Slab Reinforcement and Calculation Report

1. The document provides details on the reinforcement, concrete, geometry, loads, and calculation results for slab Panel no. 1. 2. The calculation results indicate that the provided reinforcement area is too small and punching requirements are not fulfilled at several verification points. 3. Maximum moments and required reinforcement areas are provided for bending in the X, Y, and XY directions, showing that the required areas greatly exceed the provided areas.

Uploaded by

maiductho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
411 views11 pages

Slab Reinforcement and Calculation Report

1. The document provides details on the reinforcement, concrete, geometry, loads, and calculation results for slab Panel no. 1. 2. The calculation results indicate that the provided reinforcement area is too small and punching requirements are not fulfilled at several verification points. 3. Maximum moments and required reinforcement areas are provided for bending in the X, Y, and XY directions, showing that the required areas greatly exceed the provided areas.

Uploaded by

maiductho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd

1. Slab: Plate1 - Panel no.

1
1.1. Reinforcement:

·0 Type : RC floor
·1 Main reinforcement direction : 0°
·2 Main reinforcement grade : B500C; Characteristic
strength = 500.00 MPa
Horizontal branch of the stress-strain diagram
·3 Ductility class :C
·4 Bar diameters bottom d1 = 1.2 (cm) d2 = 1.2 (cm)
top d1 = 1.2 (cm) d2 = 1.2 (cm)
·5 Cover bottom c1 = 3.0 (cm)
top c2 = 3.0 (cm)
·6 Cover deviations Cdev = 1.0(cm), Cdur = 0.0(cm)

1.2. Concrete

·7 Class : C25/30; Characteristic strength = 25.00


MPa
Rectangular stress distribution [3.1.7(3)]
·8 Density : 2501.36 (kG/m3)
·9 Concrete creep coefficient : 1.47
·10 Cement class :N

1.3. Hypothesis

·11 Calculations according


to : EN 1992-1-1:2004
AC:2008
·12 Method of
reinforcement area calculations : analytical
·13 Allowable cracking
width
- upper layer : 0.40 (mm)
- lower layer : 0.40 (mm)
·14 Allowable deflection
: 3.0 (cm)
·15 Verification of punching
: yes
·16 Exposure
- upper layer : X0
- lower layer : X0
·17 Calculation type : simple
bending
·18 Structure class : S1

1.4. Slab geometry


Thickness 0.35 (m)
Contour:
edge beginning end length
x1 y1 x2 y2 (m)
1 -7.00 5.00 7.00 5.00 14.00
2 7.00 5.00 7.00 -5.00 10.00
3 7.00 -5.00 -7.00 -5.00 14.00
4 -7.00 -5.00 -7.00 5.00 10.00

Support:
n° Name dimensions coordinates edge
(m) x y
107 point 0.40 / 0.40 -7.00 5.00 —
128 point 0.40 / 0.40 -7.00 -5.00 —
146 point 0.40 / 0.40 7.00 5.00 —
163 point 0.40 / 0.40 7.00 -5.00 —
* - head present

