0% found this document useful (0 votes)
141 views2 pages

KNX 8-Output Module Guide

This document provides information on the Universal Module 8 Output device, including: 1) It has 8 outputs that can each be independently configured for load control, ON/OFF switching, or PWM control. Outputs can also be paired to control shutters, blinds, motors, or fan coils. 2) It has physical specifications, wiring diagrams, installation and safety information. 3) The device is powered via KNX bus and has 50 group addresses and 63 associations. It requires programming with an ETS application and mounting on a DIN rail.

Uploaded by

Vishal Suryawani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views2 pages

KNX 8-Output Module Guide

This document provides information on the Universal Module 8 Output device, including: 1) It has 8 outputs that can each be independently configured for load control, ON/OFF switching, or PWM control. Outputs can also be paired to control shutters, blinds, motors, or fan coils. 2) It has physical specifications, wiring diagrams, installation and safety information. 3) The device is powered via KNX bus and has 50 group addresses and 63 associations. It requires programming with an ETS application and mounting on a DIN rail.

Uploaded by

Vishal Suryawani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

BO08A01KNXFI01010001.

doc
Wiring Diagram PROGRAMMING:

30 ETS programming led


31 ETS programming switch

Output Configuration for Shutter


Universal Module 8 Output
BO08A01KNX Channel Output / Function Output / Function
CH A OUT 1 ▲ (up) OUT 2 ▼(down)
Product and Applications description CH B OUT 3 ▲ (up) OUT 4 ▼(down)
CH C OUT 5 ▲ (up) OUT 6 ▼(down)
The DIN RAIL 8 Output Module BO08A01KNX is an CH D OUT 7 ▲ (up) OUT 8 ▼(down)
EIB/KNX DIN rail mounting device useful to interface
commands (e.g. push buttons) or loads (e.g. lamps) for Output Configuration for Motor Reduction Driver
any kind of applications.

Device 8 outputs on board can be configured: Channel Output / Function Output / Function
• Each output can be configured independently for CH A OUT 1 Close OUT 2 Open
load control (R1 to R8) CH B OUT 3 Close OUT 4 Open
• Each output can be configured independently for ON CH C OUT 5 Close OUT 6 Open
/ OFF or continuous switching (PWM) for Electric CH D OUT 7 Close OUT 8 Open
valves (solenoid actuators) (EV1 to EV8)
• Outputs can be configured in pairs for the
management of roller shutters and blinds; up to 4 Output Configuration for Fan Coil Actuator
Physical specifications and Dimensions
channels (Channels A to D)
• Outputs can be configured in pairs for management
• Housing: plastic Output 2 pipes 4 pipes
of Motor Reductor or for solenoid valves with 3-point
control or for ventilating grille; up to 4 channels • Dimensions: (W x H x D):: 70 x 90 x 58 mm OUT 1 Valve Heat /Cool NO Valve Heating
(Channels A to D) • Mounting width: 4 (1 SU=17,5mm) OUT 2 Valve Heat /Cool NC Valve Cooling
• Fan Coil Actuator for 2/4 pipes systems for Heating / • Weight: ca. 200 g. OUT 3 Speed 1
Cooling with 3 speed motors) (uses relay from 1 to 5) • Installation: On 35mm mounting DIN rail (EN 60715) OUT 4 Speed 2
OUT 5 Speed 3
Device is intended to be installed on DIN rail. Electrical Safety

• Pollution degree: 2 (according to IEC 60664-1) Installation Instructions


Application Program
• Protection class IP 20 (according to EN 60529):
Downloadable from website: www.eelectron.com • Safety Class III (according to IEC 61140)
• Over voltage category III (according to IEC 664-1) Device must be used for permanent indoor
Maximum number of group addresses: 50 • Bus: Safety extra low voltage - SELV installations in dry locations within distribution boards
This is the maximum number of different group • Compliant to EN50491-3 or wall boxes.
addresses the device is able to memorize. • The prevailing safety rules must be heeded.
Electromagnetic compatibility • Device must be mounted and commissioned by an
Maximum number of associations: 63
authorised installer.
This is the maximum number of associations between Compliant to: EN50491-5-1, EN50491-5-2
• The applicable safety and accident prevention
communication objects and group addresses the device
regulations must be observed.
is able to memorize. CE Mark
• The device must not be opened. Any faulty devices
Caution: there is a limit to the number of associations should be returned to manufacturer.
In accordance with the EMC and low voltage guidelines
that can be created, on the same device, between • For planning and construction of electric
transmission communications objects (i.e. inputs) and installations, relevant guidelines and regulations of
Terminals and connections the respective country are to be considered.
receiving communication objects (i.e. outputs)
If you want, on the same device, add a group address
linked to a transmission communication object (input) to Mounting and Wiring hints
a receiving communication object (output) which
already has a different group address associated, General Description
please note that you can add a maximum of 13 group The device configuration (KNX physical address
addresses of this kind for the whole device. assignment) is done by pressing the programming
push button located on the front of the housing.
Technical Specifications Connecting bus cables
Connect each single KNX/EIB bus core inside the
Power Supply terminal block observing bus polarity; slip the bus
connection into the guide slot placed on the front side
• Via Bus EIB/KNX 21..32V DC of this device and press the block down to the stop.
• Current consumption ≤ 10 mA

