Guide To... : Gas Detection & Air Quality Monitoring
Guide To... : Gas Detection & Air Quality Monitoring
G uide to...
GAS DETECTION
& AIR QUALITY
MONITORING
$10USD/ CND
[Link]
Why choose CETCI?
Our pride is in quality, not quantity. Our devotion to great service and satisfied
We are dedicated to manufacturing high quality customers.
gas detection systems, including self-contained Our skilled team is dedicated to helping you find
systems, controllers and transmitters, and indoor the right solution to your particular application.
air quality (IAQ) portable instruments. To back up what we say, we will be happy to
provide customer references to anyone that is
All aspects of product design, development and interested.
manufacturing are done in-house. Therefore,
we have complete control over the products we Our passion for innovation.
manufacture from concept to final assembly. We design, develop, manufacture, sell, and
service an extensive product range of hazardous
Our products carry either CSA, UL, CE, BTL, or gas detection systems and indoor air quality
C-Tick certification or a combination. portable instruments suited for various types of
applications.
Our products are sold worldwide and have a
proven track record. Our product knowledge available at your
fingertips.
Our products are thoroughly tested and always We offer a library of product support
gas calibrated twice before leaving our facility. documentations for all our products online at
[Link]. Our informative
We carry a large inventory of replacement parts, web site contains product manuals, datasheets,
calibration gases and calibration kits. brochures, catalogs, specification sheets,
engineering drawings, sample engineering
The way we handle warranty issues, anywhere specifications, and much more.
in the world, is second to none in any industry.
We stand behind everything we sell. That’s our Want to be the first to be notified on updates?
promise to you! Simply visit [Link],
subscribe to CETCI Magazine Blog, find us on
Facebook, follow us on Twitter: @cetci, connect
with us on LinkedIn, connect with us on Flickr, or
subscribe to our RSS feed.
2 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
ABOUT CETCI Contents
Overview: Gas Detection 4
Critical Environment Technologies
Portable Indoor Air Quality 6
Canada Inc. (CETCI) is a leading Quick Application Guide
global supplier of gas detection Fixed Gas Detection System 18
systems, including self Portable Indoor Air Quality Monitors 20
contained systems, controllers Sensor Selection Matrix
by Application 21
and transmitters, and Indoor by Product 22
Air Quality (IAQ) portable Quick Selection Guide
instruments. With ongoing Gas Detection Transmitters 24
Portable Indoor Air Quality Monitors 26
product development, CETCI’s
Questions to Ask a Customer Looking for Gas Detectors 28
instruments are ensured to be Overview: Product Overview & Datasheet 29
leading edge.
Datasheets
CETCI products are sold through » Gas Detection Controllers
a network of authorized • PDC Multi-Channel Controller 32
distributors around the world. » Self Contained Gas Detectors
• GEM-II Multi-Purpose Gas Detector 36
Applications include commercial, » Gas Detection Transmitters
• AST-I Industrial Analog Transmitter 44
institutional, municipal, and light • AST-IS Carbon Dioxide Transmitter 48
industrial markets worldwide. • DST Digital Transmitter 56
• LPT Economical Transmitter 60
Areas of specialization include • PET BACnet® Transmitter 62
parking garages, refrigeration » Accessories
plants, commercial swimming • Metal Protective Guards 64
» Portable Indoor Air Quality (IAQ) Monitor
wineries and breweries, waste • YESAIR 8-Channel Air Quality Monitor 66
• YES Plus LGA 15-Channel IAQ Monitor 68
water treatment, and many more. • YESDUST 71
CETCI gas detectors are used to Industry Abbreviations & Product Acronyms 72
Glossary of Terms 74
Some of the most common Sensor Mounting Heights & Location 75
are carbon monoxide, carbon Frequently Asked Questions (FAQ )
Fixed Gas Detection Systems 76
dioxide, nitrogen dioxide, nitric
Portable Indoor Air Quality Monitors 80
oxide, ammonia, chlorine, ozone,
Product Codes 82
combustible gases like methane
and propane, oxygen, refrigerants
and more.
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 3
OVERVIEW
Gas Detection
Categories of gas detection systems are defined by the technology they use: electrochemical and metal oxide semiconductor
technologies generally detect toxic gases and catalytic and infrared sensors detect combustible gases.
ElECtroChEmiCal Solid-StatE
Toxic gas sensors & oxygen sensors Toxic & combustible gas sensors
SPECIFICITY SPECIFICITY
Specific to target gas with known cross sensitivity to Broad spectrum, non gas specific sensors with a
a small variety of gases. wide range of interfering gases & chemicals.
RAnGE RAnGE
Typically 0 - 1.0 ppm to 0 - 2,000 ppm, sensor 0 - 50% LEL (combustible gases), varies for target
dependent. toxic gases (typically 0 - 100 ppm to 0 - 2,000 ppm).
SPECIFICITY SPECIFICITY
Specific to combustible gases only in the LEL ranges Specific to target gas.
RAnGE RAnGE
0 - 100% LEL of target gas 0 - 1,000 ppm to 0 - 100% volume. Target gas,
manufacturer dependent.
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 5
SENSOR SPECIFICATION CHART
± 50 ppm /
50 ppm fr
month @ 20°C
0 - 2,500 ppm, t90 = > 30 seconds
0 - 5,000 ppm 1 ppm (68°F) ambient,
then 100 ppm @ 20°C (68°F)
± 2% full (max ± 150
up to FSD
scale @ 20°C ppm / yr)
(68°F), 1 bar
100 ppm fr
pressure, ± 500 ppm /
0 - 10,000 0 - 5,000 ppm, t90 = > 30 seconds
Carbon Dioxide (CO2)
equiv change / yr
in clean air.
No Data t90 =< 25 seconds
EC 0 - 50 ppm 1 ppm 0.5 ppm Sensitivity: 3%
Available fr 0 - 400 ppm
change / yr in
clean air (value
based on twice
per month test)
6 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Warm Up Recommended Operating
Operating Operating
Time at Calibration Life Cross Sensitivities
Temperature Humidity
Switch On Frequency (Estimated)
Alcohols @ 1,000 ppm = 0 ppm
CO2 @ 5,000 ppm = 0 ppm
CO @100 ppm = 0 ppm
Approx 2 - 2.5
0°C to 40°C 15 - 90% Hydrocarbons @ % range = 0 ppm
min (warm up 6 months 2 yrs
(32°F to 104°F) non-condensing H2 @ 10,000 ppm = 0 ppm
delay time)
H2S @ 20 ppm = 2 ppm
Cross sensitivity list not fully completed.
Sensor maybe sensitive to other gases.
CO @ 85 ppm = 0 ppm
H2 @ 3,100 ppm = 0 ppm
NO2 @ 10 ppm = 2 ppm
C3H5OH @ 25,000 ppm = 0 ppm
H2S @ 18 ppm = 10.8 ppm
Approximately
SO2 @ 18 ppm = 5.4 ppm
2 - 2.5 min
0°C to 40°C 20 - 95% Cl2 @ 0.85 ppm = 0.24 ppm
(instrument 6 months 1.5 yrs
(32°F to 104°F) non- condensing HCl @ 7.8 ppm = 1 ppm
warm up delay
HF @ 7.2 ppm = 0 ppm
time)
HCN @ 12.6 ppm = 0.7 ppm
SiH4 @ 4.3 ppm = 0.7 ppm
H2Se @0.8 ppm = 0.24 ppm
B2H6 @ 0.2 ppm = 0.28 ppm
PH3 @ 0.2 ppm = 0.24 ppm
Approx 2 - 2.5
2 yrs, 1 yr for best 0°C to 50°C 0 - 95%
min (warm up 5 - 10 yrs None
accuracy (32°F to 122°F) non-condensing
delay time)
Approx 2 - 2.5
2 yrs, 1 yr for best 0°C to 50°C 0 - 95%
min (warm up 5 - 10 yrs None
accuracy (32°F to 122°F) non-condensing
delay time)
Approx 2 - 2.5
2 yrs, 1 yr for best 0°C to 50°C 0 - 95%
min (warm up 5 - 10 yrs None
accuracy (32°F to 122°F) non-condensing
delay time)
Approx 2 - 2.5
2 yrs, 1 yr for best 0°C to 50°C 0 - 95%
min (warm up 5 - 10 yrs None
accuracy (32°F to 122°F) non-condensing
delay time)
Approx 2 - 2.5
2 yrs, 1 yr for best 0°C to 50°C 0 - 95%
min (warm up 5 - 10 yrs None
accuracy (32°F to 122°F) non-condensing
delay time)
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 7
SENSOR SPECIFICATION CHART
EC change / yr in
(for use in clean air.
H2 back- No Data
0 - 50 ppm 1 ppm 0.5 ppm t90 = < 30 seconds
ground Available Sensitivity: 3%
enviro- change / yr in
ment) clean air (value
based on twice
per month test)
monthly test.
0.1 ppm No Data t90 = < 40 seconds
EC 0 - 5 ppm 0.02 ppm
(100 ppb) Available fr 0 - 5ppm
Sensitivity:
< 0.4 ppm
change / month
in clean air with
2X / monthly test
t50 = < 20 seconds
Chlorine Dioxide
calc fr 2 minute
0.01 ppm No Data exposure time
(ClO2)
CAT No Data
0 - 100% LEL 1% LEL 1% LEL Minimal t50 = < 10 seconds
Pellistor Available
Combustibles
± 1% FSD / mth
@ 20°C (68°F) t90 = <30 seconds
No Data
IR 0 - 5% vol CH4 0.1% volume 1% vol CH4 ambient, @ 20°C (68°F)
Available
(max ± 3% of ambient
full scale / yr)
Ethylene
No Data
(C2H4)
EC 0 - 500 ppm 1 ppm 1 ppm < 5% / month t90 = < 100 seconds
Available
Oxide (C2H4O)
Ethylene
8 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Warm Up Recommended Operating
Operating Operating
Time at Calibration Life Cross Sensitivities
Temperature Humidity
Switch On Frequency (Estimated)
H2 @ 900 ppm in 900 ppm CO @ 10°C
(50°F) = < 2 ppm
H2 @ 900 ppm in 900 ppm CO @ 20°C
(68°F) = < 4 ppm
Approximately
H2 @ 900 ppm in 900 ppm CO @ 30°C
2 - 2.5 min
0°C to 50°C 15 - 90% (86°F) = < 6 ppm
(instrument 6 months 2 - 3 yrs
(32°F to 122°F) non-condensing NO2 @ 10 ppm = < 0.1 ppm
warm up delay
Cl2 @ 10 ppm = < 0.1 ppm
time)
NO @ 50 ppm = < 0.1 ppm
SO2 @ 20 ppm = < 0.1 ppm
C2H4 @ 400 ppm = < 30 ppm
NH3 @ 20 ppm = < 0.1 ppm
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 9
SENSOR SPECIFICATION CHART
No Data
EC 0 - 2,000 ppm 1 ppm 2 ppm < 2% / months t90 = < 90 seconds
Available
Hydorgen Chloride
10 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Warm Up Recommended Operating
Operating Operating
Time at Calibration Life Cross Sensitivities
Temperature Humidity
Switch On Frequency (Estimated)
Approximately
H2 = 1 - 3%
2 - 2.5 min
0°C to 50°C 15 - 90% CO = 10 - 18%
(instrument 6 months 2 - 3 yrs in air
(32°F to 122°F) non- condensing Interference from other
warm up delay
reducing gases such as alcohol.
