GE Oil & Gas
Measurment Solutions
GE Measurement & Sensing USM Product
Portfolio
Flowmeters
Liquid Gas / Steam
Wetted Clamp-on Portable Wetted Clamp-on Portable
Process High
CT Water cut Steam Flare
Gas Pressure
Ultrasonic Flow Measurement Technology
• Transit Time
• Delta T ~ Velocity
P
u
l
s
eRe
c
e
i
ve
dD
o
w
n
st
r
ea
m
• High Turndown P
u
l
s
eRe
c
e
i
ve
dU
p
s
t
r
ea
m
t
• Zero Pressure Drop
0 1
9
0
0 2
0
0
0 2
1
0
0 2
2
0
0
T
i
me
si
n
cef
i
r
in
g
(
se
c)
Ultrasonic Solution Features & Benefits
• Features • Benefits
• No obstruction to the flow
• No need to purge lines
• Nothing to wear and tear
• No maintenance required
• No pressure drop
• Increased efficiency
• Accurate (±0.5% to 1% of the mv)
and drift free • No recalibration needed
• Diagnostics and Errors flagged
xxxxxx
• Low cost of ownership • Reliability
• SIL certified meters by design with • Low OPEX
redudant sensors and electronics • Safety and reliability
Multivariable Vortex Flow
PanaFlow MV80
• In-line series • Wide flow range in gas and steam
• Multivariable vortex technology • Low operational costs
• Mass flow with Temp and Pressure • Little to no maintenance
built in • Good alternative to DP
• Targeted for steam and gas • Only loop powered mass vortex
• Small pipes
PanaFlow MV82
• Insertion style • Wide flow range
• Hot tap and cold tap • Lower cost for large pipes
• Target to larger pipes
• Lower accuracy to inline
• Same applications as inline
GE Difference:
• Offers both inline and insertion styles
• Only loop powered mass flow vortex
• Complimentary portfolio with USM on steam
Vortex Flow Meters
• Vortex – eddy of fluid
f pulses/sec
Frequency (f ):
Frequency of vortices generated in a
vortex meter, Hz
Wavelength
Distance between vortices = constant
Velocity sensor
Vortex shedder bar Vortices
Flow
Constant
wave length
Vortex Flow Meters
Which one to use?
MV80 MV82
Accuracy Vol(Liquid): 0.7% - Mass:(Liquid): 1.0% Vol(Liquid): 1.2% - Mass:(Liquid): 1.5%
Vol(Gas): 1.0% - Mass:(Gas): 1.5% Vol(Gas): 1.5% - Mass:(Gas): 2.0%
Line Sizes ½” to 8” 2” to 72”
Installation • Permanent • Permanent or Retractable
• Cold tap only • Cold or hot tap
• Inline • Insertion
– Flanged or Wafer – Compression or Packing Gland
– Piping/flowcell type install – Requires nozzle (weldolet and WN
flange
– Valve required with packing gland
(retractable) system
• One meter for any size!
Vortex Flow Meters
Volumetric Meter Temperature and Pressure Compensation :
Inexpensive option More than just a multi-variable
Liquid applications
Multiparameter Meter Ability to dynamically calculate
Multiple outputs density and to adjust for low Re
3 analog, 3 alarm, 1 pulse and numbers below 10,000 –
HART remember the curve
Options– Modbus, EMS ( Energy) Ability to measure mass flow with a
Optional – loop powered – two wire single penetration
VT – used for liquids and Saturated Multiple outputs from a single
Steam penetration
VTP - used on gas and steam
Energy option
Input options – temperature, pressure,
alarm, etc.
Temperatures up to 750 deg F (400 deg C)
Custody Transfer
Sentinel LNG, LCT & LCT4
9
Ultrasonic High Accuracy Meters
• Normal liquid applications • OIML certified
• Crude • 0.15% uncertainty
Sentinel LCT/LCT4 • Refined petroleum • Viscosity independent
• Water • Detailed diagnostics
• Custody transfer • No pressure drop
• Leak detection • Temperature compensated
• Allocation • Wide measurement range
• Critical process • Excellent low end resolution
Sentinel LNG
• Cryogenic applications • OIML tested
• Liquefied natural gas • 0.25% uncertainty
• Liquefied petroleum • Measures down to -190ºC
gas • Proven BWT technology
• Custody transfer • No pressure drop
• Allocation
Sentinel LCT4
Field Applications
8" Sentinel LCT4 for oil metering on a metering skid using a ball prover
Global Installed Base
Clamp-ON
16
Liquid Flow Meters Liquid Electronics
PT878
Portable liquid flowmeter
General purpose locations
Full function keypad
Rugged compact design
4-20 and Frequency outputs
Clamp-on technology
Target markets:
All flow areas
Inline meter verification
Facility auditing
AT600
AT600 Summary
A liquid US clamp on meter
© AT600 Electronics
© Transducer cable
© Transducers
© Mounting Fixture
AT600
AT600 Electronics
• Easy wiring with clean internal design
• SMB connector of transducer wiring
• 4-20 mA with two discrete outputs
• Modbus/RS485 and HART optional
• Vitality software capable
• 85 to 265 VAC or 12 to 28 VDC
AT600 New Transducers and Fixture
On the pipe in minutes
• Quick-tighten stainless strapping • Simple adjustment and alignment
• Pre-installed transducers • Anodized aluminum
• Easy-to-read spacing markings • Lightweight
CTF878 – clamp on gas measurement
Clamp-on flowmeter for gases : air hidrocarbons, natural gas with minimum density 1.2kg/m3
-Minimum pressure 0.7 barg
-Pipe Sizes 6” to 30”
-Wall thickness up to Sch 80
-Velocity Accuracy: 2% of reading
Clamp On Gas on gas drilling well’s
Natural Gas storage Okoli , Croatia
Clamp On Gas
Natural gas processing plant
Clamp-On Flow on 4” CS line
at 90 bar
Clamp On Gas
Underground Storage
GC868 Clamp-On Gas
10” Duplex
200bar
Natural Gas
Experience with Natural Gas
NG wells: GC868 + CRV 310 on 3" 6.2mm, 80 bar
Pre tested using PT878GC
Clamp On Gas
Gas Transmission Pipeline
GC868 Clamp-On Gas
DN 800, 1200 and
1400mm
CS
78bar
Natural Gas
Clamp On Gas
Natural Gas Treatment Plant
CTF878 Clamp-On fuel gas
10 ft/s velocity
6 in, sch 40 CS pipe
High Temperature Flow
Measurement
28
PanaFlow HT The background
1997/1998: Shell NL Pernis
Per+ project (heavy resid)
T°: 150°C to 385°C
Pressure: up to 78 Bar
2001: Houston, TX Sweeny
Delayed Coker furnace feed
with redundant
measurements
PanaFlow HT Wave Guide
•Bundle Waveguide TechnologyTM (BWT)
Piezoelement Piezoelement
Solid Bundled
Buffer Waveguide
Piezoelement
Temp = -200 to Temp = -200 to Temp = -200 to
600C 600C 600C
Traditional – No Buffer Traditional – Solid Bundled Waveguide
Buffer
• Advantages of buffers
- Transducers are outside of the extreme
temperatures
- Avoids thermal shock with risk of cracking crystal
- Transducers can be replaced under operations
PanaFlow HT: The Outcome SIL for Safety First
Advantages of PanaFlow HT SIL2 or SIL3
A SIL rated meter….
SIL PFD RRF Process Control Safety Instrumented
System System (or ESD)
SIL 4 10-5 to 10-4 10000 to 100000
SIL 3 10-4 to 10-3 1000 to 10000
SIL 2 10-3 to 10-2 100 to 1000
SIL 1 10-2 to 10-1 10 to 100
…. For a Safety Instrument Function (SIF) for a SIS
Sensor System Controller Actuator System
VDU and DCU Feed Applications
VDU typical applications
Vacuum distillation
• 4” 300# RF SCH 120
• Flow: 0 –140 m3/h DCU typical applications
• Pressure: 17-20 barg Crude distillation
• Temp: 345°C-380°C • 3” 600# RF SCH XXS
• Flow: 0 –70 m3/h
• Pressure: 30-50 barg
• Temp: 325°C-360°C
Flare Gas measurement
34
Why Measure Flare Gas Flow?
