0% found this document useful (0 votes)
385 views31 pages

HDAF 905 Internet

Cincinnati Fan is a company that specializes in industrial air handling products up to 125 HP, offering a wide variety of standard and customized fans, blowers, and accessories that can be manufactured and shipped within 10-15 days; they provide 7 standard arrangements for direct drive or v-belt configurations, as well as options for accessories, materials, and mounting configurations; the document highlights the advantages of their products and arrangements, and provides an efficiency comparison of their airfoil wheel design versus a backward inclined wheel design.

Uploaded by

alex
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
385 views31 pages

HDAF 905 Internet

Cincinnati Fan is a company that specializes in industrial air handling products up to 125 HP, offering a wide variety of standard and customized fans, blowers, and accessories that can be manufactured and shipped within 10-15 days; they provide 7 standard arrangements for direct drive or v-belt configurations, as well as options for accessories, materials, and mounting configurations; the document highlights the advantages of their products and arrangements, and provides an efficiency comparison of their airfoil wheel design versus a backward inclined wheel design.

Uploaded by

alex
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ialist

ling Spec
Hand
al Air
stri
and Indu
OEM
HDAF
AIRFOIL
BLOWERS

CLASS II
CLASS IIP
CLASS III

7697 Snider Road, Mason, OH 45040-9135


Telephone: 513-573-0600
Visit us at www.cincinnatifan.com for more information.
Cat. No. HDAF-307
Supersedes HDAF-905
P roduct
e h i n d Its
StandsB
any That
A Comp Cincinnati Fan can provide:
• Technical evaluation for correct
performance conditions.
• Review of air stream and ambient
conditions that require special
attention.
Since the founding of Cincinnati Fan in 1956, the • Selection of proper components to
company’s mission has been to provide quality meet required design specifications.
products at competitive prices, backed by depend- • Selection of proper accessories.
able service. • System analysis for proper fan
This mission is carried out by specializing in the design.
market for industrial air handling products up to 125 Cincinnati Fan operates in a modern facility specif-
HP. But specialization does not mean the product ically designed for world class manufacturing
line is small. Cincinnati Fan offers a wide variety of enabling us to build standard products to order,
standard and customized products, production flex- including accessories, and ship within 10 to 15
ibility, and customer responsiveness. working days.
Cincinnati Fan has over 170 experienced sales With support like this, you can be sure your
engineers across the U.S. and Canada ready to Cincinnati Fan product will be well-built and will
serve your air handling needs. provide maximum dependability and longevity.
Visit us at www.cincinnatifan.com for more information.

EFFICIENCY OF AIRFOIL WHEEL vs. BACKWARD INCLINED WHEEL


Airfoil wheels provide the highest
efficiency of all centrifugal fan designs.
The curve overlays at right comparing an
HDAF-220 and HDBI-220 illustrates a
10% increase in static efficiency for the
airfoil design versus the backward inclined
design in the normal selection range. This
benefit results in lower brake horsepower
consumption and a reduction in sound
levels of 2-6 dBA.

2
ADVANTAGES OF DIRECT DRIVE ARRANGEMENT #4 & #4HM
All sizes available in 100% to 50% widths in 5% increments

ADVANTAGES OPTIONAL HORIZONTAL


• Compact - requires less space. MOUNTING
• Weighs Less - requires less supporting structure. Ideal for bag house or other equipment requiring the
simplicity of a horizontally mounted fan. Motors are
• Less Maintenance - no belts or fan bearings to limited to frame 365T maximum.
replace.
• Less Expensive - above features result in lower first This mounting is available on all sizes. All horizontal
cost and lower maintenance cost. mount housings are non-reversible. Inlet flange is
optional and must be added if required. Supporting
• More Ratings - the combination of several motor equipment must be adequate to support weights
speeds and eleven fan widths results in a vast shown on page 22 plus motor weight.
selection of direct drive ratings.
• Temperature - good up to 200°F. (93°C.)

HDAF ARRANGEMENT #9 FEATURES


A) Airfoil blades are fabricated of high-strength steel to assure H
long lasting, efficient operation.
B C
B) Turned, ground and polished shafting assures smooth
operation. A rust preventive coating is applied prior to shipment. G
C) Heavy-duty, self-aligning, relubricatable, ball bearings in cast-
iron pillow blocks. Bearings are selected for optimal performance
depending on fan size and class with an L10 life of 30,000 hours
minimum.
D) Bearing base is heavy steel construction with internal supports
to maximize rigidity and assure long equipment life. Arrangement A
#1 fans can be converted to Arrangement #9 with the addition of
the motor slide base.
E) Inlet side support is used to assure a vibration-free, stable
E
housing.
F) Slip collar inlet (not shown) is used for duct work connection.
Flanged inlet optional.
G) Inlet bell is designed for smooth air entrance into the wheel
inlet for maximum efficiency. D
H) Reversible housing provides increased configuration flexibility.
Removable side plates allow the wheel to be removed from the
motor or inlet side of the housing. Housings are rotatable in 45 NOTE: HDAF-330 and HDAF-360
degree increments. Wheels are not reversible. See note at right. housings are not rotatable or reversible.
3
SEVEN STANDARD ARRANGEMENTS

ARRANGEMENT 1 (V-BELT DRIVE) ARRANGEMENT 4HM and 4 (DIRECT DRIVE)


• Motor not mounted on bearing base. • Motor mounted on motor base.
• Wheel mounted on fan shaft with two pillow block bearings. • Wheel mounted on motor shaft.
• Maximum temperature of standard design: 300°F. (149°C.); • Maximum temperature of standard design:
high temperature designs up to 750°F. (398°C.) 200°F (93°C.); high temperature design not available.

(Shown with shaft/coupling guard removed)


ARRANGEMENT 8 (DIRECT DRIVE) ARRANGEMENT 9 (V-BELT DRIVE)
• Motor mounted on motor base extending beyond the • Motor mounted on an adjustable slide base on
bearing base. Shaft/coupling guard is standard. the side of the bearing base.
• Wheel mounted on fan shaft with two pillow block bearings. • Wheel mounted on fan shaft with two pillow block
• Maximum temperature of standard design: 300°F. (149°C.); bearings.
high temperature designs up to 750°F. (398°C.) • Maximum temperature of standard design: 300°F. (149°C.)
high temperature designs up to 750°F. (398°C.)

(Shown with weather cover removed)


ARRANGEMENT 9CB (V-BELT DRIVE) ARRANGEMENT 10 (V-BELT DRIVE)
• Same as Arrangement 9 except motor and fan • Motor mounted on adjustable base under the fan shaft.
are mounted on a common channel base. • Wheel mounted on fan shaft with two pillow block
• Maximum temperature of standard design: bearings.
300°F. (149°C.); high temperature designs up to • Maximum temperature of standard design: 300°F.
750°F. (398°C.) (149°C.); high temperature design not available.

4
OPTIONAL ACCESSORIES

Shaft Seal Outlet Damper Belt Guard


Teflon shaft seal good to 400°F. All dampers are 1 or 2 blade. Opposed blade
Belt guard standard on Arrangement
(204°C.) Ceramic fiber gasket material construction is standard.
9 and 9CB only. Painted safety
with steel cover plate above 400°F. yellow.
(205°C.)

Drain Connection
3/4" pipe coupling welded to lowest
point of housing. Not required on BH
discharge position.

Inspection Door
Bolted or quick-release doors
positioned as specified on scroll. Rubber
gasket standard up to 250°F. (121°C.)
Inlet Vane Control Ceramic fiber gasket standard at
Linkage assembly is external on smaller temperatures above 250°F (122°C.).
sizes, internal on larger sizes. Inlet vane
depth varies with inlet diameter. Contact
your local Cincinnati Fan sales
representative for dimensions. Shaft and/or
Heat Slinger Guard
Guard available on Arrangement 1, 9
and 9CB. Covers bearings and shaft
between fan housing and belt guard.
Has extended lube lines. Standard on
high temperature fans above 301°F.
DANGER (150°C.) Painted safety yellow.

All fans & blowers shown have


rotating parts and pinch points.
Severe personal injury can result if Inlet & Outlet Flanges
operated without guards. Stay away Flanges on inlet and outlet available
from rotating equipment unless it is where installation requires tight duct
disconnected from its power connections. Standard hole pattern
source. furnished. Outlet flange not available
on some discharge positions. Outlet Inlet & Outlet Guards
Read operating instructions. flange standard on all sizes 270 Ring guard on inlet and expanded
through 360. See page 31 for metal on discharge. Meet OSHA
dimensions. approval.

5
SPARK-RESISTANT CONSTRUCTION
For AMCA Type A or B spark resistant construction, please contact your local Cincinnati Fan sales
representative.
Type C: Consists of aluminum inlet bell and aluminum plate on drive side of the fan. Maximum Temperature
is the same as for high temperature construction below for each arrangement.

WARNING
The use of aluminum or aluminum alloys in the presence of steel which has been
allowed to rust requires special consideration. Research by the U.S. Bureau of
Mines and others has shown that aluminum impellers rubbing on rusty steel may
cause high intensity sparking.
The use of the above Standard in no way implies a guarantee of safety for any level
of spark resistance. Spark-resistant construction also does not protect against igni-
tion of explosive gases caused by catastrophic failure or from any airstream material
that may be present in a system.

HIGH TEMPERATURE CONSTRUCTION


Standard Construction: Arrangements 1, 8, 9, 9CB and 10 suitable to 300°F. (149°C.) MAXIMUM
TEMPERATURE
Arrangement 4 and 4HM suitable to 200°F. (93°C.). RANGE RPM REDUCTION
FACTOR†
301°-400°F. (150°-204°C.) Construction: Standard fan with heat slinger and shaft/slinger
Up to 175˚F. 0%
guard. Arrangements 1, 8, 9 and 9CB only. 176˚-200˚ 2%
401°- 600°F. (205°-316°C.) Construction: Standard fan with heat slinger, shaft/slinger 201˚-300˚ 4%
guard, high temperature shaft seal, gasketing and paint. Arrangements 1, 8, 9 and 301˚-400˚ 7%
9CB only. 401˚-500˚ 11%
601°- 750°F. (317°-398°C.) Construction: Standard fan with heat slinger, shaft/slinger 501˚-600˚ 15%
601˚-700˚ 20%
guard, high temperature bearings, shaft seal, gasketing and paint. Arrangements 701˚-750˚ 30%
1, 8, 9 and 9CB only.
† Steel wheels only.

TEMPERATURE - ALTITUDE CONVERSIONS


AIR ALTITUDE IN FEET ABOVE SEA LEVEL Fan performance tables are developed using standard
TEMP.
F˚ 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 air which is 70°F., 29.92" barometric pressure and .075
0˚ .87 .91 .94 .98 1.01 1.05 1.09 1.13 1.17 1.22 1.26 Ibs. per cubic foot. Density changes resulting from
40˚ .94 .98 1.02 1.06 1.10 1.14 1.19 1 23 1.28 1.32 1.36 temperature or barometric pressure variations (such as
70˚ 1.00 1.04 1.08 1.12 1.16 1.20 1.25 1.30 1.35 1.40 1.45 higher altitudes) must be corrected to standard
80˚ 1.02 1.06 1.10 1.14 1.19 1.23 1.28 1.33 1.38 1.43 1.48 conditions before selecting a fan based on standard
100˚ 1.06 1.10 1.14 1.19 1.23 1.28 1.33 1.38 1.43 1.48 1.54 performance data.
120˚ 1.09 1.14 1.18 1.23 1.28 1.32 1.38 1.43 1.48 1.53 1.58 Temperature and/or altitude conversion factors are used
140˚ 1.13 1.18 1.22 1.27 1.32 1.37 1.42 1.48 1.54 1.58 1.65 in making corrections to standard conditions.
160˚ 1.17 1.22 1.26 1.31 1.36 1.42 1.47 1.53 1.59 1.64 1.70
180˚ 1.21 1.26 1.30 1.36 1.41 1.46 1.52 1.58 1.64 1.70 1.75
EXAMPLE:
Select a belt driven fan to deliver 8400 CFM at 8" SP at
200˚ 1.25 1.29 1.34 1.40 1.45 1.51 1.57 1.63 1.69 1.75 1.81
200°F., and 7000' altitude.
250˚ 1.34 1.39 1.45 1.50 1.56 1.62 1.68 1.74 1.82 1.88 1.94
STEP 1. From the table, the conversion factor is 1.63.
300˚ 1.43 1.49 1.55 1.61 1.67 1.74 1.80 1.87 1.94 2.00 2.08
STEP 2. Correct static pressure is: 1.63 x 8" SP =
350˚ 1.53 1.59 1.65 1.72 1.78 1.85 1.92 2.00 2.07 2.14 2.22 13.04" SP at standard conditions.
400˚ 1.62 1.69 1.75 1.82 1.89 1.96 2.04 2.12 2.20 2.27 2.35 STEP 3. Check HDAF catalog for 8400 CFM at 13" SP.
450˚ 1.72 1.79 1.86 1.93 2.00 2.08 2.16 2.24 2.33 2.41 2.50 We select a belt driven HDAF-200, Class IIP at 3335
500˚ 1.81 1.88 1.96 2.03 2.11 2.19 2.28 2.36 2.46 2.54 2.62 RPM and 22.77 BHP.
550˚ 1.91 1.98 2.06 2.14 2.22 2.30 2.40 2.49 2.58 2.68 2.77 STEP 4. Correct the BHP for the lighter air:
600˚ 2.00 2.08 2.16 2.24 2.33 2.42 2.50 2.61 2.71 2.80 2.90 22.77 ÷ 1.63 = 13.97 BHP. A 15 HP motor will suffice
650˚ 2.10 2.18 2.26 2.35 2.44 2.54 2.63 2.74 2.84 2.94 3.04 at 200°F., and 7000' but not at standard conditions.
700˚ 2.19 2.27 2.36 2.46 2.55 2.65 2.75 2.86 2.97 3.06 3.18 Special motor insulation may be required due to
750˚ 2.28 2.37 2.47 2.56 2.66 2.76 2.87 2.98 3.10 3.19 3.31 altitude.

6
DIRECT DRIVE RATING TABLES FOR FULL (100%) WIDTH FANS
CFM an BHP at Static Pressures Shown • Ratings at 70° F., .075 Density, Sea Level
Sizes 120-160 have Class II wheels. Sizes 180-240 have Class IIP wheels. Sizes 270-360 have Class III wheels.

Wheel 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP


MODEL RPM Type CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
HDAF-120 1750 HDAF 993 .29
SQAF 1002 .29
3500 HDAF 2879 2.21 2608 2.28 2320 2.31 1985 2.29 1524 2.15 270 1.51
SQAF 2734 2.14 2509 2.26 2275 2.33 2003 2.35 1650 2.28 1144 2.08
HDAF-130 1750 HDAF 1491 .47
SQAF 1457 .47 501 .38
3500 HDAF 3917 3.57 3620 3.67 3314 3.74 2982 3.76 2597 3.71 2087 3.52
SQAF 3680 3.39 3432 3.56 3183 3.68 2913 3.76 2601 3.76 2206 3.66
HDAF-150 1750 HDAF 2289 .77 1436 .76
SQAF 2188 .83 1405 .86
3500 HDAF 5568 5.72 5260 5.94 4928 6.09 4578 6.19 4213 6.25 3827 6.27
SQAF 5239 6.15 4955 6.32 4671 6.49 4376 6.66 4058 6.81 3705 6.92
HDAF-160 1750 HDAF 3209 1.23 2377 1.26
SQAF 3056 1.32 2312 1.40 1053 1.28
3500 HDAF 7478 9.14 7147 9.45 6792 9.69 6419 9.87 6031 9.99 5629 10.07
SQAF 7055 9.89 6739 10.11 6429 10.34 6113 10.58 5784 10.80 5434 10.99
HDAF-180 1750 HDAF 4574 1.83 4031 2.02 3333 2.08
SQAF 5174 2.51 4648 2.70 4006 2.74 3037 2.60
3500 HDAF 9885 13.17 9638 13.82 9393 14.27 9148 14.66 8903 15.05 8632 15.43
SQAF 11136 18.68 10874 19.16 10611 19.63 10348 20.11 10085 20.49 9822 20.85
HDAF-200 1750 HDAF 6128 2.85 5556 3.10 4910 3.32 3930 3.22
SQAF 6918 3.90 6342 4.16 5706 4.31 4955 4.33 2562 3.30
3500 HDAF 13064 20.65 12794 21.50 12524 22.24 12256 22.76 11988 23.27 11720 23.79
HDAF-220 1750 HDAF 8357 3.90 7655 4.56 6874 4.84 5919 4.81 2593 3.51
SQAF 9801 7.13 9257 7.51 8669 7.76 7952 7.60 7014 7.05 5301 6.80
HDAF-240 1750 HDAF 11316 6.14 10550 7.00 9771 7.92 8840 7.79 7726 7.80 3990 6.01
SQAF 13227 11.44 12651 12.04 12006 12.37 11359 12.70 10496 12.21 9518 11.44
HDAF-270 1750 HDAF 17215 14.49 16558 15.39 15859 16.23 15048 16.94 14222 17.57 13254 17.52
SQAF 19339 19.26 18632 20.02 17900 20.77 17039 21.50 16178 22.23 15126 22.28
HDAF-300 1750 HDAF 23786 24.25 23056 25.48 22326 26.71 21488 27.78 20587 28.75 19685 29.71
SQAF 26746 32.44 25961 33.48 25175 34.51 24304 35.53 23347 36.54 22390 37.55
HDAF-330 1750 HDAF 31828 38.71 31025 40.35 30222 41.99 29419 43.62 28442 44.94 27450 46.23
SQAF 35611 51.56 34748 52.93 33885 54.30 33022 55.68 32013 57.02 30962 58.35
HDAF-360 1750 HDAF 41488 59.41 40612 61.53 39736 63.66 38859 65.78 37953 67.84 36872 69.52

Wheel 7"SP 8"SP 9"SP 10"SP 11"SP 12"SP


MODEL RPM Type CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
HDAF-120 3500 SQAF 492 1.79
HDAF-130 3500 HDAF 963 2.84 Contact your local Cincinnati Fan sales
SQAF 1672 3.41 1002 3.05 office for fan performances at 1150 RPM.
HDAF-150 3500 HDAF 3399 6.23 2872 6.06
SQAF 3298 6.96 2810 6.90 2217 6.70 1504 6.31 464 5.50
HDAF-160 3500 HDAF 5207 10.10 4755 10.07 4242 9.95 3584 9.61
SQAF 5052 11.15 4625 11.24 4135 11.24 3562 11.10 2888 10.79 2105 10.27
HDAF-180 3500 HDAF 8347 15.81 8062 16.19 7777 16.57 7458 16.81 7063 16.73 6667 16.65
SQAF 9559 21.21 9295 21.57 9010 21.82 8678 21.84 8347 21.86 8012 21.89
HDAF-200 3500 HDAF 11425 24.29 11113 24.79 10800 25.29 10488 25.78 10176 26.28 9820 26.57
HDAF-220 1750 SQAF 786 3.74
HDAF-240 1750 SQAF 7589 11.17 4696 9.23
HDAF-270 1750 HDAF 11686 16.92 5348 11.49
SQAF 14012 22.10 12811 21.74 10950 20.60 5165 15.06
HDAF-300 1750 HDAF 18618 29.70 17542 29.62 14988 27.89 5687 17.61
SQAF 21287 37.91 20048 37.66 18778 37.33 17442 36.84 15521 35.49 6754 24.72
HDAF-330 1750 HDAF 26459 47.52 25337 47.87 24154 47.77 22797 47.44 19596 44.61 9040 30.36
SQAF 29911 59.68 28804 60.72 27444 60.39 26084 60.06 24666 59.56 23198 58.91
HDAF-360 1750 HDAF 35790 71.19 34708 72.87 33567 74.03 32275 73.90 30984 73.78 29249 72.93

Wheel 13" SP 14" SP 15" SP 16" SP 17" SP 18" SP


MODEL RPM Type CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
HDAF-160 3500 SQAF 1139 9.45
HDAF-180 3500 HDAF 6173 16.43 5547 16.02 2938 11.83
SQAF 7655 21.93 7298 21.97 6942 22.02 6073 20.76 2931 14.85
HDAF-200 3500 HDAF 9387 26.46 8953 26.35 8520 26.25 7859 25.76 5178 21.19 3803 18.59
HDAF-330 1750 SQAF 21730 58.25 12177 44.11 10079 42.05
HDAF-360 1750 HDAF 25758 69.25 15045 52.68
Performance shown is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances (accessories).
These performance ratings require a larger motor frame size even though the BHP is available in a smaller motor frame. See pages 23, 24 or 27 for the
minimum motor frame size for each fan model.

