PROJECT: IOCL KOLKATA LOBP
DESIGN CHECK FOR T-0622
4T Dosing Vessel 2
CODE: ASME SECTION VIII DIV.1 2015
Wall
SHELL
Static (Water)head height 1650 mm
Pressure due to liquid head 16.19 Kpa
P = Internal design pressure 0 Kpa
R = Inside Radius of Shell
consideration, 1000 mm
S = Maximum allowable stress value 115 N/mm2
E = Joint efficiency 0.85
CA =Corrosion allowance 0 mm
t = minimum required thickness of shell
t = minimum required thickness of shell 0.1656072467 mm
Note: The thickness required was less than the Code Minimum,
therefore the Code Minimum value of 1.5000 mm. per UG-16 will be
used
Wall Thickness Calculation Check
CONICAL BOTTOM CIR
Static (Water)head height 2131 mm Static (Water)head heig
Pressure due to liquid head 20.91 Kpa Pressure due to liquid h
cone
69.775139 deg C = Factor
(apex) angle of the cone
0.3457027123 rad d= diameter
D= Inside dia.of conical head 2100 mm
t = minimum required thickness of cone t = minimum require
t = minimum required thickness of cone 0.6496477437 mm t = minimum require
Note: The thickness required was less than the Code Minimum, therefore the Note: The thickness req
Code Minimum value of 1.5000 mm. per UG-16 will be used therefore the Code Mini
used
CIRCULAR FLAT HEAD
atic (Water)head height 2131 mm
essure due to liquid head 20.91 Kpa
= Factor 0.2
= diameter 200 mm
= minimum required thickness of Flat head
= minimum required thickness of flat hea 1.308015 mm
ote: The thickness required was less than the Code Minimum,
erefore the Code Minimum value of 1.5000 mm. per UG-16 will be
sed
Half pipe Jacket Design Check per Non
K-Factor = 74.32 Refer FIG. EE - 2 and EE - 3 of APPENDIX EE
P1 Jacket Pressure = 999.942 Kpa
Half-Pipe Jacket Thickness 4 mm
r =Inside radius of
jacket defined in Fig. EE- 40.5 mm
S1 = allowable tensile stress
of jacket material at design 86.9 N/mm2
temperature
Req'd Half-Pipe Jacket Thickness per App. EE-1, Eqn. (2)
Tj = 0.552756
Minimum Fillet Weld Size (Based on Jacket Thickness)
Tj*1.414 = 5.656 mm
gn Check per NonMandatory Appendix EE
STEP 1: The required thickness of the shell due to internal pressure is
calculated from eq. (1) of UG-27 a
t= 0.1656072467
STEP 2: Selected Shell thickness 8 mm
STEP 3: Longitudinal Stress in Shell due to Internal Pressure
S' = 1.01165625 N/mm2
STEP 4: Permissible Jacket Pressure per Appendix EE-1, Equation (1)
P'= 2.307432 N/mm2
P' = 2307.432 Kpa
STEP 5: Jacket Pressure VS Permissible Jacket Pressure
Design is adequate
DESIGN NOTES:
1) The minimum thickness permitted for shells and heads, after forming and regardless of pro
ng and regardless of product form and material, shall be 1/16 in. (1.5 mm) exclusive of any corrosion allowance
any corrosion allowance