Proračun gubitaka topline peći

The document discusses calculating heat losses through the walls of a previous roller furnace used for normalizing rail tracks. It provides the dimensions and materials of the furnace walls. It then calculates: 1) The predicted and average temperatures at different wall depths. 2) The heat transfer coefficient and heat flux through the walls. 3) The internal and external surface areas of the furnace. 4) The total heat loss through the walls during operation and due to accumulation in periodic furnace operation.

Uploaded by

Zlatko Somić
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views5 pages

Proračun gubitaka topline peći

The document discusses calculating heat losses through the walls of a previous roller furnace used for normalizing rail tracks. It provides the dimensions and materials of the furnace walls. It then calculates: 1) The predicted and average temperatures at different wall depths. 2) The heat transfer coefficient and heat flux through the walls. 3) The internal and external surface areas of the furnace. 4) The total heat loss through the walls during operation and due to accumulation in periodic furnace operation.

Uploaded by

Zlatko Somić
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

Zadatak:

Potrebno je proračunati gubitke topline kroz zidove prethodne peći s valjcima za normalizacijsko
žarenje tračnica. Peć započinje s radom i tijekom rada temperatura unutarnjih zidova peći je 1100 oC.
Unutarnje dimenzije peći su:

Visina hi=750mm;

Širina bi= 3000mm;

Duljina li=35 000mm.

Peć je konstruirana tako da se zid sastoji od sloja vatrostalnog silikatnog betona debljine 230mm,
drugi sloj izolacijska opeka debljine 130 mm (ρ=450 kg/m3) i treći sloj troskna vuna debljine 40mm.
Plašt peći je od čeličnog lima debljine 15mm. Potrebno je odrediti gubitke zbog akumulacije i tijekom
rada kroz zidove peći.

Proračun:

1. Predviđene temperature i temperature dobivene srednjom vrijednosti:

ϑ𝑜𝑖 =1100 oC

ϑ1 =1005oC

ϑ1,2 =910oC

ϑ2 =712oC

ϑ2,3 =514oC

ϑ3 =290oC

ϑ3,4 =66oC

ϑ4 =66oC

ϑ𝑜𝑎 =66oC

Vrijednosti iz tablice 2.9 i 2.8

𝜆1 = 1,66 [W/m*K]

𝜆2 =0,18 [W/m*K]

𝜆3 =0,08 [W/m*K]

𝜆4 =51,1 [W/m*K] (čelik C20)


Horizontalno:

𝛼𝑜1 =9,4 + 0,057 *66=13,16 [W/(m2*K)]

Vertikalno:

𝛼𝑜1 = 7,1+0,057*66 =10,86 [W/(m2*K)]


13,16+10,86
𝛼𝑜1 = =12,01 [W/(m2*K)] srednja vrijednost
2

1
= 0,083
𝛼𝑜1

𝑠1 0,230
= = 0,138
𝜆1 1,66

𝑠2 0,130
= = 0,722
𝜆2 0,18

𝑠3 0,040
= = 0,500
𝜆3 0,08

𝑠4 0,015
= = 0,00029 - može se zanemariti
𝜆4 51,1

𝑠
Σ = 1,360
𝜆

Prema jednadžbi 6,26:


1 1
k= 𝑠 1 = = 0,712 [W/(m2*K)]
+ 1,360+0,044
𝜆 𝛼𝑜1

i prema tome

qw=k(ϑ𝑜𝑖 - ϑ1 ) prema jednadžbi 6,25

qw=0,712 (1100-20)

qw= 769 W/m2

Kontrolno računanje provodi se s jednadžbom 6.29a preinakom postaje


𝑠
ϑ1,2 = ϑ𝑜𝑖 −qw 1 =1100 - 769 *0,138=994 oC
𝜆1

𝑠 𝑠
ϑ2,3 = ϑ𝑜𝑖 - qw( 1 + 2 )=1100 - 769 * (0,138 + 0,722) =439 oC
𝜆1 𝜆2
𝑠
ϑ3,4 = ϑ𝑜𝑎 = ϑ𝑜𝑖 -qw* Σ = 1100 - 769 * 1,360=54oC
𝜆

