0% found this document useful (0 votes)
70 views4 pages

Wall No. 5 Reinforcement Details

This document provides information on the reinforcement design of wall panel no. 233. It includes details on the wall geometry and materials, reinforcement sizes and locations, and results of structural calculations. The wall is 4.2 meters high and 0.4 meters thick. It requires 10.47 cm2/m of reinforcement in both the bottom and top layers to resist tension forces of 4 kN/m. The provided reinforcement exceeds these requirements. Reinforcement consists of 1.2 cm diameter bars with 3 cm cover on both faces.

Uploaded by

Ali Al-Basha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views4 pages

Wall No. 5 Reinforcement Details

This document provides information on the reinforcement design of wall panel no. 233. It includes details on the wall geometry and materials, reinforcement sizes and locations, and results of structural calculations. The wall is 4.2 meters high and 0.4 meters thick. It requires 10.47 cm2/m of reinforcement in both the bottom and top layers to resist tension forces of 4 kN/m. The provided reinforcement exceeds these requirements. Reinforcement consists of 1.2 cm diameter bars with 3 cm cover on both faces.

Uploaded by

Ali Al-Basha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd

1. Wall: Wall No.5 (4.2)m - Panel no.

233
1.1. Reinforcement:

 Type : RC wall
 Main reinforcement direction : 0°
Main reinforcement grade : B500B; Characteristic strength = 500.00 MPa
Horizontal branch of the stress-strain diagram
 Ductility class :B
 Bar diameters bottom d1 = 1.2 (cm) d2 =
1.2 (cm)
top d1 = 1.2 (cm) d2 = 1.2 (cm)
 Cover bottom c1 = 3.0 (cm)
top c2 = 3.0 (cm)
 Cover deviations Cdev = 1.0(cm), Cdur = 0.0(cm)

1.2. Concrete

Class : C30/37; Characteristic strength = 30.00 MPa


Rectangular stress distribution [3.1.7(3)]
 Density : 2501.36 (kG/m3)
 Concrete creep coefficient: 1.32
 Cement class :N

1.3. Hypothesis

 Calculations according to
: EN 1992-1-1:2004/A1:2014
 Method of reinforcement area
calculations : analytical
 Allowable cracking width
- upper layer : 0.40 (mm)
- lower layer : 0.40 (mm)
 Verification of punching : no
 Exposure
- upper layer : X0
- lower layer : X0
 Calculation type :
compression/tension
 Structure class : S1

1.4. Wall geometry

Thickness 0.40 (m)

Contour:
edge beginning end length
x1 y1 x2 y2 (m)
1 0.00 -4.20 2.41 -4.20 2.41
2 2.41 -4.20 2.41 0.00 4.20
3 2.41 0.00 0.00 0.00 2.41
4 0.00 0.00 0.00 -4.20 4.20

Support:
n° Name dimensions coordinates edge
(m) x y
0 linear 0.15 / 1.42 1.43 -2.10 —
0 linear 0.36 -2.36 —
* - head present

1.5. Calculation results:

1.5.1. Maximum forces + reinforcement

Ax(+) Ax(-) Ay(+) Ay(-)

Provided reinforcement (cm2/m):


0.00 0.00 10.47 10.47
Modified required reinforcement (cm2/m):
0.00 0.00 4.00 4.00
Original required reinforcement (cm2/m):
0.00 0.00 4.00 4.00
Coordinates (m):
-26.82;-4.20 -26.82;-4.20 2.14;-2.10 2.14;-
2.10

1.5.2. Maximum forces + reinforcement

Ax(+) Ax(-) Ay(+) Ay(-)

Symbol: required area/provided area


Ax(+) (cm2/m) 0.00/0.00 0.00/0.00 0.00/10.47
0.00/10.47
Ax(-) (cm2/m) 0.00/0.00 0.00/0.00 0.00/10.47
0.00/10.47
Ay(+) (cm2/m) 4.00/0.00 4.00/0.00 4.00/10.47
4.00/10.47
Ay(-) (cm2/m) 4.00/0.00 4.00/0.00 4.00/10.47
4.00/10.47

SLS
Mxx (kN*m/m) 0.00 0.00 -0.29 -0.29
Myy (kN*m/m) 0.00 0.00 -1.54 -1.54
Mxy (kN*m/m) 0.00 0.00 -0.02 -0.02

Nxx (kN/m) 0.00 0.00 1.35 1.35


Nyy (kN/m) 0.00 0.00 -58.29 -58.29
Nxy (kN/m) 0.00 0.00 -8.48 -8.48

ULS
Mxx (kN*m/m) 0.00 0.00 -0.33 -0.33
Myy (kN*m/m) 0.00 0.00 -2.01 -2.01
Mxy (kN*m/m) 0.00 0.00 0.02 0.02
Nxx (kN/m) 0.00 0.00 2.03 2.03
Nyy (kN/m) 0.00 0.00 -73.31 -73.31
Nxy (kN/m) 0.00 0.00 -11.25 -11.25

Coordinates (m) -26.82;-4.20 -26.82;-4.20 2.14;-2.10 2.14;-


2.10
Coordinates* (m) 0.00;0.00;0.00 0.00;0.00;0.00 24.85;28.95;2.10
24.85;28.95;2.10
* - Coordinates in the structure global coordinate system

3. Results - detailing
List of solutions:
Reinforcement: bars
Solution no. Reinforcement range Total weight
Diameter / Weight (kG)
1 - 332.95

Results for the solution no. 1


Reinforcement zones

Bottom reinforcement
Name coordinates Provided reinforcement At
Ar
x1 y1 x2 y2 f (mm) / (cm) (cm2/m)
(cm2/m)
1/1- Ax Main 2.41 -4.20 0.00 -0.00 20.0 / 30.0 0.00 <
10.47
1/2- Ay Perpendicular 2.41 -4.20 0.00 -0.00 20.0 / 30.0 4.00 <
10.47

Top reinforcement
Name coordinates Provided reinforcement At
Ar
x1 y1 x2 y2 f (mm) / (cm) (cm2/m)
(cm2/m)
1/1+ Ax Main 2.41 -4.20 0.00 -0.00 20.0 / 30.0 0.00 <
10.47
1/2+ Ay Perpendicular 2.41 -4.20 0.00 -0.00 20.0 / 30.0 4.00 <
10.47

4. Material survey
 Concrete volume = 4.05 (m3)
 Formwork = 10.12 (m2)
 Slab circumference = 13.22 (m)
 Area of openings = 0.00 (m2)
 Steel B500B
 Total weight = 325.74 (kG)
 Density = 80.45 (kG/m3)
 Average diameter = 20.0 (mm)
 Survey according to diameters:

Diameter Length Number of identical elements:


(m)
20 2.35 28
20 4.14 16