Gas Detection Control Panel
Analog and digital controller
4 or 8 lines /
16 to 32 detectors max
Highly versatile controller
le
er
Cost savings
on wiring installation
New • New
e w• •N
•N ew
w
e
•N
•N
ew
The next
w
New • Ne
• Ne
generation
w • New •
of controllers
ew •
•N
ew N
ew
N
ew
•N •N
ew • New • Ne w
Certifications
Controller presentation
The MX 43 is an analog and digital controller designed for the continuous measurement and control of
the gases present in the atmosphere and for 4-20 mA or digital contact signal.
Large graphic display
Front panel
Smart keys make LEDs allow
embedded menus a quick
simple to use and basic
overview of the
installation.
MX 43 manages both digital lines and analog channels, The MX 43 digital technology allows up to 32 detectors to
and covers all needs for a wide variety of applications. be distributed on 8 lines for increased cost savings.
1 Internal battery
2 Strobe and horn
3 Power supply
1
4 6 on-board relays
5 Removable terminals
4
3
5
Graphic display
Normal Mode In 4-channel display
0-100% LEL methane 2 Compressor 1 Turbine 1
Gas compressor
1 L02M01 100 100
7%LEL 21%LEL
7
100 %LEL CH4 CH4
CH4
5 3
0 0
Compressor 2 Turbine 2
50
4 8h avg 100 100
30
15
6 Detector OK
1%LEL
CH4 7%LEL
CH4
At least 1 line is OFF 7
0 0 0 1
Previous Next See 4 previous Next See 16
Menu Curve Menu
detector detector detectors page page detectors
1 Measurement range, gas and detector tag 1 Up to 16 detectors can be displayed simultaneously
2 Detector address
3 Current value with unit and detected gas
4 Averaged value on the last 8 hours
5 Bar graph with alarm thresholds
6 Detector status (OK, OFF, fault)
7 MX 43 status information
Calibration Curve Data-logging
Simplified procedure that enables time savings (i.e. non-intrusive and The MX 43 can store up to 512 alarm events, 512 fault events and
one-man calibration). 512 system events.
0-100% LEL methane
Gas compressor OLCT100 L02M01 Gas alarms 4 64/64
50 Gas compressor AL1 ON 01 13 10 [Link]
Detector %LEL
3
[Link] Gas compressor AL2 ON 01 13 10 [Link]
Zoom
3
Gas compressor AL1 OFF 01 13 10 [Link]
1
Gas compressor AL2 OFF 01 13 10 [Link]
5 Zero
2 1 2
Span
0
End
Gas: 50%LEL 4 07/30/10
previous Next Last
Zoom - Zoom + Delete ESC
page page page
1 Calibration curve 1 Detector tag
2 Cursors for span settings 2 Event
3 Measured value 3 Date and time of events appearance or clearance
4 Calibration gas value 4 Page number (up to 64 pages)
5 Detector selection, zeroing and spanning
Alarm mode
Reverse video in alarm conditions for immediate
0-100% LEL methane
L02M01
identification of the concerned detector.
Gas compressor
40
100 %LEL 1 Current value with unit and detected gas
CH4
88 2 Averaged value on the last 8 hours
1 3 Detector status (OK, OFF, fault)
50
2 8h:22 avg 4 MX 43 status information
30 3 Detector OK 5 Detector in alarm 1
5
4 Normal
AL1
0
Previous Next See 4
Menu Curve
detector detector detectors
GAS DETECTION CONTROL PANEL
Modules
Different modules can be connected to the controller:
4 or 8-relay module 16-logic-input module
4 or 8-programmable- A
Addressable module
relay module can be of 16 logic input for
o
located closer to the rrecovery of digital
actuators for cost information such as
in
savings. fire or intrusion alarms,
emergency stop, limit
e
sswitch activation, etc.
8-analog-input
8 analog input module 4-analog-output module
T
This module enables Addressable 4- analog-
sstandard analog output module which
ttransmitters (gas or flame delivers 4 analog 4-20mA
ddetectors for instance) to signal outputs (detector
bbe connected on a digital output copy, min, max,
lline for cost savings. average of a group of
detectors) for connection
to a datalogger, a PLC,
a Building Management
System (BMS), etc.
Configuration example
MX43 External
Configuration PC power supply
2 logic
with COM43 application inputs
USB
Digital detectors
4-relay module
8-relay module 16-logic-input
module
Analog
detectors
8-analog-inputs
module 4-analog-output module Analog recorders
Analog signal
Digital signal
FEATURES
Model MX 43 gas detection control panel
Dimensions (wall-mounted version) 370 x 299 x 109 mm (14.6 x 11.8 x 4.3 inches)
Dimensions (rack) 19", 4U ; 482.8 x 177 x 192.5 mm (19.1 x 7 x 7.6 inches)
Ingress protection IP55 (wall-mounted), IP31 (rack)
Cable entries (wall-mounted 12 M16 cable glands, 4 to 8 mm² (8 to 11 AWG) outer diameter cable
version) 6 M20 cable glands, 6 to 12 mm² (7 to 9 AWG) outer diameter cable
Display LCD back-lit display + smart keys
Display in video inverse in case of fault
Customizable by user (display 1 to 16 channels simultaneously, fixed or scrolling, on events...)
Bar graph with alarm threshold
Visual indicators 7 LEDs per line
1 LED fault indicator
1 LED fault indicator
Buttons 5 smart keys
1 audible alarm accept/reset button
Operating use
Operating temperature -20°C to +50°C
Storage temperature -20°C to +50°C
Humidity 5 to 95% RH
Power 100-240 Vac 50-60 Hz or 21-28 Vdc, 112 W max
Battery Embedded back up power supply in option (0.6 Ah)
Consumption 500 mA min (without module)
Measurement lines
Digital lines 8 maximum
RS-485 communication, proprietary protocol, 9600 Baud
2 twisted shielded-pair cable
Analog channels 8 maximum
0-23 mA analog signal input (4 to 20 mA reserved for measurement) 120 Ohm load resistance
2 or 3-core shielded cable
Voltage (typical) 21 to 28Vdc
Maximum current output per line 500 mA
Maximum current output in total 2.4 A permanent (3.2 A intermittently)
Alarms
Per channel 5 alarm levels (A1, A2, A3, Overscale, Underscale) + Fault
Non-ambiguity reading option for combustible gases monitoring
Programmable thresholds On instantenous ou averaged values, rising or falling alarms, manual or automatic
acknowledgement
On-board relays 5 fully programmable alarm relays
1 fault relay (non-configurable)
Dry contact relay
DPCO relays with contact rating of 250 Vca 2 A (inductive)
Digital outputs RS-485 Modbus RTU serial link
Approvals
EMC According to EN50270
ATEX EN50271 and metrological performances according to EN60079-29-1
Low Voltage Directive According to EN61010
CSA Pending
Our fixed detector range
OLCT 10
OLCT 10N
OLCT 80
OLCT 100
OLCT 60 OLCT 60 / OLCT IR OLCT IR Flame detector
OUR MISSION
Preserving human life, above and below the earth.
Delivering highest quality, best customer service…
Every transaction, every time
Ref. MX43_Lit_EN_v3
REV 0811
For pricing, or any further, information please contact Omni Instruments Ltd
Tel: +44 (0)845 9000 601 or visit our website at [Link]