Complete Installation Guide
Ethernet Extender
Model Number: SJ-L-DSL
Product Description Product Features
SJ-L-DSL is network signal extension device, which Long distance transmission as far as 5,000m.
consists of remote unit and local unit. It can transmit Max transmission rate reach 148M, 1,200 m can
network signal via any two-wire copper cable such as reach 15Mbps
Cat5, telephone or coaxial cable. The distance can
Easy installation, Cat5, telephone or coaxial cable
reach 5,000m and Max bandwidth can be up to
are available
148Mbps. Meanwhile, it also can transmit telephone
Communication rate adaptive, no need to adjust
signal simultaneously (adding an additional
Excellent real-time function, strong
splitter).
anti-interference
This device can be widely applied in network signal
extending system, network security system, network
information distribution system, network renovation
and expansion systems, railway, urban traffic, mining
and telecommunication, etc.
Connection Diagram
Page 1 of 9
Complete Installation Guide
Terminal and Dimension
Terminal Instructions
Page 2 of 9
Complete Installation Guide
Installation Instructions
1. Connect the local Ethernet Extender LAN port the port , then red power signal indicator
to the network equipment RJ45 output. lights , Link signal indicator lights
The LINE port uses RJ11 connector to
connect the two core cable (extension part). 5. When network transmission is smooth, the
2. Connect the low-voltage power supply (DC12V) to Ethernet Extender automatically tries to connect. The
the port then power signal indicator lights LINE signal indicator continuously flash
Link signal indicator lights about 10 times then they light all the time. The DATA
signal indicator quickly flash show network
3. Connect the other end of the two-core cable with signal transmission which is smooth.
RJ11 connector to the remote Ethernet Extender
LINE port .The LAN port is connected to the 6. The RESET button are used when
network equipments (such as network cameras) network transmission is not smooth. It only can
through network patch cord. recover the transmission channel of Ethernet
Extender.
4. Connect the low-voltage power supply (DC12V) to
Page 3 of 9
Complete Installation Guide
Transmission Rate Parameters
Total
Transmission Transmission Rate Transmission Rate
Cable Standard Transmission
Distance (Downlink Maximum) (Uplink Maximum)
Rate (Maximum)
150m 148Mbps 74Mbps 74Mbps
300m 90Mbps 54Mbps 36Mbps
600m 43Mbps 23Mbps 20Mbps
900m 30Mbps 15Mbps 15Mbps
26AWG/0.4mm2
1200m 15Mbps 9Mbps 6Mbps
3000m 2.4Mbps 1.3Mbps 1.1Mbps
5000m 0.79Mbps 0.44Mbps 0.35Mbps
6000m 0.25Mbps 0.15Mbps 0.1Mbps
Technical Parameters
Category Description
Available Voltage Range 12VDC
Power
Power Consumption <4.5W
4KV 10/700us, common mode lightning: Level
4
Transmission Channel Lightening 1KV 10/700us, differential mode lightning:
Level 1
Protection Executive Standard: IEC61000-4-5
1a contact discharge Level 4
Product Electrostatic Protection 1b air discharge Level 4
Executive Standard: IEC61000-4-2
Reliability MTBF >30000 hours
118mm108mm25mm(including the terminal
Dimensions (L W H)
length)
Product
Physical Material Aluminum
Characteristic Color Black
Net weight 0.5KG/ Pair
Working Temperature 050
Operating
Environment
Storage Temperature 085
Humidity 95%
Page 4 of 9
Complete Installation Guide
Accessory and Cable Tips
Use EIA/TIA568B standard to Use two wires connection (2, 3) of
make RJ45 terminal four wires to make RJ11 terminal
Telephone Line: CAT3 telephone Twisted Pair: CAT5 or above
cables or above
Coaxial Cable: RG 59 or above RJ11 to BNC connector for coax
cable transmission(Optional)
Power Adapter: DC12V/1A (Optional)
Page 5 of 9
Complete Installation Guide
Product Use Notes Simple Fault Cases
1) Signal transmission cable must be the copper
Panel
cable. Other material cables will cause the decrease Feature Phenomenon
Indicator
of signal transmission quality and distance. Power supply work
ON
2) Transmitting network data signal by mixing twisted smoothly.
POWER
pair, telephone line connection is forbidden. Power supply can not
OFF
work smoothly.
3) This device has no waterproof design. Please use The line has been
the product in dry environment. ON
activated
4) Please choose matching power supply The line has not been
LINE OFF
activated
specification (DC12V/1A) to supply power for devices
The line is trying to
respectively. Flashing
activate.
5) Check the local unit and remote unit carefully Correct connection of
ON
before use. Green indicator is remote unit. Red Ethernet interface.
LINK
Disconnection of Ethernet
indicator is local unit. If you install local unit and OFF
interface.
remote unit conversely, the devices can not work. Ethernet is receiving and
Flashing
6) Long-distance cable connections must be standard sending data.
DATA
connection method, such as welding or use No data transceiver of
OFF
Ethernet interface.
connectors. Tips: If devices activation fails, the devices will
7) If the devices fail, you do not disassemble or repair, automatically re-try to activate after an intervals. In
please contact us timely. this interval of time (about 1 minute), LINE indicator is
off.
Application Field Cases
Page 6 of 9
Complete Installation Guide
Railway System Application:
IP surveillance and network data transmission become more and more important in railway system. It refers to
digital information platforms, network data dispatching and IP surveillance, which need excellent transmission
solution. Ethernet Extender is very good choice.
Electric Power System Application:
With rapid development of the electric power system, the substations of human operating equipments gradually
become unattended and intelligent trend. Now Ethernet Extender is widely used in electric power system.
Page 7 of 9
Complete Installation Guide
Elevator System Application:
Ethernet Extender is widely used in elevator. We can transmit network data signals with two-wire in
accompanying cables. The only thing customers do is to install Ethernet Extender at both sides of the cables. It
is perfect for IP surveillance and analog system upgrade in elevator. Besides, network information publishing
platforms in the elevator also need the support of Ethernet Extender.
Page 8 of 9
Complete Installation Guide
Mining System Application:
IP surveillance and network data transmission in mining system are paid more and more attention. Traditional
mining cables resources are suitable for Ethernet Extender use. You can easily achieve high-speed network data
signal transmission by installing Ethernet Extender at both sides of the cables. It is very worthwhile to promote.
Page 9 of 9