0 ratings0% found this document useful (0 votes) 1K views21 pagesSAP2000 Link - IDEA StatiCa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here.
Available Formats
Download as PDF or read online on Scribd
arzar2020
‘SAP2000 link |IDEA Siatica
IDEA StatiCa Tutorial - SAP2000 link
This tutorial will show how to activate and use the link between SAP2000 and IDEA
StatiCa Connection.
Ne
Known
Use the link Update the project
limitations
1 How to activate the link
Install the latest version of IDEA StatiCa, get it in the Downloads
Make sure you are using a supported version of SAP2000 — updates are published in
the BIM section
IDEA StatiCa automatically integrates the BIM link into your CAD/CAE software
during its installation. You can check the status and activate more BIM links for later
installed software in the BIM link installer.
Open IDEA StatiCa and navigate to the panel BIM and open the BIM link installer.
A notification "Run as administrator” may appear, please confirm with the Yes button
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm wasarzar2020
‘SAP2000 link |IDEA Siatica
a
fs)? op ae IL)
cod eee eae
IDEA StatiCa is a part of your workflow
Speed up your analysis and design process by
FEA and CAD prox
=a (SEs
open
Stseng provece
Pee a
Select the software to integrate the IDEA StatiCa BIM link, click the Install button
and check the Installed status.
Do you need support?
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him
221arzar2020
Gy rece vesgn 201
IM tex 20171
Im te 2016;
TA, vce wea 2010
TA, voce seo 2017
owt 2078
SCH Enginoor
STAD Pro vai
le
ai on
2 ors
Be 7 > ak KR ME
abot Seructural Analyse
‘SAP2000 link |IDEA SlatiCa
StatiCa’ Colculete yesterday's estimates
7
Start SAP2000. In menu Tools and Add/Show Plugins fill the Plugin Name field as
follows:
SAP2000v20Plugin_IDEA_Conneetion (in Version 20)
SAP2000v21Plugin_IDEA_Connection (in Version 21)
Then type in the Menu Text (command name displayed in the menu) and click Add,
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him
Do you need support?
21‘SAP2000 link |IDEA Silica
arzar2020
7M citemel Pugin Date
curent Pugs
aa
A <>)
[serzovnyzirugn_oeA comecton —[SAPz000vzIPugn DEA comecto]OK
'3A?2000,20Fuph DEA Connection |SA°2000,20FWoh DEA Come. |OX
2 How to use the link
Open the attached project in SAP2000 and run the CBFEM analysis
in_IDEA_Connection .or
Go to menu item Tools and choose SAP2000v20Plugli
IDEA_Connection
SAP2000v21Plugin,
8{ sr92100.2000 Unimate oe Sarno
Fle Et View Define aw Select Astgn Anne Diplay Design Options [Tos
QQ QAR’ 8p 94 7 2 yz AdeiShow Prins.
cy
x
s
a
B
e
a
Bevan
0) a i
ES Xt
Do you need support?
42s
32_Sleel/Tutoriale/BIM/SAPZ000/SAP2000_lnk him
ntps:lresources [Link]/Contanv0:Statica
arzar2020 'SAP2000 lnk [I
A wizard window is opened, select the join you want to transfer to IDEA StatiCa
Connection and click on ECEN.
DY Me 20 7D ARARA BY ye WM 261
=a
eed
<
: nan et we) ro
Finally, we click Connection design to directly start IDEA StatiCa Connection.
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him
Do you need support?
521arzar2020 ‘SAP2000 lnk [I
Statica
StatiCa® connecron
eed
Connection design needs more dat to be able to provide a proper design according to national codes You can use defauit settings or
afin hem thi war,
Design cok iN
“ype of structure: General structure os
Default setting:
load combinations ae sed forthe design
Load combination are sorted nt classes ULS,SLS ete
(Con [Link] NI sE1re2
Connected members
ous TeaIPERO (FED) || Seminar [coninnss
37120eN 4070/20 [fee] [Eaten
[Erjareauentsavto 2008 aha _—
srs 2updanta
sr 2UPNA0rOr
Konmecionoeign it ana
3 Design
We right-click on Operation in the tree menu to add a New operation and select
Stiffening plate.
