0% found this document useful (0 votes)
314 views6 pages

Logiq 9: Truscan Imaging Technology

The LOGIQ 9 is GE's top ultrasound system for abdominal, vascular, obstetric, and other applications. It features TruScan imaging software for enhanced image processing and TruAccess raw data technology. The system has a touch screen, adjustable keyboard, and multiple probe ports. Peripheral options include printers, video outputs, and DICOM connectivity for image sharing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
314 views6 pages

Logiq 9: Truscan Imaging Technology

The LOGIQ 9 is GE's top ultrasound system for abdominal, vascular, obstetric, and other applications. It features TruScan imaging software for enhanced image processing and TruAccess raw data technology. The system has a touch screen, adjustable keyboard, and multiple probe ports. Peripheral options include printers, video outputs, and DICOM connectivity for image sharing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

GE Medical Systems – Americas: 888-202-5528

P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A.


GE Ultrasound - Europe: +49-212-28020
P.O. Box 1105 60 D-42665 Solingen
GE Ultrasound – Asia +86- 21-52080200
Shanghai Maxdo Center, No. 8 Xing Yi Road,
Shanghai, China 200336
http://www.gemedicalsystems.com

LOGIQ 9
20-November-2002
TruScan Imaging Technology

• Integrated locking mechanism that


Product Description provides rolling lock and caster
The LOGIQ 9 is our leadership swivel lock
• Integrated cable management
imaging system designed for • Front and rear handles
abdominal, vascular, obstetrics, • Easily removable air filter
gynecology, neonatal, urology,
transcranial, and small parts
applications. User Interface
System Architecture Operator Keyboard
• Floating keyboard adjustable in three
TruScan Architecture – our dimensions:
exclusive, software-intensive, • Height: adjustable 76.2 – 96.5 cm
ultrasound imaging platform gives you (30 - 38 in)
unsurpassed computational power, • Rotation: adjustable +/-75o from
image-manipulation capability, center
workflow flexibility and product • Extension: 31.8 cm (12.5 in) from
upgrade-ability. console
• Full-sized, backlit alphanumeric
TruAccess is the new, GE-exclusive, keyboard
raw-data processing technology that • Ergonomic hard key layout
will change the future of ultrasound • Interactive back-lighting
imaging. By accessing raw data, • Integrated recording keys for remote
TruAccess achieves excellent image control of up to 4 peripheral or
quality today and ensures unsurpassed DICOM devices
• Height - Min: 140.3 cm (55.25 in) - • Integrated gel warmer
image management tomorrow. Max: 160.7 cm (63.25 in)
CodeScan, Coded Technology, • Width: 64 cm (25.2 in) Touch Screen
improves image quality and penetration • Depth: 89.9 cm (35.4 in) • 10.4 in High Resolution color LCD
• Weight (no peripherals): 196.8 kg
while Multi-Level Codes provides (434 lb)
screen
greater bandwidth control. • Interactive dynamic software menu
Electrical Power • Brightness adjustment
SmartScan improves image • User-configurable layout
• Voltage:100-120 Vac or 220-240 Vac
acquisition and patient throughput • Frequency: 50/60 Hz
while increasing diagnostic confidence Monitor
• Power: Max. 1.2 KVA with on-board
and exam consistency. peripherals • 17′′ High-Resolution non-interlaced
• Maximum Thermal Output: 4095 scan flat CRT
ComfortScan, our most advanced BTU/hr. • Center of monitor height adjustable
ergonomic design ever, helps maximize (with keyboard): 125.7 – 146.1 cm
productivity and simplify every exam Console Design (49.5 – 57.5 in)
you perform. • 4 Active Probe Ports • Tilt/Rotate Adjustable Monitor
• Integrated HDD (40 GB) • Tilt Angle: Down 10°, Up 10°
• Integrated CD-RW drive • Rotate Angle: 90° right, 90° left
General Specifications •

Integrated MO drive • Wide Image area
On-board storage for peripherals • Integrated high-fidelity speakers
Dimensions and Weight • Wheels • Digital brightness & contrast
(Dimensions given with floating • Wheel diameter: adjustment.
keyboard stowed for transport) Front: 175 mm
Rear: 175 mm

