Technical Data
1442 Eddy Current Probe Systems Specifications
Catalog Numbers 1442-PS series, 1442-PR series, 1442-EC series, 1442-DR series
Topic
Page
Non-contact Pick-up Probe System
Wiring Guidelines
Match System Components by Color
1442 Series Probe System Specifications
1442 Series Catalog Numbers
Accessories
17
The 1442 series of eddy current probe systems serve applications with measurement ranges from 0.129 mm
(41142 mils). 1442 series probe systems fully satisfy the requirements of API 670 and are suitable for any type of dynamic
or static displacement measurement, including vibration, speed/acceleration, rotor/position, and differential expansion
measurements.
Summary of Changes
This manual contains new and updated information. Changes throughout this revision are marked by change bars, as
shown to the right of this paragraph.
Topic
Page
Corrected wire sizes
3, 5
Corrected temperature ranges for CSA and ATEX
Corrected c-CSA-us and Ex certification information
1442 Eddy Current Probe Systems Specifications
Non-contact Pick-up Probe System
A non-contact pick-up probe system is composed of three components.
Sensor
Connector
Extension Cable
Driver
Component
Description
Non-contact pick-up probe
The non-contact pick-up probe is an encapsulated wire configuration that reads the relative position of the equipment
by introducing eddy currents into the target material and measuring the change in the current as the target surface
moves. The energy loss into the target increases or decreases as the target moves nearer to or farther away from the
probe. The change in energy loss is detected as a change in the modulated signal. This change provides a voltage
proportional to the gap between the probe tip and the target. This signal is fed to the monitoring system, providing a
continuous and very accurate measure of the relative distance to the target surface.
The tip diameter characterizes the probe. In general, the wider the tip, the greater the range that the probe can sense.
Choose other characteristics, such as the body length and the thread size, based on the application.
Extension cable
The extension cable provides flexibility for placement of the probe by allowing extended lengths between the driver
and the non-contact pick-up. A variety of Teflon-insulated and Armor-coaxial extension cables adapt the sensor system
to most installations. The extension cables are electrically matched to the selected probe system.
Driver
The driver systems are case isolated and can be DIN-rail or panel mounted. The stainless-steel probe drivers provide the
radio frequency that powers the probe system. The driver is the primary component responsible for signal conditioning,
providing accurate linearity over the operating range of the system.
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Wiring Guidelines
When wiring the probe driver to a monitor, consider the following recommendations:
Use a good quality instrumentation cable with three-conductor stranded wire and shield. Also consider the
following:
Use wire rated with a maximum capacitance of 60 pF/ft (197 pF/m) and inductance of 0.3 H/ft (1 H/m).
Use wire with insulation suitable for the environment and with adequate tensile strength and flexibility for the
application.
Use wire with a foil shield for use in environments where radio frequency interference (RFI) can be present.
Use wire with a braid shield for environments where electromagnetic interference (EMI) can be present.
Use 0.751.25 mm2 (1816 AWG).
Make sure the wire is isolated from power cables and any other wiring that can be transmitting high voltage power or
control signals.
Isolate any cable transmitting pulse-type vibration signals, such as a phase marker or speed pulse, from displacement
and vibration signals.
Run wire within conduit and cable trays and as per any local electrical codes.
Do not exceed 500 m (1640 ft). However, limiting the length to 300 m (984 ft) guarantees that vibration signals in
the 010 kHz frequency range are transmitted with minimal attenuation. When longer lengths are needed, the
capacitance of the cable and the desired frequency response of the system must be considered.
In most cases, make sure that the cable shield is grounded at only one point, generally at the monitor.
Match System Components by Color
The 1442 probe systems use color-coded bands to match probes and extension cables with the appropriate driver. The
color-coded bands provide a system to identify the length of the extension cable and the length of the probe so that the
total system length, 5 or 9 m (16 or 29 ft), can be matched to the appropriate driver. When a system is properly sized, the
color bands on either side of the connectors between the probe, extension cable, and driver will match.
