0% found this document useful (0 votes)
341 views1 page

Walling Plan

The document contains plans and details for a partition and roof ventilation system. The partition plan shows 25mm wood slats and frames spaced at 50mm intervals and supported by vertical and horizontal 24 gauge metal studs at 400mm spacing. The roof ventilation plan shows a fiber cement board roof with metal furring strips at 600mm intervals, supported by a firewall. It also details 150mm x 200mm PVC gutters with internal brackets and 100mm diameter PVC downspouts.

Uploaded by

DJ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
341 views1 page

Walling Plan

The document contains plans and details for a partition and roof ventilation system. The partition plan shows 25mm wood slats and frames spaced at 50mm intervals and supported by vertical and horizontal 24 gauge metal studs at 400mm spacing. The roof ventilation plan shows a fiber cement board roof with metal furring strips at 600mm intervals, supported by a firewall. It also details 150mm x 200mm PVC gutters with internal brackets and 100mm diameter PVC downspouts.

Uploaded by

DJ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

0.

40

1/4" HARDIFLEX
25mm. x 25mm. WOOD SLATS
SPACED @ 50mm. O.C. GA. 24 2" x 3" METAL STUDS
( VERTICAL ) SPACED @
0.40mm. ON CENTER

25mm. x 50mm. SOLID


WOOD FRAMES
GA. 24 2" x 3" METAL STUDS
( HORIZONTAL ) SPACED @

0.30
0.40mm. ON CENTER

PROVIDE INSECT SCREEN

4 PLAN OF PARTITION
A-5 SCALE : 1 : 10 MTS.

GA. 24 2" x 3" METAL STUDS


( VERTICAL ) SPACED @
0.40mm. ON CENTER

3 ROOF VENTILATION PLAN


A-5 SCALE : 1 : 50 MTS.

A B A B
4.00 4.00
1.925 2.075 1.925 2.075
0.70 1.375 0.70 1.375
150mm. x 200mm.
0.30 0.40 0.30 0.40 PVC GUTTER ON
6mm. THK. FIBER CEMENT BOARD ON INTERNAL BRACKETS
100mm. DIA. PVC
19mm. x 50mm. x 0.40mm. THK. METAL DOWNSPOUT
FURRING @ 600mm. O.C.
FIREWALL FIREWALL
2.00

2.00
0.40 0.30

0.40 0.30
0.70

0.70
0.50mm. THK. PRE-PAINTED
EAVES LINE G.I. FLASHING

3 3 BUILDING LINE
5 ISOMETRIC OF PARTITION
A-5 SCALE : 1 : 10 MTS.

EXPOSED 150mm. x 65mm. x 20mm. x 2.0mm.


LIP CHANNEL PURLINS SPACED @ 700mm.
O.C. WITH 12mm. DIA. SAGROD @ MIDSPAN GA. 24 2" x 3" METAL STUDS
( VERTICAL ) SPACED @
0.40mm. ON CENTER
3.25

3.25
0.50mm. THK. PRE-PAINTED
G.I. RIDGE ROLL

1/4" HARDIFLEX
FIREWALL

FIREWALL
FIREWALL

FIREWALL
6.50

6.50

2 2

0.50mm. THK. PRE-PAINTED


RIB-TYPE G.I. SHEET ROOFING

0.50mm. THK. PRE-PAINTED


RIB-TYPE G.I. SHEET ROOFING GA. 24 2" x 3" METAL STUDS
( HORIZONTAL ) SPACED @
3.25

3.25

0.40mm. ON CENTER

150mm. X 200mm.
PVC GUTTER

BUILDING LINE
1 1
0.30 0.40

0.30 0.40
0.70

0.70

EAVES LINE

ROOF VENTILATION
( SEE DETAIL )

1 REFLECTED CEILING PLAN 2 ROOF PLAN


A-5 SCALE : 1 : 50 MTS. A-5 SCALE : 1 : 50 MTS. 6 ELEVATION OF PARTITION
A-5 SCALE : 1 : 10 MTS.

PROJECT TITLE : Republic of the Philippines ARCHITECT / ENGINEER DESIGNED: HTTRD CHECKED: RGRAMOS SHEET NO.
MUNICIPALITY OF TIGAON Office of the President
Province of Camarines Sur DRAWN: PLIBARDALOZA DATE:
NATIONAL HOUSING AUTHORITY
CHECKED BY RECOMMENDING APPROVAL SHEET CONTENT

REVIEWED BY A-5
TIGAON RESETTLEMENT PROJECT P1 REFLECTED CEILING PLANS,
ROOF PLAN, ROOF
VENTILATION PLAN, DET. OF PARTITION
DESIGNATION
APPROVED BY REVISIONS DATE:

LOCATION : Engr. CRISTINA A. CABANGON Engr. ALBERT A. PERFECTO MARCELINO P. ESCALADA JR. 5 12
REG No.: DATE:
BRGY. SALVACION, TIGAON, CAMARINES SUR DISTRICT MNGR DISTRICT II - REGION V REGIONAL MANAGER REGION V GENERAL MANAGER, NHA
MUNICIPAL MAYOR PTR No.: PLACE: