0% found this document useful (0 votes)
109 views2 pages

Digester Volume Calculation Guide

The document calculates the required digester volume and dimensions based on retention time and input per day at different temperatures. It determines that at 100C with a retention time of 55 days and daily input of 20L, the required volume is 1.1m3 and the diameter and height are 0.65m and 3.3m respectively. Similarly, it calculates the diameter and height for 200C and 300C temperatures based on given retention times and daily inputs.

Uploaded by

Sai Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views2 pages

Digester Volume Calculation Guide

The document calculates the required digester volume and dimensions based on retention time and input per day at different temperatures. It determines that at 100C with a retention time of 55 days and daily input of 20L, the required volume is 1.1m3 and the diameter and height are 0.65m and 3.3m respectively. Similarly, it calculates the diameter and height for 200C and 300C temperatures based on given retention times and daily inputs.

Uploaded by

Sai Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

14380-09-34P AID: 34788 | 12/08/2017

Calculate the required digester volume based on the retention time

At T=100C ,Retention time (days) recommended 55days and Input per day is 20L( From
Given Table)

L 1m3
Vt = 20 55days 1.1m3
day 1000 L
1m3 =1000Litres

Substitute the digester dimensions have a 1:5 diameter to height ratio i.e H=5D.

Volume = Area Height

D2
Area of digester =
4
Height = 5D
D2
V Height
4
D2
5D
4
5 D 3
V
4
4 V
D 3
5

Here D =Diameter of digester


h = Height of digester
V= Volume of digester

4V 3 4 1.1
Dt 100 C 3 0.65m
5 5

h t =100 C =5D=50.65 m = 3.3m

At T=200C Retention time (days) recommended is 20days and Input per day is 20L
(From Given Table)

L 1m3
Vt =20 20days =0.4m3
day 1000 L
Volume = Area Height

D2
Area of digester =
4

Height = 5D
D2
V Height
4
D2
5D
4
5 D 3
V
4
4 V
D 3
5

4V 3 4 0.4
Dt 200 C 3 0.47m
5 5
h t = 200 C =5D=50.47 m = 2.3m
At T=300C Retention time (days) recommended 8days and Input per day is 20L (From
Given Table)
L 1m3
Vt 30 C 20
0
8days 0.16 m3
day 1000 L
Volume = Area Height

D2
Area of digester =
4

Height = 5D
D2
V Height
4
D2
5D
4
5 D 3
V
4
4 V
D 3
5
4V 3 4 0.16
Dt 300 C 3 0.34m
5 5

h t = 300 C =5D=50.34 m =1.7m


Summary of Final answers are given in the table below:

Temperature(0C) Retention Time Diameter (m) Height (m)


(days) minimum
recommended
10 55 0.65 3.3
20 20 0.47 2.3
30 8 0.34 1.7