Note to detailer minimum of
three stiffeners centered
above bearing.
NOTES:
The bearing design shall conform to the provisions of the latest edition of
AASHTO.
Bent
1" Min.
Direction of
Longitudinal Movement
1 7/8 "
**
Pot Bearing
& Sole Plate
The contractor shall submit calculations sealed by a Professional
Engineer, licensed in the state of Missouri, indicating conformance with
design load and material criteria in the contract documents.
DATE PREPARED
07/28/2008
* Maximum vertical dimension of the complete bearing. If the actual
bearing dimension differs, adjustments shall be made in the thickness of
the sole plate, masonry plate and concrete pad as needed by the contractor
at no additional cost to the owner. Contractor shall submit proposed
method of adjustment to Engineer for approval.
Masonry PL
xx
xx
1/4 " to 5/8 "
5/8 " to 7/8 "
Anchor rods shall conform to ASTM F1554 Grade 55. The anchor rods shall be
the swedge-type and shall have a minimum diameter of 1 1/2-inches and
extend a minimum of __-inches into the concrete. Swedging shall be 1-inch
less than the extension into the concrete.
1/8 " to 1/4 "
Anchor rods shall be installed using a hardened steel washer at each
exposed location.
Washers shall conform to ASTM F463.
Longitudinal
Strength limit state
Vertical
Transverse
DETAIL OF 3/4" THRU
2 1/2" ANCHOR RODS
OPTIONAL DETAIL OF 1 3/8"
THRU 2 1/2" ANCHOR RODS
SWEDGE ANCHOR ROD DETAILS
Service limit state
Transverse
The sole plate shall be prepared per the specifications and shop-coated
with two coats of inorganic zinc primer (5 mils minimum).
Longitudinal
Rotation (rad.)
Strength limit state
Transverse
Notes:
Longitudinal
T2 is upstation of T1.
Service limit state
Transverse
*** One Way Longitudinal Movement is the maximum one way
movement (expansion or contraction) of the superstructure
when bearings are set at 70 degrees F plus 1" tolerance.
Longitudinal
*** One Way
Longit. Movement
**** On wide structures and on curved structures provisions
shall be made for limited lateral movement.
**** (G)
Guide Clearance
Masonry Plate
Wm
Indicates parts designed by the manufacturer.
La
After installation of the bearings, any uncoated or damaged surfaces of
the masonry and sole plates shall be prepared in accordance with the
specifications and field-coated with inorganic zinc primer (5 mils minimum)
After installation of the bearings and field-applied prime coats, the
surfaces of the masonry and sole plates shall be field-coated with System
G intermediate and finish coat.
All bearings shall be marked prior to shipping. The marks shall include
the bearing location on the bridge and a direction arrow that points
up-station. All marks shall be permanent and be visible after the bearing
is installed.
The pot bearing device, sole plate, masonry plate, anchor rods, washers,
anchor rod wells and any other appurtenances included in the fabrication
and installation of the pot bearing device shall be incidental to the pay
item "Pot Bearings".
Wa
Ta
Sole Plate
The bearing device, sole plate and masonry plate shall be assembled in the
shop and the bearing assembly shall be field welded to the bottom flange
of the steel cap beam. The welds shall be designed for the load capacities
indicated in the Bearing Data Table.
Lm
Tm
Auxilliary Plate
Certified mill test reports, conforming to the requirements of the
specifications, for the metals of the pot bearing device, sole plate,
masonry plate and anchor rods shall be submitted.
The masonry plate shall be prepared per the specifications and shop-coated
with one coat of inorganic zinc primer (5 mils minimum).
Longitudinal
Translation
BRG 11
All expansion Bearings shall have maximum friction coefficient of 3%.
Steel for pot bearings shall be AASHTO M270 Grade 50 and shall be
galvanized. Steel for sole plate and masonry plates shall be AASHTO M270
Grade 50.
1"
1/8 "
5/8 " to 7/8 "
3 1/2 "
2 1/2 " to
spaces
4 Equal 1"
1/4 " to 5/8 "
min.
Transverse
BRIDGE NO.
105 WEST CAPITOL
Surface of
concrete
Fix/Exp.
perm.
PROJECT NO.
The bearings shall be manufactured pot bearings, designed for the load and
movement capacities indicated in the Bearing Data Table.
Surface of
concrete
max.
***** The temperature of the steel adjacent to the elastomeric should be
kept below 250^F.
The dimension "H" in the Bearing Data Table represents the assumed total
height of bearing mechanism between the sole plate and masonry plate used
by the designer to establish the pedestal elevations.
BEARING DATA TABLE
Vertical
JOB NO.
CONTRACT ID.
POT BEARING PLAN
Location
Quan. Reqd.
*
COUNTY
DESCRIPTION
ELEVATION
BR
** Estimated horizontal dimension of the pot bearing device. If the actual
dimension differs, adjust the size of the sole plate and masonry plate as
needed by the contractor at no additional cost to the owner.
Pot Bearing
Anchor Rod Well to be sized by
Contractor and coordinated with
anchor rod requirements of pot
bearing manufacturer. The cost
of the wells shall be incidental
to the cost of the pot bearing
device
MO
SHEET NO.
DATE
Swedge Anchor
Rod (Typ.)
Sole Plate
Threaded
Coupling
Nut (Typ.)
STATE
*
DISTRICT
COMMISSION
Min.
Service limit state
DOCUMENT."
ROUTE
Washer (Typ.)
Concrete
Pedestal
Design load
(kip)
NOT BE CONSIDERED
The contractor, in coordination with the bearing manufacturer, shall be
responsible for sizing the sole plate and masonry plate and determining
the size, number, and location of anchor rods based on the load and
movement capacities, indicated in the Bearing Data.
JEFFERSON CITY, MO 65102
Pot Bearing Device
7 1/2 "
"THIS MEDIA SHOULD
A CERTIFIED
Direction of
Transverse Movement
xx
"
Top of
Pier Cap
Assembly
H *
*****
Bearing
Bevel Sole
Plate to match
slope of beam
Ls
Whenever jacking of the Superstructure is needed to reset the bearings,
the contractor shall submit a jacking sequence for approval.
Ws
T1
T2
Bearing H
Anchor Rods
d
Rods / Brg.
Weld Size
W1
W2
DETAILS OF POT BEARING PAD ASSEMBLY
Detailed
Checked
Note: This drawing is not to scale. Follow dimensions.
Sheet No.
of
brg11_pot_bearing.dgn
09:17:52 AM
07/28/2008
IF A SEAL IS PRESENT ON THIS SHEET IT HAS BEEN ELECTRONICALLY SEALED AND DATED.
Supercedes: Nov. 2007
1-888-ASK-MODOT (1-888-275-6636)
Effective: Aug. 2008
MISSOURI HIGHWAYS AND TRANSPORTION
brg11_pot_bearing