0% found this document useful (1 vote)
379 views24 pages

Footing Design Calculations and Analysis

This document provides design details for footing C2 that will support a column measuring 0.23m x 0.3m under an axial load of 330 kN. The footing size is calculated as 2.2m x 2.2m with a depth of 0.45m. Reinforcement of 12mm diameter bars at 150mm centers is designed to resist the calculated bending moment of 41.26 kNm. Shear stress is checked to be within allowable limits.

Uploaded by

samirbendre1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
379 views24 pages

Footing Design Calculations and Analysis

This document provides design details for footing C2 that will support a column measuring 0.23m x 0.3m under an axial load of 330 kN. The footing size is calculated as 2.2m x 2.2m with a depth of 0.45m. Reinforcement of 12mm diameter bars at 150mm centers is designed to resist the calculated bending moment of 41.26 kNm. Shear stress is checked to be within allowable limits.

Uploaded by

samirbendre1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Design of footing C1 (INSERT VALUES IN YELLOW CELLS O

Input data B(m) d(m)


Size of column(m)= 0.23 0.23
Axial load (Pu) = 225.00 KN
SBC (Safe bearing capacity) = 65 KN/sq.m
SBC (In case of moment) = 65 KN/sq.m
Fck = 25 N/sq.mm
Fy = 415 N/sq.mm
Moment (Mu) = 0.00 Knm
`

Loading Calculation

Working load = 150.00 KN


Self weight 15.00 KN
Total Working load = 165.00 KN
Working Moment = 0.00 KN

Size of footing

Area of footing = 2.54 sq.m


Area of footing = 2.54 sq.m (In case moment is considered increase area of footing
Total = 5.08 sq.m
B (m) D (m)
Provide area of footing = 1.75 1.75
3.0625

Calculation of upward pressure

Direct pressure (By axial load) = 58.98 KN/sq.m

Bending pressure = M/Z


(M) Moment about X axis (working) = 0.00 Knm
(Z) Section modulus = 0.89 cu.m

Bending pressure (M/Z) = 0.00 KN/sq.m

Maximum pressure = (Direct pressure + Bending pressure)


Maximum pressure = 58.98 OK (Max pressure should be less than SBC)

Minimum pressure = (Direct pressure - Bending pressure)


Minimum pressure = 58.98 OK (Minimum pressure should be greater than 0

Net upward limiting pressure(limiting) = 88.47 KN/sq.m


Consider Width for calculation(b) = 1m
Thus, Net upward limiting pressure(limiting) = 88.47 KN/m

Thickness of footing
Cantilever portion of footing =
Design B.M. (Mu) = 25.55 Knm

Eff. Depth of footing(d) = 86.06 mm

Total depth of foundation (D)= 136.06 mm

Total depth of foundation (D)= 400.00 mm 0.4 m


Eff. Depth of footing(d) = 350.00 mm
0.35 mm

Calculation of reinforcement

Design B.M. (Mu) = 25.55 Knm


b= 1000 mm
d= 350.00 mm

Ast req = 204.27 sq.mm/m

Min. Ast = 0.12%b*D


Ast min = 480 sq.mm

Consider Diameter Of Bar = 12 mm

Spacing required = 235.50 mm


Spacing provided = 150.00 mm

Thus, Provide 12 mm Dia. Bar at 150 mm c/c

Ast provided = 753.60 sq.mm/m

% provided = 0.19 %

Check for Shear Stress

Considering one way shear

Limiting pressure = 88.47 KN/sq.m


Cantilever portion = 0.76 m
Eff. Depth (d) = 0.35 m 0.76
Critical Area = 0.7175 sq.mm

Critical shear force(Tauv) = Limiting pressure * Critical Area


= 63.48 KN
1m
For % reinf. = 0.19 %
From Table 19; pg 73; IS 456

Design Shear strength (Tauc) = 0.29 mpa


Max Shear Strength (Tcmax) = 3.1 mpa

Nominal Shear Strength (Tauv) = 0.24 mpa


Safe

Considering two way shear (Punching shear)

Limiting pressure = 88.47 KN/sq.m


Cantilever portion = 0.76 m
Eff. Depth (d) = 0.35 m
Critical Area = 1.83 sq.mm
Critical Peri. (bo) = 4.44 m
Width (b) = 1.75 m

Critical shear force(Tauv) = Limiting pressure * Critical Area


= 161.93 KN

Permissible shear stress for two way shear should not exceed
Ks*Tauc
where Ks = 0.5+ Bc
Bc = Short side of collumn/Long side of collumn
Bc = 1

Ks = 1.5
Taking Ks = 1 (Value of Ks should not be less than 1)

Tauc= 1.25 mpa

Design Shear Stress(Ks*Tauc)= 1.25 mpa

Nominal Shear Strength (Tauv) = 0.02 mpa


Safe

230 mm
pier
2 :1

400
mm
1750 mm

1750 mm

1750
mm

12

12
(INSERT VALUES IN YELLOW CELLS ONLY)

1.75 1.75 0.4


12 150.00

(In case moment is considered increase area of footing by 15%)

(Max pressure should be less than SBC)

(Minimum pressure should be greater than 0)


0.76 m on both side

0.038
0.962
0.019
204.27

d
1m
1.75

1.75

Critical area

1.75
critial area

d/2

1.75
mm

mm
Design of footing C2 (INSERT VALUES IN YELLOW CELLS O

Input data B(m) d(m)


Size of column(m)= 0.23 0.3
Axial load (Pu) = 330.00 KN
SBC (Safe bearing capacity) = 65 KN/sq.m
SBC (In case of moment) = 65 KN/sq.m
Fck = 25 N/sq.mm
Fy = 415 N/sq.mm
Moment (Mu) = 0.00 Knm
`

Loading Calculation

Working load = 220.00 KN


Self weight 22.00 KN
Total Working load = 242.00 KN
Working Moment = 0.00 KN

Size of footing

Area of footing = 3.72 sq.m


Area of footing = 3.72 sq.m (In case moment is considered increase area of footing
Total = 7.45 sq.m
B (m) D (m)
Provide area of footing = 2.2 2.2
4.84

Calculation of upward pressure

Direct pressure (By axial load) = 56.70 KN/sq.m

Bending pressure = M/Z


(M) Moment about X axis (working) = 0.00 Knm
(Z) Section modulus = 1.77 cu.m

Bending pressure (M/Z) = 0.00 KN/sq.m

Maximum pressure = (Direct pressure + Bending pressure)


Maximum pressure = 56.70 OK (Max pressure should be less than SBC)

Minimum pressure = (Direct pressure - Bending pressure)


Minimum pressure = 56.70 OK (Minimum pressure should be greater than 0

Net upward limiting pressure(limiting) = 85.06 KN/sq.m


Consider Width for calculation(b) = 1m
Thus, Net upward limiting pressure(limiting) = 85.06 KN/m

Thickness of footing
Cantilever portion of footing =
Design B.M. (Mu) = 41.26 Knm

Eff. Depth of footing(d) = 109.36 mm

Total depth of foundation (D)= 159.36 mm

Total depth of foundation (D)= 450.00 mm 0.45 m


Eff. Depth of footing(d) = 400.00 mm
0.40 mm

Calculation of reinforcement

Design B.M. (Mu) = 41.26 Knm


b= 1000 mm
d= 400.00 mm

Ast req = 289.33 sq.mm/m

Min. Ast = 0.12%b*D


Ast min = 540 sq.mm

Consider Diameter Of Bar = 12 mm

Spacing required = 209.33 mm


Spacing provided = 150.00 mm

Thus, Provide 12 mm Dia. Bar at 150 mm c/c

Ast provided = 753.60 sq.mm/m

% provided = 0.17 %

Check for Shear Stress

Considering one way shear

Limiting pressure = 85.06 KN/sq.m


Cantilever portion = 0.985 m
Eff. Depth (d) = 0.40 m 0.985
Critical Area = 1.287 sq.mm

