PCV1030

FOR REPLACEMENT USE

Heat Pump 50 Hz
Introduction

Quicker, easier installation of


VRV III-Q for replacement use can be installed using existing refrigerant piping thanks to
its unique refrigerant control system with no special equipment or installation work
required. This enables renovation of the air conditioning system to be carried out quickly
and smoothly and minimises interference with operations and users in the building.

QQuick
uick QQuality
uality The

Simple use of existing refrigerant piping.


In the past, special equipment and work was needed to
clean pipes when using existing piping, but this is no
concept

Automatic measurement of the exact


volume necessary for refrigerant charging.
The exact volume of refrigerant required, which can be
longer required. A new function automatically deals difficult to assess for existing piping, is measured
with dirt (contamination) inside piping during refrigerant automatically. Charging from a gas cylinder with the exact
charging, eliminating the work involved in cleaning. volume necessary supports high-quality installation with
fewer problems.
Refrigerant charging completed
with just one switch.
With just a single switch for test operation, refrigerant
charging and removal of contamination (dirt inside piping)
are carried out at the same time and the exact volume
required is determined, simplifying the installation
process.

1
energy-saving air conditioning
Before replacement

Reuse of existing piping

After replacement

Replace Replace Replace


Replace

* It is possible to keep R-22 indoor units from K-series and later version. It is not possible to combine old R-22 and new R-410A indoor units in one
system due to incompatibility of communication.

Enables smooth replacement of air conditioning with less effect on operations and users in the building.

Installation process Conventional installation process


for replacement with for replacement of air conditioning

1 Refrigerant recovery and units removal 1 Refrigerant recovery and units removal

Reuse of existing refrigerant piping Quicker 2 Removal of existing piping


installation

2 Carry-in and installation of units 3 Installation of new piping and wiring

3 Airtightness test 4 Carry-in and installation of units

4 Vacuum drying 5 Airtightness test

Automatic test operation 6 Vacuum drying


5 Automatic refrigerant pipe cleaning
Automatic refrigerant charge
Quicker
installation 7 Refrigerant charging and volume measurement

Quicker and higher quality 8 Test operation


installation
* For reuse of existing refrigerant piping, it is possible to use piping or branched piping capable of handling 3.3 Pa or more. Heat insulation is
necessary for liquid piping and gas piping. 2
Benefits of system replacement

High COP Comparison of VRV III-Q and VRV K series

Approx.
Saves energy with high COP 4.27 81% Approx.
4 increase 3.66
We have reached a higher level of efficiency, 54%
thanks to advanced features such as the heat 3
increase
exchanger, the grille and the dual DC fans. 2.38 2.37
2

1
Conventional VRV K series
RSX(Y)8, 10K RQYQ8, 10P
(model from 14 years previous)
Cooling operation (8 HP) Cooling operation (10 HP)
• Cooling operating conditions: Indoor temp. of 27°CDB,
19.0 °CWB, and outdoor temp. of 35°CDB.

Design flexibility

Significantly more compact outdoor unit enables the effective


use of limited space!

Compact design enables the effective use of space taken up by existing machinery
Conventional : RQYQ16P
VRV K PLUS series: RX(Y)16K
16 HP outdoor unit
(model from 14 years previous)
16 HP outdoor unit Installation space Installation space
Approx.
2.25 m2 0.95 m2
58%
less space

750 mm
3005 mm 765 mm
1240 mm

High external static pressure 78.4 Pa Small and light, significantly reducing
Conventional VRV K series
constraints during carry-in
(model from 14 years previous)

49.0 Pa 78.4 Pa Carry-in possible


using ordinary
elevators Easy belt
suspension
External static pressure

78.4 Pa
Easier suction
hood connection
(field setting)
Can be carried on a
fork-lift without a
pallet
Easy installation on
each floor for use in
tall buildings

3
System flexibility

An increased number of connectable indoor units


in a single system

More indoor units can be connected in a single system, enabling consolidation of existing piping!
The number of connectable indoor units has been drastically increased from 30 to 64.
Conventional
VRV K PLUS series: RX(Y)24–30K : RQYQ40–48P
(model from 14 years previous)

Up to 30 indoor units Up to 64 indoor units


connectable connectable

Condensed into
a single system

Where several systems


used to be required ... Simple to deploy even in long, wide
buildings with many small rooms

Enables increased capacity

System can be upgraded using existing piping

VRV III-Q for replacement use enables the system capacity to be increased
without changing the refrigerant piping. For example, it is possible to install a
16 HP VRV III-Q using the refrigerant piping of an 10 HP R-22 system.

