Technical

Specification

Flygt 3102, 50Hz


Table of Contents

Table of Contents
C-pump, Standard Motor......................................................................................................................2
Product description.............................................................................................................................2
Motor rating and performance curves..............................................................................................4

C-pump, Premium Efficiency Motor.....................................................................................................6


Product description.............................................................................................................................6
Motor rating and performance curves..............................................................................................8

D-pump.................................................................................................................................................10
Product description..........................................................................................................................10
Motor rating and performance curves...........................................................................................12

F-pump..................................................................................................................................................15
Product description..........................................................................................................................15
Motor rating and performance curves...........................................................................................17

M-pump.................................................................................................................................................19
Product description..........................................................................................................................19
Motor rating and performance curves...........................................................................................21

N-pump, Standard Motor...................................................................................................................24


Product description..........................................................................................................................24
Motor rating and performance curves...........................................................................................26

N-pump, Premium Efficiency Motor (IE3).........................................................................................30


Product description..........................................................................................................................30
Motor rating and performance curves 3102.800/.810.................................................................32
Motor rating and performance curves 3102.820/.830.................................................................35
Motor rating and performance curves 3102.900/.910.................................................................38

Dimensions and Weight......................................................................................................................42


Drawings, C-pump............................................................................................................................42
Drawings, D-pump............................................................................................................................46
Drawings, F-pump.............................................................................................................................47
Drawings, M-pump...........................................................................................................................48
Drawings, N-pump............................................................................................................................49

Flygt 3102, 50Hz Technical Specification 1


C-pump, Standard Motor

C-pump, Standard Motor


Product description
Usage
Submersible pump for pumping clean water, surface water and waste water containing
solids or long-fibred material.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Standard 3102.181 3102.090 MT — Medium head P, S, T, Z

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Liquid temperature, warm water version Maximum 70°C, (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Rated output variation ±10%

2 Flygt 3102, 50Hz Technical Specification


C-pump, Standard Motor

Feature Description

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%
Voltage imbalance Maximum 2%
between phases

Insulation class H (180°C, 356°F)

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5 mm2


cable 4G2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5 mm2


cable 7G2.5+2×1.5 mm2

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing, Cast iron, gray 35B GJL-250
alternative 1
Pump housing, Cast iron, gray ASTM A 48 NO 30B GJL-200
alternative 2
Impeller Cast iron, gray 35B GJL-250
Wear ring, alternative 1 Rubber material, NBR
Wear ring, alternative 2 Bronze C924 CC491K, CC492K
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH
O-rings, alternative 2 Fluorinated rubber (FPM)
70° IRH
Oil, part no 901752 Medical white oil of paraffin
type. Fulfills FDA 172.878
(a)

Table 1: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide
2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide

Flygt 3102, 50Hz Technical Specification 3


C-pump, Standard Motor

Alternative Inner seal Outer seal


3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Warm liquid version (non-explosion proof versions)
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


Star-delta starting current is 1/3 of Direct on-line starting current.

4 Flygt 3102, 50Hz Technical Specification


C-pump, Standard Motor

MT

WS005029A

Table 2: 400 V, 50 Hz, 3–phase

Rated Rated Curve/ Revolution Rated Starting Power Impeller Installation


power kW power hp Impeller s per current, A current, A factor, cos thoughlet,
No minute, φ mm
rpm
2,4 3,2 432 1455 5,1 33 0,8 76 T,Z
2,4 3,2 433 1455 5,1 33 0,8 76 T,Z
2,4 3,2 434 1455 5,1 33 0,8 76 T,Z
2,4 3,2 435 1455 5,1 33 0,8 76 T,Z
3,1 4,2 430 1440 6,3 33 0,85 76 P,S
3,1 4,2 432 1440 6,3 33 0,85 76 P,S
3,1 4,2 433 1440 6,3 33 0,85 76 P,S
3,1 4,2 434 1440 6,3 33 0,85 76 P,S
3,1 4,2 435 1440 6,3 33 0,85 76 P,S

Flygt 3102, 50Hz Technical Specification 5


C-pump, Premium Efficiency Motor

C-pump, Premium Efficiency Motor


Product description
Usage
Submersible pump for pumping clean water, surface water and waste water containing
solids or long-fibred material.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Standard 3102.800 3102.810 • MT — Medium P, S, T, Z
head

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Liquid temperature, warm water version Maximum 70°C, (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Line started permanent magnet motor (LSPM)

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Rated output variation ±10%

6 Flygt 3102, 50Hz Technical Specification


C-pump, Premium Efficiency Motor

Feature Description

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%
Voltage imbalance Maximum 2%
between phases

Insulation class H (180°C, 356°F)

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5+2×1.5 mm2


cable S3×2.5 mm2
S6×2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5+2×1.5 mm2


cable

Screened SUBCAB® heavy-duty S3×2.5+3×2.5/3+4×1.5 mm2


submersible cable

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing, Cast iron, gray 35B GJL-250
alternative 1
Pump housing, Cast iron, gray ASTM A 48 NO 30B GJL-200
alternative 2
Impeller Cast iron, gray 35B GJL-250
Wear ring, alternative 1 Rubber material, NBR – –
Wear ring, alternative 2 Bronze C924 CC491K, CC492K
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM) – –
70° IRH
Oil, part no 901752 Medical white oil of paraffin – –
type. Fulfills FDA 172.878
(a)

Table 3: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide

Flygt 3102, 50Hz Technical Specification 7


C-pump, Premium Efficiency Motor

Alternative Inner seal Outer seal


2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide
3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


Star-delta starting current is 1/3 of Direct on-line starting current.

8 Flygt 3102, 50Hz Technical Specification


C-pump, Premium Efficiency Motor

MT
P2 [kW]

2.5 435
432
2.0
434
1.5 433

1.0
0.5
0.0
H [m]

MT
12

10

432
2
434 433
435

0
0 5 10 15 20 25 30 35 40
Q [l/s]
WS005230A

Table 4: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 432 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 433 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 434 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 435 1500 6.3 40 .88 P,S,T,Z

Flygt 3102, 50Hz Technical Specification 9


D-pump

D-pump
Product description
Usage
Submersible pump for pumping liquids containing solids, abrasive media or low volumes
at high heads.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Standard 3102.181 3102.090 • MT — Medium P, T, Z
head
• HT — High head

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Liquid temperature, warm water version Maximum 70°C, (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Rated output variation ±10%

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%

10 Flygt 3102, 50Hz Technical Specification


D-pump

Feature Description

Voltage imbalance Maximum 2%


between phases

Insulation class H (180°C, 356°F)

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5 mm2


cable 4G2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5 mm2


cable 7G2.5+2×1.5 mm2

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, gray 35B GJL-250
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM) – –
70° IRH
Oil, part no 901752 Medical white oil of paraffin – –
type. Fulfills FDA 172.878
(a)

Table 5: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide
2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide
3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

Flygt 3102, 50Hz Technical Specification 11


D-pump

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Warm liquid version (non-explosion proof versions)
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


Star-delta starting current is 1/3 of Direct on-line starting current.

12 Flygt 3102, 50Hz Technical Specification


D-pump

MT

WS005023A

Table 6: 400 V, 50 Hz, 3–phase

Rated Rated Curve/ Revolution Rated Starting Power Impeller Installation


power kW power hp Impeller s per current, A current, A factor, cos throughlet,
No minute, φ mm
rpm
3,1 4,2 470 1440 6,3 33 0,85 – P
3,1 4,2 471 1440 6,3 33 0,85 100 P
3,1 4,2 472 1440 6,3 33 0,85 100 P