Table 1 - 1442 Series Color Bands
Sensor
Extension Cable
Driver
Cable Length
Color Band
Length
Probe End Color
Band
Driver End Color
Band
System Cable
Length
Color Band
0.5 m (1.64 ft)
Yellow
4.0 m (13.12 ft)
Black
Blue
5.0 m (16.40 ft)
Blue
1.0 m (3.28 ft)
Black
4.5 m (14.76 ft)
Yellow
Blue
9.0 m (29.53 ft)
Red
8.0 m (26.25 ft)
Black
Red
8.5 (27.89 ft)
Yellow
Red
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
1442 Series Probe System Specifications
Table 2 - Individual Technical Specifications
Attribute
5 mm
(0.20 in.)
8 mm
(0.31 in.)
11 mm
(0.43 in.)
Applications (typical)
Vibration, speed, or thrust
Linear range, approx(1)
2 mm
(80 mils)
4.5 mm
(180 mils)
Linear range from
sensor tip, approx(1)
0.252.25 mm
(9.888.6 mils)
Sensitivity(1)
Frequency response
18 mm
(0.71 in.)
25 mm
(1 in.)
50 mm
(1.97 in.)
6.0 mm
(246 mils)
13.5 mm
(532 mils)
26 mm
(1024 mils)
0.55.0 mm
(20200 mils)
0.56.5 mm
(20256 mils)
316.5 mm
(118650 mils)
329 mm
(1181142 mils)
7.87 V/mm
(200 mV/mil)
3.94 V/mm
(100 mV/mil)
2.5 V/mm
(63.5 mV/mil)
0.8 V/mm
(20.3 mV/mil)
0.4 V/mm
(10.15 mV/mil)
DC to 10 kHz (-3 dB)
DC to 10 kHz (-3 dB)
Differential expansion
DC to 200 Hz (-3 dB)
5 m (16 ft) System Length
Scale factor error(1) (2)
Within 7.87 V/mm 5%
Within 3.94 V/mm
10%
Linearity (2)
Within 25 m (1 mil) for a straight line of
7.87 V/mm
Within 100 m for a
straight line of
3.94 V/mm
Within 90 m for a
straight line of
2.5 V/mm
Within 10% of
3.94 V/mm
(100 mV/mil)
Within 270 m for a
straight line of
0.8 V/mm
Within 400 m for a
straight line of
0.4 V/mm
14 mm (0.55 in.)
25 mm (0.98 in.)
9 m (29 ft) System Length
Scale factor error(1) (2)
Within 6.5% of 7.87 V/mm (200 mV/mil)
Operating temperature characteristics(3)
Sensor(4)
< 3% of F.S.
Extension cable(4)
< 4% of F.S.
Driver(4)
< 3% of F.S.
Apply with gap
2 mm (0.08 in.)
< 3% of F.S.
4 mm (0.16 in.)
5 mm (0.20 in.)
(1) Applies at 25 C (77 F) with -24V DC power supply, load resistance 10 k, and AISI 4140 (JIS SCM440) steel flat surface target (thickness 5 mm).
(2) Includes interchangeability errors.
(3) Applies when target is AISI 4140 (JIS SCM440) steel, flat, and with a thickness of >= 5mm (0.2 in.).
(4) Applies at temperatures from 0...80 C (176 F) and is 0 % F.S. at standard 20 C (68 F).
Table 3 - Common Technical Specifications
Attribute
1442 Series Probe Systems
Standard calibration
AISI 4140 (JIS SCM440) steel flat surface
Maximum output voltage, approx(1)
-23V DC
Sensor abnormal output voltage, approx(1)
-0.6V DC (sensor OPEN or SHORT)
Current consumption (10 k load), max
-15 mA
Output noise, approx(1)
20 mV peak-to-peak + power supply noise
Cable diameter, approx
2.7 or 3.6 mm (0.11 or 0.14 in.)
Connector diameter, approx
7.1 mm (0.28 in.)
Connector diameter (armored), approx
5.8 mm (0.23 in.)
