Fibr An S.A. I Nsula Tion M A T Erials I Ndustr y
Fibr An S.A. I Nsula Tion M A T Erials I Ndustr y
FIBRAN
gΤhermal
e o insulation, sound insulation
Stonewool
02
fibrous material, widely recognised
l as its excellent performance towards fire protection.
03
The power of nature
Advantages of FIBRANgeo
FIBRANgeo stonewool is the material which offers insulation against undesired thermal losses & gains, fire
hazards and noise pollution! Therefore, with the use of a single insulation material, the building is shielded
against all these problems/issues/factors, while at the same time achieving excellent passive ventilation and
remaining environmentally friendly.
04
FIBRANgeo stonewool is 100% compatible with other
insulating materials, such as FIBRANxps or
FIBRANeps. All these materials can be used at the
same project, to satisfy the technical requirements of
different building applications such as basement, walls,
pitched roof and terrace.
Resistant to vibrations
Does not allow the development of micro-organisms, insects or rodents
Recyclable
05
Applications of FIBRANgeo Facings of FIBRANgeo
FIBRANgeo products are suitable for use in all building types. FIBRANgeo products are available with
They are suitable for the insulation of all building elements, such as the following standard facings to meet
walls, floors, ceilings, roofs, terraces, building equipment, particular application requirements:
mechanical installations, sound insulating and passive fire
prevention systems. AX: Aluminium kraft paper foil reinforced with fibreglass mesh
AL: Aluminum foil reinforced with fibreglass mesh
ROOFS
FACAD YM: Black non-woven fibreglass fleece
E DRY YA: White non-woven fibreglass fleece
FLOO XA: Kraft paper
RS BIT: Bitumen coating
ROLLS PB: Plastic
For selection of the suitable product type, please refer to the Bag
Product Selector by Application on page 07.
FIBRAN Solutions
FIBRANtools
FIBRAN offers solutions for each application: FIBRAN offers a wide range of quality tools, for DRY construction
FIBRANroof, FIBRANwall, FIBRANfloor, FIBRANdry & insulation applications.
Packaging of FIBRANgeo
FIBRANgeo products are supplied packed. The appropriate
number of boards and individual rolls are shrink-wrapped in
PE film, in packages and rolls. The appropriate number of
packages is shrink-wrapped weather tightly, with an extra outer
PE film, in pallets. For details about packages and
pallets for particular FIBRANgeo product types, please refer to
pages 08 to 20 (www.fibran.gr).
Types of FIBRANgeo
The standard unfaced FIBRANgeo product range is:
Boards with knit fibres and 4-sides L-cut: BP 50-L, BP HD-L, BP 70-L
Boards with knit fibres: BP series ΒP 80, BP 70, BP HD, BP 50, BP 40, BP 30, BP-ETICS
Boards: B series B-001, B-570
Rolls: R series R-050, R-040,
Loose fill: XS-LOOSE
06
Certifications of FIBRANgeo
0751
All FIBRAN geo st one w ool insu la tio n pr oduc ts meet the QUALIT Y and SAFE T Y r equir ements of the E ur opean Stand ar ds .
CE certification
All FIBRANgeo stonewool insulation products conform to the European Regulation (CPR) 305/2011, which replaced the European Directive 99/91/ EEC. In
compliance with CPR, all types of FIBRANgeo stonewool products hold the CE marking and are in conformity with the European Norm EN13162, which
refers to mineral wool insulation products used in building applications. Also, FIBRAN has created the Declaration of Performance for every product type
which can be downloaded from: http://www.fibran.gr/dop. In accordance with the abovementioned European Νorm, every insulation product acquires a
designation code, which declares its technical characteristics.
For example:
MW - EN 13162 – Ti - CS(10)i – TRi - PL(5)i – CPi – WS - WL(P) – MUi – SDi - AFri – AWi
• MW – Factory made mineral wool insulation material, industrially manufactured from molten rock, slag or glass.
