Fibr An S.A. I Nsula Tion M A T Erials I Ndustr y

The document discusses FIBRANgeo stonewool insulation materials. FIBRANgeo is a stonewool insulation material produced from molten rock that is spun into fibers. It provides thermal and sound insulation as well as fire protection. FIBRANgeo has high thermal resistance, is non-combustible, water repellent, resistant to mechanical loads, and breathable.

Uploaded by

Alin Stancu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views28 pages

Fibr An S.A. I Nsula Tion M A T Erials I Ndustr y

The document discusses FIBRANgeo stonewool insulation materials. FIBRANgeo is a stonewool insulation material produced from molten rock that is spun into fibers. It provides thermal and sound insulation as well as fire protection. FIBRANgeo has high thermal resistance, is non-combustible, water repellent, resistant to mechanical loads, and breathable.

Uploaded by

Alin Stancu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

FIBR AN S.A.

I nsula tion M a t erials I


ndustr y
0 design by: FIBRAN S.A. - July 2017

6th k lm. T hessalonik i - Or eok astr


o
P.O. Bo x 40 306 - A.C. 564 10
T he ssalonik i, Gr eece
fibran@fibran. com
w w w.fibran.g r facebook .com/fibranI nt er national
20
product catalogue

FIBRAN
gΤhermal
e o insulation, sound insulation
Stonewool

and fire protection products for building applications


FIBRANgeo stonewool building
insulation. Natural and hard like a stone!
FIBRANgeo stonewool products are industrially produced from molten rock spun into fibres. They
are classified as mineral wool products for use in building insulation, according to the European
Standard EN 13162 (Mineral Wool insulation products for buildings).
All FIBRANgeo stonewool insulation products meet the QUALITY and SAFETY requirements of
the European Standards.
Stonewool insulation is a natural inorganic fibrous material, widely recognised for its thermal and
sound insulating properties, as well as its excellent performance towards fire protection.

FIBRANgeo stonewool insulation is a natural inorganic


for its thermal and sound insulating properties, as wel
FIBRANgeo is produced from mineral rock, initially fused in an electric furnace at 1520°C and then spun into fibres. The use of
electric furnace technology for its production allows for the precise control of the melt’s temperature, in comparison to the
blast furnace method employed by more than 90% of stonewool manufacturers. The maintenance of steady temperatures
during the melting process ensures the fibres’ dimensional stability and provides excellent technical characteristics to the final
products. Moreover, non-use of fossil fuels (e.g. coke) as a main production fuel minimises polluting gas emissions in the
environment.
Once past the spinning phase, the loose stonewool fibres, with the addition of adhesive resin, oil and special silicon compounds
that provide hydrophobicity, become cohesive, elastic and water-repellent.
FIBRANgeo stonewool is formed in boards, rolls and loose fill in a variety of dimensions, and is, finally, packed.
Boards and rolls may also be manufactured with facings.

02
fibrous material, widely recognised
l as its excellent performance towards fire protection.

Thermal insulation Fire protection Humidity Sound Energy saving Mechanical


resistant absorbtion resistance

03
The power of nature

Advantages of FIBRANgeo
FIBRANgeo stonewool is the material which offers insulation against undesired thermal losses & gains, fire
hazards and noise pollution! Therefore, with the use of a single insulation material, the building is shielded
against all these problems/issues/factors, while at the same time achieving excellent passive ventilation and
remaining environmentally friendly.

Thermal insulation Fire Protection Sound insulation


Excellent thermal insulation, with a very Non-combustible materials (Class A1 High sound absorption coefficient
low thermal conductivity coefficient in accordance to EN 13501-1) which and optimum air flow resistivity. These
and maximum thermal resistance maintain their insulating properties in properties provide increased sound even
at high temperatures. The fibres’ high temperatures, contributing to the reduction and improved acoustic softening
temperature is over 1.000 inhibition of the spread of fire, saving performance of spaces. Facings maximise
°C and their binder starts to evaporate lives and protecting built structures and sound reduction required in certain when its
temperature exceeds 200 °C, the properties. frequencies.
materials’insulating properties remaining Therefore, they constitute key parts of fire High compressive strength and very unchanged.
Therefore, FIBRANgeo resistant walls, floors, roofs, prefabricated low dynamic stiffness, i.e. very rigid, yet products are also
suitable for applications panels, doors or other passive fire efficiently resilient. These properties where high
temperatures occur. protective systems. reduce impact noise transmission, such
as in floating floor applications.

04
FIBRANgeo stonewool is 100% compatible with other
insulating materials, such as FIBRANxps or
FIBRANeps. All these materials can be used at the
same project, to satisfy the technical requirements of
different building applications such as basement, walls,
pitched roof and terrace.

Passive Ventilation Water Repellence - non-hygroscopic Resistant to mechanical loads


Open hive structure materials with water FIBRAN geo st one wool produc ts,
The fibres’ hydrophobicity renders
vapour diffusion resistance similar to the depending on the fibres’ knit and
FIBRANgeo products water repellent
resistance of air (μ=1). These properties orientation, have high mechanical
and non-hygroscopic. Stonewool fibres
enhance the construction elements’ strength even in relatively low densities.
are not affected by moisture or water.
breathability, by allowing the flow of
If stonewool gets wet, it dries fast via
very small quantities of air and vapour
passive ventilation and fully regains its
through the building envelope, due
initial properties. Further, it does not
to air pressure differences occurring
accumulate moisture, when in contact
between indoors and outdoors (Passive
with other wet parts of the construction.
Ventilation).
Ventilation replenishes oxygen, regulates
the spaces’relative humidity and removes
unpleasant smells, smoke, dust, airborne Natural, inorganic, odourless, chemically inert (practically neutral Ph)
bacteria and carbon dioxide.
It does not chemically erode construction elements it remains in contact with, nor is it
FIBRANgeo products assure the maximum
eroded by them, even in conditions of increased humidity.
passive ventilation of buildings, satisfying
the requirements of Bioclimatic Design. Lightweight, easy to handle, cut and install

Resistant to vibrations
Does not allow the development of micro-organisms, insects or rodents

Recyclable

Friendly to the environment and to the end user

05
Applications of FIBRANgeo Facings of FIBRANgeo
FIBRANgeo products are suitable for use in all building types. FIBRANgeo products are available with
They are suitable for the insulation of all building elements, such as the following standard facings to meet
walls, floors, ceilings, roofs, terraces, building equipment, particular application requirements:
mechanical installations, sound insulating and passive fire
prevention systems. AX: Aluminium kraft paper foil reinforced with fibreglass mesh
AL: Aluminum foil reinforced with fibreglass mesh
ROOFS
FACAD YM: Black non-woven fibreglass fleece
E DRY YA: White non-woven fibreglass fleece
FLOO XA: Kraft paper
RS BIT: Bitumen coating
ROLLS PB: Plastic
For selection of the suitable product type, please refer to the Bag
Product Selector by Application on page 07.