Before replacement
Pipe size: 28.6, 12.7
10 HP
2.5 HP x 4 units

Reuse of existing piping

After replacement
Pipe size: 28.6, 12.7

16 HP
4.0 HP x 4 units

* For reuse of existing refrigerant piping, it is possible to use piping or branched piping capable of handling 3.3 Pa or more. Heat insulation is
necessary for liquid piping and gas piping. 4
Lineup

System lineup for replacement use

Outdoor units

8, 10,12 HP 14, 16 HP 18, 20, 22, 24 HP 26, 28 HP 30, 32 HP

RQYQ8PY1
RQYQ14PY1 RQYQ18PY1 RQYQ22PY1 RQYQ26PY1 RQYQ30PY1
RQYQ10PY1
RQYQ16PY1 RQYQ20PY1 RQYQ24PY1 RQYQ28PY1 RQYQ32PY1
RQYQ12PY1

34, 36, 38, 40 HP 42, 44 HP 46, 48 HP

RQYQ34PY1 RQYQ38PY1 RQYQ42PY1 RQYQ46PY1


RQYQ36PY1 RQYQ40PY1 RQYQ44PY1 RQYQ48PY1

Outdoor unit combinations


Total capacity index of
Capacity connectable indoor units*2 *3 Maximum number of
HP Model name Combination Outdoor unit multi
1
index connection piping kit* Combination (%) connectable indoor units
50% 100% 130%
8 HP 200 RQYQ8PY1 RQYQ8PY1 – 100 200 260 13
10 HP 250 RQYQ10PY1 RQYQ10PY1 – 125 250 325 16
12 HP 300 RQYQ12PY1 RQYQ12PY1 – 150 300 390 19
14 HP 350 RQYQ14PY1 RQYQ14PY1 – 175 350 455 22
16 HP 400 RQYQ16PY1 RQYQ16PY1 – 200 400 520 26
18 HP 450 RQYQ18PY1 RQYQ8PY1 + RQYQ10PY1 225 450 585 29
20 HP 500 RQYQ20PY1 RQYQ8PY1 + RQYQ12PY1 250 500 650 32
22 HP 550 RQYQ22PY1 RQYQ10PY1 + RQYQ12PY1 275 550 715 35
24 HP 600 RQYQ24PY1 RQYQ12PY1 + RQYQ12PY1 300 600 780 39
BHFP22P100
26 HP 650 RQYQ26PY1 RQYQ10PY1 + RQYQ16PY1 325 650 845 42
28 HP 700 RQYQ28PY1 RQYQ12PY1 + RQYQ16PY1 350 700 910 45
30 HP 750 RQYQ30PY1 RQYQ14PY1 + RQYQ16PY1 375 750 975 48
32 HP 800 RQYQ32PY1 RQYQ16PY1 + RQYQ16PY1 400 800 1,040 52
34 HP 850 RQYQ34PY1 RQYQ10PY1 + RQYQ10PY1 + RQYQ14PY1 425 850 1,105 55
36 HP 900 RQYQ36PY1 RQYQ10PY1 + RQYQ10PY1 + RQYQ16PY1 450 900 1,170 58
38 HP 950 RQYQ38PY1 RQYQ10PY1 + RQYQ12PY1 + RQYQ16PY1 475 950 1,235 61
40 HP 1,000 RQYQ40PY1 RQYQ12PY1 + RQYQ12PY1 + RQYQ16PY1 500 1,000 1,300
42 HP 1,050 RQYQ42PY1 RQYQ10PY1 + RQYQ16PY1 + RQYQ16PY1 BHFP22P151 525 1,050 1,365
44 HP 1,100 RQYQ44PY1 RQYQ12PY1 + RQYQ16PY1 + RQYQ16PY1 550 1,100 1,430 64
46 HP 1,150 RQYQ46PY1 RQYQ14PY1 + RQYQ16PY1 + RQYQ16PY1 575 1,150 1,495
48 HP 1,200 RQYQ48PY1 RQYQ16PY1 + RQYQ16PY1 + RQYQ16PY1 600 1,200 1,560
*1 For multiple connections of 18 HP systems and above, the outdoor unit multi connection piping kit (separately sold) is required.
*2 Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor units.
*3 When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30%
of the capacity index of the outdoor units.