• EN 13162 – The European Standard number.
• Ti – Thickness Tolerances. Classes for thickness tolerances from the nominal thickness (e.g. Class T4 : - 3mm + 5mm).
• CS(10)i – Minimum compressive stress at 10% thickness deformation (kPa).
• TRi – Minimum tensile strength perpendicular to faces (kPa).
• PL (5)i – Point Load (N). Minimum compressive load (applied on a small area of 50 cm²) at 5 mm thickness deformation.
• CPi – Compressibility (mm). The max. difference between the thickness dL, under a light load of 0.25 kPa, and the thickness dB, under a load of 2 kPa (+ - 48 kPa).
• WS – Short Term Water Absorption (kg/m²) with partial immersion in water for 24 hours <1 kg/m².
• WL(P) – Long Term Water Absorption (kg/m²) with partial immersion in water for 28 days <3 kg/m².
• MUi – Water Vapour Transmission. The maximum ratio (factor μ) of water vapour diffusion resistance of the material to the resistance of an equal
thickness of air.
• SDi – Dynamic Stiffness (MN/m³). The maximum ratio (factor s’) of dynamic compressive stress to dynamic change in thickness.
• AFri – Air flow resistivity (kPa s/m²). The minimum air flow resistance coefficient of 1m thickness material >5 kPa s/m².
• AWi -Weighted Sound Absorption Coefficient. The value of the sound absorption coefficient αw in the frequency of 500Hz, measured on the
standard weighted sound absorption curve.
The thermal conductivity λD and the thermal resistance RD, as well as the fire classification should also be declared.
• λD - Declared Thermal Conductivity (W/mK). The maximum expected nominal thermal conductivity during the material’s working life, at mean
temperature 10 °C (greater than the test results), in accordance with EN 13162.
Thermal conductivity λ (W/mK) is the heat amount transmitted through a layer of material, with 1 m² surface area and 1 m thickness, when a constant
temperature difference of 1 K is maintained between the layer’s faces.
• RD - Declared Thermal Resistance (m²K/W ). The minimum expected nominal thermal resistance during the material’s working life, at mean
temperature 10 °C (less than the test results), in accordance with EN 13162.
Thermal resistance R (m²K/W) is the ratio of the material’s thickness d to the material’s thermal conductivity λ.
• Fire Classification – Building materials are classified depending on their reaction to fire in Classes A1 (non-combustible), A2, B, C, D, E to F (no
performance determined), in accordance with EN 13501-1.
The quality of FIBRANgeo products is assured in accordance with EN 13162 and EN 13172 standards.
These standards establish the type and frequency of measurements executed both by recognized and independent institutions, as well as
by FIBRAN laboratories.
0751
EUCEB Certification
All FIBRANgeo stonewool insulation products also carry the certification mark EUCEB (European Certification Board for Mineral Wool Products). EUCEB is
an independent organisation whose procedures ensure compliance of mineral wool insulation products with the Directive’s 97/69/EC, Note Q, regarding their
fibres biosolubility and their non-classification as ‘carcinogenic’ materials.
Moreover, according to EC Regulation 790/2009 (August 10, 2009) stonewool insulation products are no longer classified as products causing skin irritation
(R38).
The quality management system of FIBRAN S.A. complies with EN ISO 9001:2008 for the design and manufacture of Mineral Wool (MW), as certified by
the independent body TÜV NORD CERT, with initial Certificate Registration No. 04 100 960680.
FIBRAN S.A. shall not be held liable for any damage caused by improper use of the products, transportation, storage and handling.
07
Pannelli in lana di roccia per l’edilizia
according to ΕΝ 13162 FIBRANgeo
BP - ΕTICS PLUS
NE NE NE NE
W W W W
EN Standard
BP - ΕTICS
BP HD-L
BP 70-L
BP 50-L
R - 050
R - 040
B - 002
B - 571
Β - 051
B - 001
B - 570
B - 050
B - 040
B - 030
BP HD
BP 80
BP 70
BP 50
BP 40
BP 30
Type
Unit
Symbol
Product
Technical data
30- 30- 30- 30- 30- 30- 30- 30- 30- 30- 40- 20- 20- 20- 20- 30- 40- 40- 40-
Thickness dN mm 30-60 30-60 EN
200 200 200 200 200 200 200 200 200 200 200 150 200 200 200 200 200 200 200
823
Tensile strength
parallel to faces σt kPa - - - - - - - - - - - - - - - 14 12 10 5 5 EN
1608
Weighted sound dN mm - 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
absorption coefficient EN ISO 354
(αw) EN ISO
AWi - - 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 1 1 1 1 1 1 1
11654
dN mm - 50 50 40 40 50 50 50 50 - 50 80 50 80 - - - - - -
Dynamic stiffness EN 29052-
(s’) SD MN/m3 - 35 35 32 32 27 20 30 30 - 23 9 10 5 - - - - - - 1
i
08
NEW NEW NEW NEW
BP 70 BP 70-L BP 50 BP 50-LBP 80
Product Type
PRODUCT SELECTOR FIBRANgeo
Application Area
FLAT
ROOFS
External insulation of concrete roof / steel deck with polymer
waterproofing membrane on insulation • • • • • • • • • • •
External insulation of concrete roof / steel deck with bitumen
waterproofing membrane on insulation •
Insulation on roof with floating concrete screed • • • • • • • • • • • •
Exposed internal insulation of steel deck •
PITCHED
ROOFS
Metal stonewool composite roof panel • • • • • • • • •
Twin-skin metal roof cladding (on site construction) with core
insulation • • • • • • •
Insulation between roof frame elements (rafters, beams, joists) • • • • • • • • • • •
Insulation on attic ceiling lining • • • • • • • • • • •
PILOTIS -
CEILINGS
Pilotis external thermal insulation composite system (ETICS) • •
DRY CONSTRUCTION
L = with NEW L-
CUT
Product Selector presents the most indicative building solutions. For any other solution please contact the technical support
department of FIBRAN S.A.
09
FIBRANgeo ROOF solution: single layer up to 300 mm
Flat Roofs
Thickness Packages Quantity Thermal Tensile Thermal Point Load Compressive Reaction
/pallet Resistance R Strength Conductivity λ Strength to Fire
[mm] /pallet (PL5)
FIBRANgeo 40 20
[m2]
86,40
(m2K/W)
1,05
(kPa) (W/mK) (N) (CS10) (kPa) (EN 13501-1)
BP-50 50
60
20
20
72,00
57, 60
1,35
1,60
70
80 24
20 51,84
43,20 12,15
,85
FIBRANgeo 10 0 16 34,56 2,70 15 0,037 600 50 A1
BP-50 120 20 28,80 3,20
Stonewool insulation boards for
FIBRANgeo Thickness
[mm] Packages
/pallet
Quantity
/pallet
2
Thermal R
Resistance
2
Tensile
Strength Thermal λ
Conductivity Point
(PL5)Load
(N)
Compressive
Strength Reaction
to Fire
40 20 86,40 1,00
50 20 72,00 1,25
FIBRANg 60
70
20
22
57, 60
47, 52
1,50
1,75
eo 80
10 0
20
24
43,20
34,56
2,05
2,55 20 0,039 700 70 A1
BP-70 L 12 0
140
20
36
28,80
25,92
3,05
3,55
16 0 28 20,16 4,10
18 0 28 20,16 4,60
200 24 17,28 5,10
Board dimension: 1200 x 1000 mm. Thickness up to 160mm available on request.
10
FIBRANgeo ROOF solution: Metal deck with FIBRANgeo BP-
50,
Stonewool FIBRANgeo BP-
FIBRANgeo
BP-30
50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05 20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.