LOGIQ 9 Product Data Sheet 2350082GSP Rev. 3 Page 1 of 6


System Options • Hospital Name: 23 Characters.
System Overview • B-Flow • Date: 2 Types selectable
Applications • LOGIQView MM/DD/YY,
• Abdominal • Coded Contrast Imaging DD/MM/YY
• Obstetrical • Advanced 3D • Time: 2 types selectable
• Gynecological • Tru3D – sensor-based and 24 hours, 12 hours
• Breast quantitative • Gestational Age from
• Small parts • DICOM 3.0 connectivity LMP/EDD/GA/BBT
• Vascular / Intraoperative/ Peripheral • Foot Switch, with programmable • Probe Name
• Transcranial functionality • Gray Map names
• Pediatric and Neonatal • Probe Orientation
• Musculoskeletal • Console Protective Cover
• Depth Scale Marker
• Urological Peripheral Options • Lateral Scale Marker
Operating Modes • Integrated mounting kits provided • Focal Zone Markers
• B-Mode for: • Image Depth
• M-Mode • Analog B&W thermal printer • Zoom Depth
• Color Flow Mode (CFM) • Analog A6 or A5 color thermal • B-Mode
• Power Doppler Imaging (PDI) with printer • Gain
topographic and directional maps • Digital B&W thermal printer • Dynamic Range
• PW Doppler with high PRF • Digital A6 color thermal printer • Imaging Frequency
• B-Flow Mode • Analog S-VHS VCR • Edge Enhance
• M-Color Flow Mode • External Color PC desktop printer & • Frame Averaging
connection kit • Gray Map
Scanning Methods • External video & audio connections • M-Mode
• Electronic Sector provided for other devices such as • Gain
• Electronic Convex Multi-format cameras, laser cameras, • Dynamic Range
• Electronic Linear and other peripherals • Time Scale
• Doppler Mode
Transducer Types Display Modes • Gain
• Sector Phased Array • Simultaneous Capability
• • Angle
Convex Array • B/PW • Sample Volume Depth and Width
• Microconvex Array • B/CFM or PDI
• Linear Array • Wall Filter
• B/M • Velocity and/or Frequency Scale
• Matrix Array
• Real-time Triplex Mode • Spectrum Inversion
System Standard Features (B + CFM or PDI/PW) • Time Scale
• State-of-the-art user interface with • B-Flow + PW • PRF
high resolution 10.4 inch LCD touch • Selectable alternating Modes • HPRF
panel • B/PW • Doppler Frequency
• Automatic Tissue Optimization • B + CFM (PDI)/PW • Color Flow Doppler Mode
• Fine Angle Steer • B-Flow/PW • Line Density
• Coded Excitation • Multi-image (split/quad screen) • Frame Averaging
• Coded Harmonic Imaging • Live and/or frozen • Packet Size
• Virtual Convex • B + B/CFM or PDI • Color Scale: 3 types
• Patient information database • PW/M Power, Directional PDI, and
• Image Archive on CD, MOD, and • Independent Cine playback Symmetrical Velocity Imaging
hard drive • Zoom Read/Write/Pan • Color Velocity Range and Baseline
• Integrated MO drive (supports 128, • Colorized Image • Color Threshold Marker
230, 540, 640 MB or 1.3 GB disks) • Colorized B • Color Gain
• Easy 3D (Freehand acquisition with • Colorized M • PDI
basic features) with 3D Movie • Colorized PW • Spectrum Inversion
• Raw Data Analysis • Time line display • Doppler Frequency
• Independent Dual B/PW Display • TGC Curve
• Real-time automatic Doppler calcs
• Display Formats • Acoustic Frame Rate
• OB Calcs
• Fetal Trending
Top/ Bottom selectable format (Size: • Cine Frame Number
1/2:1/2; 1/3:2/3; 2/3:1/3) • VCR Counter
• Multigestational Calcs
Side/Side selectable format • VCR Status
• Hip Dysplasia Calcs (1/2:1/2; 1/3:2/3; 0:1) • VCR Playback Counter
• Gynecological Calcs • Virtual Convex • Body Pattern: Up to 90 human types
• Vascular Calcs plus 13 animal types
• Urological Calcs Display Annotation • Application Name
• Renal Calcs • Patient Name: First, Last, & Middle • Measurement Results
• Insite capability name each store 27 characters. Up to • Operator Message
• iLinq capability 27 total characters displayed. • Displayed Acoustic Output
• On-board electronic documentation • Patient ID: 31 Characters. Up to 27 • TIS: Thermal Index Soft Tissue
total characters displayed. • TIC: Thermal Index Cranial
• Age, Sex and Birth Date (optional) (Bone)
• TIB: Thermal Index Bone