1.5. Calculation results:


It is impossible to obtain provided reinforcement with appropriate area
Too little top reinforcement area
Too little bottom reinforcement area
Punching requirements have not been fulfilled:
Verification point 1 - Too little safety factor - reinforcement required
Verification point 1 - The value of the punching force is too big
Verification point 2 - Too little safety factor - reinforcement required
Verification point 2 - The value of the punching force is too big
Verification point 3 - Too little safety factor - reinforcement required
Verification point 3 - The value of the punching force is too big
Verification point 4 - Too little safety factor - reinforcement required
Verification point 4 - The value of the punching force is too big
For top reinforcement in the direction of X axis at the point: (-6.68, 4.00)
Ar/At = 0.03 < 1.0
For top reinforcement in the direction of X axis at the point: (-6.68, -4.67)
Ar/At = 0.07 < 1.0
For top reinforcement in the direction of X axis at the point: (-6.68, -3.40)
Ar/At = 0.92 < 1.0
For top reinforcement in the direction of Y axis at the point: (-6.68, 4.00)
Ar/At = 0.05 < 1.0
For top reinforcement in the direction of Y axis at the point: (-6.68, -4.00)
Ar/At = 0.08 < 1.0
For top reinforcement in the direction of Y axis at the point: (-6.68, -4.67)
Ar/At = 0.10 < 1.0
For bottom reinforcement in the direction of X axis at the point: (-6.68, 4.00)
Ar/At = 0.04 < 1.0
For bottom reinforcement in the direction of X axis at the point: (-6.68,
-4.00) Ar/At = 0.04 < 1.0
For bottom reinforcement in the direction of X axis at the point: (-6.68,
-3.40) Ar/At = 0.21 < 1.0
For bottom reinforcement in the direction of Y axis at the point: (-6.68, 4.00)
Ar/At = 0.07 < 1.0
For bottom reinforcement in the direction of Y axis at the point: (-6.68,
-4.00) Ar/At = 0.07 < 1.0
For bottom reinforcement in the direction of Y axis at the point: (-6.68,
-2.75) Ar/At = 0.54 < 1.0
1.5.1. Maximum moments + reinforcement for bending

Ax(+) Ax(-) Ay(+)


Ay(-)
Provided reinforcement (cm2/m):
10.46 10.46 10.46
10.46
Modified required reinforcement (cm2/m):
301.12 269.61 200.38
159.55
Original required reinforcement (cm2/m):
369.45 312.35 248.40
192.76
Coordinates (m):
-7.00;5.00 -7.00;5.00 -7.00;5.00
-7.00;5.00

1.5.2. Maximum moments + reinforcement for bending

Ax(+) Ax(-) Ay(+)


Ay(-)
Symbol: required area/provided area
Ax(+) (cm2/m) 301.12*/10.46 301.12*/10.46 301.12*/10.46
301.12*/10.46
Ax(-) (cm2/m) 269.61*/10.46 269.61*/10.46 269.61*/10.46
269.61*/10.46
Ay(+) (cm2/m) 200.38*/10.46 200.38*/10.46 200.38*/10.46
200.38*/10.46
Ay(-) (cm2/m) 159.55*/10.46 159.55*/10.46 159.55*/10.46
159.55*/10.46
* - Reinforcement area reduced to support contour

ULS
Mxx (kN*m/m) 3085.25 3085.25 3085.25
3085.25
Myy (kN*m/m) 1754.49 1754.49 1754.49
1754.49
Mxy (kN*m/m) -840.50 -840.50 -840.50
-840.50

Coordinates (m) -7.00;5.00 -7.00;5.00 -7.00;5.00


-7.00;5.00
Coordinates* (m) -7.00;5.00;0.00 -7.00;5.00;0.00 -7.00;5.00;0.00
-7.00;5.00;0.00
* - Coordinates in the structure global coordinate system

1.5.3. Punching
Support no. / Point Location (m) Geometry: (m)
x y a b d h
S1 -7.00 5.00 Column 0.40 0.40 -
-
S2 -7.00 -5.00 Column 0.40 0.40 -
-
S3 7.00 5.00 Column 0.40 0.40 -
-
S4 7.00 -5.00 Column 0.40 0.40 -
-

Support no. / Point Loads: (kN) Critical perimeter (m)


Q Qadm u Qadm / Q
S1 4998.39 317.96 2.34 0.06 < 1
S2 5007.58 317.96 2.34 0.06 < 1
S3 4968.83 317.96 2.34 0.06 < 1
S4 4983.52 317.96 2.34 0.06 < 1