Flygt 3102, 50Hz Technical Specification 13


D-pump

HT

WS005032A

Table 7: 400 V, 50 Hz, 3–phase

Rated Rated Curve/ Revolution Rated Starting Power Impeller Installation


power kW power hp Impeller s per current, A current, A factor, cos throughlet,
No minute, φ mm
rpm
4,2 5,6 276 2850 8,2 52 0,94 52 P
4,2 5,6 278 2850 8,2 52 0,94 52 P

14 Flygt 3102, 50Hz Technical Specification


F-pump

F-pump
Product description
Usage
Submersible pump for pumping liquid manure, or heavily contaminated sewage and
sludge. The impeller is S-shaped and fitted with a cutting device.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Standard 3102.181 3102.090 LT — Low head P, S

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Liquid temperature, warm water version Maximum 70°C, (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Rated output variation ±10%

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%
Voltage imbalance Maximum 2%
between phases

Insulation class H (180°C, 356°F)

Flygt 3102, 50Hz Technical Specification 15


F-pump

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5 mm2


cable 4G2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5 mm2


cable 7G2.5+2×1.5 mm2

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, nodular – GJS-400-18-LT
Suction cover Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM) – –
70° IRH
Oil, part no 901752 Medical white oil of paraffin – –
type. Fulfills FDA 172.878
(a)

Table 8: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide
2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide
3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

16 Flygt 3102, 50Hz Technical Specification


F-pump

Options
• Warm liquid version (non-explosion proof versions)
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


Star-delta starting current is 1/3 of Direct on-line starting current.
LT
P 2 [kW]

3.0
490
2.5
491
2.0 493
492

1.5 494

H [m]

LT
12

10

2
490
492 491
494 493
0
0 5 10 15 20 25 30
Q [l/s]
WS005033A

Table 9: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3,1 4,2 490 1440 6,3 33 0,85 P,S
3,1 4,2 491 1440 6,3 33 0,85 P,S
3,1 4,2 492 1440 6,3 33 0,85 P,S
3,1 4,2 493 1440 6,3 33 0,85 P,S

Flygt 3102, 50Hz Technical Specification 17


F-pump

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3,1 4,2 494 1440 6,3 33 0,85 P,S

18 Flygt 3102, 50Hz Technical Specification


M-pump

M-pump
Product description
Usage
Submersible pump for pumping waste water containing solids that need to be macerated.
The impeller is equipped with a grinder device.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Standard 3102.170 3102.890 • LT — Low head F, H, P
• HT — High head

The pump can be used in the following installations:


F Free standing semi permanent, wet well arrangement where the pump is placed on a
firm surface.
H Semi permanent, wet well quick connection suspended arrangement, incorporating
integral non-return valve.
P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Rated output variation ±10%

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%
Voltage imbalance Maximum 2%
between phases

Flygt 3102, 50Hz Technical Specification 19


M-pump

Feature Description

Insulation class H (180°C, 356°F)

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5 mm2


cable 4G2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5 mm2


cable 7G2.5+2×1.5 mm2

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, gray 30B GJL-200
Cutter wheel Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Cutter plate Stainless steel – –
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings Nitrile rubber (NBR) 70° IRH – –
Oil, part no 901752 Medical white oil of paraffin – –
type. Fulfills FDA 172.878
(a)

Table 10: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide
2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide
3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

20 Flygt 3102, 50Hz Technical Specification


M-pump

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


Star-delta starting current is 1/3 of Direct on-line starting current.

Flygt 3102, 50Hz Technical Specification 21


M-pump

LT

WS005036A

Table 11: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
4,4 5,9 210 2885 8,7 72 0,89 F,H,P

22 Flygt 3102, 50Hz Technical Specification


M-pump

HT
P 2 [kW]

5.0
4.5
261
4.0
3.5
3.0

H [m]

HT
40

35

30

25

20

15

10
261
5

0
0 1 2 3 4 5 6
Q [l/s]
WS005037A

Table 12: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
4,4 5,9 261 2885 8,7 72 0,89 F,H,P

Flygt 3102, 50Hz Technical Specification 23


N-pump, Standard Motor

N-pump, Standard Motor


Product description
Usage
The submersible pump is designed for pumping clean water, surface water, and
wastewater containing solids or long-fibred material.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Adaptive 3102.160 3102.190 • LT — Low head P, S, T, Z
Standard 3102.181 3102.090 • MT — Medium L, P, S, T, Z
head
Hard-Iron ™ 3102.185 3102.095 • SH — Super head P, S, T, Z

The pump can be used in the following installations:


L Semi permanent, wet well column pipe arrangement where the well is divided into a
suction part and a discharge part. Pump end equipped with guide vanes.
P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Liquid temperature, warm water version Maximum 70°C, (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

24 Flygt 3102, 50Hz Technical Specification


N-pump, Standard Motor

Feature Description

Code compliance IEC 60034-1

Rated output variation ±10%

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%
Voltage imbalance Maximum 2%
between phases

Insulation class H (180°C, 356°F)

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5 mm2


cable 4G2.5+2×1.5 mm2
Screened SUBCAB® heavy-duty S3×2.5 mm2
submersible cable
S6×2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5+2×1.5 mm2


cable S3×2.5+3×2.5/3+4×1.5 mm2

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing, Cast iron, gray 35B GJL-250
alternative 1
Pump housing, Cast iron, gray ASTM A 48 NO 30B GJL-200
alternative 2
Impeller Alt 1 Cast iron, gray 35B GJL-250
Impeller Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Insert ring Alt 1 Cast iron, gray 35B GJL-250
Insert ring Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM) – –
70° IRH

Flygt 3102, 50Hz Technical Specification 25


N-pump, Standard Motor

Denomination Material ASTM EN


Oil, part no 901752 Medical white oil of paraffin – –
type. Fulfills FDA 172.878
(a)

Table 13: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide
2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide
3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Warm liquid version (non-explosion proof versions)
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


Star-delta starting current is 1/3 of Direct on-line starting current.

26 Flygt 3102, 50Hz Technical Specification


N-pump, Standard Motor

LT
P2 [kW]

3.5
420*
3.0 420**

2.5 421*

421**
2.0 423*
423**
1.5

H [m]

LT
10

4
420*
421*
2 420**
423* 421**
423**

0
0 10 20 30 40 50 60 70
Q [l/s]
WS005038A

* Pumphousing with outlet 100 mm


** Pumphousing with outlet 150 mm
Table 14: 400 V, 50 Hz, 3–phase

Rated Rated Curve/ Revolutions per Rated Starting Power Installation


power kW power hp Impeller No minute, rpm current, A current, A factor, cos φ
2,4 3,2 421 1460 5,7 40 0,71 T,Z
2,4 3,2 423 1460 5,7 40 0,71 T,Z
3,1 4,2 420 1450 6,8 40 0,78 P,S
3,1 4,2 421 1450 6,8 40 0,78 P,S
3,1 4,2 423 1450 6,8 40 0,78 P,S

Flygt 3102, 50Hz Technical Specification 27


N-pump, Standard Motor

MT
P2 [kW]

460
3
461
462
2 463
464

0
H [m]

MT
14

12

10

8 460

2 461
462
464 463

0
0 10 20 30 40 50
Q [l/s]
WS005039A

Table 15: 400 V, 50 Hz, 3–phase

Rated Rated Curve/ Revolutions per Rated Starting Power Installation


power kW power hp Impeller No minute, rpm current, A current, A factor, cos φ
2,4 3,2 462 1460 5,7 40 0,71 T,Z
2,4 3,2 463 1460 5,7 40 0,71 T,Z
2,4 3,2 464 1460 5,7 40 0,71 T,Z
3,1 4,2 460 1450 6,8 40 0,78 P,S
3,1 4,2 461 1450 6,8 40 0,78 P,S
3,1 4,2 462 1450 6,8 40 0,78 P,S
3,1 4,2 463 1450 6,8 40 0,78 P,S
3,1 4,2 464 1450 6,8 40 0,78 P,S