7
DIRECT DRIVE RATING TABLES
for partial width fans with two wheel types
CFM and BHP at Static Pressures Shown • Ratings at 70°F., .075 Density, Sea Level

Wheel Fan 1" SP 2" SP 3" SP 4" SP 5" SP 6" SP


MODEL RPM Type Width CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
HDAF-120 3500 HDAF 50% 1440 1.11 1304 1.14 1160 1.16 993 1.14 762 1.08 135 .75
SQAF 50% 1367 1.07 1255 1.13 1138 1.17 1002 1.18 825 1.14 572 1.04
HDAF 75% 2159 1.66 1956 1.71 1740 1.73 1489 1.72 1143 1.61 202 1.13
SQAF 75% 2051 1.61 1882 1.69 1706 1.75 1502 1.76 1237 1.71 858 1.56
HDAF-130 3500 HDAF 50% 1959 1.79 1810 1.83 1657 1.87 1491 1.88 1299 1.85 1043 1.76
SQAF 50% 1840 1.70 1716 1.70 1591 1.84 1457 1.88 1300 1.88 1103 1.83
HDAF 75% 2938 2.68 2715 2.75 2485 2.80 2237 2.82 1948 2.78 1565 2.64
SQAF 75% 2760 2.55 2574 2.67 2387 2.76 2185 2.82 1950 2.82 1655 2.74
HDAF-150 1750 HDAF 50% 1145 .39 718 .38
SQAF 50% 1094 .42 703 .43
HDAF 75% 1717 .58 1077 .57
SQAF 75% 1641 .62 1054 .65
3500 HDAF 50% 2784 2.86 2630 2.97 2464 3.05 2289 3.10 2107 3.13 1913 3.14
SQAF 50% 2620 3.07 2477 3.16 2335 3.25 2188 3.33 2029 3.41 1853 3.46
HDAF 75% 4176 4.29 3945 4.45 3696 4.57 3434 4.65 3160 4.69 2870 4.70
SQAF 75% 3929 4.61 3716 4.74 3503 4.87 3282 5.00 3044 5.11 2779 5.19
HDAF-160 1750 HDAF 50% 1605 .62 1189 .63
SQAF 50% 1528 .66 1156 .70 526 .64
HDAF 75% 2407 .93 1783 .94
SQAF 75% 2292 .99 1734 1.05 789 .96
3500 HDAF 50% 3739 4.57 3574 4.73 3396 4.85 3209 4.93 3015 5.00 2814 5.03
SQAF 50% 3527 4.95 3370 5.05 3214 5.17 3056 5.29 2892 5.40 2717 5.50
HDAF 75% 5608 6.86 5360 7.09 5094 7.27 4814 7.40 4523 7.49 4221 7.55
SQAF 75% 5291 7.42 5055 7.58 4821 7.76 4585 7.93 4338 8.10 4075 8.25
HDAF-180 1750 HDAF 50% 2287 .92 2016 1.01 1667 1.04
SQAF 50% 2587 1.26 2324 1.35 2003 1.37 1519 1.30
HDAF 75% 3431 1.37 3023 1.52 2500 1.56
SQAF 75% 3881 1.88 3486 2.03 3005 2.06 2278 1.95
3500 HDAF 50% 4943 6.59 4819 6.91 4697 7.14 4574 7.33 4452 7.53 4316 7.72
SQAF 50% 5568 9.34 5437 9.58 5306 9.82 5174 10.06 5043 10.25 4911 10.43
HDAF 75% 7414 9.88 7229 10.37 7045 10.70 6861 11.00 6677 11.29 6474 11.57
SQAF 75% 8352 14.01 8156 14.37 7958 14.72 7761 15.08 7564 15.37 7367 15.64
HDAF-200 1750 HDAF 50% 3064 1.43 2778 1.55 2455 1.66 1965 1.61
SQAF 50% 3459 1.95 3171 2.08 2853 2.16 2478 2.17 1281 1.65
HDAF 75% 4596 2.14 4167 2.33 3683 2.49 2948 2.42
SQAF 75% 5189 2.93 4757 3.12 4280 3.23 3716 3.25 1922 2.48
3500 HDAF 50% 6532 10.33 6397 10.75 6262 11.12 6128 11.38 5994 11.64 5860 11.90
HDAF 75% 9798 15.49 9596 16.13 9393 16.68 9192 17.07 8991 17.45 8790 17.84
HDAF-220 1750 HDAF 50% 4179 1.95 3828 2.28 3437 2.42 2960 2.41 1297 1.76
SQAF 50% 4901 3.57 4629 3.76 4335 3.88 3976 3.80 3507 3.53 2651 3.40
HDAF 75% 6268 2.93 5741 3.42 5256 3.63 4439 3.61 1945 2.63
SQAF 75% 7351 5.35 6943 5.63 6502 5.82 5964 5.70 5261 5.29 3976 5.10
HDAF-240 1750 HDAF 50% 5658 3.07 5275 3.50 4886 3.96 4420 3.90 3863 3.90 1995 3.01
SQAF 50% 6614 5.72 6326 6.02 6003 6.19 5680 6.35 5248 6.11 4759 5.72
HDAF 75% 8487 4.61 7913 5.25 7328 5.94 6630 5.84 1945 5.85 2993 4.51
SQAF 75% 9920 8.58 9488 9.03 9005 9.28 8519 9.53 7872 9.16 7139 8.58
HDAF-270 1750 HDAF 50% 8608 7.25 8279 7.70 7930 8.12 7524 8.47 7111 8.79 6627 8.76
SQAF 50% 9670 9.63 9316 10.01 8950 10.39 8520 10.75 8089 11.12 7563 11.14
HDAF 75% 12911 10.87 12419 11.54 11894 12.17 11286 12.71 10667 13.18 9941 13.14
SQAF 75% 14504 14.45 13974 15.02 13425 15.58 12779 16.13 12134 16.67 11345 16.71
HDAF-300 1750 HDAF 50% 11893 12.13 11528 12.74 11163 13.36 10744 13.89 10294 14.38 9843 14.86
SQAF 50% 13373 16.22 12981 16.74 12588 17.26 12152 17.77 11674 18.27 11195 18.78
HDAF 75% 17840 18.19 17292 19.11 16745 20.03 16116 20.84 15440 21.56 14764 22.28
SQAF 75% 20060 24.33 19471 25.11 18881 25.88 18288 26.65 17510 27.41 16793 28.16
HDAF-330 1750 HDAF 50% 15914 19.36 15513 20.18 15511 21.00 14710 21.81 14221 22.47 13725 23.12
SQAF 50% 17806 25.78 17374 26.47 16943 27.15 16511 27.84 16007 28.51 15481 29.18
HDAF 75% 23871 29.03 23269 30.26 22667 31.49 22064 32.72 21332 33.71 20588 34.67
SQAF 75% 26708 38.67 26061 39.70 25414 40.73 24767 41.76 24010 42.77 23222 43.76
HDAF-360 1750 HDAF 50% 20744 29.71 20306 30.77 19868 31.83 19430 32.89 18977 33.92 18436 34.76
SQAF 50% 24276 42.69 23798 43.62 23320 44.55 22843 45.48 22365 46.41 21802 47.32
HDAF 75% 31116 44.56 30459 46.15 29802 47.75 29144 49.34 27465 50.88 27654 52.14
SQAF 75% 36413 64.03 35697 65.42 34980 66.83 34264 68.22 33547 69.62 32702 70.98
The partial width fan ratings shown on this page and on pages 9, 10 and 11were derived from tests performed in accordance with AMCA Publication 210
and fan laws were applied to arrive at the data shown.
Performance shown is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances (accessories).
These performance ratings require a larger motor frame size even though the BHP is available in a smaller motor frame. See pages 23, 24 or 27 for the
minimum motor frame size for each fan model.

8
Sizes 120-160 have Class II wheels. Sizes 180-240 have
Class IIP wheels. Sizes 270-360 have Class III wheels.

7" SP 8" SP 9" SP 10" SP 11" SP 12" SP 13" SP 14" SP


CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

246 .89

369 1.34
481 1.42 Direct drive, partial width fans are available in 50% to 95%
836 1.70 501 1.53 widths, in 5 % increments, for your exact air flow requirements.
722 2.13 Consult your local Cincinnati Fan sales representative for your
1254 2.55 752 2.29 specific performance requirements if not shown here.

1700 3.11 1436 3.03


1649 3.48 1405 3.45 1108 3.35 752 3.16 232 2.75
2550 4.67 2154 4.55
2473 5.22 2108 5.18 1662 5.02 1128 4.73 348 4.12

2604 5.05 2377 5.04 2121 4.98 1792 4.81


2526 5.57 2312 5.62 2068 5.62 1781 5.55 1444 5.39 1053 5.14 569 4.72
3906 7.58 3566 7.56 3182 7.46 2688 7.21
3789 8.36 3469 8.43 3101 8.43 2671 8.32 2166 8.09 1579 7.70 854 7.09

4174 7.91 4031 8.10 3889 8.29 3729 8.41 3532 8.37 3334 8.33 3087 8.22 2774 8.01
4780 10.61 4648 10.79 4505 10.91 4339 10.92 4174 10.93 4006 10.95 3828 10.97 3649 10.99
6260 11.86 6047 12.14 5833 12.43 5594 12.61 5297 12.55 5000 12.49 4630 12.32 4160 12.02
7169 15.91 6971 16.18 6758 16.37 6509 16.38 6260 16.40 6009 16.42 5741 16.45 5474 16.48

5713 12.15 5557 12.40 5400 12.65 5244 12.89 5088 13.14 4910 13.29 4694 13.23 4477 13.18
8569 18.22 8335 18.59 8100 18.97 7866 19.34 7632 19.71 7365 19.93 7040 19.85 6715 19.76

393 1.87

590 2.81

3795 5.59 2348 4.62

5692 8.38 3522 6.92


5843 8.46 2674 5.75
7006 11.05 6406 10.87 5475 10.30 2583 7.53
8765 12.69 4011 8.62
10509 16.58 9608 16.31 8213 15.45 3874 11.30
9309 14.85 8771 14.81 7494 13.95 2844 8.81
10644 18.96 10024 18.83 9389 18.67 8721 18.42 7761 17.75 3377 12.36
13964 22.28 13157 22.22 11241 20.92 4265 13.21
15965 28.43 15036 28.25 14084 28.00 13082 27.63 11641 26.62 5066 18.54
13230 23.76 12669 23.94 12077 23.89 11399 23.72 9798 22.31 4520 15.18
14956 29.84 14402 30.36 13722 30.20 13042 30.03 12333 29.78 11599 29.46 10865 29.13 6089 22.06
19844 35.64 19003 35.90 18116 35.83 17098 35.58 14697 33.46 6780 22.77
22433 44.76 21603 45.54 20583 45.29 19563 45.05 18500 44.67 17399 44.18 16298 43.69 9133 33.08
17895 35.60 17354 36.44 16784 37.02 16138 36.95 15492 36.89 14625 36.47 12879 34.63 7523 26.34
21220 48.23 20638 49.13 20056 50.04 19403 50.48 18650 50.25 17897 50.03 17134 49.77 16322 49.33
26843 53.39 26031 54.65 25175 55.52 24206 55.43 23238 55.34 21937 54.70 19319 51.94 11284 39.51
31829 72.34 30957 73.70 30084 75.05 29105 75.71 27975 75.38 26846 75.05 25701 74.66 24482 73.99
These performance ratings require a larger motor frame size even though the BHP is available in a smaller motor frame. See pages 23, 24 or 27
for the minimum motor frame size for each fan model.
These performance ratings not available in Arrangement 4HM because motor exceeds frame size limits. See page 24.

9
HDAF-120 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 12.25" Size - 9.38" x 13.69" Size - 13.25" All wheels are Class II, HDAF type.
Area - .85 Sq. Ft. I.D. Area - .93 Sq.Ft. I.D.
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2.
3
VOLUME O.V. 0" SP 1/4" SP 1/2" SP /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
400 447 444 .01 813 .03 1073 .06 1288 .10 1474 .14 1790 .24 2058 .35
600 670 665 .01 953 .05 1170 .08 1360 .13 1531 .17 1831 .28 2092 .41
800 894 887 .03 1125 .08 1310 .12 1475 .17 1627 .22 1901 .34 2147 .47
1000 1117 1109 .07 1312 .12 1474 .17 1620 .23 1755 .29 2004 .42 2231 .56

1200 1341 1331 .12 1508 .18 1653 .24 1784 .31 1906 .37 2132 .52 2341 .67
1400 1564 1553 .19 1710 .26 1841 .33 1961 .40 2073 .48 2280 .64 2472 .81
1600 1787 1774 .28 1915 .36 2036 .44 2146 .52 2249 .61 2441 .78 2620 .97
1800 2011 1996 .40 2124 .49 2235 .58 2338 .67 2434 .77 2613 .96 2779 1.16

2000 2234 2218 .54 2335 .65 2438 .75 2534 .85 2624 .95 2792 1.16 2948 1.38
2200 2458 2440 .72 2547 .84 2644 .95 2733 1.06 2818 1.17 2976 1.40 3125 1.64
2400 2681 2662 .94 2761 1.06 2851 1.19 2936 1.31 3016 1.43 3166 1.68 3306 1.93
2600 2904 2883 1.20 2976 1.33 3061 1.46 3140 1.59 3216 1.73 3359 1.99 3493 2.26

2800 3128 3105 1.49 3191 1.64 3272 1.78 3347 1.92 3419 2.06 3555 2.35 3683 2.64
3000 3351 3327 1.84 3408 1.99 3484 2.14 3555 2.30 3624 2.45 3754 2.75 3876 3.06
3200 3575 3549 2.23 3625 2.39 3697 2.56 3765 2.72 3830 2.88 3955 3.21 4072 3.54
3400 3798 3771 2.68 3843 2.85 3911 3.02 3976 3.20 4038 3.37 4158 3.71

VOLUME O.V. 21/2" SP 3" SP 31/2" SP 4" SP 41/2" SP 5" SP 51/2" SP


CFM FPM
400 447 2295 .48 2509 .61 2706 .76 2889 .91 3060 1.07 3223 1.24 3377 1.42
600 670 2325 .54 2537 .69 2733 .84 2916 1.01 3088 1.18 3250 1.37 3405 1.56
800 894 2370 .62 2576 .77 2768 .94 2948 1.12 3118 1.30 3279 1.50 3433 1.70
1000 1117 2441 .72 2637 .88 2821 1.06 2995 1.24 3160 1.44 3318 1.64 3470 1.85

1200 1341 2536 .84 2720 1.01 2895 1.20 3061 1.39 3220 1.60 3373 1.81 3520 2.03
1400 1564 2653 .98 2826 1.17 2990 1.37 3148 1.57 3299 1.79 3446 2.01 3587 2.24
1600 1787 2789 1.16 2950 1.36 3104 1.57 3253 1.79 3397 2.01 3536 2.24 3671 2.48
1800 2011 2938 1.36 3089 1.58 3234 1.80 3375 2.03 3511 2.27 3644 2.51 3772 2.76

2000 2234 3097 1.60 3240 1.83 3377 2.07 3510 2.31 3640 2.56 3765 2.82 3888 3.08
2200 2458 3265 1.88 3400 2.12 3531 2.37 3657 2.63 3780 2.89 3899 3.16 4016 3.44
2400 2681 3440 2.19 3568 2.45 3692 2.71 3813 2.99 3930 3.27 4044 3.55 4155 3.84
2600 2904 3620 2.54 3743 2.82 3861 3.10 3976 3.39 4088 3.68

2800 3128 3805 2.93 3922 3.23 4035 3.53 4145 3.84
3000 3351 3993 3.37 4105 3.69
3200 3575 4185 3.87

VOLUME O.V. 6" SP 61/2" SP 7" SP 71/2" SP 8" SP


CFM FPM
400 447 3524 1.61 3665 1.80 3801 2.00 3932 2.20 4059 2.41
600 670 3553 1.75 3695 1.96 3831 2.17 3963 2.39 4090 2.61
800 894 3581 1.90 3722 2.12 3858 2.34 3990 2.57 4117 2.81
1000 1117 3615 2.07 3754 2.30 3889 2.53 4020 2.77 4146 3.01

1200 1341 3661 2.26 3798 2.49 3930 2.74 4059 2.99 4183 3.24
1400 1564 3724 2.48 3856 2.72 3985 2.97 4110 3.23
1600 1787 3803 2.73 3930 2.99 4054 3.25 4176 3.52
1800 2011 3898 3.02 4020 3.29 4140 3.56

2000 2234 4008 3.35 4125 3.63


2200 2458 4131 3.72
Performance is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the
effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses.

10
HDAF-130 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 13.50" Size - 10.38" x 15.19" Size - 14.63" All wheels are Class II, HDAF type.
Area - 1.05 Sq. Ft. I.D. Area -1.14 Sq.Ft. I.D.
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2.
3
VOLUME O.V. 0" SP / " SP
1 4 / " SP
1 2 /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
500 455 414 .01 744 .03 978 .07 1172 .12 1340 .17 1626 .29 1869 .43
750 683 622 .02 878 .06 1072 .11 1242 .16 1395 .22 1666 .35 1901 .50
1000 910 829 .05 1040 .10 1205 .15 1353 .21 1488 .28 1735 .42 1956 .59
1250 1138 1036 .09 1216 .15 1361 .22 1491 .29 1612 .36 1834 .52 2037 .70

1500 1365 1243 .16 1400 .23 1530 .31 1646 .39 1755 .47 1957 .65 2144 .84
1750 1593 1450 .25 1589 .34 1707 .43 1813 .52 1913 .61 2098 .81 2270 1.02
2000 1820 1658 .37 1782 .47 1890 .57 1988 .68 2080 .78 2251 1.00 2410 1.23
2250 2048 1865 .53 1978 .64 2077 .75 2168 .87 2253 .99 2413 1.23 2562 1.47

2500 2275 2072 .72 2175 .85 2267 .98 2352 1.10 2432 1.23 2582 1.49 2721 1.76
2750 2503 2279 .96 2374 1.10 2459 1.24 2539 1.38 2614 1.52 2756 1.81 2888 2.10
3000 2730 2486 1.25 2574 1.40 2654 1.55 2729 1.70 2800 1.86 2934 2.17 3059 2.48
3250 2958 2694 1.59 2775 1.75 2850 1.92 2921 2.08 2988 2.25 3115 2.58 3235 2.92

3500 3185 2901 1.98 2977 2.16 3048 2.34 3115 2.51 3179 2.69 3299 3.05 3413 3.41
3750 3413 3108 2.44 3179 2.63 3246 2.82 3310 3.01 3371 3.20 3486 3.58 3595 3.96
4000 3641 3315 2.96 3382 3.16 3446 3.36 3506 3.57 3564 3.77 3675 4.18 3779 4.58
4250 3868 3522 3.55 3586 3.76 3646 3.98 3704 4.20 3759 4.41

4500 4096 3730 4.21 3790 4.44

VOLUME O.V. 21/2" SP 3" SP 31/2" SP 4" SP 41/2" SP 5" SP 51/2" SP


CFM FPM
500 455 2084 .58 2278 .75 2457 .93 2623 1.11 2779 1.31 2926 1.52 3066 1.74
750 683 2112 .66 2305 .84 2482 1.03 2648 1.24 2804 1.45 2952 1.67 3092 1.90
1000 910 2157 .76 2343 .95 2517 1.16 2679 1.37 2833 1.60 2979 1.84 3119 2.08
1250 1138 2226 .89 2402 1.09 2568 1.31 2725 1.54 2875 1.77 3017 2.02 3154 2.28

1500 1365 2319 1.05 2484 1.26 2641 1.49 2790 1.73 2934 1.98 3071 2.24 3203 2.51
1750 1593 2432 1.24 2586 1.47 2733 1.71 2875 1.96 3011 2.22 3142 2.50 3269 2.78
2000 1820 2561 1.46 2705 1.71 2843 1.97 2977 2.23 3106 2.51 3230 2.80 3352 3.09
2250 2048 2703 1.73 2838 1.99 2968 2.27 3094 2.55 3216 2.84 3334 3.14 3450 3.45

2500 2275 2854 2.04 2982 2.32 3104 2.61 3223 2.92 3339 3.22 3451 3.54 3561 3.86
2750 2503 3013 2.39 3134 2.70 3250 3.01 3363 3.33 3473 3.65 3580 3.99 3684 4.33
3000 2730 3178 2.80 3293 3.12 3403 3.46 3511 3.79 3615 4.14 3717 4.49 3817 4.85
3250 2958 3348 3.26 3457 3.60 3563 3.96 3665 4.31 3765 4.68

3500 3185 3522 3.77 3627 4.14 3728 4.52 3826 4.90
3750 3413 3699 4.35 3799 4.74

VOLUME O.V. 6" SP 61/2" SP 7" SP 71/2" SP 8" SP 81/2" SP


CFM FPM
500 455 3200 1.96 3328 2.20 3451 2344 3570 2.69 3685 2.95 3796 3.21
750 683 3226 2.15 3355 2.40 3479 2.65 3598 2.92 3714 3.19 3826 3.47
1000 910 3252 2.34 3380 2.60 3504 2.87 3623 3.15 3739 3.44
1250 1138 3285 2.55 3412 2.82 3534 3.11 3652 3.40 3767 3.70

1500 1365 3331 2.79 3455 3.08 3574 3.37 3690 3.68 3803 3.99
1750 1593 3392 3.07 3512 3.37 3628 3.68 3740 3.99
2000 1820 3470 3.40 3584 3.71 3696 4.03 3805 4.36
2250 2048 3562 3.77 3672 4.10 3779 4.43

2500 2275 3668 4.20 3773 4.54


2750 2503 3786 4.68
Performance is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the
effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses.

11
HDAF-150 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 15.00" Size - 11.38" x 16.75" Size - 16.13" All wheels are Class II, HDAF type.
Area - 1.28 Sq. Ft. I.D. Area -1.39 Sq.Ft. I.D.
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2.
3
VOLUME O.V. 0" SP 1/4" SP 1/2" SP /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
1000 753 599 .03 808 .08 969 .13 1107 .20 1233 .26 1461 .42 1666 .60
1250 941 749 .05 925 .11 1071 .18 1197 .25 1311 .33 1517 .49 1705 .68
1500 1129 898 .09 1049 .16 1182 .24 1298 .32 1404 .40 1595 .59 1768 .79
1750 1318 1048 .15 1179 .23 1300 .32 1408 .41 1507 .50 1685 .70 1847 .91

2000 1506 1198 .22 1313 .31 1423 .41 1524 .51 1617 .62 1785 .83 1938 1.06
2250 1694 1347 .31 1450 .41 1550 .52 1644 .64 1732 .75 1892 .99 2037 1.24
2500 1882 1497 .43 1590 .54 1681 .66 1768 .78 1851 .91 2003 1.17 2142 1.44
2750 2071 1647 .57 1731 .69 1815 .82 1896 .96 1973 1.09 2118 1.37 2251 1.66

3000 2259 1796 .74 1873 .87 1951 1.01 2026 1.16 2099 1.31 2237 1.61 2364 1.92
3250 2447 1946 .94 2017 1.08 2088 1.24 2159 1.39 2227 1.55 2358 1.87 2481 2.21
3500 2635 2096 1.17 2162 1.33 2228 1.49 2294 1.66 2358 1.83 2483 2.17 2600 2.53
3750 2824 2246 1.44 2307 1.61 2369 1.78 2430 1.96 2491 2.14 2609 2.51 2722 2.88

4000 3012 2395 1.74 2453 1.92 2511 2.11 2569 2.30 2626 2.49 2738 2.88 2846 3.28
4250 3200 2545 2.09 2599 2.28 2654 2.48 2708 2.68 2762 2.88 2869 3.29 2972 3.71
4500 3388 2695 2.48 2746 2.69 2797 2.89 2849 3.10 2900 3.32 3002 3.75 3100 4.19
4750 3577 2844 2.92 2893 3.13 2941 3.35 2990 3.57 3039 3.80 3136 4.25 3230 4.72

5000 3765 2994 3.40 3040 3.63 3086 3.86 3133 4.09 3179 4.33 3271 4.80 3362 5.29
5250 3953 3144 3.94 3187 4.18 3231 4.42 3276 4.66 3320 4.91 3408 5.41 3495 5.91
5500 4141 3293 4.53 3335 4.78 3377 5.03 3419 5.28 3462 5.54
5750 4330 3443 5.18 3483 5.44

VOLUME O.V. 21/2" SP 3" SP 31/2" SP 4" SP 41/2" SP 5" SP 51/2" SP


CFM FPM
1000 753 1853 .79 2027 1.00
1250 941 1879 .89 2043 1.11 2197 1.34 2344 1.59 2483 1.85
1500 1129 1929 1.00 2082 1.23 2227 1.48 2366 1.74 2499 2.01 2627 2.30 2750 2.59
1750 1318 1998 1.14 2141 1.39 2277 1.64 2408 1.91 2534 2.20 2655 2.49 2773 2.80

2000 1506 2081 1.31 2215 1.56 2343 1.83 2467 2.12 2586 2.41 2701 2.72 2813 3.03
2250 1694 2172 1.50 2300 1.77 2422 2.05 2539 2.35 2652 2.66 2761 2.97 2868 3.30
2500 1882 2271 1.71 2393 2.00 2510 2.30 2621 2.61 2729 2.93 2834 3.26 2935 3.60
2750 2071 2376 1.96 2493 2.27 2604 2.58 2712 2.91 2815 3.24 2915 3.59 3013 3.94

3000 2259 2484 2.24 2597 2.56 2705 2.89 2808 3.24 2907 3.59 3004 3.95 3098 4.32
3250 2447 2596 2.54 2705 2.89 2809 3.24 2909 3.60 3005 3.97 3098 4.35 3189 4.73
3500 2635 2711 2.88 2817 3.25 2917 3.62 3014 4.00 3107 4.39 3198 4.78 3285 5.19
3750 2824 2829 3.26 2931 3.65 3028 4.04 3122 4.44 3213 4.85 3301 5.26 3386 5.68

4000 3012 2949 3.68 3048 4.09 3142 4.50 3234 4.92 3322 5.35 3407 5.78 3490 6.22
4250 3200 3071 4.14 3167 4.57 3259 5.00 3347 5.44 3433 5.89
4500 3388 3196 4.64 3288 5.09 3377 5.55 3463 6.01
4750 3577 3322 5.18 3411 5.66 3498 6.14
5000 3765 3450 5.78

VOLUME O.V. 6" SP 61/2" SP 7" SP 71/2" SP 8" SP 81/2" SP 9" SP


CFM FPM
1500 1129 2869 2.90 2985 3.21
1750 1318 2887 3.11 2998 3.44 3106 3.78 3211 4.13 3314 4.48 3414 4.85 3512 5.22

2000 1506 2922 3.36 3028 3.70 3132 4.05 3233 4.40 3332 4.77 3428 5.14
2250 1694 2972 3.64 3073 3.99 3172 4.35 3269 4.71 3364 5.09 3457 5.48
2500 1882 3035 3.95 3131 4.31 3226 4.68 3319 5.06 3410 5.45 3500 5.85
2750 2071 3108 4.31 3201 4.68 3291 5.06 3381 5.45 3468 5.85

3000 2259 3189 4.70 3279 5.08 3366 5.48 3452 5.88
3250 2447 3277 5.12 3364 5.53 3448 5.94
3500 2635 3371 5.59 3454 6.01
3750 2824 3469 6.11
Performance is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the
effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses.
12
HDAF-160 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 16.50" Size - 12.50" x 18.38" Size - 18.00" All wheels are Class II, HDAF type.
Area - 1.54 Sq. Ft. I.D. Area -1.73 Sq.Ft. I.D.
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2.
3
VOLUME O.V. 0" SP / " SP
1 4 / " SP
1 2 /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
2000 1250 900 .15 1026 .24 1140 .34 1241 .45 1333 .56 1499 .79 1650 1.04
2300 1437 1035 .23 1145 .33 1249 .45 1343 .57 1430 .69 1586 .94 1728 1.21
2600 1625 1170 .33 1268 .45 1362 .57 1450 .71 1531 .84 1680 1.12 1815 1.41
2900 1812 1305 .45 1392 .59 1479 .73 1560 .87 1637 1.02 1779 1.32 1907 1.63

3200 1999 1440 .61 1519 .76 1598 .91 1674 1.07 1747 1.23 1881 1.55 2004 1.89
3500 2187 1575 .80 1647 .96 1720 1.12 1791 1.29 1859 1.47 1987 1.82 2105 2.18
3800 2374 1710 1.02 1776 1.19 1843 1.37 1909 1.56 1974 1.74 2095 2.12 2209 2.51
4100 2562 1845 1.28 1906 1.47 1969 1.66 2030 1.86 2091 2.06 2206 2.46 2315 2.88

4400 2749 1980 1.58 2037 1.78 2095 1.99 2153 2.20 2210 2.41 2320 2.84 2424 3.29
4700 2937 2114 1.93 2168 2.14 2223 2.36 2277 2.59 2330 2.81 2435 3.27 2535 3.74
5000 3124 2249 2.33 2300 2.55 2351 2.78 2402 3.02 2453 3.26 2552 3.74 2648 4.24
5300 3312 2384 2.77 2432 3.01 2480 3.25 2528 3.50 2576 3.75 2671 4.27 2762 4.79

5600 3499 2519 3.27 2565 3.52 2610 3.78 2656 4.04 2701 4.30 2791 4.84 2879 5.39
5900 3686 2654 3.82 2697 4.09 2740 4.36 2784 4.63 2827 4.91 2913 5.47 2997 6.05
6200 3874 2789 4.43 2830 4.71 2871 5.00 2912 5.28 2953 5.58 3035 6.17 3116 6.77
6500 4061 2924 5.11 2963 5.40 3002 5.70 3041 6.00 3081 6.30 3159 6.92

6800 4249 3059 5.85 3096 6.16 3134 6.47 3171 6.78
7100 4436 3194 6.66

VOLUME O.V. 21/2" SP 3" SP 31/2" SP 4" SP 41/2" SP 5" SP 51/2" SP


CFM FPM
2000 1250 1791 1.31 1924 1.60 2050 1.91 2172 2.23 2289 2.57 2402 2.92 2511 3.28
2300 1437 1861 1.50 1986 1.80 2105 2.12 2220 2.46 2330 2.81 2437 3.17 2541 3.55
2600 1625 1940 1.71 2059 2.04 2172 2.37 2280 2.72 2385 3.09 2487 3.47 2586 3.86
2900 1812 2027 1.96 2140 2.30 2248 2.66 2351 3.02 2451 3.40 2548 3.80 2642 4.20

3200 1999 2119 2.24 2227 2.60 2331 2.98 2430 3.36 2525 3.76 2618 4.17 2708 4.59
3500 2187 2215 2.56 2320 2.94 2419 3.33 2514 3.74 2606 4.16 2696 4.58 2782 5.02
3800 2374 2315 2.91 2416 3.32 2512 3.73 2604 4.16 2693 4.60 2779 5.04 2862 5.50
4100 2562 2418 3.30 2515 3.73 2608 4.17 2697 4.62 2783 5.08 2866 5.55 2947 6.02

4400 2749 2523 3.73 2617 4.19 2707 4.65 2793 5.13 2877 5.61 2958 6.10 3036 6.59
4700 2937 2630 4.21 2721 4.69 2808 5.18 2893 5.68 2974 6.18 3052 6.69 3129 7.21
5000 3124 2740 4.74 2828 5.25 2912 5.76 2994 6.28 3073 6.81 3149 7.34
5300 3312 2851 5.31 2936 5.85 3018 6.39 3098 6.93 3174 7.49

5600 3499 2964 5.94 3046 6.50 3126 7.07


5900 3686 3079 6.63 3158 7.21
6200 3874 3195 7.37

VOLUME O.V. 6" SP 61/2" SP 7" SP 71/2" SP 8" SP 81/2" SP


CFM FPM
2000 1250 2616 3.66 2719 4.05 2819 4.46 2915 4.87
2300 1437 2642 3.94 2740 4.35 2836 4.76 2929 5.19 3021 5.63 3110 6.08
2600 1625 2682 4.26 2776 4.68 2867 5.11 2957 5.55 3045 6.00 3131 6.46
2900 1812 2734 4.62 2824 5.05 2911 5.49 2997 5.95 3082 6.41 3164 6.88

3200 1999 2796 5.03 2882 5.47 2966 5.93 3049 6.39 3129 6.87
3500 2187 2867 5.47 2949 5.93 3030 6.41 3109 6.89 3187 7.38
3800 2374 2944 5.97 3023 6.45 3101 6.93 3178 7.43
4100 2562 3026 6.51 3103 7.01 3178 7.51

4400 2749 3113 7.10 3187 7.62


Performance is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the
effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses.

13
HDAF-180 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 18.25" Size - 13.88" x 20.38" Size - 20.00" All wheels are HDAF type.
Area - 1.90 Sq. Ft. I.D. Area - 2.13 Sq.Ft. I.D. Class II = light face above Class IIP
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class IIP = bold face below Class II
VOLUME O.V. 0" SP 1/2" SP 1" SP 11/2" SP 2" SP 21/2" SP 3" SP 31/2" SP
CFM FPM
1500 789 518 .04 745 .16 938 .31
1800 947 622 .07 816 .21 984 .37 1143 .56
2100 1105 725 .11 899 .27 1049 .45 1189 .64 1323 .87
2400 1263 829 .17 984 .35 1116 .55 1247 .75 1370 .98 1488 1.23
2700 1421 933 .24 1071 .44 1196 .65 1313 .88 1424 1.12 1534 1.38 1640 1.66
3000 1578 1036 .33 1164 .55 1279 .78 1382 1.03 1490 1.29 1588 1.55 1687 1.84 1785 2.15
3300 1736 1140 .43 1258 .68 1364 .93 1463 1.20 1557 1.48 1654 1.76 1743 2.05 1831 2.36
3600 1894 1244 .56 1354 .83 1451 1.09 1546 1.38 1632 1.69 1721 1.99 1808 2.30 1890 2.62
3900 2052 1347 .71 1450 1.01 1540 1.29 1630 1.59 1714 1.92 1791 2.25 1875 2.58 1956 2.91
4200 2210 1451 .89 1547 1.22 1633 1.51 1716 1.83 1797 2.17 1872 2.52 1943 2.88 2023 3.24
4500 2368 1555 1.10 1645 1.45 1727 1.77 1804 2.09 1882 2.45 1955 2.82 2023 3.20 2091 3.59
4800 2526 1658 1.33 1744 1.71 1821 2.05 1893 2.39 1968 2.76 2038 3.15 2105 3.55 2169 3.95
5100 2684 1762 1.60 1843 2.00 1917 2.37 1986 2.73 2055 3.11 2123 3.51 2189 3.93 2251 4.35
5400 2842 1865 1.90 1942 2.32 2013 2.72 2080 3.10 2143 3.48 2209 3.91 2273 4.34 2334 4.79
5700 3000 1969 2.23 2042 2.68 2110 3.11 2174 3.50 2235 3.91 2297 4.34 2358 4.79 2418 5.25
6000 3157 2073 2.60 2142 3.07 2208 3.53 2269 3.95 2328 4.37 2384 4.81 2445 5.28 2503 5.76
6300 3315 2176 3.01 2243 3.50 2306 4.00 2365 4.44 2422 4.88 2476 5.33 2532 5.80 2589 6.30
6600 3473 2280 3.46 2344 3.98 2404 4.50 2461 4.97 2516 5.43 2569 5.90 2620 6.37 2675 6.89
6900 3631 2384 3.96 2445 4.49 2503 5.04 2558 5.54 2611 6.02 2663 6.51 2712 7.00 2763 7.52
7200 3789 2487 4.50 2546 5.05 2602 5.63 2656 6.16 2707 6.66 2757 7.17 2805 7.68 2852 8.20
7500 3947 2591 5.08 2647 5.66 2701 6.26 2753 6.84 2803 7.35 2852 7.88 2898 8.41 2944 8.94
7800 4105 2695 5.72 2749 6.32 2801 6.94 2851 7.56 2900 8.10 2947 8.64 2993 9.19 3037 9.74
8100 4263 2798 6.40 2851 7.03 2901 7.67 2950 8.31 2997 8.89 3043 9.45 3087 10.02 3130 10.59
8400 4421 2902 7.14 2952 7.79 3001 8.45 3049 9.12 3094 9.74 3139 10.32 3182 10.91 3224 11.50
8700 4578 3006 7.93 3054 8.61 3102 9.29 3148 9.98 3192 10.65 3236 11.25 3278 11.85 3319 12.46
9000 4736 3109 8.78 3156 9.48 3202 10.18 3247 10.90 3290 11.61 3333 12.23 3374 12.86 3414 13.49
9300 4894 3213 9.69 3259 10.41 3303 11.14 3346 11.87 3389 12.62 3430 13.28 3470 13.92 3509 14.57
9600 5052 3316 10.66 3361 11.40 3404 12.15 3446 12.91 3487 13.68 3528 14.39 3567 15.05 3605 15.72

VOLUME O.V. 4" SP 41/2" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP
CFM FPM
3000 1578 1876 2.47
3300 1736 1922 2.70 2008 3.05 2089 3.41
3600 1894 1969 2.95 2054 3.32 2135 3.69 2287 4.46
3900 2052 2032 3.26 2104 3.61 2182 3.99 2332 4.80 2472 5.64
4200 2210 2098 3.60 2169 3.97 2237 4.34 2379 5.16 2517 6.03 2647 6.93
4500 2368 2164 3.97 2235 4.35 2302 4.75 2429 5.55 2564 6.45 2693 7.38 2814 8.34
4800 2526 2233 4.37 2302 4.77 2368 5.18 2493 6.02 2611 6.89 2739 7.86 2860 8.86 2975 9.88
5100 2684 2310 4.79 2370 5.22 2435 5.65 2559 6.53 2675 7.43 2786 8.36 2907 9.39 3021 10.45
5400 2842 2392 5.24 2448 5.69 2504 6.16 2626 7.08 2740 8.01 2848 8.97 2953 9.96 3068 11.05
5700 3000 2475 5.72 2530 6.20 2583 6.68 2694 7.66 2807 8.63 2914 9.62 3015 10.63 3114 11.68
6000 3157 2558 6.25 2612 6.74 2664 7.24 2764 8.27 2874 9.29 2980 10.32 3080 11.37 3176 12.43
6300 3315 2643 6.81 2696 7.32 2747 7.85 2844 8.91 2942 9.99 3047 11.06 3146 12.14 3242 13.24
6600 3473 2729 7.42 2780 7.95 2830 8.49 2926 9.59 3017 10.71 3114 11.84 3213 12.96 3307 14.10
6900 3631 2815 8.06 2865 8.62 2914 9.17 3008 10.31 3098 11.47 3184 12.66 3281 13.82 3374 15.00
7200 3789 2902 8.76 2951 9.33 2999 9.90 3092 11.08 3180 12.28 3264 13.50 3349 14.73 3441 15.95
7500 3947 2990 9.50 3038 10.09 3085 10.68 3176 11.89 3263 13.13 3346 14.39 3425 15.67 3510 16.95
7800 4105 3080 10.30 3126 10.89 3172 11.51 3261 12.76 3346 14.03 3428 15.33 3506 16.64 3582 17.98
8100 4263 3173 11.17 3214 11.75 3259 12.39 3347 13.67 3430 14.99 3511 16.32 3588 17.67 3663 19.05
8400 4421 3266 12.10 3306 12.70 3347 13.32 3433 14.64 3515 15.99 3594 17.36 3671 18.75 3744 20.16
8700 4578 3359 13.08 3399 13.70 3437 14.32 3520 15.67 3601 17.05 3678 18.46 3754 19.89
9000 4736 3453 14.12 3492 14.76 3530 15.40 3607 16.75 3687 18.17 3763 19.62
9300 4894 3548 15.22 3586 15.88 3623 16.54 3695 17.89 3774 19.35
9600 5052 3643 16.39 3680 17.07 3716 17.75 3787 19.12

VOLUME O.V. 11" SP 12" SP 13" SP 14" SP 15" SP 16" SP


CFM FPM
5000 2631 3115 11.33
5300 2789 3161 11.95 3265 13.08 3366 14.23
5600 2947 3207 12.61 3311 13.77 3412 14.95 3508 16.16
5900 3105 3254 13.29 3358 14.49 3458 15.71 3554 16.95 3647 18.21 3737 19.49
6200 3263 3311 14.08 3405 15.24 3504 16.50 3600 17.77 3693 19.07 3783 20.38
6500 3421 3376 14.95 3464 16.11 3551 17.31 3647 18.63 3739 19.96
6800 3578 3442 15.88 3529 17.08 3613 18.29 3694 19.52 3786 20.88
7100 3736 3508 16.85 3595 18.08 3678 19.33 3759 20.60
7400 3894 3575 17.87 3661 19.14 3744 20.43 NOTE: See pages 25, 28 or 29 for minimum
7700 4052 3643 18.94 3728 20.25 3810 21.57
8000 4210 3711 20.06 3795 21.41 motor frame sizes regardless of BHP.
8300 4368 3789 21.21

Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

14
HDAF-200 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 20.00" Size - 15.25" x 22.38" Size - 22.00" All wheels are HDAF type.
Area - 2.30 Sq. Ft. I.D. Area - 2.58 Sq.Ft. I.D. Class II = light face above Class IIP
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class IIP = bold face below Class II
VOLUME O.V. 0" SP 1/2" SP 1" SP 11/2" SP 2" SP 21/2" SP 3" SP 31/2" SP
CFM FPM
1500 652 394 .03 632 .15
1900 826 499 .06 696 .21 867 .39
2300 1000 604 .10 773 .28 920 .48 1059 .71
2700 1173 709 .16 858 .37 987 .59 1108 .83 1228 1.11
3100 1347 814 .25 946 .48 1062 .73 1174 1.00 1276 1.27 1383 1.59 1480 1.92
3500 1521 919 .36 1038 .62 1145 .89 1242 1.19 1342 1.49 1432 1.80 1527 2.15 1616 2.52
3900 1695 1024 .50 1133 .79 1231 1.08 1322 1.40 1410 1.73 1498 2.07 1580 2.42 1663 2.79
4300 1869 1129 .66 1229 .99 1319 1.30 1406 1.65 1484 2.01 1566 2.38 1646 2.75 1721 3.13
4700 2043 1234 .87 1327 1.23 1409 1.56 1491 1.93 1567 2.31 1638 2.71 1714 3.11 1787 3.52
5100 2217 1339 1.11 1426 1.50 1503 1.86 1579 2.25 1652 2.66 1720 3.08 1784 3.52 1855 3.95
5500 2391 1444 1.39 1525 1.82 1598 2.21 1667 2.60 1738 3.04 1804 3.49 1866 3.95 1925 4.42
5900 2565 1549 1.72 1625 2.18 1695 2.60 1759 3.02 1825 3.47 1889 3.94 1950 4.43 2007 4.92
6300 2739 1654 2.09 1726 2.58 1792 3.04 1854 3.48 1914 3.95 1976 4.44 2034 4.95 2091 5.47
6700 2913 1759 2.51 1827 3.04 1890 3.54 1949 4.00 2005 4.48 2063 5.00 2121 5.53 2175 6.08
7100 3086 1864 2.99 1928 3.54 1988 4.09 2045 4.58 2099 5.08 2152 5.60 2208 6.16 2261 6.73
7500 3260 1969 3.52 2030 4.11 2087 4.70 2142 5.22 2194 5.74 2244 6.28 2296 6.85 2348 7.45
7900 3434 2074 4.12 2132 4.73 2187 5.36 2240 5.92 2290 6.47 2338 7.03 2385 7.60 2435 8.22
8300 3608 2179 4.78 2234 5.42 2287 6.08 2338 6.68 2386 7.26 2433 7.84 2478 8.44 2524 9.06
8700 3782 2284 5.50 2337 6.17 2388 6.86 2436 7.52 2483 8.12 2528 8.73 2572 9.35 2615 9.97
9100 3956 2389 6.29 2439 7.00 2488 7.72 2535 8.43 2581 9.05 2624 9.69 2667 10.33 2708 10.98
9500 4130 2494 7.16 2542 7.90 2589 8.65 2635 9.41 2679 10.07 2721 10.73 2762 11.39 2802 12.07
9900 4304 2599 8.10 2645 8.87 2691 9.65 2735 10.44 2777 11.16 2818 11.84 2858 12.53 2897 13.23
10300 4478 2704 9.13 2749 9.92 2792 10.73 2835 11.55 2876 12.33 2916 13.04 2955 13.76 2993 14.48
10700 4652 2809 10.23 2852 11.06 2894 11.90 2935 12.75 2975 13.59 3014 14.33 3052 15.07 3089 15.82
11100 4826 2914 11.42 2956 12.28 2996 13.15 3036 14.03 3075 14.92 3113 15.70 3150 16.47 3186 17.24
11500 5000 3019 12.70 3059 13.59 3099 14.49 3137 15.40 3175 16.32 3212 17.17 3247 17.96 3283 18.76

VOLUME O.V. 4" SP 41/2" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP
CFM FPM
3500 1521 1700 2.89
3900 1695 1747 3.20 1825 3.61 1899 4.03
4300 1869 1794 3.52 1872 3.96 1946 4.41 2084 5.33
4700 2043 1857 3.93 1923 4.35 1993 4.81 2130 5.78 2257 6.79
5100 2217 1923 4.39 1988 4.83 2050 5.29 2177 6.26 2304 7.32 2422 8.41
5500 2391 1991 4.89 2055 5.36 2117 5.84 2232 6.81 2351 7.88 2468 9.02 2579 10.18
5900 2565 2062 5.43 2124 5.93 2184 6.43 2298 7.46 2404 8.51 2515 9.66 2626 10.88 2730 12.12
6300 2739 2144 6.00 2196 6.54 2253 7.08 2365 8.16 2470 9.26 2569 10.38 2673 11.61 2777 12.90
6700 2913 2228 6.63 2278 7.20 2327 7.77 2433 8.91 2537 10.06 2634 11.23 2728 12.43 2825 13.72
7100 3086 2312 7.31 2361 7.90 2409 8.50 2502 9.71 2604 10.92 2701 12.14 2793 13.39 2881 14.65
7500 3260 2398 8.05 2446 8.66 2492 9.29 2582 10.56 2673 11.84 2769 13.11 2860 14.41 2947 15.72
7900 3434 2484 8.85 2531 9.49 2577 10.14 2664 11.45 2748 12.80 2837 14.14 2927 15.49 3014 16.86
8300 3608 2571 9.71 2618 10.38 2662 11.05 2748 12.42 2830 13.81 2908 15.24 2996 16.64 3081 18.06
8700 3782 2660 10.64 2705 11.33 2748 12.03 2833 13.45 2913 14.89 2989 16.37 3065 17.86 3149 19.33
9100 3956 2749 11.64 2793 12.36 2836 13.08 2918 14.55 2997 16.04 3072 17.56 3145 19.11 3219 20.67
9500 4130 2842 12.75 2882 13.46 2924 14.20 3004 15.72 3081 17.27 3156 18.84 3227 20.44 3296 22.06
9900 4304 2936 13.94 2973 14.65 3012 15.40 3091 16.97 3167 18.57 3240 20.19 3310 21.84 3378 23.51
10300 4478 3030 15.21 3066 15.95 3102 16.69 3179 18.30 3253 19.95 3325 21.62 3394 23.32 3461 25.04
10700 4652 3125 16.57 3161 17.33 3195 18.10 3268 19.72 3340 21.41 3411 23.13 3479 24.88 3544 26.65
11100 4826 3221 18.02 3255 18.81 3289 19.60 3357 21.22 3428 22.96 3497 24.73
11500 5000 3317 19.57 3351 20.38 3384 21.19 3449 22.84 3517 24.60

VOLUME O.V. 11" SP 12" SP 13" SP 14" SP 15" SP 16" SP 17" SP


CFM FPM
6000 2608 2842 13.59
6400 2782 2888 14.43 2984 15.79 3075 17.17
6800 2956 2936 15.31 3030 16.71 3122 18.14 3210 19.60 3295 21.08
7200 3130 2983 16.23 3078 17.68 3169 19.16 3256 20.67 3341 22.19 3423 23.74 3503 25.31
7600 3304 3047 17.35 3127 18.72 3216 20.23 3303 21.78 3388 23.35 3470 24.95 3549 26.56
8000 3478 3113 18.55 3193 19.97 3270 21.40 3351 22.94 3435 24.56 3517 26.21
8400 3652 3180 19.82 3259 21.29 3335 22.77 3409 24.27 3483 25.82
8800 3826 3248 21.16 3326 22.68 3401 24.21 3475 25.76 3546 27.33
9200 4000 3316 22.57 3394 24.14 3468 25.73 3541 27.33
9600 4173 3385 24.06 3462 25.68 3536 27.32 NOTE: See pages 25, 28 or 29 for minimum
10000 4347 3464 25.59 3531 27.31 motor frame sizes regardless of BHP.
10400 4521 3546 27.19

Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

15
HDAF-220 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 22.25" Size - 16.88" x 24.88" Size - 24.63" All wheels are HDAF type.
Area - 2.84 Sq. Ft. I.D. Area - 3.24 Sq.Ft. I.D. Class II = light face above Class IIP
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class IIP = bold face below Class II
VOLUME O.V. 0" SP / " SP
1 2 1" SP 11/2" SP 2" SP 21/2" SP 3" SP 31/2" SP
CFM FPM
2500 880 484 .07 670 .27 822 .50
3000 1056 581 .12 743 .37 880 .61 1003 .90
3500 1232 678 .19 821 .49 943 .75 1057 1.06 1160 1.40 1273 1.79
4000 1408 775 .29 904 .62 1015 .94 1118 1.25 1215 1.61 1303 2.00 1404 2.43
4500 1584 871 .41 989 .77 1089 1.18 1185 1.49 1276 1.86 1362 2.27 1441 2.70 1527 3.17
5000 1760 968 .56 1076 .95 1169 1.41 1258 1.80 1340 2.16 1423 2.58 1500 3.04 1573 3.51
5500 1936 1065 .75 1164 1.17 1252 1.66 1332 2.15 1412 2.54 1486 2.93 1561 3.41 1633 3.91
6000 2112 1162 .97 1254 1.43 1336 1.95 1412 2.51 1486 2.98 1557 3.40 1624 3.83 1693 4.35
6500 2288 1259 1.23 1344 1.73 1422 2.27 1494 2.86 1561 3.47 1631 3.92 1696 4.38 1757 4.85
7000 2464 1355 1.54 1436 2.07 1509 2.64 1578 3.27 1642 3.92 1705 4.51 1768 5.00 1828 5.50
7500 2640 1452 1.89 1528 2.46 1597 3.05 1663 3.71 1724 4.41 1782 5.12 1843 5.68 1901 6.21
8000 2816 1549 2.30 1620 2.90 1686 3.52 1749 4.21 1808 4.94 1864 5.69 1918 6.43 1975 6.99
8500 2992 1646 2.76 1713 3.39 1776 4.05 1835 4.76 1893 5.52 1947 6.30 1999 7.11 2050 7.85
9000 3169 1743 3.27 1807 3.95 1866 4.64 1923 5.36 1978 6.16 2031 6.98 2081 7.82 2129 8.67
9500 3345 1839 3.85 1900 4.56 1957 5.29 2012 6.03 2065 6.86 2115 7.71 2164 8.58 2211 9.47
10000 3521 1936 4.49 1994 5.23 2049 6.00 2101 6.78 2152 7.62 2201 8.50 2248 9.41 2294 10.34
10500 3697 2033 5.20 2088 5.98 2141 6.78 2191 7.59 2239 8.44 2287 9.36 2333 10.31 2378 11.27
11000 3873 2130 5.98 2183 6.79 2233 7.63 2282 8.48 2328 9.35 2374 10.29 2419 11.27 2462 12.26
11500 4049 2227 6.83 2277 7.68 2326 8.55 2373 9.44 2418 10.34 2462 11.29 2505 12.30 2547 13.33
12000 4225 2324 7.76 2372 8.65 2419 9.56 2464 10.48 2508 11.41 2550 12.36 2592 13.41 2633 14.48
12500 4401 2420 8.77 2467 9.69 2512 10.64 2556 11.60 2598 12.57 2639 13.55 2679 14.60 2719 15.70
13000 4577 2517 9.86 2562 10.82 2606 11.80 2648 12.80 2689 13.80 2729 14.82 2767 15.87 2806 17.01
13500 4753 2614 11.05 2657 12.04 2699 13.06 2740 14.09 2780 15.13 2819 16.18 2856 17.25 2894 18.39
14000 4929 2711 12.32 2753 13.36 2793 14.41 2833 15.47 2872 16.55 2909 17.64 2946 18.74 2982 19.87