System cable length
5 or 9 m (16.40 or 29.53 ft) nominal
Probe integral cable variance
+30% / -0%
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Table 3 - Common Technical Specifications
Attribute
1442 Series Probe Systems
Extension cable variance
+20% / -0%
Power supply
-24V DC
Driver insulation resistance
Between terminals and mounting plate: 100 M @ 500V DC
Terminal block
Spring lock terminal
Isolation voltage (driver)
50V (continuous), Basic Insulation Type, terminals to mounting plate
Type tested at 500V AC for 60 s
Wiring category(2)
2 - on signal ports
Wire size (driver)
0.751.25 mm2 (1816 AWG) shielded stranded-copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.)
insulation max
Driver mass, approx
200 g (7.0 oz.)
(1) Applies at 25 C (77 F) with -24V DC power supply, load resistance 10 k, and AISI 4140 (JIS SCM440) steel flat surface target (thickness 5 mm).
(2) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 4 - Environmental Specifications
Attribute
1442-Px Probe
1442-DRx Driver
Temperature, operating (Hazardous Area)
ATEX applications: -3580C (-31176 F)
CSA applications: -3585C (-31185 F)
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-35177C (-31350 F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
3095% RH (noncondensing, nonsubmerged)
Sensor body: 100% RH
Vibration
IEC 60068-2-6 (Test Fc, Operating)
1 g @ 10150 Hz
Emissions
CISPR11 (IEC 61000-6-4)
Class A
Class A
Ferrite required
ESD immunity
IEC 61000-4-2
6 kV contact discharges
8 kV air discharges
Metal enclosure required
6 kV contact discharges
8 kV air discharges
Metal enclosure required
Ferrite required
Radiated RF immunity
IEC 61000-4-3
10V/m with 1 kHz sine-wave 80%
AM from 802000 MHz
3V/m with 1 kHz sine-wave 80% AM
from 14002000 MHz
1V/m with 1 kHz sine-wave 80% AM
from 20002700 MHz
Metal enclosure required
10V/m with 1 kHz sine-wave 80%
AM from 802000 MHz
3V/m with 1 kHz sine-wave 80% AM
from 14002000 MHz
1V/m with 1 kHz sine-wave 80% AM
from 20002700 MHz
Metal enclosure required
Ferrite required
EFT/B immunity
IEC 61000-4-4
1 kV at 5 kH on shielded signal
ports
Metal conduit required
1 kV at 5 kH on shielded signal
ports
Metal conduit required
Ferrite required
-3080 C (-22176 F)
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442-ECx Extension Cable
-35177 C (-31350 F)
Connector: -35125 C
(-31257 F)
1442 Eddy Current Probe Systems Specifications
Table 4 - Environmental Specifications
Attribute
1442-Px Probe
1442-DRx Driver
1442-ECx Extension Cable
Surge transient immunity
IEC 61000-4-5
1 kV line-earth (CM) on shielded
signal ports
1 kV line-earth (CM) on shielded
signal ports
Ferrite required
Conducted RF immunity
IEC 61000-4-6
10V rms with 1 kHz sine-wave 80%
AM from 150 kHz80 MHz
Metal conduit required
10V rms with 1 kHz sine-wave 80%
AM from 150 kHz80 MHz
Metal conduit required
Ferrite required
Magnetic field immunity
IEC 6100-4-8
30 A/m long duration at 50 Hz
Enclosure type rating
None (open-style)
North American temp code
T4
IEC temp code
T4
Table 5 - Certifications
Certification(1)
1442 Series Probe Systems
c-CSA-us
CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for US and
Canada. See CSA File 216284.
CSA Certified Process Control Equipment for Class I, Division 1, Group A,B,C,D Hazardous Locations, certified for US and
Canada. See CSA File 216284.
