C18 Industrial Engine GJE00001-UP(SEBP4247 - 52) - Systems & Components Page 1 of 1
Shutdown SIS
Previous Screen
Product: INDUSTRIAL ENGINE
Model: C18 INDUSTRIAL ENGINE GJE
Configuration: C18 Industrial Engine GJE00001-UP
Testing and Adjusting
C15 and C18 Industrial Engines
Media Number -SENR9843-13 Publication Date -01/10/2014 Date Updated -22/08/2017
i04351755
Water Temperature Regulator - Test
SMCS - 1355-081-ON; 1355-081
Personal injury can result from escaping fluid under pressure.
If a pressure indication is shown on the indicator, push the release valve
in order to relieve pressure before removing any hose from the radiator.
1. Remove the water temperature regulator from the engine.
2. Heat water in a pan until the temperature is 98 °C (208 °F).
3. Hang the water temperature regulator in the pan of water. The water temperature regulator
must be below the surface of the water and away from the sides and the bottom of the pan.
4. Keep the coolant at the correct temperature for 10 minutes.
5. After10 minutes, remove the water temperature regulator. Ensure that the water temperature
regulator is open. Refer to Specifications, "Water Temperature Regulator" for the correct
opening distance of the water temperature regulator at the full open temperature.
Replace the water temperature regulator if the water temperature regulator is not open at the
specified temperature.
Copyright 1993 - 2019 Caterpillar Inc. Fri Sep 20 20:46:44 UTC+0200 2019
All Rights Reserved.
Private Network For SIS Licensees.