ASI
ASI
Fieldbus Communication
for Actuator Sensor
Interface Applications
Lumberg Automation™ Provides
Reliable Actuator Sensor Interface
Fieldbus Solutions for Industrial
Automation Applications Worldwide.
AS-Interface
Belden Industrial Solutions Here are a few more good reasons why Belden We’ll consult with you to develop a strategy —
is your best choice for industrial networking, or we’ll develop and implement your full design
For mission-critical applications, Belden is communications and control: — either way our staff is available to you.
the signal transmission partner that delivers
confidence in signal availability, integrity and • We have the expertise to integrate your Training
performance because only Belden can offer industrial and commercial networks.
Backed by years of meeting and exceeding
solutions that satisfy any requirement. • Our products are engineered to perform in the needs of a broad range of end-user
A majority of system failures occur within the tough and difficult environments.
applications, Belden is ideally suited to offer
signal transmission space, and trouble-shooting • We offer the broadest selection of products, beginners and networking experts alike the
can be very difficult and time-consuming. We for a complete, end-to-end Ethernet opportunity to expand their understanding of
want everyone to “Be Certain” that when solution. mission-critical industrial networks.
choosing Belden you receive Signal Availability • Our sales and engineering professionals can Belden has developed a series of training
— always there, Signal Integrity — always audit, recommend/design, configure and programs that are given by Belden-certified
trusted and secure, and Signal Performance — assemble the products and systems to your individuals — all experts in industrial
always when and where you need it. specific requirements. networking and cabling.
Belden has brought together a comprehensive • Our global manufacturing and distribution
line of industrial cabling, connectivity and network make our products available to Technical Support
networking devices, offering the most reliable you globally.
At Belden, our personnel are poised to assist our
communications solutions for your application. customers — ensuring maximum uptime and
Whether you are networking your devices to Offering Comprehensive reliability. And with offices in North America,
Service & Support
the controllers, connecting the controllers to Asia and Europe, Belden can respond globally.
the control room, relaying data between the Belden recognizes that comprehensive know-
control room, the engineering department, how is necessary to ensure an optimized, System Performance
and remote manufacturing sites — or all of the homogenous solution. We also know that If Belden designs it, we guarantee performance
above — Belden has the products you need to consultation, support and training requires — period. We are committed to ensuring world-
seamlessly connect your communications. more than just a general understanding of class signal connectivity and to significantly
the products, technologies and market trends. improve your operational up-time. All
From the petrochemical, automotive,
It requires a solid understanding of the Belden components are “designed” to deliver
pharmaceutical, power generation, pulp
application and the ability to provide the type optimum performance: from connectors, to
and paper, metals, food and beverage, or
of support that is needed — when and where it cable, to routers and switches. Based on this
general manufacturing plant to the corporate
is needed. It requires the four key service and comprehensive product portfolio, we have the
headquarters — and everywhere in between —
support areas that are critical to success: necessary industrial solutions DNA to deliver
Belden has your signal transmission solution.
Belden offers the most dependable network and reliability.
• Network Design
communications system performance in tough For more information on our service and
• Training
and mission-critical environments. support offering, including our warranties,
• Technical Support please go to the Belden web site at
Our Synergy Ensures • System Performance www.belden.com/industrial to locate
Continuous Performance a Belden sales representative near you.
Network Design
With the Hirschmann™ and Lumberg
Automation™ product line additions to Belden eliminates your design challenges
the Belden offering, our line of Complete because we understand the issues surrounding
Industrial Solutions is uniquely positioned to the design and operation of networks in
provide the best network and communications industrial and mission-critical environments.
infrastructure possible. Belden products and Our engineers are available to work with you
systems expertise means that you can maintain to deliver high-availability networks that
ongoing operations without interruption and meet your enterprise-wide IT needs. Whether
costly downtime — in any environment. it’s designing systems for Greenfield facilities,
or integrating into existing industrial IT
environments, our highly-trained staff lifts the
design burden from your shoulders to ours.
www.lumberg-automationusa.com 1-717-217-2299 3
The Lumberg Automation™ Brand Sets the Standard for Quality, Reliability and Service.
