ELD Series Air Cooled Oil Coolers

These oil coolers use high performance cooling elements and long life DC fans to provide trouble-free cooling for mobile hydraulic applications. They have a compact design that fits most equipment while maximizing heat dissipation and minimizing space. Features include internal pressure bypass, built-in thermostat ports, and cooling capacities up to 50 HP with flow rates up to 45 gpm. They are suitable for applications in agriculture, railways, automotive, construction, and commercial/municipal industries.

Uploaded by

Avneet Maan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views6 pages

ELD Series Air Cooled Oil Coolers

These oil coolers use high performance cooling elements and long life DC fans to provide trouble-free cooling for mobile hydraulic applications. They have a compact design that fits most equipment while maximizing heat dissipation and minimizing space. Features include internal pressure bypass, built-in thermostat ports, and cooling capacities up to 50 HP with flow rates up to 45 gpm. They are suitable for applications in agriculture, railways, automotive, construction, and commercial/municipal industries.

Uploaded by

Avneet Maan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Coolers

ELD Series

Air Cooled Oil Coolers


for Mobile Applications

Hydraulic Symbol
Sizes 1 - 4.5

Sizes 5 - 6

Description

These coolers use a combination of high performance cooling


elements combined long life DC electrical powered fans to give long
trouble free operation in mobile hydraulic applications. The compact
design allows the coolers to fit most equipment and provide the
highest cooling performance in heat dissipation while minimizing
space required.

Applications

Agricultural

Features
M
 ost coolers are designed with the inlet/outlet ports facing
toward the back to help reduce fittings
Available with internal pressure bypass

Railways

All units feature a built in thermostat port


12 and 24 volt DC fans
Up to 50 HP cooling capacity
Rated flows up to 45 gpm
Motor lifetimes up to 8,000 hours

Cooling Systems Catalog

Automotive

Construction

Commercial
Municipal

Coolers
Model Code
ELD 1H 3.5 12 S F X
Model
ELD

Air Cooled Oil Cooler with DC Motor Drive

Size
1H
1.5H
2H
3H
4H
4.5H
5H
6H

(see heat dissapation table on page 5)

Modification Number (latest version always supplied)


Motor Drive Voltage
12
= 12 volt DC
24
= 24 volt DC
Air Flow Direction
S
= Suction (standard)
B
= Blowing (consult factory)
Accessories
TS 140 =
F
=
IBP
=

140F set point (Additional set points available - consult factory)


Optional Foot Mount
Inegrated bypass valve

Opening Pressure Drop (IBP Only)


2
= 2 bar (29 psi)
3
= 3 bar (45 psi)

Cooling Systems Catalog

Coolers
ELD Series
Heat Dissapation
50

Tolerance: +/- 5%
ELD 6

45
40

ELD 5

35
30

ELD 4.5

25

ELD 4

20

ELD 3

15
ELD 2

10

ELD 1.5

5
0

ELD 1
0

10

15

20

25

30

35

40

45

Oil flow [GPM]

50

55

60

65

Pressure Drop
ELD 1: +/- 5%
60.0

Pressure Drop @ 30 mm/s (PSI)

55.0
ELD 1

50.0
45.0
40.0

ELD 1.5

35.0

ELD 5

30.0
25.0

ELD 3

ELD 6

20.0
ELD 4

15.0

ELD 2

10.0
5.0

ELD 4.5

0.0
0

20

40

60

80

Oil flow (GPM)


*Values measured at T = 72F, may vary at lower dT values
*Pressure Drop Curves above using fluid with a viscosity of 30 mm2/s.
For other viscosities the result must be multiplied by the K Factors below.

Viscosity (SSU)

46

70

102

150

213

250

315

464

695

Viscosity (mm2 /s)

10

15

22

32

46

54

68

100

150

K Factor

0.5

0.65

0.77

1.3

1.52

1.9

2.8

5.3

Cooling Systems Catalog

Coolers
Engineering Data
Motor Capacity
(kW)

Amp Draw

Recommended Fuse (A)

Protection
Class IP

Fan Diameter
(mm)

Noise Level
dBa* (1 meter)

Weight
(lbs.)

ELD 1
12 volt / 24 volt

0.11 / 0.11

8 / 3.2

15 / 7.5

67

190

73

8.8

ELD 1.5
12 volt / 24 volt

0.11 / 0.11

8 / 3.2

15 / 7.5

67

190

73

8.8

ELD 2
12 volt / 24 volt

0.16 / 0.16

9.4 / 5.2

20 / 15

67

255

74

20.688

ELD 3
12 volt / 24 volt

0.26 / 0.26

17.5 / 8.0

25 / 20

67

305

79

24.2

ELD 4
12 volt / 24 volt

0.35 / 0.35

22.5 / 10.5

30 / 20

67

385

76

34.98

ELD 4.5
12 volt / 24 volt

0.35 / 0.35

22.5 / 10.5

30 / 20

67

385

76

48.4

ELD 5
12 volt / 24 volt

0.53 / 0.53

35.0 / 16.0

2x25 / 2x20

67

305

80

66.66

ELD 6
12 volt / 24 volt

0.69 / 0.69

45.0 / 21.0

2x30 / 2x20

67

385

77

80.52

Size

*The noise levels are only a guide as acoustic properties vary and depend on the characteristics of the room, connections, viscosity, and resonance.

Construction
Housing

Welded Steel

Heat Exchanger

Aluminum

Fan

Plastic

Maximum Viscosity

2000 cst.

Maximum Oil Temperature

266F

Maximum Operating Pressure

230 psi

Mounting Position

All positions

Fan Rotation

See arrow on fan

Fluids

Mineral Oil to Din 51524 Part 1 and 2

Accessories
Foot Bracket - ELD 2-6 & ELH 2-5
1.97"
50mm

2.15"
54.50mm

5.73"
145.50mm
0.16"
4mm

1.97"
50mm

0.93"
23.50mm

0.43"
3x 11mm
0.71"
18mm

R5

(4
x)

1.42"
36mm

0.79"
20mm

3.35"
85mm

4.92"
125mm

1.81"
46mm
0.35"
9mm
R5 (4x)

2.36"
60mm

0.51"
13mm

0.79"
20mm

9.84"
250mm

0.75"
19mm

0.16"
4mm

Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.
Dimensions are in inches/(mm).

Cooling Systems Catalog

Coolers
ELD Series
Dimensions
Sizes 1 - 4

W2

W1

Thermostat Port
E5

E5

E1

AIR FLOW
OPTIONAL

E2

A1

E4

STANDARD

F-Mounting Hole
(6 Places)

Z1 (2x)
Oil Port (2 Places)

E3
C1

Size

A1

C1

E1

E2

E3

E4

E5

W1

W2

Z1

Thermostat
Port

ELD 1

9.65

4.72

11.81

4.92

2.36

9.84

8.86

3.54

0.35

7.87

3.94

1 1/16-12 UN

1/2 NPT

ELD 2

12.32

8.27

15.12

7.83

2.24

12.76

11.34

3.15

0.55 x 0.4

9.84

5.91

1 5/16-12 UN

1/2 NPT

ELD 3

14.02

8.27

16.54

9.06

2.48

14.57

12.95

3.94

0.55 x 0.4

11.81

7.09

1 5/16-12 UN

1/2 NPT

ELD 4

17.72

7.83

19.69

11.38

3.17

17.72

16.57

5.91

0.63 x 0.4

15.75

7.87

1 5/16-12 UN

1/2 NPT

Size 1.5
Z1
Oil Port
(2 Places)

W2

E6

A1

W1

Thermostat
Port

E3

E1

(4x) F

E4

E2
E7

E5

C1

Size
ELD 1.5

A1

C1

E1

E2

E3

E4

E5

E6

E7

W1

W2

Z1

Thermostat
Port

8.07

5.30

11.81

1.22

1.54

10.04

4.76

1.57

0.89

0.49

5/16-18 UNC

0.31

0.16

1 1/16-12 UN

1/2 NPT

Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.
Dimensions are in inches.

Cooling Systems Catalog

Coolers
ELD Series
Dimensions
Sizes 4.5

W2

W2

E5

B
Z1 (2x)

W1

W1

F - Mounting Hole
(4 places)

E1

E4

AIR FLOW
DIRECTION

A1

STANDARD
AIR FLOW

PER REQUEST

STANDARD

OPTIONAL
Thermostat Port

E2

E3

Size
ELD 4.5

C1

A1

C1

E1

E2

E3

E4

E5

W1

W2

Z1

Thermostat
Port

17.87

8.58

23.70

13.78

2.05

19.29

7.87

11.42

0.472

15.75

7.87

1 5/8-12 UN

1/2 NPT

Sizes 5 - 6
E5

Thermostat Port

E2

E1

E5

E4

A1

E5

F - Mounting Hole (8 places)

E3
C1
Size

A1

C1

Z1
Oil Port (2 places)

E1

E2

E3

E4

E5

W1

W2

Z1

Thermostat
Port

ELD 5

18.70

9.25

31.89

12.64

3.03

29.53

17.72

6.69

0.63 x 0.35

15.75

7.87

1 5/8-12 UN

1/2 NPT

ELD 6

20.94

8.86

37.40

14.69

3.11

35.04

19.80

7.87

0.71 x 0.35

19.69

9.84

1 5/8-12 UN

1/2 NPT

Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.
Dimensions are in inches.

Cooling Systems Catalog