A319/320/321
30VU
COCKPIT FWD.CABIN AFT.CABIN
ECON FLOW HOT AIR
FAULT
A A
ON OFF
I I
R COLD HOT COLD HOT COLD HOT R
PACK 1 PACK 2
FWD CABIN AFT CABIN
ZONE TEMP SENSOR GALLEY&LAVATORY C FAULT
FAULT FAULT C
SAFETY PACK 1 X BLEED PACK 2
COCKPIT EXTRACTION FAN O OFF OFF O
VALVES
. N START
RAM AIR
GND HP AUTO START
N
AVIONIC ENG 1 BLEED APU BLEED ENG 2 BLEED
FWD CARGO COMP AFT CARGO COMP D OPEN D
COMP SHUT
FAULT FAULT FAULT
OUTFLOW VALVE OFF ON ON OFF
OVHT SENSOR
(IF INSTALLED)
AEVC AIR COND M
INLET VALVE DUCT TEMP SENSOR CPC CPC
TAV TAV
TAV 1 2 ENG 1 FIRE ENG 2 FIRE
PUSH PUSH
M M M
CONT
ZONE
HOT MANIFOLD
25VU
CAB PRESS LDG ELEV AUTO 100 FT
S CABIN PRESS
RECIRCULATION TAPRV RECIRCULATION LDG ELEV DITCHING
FAN MIXER UNIT S
FAN MAN V/S CTL MODE SEL
14
AUTO P V/S FT/MIN CAB ALT
-2
FLAP A 0
PSI UP FT
FAULT 12 2
U
CAB AIR MAN T 10 2 ON 8 10
MIXER UNIT O
8 4 0 0
FILTER FILTER 6
0 0.1 2 DN
0 -100
TEMP TEMP VENTILATION
SENSOR SENSOR BLOWER EXTRACT CAB FANS
A A
FAULT
U
FAULT
U SYS 1 SAFETY
OVRD T OVRD T OFF
O O
LP GROUND CONN. VENT
INLET EXTRACT
EMERG. RAM AIR
PACK 1 PACK 2
TAT +15 C GW KG
CONT TEMP CONT TEMP SAT +15 C 14 H 05
PACK 1 PACK PACK PACK 2
1 S 2 S
T
M M
BLEED
C
COND TEMP: C
o
26 C 26 oC
C H C H
RAM
o o
105 C AIR 105 C CKPT 22 FWD 24 AFT 22
FCV FCV
M M LO HI LO HI
20 24 26
C H C H C H
S S
HOT
36 AIR
36 PSI GND PSI
o o
120 C C 120
APU
1 2
IP HP HP IP
TAT +15 C GW KG
TAT +15 oC GW 62100 KG SAT +15 C 14 H 05
oC
SAT +15 15 H 35
PNEUMATIC MANIFOLD
AIR CONDITIONING SYSTEM SCHEMATIC
H21C1BB-320/JUN02 MAINTENANCE TRAINING SAS Flight Academy
A319/320/321
TO MIXING UNIT 30VU
TO HOT AIR COCKPIT FWD.CABIN AFT.CABIN
ECON FLOW HOT AIR
MANIFOLD
WATER EXTRACTOR
FAULT
A A
ON OFF
I I
R COLD HOT COLD HOT COLD HOT R
PACK 1 PACK 2
WATER EXTRACTOR PACK OUTLET
TEMP SENSOR PACK OUTLET C
OUTLET TEMP
PNEUMATIC
C FAULT
FAULT PACK 1 X BLEED PACK 2 FAULT
SENSOR (Control) (Indication + OVHT))
SENSOR (15 C) O OFF OFF O
CONDENSER GND HP AUTO
N START
RAM AIR
START
N
REHEATER CAB. ENG 1 BLEED APU BLEED ENG 2 BLEED
PRESS D SHUT OPEN D
FAULT FAULT FAULT
OFF ON ON OFF
S ANTI-ICE
RAM AIR INLET VALVE
ACTUATOR
T
BLEED
BY-PASS
OVHT SENSOR CONTROL SENSOR
(OVHT+IND) (CTR+OVHT)
VALVE
M ENG 1 FIRE 26 o
C 26 oC
C
PNEUMATIC PUSH
OVHT SENSOR
C H C H
(230-260 C)
RAM
105 o
C AIR 105 o
C
LO HI LO HI
MAIN PRIMARY
CONT
FCV ZONE 36 PSI GND PSI 36
AIV
BPV
120 o C o
C 120
RAI
APU
FLOW CONTROL SENSORS Coldest Zone Demand
1 2
VALVE
M
PRESS TRANSD IP HP HP IP
(FLOW INDICATION)
S CONT TEMP CONT TEMP TAT +15 oC GW 62100 KG
oC
PACK 1 PACK 2 SAT +15 15 H 35
INLET PRESS TRANSD
(BY-PASS VLV CTR)
CAB.
PRESS
INLET TEMP SENSOR
(CFDS) RAM AIR INLET
ACTUATOR
(IF INSTALLED)
OZON FILTER
AIR CONDITIONING PACK SCHEMATIC
H21C2BB-320/JUN02 MAINTENANCE TRAINING SAS Flight Academy