FIBRAN Solutions
FIBRANtools
FIBRAN offers solutions for each application: FIBRAN offers a wide range of quality tools, for DRY construction
FIBRANroof, FIBRANwall, FIBRANfloor, FIBRANdry & insulation applications.

Refer to the specific chapter for more information.

Packaging of FIBRANgeo
FIBRANgeo products are supplied packed. The appropriate
number of boards and individual rolls are shrink-wrapped in
PE film, in packages and rolls. The appropriate number of
packages is shrink-wrapped weather tightly, with an extra outer
PE film, in pallets. For details about packages and
pallets for particular FIBRANgeo product types, please refer to
pages 08 to 20 (www.fibran.gr).

A: 1200 X 1200 or 1000 X 2400 mm


B: 1200 X 1000 X 1200 mm

Types of FIBRANgeo
The standard unfaced FIBRANgeo product range is:

Boards with knit fibres and 4-sides L-cut: BP 50-L, BP HD-L, BP 70-L
Boards with knit fibres: BP series ΒP 80, BP 70, BP HD, BP 50, BP 40, BP 30, BP-ETICS
Boards: B series B-001, B-570
Rolls: R series R-050, R-040,
Loose fill: XS-LOOSE

06
Certifications of FIBRANgeo

0751

All FIBRAN geo st one w ool insu la tio n pr oduc ts meet the QUALIT Y and SAFE T Y r equir ements of the E ur opean Stand ar ds .

CE certification

All FIBRANgeo stonewool insulation products conform to the European Regulation (CPR) 305/2011, which replaced the European Directive 99/91/ EEC. In
compliance with CPR, all types of FIBRANgeo stonewool products hold the CE marking and are in conformity with the European Norm EN13162, which
refers to mineral wool insulation products used in building applications. Also, FIBRAN has created the Declaration of Performance for every product type
which can be downloaded from: http://www.fibran.gr/dop. In accordance with the abovementioned European Νorm, every insulation product acquires a
designation code, which declares its technical characteristics.

For example:
MW - EN 13162 – Ti - CS(10)i – TRi - PL(5)i – CPi – WS - WL(P) – MUi – SDi - AFri – AWi
• MW – Factory made mineral wool insulation material, industrially manufactured from molten rock, slag or glass.
• EN 13162 – The European Standard number.
• Ti – Thickness Tolerances. Classes for thickness tolerances from the nominal thickness (e.g. Class T4 : - 3mm + 5mm).
• CS(10)i – Minimum compressive stress at 10% thickness deformation (kPa).
• TRi – Minimum tensile strength perpendicular to faces (kPa).
• PL (5)i – Point Load (N). Minimum compressive load (applied on a small area of 50 cm²) at 5 mm thickness deformation.
• CPi – Compressibility (mm). The max. difference between the thickness dL, under a light load of 0.25 kPa, and the thickness dB, under a load of 2 kPa (+ - 48 kPa).
• WS – Short Term Water Absorption (kg/m²) with partial immersion in water for 24 hours <1 kg/m².
• WL(P) – Long Term Water Absorption (kg/m²) with partial immersion in water for 28 days <3 kg/m².
• MUi – Water Vapour Transmission. The maximum ratio (factor μ) of water vapour diffusion resistance of the material to the resistance of an equal
thickness of air.
• SDi – Dynamic Stiffness (MN/m³). The maximum ratio (factor s’) of dynamic compressive stress to dynamic change in thickness.
• AFri – Air flow resistivity (kPa s/m²). The minimum air flow resistance coefficient of 1m thickness material >5 kPa s/m².
• AWi -Weighted Sound Absorption Coefficient. The value of the sound absorption coefficient αw in the frequency of 500Hz, measured on the
standard weighted sound absorption curve.
The thermal conductivity λD and the thermal resistance RD, as well as the fire classification should also be declared.
• λD - Declared Thermal Conductivity (W/mK). The maximum expected nominal thermal conductivity during the material’s working life, at mean
temperature 10 °C (greater than the test results), in accordance with EN 13162.
Thermal conductivity λ (W/mK) is the heat amount transmitted through a layer of material, with 1 m² surface area and 1 m thickness, when a constant
temperature difference of 1 K is maintained between the layer’s faces.
• RD - Declared Thermal Resistance (m²K/W ). The minimum expected nominal thermal resistance during the material’s working life, at mean
temperature 10 °C (less than the test results), in accordance with EN 13162.
Thermal resistance R (m²K/W) is the ratio of the material’s thickness d to the material’s thermal conductivity λ.
• Fire Classification – Building materials are classified depending on their reaction to fire in Classes A1 (non-combustible), A2, B, C, D, E to F (no
performance determined), in accordance with EN 13501-1.

The quality of FIBRANgeo products is assured in accordance with EN 13162 and EN 13172 standards.
These standards establish the type and frequency of measurements executed both by recognized and independent institutions, as well as
by FIBRAN laboratories.
0751

EUCEB Certification

All FIBRANgeo stonewool insulation products also carry the certification mark EUCEB (European Certification Board for Mineral Wool Products). EUCEB is
an independent organisation whose procedures ensure compliance of mineral wool insulation products with the Directive’s 97/69/EC, Note Q, regarding their
fibres biosolubility and their non-classification as ‘carcinogenic’ materials.
Moreover, according to EC Regulation 790/2009 (August 10, 2009) stonewool insulation products are no longer classified as products causing skin irritation
(R38).

ISO 9001:2008 Certification

The quality management system of FIBRAN S.A. complies with EN ISO 9001:2008 for the design and manufacture of Mineral Wool (MW), as certified by
the independent body TÜV NORD CERT, with initial Certificate Registration No. 04 100 960680.

FIBRAN S.A. shall not be held liable for any damage caused by improper use of the products, transportation, storage and handling.