VOLUME O.V. 4" SP 41/2" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP
CFM FPM
4500 1584 1614 3.67
5000 1760 1644 4.00 1726 4.54 1803 5.10
5500 1936 1700 4.42 1764 4.95 1833 5.51 1977 6.73
6000 2112 1760 4.89 1823 5.45 1883 6.02 2006 7.22 2138 8.55
6500 2288 1821 5.41 1883 5.99 1942 6.59 2054 7.81 2168 9.13 2291 10.56
7000 2464 1885 6.00 1944 6.58 2003 7.20 2113 8.49 2216 9.81 2321 11.22 2436 12.75 2546 14.32
7500 2640 1957 6.74 2011 7.28 2065 7.87 2174 9.21 2275 10.60 2371 12.02 2466 13.50 2575 15.13
8000 2816 2030 7.56 2082 8.12 2133 8.69 2235 9.99 2336 11.43 2430 12.91 2520 14.43 2606 15.98
8500 2992 2104 8.45 2155 9.04 2205 9.65 2299 10.86 2397 12.33 2490 13.87 2580 15.44 2664 17.05
9000 3169 2179 9.42 2229 10.05 2278 10.68 2370 11.96 2459 13.29 2552 14.88 2640 16.51 2724 18.18
9500 3345 2257 10.38 2304 11.13 2352 11.80 2443 13.14 2528 14.49 2613 15.96 2701 17.65 2784 19.37
10000 3521 2338 11.28 2381 12.24 2427 13.00 2516 14.40 2600 15.82 2681 17.25 2762 18.85 2845 20.64
10500 3697 2421 12.25 2463 13.24 2503 14.25 2590 15.77 2673 17.25 2752 18.74 2828 20.24 2907 21.97
11000 3873 2504 13.28 2545 14.31 2585 15.35 2665 17.23 2747 18.77 2825 20.32 2900 21.89 2972 23.47
11500 4049 2588 14.38 2628 15.45 2667 16.53 2742 18.73 2821 20.40 2898 22.01 2972 23.64 3043 25.28
12000 4225 2673 15.56 2712 16.66 2750 17.77 2823 20.05 2896 22.13 2972 23.81 3045 25.50 3115 27.20
12500 4401 2758 16.82 2796 17.95 2834 19.10 2905 21.44 2974 23.84 3047 25.72 3119 27.47 3188 29.24
13000 4577 2844 18.16 2882 19.33 2918 20.51 2988 22.92 3056 25.38 3122 27.75 3193 29.57
13500 4753 2931 19.58 2967 20.79 3003 22.00 3072 24.48 3138 27.01
14000 4929 3018 21.09 3054 22.33 3088 23.59 3156 26.13

VOLUME O.V. 11" SP 12" SP 13" SP 14" SP 15" SP


CFM FPM
7500 2640 2679 16.80
8000 2816 2709 17.70 2808 19.47 2904 21.27
8500 2992 2746 18.69 2838 20.46 2933 22.32 3025 24.21 3114 26.14
9000 3169 2805 19.87 2882 21.60 2963 23.41 3054 25.36 3143 27.34
9500 3345 2864 21.12 2941 22.91 3015 24.72 3087 26.57 3173 28.59
10000 3521 2924 22.45 3001 24.29 3074 26.16 3146 28.06
10500 3697 2985 23.84 3061 25.74 3134 27.67
11000 3873 3047 25.31 3122 27.27 3195 29.25
NOTE: See pages 25, 28 or 29 for minimum
11500 4049 3111 26.93 3184 28.87 motor frame sizes regardless of BHP.
12000 4225 3183 28.91
Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

16
HDAF-240 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 24.50" Size - 18.56" x 27.38" Size - 27.00" All wheels are HDAF type.
Area - 3.45 Sq. Ft. I.D. Area - 3.90 Sq.Ft. I.D. Class II = light face above Class IIP
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class IIP = bold face below Class II
VOLUME O.V. 0" SP 1/2" SP 1" SP 11/2" SP 2" SP 21/2" SP 3" SP 31/2" SP
CFM FPM
3000 869 435 .08 605 .32 745 .60
3600 1043 522 .14 671 .44 796 .73 909 1.09
4200 1217 609 .23 740 .58 852 .89 956 1.27 1052 1.69
4800 1391 696 .34 815 .73 916 1.12 1010 1.49 1099 1.93 1181 2.40
5400 1565 783 .48 891 .91 983 1.40 1070 1.78 1153 2.23 1232 2.72 1304 3.24 1384 3.81
6000 1739 870 .66 969 1.13 1054 1.68 1136 2.14 1211 2.57 1286 3.09 1357 3.64 1423 4.21
6600 1913 957 .88 1048 1.38 1129 1.98 1202 2.56 1275 3.02 1342 3.50 1411 4.08 1476 4.68
7200 2086 1044 1.14 1129 1.69 1204 2.31 1273 2.99 1341 3.54 1406 4.05 1467 4.57 1531 5.21
7800 2260 1131 1.45 1210 2.04 1281 2.70 1347 3.41 1409 4.12 1472 4.67 1531 5.22 1587 5.78
8400 2434 1218 1.81 1292 2.44 1359 3.13 1422 3.89 1480 4.68 1539 5.36 1596 5.95 1651 6.55
9000 2608 1305 2.23 1375 2.90 1438 3.62 1498 4.42 1554 5.25 1607 6.11 1663 6.76 1716 7.39
9600 2782 1392 2.70 1458 3.42 1518 4.17 1575 5.00 1629 5.88 1681 6.78 1731 7.65 1783 8.32
10200 2956 1479 3.24 1541 4.00 1598 4.80 1653 5.65 1705 6.56 1755 7.51 1802 8.48 1850 9.33
10800 3130 1566 3.85 1625 4.65 1680 5.49 1732 6.36 1782 7.32 1830 8.30 1876 9.31 1920 10.35
11400 3304 1653 4.53 1709 5.37 1761 6.25 1811 7.15 1860 8.14 1906 9.17 1951 10.22 1994 11.29
12000 3478 1740 5.28 1793 6.17 1844 7.09 1891 8.03 1938 9.04 1983 10.11 2026 11.20 2068 12.31
12600 3652 1827 6.11 1878 7.05 1926 8.01 1972 8.99 2017 10.01 2060 11.12 2102 12.26 2143 13.41
13200 3826 1914 7.02 1963 8.00 2009 9.01 2053 10.03 2096 11.07 2138 12.22 2179 13.39 2219 14.59
13800 4000 2001 8.03 2048 9.05 2092 10.10 2135 11.16 2176 12.25 2217 13.39 2256 14.61 2295 15.85
14400 4173 2088 9.12 2133 10.19 2176 11.28 2217 12.38 2257 13.51 2296 14.66 2334 15.92 2372 17.21
15000 4347 2175 10.31 2218 11.42 2260 12.55 2300 13.70 2338 14.87 2376 16.05 2413 17.32 2450 18.65
15600 4521 2262 11.60 2304 12.75 2344 13.93 2382 15.12 2420 16.33 2456 17.55 2492 18.82 2528 20.19
16200 4695 2349 12.99 2389 14.18 2428 15.40 2465 16.64 2502 17.89 2537 19.15 2572 20.44 2606 21.82
16800 4869 2437 14.48 2475 15.72 2512 16.98 2549 18.26 2584 19.56 2618 20.86 2652 22.19 2685 23.56
17400 5043 2524 16.09 2561 17.37 2597 18.68 2632 20.00 2666 21.34 2700 22.69 2733 24.05 2765 25.43

VOLUME O.V. 4" SP 41/2" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP
CFM FPM
5400 1565 1464 4.41
6000 1739 1490 4.81 1564 5.46 1635 6.14
6600 1913 1538 5.30 1596 5.94 1661 6.63
7200 2086 1591 5.86 1649 6.53 1703 7.21 1818 8.68
7800 2260 1646 6.47 1703 7.17 1757 7.89 1858 9.37 1965 10.97
8400 2434 1703 7.15 1758 7.87 1811 8.62 1911 10.17 2005 11.77 2104 13.48 2209 15.33 2308 17.23
9000 2608 1767 8.03 1816 8.67 1866 9.42 1966 11.03 2058 12.70 2145 14.41 2235 16.23 2335 18.19
9600 2782 1833 8.99 1880 9.67 1926 10.36 2021 11.96 2112 13.69 2198 15.47 2280 17.30 2361 19.20
10200 2956 1899 10.05 1946 10.76 1991 11.49 2077 12.95 2167 14.75 2252 16.61 2333 18.50 2410 20.44
10800 3130 1966 11.19 2012 11.95 2056 12.71 2140 14.25 2222 15.89 2307 17.81 2387 19.77 2464 21.78
11400 3304 2035 12.39 2079 13.23 2123 14.03 2205 15.64 2284 17.27 2362 19.09 2442 21.12 2518 23.20
12000 3478 2108 13.45 2147 14.61 2190 15.46 2271 17.14 2348 18.84 2421 20.56 2497 22.55 2572 24.70
12600 3652 2182 14.59 2220 15.79 2258 16.99 2338 18.75 2413 20.53 2486 22.32 2555 24.13 2628 26.28
13200 3826 2257 15.81 2294 17.05 2331 18.31 2405 20.48 2479 22.33 2550 24.20 2619 26.08 2684 27.98
13800 4000 2332 17.11 2369 18.40 2404 19.69 2473 22.33 2546 24.26 2616 26.20 2683 28.15 2748 30.12
14400 4173 2408 18.51 2444 19.83 2479 21.17 2546 23.90 2614 26.31 2683 28.32 2749 30.35 2813 32.39
15000 4347 2485 19.99 2520 21.36 2554 22.74 2619 25.56 2682 28.44 2750 30.58 2815 32.69 2878 34.80
15600 4521 2562 21.57 2596 22.98 2629 24.40 2694 27.30 2755 30.27 2817 32.98 2882 35.16
16200 4695 2640 23.25 2673 24.70 2706 26.17 2768 29.15 2829 32.20 2887 35.31
16800 4869 2718 25.04 2751 26.53 2782 28.04 2844 31.10
17400 5043 2797 26.93 2828 28.46 2859 30.01

VOLUME O.V. 11" SP 12" SP 13" SP 14" SP 15" SP


CFM FPM
9000 2608 2429 20.21
9600 2782 2456 21.28 2546 23.41
10200 2956 2484 22.41 2572 24.59 2659 26.84 2743 29.12 2823 31.44
10800 3130 2537 23.82 2608 25.90 2686 28.13 2769 30.49 2849 32.88
11400 3304 2590 25.31 2660 27.46 2728 29.65 2796 31.90 2876 34.36
12000 3478 2644 26.88 2714 29.10 2781 31.35 2846 33.64
12600 3652 2699 28.53 2768 30.82 2835 33.15 2899 35.50
13200 3826 2755 30.28 2823 32.63 2889 35.03 NOTE: See pages 25, 28 or 29 for minimum
13800 4000 2810 32.11 2878 34.54 motor frame sizes regardless of BHP.
14400 4173 2874 34.45

Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

17
HDAF-270 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 27.00" Size - 20.44" x 30.13" Size - 30.00" All wheels are HDAF type.
Area - 4.19 Sq. Ft. I.D. Area - 4.83 Sq.Ft. I.D. Class II = light face above Class III
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class III = italic face below Class II
3
VOLUME O.V. 0" SP / " SP
1 4 / " SP
1 2 /4" SP 1" SP 11/2" SP 2" SP 21/2" SP
CFM FPM
2500 596 245 .04 343 .13
3250 775 318 .08 397 .20 470 .33
4000 954 392 .15 457 .30 518 .45 576 .61 646 .83
4750 1133 465 .26 520 .42 573 .61 623 .79 672 .98

5500 1312 539 .40 587 .59 633 .80 677 1.02 721 1.22 809 1.68
6250 1491 612 .58 655 .80 696 1.03 736 1.27 775 1.52 849 2.00 931 2.55 1019 3.23
7000 1670 685 .82 724 1.06 760 1.31 797 1.58 833 1.86 901 2.40 965 2.93 1041 3.57
7750 1849 759 1.11 794 1.37 827 1.65 860 1.93 893 2.24 956 2.86 1017 3.44 1074 4.04
8500 2028 832 1.46 865 1.75 895 2.05 924 2.35 955 2.68 1014 3.36 1071 4.02 1126 4.66
9250 2207 906 1.88 936 2.20 964 2.52 991 2.85 1018 3.19 1074 3.92 1126 4.67 1179 5.36
10000 2386 979 2.38 1007 2.72 1034 3.07 1059 3.42 1083 3.78 1136 4.55 1186 5.35 1233 6.15
10750 2565 1053 2.96 1079 3.32 1104 3.69 1128 4.07 1150 4.45 1198 5.26 1246 6.10 1291 6.97
11500 2744 1126 3.62 1151 4.01 1174 4.40 1197 4.81 1218 5.21 1262 6.05 1308 6.95 1351 7.86
12250 2923 1199 4.38 1223 4.79 1245 5.21 1266 5.64 1287 6.07 1327 6.94 1370 7.88 1412 8.84
13000 3102 1273 5.23 1295 5.67 1316 6.11 1336 6.56 1356 7.02 1394 7.94 1433 8.91 1474 9.92
13750 3281 1346 6.19 1367 6.65 1387 7.12 1406 7.60 1425 8.07 1462 9.05 1497 10.04 1536 11.10
14500 3460 1420 7.26 1439 7.74 1458 8.24 1477 8.74 1495 9.24 1530 10.26 1564 11.30 1599 12.39
15250 3639 1493 8.44 1512 8.95 1530 9.48 1548 10.00 1565 10.53 1599 11.60 1631 12.68 1663 13.79
16000 3818 1567 9.75 1584 10.29 1602 10.83 1619 11.38 1636 11.93 1668 13.05 1699 14.18 1729 15.34
16750 3997 1640 11.19 1657 11.75 1674 12.32 1690 12.89 1706 13.47 1737 14.63 1768 15.82 1797 17.01
17500 4176 1714 12.76 1730 13.35 1746 13.94 1762 14.54 1777 15.14 1807 16.35 1836 17.58 1865 18.83
18250 4355 1787 14.47 1803 15.08 1818 15.70 1833 16.32 1848 16.95 1877 18.21 1905 19.49 1933 20.78
19000 4534 1860 16.33 1875 16.97 1890 17.61 1905 18.26 1919 18.91 1947 20.22 1974 21.55 2001 22.89
19750 4713 1934 18.34 1948 19.00 1963 19.67 1977 20.35 1990 21.02 2018 22.38 2044 23.75 2070 25.14
20500 4892 2007 20.51 2021 21.20 2035 21.89 2049 22.59 2062 23.29 2088 24.70 2114 26.12 2139 27.56
21250 5071 2081 22.85 2094 23.54 2107 24.27 2121 25.00 2134 25.73 2159 27.18 2184 28.65 2208 30.14

VOLUME O.V. 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP 9" SP 10" SP
CFM FPM
8500 2028 1177 5.32 1306 6.97
9250 2207 1229 6.06 1332 7.58 1453 9.50
10000 2386 1282 6.90 1372 8.42 1475 10.20 1588 12.35
10750 2565 1336 7.82 1424 9.43 1509 11.14 1610 13.18 1714 15.49
11500 2744 1393 8.80 1477 10.54 1556 12.29 1639 14.20 1736 16.46 1832 18.94 1945 22.69
12250 2923 1452 9.83 1531 11.76 1608 13.60 1680 15.48 1763 17.58 1854 20.04 1967 23.93 2053 26.73
13000 3102 1513 10.95 1586 13.07 1662 15.01 1732 16.98 1799 18.99 1880 21.28 1992 25.30 2075 28.11
13750 3281 1574 12.18 1646 14.39 1716 16.55 1785 18.61 1851 20.70 1915 22.87 2028 27.08 2100 29.65
14500 3460 1636 13.51 1706 15.82 1771 18.19 1839 20.35 1903 22.54 1965 24.76 2075 29.16 2136 31.63
15250 3639 1699 14.96 1766 17.37 1830 19.83 1893 22.23 1957 24.51 2017 26.82 2127 31.44 2182 33.90
16000 3818 1762 16.54 1828 19.03 1890 21.59 1949 24.21 2010 26.62 2070 29.02 2180 33.88 2234 36.43
16750 3997 1826 18.23 1890 20.82 1951 23.48 2008 26.19 2065 28.87 2124 31.36 2233 36.46 2287 39.10
17500 4176 1892 20.09 1952 22.75 2012 25.50 2068 28.30 2122 31.16 2178 33.85 2287 39.21 2340 41.94
18250 4355 1959 22.09 2015 24.81 2073 27.66 2129 30.55 2182 33.51 2233 36.50 2342 42.11 2394 44.94
19000 4534 2027 24.24 2079 27.02 2136 29.96 2190 32.95 2242 36.00 2292 39.09 2399 45.07 2448 48.10
19750 4713 2095 26.55 2144 29.39 2198 32.41 2251 35.50 2302 38.64 2351 41.83 2458 48.05
20500 4892 2163 29.01 2211 31.95 2261 35.02 2313 38.20 2363 41.44 2412 44.72
21250 5071 2232 31.63 2278 34.67 2325 37.78 2376 41.07 2425 44.40 2472 47.78

VOLUME O.V. 11" SP 12" SP 13" SP 14" SP


CFM FPM
13000 3102 2134 29.59
13750 3281 2156 31.07 2234 34.08
14500 3460 2178 32.59 2256 35.70 2331 38.86
15250 3639 2205 34.33 2278 37.37 2353 40.63 2425 43.94
16000 3818 2240 36.50 2306 39.34 2375 42.46 2447 45.86
16750 3997 2286 39.00 2342 41.72 2405 44.68 2469 47.84
17500 4176 2338 41.77 2388 44.46 2440 47.27 NOTE: See pages 25, 28 or 29 for minimum
motor frame sizes regardless of BHP.
18250 4355 2391 44.69 2440 47.47
19000 4534 2444 47.78

Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

18
HDAF-300 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 30.00" Size - 22.75" x 33.56" Size - 33.50" All wheels are HDAF type.
Area - 5.20 Sq. Ft. I.D. Area - 6.12 Sq.Ft. I.D. Class II = light face above Class III
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class III = italic face below Class II
3
VOLUME O.V. 0" SP / " SP
1 4 / " SP
1 2 /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
4600 884 328 .15 391 .32 448 .50 510 .71
5400 1038 385 .25 439 .44 490 .65 537 .86 591 1.10
6200 1192 443 .37 489 .59 535 .83 578 1.07 619 1.31 715 1.91
7000 1346 500 .54 542 .78 583 1.04 621 1.33 660 1.59 734 2.15 822 2.89
7800 1500 557 .74 595 1.01 631 1.30 668 1.60 702 1.92 768 2.51 839 3.18
8600 1653 614 .99 649 1.29 681 1.59 715 1.93 747 2.27 809 2.94 866 3.59
9400 1807 671 1.30 703 1.62 733 1.95 764 2.30 794 2.67 851 3.42 907 4.13
10200 1961 728 1.66 758 2.00 786 2.36 813 2.73 842 3.13 896 3.95 948 4.73
11000 2115 785 2.08 813 2.45 840 2.84 864 3.23 891 3.64 942 4.51 991 5.40
11800 2269 842 2.57 869 2.97 893 3.38 917 3.79 940 4.22 990 5.14 1035 6.10
12600 2423 899 3.13 924 3.55 948 3.99 970 4.43 991 4.88 1038 5.85 1082 6.85
13400 2576 957 3.76 980 4.21 1002 4.67 1023 5.14 1044 5.62 1086 6.62 1129 7.67
14200 2730 1014 4.47 1036 4.95 1057 5.44 1077 5.94 1097 6.44 1136 7.47 1177 8.58
15000 2884 1071 5.27 1092 5.78 1112 6.29 1131 6.81 1150 7.34 1186 8.42 1226 9.57
15800 3038 1128 6.16 1148 6.69 1167 7.23 1186 7.78 1204 8.33 1238 9.46 1274 10.64
16600 3192 1185 7.15 1204 7.70 1222 8.27 1240 8.84 1257 9.42 1291 10.60 1324 11.81
17400 3346 1242 8.23 1260 8.81 1278 9.41 1295 10.01 1312 10.61 1344 11.84 1375 13.09
18200 3500 1299 9.42 1316 10.03 1333 10.65 1350 11.27 1366 11.90 1397 13.18 1427 14.49
19000 3653 1356 10.72 1373 11.35 1389 12.00 1405 12.65 1420 13.31 1451 14.64 1480 15.99
19800 3807 1413 12.13 1429 12.78 1445 13.46 1460 14.14 1475 14.82 1504 16.21 1532 17.61
20600 3961 1470 13.66 1486 14.35 1501 15.05 1516 15.75 1530 16.46 1558 17.89 1586 19.35
21400 4115 1528 15.31 1542 16.03 1557 16.75 1571 17.48 1585 18.22 1612 19.71 1639 21.21
22200 4269 1585 17.09 1599 17.82 1613 18.58 1627 19.35 1640 20.10 1667 21.64 1692 23.20
23000 4423 1642 19.01 1656 19.77 1669 20.56 1682 21.34 1696 22.12 1721 23.72 1746 25.32
23800 4576 1699 21.06 1712 21.85 1725 22.66 1738 23.47 1751 24.29 1776 25.93 1800 27.59
24600 4730 1756 23.26 1769 24.06 1782 24.91 1794 25.74 1806 26.59 1831 28.28 1854 29.99
25400 4884 1813 25.60 1826 26.45 1838 27.31 1850 28.17 1862 29.03 1886 30.78 1909 32.55
26200 5038 1870 28.10 1882 28.95 1894 29.84 1906 30.74 1918 31.64 1941 33.44 1963 35.25

VOLUME O.V. 21/2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP


CFM FPM
7800 1500 919 4.02
8600 1653 936 4.39 1008 5.32
9400 1807 960 4.87 1025 5.75
10200 1961 998 5.50 1049 6.32 1169 8.38
11000 2115 1039 6.22 1085 7.06 1186 8.97 1299 11.35
11800 2269 1081 7.01 1126 7.90 1212 9.76 1316 12.07 1417 14.66
12600 2423 1124 7.88 1167 8.81 1247 10.73 1334 12.85 1434 15.51
13400 2576 1170 8.75 1209 9.82 1288 11.83 1362 13.92 1451 16.39 1545 19.28
14200 2730 1216 9.71 1254 10.87 1329 13.02 1400 15.18 1475 17.52 1562 20.30 1649 23.38
15000 2884 1264 10.75 1300 11.96 1371 14.31 1441 16.57 1506 18.87 1582 21.46 1666 24.54
15800 3038 1312 11.88 1347 13.13 1414 15.69 1482 18.05 1546 20.45 1610 22.95 1683 25.74
16600 3192 1360 13.10 1394 14.41 1459 17.09 1524 19.64 1587 22.14 1647 24.68 1711 27.41
17400 3346 1409 14.42 1442 15.77 1506 18.56 1567 21.34 1629 23.94 1687 26.58 1743 29.26
18200 3500 1458 15.84 1491 17.25 1553 20.13 1611 23.10 1671 25.86 1728 28.59 1783 31.37
19000 3653 1507 17.36 1539 18.83 1600 21.81 1657 24.88 1713 27.90 1770 30.73 1824 33.60
19800 3807 1560 19.03 1589 20.52 1648 23.60 1704 26.77 1757 30.01 1812 33.00 1865 35.96
20600 3961 1612 20.82 1638 22.32 1696 25.51 1751 28.78 1803 32.12 1854 35.39 1907 38.46
21400 4115 1665 22.73 1690 24.28 1745 27.54 1798 30.91 1849 34.35 1898 37.85 1949 41.09
22200 4269 1717 24.77 1742 26.37 1794 29.70 1846 33.17 1896 36.71 1944 40.31 1992 43.87
23000 4423 1771 26.95 1794 28.59 1843 31.99 1894 35.56 1944 39.20 1991 42.90 2036 46.67
23800 4576 1824 29.26 1847 30.96 1892 34.41 1943 38.08 1991 41.83 2038 45.63
24600 4730 1877 31.72 1900 33.47 1944 37.00 1992 40.75 2039 44.59
25400 4884 1931 34.32 1953 36.12 1996 39.76 2041 43.56
26200 5038 1985 37.08 2007 38.93 2048 42.67
VOLUME O.V. 9" SP 10" SP 11" SP 12" SP
CFM FPM
14800 2846 1743 27.48
15600 3000 1760 28.77 1838 32.18 NOTE: See pages 25, 28 or 29 for minimum
16400 3153 1777 30.10 1854 33.61 1928 37.20 motor frame sizes regardless of BHP.
17200 3307 1800 31.73 1871 35.09 1945 38.78 2015 42.54
18000 3461 1828 33.67 1893 36.82 1962 40.40 2032 44.26
18800 3615 1866 35.91 1921 38.96 1982 42.26 2049 46.03
19600 3769 1907 38.34 1956 41.36 2011 44.60 2069 48.04
20400 3923 1948 40.90 1996 44.01 2044 47.16
21200 4076 1989 43.60 2037 46.81
22000 4230 2031 46.44
22800 4384 2073 49.42
Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.
19
HDAF-330 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 33.00" Size - 24.88" x 36.88" Size - 36.75" All wheels are HDAF type.
Area - 6.2 Sq. Ft. I.D. Area - 7.20 Sq.Ft. I.D. Class II = light face above Class III
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class III = italic face below Class II
3
VOLUME O.V. 0" SP / " SP
1 4 / " SP
1 2 /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
5000 806 268 .13 331 .32 388 .52
6200 1000 333 .25 384 .48 432 .72 478 .96 532 1.27
7400 1193 397 .43 440 .69 482 .98 522 1.27 559 1.55 648 2.29
8600 1387 461 .68 499 .98 535 1.30 570 1.65 605 1.97 671 2.66 750 3.54
9800 1580 526 1.00 559 1.34 590 1.70 623 2.08 653 2.48 712 3.22 771 4.02
11000 1774 590 1.42 620 1.80 648 2.19 677 2.60 705 3.04 759 3.90 810 4.74
12200 1967 654 1.94 682 2.35 708 2.78 732 3.23 759 3.70 808 4.68 857 5.61
13400 2161 719 2.57 744 3.02 768 3.49 790 3.97 814 4.47 861 5.53 904 6.61
14600 2354 783 3.32 806 3.81 828 4.32 850 4.84 870 5.36 914 6.50 955 7.67
15800 2548 847 4.21 869 4.74 890 5.29 910 5.84 929 6.41 969 7.60 1008 8.85
17000 2741 912 5.24 932 5.82 951 6.40 970 6.99 988 7.60 1024 8.84 1062 10.17
18200 2935 976 6.43 995 7.04 1013 7.67 1031 8.30 1048 8.94 1081 10.25 1116 11.64
19400 3129 1040 7.79 1058 8.44 1075 9.11 1092 9.78 1108 10.46 1140 11.84 1172 13.28
20600 3322 1105 9.33 1122 10.02 1138 10.72 1154 11.43 1169 12.15 1199 13.61 1228 15.09
21800 3516 1169 11.06 1185 11.79 1201 12.53 1216 13.28 1230 14.04 1259 15.57 1286 17.13
23000 3709 1233 12.98 1249 13.76 1263 14.54 1278 15.33 1292 16.12 1319 17.73 1346 19.37
24200 3903 1298 15.12 1312 15.93 1326 16.75 1340 17.58 1354 18.42 1380 20.11 1405 21.82
25400 4096 1362 17.49 1376 18.34 1389 19.20 1403 20.06 1415 20.94 1441 22.70 1465 24.50
26600 4290 1427 20.08 1440 20.97 1453 21.87 1465 22.78 1478 23.70 1502 25.54 1525 27.40
27800 4483 1491 22.93 1503 23.85 1516 24.80 1528 25.74 1540 26.70 1563 28.62 1586 30.56
29000 4677 1555 26.02 1567 27.00 1579 27.97 1591 28.96 1602 29.95 1625 31.95 1647 33.97
30200 4870 1620 29.39 1631 30.39 1643 31.42 1654 32.45 1665 33.48 1687 35.56 1708 37.65
31400 5064 1684 33.04 1695 34.09 1706 35.14 1717 36.21 1728 37.28 1749 39.44 1769 41.62
32600 5258 1748 36.97 1759 38.06 1770 39.15 1780 40.26 1790 41.37 1811 43.61 1831 45.87

VOLUME O.V. 21/2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP


CFM FPM
9800 1500 841 5.03
11000 1774 863 5.65 926 6.76 NOTE: See pages 26 or 30 for minimum
12200 1967 902 6.54 950 7.54 1061 10.04 motor frame sizes regardless of BHP.
13400 2161 948 7.61 989 8.63 1080 10.93 1182 13.82
14600 2354 996 8.82 1036 9.91 1110 12.16 1202 14.92 1294 18.08
15800 2548 1045 10.13 1083 11.35 1155 13.73 1227 16.29 1313 19.39 1398 22.82
17000 2741 1098 11.52 1132 12.91 1201 15.48 1266 18.07 1337 20.93 1417 24.35 1496 28.04
18200 2935 1151 13.07 1184 14.54 1249 17.40 1312 20.13 1371 22.93 1440 26.08 1515 29.79
19400 3129 1205 14.79 1237 16.33 1297 19.49 1359 22.39 1417 25.33 1471 28.32 1537 31.75
20600 3322 1260 16.68 1291 18.30 1349 21.61 1406 24.84 1463 27.93 1516 31.07 1569 34.29
21800 3516 1315 18.76 1345 20.45 1402 23.91 1455 27.47 1510 30.74 1563 34.03 1613 37.36
23000 3709 1371 21.03 1400 22.80 1455 26.41 1507 30.12 1558 33.78 1609 37.21 1659 40.69
24200 3903 1430 23.56 1455 25.36 1509 29.13 1559 32.99 1607 36.93 1657 40.64 1705 44.26
25400 4096 1489 26.31 1512 28.14 1563 32.06 1613 36.07 1660 40.17 1705 44.31 1752 48.08
26600 4290 1548 29.29 1571 31.20 1618 35.22 1667 39.38 1712 43.63 1756 47.96 1800 52.16
27800 4483 1608 32.52 1630 34.51 1674 38.62 1721 42.93 1766 47.33 1809 51.81 1850 56.37
29000 4677 1668 36.02 1689 38.08 1730 42.27 1776 46.74 1819 51.29 1861 55.92 1902 60.62
30200 4870 1729 39.77 1749 41.91 1788 46.25 1831 50.81 1874 55.51 1915 60.30 1955 65.15
31400 5064 1789 43.81 1809 46.03 1847 50.51 1886 55.15 1928 60.01 1969 64.94 2008 69.94
32600 5258 1850 48.14 1869 50.43 1906 55.07 1942 59.78 1983 64.78

VOLUME O.V. 9" SP 10" SP 11" SP 12" SP 13" SP 14" SP


CFM FPM
17800 2870 1583 33.08
19000 3064 1602 35.04 1673 39.17
20200 3258 1622 37.07 1692 41.36 1759 45.73 1823 50.18
21400 3451 1652 39.83 1711 43.63 1778 48.15 1842 52.76 1903 57.45
22600 3645 1691 43.02 1743 46.76 1799 50.77 1861 55.42 1922 60.26 1981 65.18
23800 3838 1736 46.66 1781 50.31 1830 54.23 1884 58.45 1942 63.17 2000 68.24
25000 4032 1783 50.54 1827 54.34 1870 58.18 1915 62.25 1967 66.67
26200 4225 1830 54.68 1873 58.63 1915 62.62 1956 66.64 1998 70.82
27400 4419 1877 59.09 1920 63.19 1962 67.32 2002 71.49
28600 4612 1925 63.78 1967 68.03
29800 4806 1976 68.48
Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

Note: HDAF-330 has a fixed housing and is therefore not rotatable in the field.

20
HDAF-360 BELT DRIVE RATING TABLES
Ratings at 70˚F., .075 Density, Sea Level
WHEEL OUTLET O.D. INLET O.D.
Dia. - 36.00" Size - 27.25" x 40.25" Size - 40" All wheels are HDAF type.
Area - 7.50 Sq. Ft. I.D. Area - 8.10 Sq.Ft. I.D. Class II = light face above Class III
SEE PAGE 22 FOR MAX. WHEEL RPM & WR2. Class III = italic face below Class II
3
VOLUME O.V. 0" SP / " SP
1 4 / " SP
1 2 /4" SP 1" SP 11/2" SP 2" SP
CFM FPM
6000 800 248 .16 305 .39 357 .62
7500 1000 310 .32 356 .59 400 .88 440 1.17 489 1.54
9000 1200 372 .55 410 .86 448 1.22 484 1.57 518 1.91 597 2.77
10500 1400 434 .87 468 1.23 500 1.63 532 2.05 562 2.45 620 3.27 691 4.31
12000 1600 496 1.30 526 1.71 553 2.14 583 2.61 610 3.10 663 4.01 714 4.96
13500 1800 558 1.85 585 2.31 610 2.79 635 3.30 661 3.83 708 4.90 755 5.92
15000 2000 620 2.54 644 3.05 667 3.58 689 4.12 713 4.70 757 5.90 800 7.06
16500 2200 682 3.38 704 3.94 725 4.52 745 5.10 766 5.71 808 7.01 846 8.35
18000 2400 744 4.39 764 5.00 784 5.63 803 6.26 821 6.91 860 8.29 897 9.72
19500 2600 806 5.59 825 6.25 843 6.92 861 7.60 878 8.29 913 9.74 948 11.27
21000 2800 867 6.98 885 7.69 903 8.41 919 9.14 935 9.88 966 11.39 1000 13.02
22500 3000 929 8.58 946 9.34 962 10.11 978 10.89 993 11.68 1022 13.28 1053 14.98
24000 3200 991 10.42 1007 11.22 1022 12.04 1037 12.87 1052 13.71 1079 15.41 1107 17.16
25500 3400 1053 12.49 1068 13.35 1083 14.22 1097 15.09 1110 15.98 1137 17.78 1162 19.61
27000 3600 1115 14.83 1129 15.74 1143 16.65 1156 17.58 1170 18.52 1195 20.41 1219 22.33
28500 3800 1177 17.44 1191 18.39 1204 19.36 1216 20.34 1229 21.32 1253 23.31 1277 25.33
30000 4000 1239 20.34 1252 21.35 1264 22.36 1276 23.39 1288 24.42 1312 26.51 1334 28.62
31500 4200 1301 23.55 1313 24.60 1325 25.67 1337 26.75 1348 27.83 1371 30.01 1392 32.22
33000 4400 1363 27.08 1375 28.17 1386 29.29 1397 30.42 1408 31.55 1430 33.83 1451 36.14
34500 4600 1425 30.94 1436 32.09 1447 33.26 1458 34.43 1468 35.61 1489 37.99 1509 40.40
36000 4800 1487 35.15 1498 36.35 1508 37.56 1518 38.80 1529 40.02 1548 42.50 1568 45.00
37500 5000 1549 39.73 1559 40.97 1569 42.24 1579 43.51 1589 44.80 1608 47.37 1627 49.98
39000 5200 1611 44.69 1621 45.97 1630 47.32 1640 48.62 1649 49.96 1668 52.64 1686 55.33

VOLUME O.V. 21/2" SP 3" SP 4" SP 5" SP 6" SP 7" SP 8" SP


CFM FPM
12000 1600 775 6.14
13500 1800 800 6.99 854 8.27 NOTE: See pages 26 or 30 for minimum
15000 2000 841 8.19 880 9.36 978 12.30
16500 2200 886 9.59 923 10.84 1000 13.54 1091 16.94 motor frame sizes regardless of BHP.

18000 2400 932 11.18 968 12.52 1035 15.26 1109 18.35 1194 22.19
19500 2600 982 12.84 1014 14.41 1079 17.33 1139 20.33 1212 23.87 1290 28.04
21000 2800 1033 14.68 1063 16.38 1125 19.62 1183 22.80 1241 26.13 1309 29.99 1381 34.48
22500 3000 1084 16.74 1114 18.53 1170 22.15 1228 25.51 1281 28.94 1336 32.58 1400 36.72
24000 3200 1137 19.01 1165 20.90 1219 24.78 1273 28.48 1326 32.09 1375 35.76 1428 39.70
25500 3400 1190 21.53 1217 23.52 1270 27.58 1319 31.72 1371 35.52 1419 39.37 1465 43.28
27000 3600 1243 24.30 1270 26.38 1321 30.64 1369 35.00 1416 39.24 1464 43.27 1509 47.36
28500 3800 1299 27.38 1323 29.52 1373 33.96 1419 38.52 1463 43.18 1510 47.48 1554 51.75
30000 4000 1356 30.77 1377 32.94 1425 37.58 1471 42.32 1514 47.17 1556 52.01 1600 56.47
31500 4200 1413 34.46 1434 36.72 1478 41.49 1522 46.42 1564 51.46 1605 56.59 1645 61.53
33000 4400 1471 38.47 1491 40.83 1531 45.71 1574 50.84 1616 56.07 1655 61.38 1693 66.79
34500 4600 1529 42.83 1548 45.28 1585 50.26 1627 55.59 1667 61.00 1706 66.51 1743 72.10
36000 4800 1587 47.53 1605 50.07 1641 55.25 1680 60.68 1719 66.28 1757 71.98 1794 77.76
37500 5000 1645 52.60 1663 55.24 1698 60.60 1734 66.12 1772 71.93 1809 77.81 1845 83.78
39000 5200 1704 58.05 1721 60.79 1755 66.34 1788 71.97 1825 77.94 1861 84.02

VOLUME O.V. 9" SP 10" SP 11" SP 12" SP 13" SP 14" SP


CFM FPM
21500 2866 1455 39.88
23000 3066 1474 42.35 1538 47.32 1599 52.39
24500 3266 1495 45.11 1557 50.08 1618 55.34 1676 60.70
26000 3466 1525 48.69 1579 53.29 1636 58.41 1695 63.96 1751 69.61 1805 75.35
27500 3666 1567 52.99 1610 57.28 1661 62.14 1714 67.33 1770 73.17 1823 79.10
29000 3866 1612 57.67 1653 62.11 1692 66.60 1741 71.67 1788 76.86 1842 82.98
30500 4066 1657 62.69 1697 67.30 1736 71.97 1773 76.68 1818 81.90 1864 87.32
32000 4266 1702 68.05 1742 72.85 1780 77.69 1817 82.58 1853 87.52
33500 4466 1748 73.77 1787 78.75 1825 83.78 1862 88.86
35000 4666 1796 79.69 1833 85.04
36500 4866 1846 85.66
Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free
inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

Note: HDAF-360 has a fixed housing and is therefore not rotatable in the field.