time)
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 11
SENSOR SPECIFICATION CHART
change / yr in
clean air
0.1 ppm No Data t90 = < 25 seconds
(H2S)
change 20°C to
0.1 ppm No Data 50°C (68°F to t90 = < 20 seconds
EC 0 - 100 ppm < 0.2 ppm
(100 ppb) Available 122°F) fr 0 - 50 ppm
Sensitivity: 101
- 105% output
change @ 50 ppm
btw 20°C (68°F) &
50°C (122°F)
12 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Warm Up Recommended Operating
Operating Operating
Time at Calibration Life Cross Sensitivities
Temperature Humidity
Switch On Frequency (Estimated)
Alcohols @ 1,000 ppm = 0 ppm
CO2 @ 5,000 ppm = 0 ppm
2 minute CO @ 100 ppm = 0 ppm
Approximately Hydrocarbons @ % range = 0 ppm
2 - 2.5 min 0°C to 40°C 15 - 95% H2 @ 10,000 ppm = 0 ppm
6 months 1.5 - 2 yrs
(instrument (32°F to 104°F) non- condensing NO @ 100 ppm = -5 ppm
warm up delay NO2 @ 10 ppm = -7 ppm
time) H2S @ 20 ppm = 0 ppm
(short gas exposure in minute range;
after filter saturation: ca. 40 ppm reading)
C2H4O2 @ 100 ppm = 100 ppm
Alcohols @ 1,000 ppm = 0 ppm
2 minute
CO2 @ 5,000 ppm = 0 ppm
Approximately
CO @ 100 ppm = 0 ppm
2 - 2.5 min 0°C to 40°C 15 - 90%
6 months 1.5 yrs + Cl2 @ 1 ppm = 0.7 ppm
(instrument (32°F to 104°F) non- condensing
Hydrocarbons @ % range = 0 ppm
warm up delay
H2 @ 3,000 ppm = < 1 ppm
time) HCl @ 10 ppm = 6 ppm
SO2 @ 20 ppm = 16 ppm
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 13
SENSOR SPECIFICATION CHART
< 1% change
0 - 25% No Data t90 = < 15 seconds
EC 0.1% volume 0.1% volume in output over 3
volume Available fr 0 - 20.9%
months
0.01 ppm < 0.02 ppm No Data months @ 20°C calc fr 3 minute
EC 0 - 1 ppm
(10 ppb) @ 20°C (68°F) Available (68°F) and 30 - exposure @ 30 cc /
50% RH min flow
Phosphine (PH3)
Lower
0.01 ppm No Data
EC 0 - 5 ppm detection limit < 5% / 6 months t90 = < 30 seconds
(10 ppb) Available
< 30 ppb
Humidity
Relative
14 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Warm Up Recommended Operating
Operating Operating
Time at Calibration Life Cross Sensitivities
Temperature Humidity
Switch On Frequency (Estimated)
2 minute
Approximately
2 - 2.5 min 0°C to 55°C < 0.7% fr 0 - 95% CO2 sensitivity: 0.1% change in O2
6 months 2 yrs
(instrument (32°F to 131°F) RH @ 40°C (104°F) reading per % CO2 in 5% CO2
warm up delay
time)
CO @ 85 ppm = 0 ppm
H2 @ 3,100 ppm = 0 ppm
NO2 @ 10 ppm = 2 ppm
C3H5OH @ 25,000 ppm = 0 ppm
2 minute H2S @ 18 ppm = 13 ppm
Approximately SO2 @ 18 ppm = 6.5 ppm
2 - 2.5 min 0°C to 40°C 10 - 95% Cl2 @ 0.85 ppm = 0.29 ppm
6 months 2 yrs
(instrument (32°F to 104°F) non- condensing HCl @ 7.8 ppm = 1.2 ppm
warm up delay HF @ 7.2 ppm = 0 ppm
time) HCN @ 12.6 ppm = 0.84 ppm
SiH4 @ 4.3 ppm = 0.84 ppm
H2Se @ 0.8 ppm = 0.29 ppm
B2H6 @ 0.2 ppm = 0.34 ppm
AsH3 @ 0.2 ppm = 0.16 ppm
5 min
operational, 1 yr for best 0°C to 50°C
N/A 3 yrs + N/A
20 min max performance (32°F to122°F)
accuracy
CO @ 85 ppm = 0 ppm
H2 @ 3,100 ppm = 0 ppm
NO2 @ 10 ppm = 2.3 ppm
C3H5OH @ 25,000 ppm = 0 ppm
2 minute H2S @ 18 ppm = 8 ppm
Approximately SO2 @ 18 ppm = 7.4 ppm
2 - 2.5 min 0°C to 40°C 20 - 95% Cl2 @ 0.85 ppm = 0.1 ppm
6 months 1.5 yrs
(instrument (32°F to 104°F) non- condensing HCl @ 8 ppm = 0.45 ppm
warm up delay HF @ 7.2 ppm = 0 ppm
time) HCN @ 12 ppm = 0.77 ppm
AsH3 @ 0.16 ppm = 0.2 ppm
H2Se @ 0.8 ppm = 0.2 ppm
B2H6 @ 0.2 ppm = 0.27 ppm
PH3 @ 0.2 ppm = 0.35 ppm
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 15
SENSOR SPECIFICATION CHART
< 2% change
0.1 ppm No Data t90 = < 25 seconds
(SO2)
Neg
-5°C to 55°C No Data
Coefficient 0.1°C 0.1°C @ 25°C 0.5°C (±) < 10 seconds
Thermistor
(23°F to 131°F) Available
Total Volatile Organic Compounds
PID
Legend:
EC Electrochemical
SS Solid State
CAT Catalytic
IR Infrared
PID PhotoIonization Detector
16 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Warm Up Recommended Operating
Operating Operating
Time at Calibration Life Cross Sensitivities
Temperature Humidity
Switch On Frequency (Estimated)
5 minute
operational, 1 yr for best 0°C to 50°C
N/A 3 yrs + N/A
20 minute max performance (32°F to 122°F)
accuracy
2 minute 5 yrs
Approximately (excl
monthly to 4
2 - 2.5 min 0°C to 40°C 0 - 95% replacable Many chemicals & gases.
months (usage
(instrument (32°F to 104°F) non-condensing lamp & Refer to manual.
dependent)
warm up delay electrode
time) stack)
2 minute 5 yrs
Approximately (excl
monthly to 4
2 - 2.5 min 0°C to 40°C 0 - 95% replacable Many chemicals & gases.
months (usage
(instrument (32°F to 104°F) non-condensing lamp & Refer to manual.
dependent)
warm up delay electrode
time) stack)
Important Notes:
1. Some sensors may be calibrated with correlation gases. If you prefer to have specific sensors calibrated with the target gas, contact our factory for
availability and extra costs. Customer will have to bear the cost of the full cylinder of specialty gas plus incoming dangerous goods freight and take
ownership of the cylinder of gas remaining.
2. These specifications have been developed from data considered accurate at the time. No warranty is implied or suggested based on this data. We
accept no responsibility for errors or omissions.
3. Critical Environment Technologies Canada Inc. reserves the right to make design and specification changes without prior notice.
4. Formaldehyde sensor has high cross sensitivity to Carbon Monoxide, Alcohol & Hydrogen.
5. Combustible (flammable) gas sensors (catalytic) can be calibrated for a number of target gases. Please specify the target gas desired & we will
evaluate your request.
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 17
QUICK APPICATION GUIDE
Ammonia (NH3 )
Leak Detection GEM-B-N
Knowing Before
GEM-B-N Entering Knowing Before Entering
18 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Parkades - Gas & Diesel Engine Exhaust Repair Shops - Gas & Diesel Engine Exhaust
CO + NO2 Monitoring CO + NO2 Monitoring
Laboratories &
Research Facilities
CH2O + O2 Monitoring
PET-EFO-OO2-N
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 19
QUICK APPICATION GUIDE
Know the Air You’re Breathing...YESAIR Know the Air You’re Breathing...YES Plus LGA
20 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
SENSOR SELECTION MATRIX
by Application
APPLICATIOnS
Wastewater Facilities
Vehicle Repair Shops
Parking Structures
Indoor Air Quality
Pump Stations
Chiller Rooms
Boiler Rooms
Loading Bays
Laboratories
Warehouses
Brewiers
Wineries
Arenas
Pools
SEnSOR
GAS TYPE
TYPE
Ammonia
EC / IR
(NH3)
Carbon Dioxide
IR
(CO2)
Carbon Monoxide
EC
(CO)
Chlorine
EC
(Cl2)
Combustibles CAT
Combustibles SS
Hydrogen (H2) SS
Hydrogen (H2) CAT
Hydrogen (H2) EC
Hydrogen Sulphide
EC
(H2S)
Nitrogen Dioxide
EC
(NO2)
Ozone
EC
(O3)
Refrigerants SS
Refrigerants IR
Sulphur Dioxide
EC
(SO2)
TVOCs SS
Legend
SS Solid State EC Electrochemical CAT Catalytic IR Infrared
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 21
SENSOR SELECTION MATRIX
by Product
FIXED GAS DETECTION SYSTEMS
GEM-II
PRODUCTS
AST-IS
AST-I
DST
PET
LPT
Ammonia (NH3))
Carbon Monoxide (CO)
Carbon Dioxide (CO2)
Combustible Gases (solid state)
Combustible Gases (catalytic)
Chlorine (Cl2)
Ethylene (C2H4)
Ethylene Oxide (ETO)
Formaldehyde (CH2O)
Hydrocarbon Gases (CH4)
Hydrogen (H2)
Hydrogen Sulphide (H2S)
Methane (CH4)
Nitrogen Dioxide (NO2)
Nitric Oxide (NO)
Nitrious Oxide (N2O)
Oxygen (O2)
Ozone (O3)
Propane (C3H8)
Sulphur Dioxide (SO2)
Refrigerants
TVOCs (solid state)
TVOCs (PID)
22 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
PORTABLE INDOOR AIR QUALITY MONITORS
PRODUCTS YESAIR YES Plus LGA
Ammonia (NH3))
Arsine (AsH3)
Carbon Monoxide (CO)
Carbon Dioxide (CO2)
Combustible Gases (catalytic)
Chlorine (Cl2)
Chlorine Dioxide (ClO2)
Ethylene (C2H4)
Ethylene Oxide (C2H4O)
Fluorine (F2)
Formaldehyde (CH2O)
Hydrogen (H2)
Hydrogen Chloride (HCl)
Hydrogen Cyanide (HCN)
Hydrogen Fluoride (HF)
Hydrogen Sulphide (H2S)
Nitrogen Dioxide (NO2)
Nitric Oxide (NO)
Oxygen (O2)
Ozone (O3)
Particulates (remote)
Phosphine (PH3)
Relative Humidity
Silane (SiH4)
Sulphur Dioxide (SO2)
Temperature
TVOCs (PID)
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 23
QUICK SELECTION GUIDE
DST
Features Single or Dual Sensor Single
Available Remote Sensor Yes
Display No
Relay No
Options
Watertight Yes
Splash Guard Yes
Electrochemical Yes
PID No
24 VDC supplied by
Power Requirement
PDC controller
Relay -
C-Tick No
BTL No
Note: All CETCI’s instruments consist of RoHS compliant circuit boards.
1
Watertight: Use optional splash guard to protect sensor from direct water spray.
24 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
LPT PET GEM-II
Single Single & Dual Single & Dual
No Yes Yes
No Yes Yes
No No 2 Included
No No No
No No No
2-wire mode: 16 - 30 VDC
3-wire mode: 16 - 30 VDC
24 VDC 15 - 30 VDC or 12 - 28 VAC
4-wire mode: 12 - 30 VAC or
16 - 30 VDC
25 mA maximum 30 mA; 90 mA (with display) Approximately 125 mA
BACnet® MS / TP up to 76,800 bps
Linear 4 - 20 mA MAC address 0 - 127 DIP switch Linear 4 - 20 mA (single)
settable.
