric Lighting Systems 2nd edition, and ZVEI publication Service life behaviour of discharge lamps for lighting of November 2005. For data of lamps by other manufacturers or other lamp types, please contact the respective manufacturer directly. The use of state-of-the-art ballast technology is a prerequisite. The switching frequency has a major inuence on lamp survival. Most data are based on the standardised 3-hour switching rhythm acc. to IEC (2.75 h ON, 0.25 h OFF).
18 / Chapter 8
V SS S 2.0 N V SS V 2.5 V SS S N 3.0 S N
Luminaire cleaning interval in years Environment type Luminaire type Bare batten luminaires
0.5 SS S N
V SS
1.0 S N
V SS
1.5 S N
0.98 0.95 0.92 0.88 0.96 0.93 0.89 0.83 0.95 0.91 0.87 0.80 0.94 0.89 0.84 0.78 0.93 0.87 0.82 0.75 0.92 0.85 0.79 0.73
0.96 0.95 0.91 0.88 0.95 0.90 0.86 0.83 0.94 0.87 0.83 0.79 0.92 0.84 0.80 0.75 0.91 0.82 0.76 0.71 0.89 0.79 0.74 0.68
0.95 0.93 0.89 0.83 0.94 0.89 0.81 0.72 0.93 0.84 0.74 0.64 0.91 0.80 0.69 0.59 0.89 0.77 0.64 0.54 0.87 0.74 0.61 0.52
Enclosed IP2X
0.94 0.92 0.87 0.83 0.94 0.88 0.82 0.77 0.93 0.85 0.79 0.73 0.91 0.83 0.77 0.71 0.90 0.81 0.75 0.68 0.89 0.79 0.73 0.65
Dust-proof IP5X
0.94 0.96 0.93 0.91 0.96 0.94 0.90 0.86 0.92 0.92 0.88 0.83 0.93 0.91 0.86 0.81 0.92 0.90 0.85 0.80 0.92 0.90 0.84 0.79
0.94 0.92 0.89 0.85 0.93 0.86 0.81 0.74 0.91 0.81 0.73 0.65 0.77 0.88 0.66 0.57 0.86 0.73 0.60 0.51 0.85 0.70 0.55 0.45 Indirect luminaires From CIE publication 97 Maintenance of indoor electric lighting systems, dated 2005, ISBN 3 900 734 34 8 Ambient conditions: SS = very clean (sehr sauber), S = clean (sauber), N = normal, V = soiled (verschmutzt)
5.0
5.5
6.0
Room cleaninginterval in years 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Illumina- Environment tion type type Direct SS 1.00 0.98 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 S 1.00 0.96 0.95 0.94 0.94 0.94 0.94 0.94 0.94 0.94 N 1.00 0.92 0.91 0.90 0.90 0.90 0.90 0.90 0.90 0.90 V 1.00 0.87 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 Direct/ SS 1.00 0.97 0.96 0.95 0.95 0.95 0.95 0.95 0.95 0.95 Indirect S 1.00 0.93 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 N 1.00 0.87 0.84 0.84 0.83 0.83 0.83 0.83 0.83 0.83 V 1.00 0.77 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 Indirect SS 1.00 0.95 0.93 0.92 0.92 0.92 0.92 0.92 0.92 0.92 S 1.00 0.89 0.86 0.85 0.85 0.84 0.84 0.84 0.84 0.84 N 1.00 0.77 0.73 0.72 0.72 0.72 0.72 0.72 0.72 0.72 V 1.00 0.60 0.56 0.55 0.55 0.55 0.55 0.55 0.55 0.55 From CIE publication 97 Maintenance of indoor electric lighting systems, dated 2005, ISBN 3 900 734 34 8 The figures in the table above apply to reflection factors 70/50/20 and a medium-sized room (k = 2.5) Ambient conditions: SS = very clean (sehr sauber), S = clean (sauber), N = normal, V = soiled (verschmutzt) 0.97 0.94 0.90 0.86 0.95 0.91 0.83 0.75 0.92 0.84 0.72 0.55 0.97 0.94 0.90 0.86 0.95 0.91 0.83 0.75 0.92 0.84 0.72 0.55 0.97 0.94 0.90 0.86 0.95 0.91 0.83 0.75 0.92 0.84 0.72 0.55
Chapter 8 / 19
20 / Chapter 8
Definition of terms used in the economic analysis sheets (3) System power of luminaire: Lamp wattage + power dissipation in control gear (5) Annual burning hours: Total of the daily lamp ON hours over the year. The table of burning hours (Chap. 8/23) provides help for daylight-based systems. (9) Maintenance factor: A reference maintenance factor of 0.67 can be assumed (3-year maintenance interval, clean environment), e.g. office; see Chap. 8/12). The maintenance value can be determined precisely on the basis of the details included in the previous chapter Maintenance of lighting installations. The lighting calculation cannot be made until the maintenance factor has been determined. The maintenance factor plus the general conditions have to be documented in the design process. (14) Cost of lamp replacement: Cost of the complete job of replacing the lamps, including the costs of the lamp and additional costs such as step ladders, weekend overtime payments or loss of production. (15) Cost of luminaire cleaning: Cost of the complete job of cleaning the luminaire plus replacing faulty components in the lighting system including parts costs. (16) Cost of room cleaning: Labour costs for cleaning room surfaces and restoring the reflection characteristics to their new condition. (17) Energy costs per kWh: Estimate a mixed price for high and low tariff. Include energy standing charges in the working price.
Economic analysis
Building project
Option 1 Luminaire type Luminaire data Number of lamps per luminaire System power of luminaire (W) Operating data Service life of system (y) Annual burning hours see Chap. 8/23 Lamp replacement interval (y) Luminaire cleaning interval (y) Room cleaning interval (y) Number of luminaires Maintenance factor Number of luminaires Itemised investment costs Cost of one luminaire Cost of one lamp
The Lighting Handbook
(11) (12) (13) (9) (10) (4) (5) (6) (7) (8) (2) (3) (1)
Option 2
Chapter 8 / 21
Option 1 Itemised operating costs Cost of lamp replacement Cost of luminaire cleaning Cost of room cleaning Energy costs per kWh Investment costs Luminaire costs (10) x (11) Lamp costs (10) x (2) x (12) Installation costs (10) x (13) Investment costs (18) + (19) + (20) Operating costs Lamp replacement costs (14) x (4) (6) Luminaire cleaning costs (15) x (4) (7) Room cleaning costs (16) x (4) (8) Energy costs (10) x (3) x (4) x (5) x (17) 1000 Operating costs (22) + (23) + (24) + (25) Annual operating costs (26) (4)
(22) (23) (24) (25) (26) (27) (18) (19) (20) (21) (14) (15) (16) (17)
Option 2
Pay-back period* =
years
Pay-back period* =
* excludes depreciation and interest
years
The Lighting Handbook
22 / Chapter 8
Working mode/shift type Burning hours per lamp and year in hours 8,760 7,300 4,960 3,720 3,100 1,760 2,580 1,550
Daylight-based control
Hours/day 24 24
No Yes
310 310
16 16
No Yes
310 310
10 10
No Yes
258 258
10 10
No Yes
Daylight-based control: the lamps switch on automatically when there is too little daylight available. Data is based on the assumption that there is sufficient available daylight for half the year.
From CIE publication 97 Maintenance of indoor electric lighting systems, dated 2005
Chapter 8 / 23
up to 60 %
up to 40 %
up to 17 %
up to 25 %
24 / Chapter 8
2. Improved ergonomic compatibility Pros 1. Increased productivity According to various studies, peoples productivity can be significantly improved by an upgraded lighting solution (e.g. research by TU Ilmenau, AIF no. 9955). 2. Fewer errors According to various studies, peoples error rate can be minimised by an upgraded lighting solution (e.g. research by TU Ilmenau, AIF no. 9955). 3. Increased alertness The human physiology is decoded step by step, allowing to perfectly adjust the lighting to the individual (e.g. doctoral thesis by Susanne Fleischer, ETH Zrich). 4. Enhanced sense of well-being Pleasant brightness levels and personal control can have a positive impact on peoples sense of well-being (e.g. Light Right Consortium). Potential savings
Please note: It is difficult to provide exact and generally applicable figures; however, measurable increases were achieved in individual cases. Minor increases already result in high economic benefits.
