KNX Thermostat Installation Guide

The document describes an inwall room thermostat that can be used for HVAC applications in homes and buildings. It has one binary input and one binary output relay, an LCD display, and buttons to control temperature and fan speed settings. The thermostat connects to the KNX/EIB bus for configuration and control and can be installed in a wall box or round socket.

Uploaded by

Vishal Suryawani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views2 pages

KNX Thermostat Installation Guide

The document describes an inwall room thermostat that can be used for HVAC applications in homes and buildings. It has one binary input and one binary output relay, an LCD display, and buttons to control temperature and fan speed settings. The thermostat connects to the KNX/EIB bus for configuration and control and can be installed in a wall box or round socket.

Uploaded by

Vishal Suryawani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TM11A01KNXFI04030001.

doc
Display Elements
• 1 LED red (back) for ETS programming
• 1 LCD display B/W, size 43,5X43,5 mm
Connections
Inwall Room Thermostat • Bus line:
bus terminal connector block, single core max 0,8mm Ø
TM11A01KNX –Light Grey • Output relay
TM11A11KNX – Dark Grey Screw terminal block
Conductor cross section max.1,0 mm2
TM11A21KNX – White
• Input signal (potential free)
Product and Applications description Screw terminal block
Conductor cross section max.1,0 mm2
The Inwall Room Thermostat TM11A01KNX is an EIB/KNX Max cable length: 10 meters 12 13 14 15 16
wall mounting device designed for HVAC applications in Home
Wiring Diagram
and Building installations (i.e. offices, hospitals, hotels, private Terminals and Operating Elements:
houses, etc..).
5 COM input
Do not install in bathrooms, swimming
6 Input 1 (for potential free contacts)
pools and similar environments.
7 COM Output
The device is equipped with one binary input (potential free
8 Output terminal relay 1 (NO)
contact) that can be used, for instance, to control the HVAC
9 Programming LED
units whether a window has been opened (or closed) or for a
10 Programming push button
general purpose usage and one binary output relay to control
11 Bus Connection Terminal:
fan coils or for any different purposes.
Black = bus polarity (-)
The LCD on the front side displays the following information:
Red = bus polarity (+)
• Actual temperature from 0 to 50.0 °C (or °F)
12 Set point -
• Fan coil speeds 13 Set point +
• Thermostat current status 14 Temperature Sensor
The control elements available on the front are: Physical specifications and Dimensions 15 Fan Speed -
• A push button to increase the temperature setpoint 16 Fan Speed +
• Housing: plastic
• A push button to decrease the temperature setpoint
• Colours: Light Grey (TM11A01KNX), Installation Instructions
• A push button to increase the fan coil speed
Dark Grey (TM11A11KNX)
• A push button to decrease the fan coil speed The device may be used for permanent indoor installations
White (TM11A21KNX)
The device configuration for commissioning in terms of physi- • Dimensions: (W x H x D): 110 x 78 x 39,8 mm in dry locations within wall box mounts.
cal address, group addresses and parameters is done with • Weight: approx. 80 g. WARNING
ETS ( Engineering Tool Software) through a download of the • Installation: Flash mounting in 2 or 3 modules or wall round
Application Program. box Ø60mm, 40mm deep • The device must not be connected to 230V cables
• The prevailing safety rules must be heeded.
Display and Icons • The device must be mounted and commissioned by an
authorised installer.
• Device must be installed in a single box; any other
device in the same box must be SELV.
• The applicable safety and accident prevention regula-
tions must be observed.
• The device must not be opened. Any faulty devices
should be returned to manufacturer.
• For planning and construction of electric installations, the
relevant guidelines, regulations and standards of the re-
spective country are to be considered.

Mounting and Wiring hints


Cooling Mode Heating Mode Electrical Safety
General Description
• Pollution degree : 2 (according to EN 60664-1)
Night Mode Automatic The device configuration (KNX physical address assign-
• Protection class IP20 (according to EN 60529)
(Economy) Mode ment) is done by pressing the programming push button (10)
• Safety class: II (according to EN 61140)
located in the back side of the housing. Please take care
Antifreeze • Overvoltage category: III (according to EN 60 664-1)
Thermostat OFF during installation to leave connection wires long enough in
• Bus: safety extra low voltage SELV DC 24 V order to remove the device easily from the wall box for com-
Guest in Room / Stand-by Mode • Device complies with EN50491-3 e EN60730 missioning.
Electromagnetic compatibility Connecting bus cables
Fan Coil speeds Complies with EN50491-5 e EN60730
• Connect each single KNX/EIB bus core inside the termi-
Environmental specifications nal block (11) observing bus polarity .
• Slip the bus connection block (11) into the guide slot
Application Program • Climatic conditions: complies with EN 50491-2 placed on the back side of this device and press the
• Ambient operating temperature: 0°C + 50°C block down to the stop.
Downloadable from eelectron website: www.eelectron.com • Storage temperature: - 20 + 55 °C
• Relative humidity: max 90 % without condensation Wall box mounting
Dati tecnici Use for mounting only screws included
Certification
Power Supply KNX/EIB certificate
• Via bus EIB/KNX cable
CE Mark
Do not connect input/output with voltages different In accordance with the EMC guideline and low voltage guide-
than specified line
Inputs Location and Function operating and display elements
• Number: 1 potential free contact
• Input signal voltage Vn = 5 V
• Input signal current at close contact = 1mA
Outputs
• Number: 1 relays NO 24 V AC/DC, 1A (AC1) 5

Do not connect relays to mains (230V) 6


7
eelectron spa
8 Email: [email protected]
Control Elements Web: www.eelectron.com
9
• 1 programming push button (back side)
• 1 push button to increase temperature setpoint KNX 10
(11)
• 1 push button to decrease temperature setpoint
• 1 push button to increase fan coil speed
• 1 push button to decrease fan coil speed