FIBRANgeo
BP HD
50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05 20 0,039 800 80 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.
FIBRANgeo
BP-80 ΒΙΤ
bituminous facing
12
Complementary products
FIBRANskin
membranes
FIBRANskin membranes
provide vapour control
and waterproofing
BP-30 50
60
96
80
69,12
57, 60
1,35
1,65
80 56 40,32 2,20
12 00
10 40
48 328,80
4,56 32,,75
30
10 0,036 400 30 A1
140 36 25,92 3,85
16 0 28 20,16 4,40
18 0 28 20,16 5,00
200 24 17,28 5,55
Board dimension: 600 x 1200 mm
Stonewool insulation boards for
FIBRANge Thickness
[mm]
Packages
/pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ Point Load
(PL5) (N)
Compressive
Strength
Reaction
to Fire
B-001
o 20 240 172,80
(m2K/W)
0,60
(kPa) (W/mK
)
(CS10)
(kPa)
(EN 13501-1)
XA
o 40
50 120
96 86,40
69,12 1,20
1,50 10
(spessore 0,033
1)
0,95
80
60 56
80 40,32
57,60 2,40
1,80 50 mm)
100 48 34,56 3,00 10 A1
FIBRANgeo BP-30
FIBRANgeo BP-50
Complementary products
FIBRANskin
membranes
FIBRANskin membranes
provide vapour control
and waterproofing
15
FIBRANgeo ETICS solution: External Thermal Insulation Composite
External Thermal Insulation System ETICS
Systems Bricks
same time the building is protected from wear and tear due to
external conditions. This construction takes advantage of the
thermal capacity of the building elements (columns, beams, walls),
and improves the thermal behavior along the day cycle. Mechanical fixing plugs
MW-EN 13162-T5-CS(10)30-TR10-WS-WL(P)-MU1-AW0,95-AFr60
FIBRANgeo BP- Thickness Boards Quantity per Packages Quantity per
Thermal
Resistance R
ETICS [mm] per package package [m2] per pallet pallet [m2]
(m2K/W)
30 8 4,80 20 96,00 0,85
40 7 4,20 18 75,60 1,10
50 6 3,60 16 57,60 1,40
60 5 3,00 16 48,00 1,70
70 4 2,40 18 43,20 2,00
80 3 1,80 20 36,00 2,25
100 3 1,80 16 28,80 2,85
Certified Product according to ETAG 004, 120 2 1,20 20 24,00 3,40
140 2 1,20 18 21,60 4,00
for use in external thermal insulation 160 1 0,60 30 18,00 4,55
composite systems (ETICS) 180 1 0,60 28 16,80 5,10
• Thermal Conductivity λ :D 0.035 W/mK 200 1 0,60 24 14,40 5,70
220 1 0,60 22 13,20 6,70
• Tensile Strength perpedicular to faces, 240 1 0,60 20 12,00 6,85
TR > 10 kPa 260 1 0,60 18 10,80 7,40
Stonewool insulation boards for
16
FIBRANproducts ETICS
solution
Insulation products that can work together
Stonewool
FIBRANgeo BP-ETICS
FIBRANgeo
Reinforced gypsum board
FIBRANgyps NEXT
Fire barrier
FIRE BARRIER ZONE FIBRANgeo BP-ETICS Fire Barrier
FIBRANgyps NEXT
Extruded Polysterine
WET
ZONE FIBRANxps GF
ETICS
FIBRANxps
BT
FIBRANxps
300L FIBRANx
ps
BASEMENT
17
External Thermal Insulation ETICS
Stonewool insulation boards for
For more information on FIBRANxps products and solutions, please refer to the XPS catalogue: 100 FIBRANxps extruded polystyrene products
18
FIBRANgeo ETICS + FIBRANgyps NEXT solution: Facade
Insulation
Product description
Gypsum board covered on both sides by reinforcement made of fiberglass,
additivated with special components that make it particularly resistant to
atmospheric agents, shocks, abrasion and bending.