07
Pannelli in lana di roccia per l’edilizia
according to ΕΝ 13162 FIBRANgeo

BP - ΕTICS PLUS
NE NE NE NE
W W W W

EN Standard
BP - ΕTICS
BP HD-L
BP 70-L

BP 50-L

R - 050

R - 040
B - 002

B - 571

Β - 051

B - 001

B - 570

B - 050

B - 040

B - 030
BP HD
BP 80

BP 70

BP 50

BP 40

BP 30
Type

Unit
Symbol
Product

Technical data

30- 30- 30- 30- 30- 30- 30- 30- 30- 30- 40- 20- 20- 20- 20- 30- 40- 40- 40-
Thickness dN mm 30-60 30-60 EN
200 200 200 200 200 200 200 200 200 200 200 150 200 200 200 200 200 200 200
823

Thickness Tolerance T Clas T7 T7 T7 T7 T7 T7 T7 T7 T7 T5 T5 T7 T7 T6 T4 T4 T4 T4 Τ4 T4 T4 EN


i s 13162
L 9000- 10000-
Length mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1000 1000 1200 1200 1200 1200 1200 1200 1200 1200 EN 822
6000 6000

B 600 600 600 600 600 600 600 600 600


Width mm
2000 2000 2000 2000 2000 2000 2000 2000 2000
600 600 600 600 600 600 600 600 600 600 1000 1000 EN
822
Thermal EN 13162
0.037 0.037
conductivity λD W/mK 0.039 0.039 0.039 0.038 0.038 0.036 0.036 -0.039 -0.039 0.035 0.035 0.035 0.035 0.035 0.033 0.033 0.034 0.034 0.034 0.035 0.035 EN
12667
o
declared at 10 C EN 12939
Fire classification - Clas A1 (non combustible) EN 13501-
s 1
Softening
- 0
C > 1000 0C DIN 4102-17
temperature

Specific heat capacity C kJ/kgK 1.03 ISO


10456
Compressive stress
at 10% thickness CS(10)i kPa 80 70 70 50 50 40 30 60 60 30 20 50 25 20 5/10 - - - - - - EN 826
deformation

Point load for 5mm PL(5)


thickness deformation
N 800 700 700 600 600 550 400 600 600 - 550 350 200 - - - - - - - EN
i 12430
Compressibility
EN 13162
(cp=dL-dB) CPi mm - CP2 CP2 CP2 CP2 CP2 CP2 CP2 CP2 - CP2 CP2 CP2 - - - - - -
-
Design compressive - EN 12431
load
kN/m 2
25 20 20 15 15 12 10 20 20 - 15 8 7 - - - - - - - EN1316
2
Tensile strength
perpedicular to faces TRi kPa 20 20 20 15 15 15 10 20 20 10 7,5 - - - - - - - - - - EN 1607

Tensile strength
parallel to faces σt kPa - - - - - - - - - - - - - - - 14 12 10 5 5 EN
1608

Short term water WS


absorption (24 hours) kg/m2 <1 EN 1609

Long term water WL(P kg/m2


absorption (28 days)
<3 EN
) 12087

Water vapour diffusion ΜUi


resistance factor (μ) - 1 EN 12086

Air flow resistivity AFr kPa s/m2 60 60 60 60 60 60 60 60 60 60 60 60 60 60 50 30 15 10 30 15 EN


(r) i 29053

Weighted sound dN mm - 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
absorption coefficient EN ISO 354
(αw) EN ISO
AWi - - 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 1 1 1 1 1 1 1
11654

dN mm - 50 50 40 40 50 50 50 50 - 50 80 50 80 - - - - - -
Dynamic stiffness EN 29052-
(s’) SD MN/m3 - 35 35 32 32 27 20 30 30 - 23 9 10 5 - - - - - - 1
i

08
NEW NEW NEW NEW

BP 70 BP 70-L BP 50 BP 50-LBP 80
Product Type
PRODUCT SELECTOR FIBRANgeo

Application Area

FLAT
ROOFS
External insulation of concrete roof / steel deck with polymer
waterproofing membrane on insulation • • • • • • • • • • •
External insulation of concrete roof / steel deck with bitumen
waterproofing membrane on insulation •
Insulation on roof with floating concrete screed • • • • • • • • • • • •
Exposed internal insulation of steel deck •
PITCHED
ROOFS
Metal stonewool composite roof panel • • • • • • • • •
Twin-skin metal roof cladding (on site construction) with core
insulation • • • • • • •
Insulation between roof frame elements (rafters, beams, joists) • • • • • • • • • • •
Insulation on attic ceiling lining • • • • • • • • • • •
PILOTIS -
CEILINGS
Pilotis external thermal insulation composite system (ETICS) • •
DRY CONSTRUCTION

Pilotis external insulation with dry board cladding • • • • • • •


Insulation of dry construction ceiling (gypsum board, etc.) • • • • • • • • • • •
Insulation on non-perforated suspended ceiling lining • • • • • • • • • • •
Insulation on perforated ceiling lining • • • •
FLOOR
S
Floating concrete screed floor (e.g. marble, tile, industrial floor finish) • • • • • • • • •
Floating dry floor (e.g. solid wood/laminate flooring finish) • • • • • • • • •
Insulation between timber floor joists • • • • • • • •
WALL
S
Metal stonewool composite wall panel • • • • • •
Twin-skin metal wall cladding (on site construction) with core
insulation • • • • • •
Masonry cavity wall with core insulation • • • •
Insulation of ventilated facade (e.g. dry board cladding, marble,
ceramic tile, metal panels) • • • • •
Wall external thermal insulation composite system (ETICS) • •
DRY CONSTRUCTION

Partition wall with core insulation (gypsum board, etc.) • • • • • • •


Insulation of masonry wall with dry lining/cladding (gypsum
board, cement board, etc.) • • • • • • •
Insulation of wall with perforated dry lining (gypsum board, etc.) • • • •
SPECIAL APPLICATIONS For special applications special products can be produced

L = with NEW L-
CUT

Product Selector presents the most indicative building solutions. For any other solution please contact the technical support
department of FIBRAN S.A.
09
FIBRANgeo ROOF solution: single layer up to 300 mm
Flat Roofs
Thickness Packages Quantity Thermal Tensile Thermal Point Load Compressive Reaction
/pallet Resistance R Strength Conductivity λ Strength to Fire
[mm] /pallet (PL5)
FIBRANgeo 40 20
[m2]
86,40
(m2K/W)
1,05
(kPa) (W/mK) (N) (CS10) (kPa) (EN 13501-1)

BP-50 50
60
20
20
72,00
57, 60
1,35
1,60
70
80 24
20 51,84
43,20 12,15
,85
FIBRANgeo 10 0 16 34,56 2,70 15 0,037 600 50 A1
BP-50 120 20 28,80 3,20
Stonewool insulation boards for

140 18 25,92 3,75


L 16 0
18 0
14
14
20,16
20,16
4,30
4,85
200 12 17,28 5,40
Board dimension: 1200 x 1000 mm. Also available in dimensions 1200 x 600 mm and thicknesses greater than 160 mm.

