14380-09-34P AID: 34788 | 12/08/2017
Calculate the required digester volume based on the retention time
At T=100C ,Retention time (days) recommended 55days and Input per day is 20L( From
Given Table)
L 1m3
Vt = 20 55days 1.1m3
day 1000 L
1m3 =1000Litres
Substitute the digester dimensions have a 1:5 diameter to height ratio i.e H=5D.
Volume = Area Height
D2
Area of digester =
4
Height = 5D
D2
V Height
4
D2
5D
4
5 D 3
V
4
4 V
D 3
5
Here D =Diameter of digester
h = Height of digester
V= Volume of digester
4V 3 4 1.1
Dt 100 C 3 0.65m
5 5
h t =100 C =5D=50.65 m = 3.3m
At T=200C Retention time (days) recommended is 20days and Input per day is 20L
(From Given Table)
L 1m3
Vt =20 20days =0.4m3
day 1000 L
Volume = Area Height
D2
Area of digester =
4
Height = 5D
D2
V Height
4
D2
5D
4
5 D 3
V
4
4 V
D 3
5
4V 3 4 0.4
Dt 200 C 3 0.47m
5 5
h t = 200 C =5D=50.47 m = 2.3m
At T=300C Retention time (days) recommended 8days and Input per day is 20L (From
Given Table)
L 1m3
Vt 30 C 20
0
8days 0.16 m3
day 1000 L
Volume = Area Height
D2
Area of digester =
4
Height = 5D
D2
V Height
4
D2
5D
4
5 D 3
V
4
4 V
D 3
5
4V 3 4 0.16
Dt 300 C 3 0.34m
5 5
h t = 300 C =5D=50.34 m =1.7m
Summary of Final answers are given in the table below:
Temperature(0C) Retention Time Diameter (m) Height (m)
(days) minimum
recommended
10 55 0.65 3.3
20 20 0.47 2.3
30 8 0.34 1.7