1. Predviđene temperature i temperature dobivene srednjom vrijednosti:

ϑ𝑜𝑖 =1100 oC

ϑ1 =1047oC

ϑ1,2 =994oC

ϑ2 =716oC

ϑ2,3 =439oC

ϑ3 =246oC

ϑ3,4 =54oC

ϑ4 =54oC

ϑ𝑜𝑎 =54oC

Vrijednosti iz tablice 2.9 i 2.8

𝜆1 = 1, 711[W/m*K]

𝜆2 =0,165 [W/m*K]

𝜆3 =0,08 [W/m*K]

𝜆4 =51,3 [W/m*K]

Horizontalno:

𝛼𝑜1 =9,4 + 0,057 *54= 12,47 [W/(m2*K)]

Vertikalno:

𝛼𝑜1 = 7,1+0,057*54 =10,18 [W/(m2*K)]


12,47+10,18
𝛼𝑜1 = =11,32
2
1
=0,088
𝛼𝑜1

𝑠1 0,230
= =0,134
𝜆1 1,71

𝑠2 0,130
= =0,788
𝜆2 0,165

𝑠3 0,040
= =0,500
𝜆3 0,08

𝑠4 0,015
= =0,00029
𝜆4 51,3

𝑠
Σ =1,42
𝜆

Prema jednadžbi 6,26:


1 1
k= 𝑠 1 = =0,663[W/(m2*K)]
+ 0,23+0,0165
𝜆 𝛼𝑜1

i prema tome

qw=k(ϑ𝑜𝑖 - ϑ1 ) prema jednadžbi 6,25

qw=0,663 (1100-20)

qw= 716,04 W/m2

Kontrolno računanje provodi se s jednadžbom 6.29a preinakom postaje


𝑠
ϑ1,2 = ϑ𝑜𝑖 −qw 1 =1100 –716,04* 0,134=1004oC
𝜆1

𝑠 𝑠
ϑ2,3 = ϑ𝑜𝑖 - qw( 1 + 2 )=1100 - 716,04* (0,134 + 0,788) =439oC
𝜆1 𝜆2

𝑠
ϑ3,4 = ϑ𝑜𝑎 - ϑ𝑜𝑖 -qw* Σ = 1100 –716,04*1,42= 83oC
𝜆

qw= 716,04 W/m2

Unutarnja površina peći

Ai=2(hi*bi+bi*li+li*hi)=2(750*3000+3000*35000+35000*750)

Ai=133, 5m2

Vanjska površina peći


ha=h1+2 (S1+S2+S3+S4) =750+2(400)=1150 mm

ba=bi+2 (S1+S2+S3+S4) =3000+2(400)= 3800 mm

la=li+2 (S1+S2+S3+S4) =35000+2(400)=35800 mm

Aa=2(ha*ba*+ ba* la+la*ha) =2(1,150*3,800+3,800*35 800+35 800*1,150)=

Aa=354,4m2

Prema jednadžbi 6,31


𝐴𝑎+𝐴𝑖 354,4+133,5
qw= = =243,95kW
2 2

Gubitak kroz zidove u povremeno odn. Periodično pogonjenim pećima;

Gubitak zbog akumulacije:

-za višeslojan zid


𝜗0𝑖 +𝜗1,2 𝜗1,2 +𝜗2,3 𝜗2,3+𝜗3,4
Qsp=s1*ρ1*c1( − 𝜗1 )+s2*ρ2*c2( − 𝜗1 )+s3*ρ3*c3( − 𝜗1 )=
2 2 2

1100+1005 1005+439
Qsp=0,230*1850*1,18( − 1052)+0,130*450*0,96( −
2 2
439+83
1052)+0,040*130*0,80( − 1052)=
2

Qsp= 22074,40 [J/m2]

Cjelokupan gubitak kroz zidove:

qw=qol=𝛼𝑜1 (𝜗0𝑎 -ϑ1) =

qw=11,32(83-1052)= -10969