Outputs

• 16 A cos φ 1 - 230 Vac


• 8 A cos φ 0.6 - 230 Vac For further information please visit www.eelectron.com
• Minimum switching current: 10mA

Resistive loads: max 16 A Mmmm


Incandescent lamps: max 10 A
Motors e motor reduction units: max 10 A
Fluorescent lamps with electronic transformer: max 4 A
Fluorescent lamps (max 140 μF) max 3A (700W)

SCREW TERMINALS:
Environmental specifications
• According to EN 50090-2.2 1 COM OUT 1
• Operative temperature: 0°C + 45°C 2 OUT 1 NO contact relay 1
• Storage temperature: - 20 + 55 °C 3 COM OUT 2
• Relative Humidity (not condensing): max 90 % 4 OUT2 NO contact relay 2
5 COM OUT 3
6 OUT3 NO contact relay 3
7 COM OUT 4
8 OUT4 NO contact relay 4
9 COM OUT 5
10 OUT 5 NO contact relay 5
11 COM OUT 6 eelectron spa
12 OUT 6 NO contact relay 6 Email: [email protected]
13 COM OUT 7 Web: www.eelectron.com
14 OUT 7 NO contact relay 7
15 COM OUT 8
16 OUT 8 NO contact relay 8
BO08A01KNXFI01010001.doc
Schema Elettrico ELEMENTI DI PROGRAMMAZIONE:
30 LED di programmazione ETS
31 Tasto di programmazione ETS

Configurazione per comando motore (tapparelle)