VDC two or three
18 gauge, 4-conductor, shielded VDC three-conductor shielded
conductor shielded;
network wiring (daisy-chained) VAC four-conductor shielded
VAC four-conductor shielded
Two (2) dry contact SPDT,
- -
5 amps @ 250 V each
Automatic resetting thermal Automatic resetting thermal Automatic resetting thermal
-20°C to 40°C (-4°F to 104°F) Sensor dependant -20°C to 50°C (-5°F to 120°F)
15 - 90% RH non-condensing Sensor dependant 15 - 90% RH non-condensing
No No Yes
Pending Pending No
No No Yes
No Pending Yes
No Yes No
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 25
QUICK SELECTION GUIDE
YESAIR
Relative Humidity Sensor Yes
Features
Temperature Sensor Yes
Available
YESDUST Compatible Yes
Carbon Dioxide (CO2) Yes
Electrochemical Yes
Sensor Yes
Catalytic
Technology
Infrared Yes
PID Yes
Alkaline, AA x 3
Optional:
Memory Removable Internal SD Flash Card
Warm-Up Time Approximately 3 minutes
Operating Temperature 5°C to 50°C (41°F to 122°F)
Environmental
Humidity 0% to 95% RH non-condensing
CE Yes
26 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
YES Plus LGA
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 27
QUESTSIONS TO ASK
4. Are there any other sources of toxic or combustible gases in the area to be monitored?
This will determine the potential for cross-sensitivty of the toxic sensor and false alarms.
6. Do you require some type of control? Such as dry relay contacts, analog output signal or
quantitative digital display?
7. What do you want to do when the sensor detects the presence of unsafe levels of the target
gas?
Eg. Activate exhaust or make-up air fans, activate visual and / or audible alarms, etc.
28 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
OVERVIEW
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 29
OVERVIEW
30 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
PORTABLE INDOOR AIR QUALITY MONITORS
YESAIR Eight Channel Air Quality Monitor 66
» 8 sensor capacity
» > 30 plug & play sensor choices
70
71
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 31
Controllers - GAS DETECTION DATASHEET
PDC Multi-Channel Controller
TECHnICAL DRAWInG
Functions that can be set include relay assignment, time delays on make shall have 8 on board relays. System wiring shall be 4 wire digital network (2 low voltage
or break, complex zoning, sensor types and ranges, alarm set points and power wires and a twisted pair for the communication bus). System power requirement is
much more. The controller has a two line backlit LCD display that actively 90 - 240 VAC, 47 to 63 Hz. The system shall be CSA / UL tested for electrical safety.
scrolls through all programmed channels and displays the gas name, Provide remote mount sensor / transmitters for CO, with an HVAC electrochemical sensor for
concentration and alarm status. The PDC features LED alarm indicators, CO with a detection range of 0 - 200 ppm. The sensor / transmitter for CO shall be housed
audible alarm with silence button, and RoHS compliant circuit boards. in a wall mount, rugged, break resistant, PVC junction box with a secured, hinged door.
An optional watertight Polycarbonate enclosure shall be available. The remote mount CO
sensor / transmitter shall operate on power supplied by the control panel, and shall provide
Use with any CETCI analog transmitters, AST or ATW series, or digital
a digital output signal to the control panel. Install the CO sensor at approximately 4 - 6 ft
transmitters, DST series. Each PDC is pre-programmed at the factory, and is from the floor. Model DST-ECO. Supply one sensor / transmitter for every 5,000 - 7,000 ft2
completely field adjustable using a boardmounted push button keypad. of exposure area. The electrochemical CO sensor shall be capable of meeting government
Occupational Health and Safety measurement standards for workplace exposure to toxic
gases & vapours.
KEY FEATURES
» Up to 8 analog transmitters or up to 128 digital transmitters Provide remote mount sensor / transmitters for NO2 with an electrochemical sensor with
a range of 0 - 10 ppm. The sensor / transmitter for NO2 shall be housed in a wall mount,
» RS485 communication with digital transmitters rugged, break resistant, PVC junction box with a secured, hinged door. An optional
» RoHS compliant circuit boards watertight Polycarbonate enclosure shall be available. The remote mount NO2 sensor /
» Relay output modules transmitter shall operate on power supplied by the control panel, and shall provide a digital
» Scrolling, two line LCD display output signal to the control panel. Install the NO2 sensor at
approximately 4 - 6 ft from the floor. Model DST-END. Supply one sensor / transmitter for
» LED alarm indicators
every 5,000 - 7,000 ft2 of exposure area. The NO2 gas sensor shall be capable of meeting
» Completely field programmable government Occupational Health and Safety measurement standards for workplace
» Low, mid and high alarm setpoints exposure to toxic gases and vapours.
» Audible alarm with silence button
» Four wire daisychain wiring System operation shall be as follows: Upon detection of 25 ppm CO in air or 0.7 ppm NO2,
the system shall illuminate the Low alarm LED, the Low alarm relays (exhaust fans) will be
» Eight onboard SPDT relays activated [Link] system shall keep the fans running for a minimum of 10 minutes
» Optional BACnet® output module to avoid cycling. Upon detection of 50 ppm CO in air or 1.0 ppm NO2, the system shall
» CSA & UL certified illuminate the Mid alarm LED and the Mid alarm relays will be activated, (Mid alarm only
available with LCD display). The system shall keep the Mid relays active for a minimum of 10
minutes. Upon detection of 100 ppm CO in air or 1.5 ppm NO2, the system shall illuminate
APPLICATIOnS the High alarm LED, the High alarm relays and audible alarm will be activated. The system
shall keep the High relays active for a minimum of 10 minutes. Audible alarm can be
» Parking Garages silenced from the front panel push button.
» Repair Shops
» Arenas The contractor shall provide all wiring, conduit and interconnection required for a successful
» Pools installation.
» Food Processing Plants More specification samples are available at [Link].
» ... and many more
32 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Controllers - GAS DETECTION DATASHEET
MECHAnICAL
Enclosure Lockable, powder painted 18 gauge steel
Weight 4.3 kg (9.4 lbs)
12.3” x 12.3” x 4.2”
Size
(311 mm x 311 mm x 106 mm) PRODUCT CODES
AnALOG InPUT MODEL
ELECTRICAL
Up to 2 inputs PDC-A02
Power Requirement 90 - 240 VAC, 47 - 63 Hz
Up to 8 inputs PDC-A08
DATASHEE T
Current Draw 500 mA (controller only)
Outputs 4 - 20 mA signals
DIGITAL InPUT MODEL
Relay 8 dry SPDT contact, 5 amps @ 240 V each
Up to 8 inputs PDC-D08
Analog 3 wire shielded
Up to 16 inputs, 1 only CNB-2 PDC-D16
Digital daisychain only, shielded
Wiring Up to 24 inputs, 1 only CNB-2 & 1 only RPS-24 V PDC-D24
2 wire 14 gauge stranded power
2 wire 18 gauge twisted pair network Up to 32 inputs, 2 only CNB-2 & 1 only RPS-24 V PDC-D32
Fuse Automatic resetting thermal Up to 64 inputs, 4 only CNB-2 & 2 only RPS-24 V PDC-D64
Up to 96 inputs, 5 only CNB-2 & 3 only RPS-24 V PDC-D96
EnVIROnMEnTAL (sensor dependant) Up to 128 inputs, 6 only CNB-2 & 4 only RPS-24 V PDC-D128
Operating Temperature 0°C to 40°C (32°F to 100°F)
Humidity 10 - 95% RH non-condensing OPTIOnS (to be added to the end of the product code)
Industrial horn, 103 dB, remote H
CERTIFICATIOn BACnet® output module BAC
CSA Certified Strobe light, 4” diameter, remote L
UL Certified
ACCESSORIES
Relay module, 8 relays each, remote RRM-8
Analog output module, 8 4 - 20 mA outputs each RAO-8
Power supply, 24 V, remote RPS-24V
CAN network bridge CNB-2
Strobe & horn combo, remote RSH-24
Annunciator, remote RAP-128
Metal protective guard, large, 16 gauge, galvanized
SCS-8000-SPG
metal guards for controllers
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 33
Controllers - GAS DETECTION DATASHEET
APPLICATIOnS
» Parking Garages
» Repair Shops
» Arenas
» Pools
» Food Processing Plants
» ... and many more
34 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Controllers - GAS DETECTION DATASHEET
MECHAnICAL
Enclosure Watertight fiberglass reinforced polyester
Weight 4.5 kg (9.8 lbs)
Size 14” x 12” x 8” (356 mm x 305 mm x 203 mm)
PRODUCT CODES
ELECTRICAL AnALOG InPUT MODEL
Power Requirement 90 - 240 VAC, 47 - 63 Hz Up to 2 inputs PDC-A02-W
Current Draw 500 mA (controller only) Up to 8 inputs PDC-A08-W
DATASHEE T
Outputs 4 - 20 mA signals
Relay 8 dry SPDT contact, 5 amps @ 240 V each DIGITAL InPUT MODEL
Analog 3 wire shielded Up to 8 inputs PDC-D08-W
Digital daisychain only, shielded Up to 16 inputs, 1 only CNB-2 PDC-D16-W
Wiring
2 wire 14 gauge stranded power
Up to 24 inputs, 1 only CNB-2 & 1 only RPS-24 V PDC-D24-W
2 wire 18 gauge twisted pair network
Up to 32 inputs, 2 only CNB-2 & 1 only RPS-24 V PDC-D32-W
Fuse Automatic resetting thermal
Up to 64 inputs, 4 only CNB-2 & 2 only RPS-24 V PDC-D64-W
Up to 96 inputs, 5 only CNB-2 & 3 only RPS-24 V PDC-D96-W
EnVIROnMEnTAL (sensor dependant)
Up to 128 inputs, 6 only CNB-2 & 4 only RPS-24 V PDC-D128-W
Operating Temperature 0°C to 40°C (32°F to 100°F)
Humidity 10 - 95% RH non-condensing
OPTIOnS (to be added to the end of the product code)
Industrial horn, 103 dB, remote H
CERTIFICATIOn
BACnet® output module BAC
CSA Certified
Strobe light, 4” diameter, remote L
UL Certified
ACCESSORIES
Relay module, 8 relays each, remote RRM-8
Analog output module, 8 4 - 20 mA outputs each RAO-8
Power supply, 24 V, remote RPS-24V
CAN network bridge CNB-2
Strobe & horn combo, remote RSH-24
Annunciator, remote RAP-128
Metal protective guard, large, 16 gauge, galvanized
SCS-8000-SPG
metal guards for controllers
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 35
Self Contained - GAS DETECTION DATASHEET
GEM-II Multi-Purpose Gas Detector
TECHnICAL DRAWInG
door, Lexan label, and optional 4-digit display. range of 0 - 10 ppm NO2 in air. Area of monitoring coverage is up to 5,000 -
7,000 ft2 per sensor.
KEY FEATURES The monitor shall provide an LED indicating light for power, low alarm, high
alarm, and fault condition plus channel indication LEDs, one audible alarm
» Single or dual channel operation with silence push-button and two SPDT dry contact alarm relays, each rated 5
» Network multiple units A at 240 VAC. The system must be accurate enough to measure to government
» Integral or remote sensors workplace hazardous gas exposure standards. The system shall also provide
» Integral plug and play “smart” sensors field adjustable time delays for “delays on make” and “delays on break” for
» 4 - 20 mA linear output signal each sensor to allow custom configuration of fan control by the system relays,
» Three conduit entry ports if desired.
» Thermal resetting fuse
» LED light indicators The controller shall provide a circuit test button to allow the user to confirm
» Two 5-amp SPDT relays system operation and exhaust fan control from the panel. The controller shall
» RoHS compliant circuit boards also provide a push-button to allow the user to override the system control and
operate exhaust fans continuously for 15-minute segments to evacuate air from
» Economical
specific parts of the parking garage. Installation height for the gas detection
» CSA, UL & C-Tick certified controller with integral CO & NO2 sensors is 4 - 6 ft from the floor.