4 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Table of Contents
Table of Contents
About Belden® Industrial Solutions ...................................................................................................... 3
About Our Solutions ............................................................................................................................. 4
AS-Interface Introduction ..................................................................................................................... 6-7
www.lumberg-automationusa.com 1-717-217-2299 5
AS-Interface Introduction
Transmission media: Unshielded 2-wire cable for • Max. segment length: 100 m Bus cycle time
power supply (module electronics and sensors) • Standard slaves max. 5 ms in case of full
and data transmission (Manchester Encoding arrangement (31 slaves)
and optionally mechanically encoded flat or
• Just A or B slave per address max. 5 ms in case
round cable.
of full arrangement (31 slaves)
• A and B slave per address max. 10 ms in case
of full arrangement (62 slaves)
6 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
The New AS-i Specification Version 2.1 Very good electromagnetic resistance (EMC) and shieldedsystems.
With the introduced AS-i specification V. 2.1
Very good vibration and shock resistance.
some innovations have been integrated into the
AS-i system. The most important alteration is the
possibility to operate 62 (instead of 31) slaves UL approved.
in one network. This became possible by the
introduction of a differentiation between A and B UL/CSA approved.
slaves (e.g. 1A + 1B). To achieve that, the system
had to be designed with one output per slave less
(max. 4I/3O).
The new specification is downward compatible,
and old AS-i slaves can be operated in one
network together with new ones. In addition
to that, the processing of analog values was
improved. The transmission of analog values are
integrated in the master. This means that specific
function blocks need not be used any more.
www.lumberg-automationusa.com 1-717-217-2299 7
AS-Interface Module with 4-Digital Inputs
– Version 2.1 -
Pin Assignment
Bus Connection M8 Input M8
1 = AS-interface + 1 = +24 V
2 = AS-interface - 2 = GND (0 V)
4 = n.c. 4 = IN
8 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Technical Data
Environmental
Degree of protection IP 67
Operating temperature range -15°C (+5°F) to +60°C (+140°F)
Weight 100 g
Housing material PUR
Diagnostic
Indication LED red
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 9
AS-Interface Module with 4-Digital Inputs
– Version 2.1 -
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 3
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the inputs is implemented via the earthing contacts at the fastening holes.
10 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Diagnostic
Indication LED red
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 11
AS-Interface Module with 4-Digital Inputs
Pin Assignments
Bus connection M12 Input M12
1 = AS-Inerface + 1 = +24 V
2 = n.c. 2 = IN
3 = AS-Interface - 3 = GND (0 V)
4 = n.c. 4 = IN
5 = n.c.
12 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Diagnostic
Indication LED red
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 13
AS-Interface Module with 8-Digital Inputs
– Version 2.1 -
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the inputs is implemented via the earthing contacts at the fastening holes.
14 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Technical Data
Environmental
Note
Degree of protection IP 67
Operating temperature range -25°C (-13°F) to +80°C (+176°F) The input channels are connected together. That allows a greater connection
Weight 300 g flexibility (see pin assignment). In case of connection of a two-channel sensor to
Housing material PUR input socket 1 or 3 a further sensor must not be plugged to input socket 2 or 4
respectively due to the Y wiring of the inputs.
Bus system AS-Interface Version 2.1
AS-Interface profile S 0.A.E
I/O configuration 0 hex
ID code 1 hex
ID2 code (extended ID-code) E hex
Support A/B addressing yes
Diagnostic
Indication LED red
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 15
AS-Interface Module with 4-Digital Outputs
Pin Assignments
Output M12
1 = n.c.
2 = n.c.
3 = GND (0 V)
4 = OUT
5 = earth
16 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Technical Data
Environmental
Degree of protection IP 67
Operating temperature range -25°C (-13°F) to +80°C (+176°F)
Weight 200 g
Housing material PUR
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 17
AS-Interface Module with 4-Digital Outputs
Pin Assignments
Bus connection M12 Output M12
1 = AS-Inerface + 1 = n.c.
2 = 0 V AUX 2 = n.c.
3 = AS-Interface - 3 = GND (0 V)
4 = +24 V AUX 4 = OUT
5 = earth
18 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 19
AS-Interface Module with 8-Digital Outputs
– Version 2.1 -
Pin Assignments
Output 1 M12 Output 2 M12 Output 3 M12 Output 4 M12
1 = n.c. 1 = n.c. 1 = n.c. 1 = n.c.
2 = OUT 2 2 = n.c. 2 = OUT 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = OUT 1 4 = OUT 2 4 = OUT 3 4 = OUT 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the outputs is implemented via the earthing contacts at the fastening holes.