FIBRANgeo Thickness
[mm] Packages
/pallet
Quantity
/pallet
2
Thermal R
Resistance
2
Tensile
Strength Thermal λ
Conductivity Point
(PL5)Load
(N)
Compressive
Strength Reaction
to Fire

40 20 86,40 1,00
50 20 72,00 1,25
FIBRANg 60
70
20
22
57, 60
47, 52
1,50
1,75
eo 80
10 0
20
24
43,20
34,56
2,05
2,55 20 0,039 700 70 A1
BP-70 L 12 0
140
20
36
28,80
25,92
3,05
3,55
16 0 28 20,16 4,10
18 0 28 20,16 4,60
200 24 17,28 5,10
Board dimension: 1200 x 1000 mm. Thickness up to 160mm available on request.

FIBRANgeo ROOF solution: boards with ready, factory-made


inclination
FIBRANgeo INCLINE BOARDS
The FIBRANgeo INCLINE system is an advanced, custom-made system
of modular elements that consists of factory-made boards with predefined
inclination.
NEW
The FIBRANgeo INCLINE stone wool boards are prepared
in the factory according to the drawings of the roof area, taking into
consideration water drainage and plan details. The boards arrive on site pre-cut
with the desired inclination, each with clear lettering
for easy installation.

FIBRANgeo BP-50 BIT


or FIBRANgeo BP-70 BIT
FIBRANgeo BP-
o70FIBRANgeo BP-80

10
FIBRANgeo ROOF solution: Metal deck with FIBRANgeo BP-
50,
Stonewool FIBRANgeo BP-

Metal deck with FIBRANgeo BP 70 boards and waterproofing


membrane on top.

FIBRANgeo SI 080 TRAPEZOID


The trapezoid elements FIBRANgeo SI-080 TRAPEZOID rockwool NEW
have been specially developed for installation in the channels (valleys) of
the trapezoid metal roof or panel sheets, thus providing extra thermal
insulation and increased mechanical integrity of the insulation system. The
elements are offered in standard dimensions or cut-to-measure according to
project.

FIBRANgeo ROOF solution: boards with asphaltic


membrane
FIBRANge Thickness Packages Quantity Thermal Tensile Thermal Point Load Compressive Reaction
/pallet Resistance R Strength Conductivity λ Strength to Fire
[mm] /pallet 2 2
(kPa) (W/mK) (PL5) (CS10) (kPa) (EN 13501-
o 40 20 86,40 1,05
(N) 1)
50 20 72,00 1,35
BP-50 ΒΙΤ
bituminous coating 60 20 57,60 1,60
15 0,037 600 50 F
Boards with 80 20 43,20 2,15
10 0 16 34,56 2,70
120 20 28,80 3,20

Board dimension: 1200 x 1000 mm

Thickness Packages Quantity Thermal Tensile Thermal


/pallet Resistance R Strength Conductivity λ Point Compressive
Strength Reaction
to Fire
[mm] /pallet 2 2
(kPa) (W/mK) (PL5)Load
FIBRANge 40 20 86,40 11,,00
(N) (CS10) (kPa)
1)
(EN 13501-
50 20 72,00 25
obituminous coating 60
80 20
20 57,60
43,20 21,50
,05 20 0,039 700 70 F
BP-70 ΒΙΤ 10 0
120
24
20
34,56
28,80
2,55
3,05
Boards with

Board dimension: 1200 x 1000 mm


11
Flat Roofs
Stonewool insulation boards for

FIBRANgeo
BP-30

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Point Load
(PL5)
Compressive
Strength
Reaction
to Fire
2
(kPa) (W/mK) (CS10) (kPa) (EN 13501-1)
BP-40 40 30 36,00 1,00
(N)

50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05 20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.

FIBRANgeo
BP HD

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Point Load
(PL5)
Compressive
Strength
Reaction
to Fire
2
(kPa) (W/mK) (CS10) (kPa) (EN 13501-1)
BP-80 40 30 36,00 1,00
(N)

50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05 20 0,039 800 80 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.

FIBRANgeo
BP-80 ΒΙΤ
bituminous facing

12
Complementary products

FIBRANskin
membranes
FIBRANskin membranes
provide vapour control
and waterproofing

FIBRANfilter FIBRANskin FIBRANskin BARRIER


SEAL

FIBRANxps 300 FIBRANxps 500 FIBRANxps 700 FIBRANxps


INCLINE
Thermal insulation boards made Thermal insulation boards made Thermal insulation boards made
with factory-made inclination.
Thermal insulation boards
D
high mechanical properties and very high mechanical properties extremely high mechanical
of extruded polystyrene, with of extruded polystyrene, with of extruded polystyrene, with
λ = 0,034 W/mK
minimum water absorption. and minimum water absorption. properties and minimum water
absorption.
D
0,034 W/mK, thickness >60 mm 0,034 W/mK, thickness >60 mm
λD = 0,033 W/mK, thickness ≤60 mm λD = 0,033 W/mK, thickness ≤60 mm
λ = 0,035 W/mK

• Smooth Surface • Board dimension:


For more information on FIBRANxps products and solutions, please refer to the XPS catalogue: 100 FIBRANxps extruded polystyrene products
13
FIBRANgeo PITCHED ROOF solution: Pitched roof with continuous
Pitched Roofs
insulatio
Thermal Tensile Thermal Compressive Reaction
FIBRANg Thickness Packages
[mm] /pallet
m2/
pallet
Resistance
(m2K/W)
R Strength
(kPa)
Conductivity λ
(W/mK)
Point Load
(PL5)
Strength
(CS10) (kPa)
to Fire
(EN 13501-
eo 40 12 0 86,40
1)
1,10
(N)

BP-30 50
60
96
80
69,12
57, 60
1,35
1,65
80 56 40,32 2,20
12 00
10 40
48 328,80
4,56 32,,75
30
10 0,036 400 30 A1
140 36 25,92 3,85
16 0 28 20,16 4,40
18 0 28 20,16 5,00
200 24 17,28 5,55
Board dimension: 600 x 1200 mm
Stonewool insulation boards for

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal R
Resistance Tensile
Strength Thermal λ
Conductivity Point Load
(PL5)
Compressive
Strength Reaction
to Fire
BP-50
o (m2K/W) (kPa) (W/mK)
(N)
(CS10)
(kPa)
(EN 13501-
1)
40 12 0 86,40 1,05
50 10 0 72,00 1,35
60 80 57, 60 1,60
800
10 60
48 43,20
34,56 2,15
2,70 15 0,037 600 50 Α1
12 0 40 28,80 3,20
140 36 25,92 3,75
160 28 20,16 4,30
Board dimension: 600 x 1200mm. Also available in dimensions 1000 x 1200 mm and thicknesses greater than 160 mm

FIBRANgeo PITCHED ROOF


solution:
Pitched roof with insulation
between timber rafters and joists
The insulation layer is placed between the rafters or joists, and it
only partially supports the weight of the pitched roof. The single or FIBRANgeo B-570
double layer of stonewool is placed orthogonally between the FIBRANgeo B-001

timber frame. The solution also consists of FIBRANskin membranes


for waterproofing and vapour control. The total thickness and
specific choice of stonewool panel type depends on the required
thermal resistance, compression strength, potential dynamic loads
and their distribution on the surface.

FIBRANge Thickness
[mm]
Packages
/pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ Point Load
(PL5) (N)
Compressive
Strength
Reaction
to Fire
B-001
o 20 240 172,80
(m2K/W)
0,60
(kPa) (W/mK
)
(CS10)
(kPa)
(EN 13501-1)

30 160 115,20 0,90 5 5


40
50 112
96 80,64
69,12 1,20
1,50 (spessore 0,033 1 A1
60 80 57,60 1,80 80 mm)
80 56 40,32 2,40 10
100 48 34,56 3,00
Board dimension: 600 x 1200 mm

Thickness Packages m2/ Thermal Tensile Thermal Compressive Reaction


Point Load
Resistance
(m2K/W)R Strength Conductivity λ Strength to Fire
B-001
FIBRANge [mm]
30
/pallet
160
pallet
115,20 0,90
(kPa) (W/mK) (PL5)
(N)
(CS10) (kPa) (EN 13501-

XA
o 40
50 120
96 86,40
69,12 1,20
1,50 10
(spessore 0,033
1)

0,95
80
60 56
80 40,32
57,60 2,40
1,80 50 mm)
100 48 34,56 3,00 10 A1

Board dimension: 600 x 1200 mm


Thickness Packages m2/ Thermal Tensile Thermal
Point Load
Resistance R Strength Conductivity λ Strength to Fire
B-001 [mm]
30
/pallet
160
pallet
115,20
(m2K/W)
0,85
(kPa) (W/mK)
(PL5)
(N)
Compressive
(CS10)
(kPa)
Reaction
(EN 13501-
1)
10
AL
FIBRANge 50
40 100
120 72,00
86,40 1,40
1,10 (spessore 0,035 0,95
60 80 57,60 1,70 50 mm)
o 80 60 43,20 2,25
20 A1

Board dimension: 600 x 1200 mm


14
n under timber
rafters
The insulation layer is placed underneath the
rafters and it supports the weight of the pitched
roof. It must have the necessary high mechanical
properties which FIBRANgeo BP-30 or FIBRANgeo
BP-50 provide. The solution also consists of
FIBRANskin membranes for waterproofing and
vapour control. This application is mainly used in
residential buildings, new and renovation projects.
The specific choice of stonewool panel type
depends on the required thermal
resistance, compression strength,
potential dynamic loads and their
distribution on the surface.

FIBRANgeo BP-30
FIBRANgeo BP-50

FIBRANgeo PITCHED ROOF solution: Pitched roof with insulation on attic


ceiling lining
The insulation layer is placed internally in the attic and it doesn’t support any
layer of plasterboard (FIBRANgyps). The solution also consists of FIBRANskin
membranes for waterproofing and vapour control or of a stonewool product with
facing (kraft paper or aluminium craft paper foil reinforced with fiberglass mesh).
The total thickness and specific choice of stonewool panel type depends on the
required thermal resistance and available ceiling space, while lower mechanical
strengths are required here.

MW-EN 13162-T4 -WS-WL(P)-MU1-AW1-AFr15


FIBRANgeo R-040 Quantity per Thermal Resistance R
Thickness [mm] Width [mm] Length [mm]
• Thermal Conductivity λ D: 0.035 W/mK package [m2] (m2K/W)
• Air Flow Resistivity: 30 kPa s/m2 30 1000 10000 10 0,85
• Sound absorptionς α =1 at 50 mm 40 1000 8000 8 1,10
w
thickness 50 1000 6000 6 1,40
60 1000 6000 6 1,70
• A1 - Non - combustible
MW-EN 13162-T4 -WS-WL(P)-MU1-AW1-AFr30
FIBRANgeo R-050 Quantity per Thermal Resistance R
Thickness [mm] Width [mm] Length [mm]
• Thermal Conductivity λ D: 0.035 W/mK package [m2] (m 2K/W)
• Air Flow Resistivity: 30 kPa s/m2 30 1000 9000 9 0,85
40 1000 8000 8 1,10
• Sound absorptionς αw=1 at 50 mm 50 1000 6000 6 1,40
• A1 - Non - combustible 60 1000 6000 6 1,70

Complementary products

FIBRANskin
membranes
FIBRANskin membranes
provide vapour control
and waterproofing

FIBRANfilter FIBRANskin FIBRANskin BARRIER


SEAL

15
FIBRANgeo ETICS solution: External Thermal Insulation Composite
External Thermal Insulation System ETICS
Systems Bricks

The most efficient method of thermal insulation of the façade of


the building is by installing the insulating material on the
exterior side of the wall. In that way, the thermal bridges are
minimized, thus providing maximum energy savings while at the Plaster

same time the building is protected from wear and tear due to
external conditions. This construction takes advantage of the
thermal capacity of the building elements (columns, beams, walls),
and improves the thermal behavior along the day cycle. Mechanical fixing plugs

ETICS (External Thermal Insulation Composite System) is an


excellent way to renovate and improve the appearance of an old
building while at the same time upgrading its thermal
performance. FIBRANgeo BP-
ETICS
Armored shaving and coating
Possible starting skirt
Colored siloxane thickness
in FIBRANxps ETICS
GF