Chapter 8 / 25
3. Improved maintenance conditions (employment of staff for cleaning, maintenance and monitoring) Pros Potential savings up to +50 %
1. Extension of maintenance cycle Over recent years, the service life of lamps has been significantly extended (e.g. Philips Master TL-D Xtreme, AURA Ultimate LL). 2. Reduction in maintenance costs up to 30 % Contemporary luminaires frequently come in a closed design, allowing for easy cleaning (e.g. MELLOW LIGHT IV, LIGHTFIELDS, PERLUCE). 3. Automatic monitoring of installations up to 80 % Today, facility management tools allow for automatic, central monitoring of installations (e.g. in emergency lighting/ONLITE). 4. Energy savings up to 20 % Easy cleaning of luminaires, and extension of the maintenance cycle result in a reduced number of luminaires required, and thus energy savings (e.g. TECTON I IP). 4. Additional pros
Pros 1. Improvements in environmental factors Today, WEEE and RoHS provide the basis for manufacturing luminaires. Environmental impact has been reduced (e.g. lead/cadmium). 2. State of the art The latest lighting solutions reflect the state of the art and an improved situation in terms of lighting standards.
The following forms are intended to help you collect all relevant data required for evaluating the situation in terms of existing lighting installations. They provide the basis for comparing technical lighting features and for calculating costs.
26 / Chapter 8
Option 2
Luminaire type B
Number of luminaires Number of lamps per luminaire Type of ballast System power per luminaire including ballast (W) Illuminance
Total installed load in kW ON period each day (h) Working days per year Annual ON period (h) Power consumption in kWh/a
Room length Room width Room height Uniformity Emean = Emin = Room sketch: lx lx
% % %
28 / Chapter 8
Costs
Option 2
Error occurring
Possible cause
Possible solution
Luminaire was recently installed but cannot be switched on. 230 V 10 % Power reset
Use mains fuse to briefly switch off luminaire power, then switch on again.
With 3~ through-wiring in particular, overvoltages (400 V) may have occurred. N conductor has been confused with L conductor directly earthed conductor interrupted unbalanced load
Visually check electronic ballasts if there are any burn marks at mains input. Replace all units affected.
Chapter 8 / 29
Possible cause
Possible solution
Note
30 / Chapter 8
Use mains fuse to briefly switch off luminaire power, then switch on again.
Faulty lamp
Check cause: replace lamp/s for working lamp/s from adjacent luminaire. Fit new lamp/s if cause has been confirmed. In multi-lamp luminaires, all lamps have to be replaced (make voltage reset).
Wrong lamp
Check compatibility with ballast. Details on ballast label must conform with details printed on lamp.
Check by rotating lamp several times to left and right (approx. 180).
Error occurring
Possible cause
Possible solution
Dimmable luminaire already worked but suddenly cannot be switched on again. Power reset with bus signal
Use mains fuse to briefly switch off power. Actuate momentary-action switch at switchdim input (switching on/off).
Intermit signal in bus line (B1, B2 or Dali) (disconnect line). Use mains fuse to briefly switch off power. Then reconnect bus line and try to switch luminaire via control gear installed (LM or Dali).
Chapter 8 / 31
3. Additional test for HID luminaires (high-pressure lamps such as HIT, HST, etc.):
Note Checked
Error occurring
Possible cause
Possible solution
32 / Chapter 8
screw-fasten lamp as deeply as possible between lamp solder point and cap tab remove oxidation from lamp solder point, if necessary
4. Analysis of partial function of luminaires with electronic ballast (bad lighting quality of fluorescent lamp):
Note Checked
Error occurring
Possible cause
Possible solution
Use high-resistance voltmeter to measure power between phase and earth, and between neutral conductor and earth.
Check for heat buildup underneath high Common ceilings or at workplaces with very high temperature range: temperatures. Too low temperatures outside, 15 C < T < 35 C or heavy air flow (e.g. air-conditioning system). Cool Spot
Chapter 8 / 33
In order to achieve an appropriate lighting quality, new lamps should always be operated at 100 % for the first 100 hours of operation.