LOGIQ 9 Product Data Sheet 2350082GSP Rev. 3 Page 2 of 6


• MI: Mechanical Index Post-Processing • Scrolling timeline memory
• % of Power output • Max Read Zoom to 8x
• Biopsy Guide Line and Zone • Base Line Shift Image Storage
• Sweep Speed • On-board database of patient
• B/M-Mode information from past exams
• Storage Format: DICOM
System Parameters • Gray Map
• Image Storage Size:
• Colorized B and M
System Setup • Post Gain − Gray Image: ~300K to ~1.3 MB
• Pre-programmable Categories • Compression − Color Image: ~900K to 1.9 MB
• User Programmable Preset Capability • Anatomical M Mode • Multiframe
• Factory Default Preset Data • PW Mode • Display Format: Full size, 4x3, and
• Languages: English, French, German, • Gray Map "thumbnails"
Spanish, Italian, Portuguese, Russian, • Post Gain • Live image and stored image side-by-
Greek, Swedish, Danish, Dutch, • Compression side display
• Rejection • MO Disk Storage: 128, 230, 540, 640
Finnish, Norwegian
• Colorized D
• OB Report Format: 5 Types, Tokyo • Color Tag
MB or 1.3 GB
Univ., Osaka Univ., USA, Europe, • CD-RW storage
• Display Format
and ASUM • Conversion to JPEG and AVI file
• Color Flow
• EFBW: 8 types, Tokyo • Color Map
formats
University, Osaka University, USA • CFM Velocity Tag • Hard Drive Image Storage: 18.1 GB
and Europe (Shephard, Merz, • CFM Display Threshold
Hadlock/Shephard, Williams, Connectivity
• Angle Correct (PW mode) • Ethernet network connection
Brenner) • Quick Angle Correct (PW mode)
• • RS-232 serial data output
Up to 90 Programmable Annotations • Auto Angle Correct (PW mode)
• • DICOM support (option)
Body Patterns • Spectral Invert for Color and
• Customized Comment Home Position • Verify
Doppler
• Print
Pre-Processing • Store
• Write Zoom up to 4x Image Processing and • Modality Worklist
• B/M-Mode
• Gain
Presentation • Storage Commitment
• Modality Performed Procedure
• TGC • Digital Beamformer Step (MPPS)
• Dynamic Range • Media Exchange
• 1024 system processing channel
• Acoustic Output • Off network / mobile storage queue
technology
• Transmission Focus Position
• Displayed Imaging Depth: 0 – 36 cm Raw Data Processing
• Transmission Focus Number
• Minimum Depth of Field: 0 – 2 cm • Complete image flexibility allows
• Edge Enhancement
(Zoom) (probe dependent)
• Smoothing Control stored image optimization and
• Line Density Control • Maximum Depth of Field: 0 – 36 cm measurements. :
• Sweep Speed for M-Mode (probe dependent) • Overall B-Mode gain, dynamic
• PW-Mode • Transmission Focus range and gray scale maps
• Gain • 1- 8 Focus Points selectable (probe • Overall Doppler gain, baseline
• Dynamic Range and application dependent)
shift, sweep speed and inverted
• Acoustic Output • Focal Zone position, up to 12 steps
• Continuous Dynamic Receive Focus / spectral waveform.
• Transmission Frequency • Tru3D reconstruction from a stored
• PRF Continuous Dynamic Receive
Aperture CINE loop
• Wall Filter • Anatomical M-Mode
• Spectral Averaging • 256 shades of gray
• Up to 145 dB Dynamic • All Post-Processing capabilities
• Sample Volume Gate
Length Range/Displayed is 102 dB
Depth • Adjustable Field of View (FOV)
• Velocity Scale • Image Reverse: Right/ Left Scanning Parameters
• Color Flow Mode • Image Rotation: 4 steps,
• CFM Gain Rotation: 0°, 180° Digital B-Mode
• CFM Velocity Range • B Acoustic Power: 25 – 100 %
CINE Memory/Image Memory • B Gain: 120 dB range, 1 dB steps,
• Acoustic Output
• CINE Memory: 128 MB (includes slide pots)
• Wall Echo Filter
• Dual Image CINE Display • B Displayed Dynamic Range: 36 –
• Packet Size
• Frame Rate Control • CINE Gauge and CINE image 102 dB, 3-6 dB steps
• CFM Spatial Filter number display • B Frame Averaging: 7 steps
• CFM Frame Averaging • CINE Review Loop • B Gray Scale Map: 18 types
• CFM Line Resolution • CINE Review Speed: 9 types • B Edge Enhancement: 6 steps
• Frequency / Velocity Base Line (1/1, ½, 1/3, ¼, 1/5, 1/6, 1/7, 1/8, 1/9) • Frequency Selection
Shift • Selectable CINE Sequence for • Line Density: up to 5 steps
• CFM ACE-Filter CINE Review • Scanning Size (FOV or Angle
• Measurements/ Calculations & (Depending on the probe, see probe
Annotations on CINE Playback specifications)