21
DESIGN SPECIFICATIONS

DIMENSIONS and SPECIFICATIONS


NOTE: The table below contains blower housing dimensions common to all arrangements on pages 23 and 25 through 28.
MODEL C➀ D➁➂
HDAF-120 4 1/16 9 3/8 15 3/4 16 3/16 19 15/16 12 3/8 13 10 3/8 13 1/4 13 3/4
HDAF-130 4 1/16 10 3/8 16 1/4 16 13/16 10 13/16 13 3/4 14 7/16 11 9/16 14 5/8 15 1/4
HDAF-150 4 1/16 11 3/8 16 3/4 17 9/16 11 3/4 15 3/16 15 15/16 12 3/4 16 1/8 16 13/16
HDAF-160 4 1/16 12 1/2 17 5/16 18 5/16 12 11/16 16 11/16 17 1/2 14 18 18 7/16
HDAF-180 4 1/16 13 7/8 18 19 1/4 13 13/16 18 7/16 19 7/16 15 1/2 20 20 3/8
HDAF-200 4 1/16 15 1/4 18 11/16 10 1/16 14 15/16 20 1/4 21 1/4 17 22 22 3/8
HDAF-220 4 1/16 16 7/8 19 1/2 11 3/16 16 3/8 22 1/2 23 5/8 18 7/8 24 5/8 24 7/8
HDAF-240 6 1/16 18 9/16 10 3/8 12 5/16 18 13/16 24 3/4 26 20 3/4 27 27 3/8
HDAF-270 6 1/16 20 7/16 11 5/16 13 9/16 20 5/8 27 1/4 28 5/8 22 7/8 30 30 1/16
HDAF-300 6 1/16 22 3/4 12 7/16 15 1/8 22 5/8 30 3/8 31 7/8 25 1/2 33 1/2 33 9/16
HDAF-330 3 1/4 24 7/8 14 1/2 16 9/16 24 11/16 33 3/8 35 28 36 3/4 36 7/8
HDAF-360 3 1/4 27 1/4 15 11/16 18 1/8 27 3/16 36 1/2 38 1/4 30 1/2 40 40 1/4
Down Blast

22
DIMENSIONS and SPECIFICATIONS
Arrangement #4, Direct Drive
BOTH SIDES: SIZE, QUANTITY AND LOCATION OF
➁ SUPPORT ANGLES VARY WITH FAN ORIENTATION,
BB HDAF-330 & 360 ONLY.
➀ D
C O P

S
For horizontal mount
(Arrangement 4HM),
O.D.

see Page 24.


AA

M

DD

R
FF
GG H V
HH K Dia. JJ
➀ ➀G (6) Holes
KK
➅ CW-BH
J (Clockwise-Bottom Horizontal)
CC

À Add 1/8" for AMCA “C” Construction fans and/or


HDAF-330 & 360 ONLY

Á Add 1/4" for AMCA “C” Construction fans and/or


Down Blast discharge position.
INLET SIDE PLATE

 Discharge flange (not shown above) is standard on Models


Down Blast discharge position.
DISCHARGE

SHAFT & INLET


JJ
V

Å Inlet side plate width for HDAF-330 & 360. Inlet side plate for
HDAF-270 through HDAF-360. See page 31 for dimensions.
JJ
➅KK

HDAF-120 to HDAF-300 is same width as “JJ” dimension.

H NOTE: HDAF-120 to 300 are reversible and rotatable in 45° increments


J➀ G➀
but wheels are not reversible. HDAF-330 AND 360 ARE NOT
FOUNDATION PLAN ROTATABLE OR REVERSIBLE.

NOTE: For common boxed blower housing dimensions, see Page 22.
MODEL MOTOR ➀ ➁ ➁ ➅
NO. FRAME G H V K BB CC FF GG HH JJ KK
HDAF-120 143T-184T 7.11/16 5.1/2 41 9/16 24 15/16 22 15/16 15 1/2 3 11 1/2 16 —
HDAF-130 143T-215T 8.3/16 7.5/8 51 3/4 9/16 28 1/16 26 1/16 16 5/8 3 13 5/8 17 3/4 —
HDAF-150 143T-215T 8.11/16 7.5/8 71 1/4 9/16 29 1/16 27 1/16 18 1/8 3 13 5/8 19 1/4 —
HDAF-160 143T-184T 7.5/8 30 3/16 28 3/16 13 5/8
9.1/4 91 1/8 9/16 19 3/4 3 21 1/8 —
213T-256T 17 39 9/16 37 9/16 23
HDAF-180 143T-215T 8.3/8 32 5/16 30 5/16 14 3/8
254T-286T 9.15/16 18.1/2 12 1/2 9/16 42 7/16 40 7/16 22 3/4 3 24 1/2 23 1/2 —
324T-326T 21 44 15/16 42 15/16 27
HDAF-200 182T-256T 11.1/2 36 13/16 34 13/16 17 1/2
284T-286T 10.5/8 18.1/2 32 1/2 9/16 43 13/16 41 13/16 23 1/2 3 24 1/2 25 1/2 —
324T-326T 21 46 5/16 44 5/16 27
HDAF-220 182T-256T 11.1/2 38 7/16 36 7/16 17 1/2
11.7/16 62 1/8 9/16 26 1/4 3 28 1/8 —
284T-326T 21 47 15/16 45 15/16 27
HDAF-240 213T-256T 11.1/2 42 1/8 38 1/8 17 1/2
12.5/16 82 1/4 9/16 28 1/2 3 30 3/4 —
284T-326T 21 51 5/8 47 5/8 27
HDAF-270 213T-256T 11.1/2 44 40 17 1/2
13.1/4 13 9/16 31 1/4 3 33 3/4 —
284T-326T 21 53 1/2 49 1/2 27
HDAF-300 213T-256T 11.1/2 46 5/16 42 5/16 17 1/2
14.3/8 43 1/4 9/16 34 1/2 3 37 1/4 —
284T-326T 21 55 13/16 51 13/16 27
HDAF-330 284T-326T 20 55 1/8 54 15/16 27
364T-405T 15.15/16 25 82 3/ 4 60 1/8 59 15/16 38 3/4 31/2 32 30 14 3/4
444T 29 64 1/8 6351 /16 36
HDAF-360 284T-326T 20 57 1/2 57 5/16 27
17.1/8 13 3/4 42 31/2 33 54
364T-405T 25 62 1/2 62 5/16 32
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
23
DIMENSIONS and SPECIFICATIONS
Arrangement #4HM, Direct Drive

NOTE:
Dimensions
shown below are
for 100% width
housings. For
partial width
housings, contact
your local


Cincinnati Fan
sales
representative.

Á and Â
See Notes

À Add 1/8" for AMCA “C” Construction.


Á Optional inlet flange may be added to assist in fan installation. See page 31 for flange dimensions.
 Discharge flange (not shown above) is standard on Models HDAF-270 and HDAF-300. See page 31 for flange dimensions.

MODEL MOTOR ➀* ➂
NO. FRAME C D M 0 P R S DD
HDAF-120 143T-184T 4 1/4 19 3/8 16 3/16 19 15/16 12 3/8 13 10 3/8 13 3/4
HDAF-130 143T-215T 4 1/4 10 3/8 16 13/16 10 13/16 13 3/4 14 7/16 11 9/16 15 1/4
HDAF-150 143T-215T 4 1/4 11 3/8 17 9/16 11 3/4 15 3/16 15 15/16 12 3/4 16 13/16
HDAF-160 143T-256T 4 1/4 12 1/2 18 5/16 12 11/16 16 11/16 17 1/2 14 18 7/16
HDAF-180 143T-326T 4 3/16 13 7/8 19 1/4 13 13/16 18 7/16 19 7/16 15 1/2 20 3/8
HDAF-200 182T-326T 4 3/16 15 1/4 10 1/16 14 15/16 20 1/4 21 1/4 17 22 3/8
HDAF-220 182T-326T 4 1/4 16 7/8 11 3/16 16 3/8 22 1/2 23 5/8 18 7/8 24 7/8
HDAF-240 213T-326T 6 1/4 18 9/16 12 5/16 18 13/16 24 3/4 26 20 3/4 27 3/8
HDAF-270 213T-326T 6 1/4 20 7/16 13 9/16 20 5/8 27 1/4 28 5/8 22 7/8 30 1/16
HDAF-300 213T-326T 6 1/4 22 3/4 15 1/8 22 5/8 30 3/8 31 7/8 25 1/2 33 9/16
For sizes 330 & 360, contact your local DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Cincinnati Fan sales representative.
* Includes optional inlet flange.
16 DISCHARGE POSITIONS AVAILABLE. 45° DISCHARGE POSITIONS NOT SHOWN.H
Discharges shown are determined by viewing fan from motor or drive side.

CW-TH CW-DB CW-BH CW-UB CCW-TH CCW-DB CCW-BH CCW-UB


Clockwise Top Clockwise Clockwise Clockwise Counter- Counter- Counter- Counter-
Horizontal Down Blast Bottom Up Blast Clockwise Top Clockwise Clockwise Clockwise
Up Blast
H
Discharge Discharge Horizontal Discharge Horizontal Down Blast Bottom

H
Discharge Discharge Discharge Horizontal Discharge
Discharge

H Not available on models HDAF-270 through HDAF-360 or any other models with discharge flange option without special
discharge extension. For arrangement 9CB units, contact your local Cincinnati Fan sales representative.

24
DIMENSIONS and SPECIFICATIONS
Arrangement #1 and #9, Belt Drive (specify 9R or 9L.)

BB C.
D.
C D F O P
Y Dia.Shaft For channel base
➀ Z Key Size, Sq. dimensions, see page 29.
Unit shown is Arrangement

S
O.D.

9R (motor on right side).


AA

For motor on left side,

M
specify Arrangement 9L.


DD

FF
R
3" H V
9/16 Dia. JJ
HH (6) Holes CW-BH
➀ ➀
J G ➁ MML➃ (Clockwise-Bottom Horizontal)
CC

À Add 1/8" for AMCA “C” Construction fans and/or


Á Add 1/4" for AMCA “C” Construction fans and/or
Down Blast discharge position.

 Discharge flange (not shown above) is standard on Models


Down Blast discharge position.
DISCHARGE

JJ
JJ

SHAFT & INLET

à MML IS MAXIMUM MOTOR LENGTH ON CUSTOMER SUPPLIED MOTOR.


HDAF-270 and HDAF-300. See page 31 for dimensions.
V

MOTOR MANUFACTURERS “C” DIMENSION CANNOT EXCEED “MML” WITH-


OUT A SPECIAL BASE.
➀ ➀ H NOTE: Housings are reversible and rotatable in 45° increments.
J G
Wheels are not reversible.
FOUNDATION PLAN

NOTE: For common boxed blower housing dimensions, see Page 22.
MODEL MOTOR ➀ Y Z ➁ ➁ ➃
NO. FRAME F G H V CL.II CL.IIP CL.III CL.II CL.IIP CL.III BB CC FF HH JJ MML
HDAF-120 56-215T 4 7 11/16 12 3/4 14 1 3/16 — — 1/4 — — 36 3/16 30 3/16 15 1/2 18 3/4 16 19 3/8
HDAF-130 56-256T 4 8 3/16 17 15 3/4 1 3/16 — — 1/4 — — 41 7/16 35 7/16 16 5/8 23 17 3/4 24 1/4
HDAF-150 56-256T 4 8 11/16 17 17 1/4 1 7/16 — — 3/8 — — 42 7/16 36 7/16 18 1/8 23 19 1/4 24 1/4
HDAF-160 56-256T 4 9 1/4 17 19 1/8 1 7/16 — — 3/8 — — 43 9/16 37 9/16 19 3/4 23 21 1/8 24 1/4
HDAF-180 145T-286T 4 9 15/16 18 1/2 21 1/2 1 7/16 1 11/16 — 3/8 3/8 — 46 7/16 40 7/16 22 3/4 24 1/2 23 1/2 26 3/8
HDAF-200 145T-286T 4 10 5/8 18 1/2 23 1/2 1 7/16 1 15/16 — 3/8 1/2 — 47 13/16 4113/16 23 1/2 24 1/2 25 1/2 26 3/8
HDAF-220 145T-324T 5 11 7/16 21 26 1/8 1 7/16 1 15/16 — 3/8 1/2 — 52 15/16 45 15/16 26 1/4 27 28 1/8 29 1/2
HDAF-240 145T-324T 6 12 5/16 21 281/4 1 11/16 2 3/16 — 3/8 1/2 — 57 5/8 47 5/8 28 1/2 27 30 3/4 29 1/2
HDAF-270 182T-324T 6 13 1/4 21 31 1 11/16 — 2 3/16 3/8 — 1/2 59 1/2 49 1/2 31 1/4 27 33 3/4 29 1/2
HDAF-300 182T-364T 6 14 3/8 24 3/4 341/4 1 15/16 — 2 7/16 1/2 — 5/8 65 9/16 55 9/16 34 1/2 30 3/4 37 1/4 33 1/4
For HDAF-330 & 360 dimensions, see page 26. DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.

C.D. BELT CENTER DISTANCE DIMENSIONS IN INCHES. DANGER


MOTOR FRAME SIZE All fans & blowers
56-145T 182T-184T 213T-215T 254T-256T 284T-286T 324T-326T 364T shown have rotating
MODEL
MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX.
parts and pinch
HDAF-120 11 3/16 12 3/4 12 1/8 13 1/2 12 5/16 13 11/16 points. Severe
HDAF-130 11 1/8 12 11/16 12 13/16 14 3/8 13 1/8 14 11/16 13 7/16 14 13/16 personal injury can
HDAF-150 11 5/8 13 3/16 13 7/16 14 15/16 13 7/8 15 5/8 14 5/16 16 result if operated
without guards. Stay
HDAF-160 12 3/16 13 11/16 14 15 1/2 15 1/8 17 3/16 15 11/16 17 5/8 away from rotating
HDAF-180 12 7/8 14 3/8 14 9/16 16 1/16 15 13/16 17 11/16 17 1/2 19 11/16 17 13/16 19 3/16 equipment unless it
HDAF-200 12 5/8 14 1/4 14 1/4 15 7/8 15 5/8 17 1/2 17 1/4 19 9/16 18 1/8 20 13/16 is disconnected
HDAF-220 13 9/16 15 1/16 15 3/16 16 5/8 16 7/16 18 3/16 18 1/8 20 1/4 19 1/4 21 3/4 20 3/4 22 9/16 from its power
source.
HDAF-240 13 11/16 15 3/16 15 7/16 16 15/16 16 11/16 18 9/16 18 1/2 20 11/16 19 7/16 22 21 5/16 24 3/8
Read operating
HDAF-270 16 17 1/2 17 5/16 19 3/16 19 21 1/4 20 1/16 22 /16 21 15/16
11 25 1/16 instructions.
HDAF-300 15 15/16 17 5/16 17 15/16 19 3/4 19 9/16 21 11/16 20 5/8 23 1/8 22 7/16 25 1/2 23 15/16 27 3/8
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
25
DIMENSIONS and SPECIFICATIONS
HDAF-330 & 360, Arrangement #1 and #9, Belt Drive (specify 9R or 9L)
BOTH SIDES: SIZE, QUANTITY AND LOCATION OF
SUPPORT ANGLES VARY WITH FAN ORIENTATION,
➁ HDAF-330 & 360 ONLY.
BB
O P
➀ C D F
C.
D.
Y Dia. Shaft
Z Key Size, Sq.

S
For channel base dimensions,
AA O.D.

see page 30.


Unit shown is Arrangement 9R

M

(motor on right side).

DD

R
FF
For motor on left side, specify
Arrangement 9L.

3 1/2" H V
3/4" Dia.
HH (6) Holes JJ
➀ ➀ KK
INLET SIDE
CW-BH
J G ➃MML ➅ PLATE

CC➁ (Clockwise-Bottom Horizontal)

NOTE: HDAF-330 AND 360 are not rotatable or reversible.


À Add 1/8" for AMCA “C” Construction fans and/or
HDAF-330 & 360 ONLY
INLET SIDE PLATE

Á Add 1/4" for AMCA “C” Construction fans and/or


Down Blast discharge position.
DISCHARGE

SHAFT & INLET

 Discharge flange (shown above) is standard on Models


Down Blast discharge position.
JJ
V
JJ
➅KK

à MML IS MAXIMUM MOTOR LENGTH ON CUSTOMER SUPPLIED


HDAF-330 and HDAF-360. See page 31 for dimensions.

J➀ G➀ H MOTOR. MOTOR MANUFACTURERS “C” DIMENSION CANNOT

Å
FOUNDATION PLAN EXCEED “MML” WITHOUT A SPECIAL BASE.
Inlet side plate width for HDAF-330 & 360.
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.

MODEL MOTOR ➀ Y Z
FRAME F G H V CL.II CL.III CL.II CL.III FF HH JJ KK
HDAF-330 182T-365T 6 15 15/16 25 28 2 3/16 2 7/16 1/2 5/8 66 1/8 59 15/16 38 3/4 32 30 41 3/4 33
HDAF-360 182T-365T 6 17 1/8 25 31 2 7/16 2 11/16 5/8 5/8 681/2 62 5/16 42 32 33 45 33

C.D. BELT CENTER DISTANCE


Note: For common boxed blower housing MOTOR CLASS II & III
dimensions, see Page 22. FRAME MIN. MAX.
182T-184T 17 9/16 18 5/8
213T-215T 18 7/8 20 5/16
254T-256T 20 9/16 22 5/16
284T-286T 21 9/16 23 11/16
324T-326T 23 1/2 26 1/16
364T-365T 24 15/16 28

16 DISCHARGE POSITIONS AVAILABLE. 45° DISCHARGE POSITIONS NOT SHOWN.H


Discharges shown are determined by viewing fan from motor or drive side.

CW-TH CW-DB CW-BH CW-UB CCW-TH CCW-DB CCW-BH CCW-UB


Clockwise Top Clockwise Clockwise Clockwise Counter- Counter- Counter- Counter-
Horizontal Down Blast Bottom Up Blast Clockwise Top Clockwise Clockwise Clockwise
Discharge Discharge Horizontal Discharge Horizontal Down Blast Bottom Up Blast

H
Discharge
H
Discharge Discharge Discharge Horizontal
Discharge
H Not available on models HDAF-270 through HDAF-360 or any other models with discharge flange option without special
discharge extension. For arrangement 9CB units, contact your local Cincinnati Fan sales representative.
26
DIMENSIONS and SPECIFICATIONS
Arrangement #8, Direct Connected

BB

Y Dia.Shaft
➀ C D E Z Key Size, Sq. O P
SHAFT/COUPLING
GUARD, STD.