Punching requirements not fulfilled for points: S1, S2, S3, S4,
Support no. / Point: S1
uo = 0.60
u1 = 2.34
rLx = 0.00
rLy = 0.00
heff = 30.8 (cm)
Ax = 10.46 (cm2)
Ay = 10.46 (cm2)
a= 1.57
n= 0.54 ()
gc = 1.50 ()
fcd = 16.67 (MPa)
vRdmax = 4.50 (MPa)
V= 784.30 (kN)
Mx = 575.95 (kN*m)
My = 1009.41 (kN*m)
A= 0.42 (m2)
Kx = 0.60
Ky = 0.60
Wx = 0.10
Wy = 0.10

vRdc = 0.44
nmin = 0.42
vEds = 27.05
cRdc= 0.12
k= 1.81
rL = 0.00 ()
vlim = 0.44 (MPa)
v= 6.95 (MPa)
A= 0.72 (m2)

Support no. / Point: S2


uo = 0.60
u1 = 2.34
rLx = 0.00
rLy = 0.00
heff = 30.8 (cm)
Ax = 10.46 (cm2)
Ay = 10.46 (cm2)
a= 1.57
n= 0.54 ()
gc = 1.50 ()
fcd = 16.67 (MPa)
vRdmax = 4.50 (MPa)
V= 807.23 (kN)
Mx = 573.07 (kN*m)
My = 1007.13 (kN*m)
A= 0.42 (m2)
Kx = 0.60
Ky = 0.60
Wx = 0.10
Wy = 0.10

vRdc = 0.44
nmin = 0.42
vEds = 27.10
cRdc= 0.12
k= 1.81
rL = 0.00 ()
vlim = 0.44 (MPa)
v= 6.96 (MPa)
A= 0.72 (m2)

Support no. / Point: S3


uo = 0.60
u1 = 2.34
rLx = 0.00
rLy = 0.00
heff = 30.8 (cm)
Ax = 10.46 (cm2)
Ay = 10.46 (cm2)
a= 1.57
n= 0.54 ()
gc = 1.50 ()
fcd = 16.67 (MPa)
vRdmax = 4.50 (MPa)
V= 817.19 (kN)
Mx = 566.46 (kN*m)
My = 995.41 (kN*m)
A= 0.42 (m2)
Kx = 0.60
Ky = 0.60
Wx = 0.10
Wy = 0.10

vRdc = 0.44
nmin = 0.42
vEds = 26.89
cRdc= 0.12
k= 1.81
rL = 0.00 ()
vlim = 0.44 (MPa)
v= 6.91 (MPa)
A= 0.72 (m2)

Support no. / Point: S4


uo = 0.60
u1 = 2.34
rLx = 0.00
rLy = 0.00
heff = 30.8 (cm)
Ax = 10.46 (cm2)
Ay = 10.46 (cm2)
a= 1.57
n= 0.54 ()
gc = 1.50 ()
fcd = 16.67 (MPa)
vRdmax = 4.50 (MPa)
V= 822.74 (kN)
Mx = 567.05 (kN*m)
My = 998.26 (kN*m)
A= 0.42 (m2)
Kx = 0.60
Ky = 0.60
Wx = 0.10
Wy = 0.10

vRdc = 0.44
nmin = 0.42
vEds = 26.97
cRdc= 0.12
k= 1.81
rL = 0.00 ()
vlim = 0.44 (MPa)
v= 6.93 (MPa)
A= 0.72 (m2)
1.5.4. Deflection
|f(+)| = 0.0 (cm) <= fdop(+) = 3.0 (cm)
|f(-)| = 0.0 (cm) <= fdop(-) = 3.0 (cm)

1.5.5. Cracking
upper layer
ax = 0.00 (mm) <= adop = 0.40 (mm)
ay = 0.00 (mm) <= adop = 0.40 (mm)
lower layer
ax = 0.00 (mm) <= adop = 0.40 (mm)
ay = 0.00 (mm) <= adop = 0.40 (mm)

2. Loads:
Case Type List Value
1 self-weight 1 PZ Negative
1 (FE) uniform 1 PZ=-6.50(kN/m2)
2 (FE) uniform 1 PZ=-2.50(kN/m2)

Combination/Component Definition
ULS/3 1*1.35+2*1.50

3. Results - detailing
List of solutions:
Reinforcement: Wire fabrics
Solution no. Wire fabric no./type Re-usability coefficient (percent) Total
Weight
(kG)
1 56 x 10-150,5000x2350 92.98 5139.13

Results for the solution no. 1


Reinforcement zones

Bottom reinforcement
Name coordinates Provided reinforcement At
Ar At Ar
x1 y1 x2 y2
(cm2/m) (cm2/m) (cm2/m)
(cm2/m)
1/1- -7.00 5.00 7.00 1.33 10-150,5000x2350 10-
150,5000x2350 269.61 > 10.46 159.55 > 10.46
1/2- -7.00 1.82 -3.40 0.18 10-150,5000x2350 10-
150,5000x2350 27.08 > 10.46 37.99 > 10.46
1/3- -1.60 1.82 7.00 0.18 10-150,5000x2350 10-
150,5000x2350 62.36 > 10.46 33.74 > 10.46
1/4- -7.00 0.67 7.00 -5.00 10-150,5000x2350 10-
150,5000x2350 268.37 > 10.46 158.27 > 10.46

Top reinforcement
Name coordinates Provided reinforcement At
Ar At Ar
x1 y1 x2 y2
(cm2/m) (cm2/m) (cm2/m)
(cm2/m)
1/1+ -7.00 5.00 -3.40 2.11 10-150,5000x2350 5.23
< 5.23 5.23 < 5.23
1/2+ -7.00 5.00 -0.33 2.11 10-150,5000x2350
295.89 > 5.23 195.15 > 5.23
1/3+ 1.00 5.00 7.00 3.20 10-150,5000x2350 5.23
< 5.23 5.23 < 5.23
1/4+ 3.00 5.00 7.00 2.60 10-150,5000x2350
291.26 > 5.23 191.63 > 5.23
1/5+ 4.33 3.69 7.00 1.33 10-150,5000x2350
24.15 > 5.23 4.26 < 5.23
1/6+ -7.00 3.09 -5.20 0.84 10-150,5000x2350 5.23
< 5.23 0.00 < 5.23
1/7+ -7.00 2.60 0.33 1.33 10-150,5000x2350 9.64
> 5.23 4.52 < 5.23
1/8+ -1.60 2.60 0.33 -1.12 10-150,5000x2350 5.23
< 5.23 4.52 < 5.23
1/9+ -7.00 1.82 -3.40 0.18 10-150,5000x2350 4.69
< 5.23 0.00 < 5.23
1/10+ -1.60 1.82 0.33 0.18 10-150,5000x2350 4.11
< 5.23 0.00 < 5.23
1/11+ 5.00 3.09 7.00 -2.99 10-150,5000x2350
11.53 > 5.23 0.00 < 5.23
1/12+ -7.00 0.67 0.33 -0.62 10-150,5000x2350 4.69
< 5.23 4.52 < 5.23
1/13+ -7.00 -0.13 -5.20 -2.99 10-150,5000x2350 5.23
< 5.23 0.00 < 5.23
1/14+ -4.60 -0.13 -0.33 -1.25 10-150,5000x2350 0.00
< 5.23 4.52 < 5.23
1/15+ -7.00 -1.25 -5.20 -2.99 10-150,5000x2350
10.04 > 5.23 0.00 < 5.23
1/16+ 4.33 -1.25 7.00 -3.62 10-150,5000x2350
11.68 > 5.23 5.23 > 5.23
1/17+ -7.00 -2.50 -4.00 -3.62 10-150,5000x2350 5.23
< 5.23 5.23 < 5.23
1/18+ -7.00 -2.50 -3.40 -5.00 10-150,5000x2350
23.14 > 5.23 5.23 > 5.23
1/19+ 3.00 -2.50 7.00 -5.00 10-150,5000x2350
24.29 > 5.23 5.23 > 5.23
1/20+ -7.00 -3.13 -0.33 -5.00 10-150,5000x2350
294.81 > 5.23 194.13 > 5.23
1/21+ 1.00 -3.13 7.00 -5.00 10-150,5000x2350
292.00 > 5.23 191.88 > 5.23

Insufficient top reinforcement area.