LOGIQ 9 Product Data Sheet 2350082GSP Rev. 3 Page 3 of 6


• B Colorization: 4 color settings • CFM Window Size (same as B- Coded Excitation
• Image Softener: 4 steps Mode): • Available on the following probes:
• Reject: 6 steps • Convex 5° - 120° • M7C
• Suppression: 6 steps • Sector 10° - 90° • E8C
• Linear 5 mm - 46 mm • 10L
Digital M-Mode (Depending on the probe) • 10S
• M Acoustic Power: 25 – 100 % • Maximum Steerable Angle • 8C
• M Gain: 120 dB range, 1 dB steps, (Slant Scan): +/- 20 °
includes slide pots • CFM Spectrum Inversion Coded Harmonic Imaging
• M Displayed Dynamic Range: 36 – • Available on all probes
102 dB, 3-6 dB steps • CFM Baseline Shift: 11 steps
• M Gray Scale Map: 18 types • Pre-settable and independently
Coded Contrast Imaging (option
• M Edge Enhancement: 6 step- adjustable B-Mode Gain in B/CFM-
• M Sweep Speed: 8 types Mode available only outside the United
• M Colorization: 4 colors • CFM Frame Average: 7 steps States.)
• CFM/M-Mode capability • CFM Threshold: 0 - 100% • Available on 3.5C, 4S, M7C, 7L,
• Realtime Triplex Mode: 10L, & M12L probes
Anatomical M-Mode B + CFM/PW in any depth, at any • Contrast Timer
• M-mode cursor adjustable at any PRF • Timed Updates: 0.5 – 10 seconds
plane • 3 fundamental frequencies on 3.5C,
• Can be activated from a CINE loop • PRF setting for PW/CFM in Triplex
from a live or stored image Mode with user selectable ratio of 4S, M7C, 10L, and M12L
• M & A capability 1:1, 1:2, or 1:4 • 2 fundamental frequencies on 7L
• Not available for Linear transducers • Up to 4 B-mode harmonic settings:
Digital Power Doppler Imaging • Coded Harmonic Angio
Digital Spectral Doppler Mode • Power Doppler Maps: 10 maps • Coded Phase Inversion
• PW Acoustic Power: 0 – 100 % • 1 Directional map • Hi MI Harmonic
• PW Gain: 72 dB range, 1 dB step • Power Doppler Gain: 0-80 dB in • Coded Phase Inversion
• PW Displayed Dynamic Range: 24 – 1 dB steps • TruAgent Detection (3.5C, 4S)
40 dB, 4 dB step • PDI Frame Averaging: 7 steps • Multiple selections for CHA
• PW Gray Scale Map: 5 types • PDI Color Threshold: 0 - 100% tissue background
• PW Wall Filter: up to 10 steps, PRF • Wall Filter: 3 steps • Maximum Enhance Mode
(velocity scale) dependent • Simultaneous Real-time Triplex • The LOGIQ 9 is designed for
