Maximize your ROI
Conext CL-60 String Inverter
The ideal solution for decentralized
power plants and large commercial
buildings.
Higher return on investment
Integrated wiring box reduces your CAPEX
String monitoring included
Solution at a glance 66/63.4 kW continuous active power1 reduces
total inverters per MW
Designed for reliability
Robust design through rigorous Multiple
Environmental Over Stress Testing (MEOST),
It increases energy generation and reduces both CAPEX Highly Accelerated Life Test (HALT) and
and OPEX. Along with Schneider Electrics rigorous Temperature Humidity and Bias testing (THB)
reliability procedures, the Conext CL-60 is guaranteed for D
long-term and superior reliability. environments
Ease of installation and service
The Conext CL-60 is the ideal choice for decentralized Pre-wired PV quick connectors
power plants and large commercial projects. It is built for Z
distributed power generation architecture and compatible Solution to support grid connectivity
with a broad range of Schneider Electric MV products. Broad range of MV products to provide you with a
We provide a complete system solution for peace of total solution
mind. Embedded grid management features
Distributed power generation Large commercial rooftops
PRELIMINARY
solar.schneider-electric.com | 2
Higher power and all-inclusive design to reduce your CAPEX
Device short name CL-60E (IEC Standard) CL-60A (North America Standard)
DC Side
DC max. input voltage 1000V 1000V
DC full power MPPT voltage range (PF=1) 570 - 850 V 550 - 850 V
DC operating voltage range at nominal AC voltage 570 - 950 V 550 - 950 V
DC start voltage at nominal AC voltage 620 V 620 V
DC max. array short circuit current 140 A 140 A
DC max. PV operating current 120 A 120 A
1 / 8 (Y connector recommended for up to
Number of MPPT / max. number of inputs per MPPT 1 / 14
14 strings)
DC connectors / DC max. current per input MC4 / 12 A (mating part included) Amphenol H4 /25 A (mating part included)
DC fuses (included) 14 pairs (+), string monitoring included 8 pairs (+/-), string monitoring included
DC switch / DC SPD / AFD Yes / Type II surge arrester / Null Yes / Type II surge arrester / Yes
AC Side
AC max. output power1 66 kW 63.4 kW
AC max. continuous apparent power (at nominal AC voltage) 66 kVA 63.4 kVA
AC nominal output voltage / AC operating voltage range 400 V / 310 480 V 380 V / 295 - 456V
AC nominal frequency / Frequency range 50 Hz and 60 Hz / 45-55 Hz and 55-65 Hz 60 Hz / 55-65 Hz
AC max. continuous output current 96 A 96 A
Power factor range 0.8 lead to 0.8 lag adjustable 0.8 lead to 0.8 lag adjustable
THD at max. power < 3% <3%
Screw clamp terminal, AL or CU type cable Screw clamp terminal, AL or CU type cable
AC terminal
compatible compatible
AC disconnect Not included Included
AC connection 4 wire grounded WYE and ungrounded DELTA 4 wire grounded WYE and ungrounded DELTA
98. 7% / 98. 5% 98. 7% / 98. 0%
Power consumption at nighttime < 1W <1W
Enclosure type protection class IP 65 Type 4X
Weight 66 kg. 147 lb.
Inverter dimensions (H x W x D) 95.8 x 65.2 x 25.0 cm 38.9 x 25.7 x 9.8 in
2 2
Ambient air temperature for operation -25C to 60C -13F to 140F
Max. operating altitude 4000 m, derating > 3000 m 13123 ft, derating > 9842 ft
Relative humidity % 0100% condensing 0100% condensing
Audible noise 55 dBA +/- 3 dBA 55 dBA +/- 3 dBA
Inverter mounting
User interface and communications
User interface
RS485-Modbus, Modbus-TCP (Daisy chain capability for both: Modbus RS485 Serial
Communication interface
or Modbus TCP over Ethernet). Communication protocol - SunSpec compatible & certified
Regulatory approval
IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, FCC Class B, UL 1741-2nd edition,
EN 61000-6-3, IEC 61683, EN 50530, CSA C22.2 107.1, CEC efficiency standard, UL1699B
and Environmental standard3
IEC 60068-2-1,2,14,30, EN 60529
3 VDE-0126-1-1, UTE C15-712-1, VDE-AR-N 4105, IEEE 1547, IEEE 1547.1
BDEW, IEC 61727, IEC 62116, G59/3, PEA, MEA
Environmental RoHS, REACH RoHS
1
Maximum active power output at rated AC output voltage, unity power factor, full DC power input and within full power ambient temperature range. Please refer to the derating curve in Owners Guide.
2
Refer to Owners Guide for more details.
3
2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its a liated companies.
All information is preliminary and will need to be con rmed at the time of order.