Ex/AEx ia IIC T4, Tamb +85 C
Vmax or Ui=26.6V, Imax or Ii=138 mA, Pmax or Pi=0.824 W, Ci=70 nF, Li=0.2 mH
CE
European Union 2004/108/EC EMC Directive, compliant with:
EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61326-2-3; Transducers
C-Tick
Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
Ex
European Union 94/9/EC ATEX Directive, compliant with:
EN 60079-11; Explosive Atmospheres, Protection "i"
EN 60079-0; General Requirements
II 1 G Ex ia IIC T4 Ga, -30 C Tamb +80 C
Ui: 26V, Ii: 138 mA, Pi: 0.81 W, Ci: 70 nF, Li: 0.06 mH
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
1442 Series Catalog Numbers
Catalog numbers consist of various characters that identify a specific option for the probe system. Use the following tables
to determine the catalog number for your probe system.
1442 Series Standard Mount Probes
05 03 M 00 10 N
1442-PS ------ ------ ----- ------ ------ ---a b c d e f
a
Probe Diameter
Body Length(1)
Thread
Metric
Code
Description
Imperial
Code
Description
Code
Description
Code
M
Metric
M8x1 thread (5 mm probe)
M10x1 thread (8 mm probe)
Imperial
1/4-28 UNF thread (5 mm probe)
3/8-24 UNF thread (8 mm probe)
Not threaded (flange mount)
05
5 mm (0.20 in.)
03
30 mm
12
1.2 in
08
8 mm (0.31 in.)
04
40 mm
15
1.5 in
11
11 mm (0.43 in.)
05
50 mm
16
1.6 in
18
18 mm (0.71 in.)
07
70 mm
20
2.0 in
25
25.4 mm (1.00 in.)
09
90 mm
30
3.0 in
50
50 mm (1.97 in.)
12
120 mm
40
4.0 in
15
150 mm
50
5.0 in
60
6.0 in
Description
(1) When a body length of 12 is specified, the thread specification of
120 mm (1.2 in.) qualifies the length.
d
Unthreaded Length
Cable Length
Armored Cable Option
Code
Description
Code
Description
Code
00
Standard mount probes with a specified unthreaded length
are not available.
10
1.0 m (3.28 ft)
No armor
05
0.5 m (1.64 ft)
Armored cable
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
Description
1442 Eddy Current Probe Systems Specifications
Table 6 - Standard Mount 5 mm Probes with 1/4-28 UNF Thread and 1.0 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-0512E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 1.2 in. length
1442-PS-0512E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 1.2 in. length
1442-PS-0516E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 1.6 in. length
1442-PS-0516E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 1.6 in. length
1442-PS-0520E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 2 in. length
1442-PS-0520E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 2 in. length
1442-PS-0530E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 3 in. length
1442-PS-0530E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 3 in. length
1442-PS-0540E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 4 in. length
1442-PS-0540E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 4 in. length
1442-PS-0550E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 5 in. length
1442-PS-0550E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 5 in. length
1442-PS-0560E0010N
5 mm probe tip, standard cable, 1/4-28 UNF thread, 6 in. length
1442-PS-0560E0010A
5 mm probe tip, armored cable, 1/4-28 UNF thread, 6 in. length
Table 7 - Standard Mount 5 mm Probes with M8x1 Metric Thread and 1.0 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-0512M0010A
5 mm probe tip, armored cable, M8x1 thread, 120 mm length
1442-PS-0512M0010N
5 mm probe tip, standard cable, M8x1 thread, 120 mm length
1442-PS-0515M0010A
5 mm probe tip, armored cable, M8x1 thread, 150 mm length
1442-PS-0515M0010N
5 mm probe tip, standard cable, M8x1 thread, 150 mm length
1442-PS-0503M0010A
5 mm probe tip, armored cable, M8x1 thread, 150 mm length
1442-PS-0503M0010N
5 mm probe tip, standard cable, M8x1 thread, 150 mm length
1442-PS-0505M0010A
5 mm probe tip, armored cable, M8x1 thread, 50 mm length
1442-PS-0505M0010N
5 mm probe tip, standard cable, M8x1 thread, 50 mm length
1442-PS-0507M0010A
5 mm probe tip, armored cable, M8x1 thread, 70 mm length
1442-PS-0507M0010N
5 mm probe tip, standard cable, M8x1 thread, 70 mm length
1442-PS-0509M0010A
5 mm probe tip, armored cable, M8x1 thread, 90 mm length
1442-PS-0509M0010N
5 mm probe tip, standard cable, M8x1 thread, 90 mm length
Table 8 - Standard Mount 8 mm Probes with 3/8-24 UNF Thread and 1.0 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-0812E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 1.2 in. length
1442-PS-0812E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 1.2 in. length
1442-PS-0816E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 1.6 in. length
1442-PS-0816E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 1.6 in. length
1442-PS-0820E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 2 in. length
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Table 8 - Standard Mount 8 mm Probes with 3/8-24 UNF Thread and 1.0 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-0820E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 2 in. length
1442-PS-0830E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 3 in. length
1442-PS-0830E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 3 in. length
1442-PS-0840E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 4 in. length
1442-PS-0840E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 4 in. length
1442-PS-0850E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 5 in. length
1442-PS-0850E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 5 in. length
1442-PS-0860E0010A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 6 in. length
1442-PS-0860E0010N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 6 in. length
Table 9 - Standard Mount 8 mm Probes with 3/8-24 UNF Thread and 0.5 m (1.64 ft) Cable
Cat. No.
Description
1442-PS-0812E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 1.2 in. length
1442-PS-0812E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 1.2 in. length
1442-PS-0816E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 1.6 in. length
1442-PS-0816E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 1.6 in. length
1442-PS-0820E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 2 in. length
1442-PS-0820E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 2 in. length
1442-PS-0830E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 3 in. length
1442-PS-0830E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 3 in. length
1442-PS-0840E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 4 in. length
1442-PS-0840E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 4 in. length
1442-PS-0850E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 5 in. length
1442-PS-0850E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 5 in. length
1442-PS-0860E0005A
8 mm probe tip, armored cable, 3/8-24 UNF thread, 6 in. length
1442-PS-0860E0005N
8 mm probe tip, standard cable, 3/8-24 UNF thread, 6 in. length
Table 10 - Standard Mount 8 mm Probes with M10x1 Metric Thread with 1.0 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-0812M0010A
8 mm probe tip, armored cable, M10x1 thread, 120 mm length
1442-PS-0812M0010N
8 mm probe tip, standard cable, M10x1 thread, 120 mm length
1442-PS-0815M0010A
8 mm probe tip, armored cable, M10x1 thread, 150 mm length
1442-PS-0815M0010N
8 mm probe tip, standard cable, M10x1 thread, 150 mm length
1442-PS-0803M0010A
8 mm probe tip, armored cable, m10x1 thread, 30 mm length
1442-PS-0803M0010N
8 mm probe tip, standard cable, M10x1 thread, 30 mm length
1442-PS-0805M0010A
8 mm probe tip, armored cable, M10x1 thread, 50 mm length
1442-PS-0805M0010N
8 mm probe tip, standard cable, M10x1 thread, 50 mm length
1442-PS-0807M0010A
8 mm probe tip, armored cable, M10x1 thread, 70 mm length
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Table 10 - Standard Mount 8 mm Probes with M10x1 Metric Thread with 1.0 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-0807M0010N
8 mm probe tip, standard cable, M10x1 thread, 70 mm length
1442-PS-0809M0010A
8 mm probe tip, armored cable, M10x1 thread, 90 mm length
1442-PS-0809M0010N
8 mm probe tip, standard cable, m10x1 thread, 90 mm length
Table 11 - Standard Mount 8 mm Probes with M10x1 Metric Thread with 0.5 m (1.64 ft) Cable
Cat. No.