The contractor shall provide all wiring, conduit and interconnection required
for a successful installation. System should be tested and commissioned after
installation, with a report provided after the site visit.
36 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Self Contained - GAS DETECTION DATASHEET
GEM-II Multi-Purpose Gas Detector
TECHnICAL SPECIFICATIOnS PRODUCT CODES
GAS TYPE SInGLE CHAnnEL MODEL
Carbon Monoxide (CO) ECO Integral sensor, carbon monoxide (CO) GEM-AECO
Combustibles (solid state) SCB Integral sensor, nitrogen dioxide (NO2) GEM-AEND
Methane (CH4) SCB Integral sensor, nitric oxide (NO) GEM-AENO
Nitrogen Dioxide (NO2) END Integral sensor, sulphur dioxide (SO2) GEM-AESO
Nitric Oxide (NO) ENO Integral sensor, oxygen (O2) GEM-AEO2
Oxygen (O2) EO2 Remote sensor GEM-B
Propane (C3H8) SCB Remote sensor, combustible gases (solid state) GEM-BSCB
Refrigerants (R12, R22, R134A, R401A, R402A, Remote sensor, methane (CH4) GEM-BSCB
SR2 Remote sensor, propane (C3H8) GEM-BSCB
R404A, R407C, R410A, R422A, R422D, R438A, R507)
Sulphur Dioxide (SO2) ESO Remote sensor, refrigerants (solid state) GEM-BSR2
TVOCs (solid state) SOS Remote sensor, TVOCs (solid state) GEM-BSOS
DATASHEE T
Power Requirement 15 - 30 VDC or 12 - 28 VAC Integral carbon monoxide (CO),
GEM-DECO-END
Current Draw Approximately 125 mA remote nitrogen dioxide (NO2)
Outputs Linear 4 - 20 mA (single) Integral carbon monoxide (CO),
GEM-DECO-ENO
VDC three-conductor shielded remote nitric oxide (NO)
Wiring
VAC four-conductor shielded Integral & remote sensors, oxygen (O2) GEM-DEO2-EO2
Fuse Automatic resetting thermal Integral & remote sensors, nitrogen dioxide (NO2) GEM-DEND-END
Integral & remote sensors, nitric oxide (NO) GEM-DENO-ENO
EnVIROnMEnTAL (sensor dependant) Integral, carbon monoxide (CO) &
GEM-EECO-END
nitrogen dioxide (NO2)
Operating
-20°C to 50°C (-5°F to 120°F) Integral, carbon monoxide (CO) & nitric oxide (NO) GEM-EECO-ENO
Temperature
Humidity 15 - 90% RH non-condensing Integral, carbon monoxide (CO) & oxygen (O2) GEM-EECO-EO2
Integral, carbon monoxide (CO) &
GEM-EECO-ESO
sulphur dioxide (SO2)
CERTIFICATIOn
Integral, nitrogen dioxide (NO2) &
CSA Certified GEM-EEND-ESO
sulphur dioxide (SO2)
UL Certified
OPTIOnS (to be added to the end of the product code)
LED digital display N
120 VAC powered version J
Enclosed external transformer, 120 - 22 VAC TIB-2250
ACCESSORIES
Calibration kit, 15 L or 17 L cylinder,
CET-8000-CK1
0.5 LPM flow regulator
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinder,
CET-7150-CK1
0.5 LPM flow regulator
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 37
Self Contained - GAS DETECTION DATASHEET
The contractor shall provide all wiring, conduit and interconnection required
for a successful installation. System should be tested and commissioned after
installation, with a report provided after the site visit.
38 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Self Contained - GAS DETECTION DATASHEET
DATASHEE T
Power Requirement 15 - 30 VDC or 12 - 28 VAC Integral & remote sensors, carbon monoxide (CO) GEM-DECO-ECO-W
Current Draw Approximately 125 mA Integral carbon monoxide (CO),
GEM-DECO-END-W
Outputs Linear 4 - 20 mA (single) remote nitrogen dioxide (NO2)
VDC three-conductor shielded Integral carbon monoxide (CO),
Wiring GEM-DECO-ENO-W
VAC four-conductor shielded remote nitric oxide (NO)
Fuse Automatic resetting thermal Integral & remote sensors, oxygen (O2) GEM-DEO2-EO2-W
Integral & remote sensors, nitrogen dioxide (NO2) GEM-DEND-END-W
EnVIROnMEnTAL (sensor dependant) Integral & remote sensors, nitric oxide (NO) GEM-DENO-ENO-W
Operating Integral, carbon monoxide (CO) &
-20°C to 50°C (-5°F to 120°F) GEM-EECO-END-W
Temperature nitrogen dioxide (NO2)
Humidity 15 - 90% RH non-condensing Integral, carbon monoxide (CO) &
GEM-EECO-ENO-W
nitric oxide (NO)
Integral, carbon monoxide (CO) & oxygen (O2) GEM-EECO-EO2-W
CERTIFICATIOn
Integral, carbon monoxide (CO) &
CSA Certified GEM-EECO-ESO-W
sulphur dioxide (SO2)
UL Certified Integral, nitrogen dioxide (NO2) &
GEM-EEND-ESO-W
sulphur dioxide (SO2)
ACCESSORIES
Calibration kit, 15 L or 17 L cylinders,
CET-8000-CK1
0.5 LPM flow regulator
Calibration kit, 34 L, 58 L, 75 L, or 103 L
CET-7150-CK1
cylinders, 0.5 LPM flow regulator
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 39
Transmitters - GAS DETECTION DATASHEET
AST-I Industrial Infrared Transmitter
TECHnICAL DRAWInG
AST-ICD, AST-IHC & AST-INI are analog transmitters with high quality,
industrial grade, miniature infrared sensors. They are supplied, as a
standard in a water / dust tight, corrosion resistant polycarbonate
enclosure.
These instruments use high quality, long life, dual beam [Link]
DATASHEE T
KEY FEATURES
» Dual temperature compensated pyroelectric infrared detectors
» Low power consumption
» RoHS compliant circuit boards
» Fast response
» Water / dust tight / corrosion resistant polycarbonate enclosure
» Linear analog (4 - 20 mA) output
» Target gases include CO2, Hydrocarbons (including Methane),
Nitrous Oxide
» Measurement ranges from 0 - 1,000 ppm up to 0 - 100% volume
(sensor & gas dependent)
APPLICATIOnS
» Commercial Buildings
» Institutional Buildings
» Waste Water Treatment Plants
» Oil & Gas Plants
» Manufacturing Plants
» ... and many more
44 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
DATASHEE T
0 - 100% volume CO2
Industrial carbon dioxide (CO2), watertight housing,
MECHAnICAL AST-ICD-DW
0 - 100% volume CO2
Enclosure Water / dust tight polycarbonate
Weight 255 g (9 oz) AST-IHC InDUSTRIAL HYDROCARBOn GASES (CH4)
Size 4.9” x 4.9” x 2.9” (125 mm x 125 mm x 74 mm) Industrial hydrocarbon gases, watertight housing,
AST-IHC-BW
0 - 100% LEL CH4
ELECTRICAL Industrial hydrocarbon gases, watertight housing,
AST-IHC-CW
24 VDC nominal (12 - 30 VDC) 0 - 100% volume CH4
Power Requirement
(polarity protected) 5 W maximum
Current Draw 70 - 100 mA AST-InI InDUSTRIAL nITRIOUS OxIDE (n2O)
Linear 4 - 20 mA analog Industrial nitrious oxide (N2O), watertight housing,
Outputs AST-INI-EW
(10 bit resolution with current limit) 0 - 1,000 ppm N2O
500 mA anti-surge in-line fuse
Fuse
for supplied power
ACCESSORIES
Calibration kit, 15 L or 17 L cylinders,
EnVIROnMEnTAL (sensor dependant) CET-8000-CK1
0.5 LPM flow regulator
Operating Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders,
-20°C to 50°C (-4°F to 122°F) CET-7150-CK1
Temperature 0.5 LPM flow regulator
Humidity 0 - 95% RH non-condensing Metal protective guard, small, 16 gauge,
SCS-8000-RSG
galvanized metal guards for transmitters
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 45
Transmitters - GAS DETECTION DATASHEET
AST-IS Standard CO2 Transmitter
TECHnICAL DRAWInG
AST-IS transmitters convert the raw signal from a sensor into a useful
output that can be sent to a controller or building automation system.
DATASHEE T
KEY FEATURES
» 4 - 20 mA or 0 - 10 VDC linear output signal
» Operating power 24 VDC or 24 VAC nominal
» Lifetime calibration
» 0 - 2,000 ppm standard range
» Optional relay, LCD digital display & duct mount kit
» RoHS compliant circuit boards
» CE certified
APPLICATIOnS
» Residential Buildings
» Commercial Buildings
» Greenhouses
» Schools / Educational Institutions
» Offices
» ... and many more
48 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
AST-IS Standard CO2 Transmitter
WIRInG
DATASHEE T
SEnSOR Carbon dioxide (CO2), wall mount
AST-IS14
Sampling Method Non-dispersive infrared with LCD digital display & audible alarm
Monitoring Method Diffusion Carbon dioxide (CO2), wall mount VAV
AST-IS15
with hidden LCD digital display
Range 0 - 2,000 ppm
Carbon dioxide (CO2), wall mount VAV
Accuracy ± 30 ppm, ± 3% of reading AST-IS16
with LCD digital display
CERTIFICATIOn
CE Certified
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 49
Transmitters - GAS DETECTION DATASHEET
AST-IS Industrial CO2 Transmitter
TECHnICAL DRAWInG
Duct mount
with optional LED display
AST-IS transmitters convert the raw signal from a sensor into a useful
SAMPLE EnGInEERInG SPECIFICATIOnS
output that can be sent to a controller or building automation system. Coming soon...
DATASHEE T
KEY FEATURES
» 4 - 20 mA or 0 - 10 VDC linear output signal
» Operating power 24 VDC or 24 VAC nominal
» Lifetime calibration
» 0 - 2,000 ppm standard range
» Optional relay, LCD digital display & duct mount kit
» RoHS compliant circuit boards
» CE certified
APPLICATIOnS
» Residential Buildings
» Commercial Buildings
» Greenhouses
» Schools / Educational Institutions
» Offices
» ... and many more
50 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
AST-IS Industrial CO2 Transmitter
WIRInG
DATASHEE T
Outputs Linear 4 - 20 mA or 0 - 10 VDC signal Carbon dioxide (CO2), duct mount AST-IS17
with LCD digital display
SEnSOR Carbon dioxide (CO2), wall mount with IP54 AST-IS18
Sampling Method Non-dispersive infrared industrial enclosure, 0 - 4% volume
Monitoring Method Diffusion
Range 0 - 2,000 ppm
Accuracy ± 30 ppm, ± 3% of reading
CERTIFICATIOn
CE Certified
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 51
Transmitters - GAS DETECTION DATASHEET
communication bus, and feature a thermal resetting fuse, an LED temperature compensation and an automatic resetting thermal fuse for
indicator for power, alarm and fault, RoHS compliant circuit boards, and fault protection.
an internal “on line” LED.
The transmitter circuit shall be housed in a wall mount, rugged, break
Automated calibration and other maintenance procedures are simple and resistant, corrosion resistant, PVC junction box with a secured, hinged
are easily performed in the field. door. The PVC junction box shall have conduit entry ports on the top,
bottom, right side and rear. The circuit shall operate from 24 VDC input
voltage supplied from the controller. Wiring shall be 2 conductors
for low voltage power, and a two wire shielded twisted pair for the
KEY FEATURES communication bus. Wiring shall be shielded or in conduit.
» RS485 digital output signal
» Wide variety of sensors for all applications An optional watertight Polycarbonate enclosure shall be available.
» RoHS compliant circuit boards
» Configured for 4 wire multi-drop wiring Provide digital signal readings to the controller to allow accurate settings
» Thermal resetting fuse for fan control at 25 ppm CO or 10% LEL Propane and a secondary alarm
» LED indicator for power & alarm status condition at 100 ppm CO or 20% LEL Propane.
» Power requirement 24 VDC nominal
» Simple calibration procedure The contractor shall provide all required wiring, conduit and
interconnection required for a successful installation.
56 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
MECHAnICAL
Enclosure Polycarbonate
Weight 255 g (9 oz)
DATASHEE T
Size 4.4” x 6.5” x 2.5” (113 mm x 165 mm x 65 mm)
PRODUCT CODES
ELECTRICAL Ammonia (NH3), 0 - 500 ppm DST-EAM
Power Requirement 24 VDC supplied by PDC controller Carbon monoxide (CO), 0 - 200 ppm DST-ECO
Current Draw 80 - 120 mA Combustible gases (solid state), 0 - 50% LEL DST-SCB
Scaled linear digital signal Chlorine (Cl2), 0 - 5 ppm DST-ECL
Outputs
RS485 communication bus Ethylene oxide (ETO), 0 - 20 ppm DST-EET
Daisy chain configuration only. Hydrogen (H2), 0 - 2,000 ppm DST-EH2
Power: 14 gauge stranded, 2-conductor Hydrogen sulphide (H2S), 0 - 50 ppm DST-EHS
Wiring Signal: shielded twisted pair, 18 gauge,
Methane (CH4), 0 - 50% LEL DST-SCB
low capacitance. Network bridge every
1,000 feet or less. Nitrogen dioxide (NO2), 0 - 10 ppm DST-END
Fuse Automatic resetting thermal Nitric oxide (NO), 0 - 100 ppm DST-ENO
Oxygen (O2), 0 - 25% volume DST-OO2
EnVIROnMEnTAL (sensor dependant) Ozone (O3), 0 - 2 ppm DST-EO3
Propane (C3H8), 0 - 50% LEL DST-SCB
Operating
-20°C to 40°C (-4°F to 104°F) Sulphur dioxide (SO2), 0 - 20 ppm DST-ESO
Temperature
Humidity 15 - 95% RH non-condensing
ACCESSORIES
Calibration kit, 15 L or 17 L cylinders,
CET-8000-CK1
0.5 LPM flow regulator
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders,
CET-7150-CK1
0.5 LPM flow regulator
Metal protective guard, small, 16 gauge,
SCS-8000-RSG
galvanized metal guards for transmitters
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 57
Transmitters - GAS DETECTION DATASHEET
applications. automatic resetting thermal fuse for fault protection. The transmitters
shall be installed 4 - 6 ft from the floor (breathing zone) and each unit
DST transmitters output scaled linear signals on an RS485 shall be capable of monitoring an area of approximately 5,000 - 7,500 ft2.
communication bus, and feature a thermal resetting fuse, an LED
indicator for power, alarm and fault, RoHS compliant circuit boards, and The transmitter circuit shall be housed in a wall mount, rugged, break
an internal “on line” LED. resistant, corrosion resistant, PVC junction box with a secured, hinged
door. The PVC junction box shall have conduit entry ports on the top,
Automated calibration and other maintenance procedures are simple and bottom, right side and rear. The circuit shall operate from 24 VDC input
are easily performed in the field. voltage supplied from the controller. Wiring shall be 2 conductors
for low voltage power, and a two wire shielded twisted pair for the
communication bus. Wiring shall be shielded or in conduit.
KEY FEATURES
An optional watertight Polycarbonate enclosure shall be available.
» RS485 digital output signal
System operation shall be as follows: Upon detection of 0.7 ppm NO2 or
» Wide variety of sensors for all applications
25 ppm CO, the controller shall activate exhaust fans. Upon detection
» RoHS compliant circuit boards
of 1.5 ppm NO2 or 100 ppm CO, the controller shall activate audible and
» Configured for 4 wire multi-drop wiring
visual alarms.
» Thermal resetting fuse
» LED indicator for power & alarm status
The contractor shall provide all required wiring, conduit and
» Power requirement 24 VDC nominal
interconnection required for a successful installation.
» Simple calibration procedure
More specification samples are available at [Link]-
[Link].
APPLICATIOnS
» Parking Garages
» Repair Shops
» Ice Cleaning Machine Rooms
» Pools
» Manufacturing plants
» ... and many more
58 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
MECHAnICAL
PRODUCT CODES
Enclosure Water / dust tight polycarbonate
Ammonia (NH3), 0 - 500 ppm DST-EAM-W
Weight 340 g (12 oz)
DATASHEE T
Combustible gases (solid state), 0 - 50% LEL DST-SCB-W
Size 5.1” x 5.1” x 3.1” (129 mm x 129 mm x 77 mm)
Carbon monoxide (CO), 0 - 200 ppm DST-ECO-W
Chlorine (Cl2), 0 - 5 ppm DST-ECL-W
ELECTRICAL
Ethylene oxide (ETO), 0 - 20 ppm DST-EET-W
Power Requirement 24 VDC supplied by PDC controller
Hydrogen (H2), 0 - 2,000 ppm DST-EH2-W
Current Draw 80 - 120 mA
Hydrogen sulphide (H2S), 0 - 50 ppm DST-EHS-W
Scaled linear digital signal
Outputs Methane (CH4), 0 - 50% LEL DST-SCB-W
RS485 communication bus
Daisy chain configuration only. Nitrogen dioxide (NO2), 0 - 10 ppm DST-END-W
Power: 14 gauge stranded, 2-conductor Nitric oxide (NO), 0 - 100 ppm DST-ENO-W
Wiring Signal: shielded twisted pair, 18 gauge, Oxygen (O2), 0 - 25% volume DST-OO2-W
low capacitance. Network bridge every
Ozone (O3), 0 - 2 ppm DST-EO3-W
1,000 feet or less.
Propane (C3H8), 0 - 50% LEL DST-SCB-W
Fuse Automatic resetting thermal
Sulphur dioxide (SO2), 0 - 20 ppm DST-ESO-W
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 59
Transmitters - GAS DETECTION DATASHEET
LPT transmitter features a two-wire loop, three-wire VDC or four-wire SAMPLE EnGInEERInG SPECIFICATIOnS
VAC power; making installation a cinch. LPT transmitter also features a
4 - 20 mA linear output signal, automatic thermal resetting fuse, RoHS Coming soon...
DATASHEE T
Includes new sensor CEF (Calibration Extending Firmware) that takes into
account the aging of the sensors so that less frequent calibrations are
acceptable in non-critical applications.
KEY FEATURES
» Linear 4 - 20 mA output signal
» Standard water / dust tight enclosure
» Single sensor: carbon monoxide (CO) or nitrogen dioxide (NO2)
» RoHS compliant circuit boards
» 2-wire loop, 3-wire VDC or 4-wire VAC power
» Easy maintenance
» Economical
» Includes sensor CEF (calibration extending firmware)
» Auto resetting fuse
» Automated calibration procedure
APPLICATIOnS
» Parking Garages
» Repair Shops
» Ice Cleaning Machine Rooms
» Manufacturing plants
» ... and many more
60 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
MECHAnICAL
Enclosure ABS / Polycarbonate
Weight tbd
Size 5.0” x 4.0” x 1.9” (127 mm x 102 mm x 48 mm)
ELECTRICAL
Power Requirement
2-wire mode 16 - 30 VDC
3-wire mode 16 - 30 VDC
4-wire mode 12 - 30 VAC or 16 - 30 VDC
Current Draw Maximum 25 mA
Linear 4 - 20 mA
Maximum 216 Ω load (wiring plus termination
Outputs resistor) at 16 VDC
Maximum 316 Ω load (wiring plus termination
resistor) at 12 VAC
VDC two or three-conductor shielded;
Wiring
DATASHEE T
VAC four-conductor shielded
Fuse Automatic resetting thermal
CERTIFICATIOn
CE Pending
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 61
Transmitters - GAS DETECTION DATASHEET
PET BACnet® Transmitter
TECHnICAL DRAWInG
Dual sensor
with optional LED display
PET BACnet® digital transmitter is a “Parkade Emissions Transmitter” SAMPLE EnGInEERInG SPECIFICATIOnS
that communicates via BACnet® protocol MS / TP. It is available with one
or two electrochemical sensors or solid-state sensors and temperature Coming soon...
sensor, enclosed in a general purpose ABS enclosure.
DATASHEE T
Featuring thermal resetting fuse, tri-color LED indicator for power and
alarm, and an optional 4-digit LED display.
Includes new sensor CEF (Calibration Extending Firmware) that takes into
account the aging of the sensors so that less frequent calibrations are
acceptable in non-critical applications.
KEY FEATURES
» MS / TP BACnet® communication
» RoHS compliant circuit boards
» Thermal resetting fuse
» Tri-color LED light indicator
» Economical
» Easy maintenance
» Single or dual gas sensor
» Includes temperature sensor
» BTL certified
APPLICATIOnS
» Parking Garages
» Repair Shops
» Commercial HVAC Buildings
» Light Industrial Plants
» Laboratories
» Schools / Educational Institutions
» ... and many more
62 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Transmitters - GAS DETECTION DATASHEET
PET BACnet® Transmitter
TECHnICAL SPECIFICATIOnS PRODUCT CODES
GAS TYPE SInGLE CHAnnEL MODEL
Ammonia (NH3) EAM Ammonia (NH3), 0 - 500 ppm PET-EAM
Carbon Monoxide (CO) ECO Carbon monoxide (CO), 0 - 200 ppm PET-ECO
Combustible Gases (solid state) SCB Combustible gases (solid state), 0 - 50% LEL PET-SCB
Ethylene (C2H4) EC4 Ethylene (C2H4), 0 - 2,000 ppm PET-EC4
Formaldehyde (CH2O) EFO Formaldehyde (CH2O), 0 - 10 ppm PET-EFO
Hydrogen (H2) EH2 Hydrogen (H2), 0 - 2,000 ppm PET-EH2
Methane (CH4) SCB Methane (CH4), 0 - 50% LEL PET-SCB
Nitrogen Dioxide (NO2) END Nitrogen dioxide (NO2), 0 - 10 ppm PET-END
Nitric Oxide (NO) ENO Nitric oxide (NO), 0 - 100 ppm PET-ENO
Oxygen (O2) OO2 Oxygen (O2), 0 - 25% volume PET-OO2
Propane (C3H8) SCB Propane (C3H8), 0 - 50% LEL PET-SCB
Refrigerants (R12, R22, R134A, R401A, R402A, Refrigerants (R12, R22, R134A, R401A, R402A, R404A,
SR2
R404A, R407C, R410A, R422A, R422D, R438A, R507) R407C, R410A, R422A, R422D, R438A, R507), PET-SR2
Sulphur Dioxide (SO2) ESO 0 - 2,000 ppm
TVOCs (solid state) SOS Sulphur Dioxide (SO2), 0 - 20 ppm PET-ESO
TVOCs (solid state), 0 - 500 ppm PET-SOS
MECHAnICAL
Enclosure General Purpose ABS DUAL CHAnnEL MODEL
DATASHEE T
(Choose an electrochemical sensor above & add second electrochemical sensor below)
Weight 284 g (10 oz)
Size 5.0” x 3.5” x 1.5” (127 mm x 89 mm x 38 mm) Nitrogen dioxide (NO2), 0 - 10 ppm END
Nitric oxide (NO), 0 - 100 ppm ENO
ELECTRICAL Oxygen (O2), 0 - 25% volume OO2
Power Requirement 24 VDC Sulphur Dioxide (SO2), 0 - 20 ppm ESO
Current Draw 30 mA; 90 mA (with display)
BACnet® MS / TP up to 76,800 bps OPTIOnS (to be added to the end of the product code)
Outputs
MAC address 0-127 DIP switch settable LED digital display N
4-conductor shielded network wiring Remote housing (solid state sensor only) R
Wiring
(daisy-chained) 4 - 20 mA analog input (solid state sensor only) A
Fuse Automatic resetting thermal Water / dust tight enclosure W
Splash guard (for watertight enclosure only) S
EnVIROnMEnTAL (sensor dependant)
Operating Temperature Sensor dependant ACCESSORIES
Humidity Sensor dependant Calibration kit, 15 L or 17 L cylinders,
CET-8000-CK1
0.5 LPM flow regulator
CERTIFICATIOn Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders,
CET-7150-CK1
0.5 LPM flow regulator
BTL Certified
Metal protective guard, small, 16 gauge,
CE & C-Tick Pending SCS-8000-RSG
galvanized metal guards for transmitters
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 63
Accessories - GAS DETECTION DATASHEET
KEY FEATURES
» 16 gauge, clear anodized metal protective guards PRODUCT CODES
» Large size for self-contained systems and controllers
» Smaller size for analog & digital transmitters Small, 16 gauge galvanized metal guards
SCS-8000-RSG
» Easy installation for transmitters
APPLICATIOnS
» Residential Buildings
» Commercial Buildings
» Hospitals
» Laboratories
» Research Facilities
» Parking Garages
» ... and many more
64 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Accessories - GAS DETECTION DATASHEET
DATASHEE T
in the front to allow gas and air to flow through to the sensor. With only
four slotted mounting holes, installation and removal for gas detector Weight 1.7 kg (3.8 lbs)
servicing is easy.
