CYME
Power Engineering Software and Solutions
Power Cable
Ampacity Rating
Calculate ampacity and temperature
rise of power cable installations.
The CYMCAP software
is dedicated to the
calculation of ampacity
and temperature rise
calculations for power
cable installations. The
accuracy of the software
provides increased
confidence when
upgrading power cable
installations and designing
new ones; maximizing
the benefits from the
considerable capital
investment associated
with them. It also helps
increase system reliability
and supports the proper
utilization of the installed
equipment.
The CYMCAP software is
dedicated to performing
ampacity and temperature rise
calculations for power cable
installations. Determining the
maximum current power cables
can sustain without deterioration
of any of their electrical
properties is important for the
design of electrical installations.
It addresses steady-state and
transient thermal cable rating
as per the analytical techniques
described by Neher-McGrath and
the International Standards IEC
287 and IEC 853.
This software was developed
jointly by Ontario Hydro (Hydro
One), McMaster University
and CYME International, under
the auspices of the Canadian
Electricity Association.
The validation of the results
obtained with the CYMCAP
software provides increased
confidence when upgrading
existing power cable installations
and designing new ones,
thus maximizing the benefits
from the considerable capital
investment associated with
them.
Power Cable
Ampacity
Rating
Simulate the thermal
behavior of power cable
installations.
Analytical Capabilities
Iterative techniques based on
Neher-McGrath and IEC-287
methods
Full compliance with
North American practice
and compliance with IEC
standards IEC 60287, IEC
60228, IEC 60853, etc.
Detailed graphical
representation of virtually
any type of power cable. This
functionality can be used to
modify existing cables data
and enrich the cable library
with new ones. This includes
single-core, three-core,
belted, pipe-type, submarine,
sheathed, and armored cables
Different cable installation
conditions such as directly
buried, thermal backfill,
underground ducts or duct
banks
Pipe-type cables directly
buried or in thermal backfill
Independent libraries and
databases for cables, ductbanks, load curves, heat
sources and installations
Modeling of cables in air on
riser poles, groups of cables in
air, moisture migration, nearby
heat sources and heat sinks,
etc.
Different cable types within
one installation
Non-isothermal earth surface
modeling
Cyclic loading patterns as per
IEC-60853, including soil
dry out
Multiple cables per phase
with accurate modeling of the
sheath mutual inductances
which greatly influence
circulating current losses and
thus de-rates the ampacity of
cables
All types of sheath bonding
arrangements for flat and
triangular formations are
supported with explicit
modeling of minor section
lengths, unequal cable
spacing, etc.
Transient Analysis
The program includes a Transient
Thermal Analysis feature which
includes the following:
Ampacity given time and
temperature
Temperature analysis given
time and ampacity
Time to reach a given
temperature, given the
ampacity
Ampacity and temperature
analysis as a function of time
User-defined load profiles per
circuit
Multiple cables per installation
Circuits can be loaded
simultaneously or one at a
time
Cables on Riser Poles
Heat Source and Heat Sink
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
[Link]
CYME International T&D
1485 Roberval, Suite 104
[Link], QC, Canada J3V 3P8
P: 450.461.3655
F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@[Link]
[Link]
2014 Eaton
All Rights Reserved
Printed in Canada
[Link]. BR 917 028 EN November 2014