Insufficient bottom reinforcement area.

4. Material survey
·19 Concrete volume = 49.00 (m3)
·20 Formwork = 140.00 (m2)
·21 Slab circumference = 48.00
(m)
·22 Area of openings = 6.00 (m2)

·23 Steel B500C


·24 Total weight = 31.48 (kG)
·25 Density = 0.64 (kG/m3)
·26 Average diameter = 10.0 (mm)
·27 Survey according to diameters:

Diameter Length Number:


(m)
10 3.19 16

·28 Wire fabrics


·29 Weight of used reinforcement
= 5139.13 (kG)
·30 Reinforcement total weight
= 5526.85 (kG)
·31 Density = 104.88 (kG/m3)
·32 Re-usability coefficient (percent):
Weight = 7.02
- area = 7.02
·33 Global survey:

Symbol/Type Number Weight


(No.) (kG)
10-150,5000x2350 / B 500K 56 5526.85

·34 Detailed survey:

Panel
Number Symbol/Type Pos. Dimension Cut Number
in panel
(No.) Lr / lr (m) (No.)

4 10-150,5000x2350 / B 500K 1 3.33 / 2.35 2/3 | 1/1


1
28 1.67 / 2.35 1/3 | 1/1 1

1 10-150,5000x2350 / B 500K 20 1.67 / 1.57 1/3 | 2/3


1
68 3.94 / 0.57 -|- 1
10 1.34 / 1.57 - | 2/3 2
2 0.61 / 2.35 - | 1/1 1

1 10-150,5000x2350 / B 500K 36 0.67 / 2.35 - | 1/1 1


27 2.67 / 0.58 -|- 1
2 0.61 / 2.35 - | 1/1 1
17 0.51 / 2.35 - | 1/1 2
62 1.34 / 0.80 -|- 1
45 1.27 / 0.78 - | 1/3 1
12 1.34 / 0.72 -|- 1
53 0.84 / 0.78 - | 1/3 1

1 10-150,5000x2350 / B 500K 25 2.67 / 1.17 - | 1/2 2


20 1.67 / 1.57 1/3 | 2/3 1
2 0.61 / 2.35 - | 1/1 1
48 1.67 / 0.66 1/3 | - 1

1 10-150,5000x2350 / B 500K 60 5.00 / 0.80 1/1 | - 1


3 3.33 / 1.03 2/3 | - 1
22 1.67 / 1.17 1/3 | - 1

1 10-150,5000x2350 / B 500K 30 0.61 / 1.86 -|- 1


41 0.47 / 2.35 - | 1/1 1
32 0.61 / 1.57 - | 2/3 3
35 1.67 / 0.57 1/3 | - 1
21 0.47 / 1.57 - | 2/3 2
58 1.01 / 0.64 -|- 1
4 0.61 / 1.03 -|- 1
43 0.47 / 1.00 -|- 1
34 0.61 / 0.57 -|- 2

13 10-150,5000x2350 / B 500K 5 5.00 / 2.35 1/1 | 1/1


1

1 10-150,5000x2350 / B 500K 6 2.01 / 2.35 - | 1/1 1


59 2.01 / 1.57 - | 2/3 1
52 2.50 / 0.78 1/2 | 1/3 1
32 0.61 / 1.57 - | 2/3 1
49 0.47 / 0.66 -|- 1

1 10-150,5000x2350 / B 500K 7 5.00 / 1.03 1/1 | - 1


60 5.00 / 0.80 1/1 | - 1

1 10-150,5000x2350 / B 500K 8 2.01 / 1.03 -|- 1


52 2.50 / 0.78 1/2 | 1/3 1
42 1.67 / 1.00 1/3 | - 1
61 2.01 / 0.80 -|- 1
45 1.27 / 0.78 - | 1/3 1
23 0.47 / 1.17 -|- 1