10.0” x 9.5” x 4.8”
Size
(254 mm x 241 mm x 121 mm)
KEY FEATURES
» 16 gauge, clear anodized metal protective guards PRODUCT CODES
» Large size for self-contained systems and controllers Large, 16 gauge galvanized metal guards
» Smaller size for analog & digital transmitters SCS-8000-RSG
for controllers
» Easy installation
APPLICATIOnS
» Residential Buildings
» Commercial Buildings
» Hospitals
» Laboratories
» Research Facilities
» Parking Garages
» ... and many more
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 65
Portable IAQ Instruments - GAS DETECTION DATASHEET
YESAIR 8-Channel IAQ Monitor
APPLICATIOnS
» Residential Buildings
» Commercial Buildings
» Hospitals
» Laboratories
» Research Facilities
» Parking Garages
» ... and many more
TECHnICAL DRAWInG
YESAIR offers more features, flexibility and functionality than any other
IAQ instrument on the market today with multi-channel operation,
more than 30 different plug and play sensors to select from, including
a particulate sensor, huge capacity data logging to SD flash card and
DATASHEE T
much more.
With a few simple mouse clicks, users can analyze and graph data using
the optional YES Viewer PC software and an SD card reader. Alternatively,
data could be downloaded through the instrument using a standard USB
connection.
KEY FEATURES
» 8 sensor capacity
» > 30 plug & play sensors available to choose from, including
electrochemical, catalytic, infrared & PID
» Multi-function, easy to use menu
» Light weight, contoured & comfortable handheld device
» LCD displays all sensors
» Sampling with internal sample draw pump or by diffusion
» High capacity data logging with built-in SD flash card
» Data logging software available
» RoHS compliant circuit boards
» CE certified
66 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Portable IAQ Instruments - GAS DETECTION DATASHEET
ELECTRICAL
OPTIOnS
Standard: Rechargable 3.6 V NiMH battery
pack (8 hours continuous operation time Ammonia (NH3) electrochemical, 0 - 50 ppm PNP-H
Power c/w plug-in battery charger / wall adapter Arsine (AsH3) electrochemical, 0 - 2 ppm PNP-R
(100 - 240 V, 50 - 60 Hz) Carbon dioxide (CO2) infrared, 0 - 5,000 ppm PNP-A+
Optional: Alkaline AA batteries x 3
Carbon dioxide (CO2) infrared, 0 - 10,000 ppm PNP-A1
Standard: Internal, automatic sample pump
Carbon dioxide (CO2) infrared, 0 - 20% volume PNP-A2
Sampling for “active” sampling of target environment
Optional: Diffusion for quick, direct reading. Carbon dioxide (CO2) infrared, 0 - 5% volume PNP-B
> 1 million data points data logging to Carbon dioxide (CO2) infrared, 0 - 100% volume PNP-B1
Memory
SD flash card (optional) Carbon monoxide (CO) electrochemical, 0 - 50 ppm PNP-C
Calibration Automated through keypad Carbon monoxide (CO) electrochemical, 0 - 50 ppm
PNP-C1
(H2 compensated for use in H2 background)
12 bit, multi-channel, user configurable
with removable flash card 2 GB. Chlorine (Cl2) electrochemical, 0 - 5 ppm PNP-I
Information Recording YES Logger package option includes 2 GB SD Chlorine dioxide (ClO2), electrochemical, 0 - 1 ppm PNP-J
flash card, USB cable, YES Viewer software, Combustibles (catalytic), 0 - 100% LEL PNP-X
DATASHEE T
and SD flash card reader.
Ethylene (C2H4), 0 - 500 ppm PNP-E1
Miniature USB port for changing settings
Ethylene oxide (C2H4O), 0 - 20 ppm PNP-E2
and configuring logging functions and
Communication Fluorine (F2) electrochemical, 0 - 2 ppm PNP-S
auxiliary port for using additional sensors
(i.e. YESDUST) Formaldehyde (CH2O) electrochemical, 0 - 10 ppm PNP-Q
Internal 80 Db @ 4’. One set point Hydrogen (H2) electrochemical, 0 - 1,000 ppm PNP-K
Audible adjustment. Audible can be switched off Hydrogen chloride (HCl) electrochemical, 0 - 30 ppm PNP-M
through menu. Hydrogen cyanide (HCN) electrochemical, 0 - 100 ppm PNP-N
Hydrogen fluoride (HF) electrochemical, 0 - 10 ppm PNP-O
EnVIROnMEnTAL (sensor dependant) Hydrogen sulphide (H2S) electrochemical, 0 - 50 ppm PNP-L
Operating Temperature 5°C to 50°C (41°F to 122°F) Nitric oxide (NO) electrochemical, 0 - 100 ppm PNP-E
Humidity 0 - 99% RH non-condensing Nitrogen dioxide (NO2) electrochemical, 0 - 5 ppm PNP-D
Oxygen (O2) electrochemical, 0 - 25% volume PNP-F
CERTIFICATIOn Ozone (O3) electrochemical, 0 - 1 ppm PNP-G
CE standards for safety: Phosphine (PH3) electrochemical, 0 - 1 ppm PNP-V
I .S. EN61010-1:2001 (Ed.2) Silane (SiH4) electrochemical, 0 - 1 ppm PNP-W
CE Certified
CE standards for emissions: EN 50270:2006
Sulphur dioxide (SO2) electrochemical, 0 - 20 ppm PNP-P
CE standards for immunity: EN 50270:2006
TVOCs (PID), 0 - 300 ppm PNP-Y+
TVOCs (PID), 0 - 50 ppm PNP-Z+
External mounted nickel metal hydride pack YESAIR BATT OPTION
ACCESSORIES
Hard shell carrying case for YESAIR 6010.20
YES logger package, 2 GB flash card, USB cable, YES
YESAIR-LGRPKG
Viewer software, SD flash card reader
Handheld probe 10” with 30” of sample hose YES-HHPROBE-10
External lead acid battery, in carrying case w charger YES-AIR BATT EXT
YES Viewer information logging software CD YES-SFTWRE
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 67
Portable IAQ Instruments - GAS DETECTION DATASHEET
TECHnICAL DRAWInG
The large, backlit, multi-line scrolling LCD display indicates the sensor
types installed and measured values for each gas, battery status and
more. The system utilizes a long life rechargeable NiMH battery pack
providing more than 24-hours of run time, depending on sensor array
installed. The user can also set one alarm level for each gas to activate
the internal audible alarm. The system is housed in a rugged ABS
enclosure with swivel handle to act as a stand support or for carrying
the instrument.
KEY FEATURES
» 15 sensor capacity
» > 30 plug & play sensor choices
» Extensive, easy to use menu system
» Rugged ABS enclosure with swivel handle acts as stand support
» Internal sample pump with inline filter
» Large, backlit, multi-line, LCD display
» Data logging to SD flash card
» Menu control positive sampling
» RoHS compliant circuit boards
68 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Portable IAQ Instruments - GAS DETECTION DATASHEET
DATASHEE T
Humidity 0 - 99% RH non-condensing Fluorine (F2) electrochemical, 0 - 2 ppm PNP-S
Formaldehyde (CH2O) electrochemical, 0 - 10 ppm PNP-Q
CERTIFICATIOn Hydrogen (H2) electrochemical, 0 - 1,000 ppm PNP-K
CE Pending Hydrogen chloride (HCl) electrochemical, 0 - 30 ppm PNP-M
Hydrogen cyanide (HCN) electrochemical,
PNP-N
0 - 100 ppm
Hydrogen fluoride (HF) electrochemical, 0 - 10 ppm PNP-O
Hydrogen sulphide (H2S) electrochemical, 0 - 50 ppm PNP-L
Nitric oxide (NO) electrochemical, 0 - 100 ppm PNP-E
Nitrogen dioxide (NO2) electrochemical, 0 - 5 ppm PNP-D
Oxygen (O2) electrochemical, 0 - 25% volume PNP-F
Ozone (O3) electrochemical, 0 - 1 ppm PNP-G
Phosphine (PH3) electrochemical, 0 - 1 ppm PNP-V
Silane (SiH4) electrochemical, 0 - 1 ppm PNP-W
Sulphur dioxide (SO2) electrochemical, 0 - 20 ppm PNP-P
TVOCs (PID), 0 - 300 ppm PNP-Y+
TVOCs (PID), 0 - 50 ppm PNP-Z+
ACCESSORIES
Hard shell carrying case for YES Plus LGA 718
YES logger package, 2 GB flash card, USB cable,
YESAIR-LGRPKG
YES Viewer software, SD flash card reader
Handheld probe 10” with 30” of sample hose YES-HHPROBE-10
YES Viewer information logging software CD YES-SFTWRE
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 69
Industry Abbreviations & Product Acronyms
A Amperes COCl2 Phosgene
A/C Air Conditioning CSA Canadian Standards Associaation
ABS Acrylonitrile-Butadiene-Styrene DC Direct Current
amp Amperes DDC Direct Digital Controller
AsH3 Arsine DST Digital Signal Transmitter
ASHRAE American Society of Heating, EC Electrochemical
Refrigerating and Air EEPROM Electrically Erasable
Conditioning Engineers Programmable Read Only
AST Analog Signal Transmitter Memory
ATW Analog Two Wire EMC Electromagnetic Compatibility
avg Average En European Norm
BACnet® Building Automation and Control ETO Ethylene Oxide
Networking EU European Union
BMS Building Management System
F Fahrenheit
BST BACnet® Signal Transmitter
F2 Fluorine
BTL BACnet® Testing Laboratories
GB Gigabyte
BTU British Thermal Unit
GEM Gas Emissions Monitor
C Celsius
H2 Hydrogen
C2H4 Ethylene
H2S Hydrogen Sulphide
CAT Catalytic
HCHO Formaldehyde
CH2O Formaldehyde
HCn Hydrogen Cyanide
CH4 Methane
HE High Efficiency
CE Communaute Europeenne
HEPA High Efficiency Particulate Air
CEF Calibration Extending Firmware
HF Hydrogen Fluoride
CET or CETCI Critical Environment Technologies
HPU Heat Pump Unit
Canada Incorporated
HVAC Heating, Ventilation, and Air
cfm Cubic Feet Per Minute
Conditioning
Cl2 Chlorine
Hz Hertz
ClO2 Chlorine Dioxide IAQ Indoor Air Quality
cm Centimeters IP Ingress Protection
CO Carbon Monoxide IR Infrared
CO2 Carbon Dioxide kg Kilograms
72 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
lbs Pounds O2 Oxygen
LCD Liquid Crystal Display O3 Ozone
LED Light Emitting Diode PAC Programmable Analog Controller
LEL Lower Explosive Limit PDC Programmable Digital Controller
LGA Landfill Gas Analyzer PET Parkade Emissions Transmitter
LPM Liters Per Minute PH3 Phosphine
LPT Low Power Transmitter PID PhotoIonization Detector
m Meters PPM or ppm Parts Per Million
mA Milliampere psi Pounds Per Square Inch
MAC Mini Analog Controller PVC Polyvinyl Chloride
max Maximum QA Quality Assurance
MB Megabyte REL Recommended Exposure Limit
ME Medium Efficiency RH Relative Humidity
MERV Minimum Efficiency Reporting SCS Self Contained System
Value SiH4 Silane
min Minimum
SPDT Single Pole, Double Throw
mm Millimeters
SO2 Sulfur Dioxide
MS / TP Master-Slave / Token-Passing
SS Solid State
n2H4 Hydrazine
SSM Smart Sensor Module
n2O Nitrious Oxide
STEL Short Term Exposure Limit
nDIR Non-Dispersive Infrared
TLV Threshold Limit Value
nEC National Electric Code
TVOC Total Volative Organic Compound
nEMA National Electrical Manufacturers
TWA Time Weighted Average
Association
UL Underwriters Laboratories Inc.