Critical shear force(Tauv) = Limiting pressure * Critical Area


= 109.47 KN
1m
For % reinf. = 0.17 %
From Table 19; pg 73; IS 456

Design Shear strength (Tauc) = 0.29 mpa


Max Shear Strength (Tcmax) = 3.1 mpa

Nominal Shear Strength (Tauv) = 0.28 mpa


Safe

Considering two way shear (Punching shear)

Limiting pressure = 85.06 KN/sq.m


Cantilever portion = 0.985 m
Eff. Depth (d) = 0.40 m
Critical Area = 2.92 sq.mm
Critical Peri. (bo) = 5.54 m
Width (b) = 2.2 m

Critical shear force(Tauv) = Limiting pressure * Critical Area


= 248.52 KN

Permissible shear stress for two way shear should not exceed
Ks*Tauc
where Ks = 0.5+ Bc
Bc = Short side of collumn/Long side of collumn
Bc = 0.7666667

Ks = 1.2666667
Taking Ks = 1 (Value of Ks should not be less than 1)

Tauc= 1.25 mpa

Design Shear Stress(Ks*Tauc)= 1.25 mpa

Nominal Shear Strength (Tauv) = 0.02 mpa


Safe

230 mm
pier
2 :1

450
mm
2200 mm

2200 mm

2200
mm

12

12
(INSERT VALUES IN YELLOW CELLS ONLY)

2.2 2.2 0.45


12 150.00

(In case moment is considered increase area of footing by 15%)

(Max pressure should be less than SBC)

(Minimum pressure should be greater than 0)


0.985 m on both side

0.047
0.953
0.024
289.33

d
2.2
1m

2.2

Critical area

2.2
critial area

d/2

2.2
mm

mm
Design of footing C3 (INSERT VALUES IN YELLOW CELLS O

Input data B(m) d(m)


Size of column(m)= 3.9 3.6
Axial load (Pu) = 3600.00 KN
SBC (Safe bearing capacity) = 65 KN/sq.m
SBC (In case of moment) = 65 KN/sq.m
Fck = 25 N/sq.mm
Fy = 415 N/sq.mm
Moment (Mu) = 0.00 Knm
`

Loading Calculation

Working load = 2400.00 KN


Self weight 240.00 KN
Total Working load = 2640.00 KN
Working Moment = 0.00 KN

Size of footing

Area of footing = 40.62 sq.m


Area of footing = 40.62 sq.m (In case moment is considered increase area of footing
Total = 81.23 sq.m
B (m) D (m)
Provide area of footing = 6.7 6.4
42.88

Calculation of upward pressure

Direct pressure (By axial load) = 67.22 KN/sq.m

Bending pressure = M/Z


(M) Moment about X axis (working) = 0.00 Knm
(Z) Section modulus = 45.74 cu.m

Bending pressure (M/Z) = 0.00 KN/sq.m

Maximum pressure = (Direct pressure + Bending pressure)


Maximum pressure = 67.22 REVISE (Max pressure should be less than SBC)

Minimum pressure = (Direct pressure - Bending pressure)


Minimum pressure = 67.22 OK (Minimum pressure should be greater than 0

Net upward limiting pressure(limiting) = 100.83 KN/sq.m


Consider Width for calculation(b) = 1m
Thus, Net upward limiting pressure(limiting) = 100.83 KN/m

Thickness of footing
Cantilever portion of footing =
Design B.M. (Mu) = 98.81 Knm

Eff. Depth of footing(d) = 169.24 mm

Total depth of foundation (D)= 219.24 mm

Total depth of foundation (D)= 450.00 mm 0.45 m


Eff. Depth of footing(d) = 400.00 mm
0.40 mm

Calculation of reinforcement

Design B.M. (Mu) = 98.81 Knm


b= 1000 mm
d= 400.00 mm

Ast req = 705.19 sq.mm/m

Min. Ast = 0.12%b*D


Ast min = 540 sq.mm

Consider Diameter Of Bar = 16 mm

Spacing required = 372.15 mm


Spacing provided = 150.00 mm

Thus, Provide 16 mm Dia. Bar at 150 mm c/c

Ast provided = 1339.73 sq.mm/m

% provided = 0.30 %

Check for Shear Stress

Considering one way shear

Limiting pressure = 100.83 KN/sq.m


Cantilever portion = 1.4 m
Eff. Depth (d) = 0.40 m 1.4
Critical Area = 6.7 sq.mm

Critical shear force(Tauv) = Limiting pressure * Critical Area


= 675.56 KN
1m
For % reinf. = 0.30 %
From Table 19; pg 73; IS 456

Design Shear strength (Tauc) = 0.29 mpa


Max Shear Strength (Tcmax) = 3.1 mpa

Nominal Shear Strength (Tauv) = 1.21 mpa


Safe

Considering two way shear (Punching shear)

Limiting pressure = 100.83 KN/sq.m


Cantilever portion = 1.4 m
Eff. Depth (d) = 0.40 m
Critical Area = 39.64 sq.mm
Critical Peri. (bo) = 7.2 m
Width (b) = 6.7 m

Critical shear force(Tauv) = Limiting pressure * Critical Area


= 3996.91 KN

Permissible shear stress for two way shear should not exceed
Ks*Tauc
where Ks = 0.5+ Bc
Bc = Short side of collumn/Long side of collumn
Bc = 1.0833333

Ks = 1.5833333
Taking Ks = 1 (Value of Ks should not be less than 1)

Tauc= 1.25 mpa

Design Shear Stress(Ks*Tauc)= 1.25 mpa

Nominal Shear Strength (Tauv) = 0.08 mpa


Safe

3900 mm
pier
2 :1

450
mm
6700 mm

6700 mm

6400
mm

16

16
(INSERT VALUES IN YELLOW CELLS ONLY)

6.7 6.4 0.45


16 150.00

(In case moment is considered increase area of footing by 15%)

(Max pressure should be less than SBC)

(Minimum pressure should be greater than 0)


1.4 m on both side

0.114
0.886
0.059
705.19

d
1m
6.7

6.4

Critical area

6.4
critial area

d/2

6.7
mm

mm

Design of footing C1
(INSERT VALUES IN YELLOW CELLS O
Input data
B(m)
d(m)
Size of column(m)= 
0.23
0.23
Axial load  (Pu) =
2
Consider Width for calculation(b) = 
1 m
Thus, Net upward limiting pressure(limiting) = 
88.47 KN/m
Thickness of footing
Cant
=
63.48 KN
For % reinf. =
0.19 %
From Table 19; pg 73; IS 456
Design Shear strength (Tauc) =
0.29 mpa
Max Shear Strength (Tc
1750 mm
1750 mm
1750
mm
12
12
(INSERT VALUES IN YELLOW CELLS ONLY)
1.75
1.75
0.4
12
150.00
(In case moment is considered increase area of footing by 15%)
(
0.76 m on both side
0.038
0.962
0.019
204.27
d
1.75
1.75
Critical area
1.75
critial area
d/2
1.75
1m
mm
mm
Design of footing C2
(INSERT VALUES IN YELLOW CELLS O
Input data
B(m)
d(m)
Size of column(m)= 
0.23
0.3
Axial load  (Pu) =
33
Consider Width for calculation(b) = 
1 m
Thus, Net upward limiting pressure(limiting) = 
85.06 KN/m
Thickness of footing
Cant

You might also like