20 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 21
AS-Interface Module with 2-Digital Inputs and 2-Digital Outputs
– Version 2.1 -
Pin Assignments
Input 1 M12 Input 2 M12 Output 3 M12 Output 4 M12
1 = +24 V 1 = +24 V 1 = n.c. 1 = n.c.
2 = IN 2 2 = n.c. 2 = n.c. 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = OUT 3 4 = OUT 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
22 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 23
AS-Interface Module with 2-Digital Inputs and 2-Digital Outputs
Pin Assignments
Bus connection M12 Input M12 Output M12
1 = AS-Inerface + 1 = +24 V 1 = n.c.
2 = 0 V AUX 2 = IN 2 = n.c.
3 = AS-Interface - 3 = GND (0 V) 3 = GND (0 V)
4 = +24 V AUX 4 = IN 4 = OUT
5 = n.c. 5 = earth
24 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 25
AS-Interface Module with 4-Digital Inputs and 3-Digital Outputs
– Version 2.1 -
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the outputs is implemented via the earthing contacts at the fastening holes.
26 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 27
AS-Interface Module with 4-Digital Inputs and 4-Digital Outputs
– Version 2.1 -
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
28 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 29
AS-Interface Module with 4-Digital Inputs and 4-Digital Outputs
Pin Assignments
Bus connection M12 Input M12 Output M12
1 = AS-Inerface + 1 = +24 V 1 = n.c.
2 = 0 V AUX 2 = IN 2 = n.c.
3 = AS-Interface - 3 = GND (0 V) 3 = GND (0 V)
4 = +24 V AUX 4 = IN 4 = OUT
5 = n.c. 5 = earth
30 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 31
AS-Interface Module with 4-Digital Inputs and 4-Digital Outputs
Pin Assignments
Bus connection M12 Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = AS-Interface + 1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = 0 V AUX 2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = AS-Interface - 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = +24 V AUX 4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the outputs is implemented via the earthing contacts at the fastening holes.
32 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 33
AS-Interface Module with 4-Digital Inputs and 4-Digital Outputs
Pin Assignments
Bus connection M12 Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = AS-Interface + 1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = 0 V AUX 2 = IN 2 2 = n.c. 2 = n.c. 2 = n.c.
3 = AS-Interface - 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = +24 V AUX 4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the outputs is implemented via the earthing contacts at the fastening holes.
34 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 35
AS-Interface Module with 4-Digital Inputs and 4-Digital Outputs
– Version 3.0 -
Byte 0 - - - - I-4 I-3 I-2 I-1 U-AS-i green AS-Interface power supply active
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
36 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Technical Data
Environmental Outputs Type 2 A acc. to
IEC 61131-2
Degree of protection IP 67 Rated output current 2 A per channel
Temperature range -25°C / +80°C Short circuit-proof yes
Weight 300 g Max. output current 4 A per module
Housing PUR Overload-proof yes
Number of digital channels 4
Bus System AS-Interface V3.0 Channel type N.O. p-switching
AS-Interface profile S 7.A.7 Channel status indicator LED yellow per channel
I/O configuration 7 hex
ID code A hex Diagnostic
ID2 code (extended ID-code) 7 hex Indication LED red
Support A/B addressing yes
Included in delivery / accessories
Electronics Power Supply AS-Interface Dust covers M12 2 pieces
Rated voltage AS-Interface net Attachable labels 10 pieces
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA Note
Reverse polarity protection yes
The input- and output channels are connected together. That allows a greater
Indication LED green
connection flexibility (see pin assignment). In case of connection of a two-chan-
Input Power Supply nel sensor/actuator to input/output socket 1 or 3 a further sensor/actuator must
Voltage range (AS-Interface net) 17-30 V not be plugged to input/output socket 2 or 4 respectively due to the Y wiring of
Total current of all sensors max. 250 mA the inputs/outputs.
Short circuit-proof yes
Part Number
www.lumberg-automationusa.com 1-717-217-2299 37
AS-Interface Module with 4-Digital Inputs and 4-Digital Outputs
– Version 3.0 -
Byte 0 - - - - I-4 I-3/4 I-2 I-1/2 U-AS-i green AS-Interface power supply active
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
1 = +24 V 1 = +24 V 1 = +24 V 1 = +24 V
2 = IN 2 2 = n.c. 2 = IN 4 2 = n.c.