Description
1442-PS-0812M0005A
8 mm probe tip, armored cable, M10x1 thread, 120 mm length
1442-PS-0812M0005N
8 mm probe tip, standard cable, M10x1 thread, 120 mm length
1442-PS-0815M0005A
8 mm probe tip, armored cable, M10x1 thread, 150 mm length
1442-PS-0815M0005N
8 mm probe tip, standard cable, M10x1 thread, 150 mm length
1442-PS-0803M0005A
8 mm probe tip, armored cable, M10x1 thread, 30 mm length
1442-PS-0803M0005N
8 mm probe tip, standard cable, M10x1 thread, 30 mm length
1442-PS-0805M0005A
8 mm probe tip, armored cable, M10x1 thread, 50 mm length
1442-PS-0805M0005N
8 mm probe tip, standard cable, M10x1 thread, 50 mm length
1442-PS-0807M0005A
8 mm probe tip, armored cable, M10x1 thread, 70 mm length
1442-PS-0807M0005N
8 mm probe tip, standard cable, m10x1 thread, 70 mm length
1442-PS-0809M0005A
8 mm probe tip, armored cable, m10x1 thread, 90 mm length
1442-PS-0809M0005N
8 mm probe tip, standard cable, M10x1 thread, 90 mm length
Table 12 - Standard Mount 11 mm Probes with 1 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-1116E0510N
11 mm probe tip, standard cable, 1/2-20 UNF thread, 40 mm length
1442-PS-1116E0510A
11 mm probe tip, armored cable, 1/2-20 UNF thread, 40 mm length
1442-PS-1104M0510N
11 mm probe tip, standard cable, M14x1.5 thread, 40 mm length
1442-PS-1104M0510A
11 mm probe tip, armored cable, M14x1.5 thread, 40 mm length
Table 13 - Standard Mount 18 mm Probes with 1 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-1820E0510A
18 mm probe tip, armored cable, 7/8-14 UNF thread, 50 mm length
1442-PS-1805M0510A
18 mm probe tip, armored cable, M20x1.5 thread, 50 mm length
Table 14 - Standard Mount 25.4 mm Probes with 1 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-2520E0510A
25.4 mm probe tip, armored cable, 1 1/4-12 UNF thread, 50 mm length
1442-PS-2505M0510A
25.4 mm probe tip, armored cable, M30x1.5 thread, 50 mm length
1442-PS-2507N0010A
25.4 mm probe tip, armored cable, 4-M6 depth 14 thread, 76 mm length
10
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Table 15 - Standard Mount 50 mm Probes with 1 m (3.28 ft) Cable
Cat. No.
Description
1442-PS-5020E0010A
50 mm probe tip, armored cable 1-12 UNF thread, 50 mm length
1442-PS-5005M0010A
50 mm probe tip, armored cable, M24x1.5 thread, 50 mm length
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
11
1442 Eddy Current Probe Systems Specifications
1442 Series Reverse Mount Probes
08 30 M 05 05 N
1440-PR ------ ------ ----- ------ ------ ---a b c d e f
a
Probe Diameter
Body Length
Thread
Metric
Imperial
Code
Description
Code
Description
Code
Description
Code
Description
08
8 mm (0.31 in.)
03
30 mm
12
1.2 in.
Metric M10x1 thread
Imperial UNF thread 3/8-24
Unthreaded Length
Cable Length
Armored Cable Option
Code
Description
Code
Description
Code
Description
02
5.0 mm (0.2 in.)
05
0.5 m (1.64 ft)
No armor
05
5.0 mm (0.2 in.)
10
1.0 m (3.28 ft)
Armored cable
Table 16 - Reverse Mount Probes with M10x1 Metric Thread
Cat. No.
Description
1442-PR-0803M0505N
8 mm probe tip, 0.5 m (1.64 ft) integral cable, M10x1 thread, 30 mm length
1442-PR-0803M0510N
8 mm probe tip, 1.0 m (3.28 ft) integral cable, M10x1 thread, 30 mm length
Table 17 - Reverse Mount Probes with 3/8-24 UNF Thread
Cat. No.