• PW Colorization: 4 steps Mode compatibility with commercially
• Color Tag B+PDI/PW in any depth, at any PRF available ultrasound contrast
• PRF: 1.0 – 30.0 kHz • PRF setting for PW/CFM in Triplex agents. Because the availability
• Velocity Scale Range: Mode with user selectable ratio of of these agents is subject to
• PD/HPRF +/- 5 m/sec (0°), 1:1, 1:2, or 1:4 government regulation and
+/- 10 m/sec (60°) • 8, 10, 12, 14 or 16 packets approval, product features
(Depending on the probe etc.) • Line Density: 3 steps intended for use with these agents
• Digital Wall Filter Frequency: 20 Hz
Auto Optimization may not be commercially
to 1800 Hz
• PW Sweep Speed: 8 types • Available in:
marketed nor made available
• Sample Volume Length: 1 – 16 mm • B-Mode before the contrast agent is
• Angle Correction: ± 0-90°, 1° step • B-Flow cleared for use. Contrast related
Available before Freeze and after • PW Doppler product features are enabled only
Freeze on systems for delivery to an
• Steered Linear: 0° - 20° B-Flow (option) authorized country or region of
(Depending on the probe) • Available on the following probes: use. GE Medical Systems makes
• Spectrum Inversion • 7L no claims concerning the safety
• Baseline Shift: 9 steps • 10L or effectiveness of contrast
• Doppler Auto Trace • i12L agents.
• Time Resolution: 2 to 25 msec, • M12L
typically 10 msec • M7C LOGIQView
• 3.5C • For use in B-Mode
Digital Color Flow Mode • E8C • LOGIQView Status
• Symmetrical Velocity Imaging • 8C • Auto detection of scan direction
for optimized 3D color images • Image Reverse: left/right • Pre or post-process zoom up to
• Color Maps: 8 velocity maps; • B-Flow sensitivity: 5 steps 10X
4 velocity-variance maps • Background ON/OFF • Rotation
• CFM Gain: 80 dB range, 1 dB steps • Displayed Dynamic Range: 36 – 102 • Auto best fit on monitor
• CFM Velocity Scale Range: dB • Measurements in B-Mode
- less than +/- 0.2 cm/s • Line Density: 3 steps • Up to 60 cm scan length
- max: +/- 3.0 m/s • Frame Averaging: 7 steps
• Wall Filter: 40 – 3500 Hz • Map: 18 selectable
3D (options)
• 8, 10, 12, 14 or 16 packets • Edge Enhance: 6 steps Advanced 3D
• Line Density: 3 steps • Flow Settings: Low / High • Acquisition of Color data
• CFM Spatial Filter: 6 selections • Automatic rendering

