APPLICATIONS MANUAL
CITROEN IMMOBILISER
CONTENTS
APPLICATIONS CONNECTOR LOCATIONS GENERAL OPERATION SPECIAL FUNCTIONS
PAGE
1.1 2.1 3.1 4.1
APM108
Version 2.0 03/02
APPLICATIONS
VEHICLE BERLINGO BERLINGO DISPATCH EVASION SAXO SYNERGIE XANTIA XSARA XSARA XSARA PICASSO
YEAR 1997 ON 1997 ON 1997 ON 1997 ON 1997 ON 1997 ON 1997 ON 1997 ON 1997 ON 1997 ON
SYSTEM IMMO 1 BSI IMMO 1 IMMO 1 IMMO 1 CPH CPH BSI CPH BSI
CABLE ADC110 ADC110 ADC110 ADC110 ADC110 ADC110 ADC100 + ADC120 ADC110 ADC110 ADC110
1.1
CONNECTOR LOCATIONS
XANTIA
XSARA
SAXO
2.1
GENERAL OPERATION
INTRODUCTION The Citroen Immobiliser systems are made up of 3 different types. They all perform various functions, and it is important to understand the basic configuration and the types of systems fitted. IMM STANDARD IMMOBILISER This system was the first transponder system fitted to the Citroen range of vehicles, after the keypad system was phased out. The system is a basic electronic control unit which consists of immobiliser unit, and transponder aerial to pick up the transponder signal code. This system is similar to the GM immobiliser system, and is programmed and diagnosed in much the same way. CPHPASSENGER COMPARTMENT PROTECTION CONTROL UNIT The next generation of Immobiliser and alarm system produced the CPH system which controls a number of additional components which further enhances the vehicle protection system. These include central door locking, ultrasonic passenger sensors to name a few. This system is programmed in much the same way, but offers additional functionality on live data and actuators functions. BSIBODY SYSTEMS INTERFACE This is the latest system, and the alarm and immobiliser have now been incorporated into the body control unit, which controls all body units, including wipers, indicators, lights, doors, windows, locks, boot, service interval, horn, etc. Again, with all the BSI because the immobiliser is part of a complicated system there are many more functions included, on actuators, special functions and live data.
3.1
SPECIAL FUNCTIONS
PROGRAMMING KEYSIMMOBILISER DIAGNOSTIC MENU ECU IDENTIFICATION FAULT CODES LIVE DATA ACTUATORS SPECIAL FUNCTIONS PRESS ENTER KEY DIAGNOSTIC MENU PROGRAM KEYS
Using the UP and DOWn keys select the PROGRAM KEYS option Select SPECIAL FUNCTIONS from the Diagnostic Menu using the UP and DOWN arrows. Then press the ENTER key.
PRESS ENTER KEY SECURITY CODE ____
To enter the security code use the following procedure :Press Press tion to elect Number & Letter To Erase the previous selecTo ENTER selection. To Finish PIN selection.
SECURITY CODE X4YT IS THIS CORRECT OK=ENTER CLEAR=BACK
Press Press
WARNING : WHEN PROGRAMMING KEYS, THE SYSTEM AUTOMATICALLY ERASES THE PLIP KEYS AT THE SAME TIME. BEFORE PROCEEDING WITH KEY PROGRAMMING, ENSURE YOU HAVE THE PLIP KEY PROGRAMMING PROCEDURE.
4.1
SPECIAL FUNCTIONS
Contd
If incorrect code is entered the screen will display as shown. NOTE : If the code is entered 3 time incorrectly, then the ECU will lock access for 15 minutes.
INCORRECT ACCESS CODE
PRESS ENTER KEY
SWITCH IGNITION ON IGNITION STATUS OFF
Follow on screen instruction for programming the keys.
SWITCH IGNITION OFF IGNITION STATUS ON
After switching IGNTION OFF remove the key and repeat procedure for additional keys.
4.2
SPECIAL FUNCTIONS
PROGRAMMING KEYSBSi MODULE DIAGNOSTIC MENU ECU IDENTIFICATION FAULT CODES LIVE DATA ACTUATORS SPECIAL FUNCTIONS PRESS ENTER KEY DIAGNOSTIC MENU PROGRAM KEYS
Using the UP and DOWn keys select the PROGRAM KEYS option Select SPECIAL FUNCTIONS from the Diagnostic Menu using the UP and DOWN arrows. Then press the ENTER key. NOTE : ENSURE ALL DOORS AL CLOSED WHEN KEY PROGRAMMING IS BEING PERFORMED.
PRESS ENTER KEY SECURITY CODE ____
To enter the security code use the following procedure :Press Press tion Press to elect Number & Letter To Erase the previous selecTo ENTER selection. To Finish PIN selection.
SECURITY CODE X4YT IS THIS CORRECT OK=ENTER CLEAR=BACK
Press
NOTE : AFTER PROGRAMMING CLEAR FAULT CODES AND LOCK VEHICLE FOR 10 MINUTES BEFORE TRYING THE KEY OR PLIP.
WARNING : WHEN PROGRAMMING KEYS, THE SYSTEM AUTOMATICALLY ERASES THE PLIP KEYS AT THE SAME TIME. BEFORE PROCEEDING WITH KEY PROGRAMMING, ENSURE YOU HAVE THE PLIP KEY PROGRAMMING PROCEDURE.
4.3
SPECIAL FUNCTIONS
Contd
If Access code is correct, ENTER the number of keys to program. NOTE : Max 4 keys can be added.
TRYING TO COMMUNICATE
PRESS ENTER KEY
SWITCH IGNITION OFF IGNITION STATUS ON
Follow on screen instruction for programming the keys.
PRESS ENTER KEY ERASING KEYS PROGRAMMING KEYS SWITCH IGNITION ON SWITCH IGNITION OFF REMOVE KEY FROM IGNITION INSERT NEXT KEY SWITCH IGNITION ON IGNITION STATUS OFF
4.4
SPECIAL FUNCTIONS
Contd
TRYING TO COMMUNICATE
PRESS ENTER KEY PRESS BACK TO EXIT PRESS ENTER TO PROGRAM NEXT KEY PRESS ENTER KEY
NOTE : AFTER PROGRAMMING CLEAR FAULT CODES AND LOCK VEHICLE FOR 10 MINUTES BEFORE TRYING THE KEY OR PLIP.
4.5