28 Flygt 3102, 50Hz Technical Specification


N-pump, Standard Motor

SH
P2 [kW]

4
255
3

2 256

H [m]

SH
30

25

20

15

10

5
256
255
0
0 5 10 15 20 25 30
Q [l/s]
WS005040A

Table 16: 400 V, 50 Hz, 3–phase

Rated Rated Curve/ Revolutions per Rated Starting Power Installation


power kW power hp Impeller No minute, rpm current, A current, A factor, cos φ
4,2 5,6 255 2850 8,2 52 0,94 P,S
4,2 5,6 256 2850 8,2 52 0,94 T,Z

Flygt 3102, 50Hz Technical Specification 29


N-pump, Premium Efficiency Motor (IE3)

N-pump, Premium Efficiency Motor


(IE3)
Product description
Usage
The submersible pump is designed for pumping clean water, surface water, and
wastewater containing solids or long-fibred material.
Denomination
Type Non explosion proof Explosion proof Pressure class Installation types
version version
Standard 3102.800 3102.810 • LT — Low head P, S, T, Z
Hard-Iron ™ 3102.820 3102.820 • MT — Medium
head
Adaptive 3102.900 3102.910 • SH — Super head

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application Limits
Feature Description

Liquid temperature Maximum 40°C, (104°F)

Liquid temperature, warm water version Maximum 70°C, (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data
Feature Description

Motor type Line started permanent magnet motor (LSPM)

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line


• Star-delta
Number of starts per hour Maximum 30

30 Flygt 3102, 50Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

Feature Description

Code compliance IEC 60034-1

Rated output variation ±10%

Voltage variation • Continuously running: Maximum ±5%


• Intermittent running: Maximum ±10%
Voltage imbalance Maximum 2%
between phases

Insulation class H (180°C, 356°F)

Cables
Application Type Denomination

Direct-on-line start SUBCAB® heavy-duty submersible 4G2.5 mm2


cable 4G2.5+2×1.5 mm2
7G2.5 mm2
7G2.5+2×1.5 mm2

Y/D start SUBCAB® heavy-duty submersible 7G2.5 mm2


cable 7G2.5+2×1.5 mm2

Screened SUBCAB® heavy-duty S3×2.5 mm2


submersible cable S3×2.5+3×2.5/3+4×1.5 mm2
S6×2.5+2×1.5 mm2

Monitoring Equipment
Thermal contacts opening temperature 125° C (257° F)
Materials
Denomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing, Cast iron, gray 35B GJL-250
alternative 1
Pump housing, Cast iron, gray ASTM A 48 NO 30B GJL-200
alternative 2
Impeller Alt 1 Cast iron, gray 35B GJL-250
Impeller Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Insert ring Alt 1 Cast iron, gray 35B GJL-250
Insert ring Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM) – –
70° IRH

Flygt 3102, 50Hz Technical Specification 31


N-pump, Premium Efficiency Motor (IE3)

Denomination Material ASTM EN


Oil, part no 901752 Medical white oil of paraffin – –
type. Fulfills FDA 172.878
(a)

Table 17: Mechanical face seals

Alternative Inner seal Outer seal


1 Aluminum oxide/ Corrosion resistant Aluminum oxide/ Corrosion resistant
cemented carbide cemented carbide
2 Aluminum oxide/ Corrosion resistant Corrosion resistant cemented
cemented carbide carbide/ Corrosion resistant
cemented carbide
3 Corrosion resistant cemented Aluminum oxide/ Corrosion resistant
carbide/ Corrosion resistant cemented carbide
cemented carbide
4 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide

Surface Treatment
Priming Finish

Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Leakage sensor in the stator housing (FLS)
• Leakage sensor in the oil housing (CLS)
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves 3102.800/.810


Star-delta starting current is 1/3 of Direct on-line starting current.