MW-EN 13162-T5-CS(10)30-TR10-WS-WL(P)-MU1-AW0,95-AFr60
FIBRANgeo BP- Thickness Boards Quantity per Packages Quantity per
Thermal
Resistance R
ETICS [mm] per package package [m2] per pallet pallet [m2]
(m2K/W)
30 8 4,80 20 96,00 0,85
40 7 4,20 18 75,60 1,10
50 6 3,60 16 57,60 1,40
60 5 3,00 16 48,00 1,70
70 4 2,40 18 43,20 2,00
80 3 1,80 20 36,00 2,25
100 3 1,80 16 28,80 2,85
Certified Product according to ETAG 004, 120 2 1,20 20 24,00 3,40
140 2 1,20 18 21,60 4,00
for use in external thermal insulation 160 1 0,60 30 18,00 4,55
composite systems (ETICS) 180 1 0,60 28 16,80 5,10
• Thermal Conductivity λ :D 0.035 W/mK 200 1 0,60 24 14,40 5,70
220 1 0,60 22 13,20 6,70
• Tensile Strength perpedicular to faces, 240 1 0,60 20 12,00 6,85
TR > 10 kPa 260 1 0,60 18 10,80 7,40
Stonewool insulation boards for

• Compressive stress > 30 kPa 280 1 0,60 18 10,80 8,00


• A1 - Non combustible 300 1 0,60 16 9,60 8,55

FIBRANgeo FREZA FIBRANgeo CAPS FIBRANgeo FASTENER


Metallic milling tool Rock-wool (or polys- Available at various
(70mm) terene) special items, lengths to accom-
68mm diameter & 15mm modate any ETICS
thickness, for perfectly thickness.
covering the holes of the fasteners.

16
FIBRANproducts ETICS
solution
Insulation products that can work together

Stonewool
FIBRANgeo BP-ETICS

FIBRANgeo
Reinforced gypsum board
FIBRANgyps NEXT

Fire barrier
FIRE BARRIER ZONE FIBRANgeo BP-ETICS Fire Barrier

FIBRANgyps NEXT

Extruded Polysterine
WET
ZONE FIBRANxps GF
ETICS
FIBRANxps
BT
FIBRANxps
300L FIBRANx
ps

BASEMENT

17
External Thermal Insulation ETICS
Stonewool insulation boards for

ET ICS system with FIBRANgeo BP-ETICS

FIBRANskin SEALsuitableBreathable membrane,


for vertical surfaces such
as ETICS and ventilated facades.
Complementary products

FIBRANxps ETICS FIBRANxps 300 FIBRANxps CAP FIBRANeps


Thermal insulation boards made Extruded polystyrene special items,
GF of extruded polystyrene, with 68mm diameter & 15mm thickness, TERMOPOR
high mechanical properties and for perfectly covering the holes of
Extruded polystyrene boards with relief
(rough) surface for improved adhesion minimum water absorption. the fasteners. FIBRANeps GRAFIT
and improved vapour diffusion. λD = 0,033 W/mK, για πάχη ≤60 mm Diameter: 68 mm,
Certified for ETIC Systems according to 0,034 W/mK, για πάχη >60 mm Thickness: 15 mm
ETAG 0,034
004. W/mK, thickness >60 mm
λD = 0,033 W/mK, thickness ≤60 mm Packing: 200 units / box

For more information on FIBRANxps products and solutions, please refer to the XPS catalogue: 100 FIBRANxps extruded polystyrene products
18
FIBRANgeo ETICS + FIBRANgyps NEXT solution: Facade
Insulation
Product description
Gypsum board covered on both sides by reinforcement made of fiberglass,
additivated with special components that make it particularly resistant to
atmospheric agents, shocks, abrasion and bending.

CE marked GM-type H1R according to UNI EN 15283-1.


Conforms to ASTM C1177 for outdoor use.

FIBRANgyps NEXT
BOARD
Gypsum board CE marked GM-type H1R
Dimensions 120 x 200 cm
Thickness 12,5 mm
Surface mass 10,00 kg/m2
Edge BA tapered edge
Thermal conductivity (10°C) λd = 0,225 W/m K
Fire reaction class A1
Specific heat cp = 1,0 theoretical value according EN 12524
Water absorption ≤ 3%
Flexural transversal breaking load ≥ 300 N
Flexural longitudinal breaking load ≥ 725 N
Dimensional variation cycles 4 days Transversal direction: 0,22 mm/m Longitudinal
23°C 50% RH / 3gg 30°C 90% RH direction: 0,03 mm/m
Mold resistance No growth

FIBRANgyps NEXT SYSTEM


components
FIBRANgyps FIBRANgyps FIBRANgyps FIBRANgyps FIBRANgyps
NEXT MESH TAPE NEXT NEXT NEXT BASE
Reinforced mesh Jointing tape For external screws Corner with mesh PROFILE
Mesh produced with glass fiber wire Adhesive tape with Self-drilling screws, length PVC corner with Base profiles
with sizing anti-alkaline, high chemical high chemical inertia, 25 and 39 mm, RUSPERT alkali-resistant mesh,
inertia, certified ETAG 004. anti-alkaline sizing, used coating that guarantees for Fibrangyps
whit e color. NEXT BOARD
for the tapered edges 500h to salt spray test.
finishing. 12,5 mm
thickness.

19
facin
FIBRANgeo VENTILATED FACADE solution: Stone-wool insulation
Ventilated Facade
with
Thermal Tensile Thermal Reaction
FIBRANg Thickness
[mm]
Packages /
pallet
m2/
pallet
Resistance
2
R Strength
(kPa)
Conductivity λ
(W/mK)
Sound
absorption a w
to Fire
(EN 13501-1)
B-570
eo YM 40 120 86,40 1,20
Panel coated with 50 96 69,12 1,50
black glass veil (60gr/m2)
60 84 60,48 1,80
80 60 43,20 2,40
100 48 34,56 3,00 1
120 40 28,80 3,60 50 0,033 (per spessore A1
>= 50 mm)
140 36 25,92 4,20
160 30 21,60 4,80
180 28 20,16 5,45
200 24 17,28 6,05
Stonewool insulation boards for

Board dimension: 600 x 1200 mm

Thickness Packages / m2/ Thermal Reaction


Tensile Thermal
FIBRANgeo [mm] pallet pallet
Resistance R Strength Conductivity λ
Sound
absorption a
to Fire
(m2K/W) (kPa) (W/mK) (EN 13501-
B-570 XA
w
30 156 112,32 0,90 1)
Panel coated
40 120 86,40 1,20
with Kraft paper 50 96 69,12 1,50 1
60 84 60,48 1,80
50 0,033 (per
>= spessore
50 mm) F
80 60 43,20 2,40
100 48 34,56 3,00

Board dimension: 600 x 1200 mm

FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
2
(kPa) (W/mK) (EN 13501-1)
B-050 YM
w

40 120 86,40 1,15


Panel coated with
black glass veil (60gr/m2) 50 100 72,00 1,45
60 80 57,60 1,75
80 60 43,20 2,35
100 50 36,00 2,95 1
30 0,034 (per spessore A1
120 40 28,80 3,50 >= 50 mm)
140 36 25,92 4,10
160 30 21,60 4,70
180 28 20,16 5,25
200 24 17,28 5,85
Board dimension: 600 x 1200 mm

FIBRANgeo Thickness Packages / m2/ Thermal


Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound Reaction
to Fire
B-050 XA [mm] pallet pallet (m2K/W) (kPa) (W/mK) absorption aw (EN 13501-1)
Panel coated 40 120 86,40 1,10
with Kraft paper 50 100 72,00 1,40 1
60 80 57,60 1,70 30 0,034 (per spessore F
80 60 43,20 2,25 >= 50 mm)
100 50 36,00 2,85
Board dimension: 600 x 1200 mm

20
g for ventilated facades

The ventilated façade is a high-performance solution for


external building walls. It is defined by the presence of an air
gap between the main body of the building and the
external “skin”, which is usually some cladding (eg. Ceramic
tiles, stone, marble, metallic panels) that is mechanically
anchored to the main structure.

Stone wool is the ideal insulating material for this


application, since it combines the high thermal insulation
with fire protection, acoustic insulation and ideal vapour
permeability. The use of a black glass fiber coating on stone
wool protects it against the possibility of wear and tear (de-
fibration) and rain infiltration.

FIBRANgeo B-050 and B-570 stonewool panels, both with


YM (black, now-woven fiberglass fleece) and XA (Kraft
paper) facings, are specially designed for this application.
Furthermore, they are A1-class fire certified, meaning they
are incombustible and thus providing the necessary fire
protection to high buildings, as required by legislation in
most European countries.
Ventilated facade with FIBRANgeo
B-570-YM

Complementary products

FIBRANskin
membranes
FIBRANskin membranes
provide vapour control
and waterproofing

FIBRANfilter FIBRANskin FIBRANskin BARRIER


SEAL

21
FIBRANgeo DRY CONSTRUCTION solution: Internal walls
Dry Construction

FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
(m2K/W) (kPa) (W/mK) (EN 13501-1)
B-030
w

30 160 115,20 0,85


40 120 86,40 1,10 1
50 100 72,00 1,40
60 80 57,60 1,70 30 0,034 (per spessore A1
>= 50 mm)
80
100 60
50 43,20
36,00 2,25
2,85
Board dimension: 600 x 1200 mm

Thermal Reaction
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Resistance
(m K/W)R
2
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
w (ENto13501-1)
Fire
(kPa) (W/mK)
B-040 40
50 120
100 86,40
72,00 1,10
1,40 1
60 80 57,60 1,70 A1
Stonewool insulation boards for

15 0,034 (per spessore


80 60 43,20 2,25 >= 50 mm)
100 50 36,00 2,85
Board dimension: 600 x 1200 mm

Thickness Packages / m2/ Thermal Tensile Thermal Sound Reaction


FIBRANgeo [mm] pallet pallet
(m K/W)R
2
Resistance Strength
(kPa) Conductivity
(W/mK) λ absorption a
w (ENto13501-1)
Fire
B-050 40
30 120
160 86,40
115,20 1,10
0,85 1
60
50 80
100 57,60
72,00 1,70
1,40 >= spessore
50 mm)
30 0,034 (per A1
100
80 50
60 36,00
43,20 2,85
2,25
Board dimension: 600 x 1200 mm

Dry construction (building construction without the use of plaster or mortar), speeds the construction process and is the most common method
for building internal separation walls. It is very common in hotels, commercial and public buildings as it offers ease and speed of construction
while allowing for easier future alterations. The key technical characteristics that a proper dry wall must offer, apart from its mechanical strength,
is acoustic & thermal insulation as well as fire protection.
FIBRANgeo B-series products are ideal for this application, as they provide high acoustic and thermal insulation, fire protection (A1 class fire
certified, meaning they are incombustible) and sufficient mechanical strength so that they retain their form and shape for the lifetime of the
construction.

FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire

B-060 (m2K/W) (kPa) (W/mK) (EN 13501-1)


w

30 160 115,20 0,85


40 120 86,40 1,10
1
50 100 72,00 1,40
60 80 57,60 1,70 35 0,034 (per spessore A1
>= 50 mm)
80 60 43,20 2,25
100 50 36,00 2,85
Board dimension: 600 x 1200 mm

FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire

B-570 (m2K/W) (kPa) (W/mK) (EN 13501-1)


w

30 156 112,32 0,90


40 120 86,40 1,20
1
50 96 69,12 1,50
60 84 60,48 1,80 50 0,033 (per spessore A1
>= 50 mm)
80 60 43,20 2,40
100 48 34,56 3,00
Board dimension: 600 x 1200 mm

FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
B-001 20 240 172,80
(m2K/W)
0,60
(kPa) (W/mK) w (EN 13501-1)

30 160 115,20 0,90


40 112 80,64 1,20 1
50 96 69,12 1,50 60 0,033 (per spessore A1
60 80 57,60 1,80 >= 50 mm)
80 56 40,32 2,40
100 48 34,56 3,00
Board dimension: 600 x 1200 mm

22
Drywall system installation with stonewall inside and
FIBRANgyps plasterboards.

ETA 13/0631
FIBRAN stud partitions and lining systems obtained
ETA 13/0631 by Instituto de Ciencias de la
Costrucciòn Eduardo Torroja de Madrid.
Complementary products

FIBRANgyps SUPER FIBRANgyps CARE® FIBRANgyps H2 13 FIBRANgyps F 13


Gypsum based board for special Special gypsum plasterboard Gypsum based board with Gypsum based board with
application, with higher strength, produced with the innovative FIBRAN additives to reduce the water additives such as vermiculite
higher surface hardness, controlled CARE Technology: neutralisation absorption rate. and glass fibers to improve core
density, reduced water absorption of air pollutants (VOC) and odors Type H2, CE marked according adhesion at high temperature for
(H1), and with additional glass fibres without releasing them back into the to UNI EN 520, one decorative fire resistance.
to improve core adhesion at high environment. Standard type A, CE green. Type F, CE marked according to
temperatures. marked according to UNI EN 520, one UNI EN 520, one decorative pink
Type DFH1IR, CE marked according decorative ivory face. No emission of face.
to UNI EN 520, one decorative light pollutants in the indoor environment
blue face. - classification A+ in accordance with
EN ISO 16000-09.