5
System lineup for replacement use

Indoor units

Ceiling Mounted Cassette Ceiling Mounted Cassette Ceiling Mounted Cassette


(Round Flow) (Compact Multi Flow) (Double Flow)

FXFQ25/32/40/50/63/80/100/125PVE FXZQ20/25/32/40/50MVE FXCQ20/25/32/40/50/63/80/125MVE

Ceiling Mounted Cassette Corner Slim Ceiling Mounted Duct


700 mm width type 900/1,100 mm width type
–with drain pump –with drain pump
–without drain pump –without drain pump

FXKQ25/32/40/63MAVE FXDQ20/25/32PBVE(T) FXDQ40/50/63NBVE(T)

Ceiling Mounted Duct Ceiling Suspended Wall Mounted

FXMQ20/25/32/40/50/
63/80/100/125/140PVE

FXHQ32/63/100MAVE FXAQ20/25/32/40/50/63MAVE
FXMQ200/250MAVE

Floor Standing Concealed Floor Standing Connection unit series

Ceiling Suspended Cassette

Connection unit
FXLQ20/25/32/40/50/63MAVE FXNQ20/25/32/40/50/63MAVE FXUQ71/100/125MAV1 BEVQ71/100/125/MAVE

Air treatment equipment

Outdoor-Air Processing Unit HRV with DX-Coil and Humidifier Heat Reclaim Ventilation

VAM150/250/350/500/650/
FXMQ125/200/250MFV1 VKM50/80/100GA(M)V1 800/1000/1500/2000GJVE

* It is possible to keep R-22 indoor units from K-series and later version. It is not possible to combine old R-22 and new R-410A indoor units in one
system due to incompatibility of communication.

6
Guidelines for reuse of existing refrigerant piping
Piping limits for reuse of existing piping
Single use Multiple use

a k
f g h
q
b c d e i
First indoor branch
First
r indoor branch

p a f
s First outdoor branch b
*The rest of indoor units are
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a . the same as for single use.

Actual Equivalent
piping length Example piping length
Refrigerant piping length 150 m a+f+g+h+i 175 m
Maximum Total piping length 300 m a+b+c+d+e+f+g+h+i —
allowable
piping length Between the first indoor branch and the farthest indoor unit 40 m f+g+h+i —

Between the outdoor branch and the last outdoor unit 10 m k+p 13 m

Level Difference Example


Between the outdoor units (Multiple use) 5m q
Maximum
allowable Between the indoor units 15 m s
level difference If the outdoor unit is above. 50 m r
Between the outdoor units
and the indoor units If the outdoor unit is below. 40 m r

Reusability of existing piping for VRVIII-Q


Piping size
Type of piping Capacity Liquid Gas
6.4 9.5 12.7 15.9 19.1 22.2 12.7 15.9 19.1 22.2 25.4 28.6 34.9 41.3 54.1
8 HP X X X X X X X X X X
10 HP X X X X X X X X X
12 HP X X X X X X X X X X X X
14 HP X X X X X X X X X X X
16 HP X X X X X X X X X X X
18 HP X X X X X X X X X X X
20 HP X X X X X X X X X X X
22 HP X X X X X X X X X X X
24 HP X X X X X X X X X X X

Main piping 26 HP X X X X X X X X X X X
28 HP X X X X X X X X X X X
30 HP X X X X X X X X X X X
32 HP X X X X X X X X X X X
34 HP X X X X X X X X X X X
36 HP X X X X X X X X X X X
38 HP X X X X X X X X X X X
40 HP X X X X X X X X X X X
42 HP X X X X X X X X X X X
44 HP X X X X X X X X X X X
46 HP X X X X X X X X X X X
48 HP X X X X X X X X X X X
< 100 X X X X X X X X X X X
100 ≤ X < 150 X X X X X X X X X X X
150 ≤ X < 160 X X X X X X X X X X
160 ≤ X < 200 X X X X X X X X X X
From
200 ≤ X < 290 X X X X X X X X X
REFNET
<
to REFNET *1 290 ≤ X 330
X X X X X X X X X X
330 ≤ X < 420 X X X X X X X X X X X
420 ≤ X < 480 X X X X X X X X X X
480 ≤ X < 640 X X X X X X X X X X
640 ≤ X < 900 X X X X X X X X X
900 ≤ X < 920 X X X X X X X X X
920 ≤ X X X X X X X X X X X
20–40 class X X X X X X X X X X X
50 class X X X X X X X X X X X
From 63 class X X X X X X X X X X X
REFNET 80 class X X X X X X X X X X X
*2
to indoor unit 100–125 class X X X X X X X X X
140 class X X X X X X X X X
200 class X X X X X X X X X
250 class X X X X X X X X X X