FIBRANgyps NEXT
BOARD
Gypsum board CE marked GM-type H1R
Dimensions 120 x 200 cm
Thickness 12,5 mm
Surface mass 10,00 kg/m2
Edge BA tapered edge
Thermal conductivity (10°C) λd = 0,225 W/m K
Fire reaction class A1
Specific heat cp = 1,0 theoretical value according EN 12524
Water absorption ≤ 3%
Flexural transversal breaking load ≥ 300 N
Flexural longitudinal breaking load ≥ 725 N
Dimensional variation cycles 4 days Transversal direction: 0,22 mm/m Longitudinal
23°C 50% RH / 3gg 30°C 90% RH direction: 0,03 mm/m
Mold resistance No growth
19
facin
FIBRANgeo VENTILATED FACADE solution: Stone-wool insulation
Ventilated Facade
with
Thermal Tensile Thermal Reaction
FIBRANg Thickness
[mm]
Packages /
pallet
m2/
pallet
Resistance
2
R Strength
(kPa)
Conductivity λ
(W/mK)
Sound
absorption a w
to Fire
(EN 13501-1)
B-570
eo YM 40 120 86,40 1,20
Panel coated with 50 96 69,12 1,50
black glass veil (60gr/m2)
60 84 60,48 1,80
80 60 43,20 2,40
100 48 34,56 3,00 1
120 40 28,80 3,60 50 0,033 (per spessore A1
>= 50 mm)
140 36 25,92 4,20
160 30 21,60 4,80
180 28 20,16 5,45
200 24 17,28 6,05
Stonewool insulation boards for
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
2
(kPa) (W/mK) (EN 13501-1)
B-050 YM
w
20
g for ventilated facades
Complementary products
FIBRANskin
membranes
FIBRANskin membranes
provide vapour control
and waterproofing
21
FIBRANgeo DRY CONSTRUCTION solution: Internal walls
Dry Construction
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
(m2K/W) (kPa) (W/mK) (EN 13501-1)
B-030
w
Thermal Reaction
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Resistance
(m K/W)R
2
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
w (ENto13501-1)
Fire
(kPa) (W/mK)
B-040 40
50 120
100 86,40
72,00 1,10
1,40 1
60 80 57,60 1,70 A1
Stonewool insulation boards for
Dry construction (building construction without the use of plaster or mortar), speeds the construction process and is the most common method
for building internal separation walls. It is very common in hotels, commercial and public buildings as it offers ease and speed of construction
while allowing for easier future alterations. The key technical characteristics that a proper dry wall must offer, apart from its mechanical strength,
is acoustic & thermal insulation as well as fire protection.
FIBRANgeo B-series products are ideal for this application, as they provide high acoustic and thermal insulation, fire protection (A1 class fire
certified, meaning they are incombustible) and sufficient mechanical strength so that they retain their form and shape for the lifetime of the
construction.
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
FIBRANgeo Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Sound
absorption a
Reaction
to Fire
B-001 20 240 172,80
(m2K/W)
0,60
(kPa) (W/mK) w (EN 13501-1)
22
Drywall system installation with stonewall inside and
FIBRANgyps plasterboards.
ETA 13/0631
FIBRAN stud partitions and lining systems obtained
ETA 13/0631 by Instituto de Ciencias de la
Costrucciòn Eduardo Torroja de Madrid.
Complementary products
23
FIBRANgeo FLOORS solution: insulation under floors for improved
Floors
acoustic
Thermal Tensile Thermal Compressive Reaction
FIBRANg Thickness Packages
[mm] /pallet
m2/
pallet
Resistance R
(m2K/W)
Strength
(kPa)
Conductivity λ
(W/mK)
Point Load
(PL5)
Strength
(CS10) (kPa)
to Fire
(EN 13501-1)
eo 40 12 0 86,40 1,10
(N)
Stonewool insulation boards for
50 96 69,12 1,35
BP-30 60
80
80
56
57, 60
40,32
1,65
2,20
10 0 48 34,56 2,75 10 0,036 400 30 A1
12 0 40 28,80 3,30
140 36 25,92 3,85
16 0 28 20,16 4,40
18 0 28 20,16 5,00
200 24 17,28 5,55
Board dimension: 600 x 1200 mm
o 40 30 36,00 1,00
(N)
BP-40 50
60
24
20
28,80
24,00
1,25
1,50
80 15 18,00 2,05 20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.