Mounting instructions

1 1
TM11A01KNXFI04030001.doc

• 1 tasto: per aumentare la velocità fan coil


• 1 tasto: per diminuire la velocità fan coil
Indicatori
• 1 LED rosso (posteriore) per programmazione ETS
Termostato • 1 Display LCD B/N; area visiva: mm 43,5x43,5
Collegamenti
TM11A01KNX – Grigio Chiaro
• Linea bus:
TM11A11KNX – Grigio Scuro Terminale di connessione bus, conduttore max 0,8mm Ø
TM11A21KNX – Bianco • Uscita Relè ON/OFF
Morsetti a vite, conduttore sezione max. 1,0 mm2
Descrizione del prodotto e suo funzionamento • Ingresso ON/OFF privo di potenziale
Morsetti a vite, conduttore sezione max. 1,0 mm2 12 13 15 16
Il termostato TM11A01KNX è un apparecchio EIB/KNX in ese- 14
Lunghezza massima cavi in ingresso: 10 metri
cuzione per montaggio ad incasso per il controllo della tempe-
ratura nelle applicazioni di Home e Building automation (es: Connessioni:
uffici, hotel, ospedali, appartamenti,ecc..). Schema di Connessione
5 Comune ingresso
6 Ingresso per contatti privi di potenziale
Non installare in bagni, piscine o ambienti simili. 7 Comune contatto di uscita
8 Contatto di uscita relè (NA)
L’apparecchio è dotato di un ingresso fisico ON/OFF (a poten- 11 Terminale di connessione bus:
ziale zero) che può essere usato per interfacciare un sensore - polo negativo NERO
finestra (o per un uso generico) e di una uscita relè per il con- + polo positivo ROSSO
trollo del fan coil (o per uso generico).
Sul fronte del termostato è presente un display LCD riportante Elementi di comando:
le seguenti segnalazioni: 9 LED di programmazione ETS
• indicazione della temperatura da 0 a 50.0 °C (o al corri- 10 Tasto di programmazione ETS
spondente valore °F);; 12 Set point -
• velocità fan coil 13 Set point +
• icone di stato relative alle varie funzioni del termostato. 14 Sensore temperatura
Dati meccanici e Dimensioni d’ingombro
Gli elementi di comando disponibili all’utente sono: 15 Velocità Ventola -
• Un pulsante per aumentare il setpoint di temperatura. • Custodia: in materiale plastico 16 Velocità Ventola +
• Un pulsante per diminuire il setpoint di temperatura. • Colore: Grigio Chiaro Verniciato (TM11A01KNX)
Antracite (TM11A11KNX) Avvertenze per l‘installazione
• Un pulsante per aumentare la velocità del fan coil.
Bianco (TM11A21KNX)
• Un pulsante per diminuire la velocità del fan coil. L’apparecchio deve essere impiegato per installazione fissa
• Dimensioni: (alt. x larg. x prof.): 78 x 110 x 39,8 mm
La configurazione dell’apparecchio, avviene mediante il sof- in ambienti chiusi, spazi asciutti, incassato in custodie.
• Peso: ca. 80 g.
tware ETS ( Engineering Tool Software). • Montaggio: In scatola da incasso rettangolare da 2 o 3 unità IMPORTANTE
Display e Icone modulari o in scatola tonda Ø60mm, profondità 40mm
• Il dispositivo non deve essere connesso a linee di
tensione 230 VAC.
• Rispettare le prescrizioni di sicurezza elettrica.
• L’apparecchio deve essere installato e messo in servizio
da un installatore abilitato.
• Se il dispositivo viene installato in una scatola as-
sieme ad altri apparecchi questi devono essere SELV.
• Devono essere osservate le norme in vigore in materia di
sicurezza e prevenzione antinfortunistica.
• L’apparecchio non deve essere aperto. Eventuali appa-
recchi difettosi devono essere fatti pervenire alla sede
competente.
• L’installazione deve rispettare le normative e gli stan-
Riscaldamen- dards vigenti del paese relativo.
Raffrescamento
to Sicurezza elettrica
Montaggio e collegamento
Night Mode Modo • Grado di inquinamento (secondo EN 60664-1): 2
• Grado di protezione (secondo EN 60529): IP 20 Descrizione generale
(Economia) Automatico
• Classe di protezione (secondo EN 61140): III Per effettuare la messa in servizio occorre poter accedere al
Termostato OFF Antigelo • Classe di sovratensione (secondo EN 60664-1): III tasto di programmazione (10) che si trova sul lato posteriore
• Bus: tensione di sicurezza SELV DC 24 V della custodia. In fase di installazione prevedere lunghezze
Cliente in camera (comfort) /
• Soddisfa EN50491-3 e EN60730 di collegamento dei cavi che permettano l’estrazione
Mantenimento (stand-by) dell’insieme apparecchio/telaio di montaggio dalla scatola da
Requisiti EMC incasso
Rispettati EN50491-5 and EN60730
Velocita’ Fan Coil Collegamento del termostato alla linea bus
Condizioni di impiego • Inserire il terminale di connessione al bus KNX/EIB (11),
• Secondo norma EN50491-2 precedentemente collegato al cavo bus, nella fessura
• Temperatura ambiente durante il funzionamento: 0°C to 50°C guida del morsetto bus integrato che si trova sul lato po-
Programma applicativo • Temperatura di stoccaggio: - 20 + 55 °C steriore del dispositivo.
• Umidità relativa: max 90 % • Far scorrere il morsetto bus fino all’arresto.
Scaricabile dal sito eelectron: www.eelectron.com
Omologazione Montaggio nella scatola da incasso
Dati tecnici Omologato KNX/EIB
• Per il montaggio del dispositivo nella scatola da incasso
Alimentazione Marcatura CE utilizzare esclusivamente le viti in dotazione con
• Via bus EIB/KNX Conformemente alla direttiva CE (edilizia abitativa e industria- l’apparecchio
le), direttiva sulla bassa tensione
Non collegare ingressi/uscite a tensioni diverse da Posizione indicatori ed elementi di comando
quelle previste.
Ingressi
• Numero: 1 contatto privo di potenziale
• Tensione di scansione Vn = 5V eelectron spa
• Corrente di scansione In a contatto chiuso = 1mA Email: [email protected]
Uscite a relè 5 Web:www.eelectron.c
• Numero: 1 contatto NA 24 V AC/DC, 1A (AC1) 6
7

Non collegare i relè alla tensione di rete (230V) 8


9

Elementi di comando KNX 10


(11)
• 1 tasto: per programmazione ETS
• 1 tasto: per aumentare set point di temperatura
• 1 tasto: per diminuire set point di temperatura

Istruzioni di montaggio

1 1