32 Flygt 3102, 50Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

LT
P2 [kW]

3.5
420
3.0

2.5
421

2.0 423

H [m]

LT
12

10

2
420
423 421
0
0 10 20 30 40 50 60 70
Q [l/s]
WS005227A

Table 18: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 420 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 421 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 423 1500 6.3 40 .88 P,S,T,Z

Flygt 3102, 50Hz Technical Specification 33


N-pump, Premium Efficiency Motor (IE3)

MT
P2 [kW]
460

461
3
462
463
2 464

0
H [m]

MT
16

14

12

10
460
460
8

2 461
462
463
464
0
0 10 20 30 40 50
Q [l/s]
WS005228A

Table 19: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 460 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 461 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 462 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 463 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 464 1500 6.3 40 .88 P,S,T,Z

34 Flygt 3102, 50Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

SH
P2 [kW]

4.0
3.5
258
3.0
2.5
256
2.0
1.5

H [m]

SH
30

25

20

15

10

5
256
256 258

0
0 5 10 15 20 25 30
Q [l/s]
WS005229A

Table 20: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
2.8 3.8 256 3000 5.9 64 .77 T,Z
4.5 6 256 3000 8.5 64 .86 P,S
4.5 6 258 3000 8.5 64 .86 P,S

Motor rating and performance curves 3102.820/.830


Star-delta starting current is 1/3 of Direct on-line starting current.

Flygt 3102, 50Hz Technical Specification 35


N-pump, Premium Efficiency Motor (IE3)

LT
P2 [kW]

3.5
420
3.0

2.5
421

2.0
423

H [m]

LT
12

10

2
420
423 421
0
0 10 20 30 40 50 60 70
Q [l/s]
WS005224A

Table 21: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 420 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 421 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 423 1500 6.3 40 .88 P,S,T,Z

36 Flygt 3102, 50Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

MT
P2 [kW]
460

461
3
462
463
2 464
464

0
H [m]

MT
16

14

12

10
460
8

4
461
2 462
463
464
0
0 10 20 30 40 50
Q [l/s]
WS005225A

Table 22: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 460 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 461 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 462 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 463 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 464 1500 6.3 40 .88 P,S,T,Z

Flygt 3102, 50Hz Technical Specification 37


N-pump, Premium Efficiency Motor (IE3)

SH
P2 [kW]

4.0
3.5
258
3.0
2.5
256
2.0
1.5

H [m]

SH
30

25

20

15

10

5
256
258
256
0
0 5 10 15 20 25 30
Q [l/s]
WS005226A

Table 23: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
2.8 3.8 256 3000 5.9 64 .77 T,Z
4.5 6 256 3000 8.5 64 .86 P,S
4.5 6 258 3000 8.5 64 .86 P,S

Motor rating and performance curves 3102.900/.910


Star-delta starting current is 1/3 of Direct on-line starting current.

38 Flygt 3102, 50Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

LT
P2 [kW]

3.5
420
3.0

2.5
421

2.0 423

H [m]

LT
12

10

2
420
421
423
0
0 10 20 30 40 50 60 70
Q [l/s]
WS005222A

Table 24: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 420 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 421 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 423 1500 6.3 40 .88 P,S,T,Z

Flygt 3102, 50Hz Technical Specification 39


N-pump, Premium Efficiency Motor (IE3)

MT
P2 [kW]
460

461
3
462
463
2 464

0
H [m]

MT
16

14

12

10
460
8

4
461
2
462
463
464
0
0 10 20 30 40 50
Q [l/s]
WS005223A

Table 25: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
3.5 4.7 460 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 461 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 462 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 463 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 464 1500 6.3 40 .88 P,S,T,Z

40 Flygt 3102, 50Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

SH
P2 [kW]

4.0
3.5
258
3.0
2.5
256
2.0
1.5

H [m]

SH
30

25

20

15

10

256 258
0
0 5 10 15 20 25 30
Q [l/s]
WS005215A

Table 26: 400 V, 50 Hz, 3–phase

Rated power Rated power Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
2.8 3.8 256 3000 5.9 64 .77 T,Z
4.5 6 256 3000 8.5 64 .86 P,S
4.5 6 258 3000 8.5 64 .86 P,S

Flygt 3102, 50Hz Technical Specification 41


Dimensions and Weight

Dimensions and Weight


Drawings, C-pump
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your sales representative for more information.
All dimensions are in mm.