nFPA National Fire Protection Agency
USB Universal Serial Bus
nH3 Ammonia
VAC Volts Alternating Current
niMH Nickel Metal Hydride
VDC Volts Direct Current
nIOSH National Institute of Occupational
Safety and Health VOC Volatile Organic Compound
nO2 Nitrogen Dioxide W Watts
nOx Nitrogen Oxides WWC Wired Wireless Controller
nTC Negative Temperature Coefficient ZEB Zero Energy Building
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 73
Glossary of Terms
% Volume LEL
The percentage of a gas in the total volume of air. An abbreviation for Lower Explosive Limit, which is the
minimum concentration of each gas in air that must be present
Breathing Zone for combustion or explosion to occur.
The breathing zone refers to the area 4 - 6 feet from the floor,
where most human breathing takes place. This is a good % LEL refers to a method of measuring the concentration
default location for sensors. of a combustible gas where the range of the sensor is set to
correspond with the concentration of gas that is below the
Calibration explosive range. In this case the Lower Explosive Limit equals
Instrument calibration refers to exposing the instrument to a 100% LEL.
known quantity of the measured substance (real or simulated)
and resetting the instrument if required. This verifies that the national Electric Code (nEC)
instrument is operating properly and adjusts for any sensor A compilation of requirements for electrical installation
drift. For gas detection equipment this involves exposing the practices, predominately employed in the USA as a criteria
sensor to a known concentration of the target gas, usually for such installations. Revised by the NEC Committee for the
from a calibration gas cylinder, and resetting the instrument to National Fire Protection Agency (NFPA).
adjust for sensor drift.
national Electrical Manufacturer’s Association (nEMA)
Combustible Gases A trade association propagating standards for industrial
Combustible gases are those that are monitored because they electrical equipment, notably enclosure.
present a risk of explosion or fire.
nitrogen Oxides
Cross-sensitivity A group of compounds most commonly found in vehicle
Cross-sensitivity refers to the response of a sensor to a gas exhaust, where nitrogen oxides are a byproduct of combustion
other than the target gas (also called an interference gas). formed from the nitrogen and oxygen in the air. In exhaust, the
most common is nitric oxide (NO) followed by nitrogen dioxide
Hazardous Area (Class-1) (NO2). Other nitrogen oxides found in much smaller quantities
An area in which flammable gas or vapour could exist under are N2O, N2O3, N2O4, N2O5, N3O4, and NO3.
normal or abnormal operations in potentially explosive
concentrations. Classified as probability of occurance (Class) nonincendive
and type of material (Group) in the NEC. Equipment that will not release sufficient energy in its normal
working condition to ignite a specfic hazardous atmospheric
Indoor Air Quality (IAQ) mixture.
IAQ is the physical, chemical, and biological characteristics
of indoor air. This environment is created by the interaction normally Open/Closed Relay Contacts
of the site, the climate, the building system, the potential Condition of relay contacts, open or closed, when power to the
contaminant sources (ie: furnishings, moisture sources, work equipment is off.
processes and activities, and outdoor pollutants) and the
building occupants. nOx
An abbreviation for nitric oxide.
Ignition-capable
Equipment that may have sparking contacts or hot surfaces ppm
that release sufficient energy in normal operation to ignite a Parts Per Million. 100% volume equals 1,000,000 “parts” , 1%
flammable atmosphere. volume equals 10,000 “parts”.
74 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
SENSOR MOUNTING
Sensors should be placed near the source of the gas if possible. For
example, near the compressor or piping.
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 75
FREQUENTLY ASKED QUESTIONS (FAQ)
76 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Are some gases lighter than others? Disadvantages
All substances have a molecular weight determined Broad spectrum, non-specific, not as accurate
by the number and type of atoms in the molecule. as other types.
In a gaseous state, the larger and heavier the
molecule, the heavier the gas. Electrochemical
Advantages
Accurate, repeatable, more gas specific, defined
What are the molecular weights of gases? cross sensitivities.
Molecular weight of some common gases: Disadvantages
Air 29 Relatively short life, moderately expensive.
Ammonia (NH3) 17 Catalytic
Carbon Monoxide (CO) 28 Advantages
Carbon Dioxide (CO2) 44 Range 0 - 100% LEL for many combustible
gases, accurate, long life.
Chlorine (Cl2) 71 Disadvantages
Hydrogen (H2) 2 Moderately expensive, can be poisoned.
Hydrogen Sulphide (H2S) 34
Infrared
Methane (CH4) 16 Advantages
Oxygen (O2) 32 Very gas specific, best way to detect CO2, very
Ozone (O3) 48 accurate & stable, long life.
Disadvantages
Nitric Oxide (NO) 30 Expensive.
Nitrogen Dioxide (NO2) 46
Propane (C3H8) 44
Does gas detection equipment need
maintenance and calibration?
Are there many types of sensors used for gas Yes. Maintenance on a properly installed, quality
detection? system is minimal and need only consist of a visual
There are many sensors used to detect gases. Some inspection and verification of operation. Calibration
gases can be detected by some sensors and not by frequency depends on sensor type and application.
others, and some sensors are more accurate or gas-
specific than others. Types of sensors include Solid Typical frequency for commercial applications is 1 - 2
State (also known as Metal Oxide Semiconductor), times per year. For areas where health hazards may
Electrochemical, Catalytic, Infrared, PID and others. exist, 3 - 4 times per year.
This verifies that the instrument is operating properly Where does CO2 come from?
and adjusts for any sensor drift. For gas detection Carbon Dioxide is a naturally occurring gas in air (less
equipment this involves exposing the sensor to a than 1%) and since it is exhaled during respiration, it
known concentration of the target gas, usually from a is often used as an indicator of Indoor Air Quality. CO2
calibration gas cylinder, and resetting the instrument is produced in the combustion of organic compounds
to adjust for sensor drift. and it is also formed during fermentation. CO2 is used
in many industrial and food & beverage applications
and may present a hazard if it leaks from cylinders.
Can gas detection equipment produce energy
savings?
Yes. A properly installed, maintained and calibrated What are nitrogen Oxides?
gas detection system can produce significant energy A group of compounds most commonly found
savings by running ventilation fans only when in vehicle exhaust, where Nitrogen Oxides are a
required, minimizing energy usage and expense. byproduct of combustion formed from the Nitrogen
and Oxygen in the air.
What does % LEL mean? Interference gases: Solvent fumes from warehoused
Combustible gases form flammable mixtures with air. products
For each gas there is an explosive range within which
the fuel to air mixture will support combustion. LEL
is an abbreviation for Lower Explosive Limit, which What gases are present in repair garages?
is the minimum concentration of each gas in air that Vehicle exhaust gases: CO, Nitrogen Oxides
must be present for combustion or explosion to occur.
Combustible gases from fuel leakage: Propane,
% LEL refers to a method of measuring the Gasoline, Methane
concentration of a combustible gas where the
range of the sensor is set to correspond with the Interference gases: Solvent fumes
concentration of gas that is below the explosive
range. In this case the Lower Explosive Limit equals
100 % LEL.
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 79
FREQUENTLY ASKED QUESTIONS (FAQ)
What is an Indoor Air Quality Monitor and how What gases can be detected with CETCI’s
can it help me? portable indoor air quality instruments?
An indoor air quality monitor samples the air Ammonia NH3
continuously until downloaded; producing an analysis
of the air quality based on the channels/gases Arsine AsH3
supplied. Carbon Dioxide CO2
Carbon Monoxide CO
YES Monitors measure IAQ on 3 basic levels;
Temperature, Relative Humidity and Carbon Dioxide. Chlorine Cl2
By recording samples from all three variables Chlorine Dioxide ClO2
simultaneously over a period of time, one is able to Combustible Gases n/a
analyze where and when the air quality is poor in
the workplace. Once the source has been determined Ethylene C2H4
then proper ventilation can be installed or altered. Ethylene Oxide C2H4O
Fluorine F2
** Low RH causes skin to become dry leading to What problems does poor indoor air quality
chapping and irritation, increases static electricity cause?
hindering computer operation. Many experience these symptoms without
realizing that they can be alleviated through proper
** High RH levels can result in condensation and thus ventilation.
the development of molds and fungi.
Sick Building Syndrome
High temperature and humidity levels can increase A set of symptoms related to chemical, particulate
the concentrations of some pollutants. or biological exposure that cannot be related to a
specific cause but are alleviated when the occupant
To obtain an accurate reading of pollutants levels, leaves the building. Individuals report symptoms such
it is necessary to take into account these levels and as headaches, nausea, fatigue and drowsiness, eye,
balance the temperature and relative humidity with nose, and throat irritation.
the carbon dioxide levels.
Building-Related Illness
A specific illness with a known cause that is a
Why use Carbon Dioxide levels to determine result of exposure to an indoor agent. Examples are
ventilation? Legionnaire’s disease and Pontiac Fever.
Carbon dioxide is an odorless, colorless gas produced
through human metabolism.