S
O.D.
AA

M
DD

FF
3" H H V
HH 9/16 Dia. JJ
➀ ➀ CW-BH
J G (8) Holes
Clockwise-Bottom Horizontal)

CC

À Add 1/8" for AMCA “C” Construction fans and/or Down Blast
Á Add 1/4" for AMCA “C” Construction fans and/or
discharge position.
DISCHARGE

SHAFT & INLET


JJ

JJ
V

 Discharge flange (not shown above) is standard on Models


Down Blast discharge position.

HDAF-270 and HDAF-300. See page 31 for dimensions.


➀ ➀ H H
NOTE: Housings are reversible and rotatable in 45° increments.
J G Wheels are not reversible.
FOUNDATION PLAN

NOTE: For common boxed blower housing dimensions, see Page 22.
MODEL MOTOR ➀ Y Z ➁ ➁
NO. FRAME E G H V CL.II CL.IIP CL.III CL.II CL.IIP CL.III BB CC FF HH JJ
HDAF-120 143T-184T 15 5/8 17 11/16 16 14 1 3/16 – – 1/4 – – 51 7/16 49 7/16 15 1/2 38 16
HDAF-130 143T-215T 15 5/8 18 3/16 16 15 3/4 1 3/16 – – 1/4 – – 52 7/16 50 7/16 16 5/8 38 17 3/4
HDAF-150 143T-215T 15 5/8 18 11/16 16 1/2 17 1/4 1 7/16 – – 3/8 – – 54 7/16 52 7/16 18 1/8 39 19 1/4
HDAF-160 143T-256T 15 5/8 19 1/4 16 1/2 19 1/8 1 7/16 – – 3/8 – – 55 9/16 53 9/16 19 3/4 39 21 1/8
HDAF-180 143T-286T 15 5/8 19 15/16 18 9/16 21 1/2 1 7/16 — 1 11/16 3/8 — 3 /8 61 1/16 59 1/16 22 3/4 43 1/8 23 1/2
HDAF-200 182T-324T 15 5/8 10 5/8 18 9/16 23 1/2 1 7/16 — 1 15/16 3/8 — 1/2 62 7/16 60 7/16 23 1/2 43 1/8 25 1/2
HDAF-220 182T-324T 17 5/8 11 7/16 21 1/8 26 1/8 1 7/16 — 1 15/16 3/8 — 1/2 69 3/16 67 3/16 26 1/4 48 1/4 28 1/8
HDAF-240 213T-324T 17 5/8 12 5/16 21 1/8 281/4 1 11/16 — — 3/8 — — 72 7/8 68 7/8 28 1/2 48 1/4 30 3/4
HDAF-270 213T-324T 19 5/8 13 1/4 23 5/8 31 1 11/16 — — 3/8 — — 79 3/4 75 3/4 31 1/4 53 1/4 33 3/4
HDAF-300 213T-324T 19 5/8 14 3/8 23 5/8 341/4 1 15/16 — 2 7/16 1/2 — 5/8 82 1/16 78 1/16 34 1/2 53 1/4 37 1/4
For HDAF-330 and HDAF-360 dimensions, contact DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
your local Cincinnati Fan Sales Representative.

Construction Gauges
Inlet Bearing Wheel (All Classes)
Fan Side Inlet & Motor Airfoil Back Reinf.
Size Housing Plate Bell Base Shroud Blades Plate Plate
120 10 10 14 10 12 16 7 10
130 10 10 14 10 12 16 7 10
150 10 10 14 10 12 16 7 10
160 10 10 14 10 12 16 7 10
180 10 10 14 10 12 16 7 10
200 10 10 14 10 12 16 7 10
220 10 10 14 10 12 16 7 10
240 10 7 14 7 11 16 7 10
270 10 7 14 7 11 16 1/4" 1/4"
300 10 7 14 7 11 16 1/4" 1/4"
330 * 7 14 * 10 16 1/4" 1/4"
360 * 7 13 * 10 16 1/4" 1/4"
*Varies with class and arrangement, contact your local Cincinnati Fan sales representative.
27
DIMENSIONS and SPECIFICATIONS
Arrangement #10, Belt Drive

BB
3"
C D O P
F

Y Dia.Shaft

S
Z Key Size, Sq.
O.D.
AA

M
C.D.

R
DD

FF
➀ ➀G 3" V
J H JJ
HH
➁CC
9/16 Dia. CW-BH
MML
➃ (6) Holes (Clockwise-Bottom Horizontal)

À Add 1/8" for AMCA “C” Construction fans and/or


Á Add 1/4" for AMCA “C” Construction fans and/or
Down Blast discharge position.

 Discharge flange (not shown above) is standard on Models


Down Blast discharge position.
DISCHARGE

JJ
JJ

SHAFT & INLET

à MML IS MAXIMUM MOTOR LENGTH ON CUSTOMER SUPPLIED


HDAF-270 and HDAF-300. See page 31 for dimensions.
V

MOTOR. MOTOR MANUFACTURERS “C” DIMENSION CANNOT


EXCEED “MML” WITHOUT A SPECIAL BASE.
➀ ➀ NOTE: Housings are reversible and rotatable in 45° increments.
J G H Wheels are not reversible.
FOUNDATION PLAN

NOTE: For common boxed blower housing dimensions, see Page 22.
MODEL MOTOR ➀ Y Z ➁ ➁ ➃
NO. FRAME F G H V CL.II CL.IIP CL.III CL.II CL.IIP CL.III BB CC FF HH JJ MML
HDAF-120 56-184T 4 1/8 17 11/16 12 3/4 14 1 3/16 — — 1/4 — — 36 3/16 30 3/16 15 1/2 18 5/8 16 18 7/8
HDAF-130 56-184T 4 1/8 18 3/16 17 15 3/4 1 3/16 — — 1/4 — — 417/16 35 5/16 16 5/8 22 7/8 17 3/4 23 1/8
HDAF-150 56-215T 4 1/8 18 11/16 17 17 1/4 1 7/16 — — 3/8 — — 42 7/16 36 5/16 18 1/8 22 7/8 19 1/4 24 1/4
HDAF-160 56-215T 4 1/8 19 1/4 17 19 1/8 1 7/16 — — 3/8 — — 43 9/16 37 7/16 19 3/4 22 7/8 21 1/8 24 1/4
HDAF-180 56-256T 4 1/8 19 15/16 18 1/2 21 1/2 1 7/16 1 11/16 — 3/8 3/8 — 46 7/16 40 5/16 22 3/4 24 3/8 23 1/2 26 5/8
HDAF-200 56-256T 4 1/8 10 5/8 18 1/2 23 1/2 1 7/16 1 15/16 — 3/8 1/2 — 47 13/16 4111/16 23 1/2 24 3/8 25 1/2 26 5/8
HDAF-220 145T-286T 5 1/8 11 7/16 21 26 1/8 1 7/16 1 15/16 — 3/8 1/2 — 52 15/16 45 13/16 26 1/4 26 7/8 28 1/8 29 3/4
HDAF-240 145T-324T 6 3/16 12 5/16 21 281/4 1 11/16 2 3/16 — 3/8 1/2 — 57 5/8 47 7/16 28 1/2 26 13/16 30 3/4 29 5/8
HDAF-270 182T-324T 6 3/16 13 1/4 21 31 1 11/16 — 2 7/16 3/8 — 5/8 59 1/2 49 5/16 31 1/4 26 13/16 33 3/4 29 5/8
HDAF-300 182T-324T 6 3/16 14 3/8 24 3/4 341/4 1 15/16 — 2 7/16 1/2 — 5/8 65 9/16 55 3/8 34 1/2 30 9/16 37 1/4 33 3/8
HDAF-330 and HDAF-360 are not available in Arrangement 10. DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.

C.D. BELT CENTER DISTANCE DIMENSIONS IN INCHES DANGER


56 143T-145T 182T-184T 213T-215T 254T-256T 284T-286T 324T All fans & blowers
MODEL MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. shown have rotating
HDAF-120 18 1/8 10 18 1/8 10 17 1/2 19 parts and pinch
points. Severe
HDAF-130 19 1/4 11 1/8 19 1/4 11 1/8 18 3/8 10 1/8 personal injury can
HDAF-150 10 12 1/8 10 12 1/8 19 1/8 11 1/8 18 3/8 10 3/8 result if operated
HDAF-160 11 5/8 13 5/8 11 5/8 13 5/8 10 5/8 12 5/8 10 11 7/8 without guards. Stay
HDAF-180 14 16 1/8 14 16 1/8 12 3/4 15 1/8 12 14 3/8 111/8 13 3/8 away from rotating
equipment unless it is
HDAF-200 14 3/4 16 7/8 14 3/4 16 7/8 13 1/2 15 7/8 12 3/4 15 1/8 11 13 disconnected from its
HDAF-220 17 19 3/4 16 1/8 18 5/8 15 3/8 17 7/8 14 3/8 16 7/8 13 3/4 16 1/4 power source.
HDAF-240 191/4 22 18 1/4 21 17 5/8 20 1/8 16 5/8 19 1/8 15 7/8 18 3/8 14 7/8 17 3/8 Read operating
HDAF-270 21 23 3/4 20 3/8 22 7/8 19 3/8 217/8 18 5/8 21 1/8 17 5/8 20 1/8 instructions.
HDAF-300 24 1/4 26 7/8 23 1/2 26 1/8 22 1/2 25 1/8 21 7/8 24 3/8 20 7/8 23 3/8
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
28
DIMENSIONS and SPECIFICATIONS
HDAF-180 to 300, Arrangement #9RCB or #9LCB Channel Base, Belt Drive
For HDAF-330 & 360, Arrangement 9CB, see page 30.

C.D Unit shown is


.
Arrangement 9RCB
(motor on right
side).
For motor on left
side, specify
Arrangement 9LCB.

Channel base
arrangements not
available with Down
6" Blast or 45° Bottom
Angular Down
J ➄ discharge fan
U
➀ 9/16 Dia.
positions.
1" G 1" 5" V V 5"
(6) Holes
CC JJ

Note: For blower dimensions, see Pages 22 and 25.

MOTOR ➀ ➄
MODEL FRAME G J U V CC JJ
HDAF-120 184T-215T 28 3/16 5 3/4 3 13 15/32 30 3/16 36 15/16
HDAF-130 184T-256T 33 7/16 6 1/4 3 7/8 15 13/16 35 7/16 41 5/8
HDAF-150 184T-284T 34 7/16 6 3/4 4 5/8 17 3/4 36 7/16 45 1/2
HDAF-160 184T-286T 35 9/16 7 5/16 5 9/16 18 11/16 37 9/16 47 3/8
HDAF-180 184T-324T 38 7/16 18 16 3/4 21 3/16 40 7/16 52 3/8
HDAF-200 254T-324T 39 13/16 18 11/16 17 3/4 22 3/16 41 13/16 54 3/8
HDAF-220 254T-364T 43 15/16 19 1/2 19 1/16 26 11/16 45 15/16 63 3/8
HDAF-240 254T-364T 48 1/8 10 11/32 10 3/8 28 50 1/8 66
HDAF-270 254T-364T 50 11 9/32 11 7/8 29 1/2 52 69
HDAF-300 254T-364T 56 1/16 12 7/16 13 5/8 31 1/4 58 1/16 72 1/2
➀ Add 1/8" for AMCA “C” Construction.
➂ Discharge flange (not shown above) is standard on Models HDAF-270
and HDAF-300. See page 31 for dimensions.
➄ Subtract 1/8" for AMCA “C” Construction.
C.D. BELT CENTER DISTANCE DIMENSIONS IN INCHES
184T 213T-215T 254T-256T 284T-286T 324T-326T 364T
MODEL MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX.
HDAF-120 23 5/8 25 7/8 21 15/16 24 11/16
HDAF-130 27 1/2 29 5/8 25 7/8 28 5/8 23 15/16 27 3/16
HDAF-150 31 33 29 5/16 32 1/8 27 3/8 30 5/8 25 15/16 29 11/16
HDAF-160 32 5/8 34 13/16 30 7/8 33 9/16 28 7/8 32 1/16 27 7/16 31 1/16
HDAF-180 37 1/4 39 1/4 35 5/8 38 1/4 33 5/8 36 11/16 32 1/8 35 3/4 29 13/16 34 1/8
HDAF-200 34 13/16 37 15/16 33 3/8 36 15/16 31 1/16 35 5/16
HDAF-220 42 15/16 46 1/16 41 1/2 45 1/8 39 3/16 43 1/2 37 3/16 42 3/16
HDAF-240 45 1/8 48 3/16 43 11/16 47 3/16 41 5/16 45 9/16 39 5/16 44 1/4
HDAF-270 47 3/4 50 3/4 46 1/4 49 3/4 43 15/16 48 1/16 4115/16 46 3/4
HDAF-300 50 7/8 53 13/16 49 7/16 52 13/16 47 1/16 511/8 45 1/16 49 3/4
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.

29
DIMENSIONS and SPECIFICATIONS
HDAF-330 & 360, Arrangement #9RCB or #9LCB Channel Base, Belt Drive

BOTH SIDES: SIZE, QUANTITY AND LOCATION OF


SUPPORT ANGLES VARY WITH FAN ORIENTATION.

Unit shown is
Arrangement 9RCB
C.
D. (motor on right side).
For motor on left side,
specify Arrangement
9LCB.

➂ Channel base
arrangements not
available with Down
Blast or 45° Bottom
3/4" Dia. Angular Down
8 Holes discharge fan positions.

6"
J ➄ U
1" LL LL 1" 5" V V 5"
CC JJ

NOTE: For blower dimensions, see Pages 22 and 26.


NOTE: Models HDAF-330 & 360 are not rotatable or reversible in the field.

MOTOR ➄ ➂ Discharge flange is standard on


MODEL FRAME J U V CC JJ LL Models HDAF-330 and HDAF-360.
HDAF-330 182T-444T 14 1/2 10 32 11/16 62 7/16 75 3/8 30 7/32 See page 31 for dimensions.
HDAF-360 182T-444T 15 11/16 11 1/2 32 11/16 64 13/16 75 3/8 31 13/32 ➄ Subtract 1/8" for AMCA “C” Construction.
Dimensions subject to change without notice.
C.D. BELT CENTER DISTANCE
182T-184T 213T-215T 254T-256T 284T-286T 324T-326T 364T-365T 404T-405T 444T
MODEL MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX.
HDAF-330 62 3/8 64 3/8 60 11/16 63 1/8 58 5/8 61 9/16 57 3/16 60 1/2 54 13/16 58 13/16 52 13/16 57 7/16 53 1/8 58 13/16 51 9/16 57 11/16
HDAF-360 62 15/16 64 7/8 61 1/4 63 9/16 59 3/16 62 57 3/4 60 15/16 55 5/16 59 3/16 53 5/16 57 13/16 53 1/2 59 51 7/8 57 13/16
Dimensions subject to change without notice.

Fan base support angle (above) is attached to


front and rear of fan base/channel base for extra
rigidity on sizes 330 & 360.
30
DIMENSIONS and SPECIFICATIONS
INLET AND OUTLET FLANGES

INLET

3/16" C

O.D. INLET
O.D.

B.C.

AA
A

B
“P” Dia.
“N” No. of holes
Typ.

D 3/16"
OUTLET*
* Not available on: Down Blast, Top
G

Angular Down, or Bottom Angular


Down fan discharge positions, for
H SPACES — J.O.C.

any models, without a discharge


extension. Outlet flange standard
DD

on all HDAF-270 to HDAF-360.


F

Dimensions shown below are for


100% width housings. For partial
width housings, contact your
local Cincinnati Fan sales repre-
sentative.
Typ. G 7/16 Dia.
K SPACES–L.O.C.
“M” No. of holes
NOTE: Flanges will be drilled
E
unless otherwise specified.
DIMENSIONS IN INCHES ± 1/16” ** DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.

MODEL A B C➀** D ** E F G H J K L M N P AA** DD**

HDAF-120 16 14 3/8 4 1/16 19 3/8 13 3 /8 17 11/16 1 2 7 27/32 2 5 11/16 8 8 7/16 13 1/4 13 3/4
HDAF-130 17 3/4 15 15/16 4 1/16 10 3/8 14 3/8 19 3/16 1 2 8 19/32 2 6 3/16 8 8 7/16 14 5/8 15 1/4
HDAF-150 19 1/4 17 1/2 4 1/16 11 3/8 15 3/8 20 3/4 1 3 6 1 /4 2 6 11/16 10 8 7/16 16 1/8 16 13/16
HDAF-160 21 1/8 19 3/8 4 1/16 12 1/2 16 1/2 22 7/16 1 3 6 13/16 2 7 1/4 10 8 7/16 18 18 7/16
HDAF-180 23 1/2 21 1/2 4 1/16 13 7/8 17 7/8 24 1/2 1 3 7 1 /2 2 7 15/16 10 12 7/16 20 20 3/8
HDAF-200 25 1/2 23 1/2 4 1/16 15 1/4 19 1/4 26 3/8 1 3 8 1 /8 3 5 3/4 12 12 7/16 22 22 3/8
HDAF-220 28 1/8 26 1/8 4 1/16 16 7/8 20 15/16 28 7/8 1 4 6 23/32 3 6 5/16 14 12 7/16 24 5/8 24 7/8
HDAF-240 30 3/4 28 3/4 6 1/16 18 9/16 22 5/8 31 3/8 1 4 7 11/32 3 6 7/8 14 16 7/16 27 27 3/8
HDAF-270 33 3/4 31 5/8 6 1/16 20 7/16 24 1/2 34 1/8 1 4 8 1/32 3 7 1/2 14 16 7/16 30 30 1/16
HDAF-300 37 1/4 35 1/4 6 1/16 22 3/4 26 3/4 37 5/8 1 5 7 1 /8 3 8 1/4 16 16 7/16 33 1/2 33 9/16
★HDAF-330 40 3/8 38 3/4 6 1/16 24 7/8 28 7/8 40 7/8 1 7 5 9/16 5 5 3/8 24 16 1/2 36 3/4 36 7/8
★HDAF-360 43 5/8 42 6 1/16 27 1/4 31 1/4 44 1/4 1 7 6 1/32 5 5 27/32 24 16 1/2 40 40 1/4
➀ Add 1/8" for AMCA “C” Construction fans and/or Downblast discharge position. ** NOTE: Dimensions C, D,
★ HDAF-330 & 360 HAVE FIXED HOUSINGS AND ARE THEREFORE NOT ROTATABLE IN THE FIELD. AA and DD are ±1/8”.