: Piping size of conventional R-22 model : Possible


: Piping size of conventional R-410A model : Standard piping size of VRV III-Q. However, when equivalent piping length between outdoor unit and indoor unit
: Standard piping size of VRVIII-Q is 90 m or more, size of main piping must be increased.
X : Not possible

*1 Piping between REFNETs depends on total capacity index of indoor units connected below each REFNET. It cannot exceed piping size of upstream side.
7 *2 Piping from REFNET to indoor unit depends on the capacity of the connected indoor unit. It cannot exceed piping size of upstream side.
Specifications

Outdoor units

Heat Pump
MODEL RQYQ8PY1 RQYQ10PY1 RQYQ12PY1 RQYQ14PY1 RQYQ16PY1
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz
kcal/h(*1) 19,400 24,300 29,000 34,600 39,000
Btu/h(*1) 76,800 96,200 115,000 137,000 155,000
Cooling capacity (*1)(*2)
(*1) 22.5 28.2 33.7 40.2 45.3
kW
(*2) 22.4 28.0 33.5 40.0 45.0
kcal/h 21,500 27,100 32,300 38,700 43,000
Heating capacity Btu/h 85,300 107,000 128,000 154,000 171,000
kW 25.0 31.5 37.5 45.0 50.0
Cooling (*2) 5.24 7.64 10.1 11.6 13.6
Power consumption kW
Heating 6.42 8.59 10.2 12.2 13.6
Capacity control % 20-100 14-100 14-100 10-100 10-100
Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor
Motor output kW 4.5X1 (1.4+4.5)X1 (3.3+4.5)X1 (1.6+4.5+4.5)X1 (2.7+4.5+4.5)X1
Airflow rate m3/min 180 185 200 233 233
Dimensions (HXWXD) mm 1,680X930X765 1,680X1,240X765
Machine weight kg 230 284 284 381 381
Sound level dB(A) 57 58 60 60 60
Operation Cooling °CDB –5 to 43
range Heating °CWB –20 to 15.5
Type R-410A
Refrigerant
Charge kg 10.8 11.7 11.7 11.7 11.7
Piping Liquid 9.5 (Brazing) 9.5 (Brazing) 12.7 (Brazing) 12.7 (Brazing) 12.7 (Brazing)
mm
connections Gas 19.1 (Brazing) 22.2 (Brazing) 28.6 (Brazing) 28.6 (Brazing) 28.6 (Brazing)

