Coolers
ELD Series
Air Cooled Oil Coolers
for Mobile Applications
Hydraulic Symbol
Sizes 1 - 4.5
Sizes 5 - 6
Description
These coolers use a combination of high performance cooling
elements combined long life DC electrical powered fans to give long
trouble free operation in mobile hydraulic applications. The compact
design allows the coolers to fit most equipment and provide the
highest cooling performance in heat dissipation while minimizing
space required.
Applications
Agricultural
Features
M
ost coolers are designed with the inlet/outlet ports facing
toward the back to help reduce fittings
Available with internal pressure bypass
Railways
All units feature a built in thermostat port
12 and 24 volt DC fans
Up to 50 HP cooling capacity
Rated flows up to 45 gpm
Motor lifetimes up to 8,000 hours
Cooling Systems Catalog
Automotive
Construction
Commercial
Municipal
Coolers
Model Code
ELD 1H 3.5 12 S F X
Model
ELD
Air Cooled Oil Cooler with DC Motor Drive
Size
1H
1.5H
2H
3H
4H
4.5H
5H
6H
(see heat dissapation table on page 5)
Modification Number (latest version always supplied)
Motor Drive Voltage
12
= 12 volt DC
24
= 24 volt DC
Air Flow Direction
S
= Suction (standard)
B
= Blowing (consult factory)
Accessories
TS 140 =
F
=
IBP
=
140F set point (Additional set points available - consult factory)
Optional Foot Mount
Inegrated bypass valve
Opening Pressure Drop (IBP Only)
2
= 2 bar (29 psi)
3
= 3 bar (45 psi)
Cooling Systems Catalog
Coolers
ELD Series
Heat Dissapation
50
Tolerance: +/- 5%
ELD 6
45
40
ELD 5
35
30
ELD 4.5
25
ELD 4
20
ELD 3
15
ELD 2
10
ELD 1.5
5
0
ELD 1
0
10
15
20
25
30
35
40
45
Oil flow [GPM]
50
55
60
65
Pressure Drop
ELD 1: +/- 5%
60.0
Pressure Drop @ 30 mm/s (PSI)
55.0
ELD 1
50.0
45.0
40.0
ELD 1.5
35.0
ELD 5
30.0
25.0
ELD 3
ELD 6
20.0
ELD 4
15.0
ELD 2
10.0
5.0
ELD 4.5
0.0
0
20
40
60
80
Oil flow (GPM)
*Values measured at T = 72F, may vary at lower dT values
*Pressure Drop Curves above using fluid with a viscosity of 30 mm2/s.
For other viscosities the result must be multiplied by the K Factors below.
Viscosity (SSU)
46
70
102
150
213
250
315
464
695
Viscosity (mm2 /s)
10
15
22
32
46
54
68
100
150
K Factor
0.5
0.65
0.77
1.3
1.52
1.9
2.8
5.3
Cooling Systems Catalog
Coolers
Engineering Data
Motor Capacity
(kW)
Amp Draw
Recommended Fuse (A)
Protection
Class IP
Fan Diameter
(mm)
Noise Level
dBa* (1 meter)
Weight
(lbs.)
ELD 1
12 volt / 24 volt
0.11 / 0.11
8 / 3.2
15 / 7.5
67
190
73
8.8
ELD 1.5
12 volt / 24 volt
0.11 / 0.11
8 / 3.2
15 / 7.5
67
190
73
8.8
ELD 2
12 volt / 24 volt
0.16 / 0.16
9.4 / 5.2
20 / 15
67
255
74
20.688
ELD 3
12 volt / 24 volt
0.26 / 0.26
17.5 / 8.0
25 / 20
67
305
79
24.2
ELD 4
12 volt / 24 volt
0.35 / 0.35
22.5 / 10.5
30 / 20
67
385
76
34.98
ELD 4.5
12 volt / 24 volt
0.35 / 0.35
22.5 / 10.5
30 / 20
67
385
76
48.4
ELD 5
12 volt / 24 volt
0.53 / 0.53
35.0 / 16.0
2x25 / 2x20
67
305
80
66.66
ELD 6
12 volt / 24 volt
0.69 / 0.69
45.0 / 21.0
2x30 / 2x20
67
385
77
80.52
Size
*The noise levels are only a guide as acoustic properties vary and depend on the characteristics of the room, connections, viscosity, and resonance.