Modulo Universale 8 Uscite
BO08A01KNX Canale Uscita / Funzione Uscita / Funzione
CH A OUT 1 ▲ (su) OUT 2 ▼(giù)
Descrizione del prodotto e suo funzionamento CH B OUT 3 ▲ (su) OUT 4 ▼(giù)
CH C OUT 5 ▲ (su) OUT 6 ▼(giù)
CH D OUT 7 ▲ (su) OUT 8 ▼(giù)
Il dispositivo BO08A01KNX è fornito di 8 uscite relè da
16A per il comando di carichi.
Configurazione per servomotore
Il dispositivo prevede che le 8 uscite a bordo possano Canale Uscita / Funzione Uscita / Funzione
essere configurati in modalità diverse: CH A OUT 1 Chiude OUT 2 Apre
• Ogni singola uscita configurato in modo CH B OUT 3 Chiude OUT 4 Apre
indipendente per controllo di carichi (OUT 1÷ 8)
CH C OUT 5 Chiude OUT 6 Apre
• Ogni singola uscita configurata in modo
CH D OUT 7 Chiude OUT 8 Apre
indipendente per controllo ON / OFF oppure
continuo (PWM) per elettrovalvole (OUT 1÷ 8)
• Uscite configurate a coppie per gestione di Configurazione per Attuatore Fan Coil
tapparelle, veneziane, etc.. per un totale di 4
Uscita 2 tubi 4 tubi
canali (CH A ÷ D)
OUT 1 Valvola risc/cond NA Valvola risc.
• Uscite configurate a coppie per gestione di Dati meccanici
servomotori con comando a 3 punti per OUT 2 Valvola risc/cond NC Valvola cond.
OUT 3 Velocità 1
elettrovalvole o lamelle di areazione per un totale • Custodia: in materiale plastico
di 4 canali (CH A ÷ D) OUT 4 Velocità 2
• Dimensioni: (alt. x larg. x prof.): 90 x 71 x 58 mm
• Uscite Out1 ÷ Out5 configurate come controllo di • Peso: ca. 200 g.
OUT 5 Velocità 3
Fan Coil (riscaldamento / condizionamento o • Montaggio: guida din / retroquadro
raffrescamento / 3 velocità) Avvertenze per l‘installazione
Sicurezza elettrica
Il prodotto si intende dedicato all’installazione su L’apparecchio deve essere impiegato per installazione
barra DIN in quadri elettrici di distribuzione BT. • Grado di inquinamento (secondo IEC 60664-1): 2 fissa in interno, ambienti chiusi e asciutti.
• Grado di protezione (secondo EN 60529): IP 20 • L’apparecchio deve essere installato e messo in
Programma applicativo ETS • Classe di protezione (secondo IEC 1140): III servizio da un installatore abilitato.
• Classe di sovratensione : III • Devono essere osservate le norme in vigore in
Scaricabile dal sito: www.eelectron.com
• Bus: tensione di sicurezza SELV materia di sicurezza e prevenzione
Numero massimo indirizzi di gruppo: 50 • Soddisfa EN50491-3 antinfortunistica.
• L’apparecchio non deve essere aperto. Eventuali
Corrisponde al numero massimo di indirizzi di gruppo
Requisiti EMC apparecchi difettosi devono essere fatti pervenire
diversi che il dispositivo è in grado di memorizzare.
alla sede competente.
Numero massimo associazioni: 63 • Rispettati EN50491-5-1, EN50491-5-2
Corrisponde al numero massimo di associazioni tra Montaggio e collegamento
oggetti di comunicazione e indirizzi di gruppo che il Marcatura CE
dispositivo può memorizzare. Descrizione generale
Conforme alla direttiva CE (edilizia abitativa e Per effettuare la messa in servizio occorre poter
Attenzione : esiste un limite al numero di associazioni industriale), direttiva sulla bassa tensione accedere al tasto “KNX Push Button” per la
che si possono creare, sullo stesso dispositivo, tra commutazione tra modo normale e modo
oggetti di comunicazione in trasmissione (per esempio Posizione indicatori ed elementi di comando programmazione che si trova tra i morsetti KNX e i
gli ingressi) e in ricezione (per esempio le uscite). morsetti ingresso.
Qualora si voglia associare un indirizzo di gruppo usato
su un oggetto di comunicazione in trasmissione (un Collegamento del cavo bus al morsetto bus
ingresso) , ad un oggetto di comunicazione in ricezione • Il morsetto Bus KNX (compreso nella fornitura) è
(una uscita) che ha già un indirizzo di gruppo adatto ad un conduttore unifilare con ∅ 0.8 mm
precedentemente associato si ricorda che è possibile
aggiungere un massimo di 13 indirizzi di gruppo di Collegamento del modulo I/O alla linea bus
questo tipo sull’intero dispositivo. • Inserire il morsetto Bus KNX, precedentemente
collegato al cavo bus, nel connettore integrato che
Dati tecnici si trova sul lato ingressi del dispositivo
• Inserire il morsetto bus fino all’arresto
Alimentazione

• Via bus EIB/KNX 21..32V DC


• Corrente assorbita ≤ 10 mA

Uscite a relè

• 16 A cos φ 1 - 230 Vac


• 8 A cos φ 0.6 - 230 Vac
• Corrente minima di commutazione: 10mA

Carichi resistivi: max 16 A Mmmm


Lampade incandescenti: max 10 A
Motori e motoriduttori : max 10 A
Lampade fluorescenti a trasf. elettronico: max 4 A
Lampade fluorescenti: (max 140 μF) max 3A (700W)

Condizioni di impiego
MORSETTI A VITE:
• Secondo norma EN 50090-2.2
1 COM OUT 1
• Temperatura operativa: 0°C + 45°C
2 OUT 1 contatto NA relè 1
• Temperatura di stoccaggio: - 20 + 55 °C 3 COM OUT 2
• Umidità relativa (non condensante): max 90% 4 OUT2 contatto NA relè 2
5 COM OUT 3
6 OUT3 contatto NA relè 3
7 COM OUT 4
8 OUT4 contatto NA relè 4
9 COM OUT 5
10 OUT 5 contatto NA relè 5
11 COM OUT 6
12 OUT6 contatto NA relè 6 Per ulteriori informazioni visitare: www.eelectron.com
13 COM OUT 7
14 OUT7 contatto NA relè 7 eelectron spa
15 COM OUT 8 Email: [email protected]
16 OUT8 contatto NA relè 8 Web: www.eelectron.com