3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V) 3 = GND (0 V)
4 = IN 1 4 = IN 2 4 = IN 3 4 = IN 4
5 = earth 5 = earth 5 = earth 5 = earth
The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
38 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Technical Data
Environmental Outputs Type 2 A acc. to
IEC 61131-2
Degree of protection IP 67 Rated output current 2 A per channel
Temperature range -25°C / +80°C Short circuit-proof yes
Weight 300 g Max. output current 4 A per module
Housing PUR Overload-proof yes
Number of digital channels 4
Bus System AS-Interface V3.0 Channel type N.O. p-switching
AS-Interface profile S 7.A.7 Channel status indicator LED yellow per channel
I/O configuration 7 hex
ID code A hex Diagnostic
ID2 code (extended ID-code) 7 hex Indication LED red
Support A/B addressing yes
Included in delivery / accessories
Electronics Power Supply AS-Interface Dust covers M12 2 pieces
Rated voltage AS-Interface net Attachable labels 10 pieces
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA Note
Reverse polarity protection yes
The input- and output channels are connected together. That allows a greater
Indication LED green
connection flexibility (see pin assignment). In case of connection of a two-chan-
Input Power Supply nel sensor/actuator to input/output socket 1 or 3 a further sensor/actuator must
Voltage range (AS-Interface net) 17-30 V not be plugged to input/output socket 2 or 4 respectively due to the Y wiring of
Total current of all sensors max. 250 mA the inputs/outputs.
Short circuit-proof yes
Part Number
www.lumberg-automationusa.com 1-717-217-2299 39
AS-Interface Passive Modules, 4-Ports
Pin Assignments
Bus connection M12 Input 1 M12
1 = earth 1 = AS-Interface +
2 = +24 V 2 = 0 V AUX
3 = GND (0 V) 3 = AS-Interface -
4 = n.c. 4 = +24 V AUX
5 = n.c. 5 = earth
6 = n.c.
40 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Technical Data
Environmental
Degree of protection IP 67
Operating temperature range -25°C (-13°F) to +80°C (+176°F)
Housing material PUR
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 41
AS-Interface Junction Branches
Technical Data
Environmental
Degree of protection IP 65
Housing material PA
Nominal current at 40°C 4A
Note
– insertion of the AS-Interface flat cable (yellow) in
cable shaft “LINE1“
– insertion of the additional voltage supply (black
flat cable) in cable shaft “LINE 2“
Technical Data
Environmental
Degree of protection IP 65
Housing material PA
Nominal current at 40°C 8A
Note
Please be aware that only two wires with the same
function may be inserted into this AS-Interface
branch. This means that either only the yellow or
only the black AS-Interface flat cable may be used.
Pin Assignments
Cable M12 - 5 Poles
1 = AS-Interface + brown
2 = 0 V AUX white
3 = AS-Interface - blue 1 = AS-Interface +
4 = +24 V AUX black 2 = 0 V AUX
5 = earth green/yellow 3 = AS-Interface -
4 = +24 V AUX
5 = earth
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
42 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
AS-Interface Accessories
AS-Interface connector for direct connection AS-Interface connector for direct connection
to a wired male connector: reusable access to two wired male connectors: reusable access
technology to IEC 60352-6. AS-Interface technology to IEC 60352-6. AS-Interface
connector. 0911 ANC 406 is included with the connector 0911 ANC 406 is included with the
delivered product. delivered product.
Pin Assignments
2-Poles 2-Poles
1 = brown 1 = brown
2 = blue 2 = blue
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 43
AS-Interface Accessories
AS-Interface cable connector, used for AS-Interface connector for AS-Interface cables. AS-Interface cable connector, used for
distribution of connections or as connector: distribution of connections or as connector:
reusable access technology to IEC 60352-6. AS- reusable access technology to IEC 68 and
Interface connector 0911 ANC 406 is included DIN 41611, hexagon screw in stainless steel, 4
with the delivered product. poles. AS-Interface connector 0911 ANC 415 is
included with the delivered product.
– especially designed for food and
beverage equipment –
Technical Data
Molded body PBT
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
44 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
AS-Interface Accessories
This AS-Interface Handheld controller serves The addressing adaptor is able to address the
to address the AS-Interface sensors, actuators AS-Interface flat cable modules with existing
and round cable modules. The mechanical handheld addressing units, length 0.35 m.
connection is made by a mating M12 connector.