Description
1442-PR-0812E0205N
8 mm probe tip, 0.5 m (1.64 ft) integral cable, 3/8-24 UNF thread, 1.2 in. length
1442-PR-0812E0210N
8 mm probe tip, 1.0 m (3.28 ft) integral cable, 3/8-24 UNF thread, 1.2 in. length
12
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
1442 Series Extension Cables
58 40 A
1442-EC- ------ ------ ---a b c
a
Probe Tip Diameter
Cable Length
Armored Cable Option
Code
Description
Code
Description
Code
Description
58
5 mm (0.20 in.) and
8 mm (0.31 in.)
40
4.0 m (13.12 ft)
No armor
45
4.5 m (14.76 ft)
Armored cable
11
11 mm (0.43 in.)
80
8.0 m (26.25 ft)
18
18 mm (0.71 in.)
85
8.5 m (27.89 ft)
25
25.4 mm (1.00 in.)
50
50 mm (1.97 in.)
Table 18 - Extension Cables for Use with 5 mm and 8 mm Probe Tips
Cat. No.
Description
1442-EC-5840N
4 m (13.12 ft) length
1442-EC-5840A
4 m (13.12 ft) length, armored
1442-EC-5845N
4.5 m (14.76 ft) length
1442-EC-5845A
4.5 m (14.76 ft) length, armored
1442-EC-5880N
8 m (26.25 ft) length
1442-EC-5880A
8 m (26.25 ft) length, armored
1442-EC-5885N
8.5 m (27.89 ft) length
1442-EC-5885A
8.5 m (27.89 ft) length, armored
Table 19 - Extension Cables for Use with 11 mm Probe Tips
Cat. No.
Description
1442-EC-1140N
4 m (13.12 ft) length
1442-EC-1140A
4 m (13.12 ft) length, armored
1442-EC-1180N
8 m (26.25 ft) length
1442-EC-1180A
8 m (26.25 ft) length, armored
Table 20 - Extension Cables for Use with 18 mm Probe Tips
Cat. No.
Description
1442-EC-1840A
4 m (13.12 ft) length, armored
1442-EC-1880A
8 m (26.25 ft) length, armored
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
13
1442 Eddy Current Probe Systems Specifications
Table 21 - Extension Cables for Use with 25.4 mm Probe Tips
Cat. No.
Description
1442-EC-2540A
4 m (13.12 ft) length, armored
1442-EC-2580A
8 m (26.25 ft) length, armored
Table 22 - Extension Cables for Use with 50mm Probe Tips
Cat. No.
Description
1442-EC-5040A
4 m (13.12 ft) length, armored
1442-EC-5080A
8 m (26.25 ft) length, armored
14
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
1442 Series Probe Drivers
58 50
1442-DR- ------ -----a b
a
Probe Tip Diameter
System Length
Code
Description
Code
Description
58
5 mm (0.20 in.) and
8 mm (0.31 in.)
50
5.0 m (16.40 ft)
11
11 mm (0.43 in.)
90
9.0 m (29.53 ft)
18
18 mm (0.71 in.)
25
25.4 mm (1.00 in.)
50
50 mm (1.97 in.)
The sensor cable length and the extension cable length, when added together, must equal the probe
system total length.
Sensor Cable Length + Extension Cable Length = System Length
See the following table for examples.
IMPORTANT
Sensor
Extension Cable
Driver(1)
System Cable Length
0.5 m (1.64 ft)
4.5 m (14.76 ft)
5.0 m (16.40 ft)
1442-DR-xx50
1.0 m (3.28 ft)
4.0 m (13.12 ft)
5.0 m (16.40 ft)
1442-DR-xx50
0.5 m (1.64 ft)
8.5 m (27.89 ft)
9.0 m (29.53 ft)
1442-DR-xx90
1.0 m (3.28 ft)
8.0 m (26.25 ft)
9.0 m (29.53 ft)
1442-DR-xx90
(1) Where xx= appropriate code for probe size.
Table 23 - Probe Drivers for Use with 5 mm and 8 mm Probe Tips
Cat. No.
Description
1442-DR-5850
Use with 5 m (16.40 ft) total length systems
1442-DR-5890
Use with 9 m (29.53 ft) total length systems
Table 24 - Probe Drivers for Use with 11 mm Probe Tips
Cat. No.