\
LN D0) 120) SUP Ort?
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him 621arzar2020 'SAP2000 link |IDEA Statica
Ee
4 Members
¥ Dut
¥ 371 2uUPN140/10/
Y 372 2uPNt40/10/
4 Load effects
‘COMBO_DEAD
siRIa
smRis
TRIG
sTRIT
sTRIB
sTRIO
sTR20
‘oKer
aKe2
PIR RK KRRKRKEKRKE
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm masarzar2020 'SAP2000 link IDEA Statica
Select operation x
EVAB!
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm
ansarzar2020 'SAP2000 link |IDEA Statica
In the same way we add the manufacturing operation Cut and fill in the values below.
Select operation x
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htmarzar2020 ‘SAP2000 link IDEA Statica
ee RT =n
cy don soot
‘mm
In the next step, right-click on Operation CUT1 and select Copy. Then change the
value for Member to 372
% Delete
T Rename
angrier
Comazine (-Comt
Oreinn) 2
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm s0121arzar2020 'SAP2000 link |IDEA Statica
Let's continue with input of manufacturing operation Bolt grid or contact. Values set
according picture.
Select operation x
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm swearzar2020 'SAP2000 link IDEA Statica
Bolt assembly x
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm
Do you need support?
ratarzar2020 ‘SAP2000 link IDEA Statica
Ps to :
Selena J
In the next step, right-click on Operation GRD1 and select Copy. Then change the
value for Item 1 type and Item 2 type to 372.
cunt
¥ cure
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm 9121arzar2020 ‘SAP2000 link IDEA Statica
=u ee
= :
4 Check
Nonlinear analysis is started by icon Calculate from the top ribbon. Analysis model is
automatically generated, calculation is performed and we can check results.
Activate Strain check, Equivalent stress, Mesh and Deformed from the ribbon to
get a full picture of what is happening in the joint. Everything is displayed in the 3D
window.
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm 1412arzar2020
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm
‘SAP2000 link |IDEA Siatica
All values can be reviewed in detailed in the tables and 2D window. For example to
display check of bolts select tab Bolts/Anchors tab.
Cheek of belts for extrame load effect
Ue) ik |
20109-11764 1983 980
20109-21764 2062980
5 Report
At last we go to the tab Report. IDEA StatiCa offers fully customizable report to print
‘out or save in editable format.
Do you need support?
mV foRe Jue Us Uns
soe |e RS To) KN) Pal Pada
Bi |meo10a-i|stri4@)|103 |azoyez2|z010 sa eae a0
w |aaviog-1 striag| 1a) | 7527752 2000 80767 ad
63 |wanioa-1/smriuq@|1s6 |e52/032 2000 88 643708
‘Tension resistance check (EN 1993-1-8 Tabi 34)
Fgg= Bish = 1764 IN 2 R= 158 kN
nee
fy =000 = Factor
‘f= 10000 MPa. - Utimae tense tena ofthe bot
45mm? —_— Tensile stress area of the bot
a " .
[FI] © |e |veots9-1 sraiscn]r2e | asaias 2000 73474526
fF], © |e [aorns-2 stra] ios [essye53 200 1 aro sta
[+] © |e6 |veoto9-2 smue|is1 |70/700 20:0 (74 796 48
FE] © [er [weoins-2/stmiaca) 25 |exiveni|zou0 [rr os Tas
[+l] @ |ee |veors9-2 sraue|t.6 |srzyar2 2000 71402533
Design data
Non FRG BpRa [Fura
19128arzar2020 ‘SAP2000 link IDEA Statica
We have imported a joint from SAP2000 and designed and code-checked it
according to Eurocode.