FIBRANgyps NEXT FIBRANgyps GLUE FIBRANgyps JF60 FIBRANgyps JF READYMIX


COATpowder to be mixed
Finishing Gypsum-based high density Joint filler in powder to be mixed Ready-mixed joint compound
with water, based on selected adhesive, in powder to be mixed with water for manual application, for quick and easy application,
inert, hydraulic binder and special with water for manual application. medium setting time. To be lightened by 25% compared with
additives which give the product CE marked according to EN 14496. used between 5° and 35°C. 3B CE traditional joint filler , very elastic
remarkable adhesion and elasticity. marked according to UNI EN 13963. and soft.

23
FIBRANgeo FLOORS solution: insulation under floors for improved
Floors
acoustic
Thermal Tensile Thermal Compressive Reaction
FIBRANg Thickness Packages
[mm] /pallet
m2/
pallet
Resistance R
(m2K/W)
Strength
(kPa)
Conductivity λ
(W/mK)
Point Load
(PL5)
Strength
(CS10) (kPa)
to Fire
(EN 13501-1)
eo 40 12 0 86,40 1,10
(N)
Stonewool insulation boards for

50 96 69,12 1,35
BP-30 60
80
80
56
57, 60
40,32
1,65
2,20
10 0 48 34,56 2,75 10 0,036 400 30 A1
12 0 40 28,80 3,30
140 36 25,92 3,85
16 0 28 20,16 4,40
18 0 28 20,16 5,00
200 24 17,28 5,55
Board dimension: 600 x 1200 mm

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal
Resistance
2
R
Tensile
Strength
Thermal
Conductivity λ
Point Load
(PL5)
Compressive
Strength
Reaction
to Fire

o 40 30 36,00 1,00
(N)

BP-40 50
60
24
20
28,80
24,00
1,25
1,50
80 15 18,00 2,05 20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Point Load
(PL5)
Compressive
Strength
Reaction
to Fire

BP-50
o 40 30 36,00
(m 2 K/W)
1,05
(kPa) (W/mK)
(N)
(CS10)
(kPa)
(EN 13501-
1)
50 24 28,80 1,35
60 20 24,00 1,60
80 15 18,00 2,15
15 0,037 600 50 A1
10 0 12 14,40 2,70
12 0 10 12 ,00 3,20
140 8 9, 60 3,75
160 7 8,40 4,30
Board dimension: 1200 x 1000mm. Also available in dimensions 1200 x 600 mm and thicknesses greater than 160 mm

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal
Resistance R
2
Tensile
Strength
Thermal
Conductivity λ
Point Load
(PL5)
Compressive
Strength
Reaction
to Fire

BP-70 40 30 36,00 1,00


(N)

50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05
20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.

FIBRANge Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Assorbimento
acustico a w
Reaction
to Fire
B-001
o 20 240 172,80
(m2K/W)
0,60
(kPa) (W/mK) (EN 13501-1)

30 160 115,20 0,90


40 112 80,64 1,20 1
50 96 69,12 1,50 60 0,033 (per spessore A1
60 80 57,60 1,80 >= 50 mm)
80 56 40,32 2,40
100 48 34,56 3,00
Board dimension: 600 x 1200 mm

24
behaviour

The use of FIBRANgeo B or BP series products at floating


floor applications, provide excellent sound insulation
against shock and air-transmitted sound. The high
mechanical properties of the stonewool boards ensure
the technical endurance of the constructi on.

Sound insulation of floating


floorB-571
with FIBRANgeo

Complementary products

FIBRANxpe FIBRANskin SEAL

FIBRANge Thickness Packages


[mm] /pallet
m2/
pallet
Thermal
Resistance R
2
Tensile
Strength
Thermal
Conductivity λ
Point Load
(PL5)
Compressive
Strength
Reaction
to Fire

B-051 40 30 36,00 1,00


(N)

50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05
20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.

FIBRANge Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Assorbimento
acustico a w
Reaction
to Fire
B-571
o 20 240 172,80
(m2K/W)
0,55
(kPa) (W/mK) (EN 13501-1)

30 160 115,20 0,85


40 112 80,64 1,10 1
50 96 69,12 1,40 60 0,035 (per spessore A1
60 80 57,60 1,70 >= 50 mm)
80 56 40,32 2,25
100 48 34,56 2,85
Board dimension: 600 x 1200 mm

25
HANDLING AND STORAGE
FIBRANgeo products should be stored indoors. If stored outdoors, they must be protected from
impregnation. Pallets shrink-wrapped weather tightly in PE film may be stored outside. Separate packages
should be placed on a flat pallet, not in direct contact with the ground.
If part of the product gets wet, it must be dried before installation. Stonewool dries quickly and its
insulating properties remain unchanged after drying.
FIBRANgeo products are chemically inert and do not allow the growth of micro-organisms, insects or
rodents.
Handling, loading and unloading of the products should be carried out with care, to avoid damage both
of the packaging and the boards’ edges.

APPLICATION AND PERSONAL PROTECTION


For the selection and application of FIBRANgeo products all design requirements should be taken into
consideration.
FIBRANgeo products should be protected from impregnation, prior to and during application. The packaging
film should be removed with care just before installation.
Working areas should be kept clean. Unnecessary or extensive contact of the skin and eyes with product
off-cuts, fibres and dust should be avoided, and protective wear should be used (gloves, goggles, hats).
Sufficient ventilation of the working areas should be ensured, whilst power cutting tools should always be
provided with a mechanical system of dust intake.
Stonewool products are not considered hazardous waste. Waste disposal should be carried out according
to State and Local regulations.

FIBRAN reserves the right to alter or amend product specifications without notice. The information included
in this publication is correct to the best of our knowledge at the time of printing. Whilst FIBRAN will
endeavour to ensure publications are up to date, it is the users’ responsibility to check with the company
the validity of the information prior to materials use.

26
What does FIBRAN stand for?

FIBRAN stands for quality. We manufacture products for thermal & sound insulation, as
well as fire protection, taking great care to ensure that our materials meet the technical
requirements and declared values.

FIBRAN stands for honesty. We respect the architect, the engineer, the constructor,
the applicator and the owner of the project by providing truthful declarations after
thorough testing and examination of the products. Designers and energy auditors can
count on our technical data, constructors can trust our materials.

FIBRAN stands for ethos. We value morality and fair trade practices by going into
great lengths to honor agreements, pay our people, partners and suppliers on time,
follow and respond to claims, meet all our obligations. We stand next to the user of
our product after the sale.

FIBRAN stands for family. Even after growing to an international organization with
production plants at six countries, the company retains a strong family core and values
that spread through its people.

FIBRAN stands for future. We design solutions for the building of tomorrow. We
research technologies for the years to come. We prepare answers to the challenges of
the next decade and participate in multiple International Associations. And we support
our people and partners for all to grow together.

27

You might also like