RQYQ18PY1 RQYQ20PY1 RQYQ22PY1 RQYQ24PY1 RQYQ26PY1 RQYQ28PY1 RQYQ30PY1 RQYQ32PY1


MODEL Combination RQYQ8PY1 RQYQ8PY1 RQYQ10PY1 RQYQ12PY1 RQYQ10PY1 RQYQ12PY1 RQYQ14PY1 RQYQ16PY1
units RQYQ10PY1 RQYQ12PY1 RQYQ12PY1 RQYQ12PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz
kcal/h (*1) 43,600 48,300 53,200 58,000 63,300 67,900 73,500 78,000
Btu/h(*1) 173,000 192,000 211,000 230,000 251,000 270,000 292,000 310,000
Cooling capacity (*1)(*2)
(*1) 50.7 56.2 61.9 67.4 73.5 79.0 85.5 90.6
kW
(*2) 50.4 55.9 61.5 67.0 73.0 78.5 85.0 90.0
kcal/h 48,600 53,800 59,300 64,500 70,100 75,300 81,700 86,000
Heating capacity Btu/h 193,000 213,000 235,000 256,000 278,000 299,000 324,000 341,000
kW 56.5 62.5 69.0 75.0 81.5 87.5 95.0 100
Cooling (*2) 12.9 15.4 17.8 20.2 21.3 23.7 25.2 27.2
Power consumption kW
Heating 15.1 16.7 18.8 20.4 22.2 23.8 25.8 27.2
Capacity control % 9-100 8-100 7-100 6-100 6-100 5-100 5-100 5-100
Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor (4.5X1)+ (4.5X1)+ ((1.4+4.5)X1)+ ((3.3+4.5)X1)+ ((1.4+4.5)X1)+ ((3.3+4.5)X1)+ ((1.6+4.5+4.5)X1)+ ((2.7+4.5+4.5)X1)+
Motor output kW
((1.4+4.5)X1) ((3.3+4.5)X1) ((3.3+4.5)X1) ((3.3+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1)
Airflow rate m3/min 180+185 180+200 185+200 200+200 185+233 200+233 233+233 233+233
Dimensions (HXWXD) mm (1,680X930X765)+(1,680X930X765) (1,680X930X765)+(1,680X1,240X765) (1,680X1,240X765)+(1,680X1,240X765)
Machine weight kg 230+284 230+284 284+284 284+284 284+381 284+381 381+381 381+381
Sound level dB(A) 61 62 63 63 63 63 63 63
Operation Cooling °CDB –5 to 43
range Heating °CWB –20 to 15.5
Type R-410A
Refrigerant
Charge kg 10.8+11.7 10.8+11.7 11.7+11.7 11.7+11.7 11.7+11.7 11.7+11.7 11.7+11.7 11.7+11.7
Piping Liquid 15.9 (Brazing) 15.9 (Brazing) 15.9 (Brazing) 15.9 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing)
mm
connections Gas 28.6 (Brazing) 28.6 (Brazing) 28.6 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing)
Note: Specifications are based on the following conditions; • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the
•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. unit at a height of 1.5 m.
(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB. During actual operation, these values are normally somewhat higher as a
• Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. result of ambient conditions.
•Equivalent piping length: 7.5 m
•Level difference: 0 m

8
Specifications

Outdoor units

Heat Pump
RQYQ34PY1 RQYQ36PY1 RQYQ38PY1 RQYQ40PY1 RQYQ42PY1 RQYQ44PY1 RQYQ46PY1 RQYQ48PY1
MODEL RQYQ10PY1 RQYQ10PY1 RQYQ10PY1 RQYQ12PY1 RQYQ10PY1 RQYQ12PY1 RQYQ14PY1 RQYQ16PY1
Combination RQYQ10PY1 RQYQ10PY1 RQYQ12PY1 RQYQ12PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
units RQYQ14PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz
kcal/h (*1) 83,200 87,700 92,900 97,200 102,000 108,000 113,000 117,000
Btu/h(*1) 329,000 348,000 368,000 386,000 406,000 427,000 447,000 464,000
Cooling capacity (*1)(*2)
(*1) 96.6 102 108 113 119 125 131 136
kW
(*2) 96.0 101 107 112 118 124 130 135
kcal/h 92,700 97,200 102,000 108,000 114,000 119,000 125,000 129,000
Heating capacity Btu/h 368,000 386,000 406,000 427,000 450,000 471,000 495,000 521,000
kW 108 113 119 125 132 138 145 150
Cooling (*2) 26.9 28.9 31.4 33.8 34.9 35.3 38.8 40.8
Power consumption kW
Heating 29.4 30.8 32.4 34.0 35.8 36.0 39.4 40.8
Capacity control % 5-100 4-100 4-100 4-100 4-100 4-100 3-100 3-100
Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor ((1.4+4.5)X1)+ ((1.4+4.5)X1)+ ((1.4+4.5)X1)+ ((3.3+4.5)X1)+ ((1.4+4.5)X1)+ ((3.3+4.5)X1)+ ((1.6+4.5+4.5)X1)+ ((2.7+4.5+4.5)X1)+
Motor output kW ((1.4+4.5)X1)+ ((1.4+4.5)X1)+ ((3.3+4.5)X1)+ ((3.3+4.5)X1)+ ((2.7+4.5+4.5)X1)+ ((2.7+4.5+4.5)X1)+ ((2.7+4.5+4.5)X1)+ ((2.7+4.5+4.5)X1)+
((1.6+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1) ((2.7+4.5+4.5)X1)
Airflow rate m3/min 185+185+233 185+185+233 185+200+233 200+200+233 185+233+233 200+233+233 233+233+233 233+233+233