Figure 1: LT, P-installation Figure 2: LT, P-installation

42 Flygt 3102, 50Hz Technical Specification


Dimensions and Weight

Figure 3: LT, P-installation Figure 4: LT, S-installation

Figure 5: LT, S-installation Figure 6: LT, T-installation

Flygt 3102, 50Hz Technical Specification 43


Dimensions and Weight

Figure 7: LT, T-installation Figure 8: LT, Z-installation

Figure 9: LT, Z-installation Figure 10: MT, P-installation

44 Flygt 3102, 50Hz Technical Specification


Dimensions and Weight

Figure 11: MT, S-installation Figure 12: MT, T-installation

Figure 13: MT, Z-installation Figure 14: HT/SH, P-installation

Flygt 3102, 50Hz Technical Specification 45


Dimensions and Weight

Figure 15: HT/SH, S-installation Figure 16: HT/SH, T-installation

Figure 17: HT/SH, Z-installation

Drawings, D-pump
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your sales representative for more information.
All dimensions are in mm.

46 Flygt 3102, 50Hz Technical Specification


Dimensions and Weight

Figure 18: MT, P-installation Figure 19: HT, P-installation

Figure 20: HT, P-installation

Drawings, F-pump
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your sales representative for more information.
All dimensions are in mm.

Flygt 3102, 50Hz Technical Specification 47


Dimensions and Weight

Figure 21: J-installation Figure 22: LT, P-installation

Figure 23: LT, S-installation

Drawings, M-pump
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your sales representative for more information.
All dimensions are in mm.

48 Flygt 3102, 50Hz Technical Specification


Dimensions and Weight

Figure 24: LT, F-installation Figure 25: LT, P-installation

Figure 26: HT, F-installation Figure 27: HT, P-installation

Drawings, N-pump
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your sales representative for more information.
All dimensions are in mm.

Flygt 3102, 50Hz Technical Specification 49


Dimensions and Weight

Figure 28: LT, P-installation Figure 29: LT, P-installation

Figure 30: LT, S-installation Figure 31: LT, S-installation

50 Flygt 3102, 50Hz Technical Specification


Dimensions and Weight

Figure 32: MT, P-installation Figure 33: MT, P-installation

Figure 34: MT, S-installation Figure 35: MT, S-installation

Flygt 3102, 50Hz Technical Specification 51


Dimensions and Weight

Figure 36: HT/SH, P-installation Figure 37: HT, S-installation

Figure 38: J-installation

52 Flygt 3102, 50Hz Technical Specification


Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company

We're 12,500 people unified in a common purpose: creating


innovative solutions to meet our world's water needs. Developing new
technologies that will improve the way water is used, conserved, and
re-used in the future is central to our work. We move, treat, analyze,
and return water to the environment, and we help people use water
efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with
customers who know us for our powerful combination of leading
product brands and applications expertise, backed by a legacy of
innovation.

For more information on how Xylem can help you, go to [Link]

Xylem Water Solutions AB Visit our Web site for the latest version of this
document and more information
Gesällvägen 33
174 87 Sundbyberg The original instruction is in English. All non-
English instructions are translations of the original
Sweden instruction.
Tel. +46-8-475 60 00 © 2012 Xylem Inc.
Fax +46-8-475 69 00
[Link]

883450_1.0_en.US_2012-07_TS_3102_50Hz