LOGIQ 9 Product Data Sheet 2350082GSP Rev. 3 Page 4 of 6


• 3D Landscape technology Real-time Doppler Auto Shephard, Hadlock, Hohler,
• 3D Movie Measurements / Calculations Campbell
• Main Mode • PS (Peak Systole) • Fetal Graphical Trending
• ED (End Diastole) • Growth Percentiles
Tru3D • MD (Minimum Diastole) • Multi-Gestational Calculations (4)
• Sensor-based acquisition • PI (Pulsatility Index) • Fetal Qualitative Description
• Display of data in: Main-, Parallel-, • RI (Resistivity Index) (Anatomical survey)
Angular-Mode • AT (Acceleration Time) • Fetal Environmental Description
• Render Modes: Gray Surface, • ACC (Acceleration) (Biophysical profile)
Texture, Min-, Max-, Average- • PS/ED (PS/ED Ratio) • Programmable OB Tables
Intensity • ED/PS (ED/PS Ratio) • Over 20 selectable OB Calcs
• Basic measurements: distance, angle, • HR (Heart Rate) • Expanded Worksheets
area • TAMAX (Time Averaged Maximum
• Volume measurements GYN Measurements/
Velocity)
• 3D Movie • PVAL (Peak Velocity Value) Calculations
• Volume Flow (TAMEAN and Vessel • Right Ovary Length, Width, Height
Area) • Left Ovary Length, Width, Height
Virtual Convex • Uterus Length, Width, Height
• Provides a convex field of view for OB Measurements / Calculations • Ovarian Volume
all linear and sector transducers • Gestational Age by: • ENDO (Endometrial thickness)
• M12L − GS (Gestational Sac) • Ovarian RI
• 10L • Uterine RI
− CRL (Crown Rump Length)
• 7L • Follicular measurements
• i12L − FL (Femur Length)
• Summary Reports
• 4S − BPD (Biparietal Diameter)
• 10S − AC (Abdominal Circumference) Vascular
− HC (Head Circumference) Measurements/Calculations
− APTD x TTD (Anterior/Posterior • SYS DCCA (Systolic Distal
Measurements / Trunk Diameter by Transverse Common Carotid Artery)
Trunk Diameter) • DIAS DCCA (Diastolic Distal
Calculations − LV (Length of Vertebra) Common Carotid Artery)
− FTA (Fetal Trunk Cross-sectional • SYS MCCA (Systolic Mid Common
General B-Mode Carotid Artery)
Area)
• Depth & Distance • DIAS MCCA (Diastolic Mid
• Circumference (Ellipse / Trace) − HL (Humerus Length)
− BD (Binocular Distance) Common Carotid Artery)
• Area (Ellipse / Trace) • SYS PCCA (Systolic Proximal
• Volume (Ellipsoid) − FT (Foot Length)
Common Carotid Artery)
• % Stenosis (Area or Diameter) − OFD (Occipital Frontal Diameter) • DIAS PCCA (Diastolic Proximal
• Angle between two lines − TAD (Transverse Abdominal Common Carotid Artery)
Diameter) • SYS DICA (Systolic Distal Internal
General M-Mode − TCD (Transverse Cerebellum Carotid Artery)
• M-Depth Diameter) • DIAS DICA (Systolic Distal Internal
• Distance
− THD (Thorax Transverse Carotid Artery)
• Time
Diameter) • SYS MICA (Systolic Mid Internal
• Slope
• Heart Rate − TIB (Tibia Length) Carotid Artery)
− ULNA (Ulna Length) • DIAS MICA (Diastolic Mid Internal
General Doppler • Estimated Fetal Weight (EFW) by: Carotid Artery)
Measurements/Calculations − AC, BPD • SYS PICA (Systolic Proximal
• Velocity − AC, BPD, FL Internal Carotid Artery)
• Time • DIAS PICA (Diastolic Proximal
− AC, BPD, FL, HC
• A/B Ratio (Velocities / Frequency Internal Carotid Artery)
− AC, FL • SYS DECA (Systolic Distal External
Ratio − AC, FL, HC
• PS (Peak Systole) Carotid Artery)
− AC, HC • DIAS DECA (Diastolic Distal
• ED (End Diastole)
• Calculations and Ratios External Carotid Artery)
• PS/ED (PS/ED Ratio)
• ED/PS (ED/PS Ratio) − FL/BPD • SYS PECA (Systolic Proximal
• AT (Acceleration Time) − FL/AC External Carotid Artery)
• ACCEL (Acceleration) − FL/HC • DIAS PECA (Diastolic Proximal
• TAMAX (Time Averaged Maximum − HC/AC External Carotid Artery)
Velocity − CI (Cephalic Index) • VERT (Systolic Vertebral Velocity)
• Volume Flow (TAMEAN and Vessel − AFI (Amniotic Fluid Index) • SUBCLAV (Systolic Subclavian
Area) • Measurements / Calculations by: Velocity)
• Heart Rate Jeanty, Merz, Tokyo University, • Summary Reports
• PI (Pulsatility Index) Mercer, Hansmann, Erickson, Hill,
• RI (Resistivity Index)