Description
1442-DR-1150
Use with 5 m (16.40 ft) total length systems
1442-DR-1190
Use with 9 m (29.53 ft) total length systems
Table 25 - Probe Drivers for Use with 18 mm Probe Tips
Cat. No.
Description
1442-DR-1850
Use with 5 m (16.40 ft) total length systems
1442-DR-1890
Use with 9 m (29.53 ft) total length systems
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
15
1442 Eddy Current Probe Systems Specifications
Table 26 - Probe Drivers for Use with 25.4 mm Probe Tips
Cat. No.
Description
1442-DR-2550
Use with 5 m (16.40 ft) total length systems
1442-DR-2590
Use with 9 m (29.53 ft) total length systems
Table 27 - Probe Drivers for Use with 50 mm Probe Tips
Cat. No.
Description
1442-DR-5050
Use with 5 m (16.40 ft) total length systems
1442-DR-5090
Use with 9 m (29.53 ft) total length systems
16
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Accessories
The following accessories are available.
Cat. No.
Description
EK-15629
Cam (valve) position detector rotary potentiometer
EK-44395
Hall-effect speed sensor, magnetic, zero velocity
EK-47774
4.88 m (16 ft) connector cable for hall-effect speed sensor
Rotary Potentiometer
The rotary potentiometer is used to provide accurate measures of governor valve, cams, and gear positions as part of a
turbine-generator supervisory instrumentation system.
Catalog number EK-15629 is a direct replacement for GE catalog number 9888323 or equivalent cam position detectors.
The potentiometer operates over a full 360 mechanical (300 electrical) range. The arm of the detector rotates in either
direction and can be mounted at either end of the cam.
Attribute
Rotary Potentiometer
Input signals, max
3-wire, 028V AC or DC, 0.42 A
Range
360 mechanical, 300 electrical
Dimensions, approx
152 mm (6 in.) diameter body
9.5 mm (3/8 in.) diameter shaft
51 mm (2 in.) extension
Terminals
Screw
Resistance
1400
Installation
Replacement for GE 9888323 or equivalent,
Two mounting holes on two 60.3 mm (3/8 in.) centers
-20 UNF thread
Weight
2.27 kg (5 lb)
Construction
Ceramic body, wire-wound steel mounting bracket and aluminum shaft
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
17
1442 Eddy Current Probe Systems Specifications
Hall-effect Speed Sensor
Catalog number EK-44395 is an Airpax Model H1512-005 hall-effect sensor designed to generate a steady pulse train in
response to movement of a target surface.
Cat. No.
Description
EK-44395
Hall-effect speed sensor, magnetic, zero velocity
EK-47774
4.88 m (16 ft) connector cable for hall-effect speed sensor
Attribute
Hall-effect Speed Sensor
Frequency range
Near 015 kHz
Power supply voltage
4.524V DC
Reverse voltage protection
Up to -30V DC
Temperature range
-40125 C (-40257 F)
TTL compatible logic
50% 30% duty cycle
Housing material
300 series stainless steel
Target air gap
0.0050.020 in. (01.270.508 mm) with 20 diametric pitch gear
0.0050.045 in. (01.271.143 mm) with 12 diametric pitch gear
0.0050.060 in. (01.271.524 mm) with 8 diametric pitch gear
18
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
1442 Eddy Current Probe Systems Specifications
Notes:
Rockwell Automation Publication 1442-TD001D-EN-P - February 2014
19
Important User Information
Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety
Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from
your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some
important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference,
and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment
must satisfy themselves that each intended application of this equipment is acceptable.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the
use or application of this equipment.
The examples and diagrams in this publication are included solely for illustrative purposes. Because of the many variables
and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this
document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.
Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6 34752 erenky, stanbul, Tel: +90 (216) 5698400
Publication 1442-TD001D-EN-P - February 2014
Supersedes Publication 1442-TD001C-EN-P - January 2013
Copyright 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.