Construction
Housing
Welded Steel
Heat Exchanger
Aluminum
Fan
Plastic
Maximum Viscosity
2000 cst.
Maximum Oil Temperature
266F
Maximum Operating Pressure
230 psi
Mounting Position
All positions
Fan Rotation
See arrow on fan
Fluids
Mineral Oil to Din 51524 Part 1 and 2
Accessories
Foot Bracket - ELD 2-6 & ELH 2-5
1.97"
50mm
2.15"
54.50mm
5.73"
145.50mm
0.16"
4mm
1.97"
50mm
0.93"
23.50mm
0.43"
3x 11mm
0.71"
18mm
R5
(4
x)
1.42"
36mm
0.79"
20mm
3.35"
85mm
4.92"
125mm
1.81"
46mm
0.35"
9mm
R5 (4x)
2.36"
60mm
0.51"
13mm
0.79"
20mm
9.84"
250mm
0.75"
19mm
0.16"
4mm
Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.
Dimensions are in inches/(mm).
Cooling Systems Catalog
Coolers
ELD Series
Dimensions
Sizes 1 - 4
W2
W1
Thermostat Port
E5
E5
E1
AIR FLOW
OPTIONAL
E2
A1
E4
STANDARD
F-Mounting Hole
(6 Places)
Z1 (2x)
Oil Port (2 Places)
E3
C1
Size
A1
C1
E1
E2
E3
E4
E5
W1
W2
Z1
Thermostat
Port
ELD 1
9.65
4.72
11.81
4.92
2.36
9.84
8.86
3.54
0.35
7.87
3.94
1 1/16-12 UN
1/2 NPT
ELD 2
12.32
8.27
15.12
7.83
2.24
12.76
11.34
3.15
0.55 x 0.4
9.84
5.91
1 5/16-12 UN
1/2 NPT
ELD 3
14.02
8.27
16.54
9.06
2.48
14.57
12.95
3.94
0.55 x 0.4
11.81
7.09
1 5/16-12 UN
1/2 NPT
ELD 4
17.72
7.83
19.69
11.38
3.17
17.72
16.57
5.91
0.63 x 0.4
15.75
7.87
1 5/16-12 UN
1/2 NPT
Size 1.5
Z1
Oil Port
(2 Places)
W2
E6
A1
W1
Thermostat
Port
E3
E1
(4x) F
E4
E2
E7
E5
C1
Size
ELD 1.5
A1
C1
E1
E2
E3
E4
E5
E6
E7
W1
W2
Z1
Thermostat
Port
8.07
5.30
11.81
1.22
1.54
10.04
4.76
1.57
0.89
0.49
5/16-18 UNC
0.31
0.16
1 1/16-12 UN
1/2 NPT
Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.
Dimensions are in inches.
Cooling Systems Catalog
Coolers
ELD Series
Dimensions
Sizes 4.5
W2
W2
E5
B
Z1 (2x)
W1
W1
F - Mounting Hole
(4 places)
E1
E4
AIR FLOW
DIRECTION
A1
STANDARD
AIR FLOW
PER REQUEST
STANDARD
OPTIONAL
Thermostat Port
E2
E3
Size
ELD 4.5
C1
A1
C1
E1
E2
E3
E4
E5
W1
W2
Z1
Thermostat
Port
17.87
8.58
23.70
13.78
2.05
19.29
7.87
11.42
0.472
15.75
7.87
1 5/8-12 UN
1/2 NPT
Sizes 5 - 6
E5
Thermostat Port
E2
E1
E5
E4
A1
E5
F - Mounting Hole (8 places)
E3
C1
Size
A1
C1
Z1
Oil Port (2 places)
E1
E2
E3
E4
E5
W1
W2
Z1
Thermostat
Port
ELD 5
18.70
9.25
31.89
12.64
3.03
29.53
17.72
6.69
0.63 x 0.35
15.75
7.87
1 5/8-12 UN
1/2 NPT
ELD 6
20.94
8.86
37.40
14.69
3.11
35.04
19.80
7.87
0.71 x 0.35
19.69
9.84
1 5/8-12 UN
1/2 NPT
Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.
Dimensions are in inches.
Cooling Systems Catalog