First of all, we have to create the geometry.
This time a simple frame case
Define load patterns
Define just live and dead action without the seismic action becaue we will
work with it
Now assign al vertical loads
Now we have to explicitly assign the mass corresponding to the structure
(on the middle of each storey). We assume a rigid diaphragm on each slab.
Now well create a grid line on the middle
Create three reference points
Assign the masses now
Now assign the rigid diaphragm
Select the five joints of the floor-
Repeat the process for the nest two
floors
E poi, possiamo runare! Now, the modal analysis is finished
And we use the response spectrum
In the case of Eurocode
Add load cases (scale factor is the gravity acceleration)
Envelope: Comb1 - s. f. 1 Comb2- s. f. 1
FOR THE NEW 3D BUILDING
We need to assign mass to 3 dof this time (x, y being equal to the mass of
the story - and rotational mass on z to be computed)
W1 = Gk + Qk
W1 = (7+0.15*2)27.5*20 = 4015 kN -> mass M=404.5 Ton
W2 = (7+0.15*2)27.5*20 = 4015 kN -> mass M=404.5 Ton
W3 = (7+0.30*2)27.5*20 = 4180 kN -> mass M=418.0 Ton
These are the values for translational mass equal on x and y
For finding the rotational mass
1
RM 1= M ( L2x + L2y ) =0.3401.5 ( 27.52 +202 ) =38686Tn
12
1
RM R= M ( L2x + L2y ) =0.3418.0 ( 27.52 +202 )=40276 Tn
12
Direction of the slab: vertical
Tributary area:
For the permanent load: 7 kN/m*5m = 35 kN/m on the middle and the half
on the sides 17.5 Kn/M
For the variable load: 2 kN/m*5m = 10 kN/m on the middle and the half on
the sides 5 Kn/M
Assign loads
Computation of the internal actions-Second part, design and check.
Definition of the response spectrum
Peak
site
acceleration depends on the region and it is given by the code in function of
the classification of the concrete. Given in terms of g-> gravity acceleration.
Ground type depends on the geotechnical investigation. Behavior factor is
given by moment resisting frame, multistoried and multibays. q o=4.5 times
1.3. High ductility class and it is regular. This is the design response
spectrum (Divided by the behavior factor).
Now we should define the load case Define-load cases-add new load case
And repeat the procedure for the orthogonal direction. (selecting u2 this
time)
Define- Load combinations Add new
Now for the seismic actions. It is a residential building and the scale factor is
given by the code as 0.3
Sap considers the positive and negative directions, so there is no need to
introduce more combinations. We should just to provide the envelope.
Shear should be always prevented because it is a brittle failure.
Insert now a shear wall. Edit-Edit frames-divide. Into 4.
Define-
sections properties-area sections
Edit-areaa-divide areas. Into four, so we can make them coincide with the
columns and beams.
Define-groups-new group. (GW1) group wall 1.
Select all the elements on the base, then go to assign to group.
Define-section cuts add section cut and then select the group created.
Display-tables