LOGIQ 9 Product Data Sheet 2350082GSP Rev. 3 Page 5 of 6


• Doppler Transmission Frequency: • M12L Matrix Array Wide Band
Probes 1.9 MHz Linear Probe
• 3.5C Wide Band Convex Probe • Harmonic Frequency: 4 MHz • Applications: Small Parts,
• Applications: Abdomen, OB/Gyn, • Biopsy Guide Available: Not Vascular, Neonatal, Pediatrics
Urology, Vascular Available • Maximum Band Width (-20dB):
• Maximum Band Width (-20dB): 5- 13 MHz
2 – 5 MHz • 10S Wide Band Sector Probe • Number of Elements: 960
• Number of Elements: 128 • Applications: Neonatal, Small • FOV: 39 mm
• Convex Radius: 40 mm Parts, Abdomen, Pediatrics • Foot Print: 45 x 10 mm
• FOV: 68° • Maximum Band Width (-20dB): • Doppler Transmission Frequency:
• Foot Print: 53 x 18 mm 4.0 – 11.0 MHz 5.6 MHz
• Doppler Transmission Frequency: • Number of Elements: 96 • Harmonic Frequency: 10.0 MHz
2.5 MHz • FOV: 90° • Biopsy Guide Available: Multi-
• Harmonic Frequency: 4 MHz • Foot Print: 14 x 11 mm Angle, Reusable
• Biopsy Guide Available: Single- • Doppler Transmission Frequency:
Angle, Reusable 5.0 MHz
• Harmonic Frequency: 10.0 MHz External Inputs and
• M7C Matrix Array Wide Band • Biopsy Guide Available: Not
Convex Probe
• Applications: Abdomen, OB/Gyn,
Available Outputs (not including on-board
peripherals)
Pediatrics • i12L Intraoperative Wide Band
• Maximum Band Width (-20dB): Linear Probe • Video Out
3 – 8 MHz • Applications: Intraoperative, Small • SVGA
• Number of Elements: 960 Parts, Vascular, Pediatrics • Composite Color
• Convex Radius: 50 mm • Maximum Band Width (-20dB): • Composite b/w
• FOV: 63° 5 – 12 MHz • S-Video
• Foot Print: 55 x 18 mm • Number of Elements: 96
• Doppler Transmission Frequency: • Audio Stereo Out
• FOV: 25 mm • Remote Expose (2)
3.1 MHz • Foot Print: 29 x 10 mm
• Harmonic Frequency: 7 MHz • 3 Position Footswitch
• Doppler Transmission Frequency: • RS-232 serial port for Line Printer
• Biopsy Guide Available: Multi- 5.0 MHz
angle, reusable • Ethernet
• Harmonic Frequency: 10.0 MHz • External microphone
• Biopsy Guide Available: Not • InsiteTM Modem Connection
• E8C Wide Band Microconvex Probe Available
• Applications: OB/Gyn • iLinq Modem Connection
• Maximum Band Width (-20dB): • 7L Wide Band Linear Probe
4 – 11 MHz • Applications: Vascular, Small
• Number of Elements: 128 Parts Safety Conformance
• Convex Radius: 11 mm • Maximum Band Width (-20dB):
• FOV: 133° 3 – 7 MHz The LOGIQ 9 is:
• Foot Print: 23 x 10x mm • Number of Elements: 192 • Listed to UL 2601-1 by a Nationally
• Doppler Transmission Frequency: • FOV: 46 mm Recognized Test Lab
4.4 MHz • Foot Print: 52 x 10 mm • Certified to CSA 22.2, 60601.1 by an
• Harmonic Frequency: 8 MHz • Doppler Transmission Frequency: SCC accredited Test Lab
• Biopsy Guide Available: Single 3.8 MHz • CE Marked to Council Directive
Angle, Disposable • Harmonic Frequency: 7.0 MHz 93/42/EEC on Medical Devices
• Steered Angle: Max. 20° • Conforms to the following standards
• 8C Wide Band Microconvex Probe • Biopsy Guide Available: Multi- for safety:
• Applications: Neonatal, Pediatrics Angle, Reusable • EN 60601-1 Electrical medical
Maximum Band Width (-20dB): equipment
4 – 11 MHz • 10L Wide Band Linear Probe • EN 60601-1-1 Electrical medical
• Number of Elements: 128 • Applications: Vascular, Small equipment
• Convex Radius: 11 mm Parts, Neonatal, Pediatrics • EN 60601-1-2 Electromagnetic
• FOV: 133° • Maximum Band Width (-20dB): compatibility
• Foot Print: 23 x 10x mm 4 – 10 MHz • EN 60601-1-4 Programmable
• Doppler Transmission Frequency: • Number of Elements: 192 medical systems
4.4 MHz • FOV: 39 mm • ISO 10993 Biological evaluation
• Harmonic Frequency: 8 MHz • Foot Print: 44 x 10 mm of medical devices
• Doppler Transmission Frequency: • NEMA UD3 Acoustic output
• 4S Wide Band Sector Probe 4.4 MHz display (MI, TIS, TIB, TIC)
• Applications: Abdomen, OB/Gyn, • Harmonic Frequency: 9.0 MHz
TCD • Steered Angle: Max. 20°
• Maximum Band Width(-20dB): • Biopsy Guide Available: Multi-
2 – 5 MHz Angle, Reusable
• Number of Elements: 128
• FOV: 90°
• Foot Print: 32 x 19 mm

LOGIQ 9 Product Data Sheet 2350082GSP Rev. 3 Page 6 of 6