STEAM CONTROL
ENVIRONMENTAL
–Steam Injection
>Mandatory Reporting
•Complete burning
>Avoidance of Penalties •Smokeless operation
– NSPS, EPA, MACT, EU ETS, TCEQ, –Steam Consumption
SCAQMD, Kyoto, BOEMRE, More… •Expensive
•Flow rate controlled
•Molecular weight
–proportion steam
RECOVERY COMPRESSION
ACCOUNTABILITY Waste Gas
•Flare Gas as fuel Furnace
>Flare Base Load
Process Unit
–Typically unknown
>Mass Balance
–Complete balance
LEAK DETECTION
–Drive flaring
reduction –Molecular Weight
CRUDE
FLARE 1 2
•Identification of source
–Leaky Valves
PRODUCT A PRODUCT B PRODUCT C • Potentially 1000’s in 3 4
plant
Flare Gas: Why Measure Ultrasonically?
Conventional technologies all have problems with one or more of
these characteristics of flare gas operation, resulting in inaccuracy,
poor reliability and high cost of ownership.
•FLARE GAS ULTRASONIC METER CAPABILITIES
Variable Flow Rates
Low flow = normal flare The required turn-down ratio and low-end
Moderate flow = inadvertent flare sensitivity exceeds conventional flow
High flow = emergency flare measurement technologies
Variable Composition
Range of hydrocarbons Very wide range of flow rates
H2 to C6 + (typical) Volume flow independent of composition
Corrosive Environment
H2S, HF etc. Materials Compatibility (Ti, Monel,
Liquid dropout Hastelloy)
Low Pressure
No pressure drop
Atmospheric (slightly negative to
slightly positive) No maintenance
Wide Temperature Range
From –190C to 280C overall Wide process temperature range
On-site verification
GE Measurement Flow Solutions in
& Control Power Generation
Applications
Typical Applications for ANY PLANT
Balance of Plant (BoP)
Water, steam (and fuel)
for balance of plant
operations are
continually being heated,
cooled or condensed.
These processes require
flow to be monitored
Compressed Air Cooling Water Stack Gas
Compressed air is used Outside the close loop Flow gas in the stack
for cooling components, of the plant there's a is monitored for
actuating valves, constant water feed tracking emissions to
purging enclosures and to ensure cooling comply with
pressure testing. efficiency. Flow environmental
Air flow can be needs to be requirements among
monitored for process measured. other things
control
Key Applications in Power Plants
Each and every application where our technologies can
provide benefits:
> Low cost of ownership vs. traditional technologies (orifice plates)
> High rangeability (typica l ly 150:1 and even larger for stacks)
> No or minimal pressure drop
> Drift free
> Ability to cope with the harshest conditions
Balance of Plant - BoP
Monitor all the flow medium of the power
production cycle to
calculate the plant efficiency and its
performances relative to
energy production
Example #1: Coal Fired Boilers
Turbine / BOP
Boiler Compressed Air Emissions
Water, demineralized
water, condensate and Air flow Stack Gas flow for
Flow of boiler feed water
steam flow monitoring US clamp on and emissions
US wetted vortex monitoring systems
US wetted and clamp
on (cooling water) and
Vortex
Proposed Solution using BWT for Steam Metering
When the following points can become a challenge for
traditional meters, Ultrasonics technology is the perfect fit
• No obstruction or pressure drop for better efficiency
• No calibration or maintenance required for maintenance cost
reduction
• High Turn-down ratio for changing flowing conditions
• Transducers are removable under flowing conditions for safety
operations
• Work for saturated and superheated steam
Example #2 : Combined Cycle Flow Measurements
Example #3: Hydro Electric Power Plant
Typical Set Up
• Measuring water flow up to 18' («5,5m) diameter penstock!!