(1,680X930X765)+(1,680X930X765)+(1,680X1,240X765) (1,680X930X765)+(1,680X1,240X765) (1,680X1,240X765)+(1,680X1,240X765)


Dimensions (HXWXD) mm +(1,680X1,240X765) +(1,680X1,240X765)
Machine weight kg 284+284+381 284+284+381 284+284+381 284+284+381 284+381+381 284+381+381 381+381+381 381+381+381
Sound level dB(A) 64 64 65 65 65 65 65 65
Operation Cooling °CDB –5 to 43
range Heating °CWB –20 to 15.5
Type R-410A
Refrigerant
Charge kg 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7
Piping Liquid 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing)
mm
connections Gas 34.9 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing)
Note: Specifications are based on the following conditions; •Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the
•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. unit at a height of 1.5 m.
(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB. During actual operation, these values are normally somewhat higher as a
• Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. result of ambient conditions.
•Equivalent piping length: 7.5 m
•Level difference: 0 m

9
Option List

Outdoor units

Type RQYQ8PY1 RQYQ18PY1


RQYQ14PY1
No. RQYQ10PY1 RQYQ20PY1
RQYQ16PY1
Item RQYQ12PY1 RQYQ22PY1
1 Cool/Heat Selector KRC19–26A
1-1 Fixing box KJB111A
KHRP26M22H (Max. 4 branch) KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)
2 Distributive REFNET header KHRP26M33H (Max. 8 branch) KHRP26M72H (Max. 8 branch)
piping
REFNET joint KHRP26A22T, KHRP26A33T KHRP26A22T, KHRP26A33T, KHRP26A72T
3 Outdoor unit multi connection piping kit — — BHFP22P100
4 Central drain pan kit KWC26C280 KWC26C450 KWC26C280X2
5 Digital pressure gauge kit BHGP26A1 BHGP26A1X2

Type RQYQ34PY1
RQYQ26PY1 RQYQ30PY1 RQYQ36PY1 RQYQ42PY1 RQYQ46PY1
No. RQYQ24PY1
RQYQ28PY1 RQYQ32PY1 RQYQ38PY1 RQYQ44PY1 RQYQ48PY1
Item RQYQ40PY1

1 Cool/Heat Selector KRC19–26A


1-1 Fixing box KJB111A

KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)


REFNET header
Distributive KHRP26M72H (Max. 8 branch), KHRP26M73H (Max. 8 branch)
2
piping
REFNET joint KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

3 Pipe size reducer KHRP26M73TP, KHRP26M73HP


4 Outdoor unit multi connection piping kit BHFP22P100 BHFP22P151
KWC26C280 KWC26C280X2 KWC26C280
5 Central drain pan kit KWC26C280X2 KWC26C450X2 KWC26C450X3
KWC26C450 KWC26C450 KWC26C450X2
6 Digital pressure gauge kit BHGP26A1X2 BHGP26A1X3

Control Systems

Building Management System


No. Item Model No. Function
1 Basic Hardware intelligent Touch Controller DCS601C51 •Air-Conditioning management system that can be controlled by a compact all-in-one unit.
1-1 intelligent Touch Hardware DIII-NET plus adaptor DCS601A52 •Additional 64 groups (10 outdoor units) is possible.
1-2 Controller Option PPD DCS002C51 •PPD: Power Proportional Distribution function
Software
1-1
1-3 Web DCS004A51 •Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.
1-4 Electrical box with earth terminal (4 blocks) KJB411AA •Wall embedded switch box.
128 units DAM602B52
256 units DAM602B51
Number of
2 Basic Hardware units to be 512 units DAM602B51x2 •Air conditioner management system that can be controlled by personal computers.
connected
768 units DAM602B51x3

intelligent Manager III 1024 units DAM602B51x4

2-1 PPD DAM002A51 •Power Proportional Distribution function

2-2 Option Software Web DAM004A51 •Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.

2-3 ECONO DAM003A51 •ECONO (Energy saving functions.)

2-4 Optional DIII Ai unit DAM101A51 •External temperature sensor for intelligent Manager III.

2-5 Di unit DEC101A51 •8 pairs based on a pair of On/Off input and abnormality input.

2-6 Dio unit DEC102A51 •4 pairs based on a pair of On/Off input and abnormality input.
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
Communication line

3 *1 Interface for use in BACnet ®


DMS502B51 conditioning systems through BACnet communication.
®

•Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable
3-1 Optional DIII board DAM411B51 independently.
•Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable
3-2 Optional Di board DAM412B51 independently.
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
4 *2 Interface for use in LONWORKS ®
DMS504B51 conditioning systems through LONWORKS communication.
®

5 Parallel interface DPF201A51 •Enables ON/OFF command, operation and display of malfunction; can be used in combination with up to
Contact/analogue

Basic unit 4 units.


6 Temperature DPF201A52 •Enables temperature measurement output for 4 groups; 0-5VDC.
signal

measurement units
7 Temperature DPF201A53 •Enables temperature setting input for 16 groups; 0-5VDC.
setting units
8 Unification adaptor for DCS302A52 •Interface between the central monitoring board and central control units.
computerised control
Notes: *1. BACnet ® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*2. LONWORKS® is a registered trade mark of Echelon Corporation.
*3. Installation box for adaptor must be obtained locally.

Air Conditioning Network Service System (Optional Maintenance Service) is also available.
10
Warning Daikin Industries , Ltd.’s products are manufactured for export to numerous countries throughout the
world. Dai kin Industries, Ltd. does not have control over which products are exported to and used in a
particular country. P rior to purchase , please there fore confirm with your local authorised importer,
distributor and/ or retailer whether this product conforms to the applicable standards , and is suitable for
use , in the region where the product will be used. T his st atement does not purport to exclude, restrict
or modify the applica tion of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yoursel f.
Improper installa tion can result in water or refrigeran t leakage , elec trical shock , fire or explosion .
Use only those parts and access ories supplied or specified by Dai kin. Ask a qualified installer or
contrac tor to install those parts and acce ssories . Use of unauthorised parts and accessories or
improper installa tion of parts and accessorie s can resul t in water or refrigeran t leakage , elec trical
shock, fire or explosion.
Read the User 's Manual care fully before using this product. T he User's Manual provides important
safety instructions and warnings. B e sure to follow these instructions and warnings .
If y ou have any enquiries , please contac t your local importer, distributor and/ or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gase s, such as acid gas or alkaline gas , are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided . If you need to install
the outdoor unit close to the sea shore , contact your local distributor.

Organization:
DAIKIN INDUSTRIES, LTD. Organization:
AIR CONDITIONING MANUFACTURING DIVISION DAIKIN INDUSTRIES
(THAILAND) LTD. All of the Daikin Group’s business
Scope of Registration: facilities and subsidiaries in Japan
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF Scope of Registration:
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, THE DESIGN/DEVELOPMENT international standard for
REFRIGERATING EQUIPMENT, COMMERCIAL HEATING AND MANUFACTURE OF AIR environment management.
EQUIPMENT, RESIDENTIAL AIR CONDITIONING CONDITIONERS AND THE
EQUIPMENT, HEAT RECLAIM VENTILATION, AIR COMPONENTS INCLUDING
JMI-0107 CLEANING EQUIPMENT, MARINE TYPE CONTAINER JQA-1452 COMPRESSORS USED FOR THEM
REFRIGERATION UNITS, COMPRESSORS AND VALVES.

Dealer
HEAD OFFICE
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
CON
 G TY COÅ PHANÀ VIETÄ KIM
VAN
Ê PHON
Ø G CHÍNH
TRUNG TÂM Tanàg 14-15, toaø nhaø Nam A,Ù 201-203 Cacùh Manïg Thanùg 8, P.4, Q.3, TP.HCM
Tel: (08) 62 504 888 Fax: (08) 62 504 999
DICH VU KHÁCH HÀNG
CHI NHAN
Ù H HAØ NOIÄ
Tanàg 12, toaø nhaø Ocean Park Tower, 1 Ñaoø Duy Anh, Quanä Ñonág Ña, Haø Noiä
Tel: (04) 35 657 677 Fax: (04) 35 657 688
Miễn phí cöôùc cuoäc goïi CHI NHAN
Ù H ÑAØ NAN
Ü G
Tanàg 12, Loâ A2.1, Ñöônøg 30/4, P. Hoaø Cöônøg Bacé, Q. Haiû Chauâ, TP. Ñaø Nanüg
Tel: (0511) 362 4250 Fax: (0511) 362 4251
www.daikin.com.vn