BP-50
o 40 30 36,00
(m 2 K/W)
1,05
(kPa) (W/mK)
(N)
(CS10)
(kPa)
(EN 13501-
1)
50 24 28,80 1,35
60 20 24,00 1,60
80 15 18,00 2,15
15 0,037 600 50 A1
10 0 12 14,40 2,70
12 0 10 12 ,00 3,20
140 8 9, 60 3,75
160 7 8,40 4,30
Board dimension: 1200 x 1000mm. Also available in dimensions 1200 x 600 mm and thicknesses greater than 160 mm
50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05
20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.
FIBRANge Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Assorbimento
acustico a w
Reaction
to Fire
B-001
o 20 240 172,80
(m2K/W)
0,60
(kPa) (W/mK) (EN 13501-1)
24
behaviour
Complementary products
50 24 28,80 1,25
60 20 24,00 1,50
80 15 18,00 2,05
20 0,039 700 70 A1
10 0 12 14,40 2,55
12 0 10 12 ,00 3,05
140 8 9, 60 3,55
160 7 8,40 4,10
Board dimension: 1200x1000mm. Thickness up to 160mm available on request.
FIBRANge Thickness
[mm]
Packages /
pallet
m2/
pallet
Thermal
Resistance R
Tensile
Strength
Thermal
Conductivity λ
Assorbimento
acustico a w
Reaction
to Fire
B-571
o 20 240 172,80
(m2K/W)
0,55
(kPa) (W/mK) (EN 13501-1)
25
HANDLING AND STORAGE
FIBRANgeo products should be stored indoors. If stored outdoors, they must be protected from
impregnation. Pallets shrink-wrapped weather tightly in PE film may be stored outside. Separate packages
should be placed on a flat pallet, not in direct contact with the ground.
If part of the product gets wet, it must be dried before installation. Stonewool dries quickly and its
insulating properties remain unchanged after drying.
FIBRANgeo products are chemically inert and do not allow the growth of micro-organisms, insects or
rodents.
Handling, loading and unloading of the products should be carried out with care, to avoid damage both
of the packaging and the boards’ edges.
FIBRAN reserves the right to alter or amend product specifications without notice. The information included
in this publication is correct to the best of our knowledge at the time of printing. Whilst FIBRAN will
endeavour to ensure publications are up to date, it is the users’ responsibility to check with the company
the validity of the information prior to materials use.
26
What does FIBRAN stand for?
FIBRAN stands for quality. We manufacture products for thermal & sound insulation, as
well as fire protection, taking great care to ensure that our materials meet the technical
requirements and declared values.
FIBRAN stands for honesty. We respect the architect, the engineer, the constructor,
the applicator and the owner of the project by providing truthful declarations after
thorough testing and examination of the products. Designers and energy auditors can
count on our technical data, constructors can trust our materials.
FIBRAN stands for ethos. We value morality and fair trade practices by going into
great lengths to honor agreements, pay our people, partners and suppliers on time,
follow and respond to claims, meet all our obligations. We stand next to the user of
our product after the sale.
FIBRAN stands for family. Even after growing to an international organization with
production plants at six countries, the company retains a strong family core and values
that spread through its people.
FIBRAN stands for future. We design solutions for the building of tomorrow. We
research technologies for the years to come. We prepare answers to the challenges of
the next decade and participate in multiple International Associations. And we support
our people and partners for all to grow together.
27