• Typical Flow rates of about 4m/s but we tested in France up
to 24m/s!!
Measure flow to validate turbine efficiency
Flow was not previously measured Panametrics
ultrasonic
flowmeter with
clamp on
transducers
Multiphase Meters at
Well Heads
46
Ultrasonic multiphase flowmeter
OUR FOCUS: Oil production
© 2014 General Electric Company 47
It’s time for a solution to measure oil flow
and water cut for new and mature
topside oil field production.
© 2014 General Electric Company 48
Safire* 2.0
The vision: increasing oil production for industry
TODAY TOMORROW
Periodic data collection process Real-time data collection
process with M&C sensors
MONTHLY HOURLY
MEASUREMENT MEASUREMENT
Oil | Water | Gas Oil | Water | Gas
Potential 3%+ production
More frequent reliable data Better decisions
improvement
© 2014 General Electric Company 50
Production Optimization Vision
Integrated Smart & Big data
sensing & automated analytics &
automation workflows optimization
Pump off Safire*
controller Meter
Zenith
Empowered decision making
Maximize existing hardware Analyze & optimize data to
with scaled automated
& capabilities increase production efficiency
expertise
© 2014 General Electric Company 51
The topside Safire* meter today
2-PHASE TARGET COST- RELIABLE & REAL-TIME NON-
(OIL/WATER) LOWER- EFFECTIVE REPEATABLE MEASUREMEN INTRUSIVE
YIELDING TS
WELLS
FEATURES BENEFITS
• Compact economical design
The Safire* meter helps operators to make
• Water (WLR) and oil (OLR) better decisions to reach their goals of:
measurement
• Optimizing oil production and recovery
• Non-intrusive flow measurement
• Reducing the cost and complexity of
• Real-time measurement traditional gauging facilities, and
• Available in 2- and 3-inch versions • Decreasing safety risks
• Dual-channel redundancy
© 2014 General Electric Company 52
Empowering Customers
The Safire* meter helps operators to make better decisions to reach their goals of:
Optimizing oil production Reducing costs & Decreasing safety risks
complexity
...by...
• Enabling accelerated oil • Eliminating the need to • Reducing the amount and
production install traditional size of equipment in the field
- Well level optimization measurement systems to maintain
- Identify underperforming (test separators, AWTs) • Minimizing the occurrence of
wells field fabrication
• Removing the need to
• Enabling increased • Reducing man-hours in the
maintain traditional
reservoir recovery field
measurement system
- Understand well-to- well
interaction (valves, manifolds)
- Optimize injection points • Decreasing the need for
and locations well testing services
- Enhance reservoir &
drilling models
© 2014 General Electric Company 53
Safire Components
Meter
Electronics
Shroud,
Spool, &
Transducers
• Orientation must be vertical with flow going up
• Shroud (and underlying transducers) must be
oriented perpendicular to the blind-T plane
• Requires a wetted RTD
Safire groups at
© 2014 General Electric Company gauge station 55
Performance
Key Specifications
• Crude oil <20% Gas Volume Fraction
Fluid Type • 0-100% Water cut (WLR)
• Water rate (absolute): 1-4%
Accuracy • Oil rate (relative): 5-15%
• Liquid rate (relative): 1-5%
API Range • 13 to 45
Process/Fluid
• 38 - 165 C (100 - 330 F)
Temperature
Flow Range • 400 to 5000 BPD
• 2-inch (50 mm), schedule 80
Pipe Sizes
• 3-inch (75 mm), schedule 80
Sweet Spot: Heavy oil, high water cut
© 2014 General Electric Company
56
Testing
Flow Loops
• GE Billerica (laboratory)
• GE Bangalore (full MPFM)
• Chevron (full MPFM)
In field
• 250+ meters in the field
• Portable Trailers
• Temporary well tests
• Separation for reference
meters
• 2 Safire meters - inlet and
outlet
• Gauge stations
• Well heads
57
© 2014 General Electric Company