Chapter 9
Services
Design process and tools . . . . . . . . . . . . . . . . . . . . . . 3 5 ELI-LENI Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 VIVALDI Composing light . . . . . . . . . . . . . . . . . . . . . 7 ecoCALC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Online product information . . . . . . . . . . . . . . . . . . . . . 9 11 Product data sheets and installation instructions available online . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 CAD data in 2D and 3D available online . . . . . . . . . . 11 Online lighting design tools . . . . . . . . . . . . . . . . . . . . . 12 13 Zumtobel Lighting DVD . . . . . . . . . . . . . . . . . . . . . . . . 13 Zumtobel relies on quality . . . . . . . . . . . . . . . . . . . . . . 14 Lighting and sustainability . . . . . . . . . . . . . . . . . . . . . . 14
Requirement
Planning
Implementation
Design tools: Communication Product catalogue, brochures, ads and press work, trade fairs, congresses, events, roadshows, Light Forums ELI-LENI calculator Research projects, studies VIVALDI reference Library Online catalogue, QuickCalc, FluxCalc, system configurators, maintenance factor calculation, LM Energy VIVALDI visualisation, DIALux, Relux, ELI-LENI calculator, efficiency analysis, VIVALDI optimising
Requirement
Planning
Implementation
The Lighting Handbook
Chapter 9 / 3
Examples for using the lighting design programs: First-class lighting design ***** VIVALDI Chapter 9/7 DIALUX/POVRAY Chapter 9/13 3D-CAD Chapter 9/11 ECO CALC EXPERT Chapter 9/8 FLUX CALC Chapter 9/13 ELI/LENI CALCULATOR Chapter 9/6 time required = 2.5 days Example: see opposite page.
Quick and easy lighting design ** QUICK CALC Chapter 9/12 DIALUX LIGHT Chapter 9/13 ECO CALC WIZARD Chapter 9/8 LM ENERGY Chapter 9/13 time required = 4.5 hours Example:
The flying circus of lighting design **** light output ratio method correction factors The Lighting Handbook key data to be remembered n z L WF B A
4 / Chapter 9
Em =
n=
Chapter 9 / 5
ELI-LENI calculator
Award your lighting solution a quality seal. The ELI-LENI calculator calculates energy consumption in a straightforward manner based on the provisions of EN 15193 (LENI). The five descriptive quality criteria of any lighting solution (visual performance, vista, visual comfort, vitality and empowerment) are evaluated within only a few minutes by means of a questionnaire (ELI). Further information and downloads at: www.zumtobel.com/humanergybalance
6 / Chapter 9
Chapter 9 / 7
ecoCALC
Calculation of the costs for an integral lighting solution in terms of business performance, environmental aspects and maintenance. dimming via definable sequences over the course of the day monitoring of standby output various power tariffs can be indicated CO2, green criteria, maintenance cycles solution optimised by taking age-related change of lighting level into account taking account of dimming characteristics/profiles for use taking account of cut-off times analysis of categories: luminaires, controls, emergency lighting, accessories simple and experts analyses extensive default value and help functions several different components within a lighting solutions can be analysed as a whole application-specific analysis profiles More information/download: www.zumtobel.com/ecocalc
8 / Chapter 9
Product information available: photometric data sheets inc. UGR tables and maintenance factors data formats Eulumdat, IES CAD data: 2D and 3D Drag & drop data package for DIALux and Relux brochures installation instructions CE certificates
Chapter 9 / 9
10 / Chapter 9
Chapter 9 / 11
12 / Chapter 9
FluxCalc online (calculation of luminous flux): Using FluxCalc, the luminous flux of T16 and T26 lamps in relation to ambient temperature can be determined. For T16 lamps, FluxCalc also includes the influence of Zumtobels Cool Spot Optimizer in the calculation.