– suitable to addressing unit 0913 ATL 003 –
AS-Interface flat cable modules are connected
using the addressing adaptor type 0913 ATL
002/0.35 M. With this addressing equipment,
all types of AS-Interface modules (including
equipment with ASInterface Version 2.1) can
be addressed.
Important Note
The equipment with AS-Interface Version 2.1 are
not addressable with the previous address module
0913 ATL 001.
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 45
AS-Interface Accessories
Environmental
Degree of protection IP 67
Temperature range -25°C / +80°C
Materials
Housing / Molded body TPU, self-extinguishing
Insert TPU, self-extinguishing
Contact Male connector: CuZn, prenickeled and
0.8 microns gold-plated
Female connector: CuZn, prenickeled and
0.3 microns gold-plated
AS-Interface cordset, doubleended, M12 male
Receptacle shell / knurled screw/
connector and M12 female connector with self-
nut / hexagon screw/nut / sleeve CuZn, nickel-plated
locking threaded joint.
O-ring FKM (only female connector)
Electrical data
Nominal current at 40°C 4A
Nominal voltage 240 V
Rated voltage 250 V
Test voltage 2.0 kV eff. / 60 s
Insulation resistance > 109 :
Pollution degree 3
Pin Assignments
4-Poles
1 = brown
2 = white
3 = blue
4 = black
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
46 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
AS-Interface Accessories
Part Number
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
www.lumberg-automationusa.com 1-717-217-2299 47
Part Number Index
Part Number Page No. Part Number Page No. Part Number Page No.
0910 ASL 132 12-13 0910 ASL 438 38-39 0911 ANC 410/1 M 43
0910 ASL 133 18-19 0910 ASL 501 8-9 0911 ANC 410/2 M 43
0910 ASL 134 24-25 0911 ANC 002/5 M 40-41 0911 ANC 410/5 M 43
0910 ASL 135 30-31 0911 ANC 002/10 M 40-41 0911 ANC 410/10 M 43
0910 ASL 146 36-37 0911 ANC 101 42 0911 ANC 410/15 M 43
0910 ASL 403 16-17 0911 ANC 401 42 0911 ANC 413 44
0910 ASL 408 28-29 0911 ANC 403 40-41 0911 ANC 415 44
0910 ASL 409 10-11 0911 ANC 406 44 0913 ANC 409 47
0910 ASL 410 22-23 0911 ANC 407/2 M 43 0913 ATL 002/0.35 M 45
0910 ASL 412 14-15 0911 ANC 407/5 M 43 0913 ATL 003 45
0910 ASL 414 26-27 0911 ANC 407/10 M 43 0915 034 101/1 M 46
0910 ASL 419 20-21 0911 ANC 408 44 0915 034 101/3 M 46
0910 ASL 424 32-33 0911 ANC 410/0.3 M 43 0915 034 101/5 M 46
0910 ASL 425 34-35 0911 ANC 410/0.5 M 43
48 1-717-217-2299 www.lumberg-automationusa.com
AS-Interface
Regarding the details in this catalog: Alterations may have been made to the product after the editorial deadline for this publication, namely 03/01/2011. The manufacturer
reserves the right to alter the construction and form, manufacture different shades and amend the scope of delivery during the delivery period insofar as the alterations
and differences are acceptable to the buyer while allowing for the seller’s interests. Insofar as the seller or the manufacturer uses signs or numbers to mark the order or
the ordered item, no rights may be derived from this alone. The illustrations may also contain accessories and special equipment which are not part of the mass-produced
scope of delivery. Color differences are attributable to technical aspects of the printing process. This publication may also contain types and support services that are not
made available/rendered in some countries. The information/details in this publication merely contain general descriptions or performance factors which, when applied in an
actual situation, do not always correspond with the described form and may be amended by way of the further development of products. The desired performance factors
shall only be deemed binding if these are expressly agreed on conclusion of the contract. This brochure will be used internationally. However, comments on statutory, legal,
and fiscal provisions and effects only apply to the Federal Republic of Germany at the time of the editorial deadline for this publication. Please consult your pertinent seller
about the provisions and effects that apply to your country and regarding the latest biding version.
www.lumberg-automationusa.com
GLOBAL LOCATIONS