1 10-150,5000x2350 / B 500K 9 5.00 / 1.57 1/1 | 2/3


1
11 5.00 / 0.72 1/1 | - 1

1 10-150,5000x2350 / B 500K 9 5.00 / 1.57 1/1 | 2/3


1
26 5.00 / 0.58 1/1 | - 1
1 10-150,5000x2350 / B 500K 9 5.00 / 1.57 1/1 | 2/3
1
39 5.00 / 0.61 1/1 | - 1

2 10-150,5000x2350 / B 500K 9 5.00 / 1.57 1/1 | 2/3


1
67 5.00 / 0.57 1/1 | - 1

1 10-150,5000x2350 / B 500K 66 3.94 / 1.57 - | 2/3 1


44 3.33 / 0.78 2/3 | 1/3 1
13 1.01 / 2.35 - | 1/1 1
34 0.61 / 0.57 -|- 1

1 10-150,5000x2350 / B 500K 66 3.94 / 1.57 - | 2/3 1


44 3.33 / 0.78 2/3 | 1/3 1
13 1.01 / 2.35 - | 1/1 1
57 0.61 / 0.64 -|- 1

1 10-150,5000x2350 / B 500K 64 5.00 / 1.81 1/1 | - 1


14 3.33 / 0.54 2/3 | - 1
37 1.67 / 0.50 1/3 | - 1

1 10-150,5000x2350 / B 500K 64 5.00 / 1.81 1/1 | - 1


18 2.50 / 0.50 1/2 | - 1
15 1.01 / 0.54 -|- 1
55 0.84 / 0.53 -|- 1
51 0.51 / 0.51 -|- 1

1 10-150,5000x2350 / B 500K 16 2.50 / 2.35 1/2 | 1/1


2

1 10-150,5000x2350 / B 500K 65 4.68 / 1.81 -|- 1


38 0.67 / 0.50 -|- 1
19 0.51 / 0.50 -|- 1

1 10-150,5000x2350 / B 500K 31 3.33 / 1.57 2/3 | 2/3


1
20 1.67 / 1.57 1/3 | 2/3 1
68 3.94 / 0.57 -|- 1
53 0.84 / 0.78 - | 1/3 1

1 10-150,5000x2350 / B 500K 24 5.00 / 1.17 1/1 | 1/2


2

1 10-150,5000x2350 / B 500K 31 3.33 / 1.57 2/3 | 2/3


1
28 1.67 / 2.35 1/3 | 1/1 1
56 3.33 / 0.64 2/3 | - 1

1 10-150,5000x2350 / B 500K 31 3.33 / 1.57 2/3 | 2/3


1
29 1.67 / 1.86 1/3 | - 1
56 3.33 / 0.64 2/3 | - 1

1 10-150,5000x2350 / B 500K 33 3.33 / 0.57 2/3 | - 3


40 2.67 / 0.61 -|- 1
36 0.67 / 2.35 - | 1/1 2
34 0.61 / 0.57 -|- 1

1 10-150,5000x2350 / B 500K 64 5.00 / 1.81 1/1 | - 1


46 3.33 / 0.53 2/3 | - 1
47 1.27 / 0.53 -|- 1

1 10-150,5000x2350 / B 500K 64 5.00 / 1.81 1/1 | - 1


54 2.50 / 0.53 1/2 | - 1
50 2.50 / 0.51 1/2 | - 1

6 10-150,5000x2350 / B 500K 63 4.68 / 2.35 - | 1/1 1

1 10-150,5000x2350 / B 500K 65 4.68 / 1.81 -|- 1

4 10-150,5000x2350 / B 500K 69 5.00 / 1.95 1/1 | - 1

2 10-150,5000x2350 / B 500K 70 4.68 / 1.95 -|- 1

You might also like