Chapter 9 / 13
14 / Chapter 9
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
Personal Notes
Chapter 10
United Kingdom Zumtobel Lighting Ltd. Unit 4 - The Argent Centre, Pump Lane Hayes/Middlesex UB3 3BL T +44/(0)20 8589 1800 F +44/(0)20 8756 4800 [email protected] www.zumtobel.co.uk USA and Canada Zumtobel Lighting Inc. 17-09 Zink Place Fair Lawn, New York 07410 T +1/(0)973/340 89 00 F +1/(0)973/340 98 98 [email protected] www.zumtobel.us Australia and New Zealand Zumtobel Lighting Pty Ltd 333 Pacific Highway North Sydney, NSW 2060 T +61/(2)8913 5000 F +61/(2)8913 5001 [email protected] www.zumtobel.com.au China Zumtobel Lighting China Shanghai office Room 101, No 192 YIHONG Technology Park Tianlin Road, Xuhui District Shanghai City, 200233, P.R. China T +86/(21) 6375 6262 F +86/(21) 6375 6285 [email protected] www.zumtobel.cn Hong Kong Zumtobel Lighting Hong Kong Unit 319, Level 43, Tower 1, Metroplaza, 223 Hing Fong Road, Kwai Chung, N.T. T +852/(0)2503 0466 F +852/(0)2503 0177 [email protected]
India Zumtobel Lighting GmbH Branch Office India S-605, Manipal Centre Dickenson Road 560042 Bangalore [email protected] United Arab Emirates Zumtobel Lighting GmbH (Branch) Dubai Airport Free Zone, Building 6W, B Block, 233 PO Box 54302 Dubai T +971/(0)4 299 3530 F +971/(0)4 299 3531 [email protected] Hungary Zumtobel Lighting Kft Lomb u. 15. 1139 Budapest T +36/(1) 35 00 828 F +36/(1) 35 00 829 [email protected] www.zumtobel.hu Croatia, Serbia, Bosnia and Herzegovina Zumtobel Licht d.o.o. Radnika cesta 80 Zagrebtower 10000 Zagreb T +385/(1) 64 04 080 F +385/(1) 64 04 090 [email protected] [email protected] [email protected] www.zumtobel.hr
Czech Republic and Slovak Republic Zumtobel Lighting s.r.o. Jankovcova 2 Praha 7 170 00 Praha T +420/(2) 66 782 200 F +420/(2) 66 782 201 [email protected] www.zumtobel.cz Poland Zumtobel Licht GmbH Sp.z.o.o. Przedstawicielstwo w Polsce ul. Narbutta 46/48 02-541 Warszawa T +48/(22) 856 7431 F +48/(22) 856 7432 [email protected] www.zumtobel.pl Slovenia Zumtobel Licht d.o.o. tukljeva cesta 46 1000 Ljubljana T +386/(1) 5609 820 F +386/(1) 5609 866 [email protected] www.zumtobel.si Russia Zumtobel Lighting GmbH Official Representative Office Skakovaya Str. 17 Bld. No 1, Office 1104 125040 Moscow T +7/(495) 945 36 33 F +7/(495) 945 16 94 [email protected] www.zumtobel.ru Norway Zumtobel Belysning Hoffsveien 4 Postboks 1025 Hoff 0218 Oslo T +47 22 06 50 50 F +47 22 06 50 52 [email protected] www.zumtobel.no
Sweden Zumtobel Belysning Birger Jarlsgatan 57 113 56 Stockholm T +46 8 26 26 50 F +46 8 26 56 05 [email protected] www.zumtobel.se Denmark Light Makers AS Indiavej 1 2100 Kbenhavn/Copenhagen T +45 35 43 70 00 F +45 35 43 54 54 [email protected] www.lightmakers.dk
Headquarters Zumtobel Lighting GmbH Schweizer Strasse 30 Postfach 72 6851 Dornbirn, AUSTRIA T +43/(0)5572/390-0 F +43/(0)5572/22 826 [email protected] Zumtobel Licht GmbH Grevenmarschstrasse 74-78 32657 Lemgo, GERMANY T +49/(0)5261 212-0 F +49/(0)5261 212-7777 [email protected] www.zumtobel.com
www.pefc.org
Order no. 04 797 525-EN 09/11 Zumtobel Lighting GmbH Technical data was correct at time of going to press. We reserve the right to make technical changes without notice. Please contact your local sales office for further information. For the sake of the environment: LuxoLight is chlorinefree paper from sustainably managed forests and certified sources.