6 Synchronize models
StatiCa® coaecheck manager
ee es
Code-check manager is a BIM tool to export and synchronize connections from other
programs. It is launched directly in the 3rd party applications via a command/icon
Synchronize - IDEA StatiCa detects changes in already imported entities (changes
in thickness, changes in cross-section, modification of properties of welds, bolts, etc.)
and updates the project in IDEA StatiCa Connection.
Calculate - Synchronize and calculate current item and provide a new set of results.
Calculate all - Synchronize and calculate alll items and provide new set of results.
Note
Kindly be aware that IDEA StatiCa syncs with a model nf tha 2rd narhs annlinatinn,
not the other way around. If we add operations in IDE 0° YOu Need support? je
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him 162‘aarz020 'SAP2000 lnk IDEA Station
options described above (Synchronize; Modify; Calculate; Calculate all), the
additionally added operations will be deleted
We save the project in IDEA StatiCa and close the application Connection. Alll joints
exported from SAP2000 project to IDEA StatiCa are kept on the list inside SAP2000.
StatiCa® codecheck manager
ee es
Besauzcom © oats © roves
Pats © 205%
pots @ 914 «100%
Welds © 881 100%
Sucking © Notes
sare syconized wt
If we modify the project in SAP2000 (e.g. change cross section of any member or
add another loads) we can simply update the project in IDEA StatiCa without
modeling it all again. Let's change the cross section of one of the members.
First, we unlock the project in SAP2000.
Do you need support?
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him aniaarzar2020 'SAP2000 link |IDEA Statica
Right-click on the member 371 and following window appears. Go to Assignments
and change the cross-section from 2UPN140/10/ to 2UPN160/10/ and click OK.
1 bject Model - Line ntrmation x
“Mesh Option ‘Atiniermediate Joints |
‘oube cick wie tacigrourd Caio eat em.
oS
We repeat the same for the Member 372 as well, Run the analysis, select
SAP2000v20Plugin_IDEA_Connection in the upper “” oo ec
Do you need support?
manager click on Synchronize. 2 i
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm 1012arzar2020
er)
ee
ue 216
se ‘ci
In the next window just select Connection design.
StatiCa® connecron
eee rd
Connacton design aces more dat to be able to provide a proper design secoring to national codes, You can use dafaut settings or
cline them inthis war,
Design code: en
Type of structure: General structure
Default eating:
‘load combination ae uae forthe dion,
Load combinations are sored nt classes ULS,SLS ete
‘con [Link] NI SE e240
connected members
> | APEIO(PEDA) [Ale Rewnges [cntnom
ariavenieoo/ au |gfp eg
[Dilsrs aurea au pa 2
Do you need support? _
[Link]/ContentO2_Sleel/Tutoriale/BIM'SAPZ000/SAP2000_lnk him
1972arzar2020
‘SAP2000 link |IDEA Siatica
As you can see, the cross-section of the Members 371 and 372 has changed, but all
previous operations remained
vous
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm
7 Known limitations
Link now works for a wide variety of connections/joints. However, please take into
account yet unsupported functionality
Eccentricity - Centroid is not set as Cardinal point
lia Jn
7] enscearetom rane afince orf
fenentadtrren? toss
| Pose Dstauts |
ea] feed Geer
Workaround: Import the whole joint and manually move the beams with
eccentricity to the proper position, Do you need support?
2012+‘aarz020 'SAP2000 lnk IDEA Station
Keywords.
connection, joint, Eurocode, bevel, cut, stub, SAP2000, BIM, BIM link, code-check
manager, CBFEM
Related articles and tutorials:
IDEA StatiCa tutorial — How to combine Tekla Structures and SAP2000
Do you need support?
Intps:lresources [Link]/ConlanU02_StooV/Tutorials/BIM/SAPZ000/SAPZ000_ink htm aes