ANALYSIS OF BIAXIALLY LOADED RECTANGULAR COLUMN:
EQUIVALENT ECCENTRICITY METHOD
based from ACI 318-14
Programmed by: ENGR. RYAN M. LAYUG | ryanmlayug@[Link]
A. INPUT DATA
Column Section:
C1: 350mm x 350mm, 12-16mm ϕ
Strength Parameters: Column Dimension:
fy ≔ 230 MPa b ≔ 350 mm
fc' ≔ 20.7 MPa h ≔ 350 mm
Es ≔ 200000 MPa
εc ≔ 0.003
Longitudinal Reinforcement:
db ≔ 16 mm ⎡1 1 1 1⎤
⎢1 0 0 1⎥
ds ≔ 10 mm nb ≔ ⎢ ⎥
⎢1 0 0 1⎥
concrete_cover ≔ 40 mm ⎣1 1 1 1⎦
Loads:
Pu ≔ 180 kN
Mux ≔ 45 kN ⋅ m
Muy ≔ 24 kN ⋅ m
350
315
280
245
210
175
140
105
70
35
0
0 35 70 105 140 175 210 245 280 315 350
Steel_Ratio = “OK”
steel_ratio_perentage = 1.97
Project Name: Owner:
Location: Civil Engineer / Designer: Page 1 of 2
rebar_clear_spacing_along_base = 62 mm
rebar_clear_spacing_along_height = 62 mm
B. ANALYSIS
Pu0 = 180 kN
eo = 330 mm
Muo = 59.4 kN ⋅ m
Equivalent_Eccentricity = “Bending about X”
Note: This method is only applicable if the ratio of the longest to shortest cross-sectional dimension is in the range of 1 to 2.
C. INTERACTION DIAGRAM - BENDING ABOUT X AXIS
D. INTERACTION DIAGRAM - BENDING ABOUT Y AXIS
2000
1750
1500
1250
1000
750
500
250
0
-120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120
-250
-500
Project Name: Owner: