Specifications for S20 High-Performance Color System
THE PIONEER OF COLOR DOPPLER ULTRASOUND IN CHINA
Product Overview
Specifications for S20 High-Performance Color System
General Specification z Cardiology
The high performances of the SonoScape z Obstetrical
S20 stem from the advanced ultrasound z Gynecological
Doppler imaging technologies that include z Musculoskeletal
full digital beam-former, wide dynamic range, z Vascular
multi-beam processing, Modularized z Urological
touchscreen human-machine interaction z Small Parts And Superficial
system etc. z Pediatric
The ergonomic user-friendly design enables z Anaesthesia
user to customize the system according to
the specific application needs, and the Scanning Methods
graphic exam icon assure you familiar with z Electronic Convex Sector
the system in few minutes. z Electronic Linear
z Electronic Phased Array Sector
Advanced Technologies
z Digital Front-End Sweep Angle
z Dual-Beam Processing z Curved Probe:70 degree or more
z Compound Imaging z Phased Array Probe:90 degree or more
z Micro Scan Processing z Micro-curved Probe:193 degree or more
z Harmonic Imaging
z High Pulse Repetition Frequency Transducer Types
z Panoramic Imaging z Convex Array
z 4D Imaging z Micro convex Array
z Graphic Exam Icon z Linear Array
z Modularized touchscreen human-machine z Phase Array
interaction technology
Operating Modes
System Overview z B-Mode
Applications z M-Mode
z Abdominal z TDI-Mode
901-00122
Page 4 of 17
Specifications for S20 High-Performance Color System
z Color Flow Mode(CFM) z Frame Rate: 750 frames/sec or more
z Power Doppler Imaging(PDI) z Display Gray Scale:256 levels
z Pulse Wave Doppler(PWD) z Digital Channel Number:1024
z Continuous Wave Doppler(CWD) z Probe Elements: Up to 256
z 3D/4D Imaging
z Color M Mode Media &Peripherals
z Steer M-Mode z Color Desk Jet Pinter(optional)
z B/W Video Pinter(optional)
Display Modes z Color Video Pinter(optional)
z Gray-scale imaging
z Color: Color Doppler, Power Flow and System Menu Setting
Directional Power Flow Imaging, TDI z File Manager
z THI(Tissue Harmonic Image) →Copy、Paste、Delete
z Dual B, Quad Display →Convert PC
z B and M, display format selectable →Report Only
z B and Doppler →Image Only
z B+Color →Search
z Dual B(Flow) →Select All
z Triplex mode: B, Flow, and PW/CW →Send DICOM
Doppler →DICOM Print
z B, Flow, and Color M z Set Time/Date
z Simultaneous Refresh Display z Facility Name
z Variable screen size: Change the screen z Dicom
ratio of 2D and Doppler/M in duplex or z System Information
triplex mode →Control Number
z Panoramic Imaging →Software Version
z Compound Imaging z System Setting
z Trapezozd Imaging →General Setting
Language Setting
Standard Features ¾ English
901-00122
Page 5 of 17
Specifications for S20 High-Performance Color System
Screen Saver Video Invert
Trackball Sensitive Insert Driver
Clip Format →Set Calculation Menu
¾ CIN 2D Mode
¾ WMV ¾ Angle
¾ AVI ¾ Volume
Date Format ¾ Volume L×W×H
¾ mm/dd/yyyy ¾ Doppler Area
¾ yyyy/mm/dd ¾ Vascular
¾ dd/mm/yyyy ¾ Small Part
Caps Lock:on/off ¾ Obstetrical/ Gynecological
Print Size ¾ Left Ventricle
Still Format ¾ Urologic
¾ PPM ¾ Mitral Valve Diam
¾ JPG ¾ Lv Outflow Diam
¾ BMP ¾ Pul.Valve Diam
¾ TIF PW Mode
Color of ROI ¾ Flow Velocity
¾ Green ¾ Acceleration
¾ Yellow ¾ Time
¾ Orange ¾ Heart Rate
¾ Cyan ¾ Cardiac
Display Format ¾ Obstetrical/ Gynecological
¾ H1/2、H1/4、V1/3 ¾ Vascular
¾ V1/2、V2/3、O1/4 M Mode
One key Save:on/off ¾ Distance
EFW Unit:kg,g、Ib,oz ¾ Time
Print to DICOM ¾ Slope
→Set Printer ¾ Heart Rate
Printer Driver ¾ left Ventricle
901-00122
Page 6 of 17
Specifications for S20 High-Performance Color System
¾ Mitral Valve ¾ Mediscan BPD,AC
¾ Aortic Valve BPD Method
→Set Measurement Method ¾ Hadlock
BSA setting ¾ Jeanty
¾ Eastern ¾ Crespigeny
¾ Western ¾ Kurtz
Measure Method ¾ Hansmann
¾ Ellipse ¾ Sabbagha
¾ Trace ¾ Campbell
Package ¾ Tokyo
¾ All Package ¾ Merz
¾ Icon Driven ¾ Osaka
Continue Dist:on/off FL Method
Dop Auto ¾ Hadlock
¾ AUTO ¾ Hohler
¾ SEMI-AUTO ¾ Jeanty
Focal Auto:on/off ¾ Hansmann
EFW Method ¾ Tokyo
¾ WEI/SAB HC,AC,FL ¾ Merz
¾ Shepard AC,BPD ¾ Chitty
¾ Hadlock1 AC,FL ¾ Osaka
¾ Hansman AC,FL,HC ¾ Campbell
¾ Tokyo BPD,APTD,TTD,FL CRL Method
¾ Hadlock2 HC,AC,FL ¾ Robinson
¾ Hadlock3 BPD,AC,FL ¾ Hadlock
¾ Hadlock4 HC,AC ¾ Nelson
¾ Hadlock5 BPD,HC,AC,FL ¾ Jeanty
¾ Shinozuka BPD,AC,FL ¾ Hansmann
¾ Warsof FL,AC ¾ Mediscan
¾ Mediscan FL,AC ¾ Tokyo
901-00122
Page 7 of 17
Specifications for S20 High-Performance Color System
¾ Osaka ¾ Jeanty
AC Method ¾ Merz
¾ Hadlock ¾ Osaka
¾ Hansmann Ulna Method
¾ Tokyo ¾ Jeanty
¾ Merz ¾ Merz
¾ Campbell ¾ Mediscan
TAD Method Tibia Method
¾ Hansmann ¾ Jeanty
OFD Method ¾ Merz
¾ Hansmann AUA Result by
HC Method ¾ Average
¾ Hadlock ¾ Last
¾ Jeanty Edit or Create user define table
¾ Chitty(M) ¾ Replace
¾ Chitty(D) ¾ Save
¾ Merz ¾ Cancel
¾ Campbell →Annotation Edit
GS Method Insert
¾ Nyberg Delete
¾ Hansmann Edit
¾ Hellman Save
¾ Tokyo →Define quick key
¾ China Allow all OB measurement in Quick
Fibula Method Key in user defined
¾ Merz →Load Default
Radius Method Load
¾ Merz Create
¾ Mediscan Retrieve
Humerus Method ¾ Copy user setting to USB
901-00122
Page 8 of 17
Specifications for S20 High-Performance Color System
¾ Copy user preset to USB →End
¾ Load USB user setting to system →Frame By Frame
¾ Load USB user preset to system →Baseline
M-Mode
Post-Processing →Chroma
z RAW data digital processing →Video Invert
z Read Zoom up to 10x →Display Format
B Mode →Start
→GSC →End
→Chroma →Frame By Frame
→LT→RT
→Play/Stop Scanning Parameters
→Loop Speed B-Mode
→Start z Gain:1-255 adjustable
→End z Depth: 32.9 cm Max (probe dependent)
→Frame By Frame z zoom: Max.>= 10,Show zoom X value
Color Flow Mode z TGC(Time Gain Control) 8 slide controls
→C Map z Left and Right Inversion
→B Reject z Up and Down Inversion
→Finv: Flow Invert z 2B mode
→Loop Speed z 4B mode
→Start z Compound Image: ON/OFF
→End z Focus: Up to 12, focus span adjustable
→Play/Stop z Frequency : 5 steps
→Frame By Frame z Chroma: Max.13 selectable
PW/CW -Mode z Adapt . IM Fusion: 15 kinds
→Chroma z u-Scan: adjustable
→Video Invert z Line Density: 3 selections (high/med/low)
→Display Format z Persist (Frame correlation): 0-95 (probe
→Start dependent)
901-00122
Page 9 of 17
Specifications for S20 High-Performance Color System
z Biopsy Guide: on/off z Filter: Up to 750 Hz (exam dependent)
Biopsy Offset adjustable z Pulse Repetition Frequency: 0.5-12KHZ
Biopsy Angle adjustable z Line Density: 2 kinds (low and high)
z Dynamic range-compression selections: z Color Map: 11 kinds (probe dependent)
20-280 (probe dependent) z Baseline: ±15 steps
z GSC(gray scale curve) 7 steps selectable z Persist: 0-80(probe dependent)
z SEC.WIDTH: B Image width adjustable z B Reject: 0-255
z SEC.POS: B image lateral position z Steer Angle: 5 kinds (linear probe )
adjustable Max. ±20 degrees,
z Power%: 1 to 100 changeable 0, ±16, ±20 changeable
z Tissue acqustic: Adjustable according to z Imaging Area and Position (adjustable)
tissue type (1400-1700,10steps each)
z Trapezoid Image: ON/OFF(liner array M-Mode
probe) z Steer M: 3 lines, Display Frame Rate,
z B Steer Mode Allow Steer M to store in user define
preset
Color Flow Mode/TDI Mode z Video Invert: ON/OFF
z Gain: 0-255 adjustable z Up and Down Inversion
z Frame Rate: ≥50 frames/sec z M Process: Switch average or peak
z Color Area Size and Position: adjustable detection processing for the M vector
z Single auto focus while color ROI display.
movement z sweep speed: 2、4、6、8sec/plane
z Left / right: ON/OFF z Chroma: 5 kinds selectable
z Up / Down: ON/OFF z Display format: H1/2、H1/4、V1/3、V1/2、
z Zoom function V2/3、O1/4
z 2B mode z Power% : 30 to 100 changeable
z 4B mode
z B and B(Flow) Simultaneous Real-time Spectral Doppler
Display z Doppler methods
z Finv: Flow Invert (ON/OFF) PW (pulsed wave) Doppler
z Frequency Range: 5 steps
901-00122
Page 10 of 17
Specifications for S20 High-Performance Color System
CW Doppler 3D/4D Mode
z 2D Refresh: on/off z 3 arbitrary sections simultaneously
z Sample Volume Size for PW Doppler: z Display mode
1 -20 mm, changeable in 1 mm step, Dual Display
display Doppler Sample Volume Size. Quad Display
z Video Invert: on/off Full Display 2D
z 2B Mode Full Display 3D
z Finv: Spectrum Inversion Full Display 4D
z Angle: 0-80 degrees z Clip Plane: on/off
z Angle Correction: on /off z Undo Cut
z Auto Trace function in Real time z Rotate X
z BaseLine Shift: Available up to 17 steps z Rotate Y
z Frequency : 5 steps z Rotate Z
z WF: 25-750 z Move L-R
z High Pulse Repetition Frequency z Move U-D
PW: 1-20KHz (exam dependent) z Zoom
CW: 1-48KHz z Trace Cut: on/off
z Max velocity range: z Render Mode: Vol、MaxIP、X-ray
0.0004-40.9 m/s(pw) z Auto Rotate (45、90、180、270、360
0.0013-49.1 m/s(cw) degrees adjustable )
z Sweep Speed: 2、4、6、8sec/plane z Opacity Offset: 0-255 adjustable
z Power% : 30 to 100 changeable z Opacity Slope: 0-255 adjustable
z Chroma: Max.5 Kinds adjustable z Scan Method: Lin、Sec
z Dynamic Rage: 10 steps selectable z Z Scale: adjustable
z Display format: H1/2、H1/4、V1/3、V1/2、 z Z Angle: 10-170°adjustable
V2/3、O1/4 z Color Map:4 kinds
z Steer Angle: 5 kinds (linear probe ) z Multi-slice:Ref A、Ref B、Ref B
Max. ±20 degrees, z Slice Spacing:0.5-2.0 adjustable
0, ±16, ±20 changeable z Clip Plane:
z Cine Review: on/off
901-00122
Page 11 of 17
Specifications for S20 High-Performance Color System
z Rescan: on/off statement issued by SonoScape.)
z Stabilization z Storage: Directly transmits image with
z Sweep Angle:20-75 degrees patient information to a DICOM file server
z Image Quality: high、med、low
z Volume Review Physiological Signal Display
z 4D Gain: adjustable z ECG, Pulse wave
z Frame Rate: 5 frames/sec or more z ECG Lead-three lead system
z Print z ECG Gain: adjustable
z full scan of the Region of interest z ECG Position: adjustable
z Save images z ECG Invert:on/off
z R-Trigger:on/off
Integrated Data Management Trigger Delay: adjustable
System Frame Count: adjustable
z Hard Disk memory capacity: 320 G
z Storage media:USB Drive User Interface
Operator Keyboard
Storage of Images and Cine z Shortcuts Keyboard
z Cine loop: 10000 frames or more z Integrated Recording Keys for Remote
z Cine loop time:60 seconds or more Control of Peripheral Devices and DICOM
z Real time single/dual static and dynamic Devices
Image storage z 8 TGC Pods
z Archived image can be viewed on PC z Integrated function key
z Cropboard function: in Freeze Mode Character and icon
z Cine play back mode for Dop. z Character Input Area: ID, Name, DOB,Sex,
z Doppler Cine Sound Play Back Function Weight, Height, LMP etc
z Body Mark:52 kinds
DICOM Network Communication
z Conformity to DICOM Standard: Service Electrical Power
class user of storage, (for details, please z Voltage:100/220 Volts AC
refer to the DICOM conformance z Current: 3.15 Amps
901-00122
Page 12 of 17
Specifications for S20 High-Performance Color System
z Frequency:50/60Hz →C362 (2-6 MHZ)
→C542 (3.7-11 MHZ)
Environmental Requirements z Micro-curved Probe(Transvaginal)
In operation →6V1 (3.9-15 MHZ)
z Temperature:+10 to +40 degrees C →6V3 (3.9-15 MHZ)
z Relative Humidity: 30% to 75% z Micro-curved Probe(Cardiology)
(non condensing) →C311 (2-6 MHZ)
z Atmospheric pressure: 700 to 1060hPa →C611 (4-13 MHZ)
In Storage/Transportation z 4D Probe
z Temperature: -20 to +55 degrees C →VC6-2(2-7 MHZ)
z Relative humidity: 20%- 90% z Linear,Surgical(Surgery)
(non condensing) →10I2 (4.5-15 MHZ)
z Atmospheric Pressure: 700 to 1060hPa
Measurements/Calculations
Probe Connectors z General Measurements/Calculations
z Active Connectors: 3 connectors On B-Mode
→Distance(real time、freeze)
Optional Probe →Area and circumference (Trace, Ellipse)
z Phased Array Probe(Cardiology) (real time、freeze)
→2P1 (1.9-6 MHZ) →Volume (L×W×H,Area×L)
→5P1 (4.2-11 MHZ) →Angle
z Linear Probe(Vascular, Small Part) On M-Mode
→L741 (5-16 MHZ) →Velocity
→L742 (7-15 MHZ) →Distance
→L743 (7-16 MHZ) →Time
→L752 (4.5-15 MHZ) →Heart rate
→10L1 (4.5-15 MHZ) →Slope
→L541 (3.7-9 MHZ) On Spectral Doppler
z Curved Probe(Abdomen, OB/GYN) →Time Interval
→C344 (2-7 MHZ) →Velocity
901-00122
Page 13 of 17
Specifications for S20 High-Performance Color System
→Velocity Ratio →AC (Abdominal Circumference)
→Velocity Time Integral →FL (Femur Length)
→Heart Rate →CER (Cerebellum)
→Velocity →OFD (Occipitofrontal Diameter)
→Acceleration →Fibula (Fibula Length)
→Resistance Index →Foot (Foot Length)
→Pulsatility Index →AA (Abdominal Area)
→Pressure half time →APAD (Anteroposterior Abdominal
→PV(peak Velocity) Diameter)
→Mean Flow Velocity →HA (Head Area)
→End diastolic Velocity →Humerus (Humerus Length)
→PG((Pressure gradient) →Kidney (Kidney Length)
→Auto Trace →APTD (Anteroposterior Trunk Diameter)
→Manual trace →OOD (Outer Orbital Diameter)
On Color Mode →Radius (Radius Length)
→Color Flow Velocity →TAD (Transverse Abdominal Diameter)
→Doppler Area →TC (Thoracic Circumference)
→proximal Isovelocity surface area →THD (Thoracic Diameter)
On 4D-Mode →Tibia (Tibia Length)
→Distance →TTD (Transverse Trunk Diameter)
→Area and circumference →Ulna (Ulna Length)
→Volume →Umb VD (Umbilical Vein Diameter)
→NT (Nuchal Translucency)
z Obstetrical/ Gynecological →LV (Lateral Ventricle)
Measurements & Calculations →UT L (Uterus Length)
B Mode →UT H (Uterus Height)
→GS (Gestational Sac diameter) →UT W (Uterus Width)
→CRL (Crown Rump Length) →Cx (Cervix)
→BPD (Biparietal Diameter) →En-T (Endometriosis)
→HC (Head Circumference) →Rt OV L (Right Ovary Length)
901-00122
Page 14 of 17
Specifications for S20 High-Performance Color System
→Rt OV H (Right Ovary Height) Length at end Systole
→Rt OV W (Right Ovary Width) Biplane Ellipse Method
→Lt OV L (Left Ovary Length) ¾ LVALd: Left Ventricular Long-axis
→Lt OV H (Left Ovary Height) Area at end Diastole
→Lt OV W (Left Ovary Width) ¾ LVALs: Left Ventricular Long-axis
→AFI (Amniotic Fluid Index) Area at end Systole
→Dominant Follicle ¾ LVAMd: Left ventricular short-axis
→EFA(Estimated Fetal Age) area at end diastole
→EDD(Estimated Date of Delivery) ¾ LVIDd: Left ventricular short-axis
→EFW ( Estimated Fetal Weight) diameter at end diastole
→AUA(Average Ultrasound Age) ¾ LVAMs: Left ventricular short-axis
→Fetal HR(Fetal Heart Rate) area at end systole
PW Mode ¾ LVIDs: Left ventricular short-axis
→Umb A (Umbilical Artery) diameter at end systole
→MCA (Middle Cerebral Artery) Bullet
→Rt Uterin A (Right Uterine Artery) ¾ LVAMd: Left ventricular short-axis
→Lt Uterin A (Left Uterine Artery) area at end diastole
→Fetal AO (Fetal Aorta) ¾ LVAMs: Left ventricular short-axis
area at end systole
z Cardiac measurements ¾ LVLd: Left ventricular long-axis
B-Mode length at end diastole
→Left Ventricular Fuction Measurement ¾ LVLs: Left ventricular long-axis
Single Plane Ellipse Method length at end systole
¾ LVALd: Left Ventricular Long-axis Simpson Method
Area at end Diastole ¾ LVAMd: Left ventricular short-axis
¾ LVLd: Left Ventricular Long-axis area at end diastole
Length at end Diastole ¾ LVAMs: Left ventricular short-axis
¾ LVALs: Left Ventricular Long-axis area at end systole
Area at end Systole ¾ LVAPd: Left ventricular short-axis
¾ LVLs: Left Ventricular Long-axis area at the level of the
901-00122
Page 15 of 17
Specifications for S20 High-Performance Color System
papillary muscle at end Gibson
diastole ¾ LVLDd: Left ventricular short-axis
¾ LVAPs: Left ventricular short-axis diameter at end diastole
area at the level of the ¾ LVIDs: Left ventricular short-axis
papillary muscle at end diameter at end systole
systole Biplane Disk
¾ LVLd: Left ventricularlong-axis ¾ Diastole 2CH
length at end diastole ¾ Diastole 4CH
¾ LVLs: Left ventricular long-axis ¾ Systole 2CH
length at end systole ¾ Systole 2CH
Cube →Mitral Valve Diam
¾ IVSTd: Interventricular septal →Lv Outflow Diam
thickness at end diastole →Pul.Valve Diam
¾ LVIDd: Left ventricular short-axis M-Mode
diameter at end diastole →Left Ventricular Fuction Measurement
¾ LVPWd: Left ventricular posterior Cube
wall thickness at end ¾ LVIDd: Left ventricular short-axis
diastole diameter at end diastole
¾ IVLTs: Interventricular septal ¾ LVIDs: Left ventricular short-axis
thickness at end systole diameter at end systole
¾ LVIDs: Left ventricular short-axis ¾ LVPWd: Left ventricular posterior
diameter at end systole wall thickness at end
¾ LVPWs: Left ventricular posterior diastole
wall thickness at end ¾ LVPWs: Left ventricular posterior
systole wall thickness at end
Teichholz systole
¾ LVLDd: Left ventricular short-axis Gibson
diameter at end diastole ¾ LVLDd: Left ventricular short-axis
¾ LVIDs: Left ventricular short-axis diameter at end diastole
diameter at end systole ¾ LVIDs: Left ventricular short-axis
901-00122
Page 16 of 17
Specifications for S20 High-Performance Color System
diameter at end systole →DR PED (Dorsalis Pedis)
Teichholz →%A REDUC (Area reduction percent)
¾ LVLDd: Left ventricular short-axis →%D REDUC (Diameter reduction
diameter at end diastole percent)
¾ LVIDs: Left ventricular short-axis →PI (Pulsatility Index)
diameter at end systole →RI (Resistive Index)
→Mitral Valve Measurement →S/D (Systolic/Diastolic Ratio)
→Aortic Valve Measurement →PG((Pressure gradient)
PW-Mode →PV(peak Velocity)
→Mitral Valve Measurement →IMT
→Aortic Valve Measurement
→Tricuspid Valve Measurement z Urological Measurements Calculations
→Pulmonary Valve Measurement →Left Kidney
→TEI Index Doppler Measurement →Right Kidney
→Left-Renal Cortex
z Vascular Measurements Calculations →Right-Renal Cortex
→ICA (Internal Carotid Artery) →Left-Adrenal Gland
→ECA (External Carotid Artery) →Right- Adrenal Gland
→CCA (Common Carotid Artery) →Bladder Volume
→INT IL (Internal iliac) →Residual Urine
→EXT IL (External iliac) Urine Area
→ILIAC (Common iliac) Urine Height
→CFA (Common Femoral Artery) →Whole Prostate Volume
→PROFUN (Profunda) →Trans Zone Volume
→LT CIR (Lateral Circumflex) →Left-Seminal Vesicles
→SFA(Superficial Femoral Artery) →Right- Seminal Vesicles
→POP (Popliteal Artery) →Left-Testicle
→PTA (Posterior Tibial Artery) →Right- Testicle
→PERON (Personal Artery)
→ATA (Anterior Tibial Artery) z Small Part Measurements
901-00122
Page 17 of 17
Specifications for S20 High-Performance Color System
→L-Thyroid
→R-Thyroid
→Thyroid Isthmus
→L-Superior Parathyroid
→L-Inferior Parathyroid
→R-Superior Parathyroid
→R-Inferior Parathyroid
z Orthopaedic Measurements
→HIP(Hip Joint)
z Report functions
→Obstetrical /Gynecological report
(revisability)
Obstetrical Curve
Fetal Anatomy
Biophysical Profile
Fetal Compare (quadruplets)
Picture
Comment
→Cardiac function report(revisability)
→Vascular report
→Urological report
→Small Part report
→IMT report
901-00122
Page 18 of 17
Specifications for S20 High-Performance Color System
z The specifications are subject to change without notice.
z Not all the products are available in all countries.
z Please contact your local Sonoscape representative.
Address: 4/F, Yizhe Building, Yuquan Road, Shenzhen, Guangdong, China
Post code: 518051
Tel: 86-755-26959990,86-755-26722890,86-755-26722860
Fax: 86-755-26722850
Website: http://www.sonoscape.net
E-mail: [email protected]
901-00122
Page 19 of 17