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 81
Product Codes
GaS dEtECtion ControllEr
PDC Multi-Channel Controller
PDC series, up to 2 analog inputs PDC-A02
PDC series, up to 8 analog inputs PDC-A08
PDC series, up to 8 digital inputs PDC-D08
PDC series, up to 24 digital inputs PDC-D24
PDC series, up to 16 digital inputs PDC-D16
PDC series, up to 32 digital inputs PDC-D32
PDC series, up to 64 digital inputs PDC-D64
PDC series, up to 96 digital inputs PDC-D96
PDC series, up to 128 digital inputs PDC-D128
Accessories
Relay module, 8 relays each, remote RRM-8
Analog output module, 8 4 - 20 mA outputs each RAO-8
Power supply, 24 V, remote RPS-24V
CAN network bridge CNB-2
Strobe & horn combo, remote RSH-24
Annunciator, remote RAP-128
Metal protective guard, large, 16 gauge, galvanized metal guards for controllers SCS-8000-SPG
82 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
GEM series, integral & remote sensors, carbon monoxide (CO) GEM-DECO-ECO
GEM series, integral carbon monoxide (CO), remote combustible gases (solid state) GEM-DECO-SCB
GEM series, integral carbon monoxide (CO), remote methane (CH4) GEM-DECO-SCB
GEM series, integral carbon monoxide (CO), remote propane (C3H8) GEM-DECO-SCB
GEM series, integral carbon monoxide (CO), remote nitrogen dioxide (NO2) GEM-DECO-END
GEM series, integral carbon monoxide (CO), remote nitric oxide (NO) GEM-DECO-ENO
GEM series, integral & remote sensors, oxygen (O2) GEM-DEO2-EO2
GEM series, integral & remote sensors, nitrogen dioxide (NO2) GEM-DEND-END
GEM series, integral & remote sensors, nitric oxide (NO) GEM-DENO-ENO
GEM series, integral, carbon monoxide (CO) & nitrogen dioxide (NO2) GEM-EECO-END
GEM series, integral, carbon monoxide (CO) & nitric oxide (NO) GEM-EECO-ENO
GEM series, integral, carbon monoxide (CO) & oxygen (O2) GEM-EECO-EO2
GEM series, integral, carbon monoxide (CO) & sulphur dioxide (SO2) GEM-EECO-ESO
GEM series, integral, nitrogen dioxide (NO2) & sulphur dioxide (SO2) GEM-EEND-ESO
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
Discontinued
AST-IRT series, freezer room model, Refrigerants R12, 0 - 2,000 ppm
AST-IRT series, chiller room model, Refrigerants R22, 0 - 2,000 ppm
AST-IRT-F-R12
AST-IRT-C-R22
AST-IRT series, freezer room model, Refrigerants R22, 0 - 2,000 ppm AST-IRT-F-R22
84 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
AST-IRT series, chiller room model, Refrigerants R114, 0 - 2,000 ppm AST-IRT-C-R114
AST-IRT series, freezer room model, Refrigerants R114, 0 - 2,000 ppm AST-IRT-F-R114
AST-IRT series, chiller room model, Refrigerants R123, 0 - 2,000 ppm AST-IRT-C-R123
AST-IRT series, freezer room model, Refrigerants R123, 0 - 2,000 ppm AST-IRT-F-R123
AST-IRT series, chiller room model, Refrigerants R134A, 0 - 2,000 ppm AST-IRT-C-R134A
AST-IRT series, freezer room model, Refrigerants R134A, 0 - 2,000 ppm AST-IRT-F-R134A
AST-IRT series, chiller room model, Refrigerants R401A (MP89), 0 - 2,000 ppm AST-IRT-C-R401A
AST-IRT series, freezer room model, Refrigerants R401A (MP89), 0 - 2,000 ppm AST-IRT-F-R401A
AST-IRT series, chiller room model, Refrigerants R401B (MP66), 0 - 2,000 ppm AST-IRT-C-R401B
AST-IRT series, freezer room model, Refrigerants R401B (MP66), 0 - 2,000 ppm AST-IRT-F-R401B
AST-IRT series, chiller room model, Refrigerants R402A (HP80), 0 - 2,000 ppm AST-IRT-C-R402A
Discontinued
AST-IRT series, freezer room model, Refrigerants R402A (HP80), 0 - 2,000 ppm AST-IRT-F-R402A
AST-IRT series, chiller room model, Refrigerants R404A (HP62), 0 - 2,000 ppm AST-IRT-C-R404A
AST-IRT series, freezer room model, Refrigerants R404A (HP62), 0 - 2,000 ppm AST-IRT-F-R404A
AST-IRT series, chiller room model, Refrigerants R407C (9000), 0 - 2,000 ppm AST-IRT-C-R407C
AST-IRT series, freezer room model, Refrigerants R407C (9000), 0 - 2,000 ppm AST-IRT-F-R407C
AST-IRT series, chiller room model, Refrigerants R408A (FX10), 0 - 2,000 ppm AST-IRT-C-R408A
AST-IRT series, freezer room model, Refrigerants R408A (FX10), 0 - 2,000 ppm AST-IRT-F-R408A
AST-IRT series, chiller room model, Refrigerants R409A (FX56), 0 - 2,000 ppm AST-IRT-C-R409A
AST-IRT series, freezer room model, Refrigerants R409A (FX56), 0 - 2,000 ppm AST-IRT-F-R409A
AST-IRT series, chiller room model, Refrigerants R500, 0 - 2,000 ppm AST-IRT-C-R500
AST-IRT series, freezer room model, Refrigerants R500, 0 - 2,000 ppm AST-IRT-F-R500
AST-IRT series, chiller room model, Refrigerants R502, 0 - 2,000 ppm AST-IRT-C-R502
AST-IRT series, freezer room model, Refrigerants R502, 0 - 2,000 ppm AST-IRT-F-R502
AST-IRT series, chiller room model, Refrigerants R507A (AZ50), 0 - 2,000 ppm AST-IRT-C-R507A
AST-IRT series, freezer room model, Refrigerants R507A (AZ50), 0 - 2,000 ppm AST-IRT-F-R507A
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 85
Product Codes
AST-IS series, carbon dioxide (CO2), wall mount with IP54 industrial enclosure
AST-IS7
& LCD digital display
AST-IS series, carbon dioxide (CO2) & temperature sensor, duct mount AST-IS8
AST-IS series, carbon dioxide (CO2) & temperature sensor,
AST-IS9
duct mount with LCD digital display
AST-IS series, carbon dioxide (CO2) & temperature sensor, wall mount AST-IS10
AST-IS series, carbon dioxide (CO2) & temperature sensor, wall mount
AST-IS11
with LCD digital display
AST-IS series, carbon dioxide (CO2), relay & temperature sensor, wall mount with LCD
AST-IS12
digital display & relay
AST-IS series, carbon dioxide (CO2) & temperature sensor, wall mount with IP54
AST-IS13
industrial enclosure & relay
AST-IS series, carbon dioxide (CO2), wall mount with LCD digital display
AST-IS14
& audible alarm
AST-IS series, carbon dioxide (CO2), wall mount VAV with hidden LCD digital display AST-IS15
AST-IS series, carbon dioxide (CO2), wall mount VAV with LCD digital display AST-IS16
AST-IS series, carbon dioxide (CO2), duct mount with LCD digital display AST-IS17
AST-IS series, carbon dioxide (CO2), wall mount with IP54 industrial enclosure,
AST-IS18
0 - 6% volume
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
86 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 87
Product Codes
PET BACnet® Transmitters
PET series, single channel, ammonia (NH3), 0 - 500 ppm PET-EAM
PET series, single channel, carbon monoxide (CO), 0 - 200 ppm PET-TCO
PET series, single channel, combustible gases (solid state), 0 - 50% LEL PET-SCB
PET series, single channel, ethylene (C2H4), 0 - 2,000 ppm PET-EC4
PET series, single channel, formaldehyde (CH2O), 0 - 10 ppm PET-EFO
PET series, single channel, hydrogen (H2), 0 - 2,000 ppm PET-EH2
PET series, single channel, methane (CH4), 0 - 50% LEL PET-SCB
PET series, single channel, nitrogen dioxide (NO2), 0 - 10 ppm PET-END
PET series, single channel, nitric oxide (NO), 0 - 100 ppm PET-ENO
PET series, single channel, oxygen (O2), 0 - 25% volume PET-OO2
PET series, single channel, propane (C3H8), 0 - 50% LEL PET-SCB
PET series, single channel, refrigerants (R12, R22, R134A, R401A, R402A, R404A,
PET-SR2
R407C, R410A, R422A, R422D, R438A, R507), 0 - 2,000 ppm
PET series, single channel, sulphur dioxide (SO2), 0 - 20 ppm PET-ESO
PET series, single channel, TVOCs (solid state), 0 - 500 ppm PET-SOS
PET series, dual channel, ammonia (NH3) & nitric oxide (NO) PET-EAM-ENO
PET series, dual channel, ammonia (NH3) & nitrogen dioxide (NO2) PET-EAM-END
PET series, dual channel, ammonia (NH3) & sulphur dioxide (SO2) PET-EAM-ESO
PET series, dual channel, ammonia (NH3) & oxygen (O2) PET-EAM-OO2
PET series, dual channel, carbon monoxide (CO) & nitric oxide (NO) PET-TCO-ENO
PET series, dual channel, carbon monoxide (CO) & nitrogen dioxide (NO2) PET-TCO-END
PET series, dual channel, carbon monoxide (CO) & sulphur dioxide (SO2) PET-TCO-ESO
PET series, dual channel, carbon monoxide (CO) & oxygen (O2) PET-TCO-OO2
PET series, dual channel, ethylene (C2H4) & nitric oxide (NO) PET-EC4-ENO
PET series, dual channel, ethylene (C2H4) & nitrogen dioxide (NO2) PET-EC4-END
PET series, dual channel, ethylene (C2H4) & sulphur dioxide (SO2) PET-EC4-ESO
PET series, dual channel, ethylene (C2H4) & oxygen (O2) PET-EC4-OO2
PET series, dual channel, formaldehyde (CH2O) & nitric oxide (NO) PET-EFO-ENO
PET series, dual channel, formaldehyde (CH2O) & nitrogen dioxide (NO2) PET-EFO-END
PET series, dual channel, formaldehyde (CH2O) & sulphur dioxide (SO2) PET-EFO-ESO
PET series, dual channel, formaldehyde (CH2O) & oxygen (O2) PET-EFO-OO2
PET series, dual channel, hydrogen (H2) & nitric oxide (NO) PET-EH2-ENO
PET series, dual channel, hydrogen (H2) & nitrogen dioxide (NO2) PET-EH2-END
PET series, dual channel, hydrogen (H2) & sulphur dioxide (NO2) PET-EH2-ESO
PET series, dual channel, hydrogen (H2) & oxygen (O2) PET-EH2-OO2
PET series, dual channel, nitric oxide (NO) & nitrogen dioxide (NO2) PET-ENO-END
PET series, dual channel, nitric oxide (NO) & sulphur dioxide (SO2) PET-ENO-ESO
PET series, dual channel, nitric oxide (NO) & oxygen (O2) PET-ENO-OO2
PET series, dual channel, nitrogen dioxide (NO2) & sulphur dioxide (SO2) PET-END-ESO
PET series, dual channel, nitrogen dioxide (NO2) & oxygen (O2) PET-END-OO2
PET series, dual channel, oxygen (O2) & sulphur dioxide (SO2) PET-OO2-ESO
88 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
Options (to be added to the end of the product codes)
LED digital display N
Remote housing (solid state sensor only) R
4 - 20 mA analog transmitter (solid state sensor only) A
Water / dust tight enclosure W
Splash guard (for watertight enclosure only) S
Accessories
Calibration kit, 15 L or 17 L cylinders, 0.5 LPM flow regulator CET-8000-CK1
Calibration kit, 34 L, 58 L, 75 L, or 103 L cylinders, 0.5 LPM flow regulator CET-7150-CK1
Metal protective guard, small, 16 gauge, galvanized metal guards for transmitters SCS-8000-RSG
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 89
Product Codes
Hydrogen sulphide (H2S) electrochemical, 0 - 50 ppm PNP-L
Nitric oxide (NO) electrochemical, 0 - 100 ppm PNP-E
Nitrogen dioxide (NO2) electrochemical, 0 - 5 ppm PNP-D
Oxygen (O2) electrochemical, 0 - 25% volume PNP-F
Ozone (O3) electrochemical, 0 - 1 ppm PNP-G
Phosphine (PH3) electrochemical, 0 - 1 ppm PNP-V
Silane (SiH4) electrochemical, 0 - 1 ppm PNP-W
Sulphur dioxide (SO2) electrochemical, 0 - 20 ppm PNP-P
TVOCs (PID), 0 - 300 ppm PNP-Y+
TVOCs (PID), 0 - 50 ppm PNP-Z+
External mounted nickel metal hydride pack YESAIR BATT OPTION
Accessories
Hard shell carrying case for YESAIR 6010.20
YES logger package, 2 GB flash card, USB cable, YES Viewer software,
YESAIR-LGRPKG
SD flash card reader
Handheld probe 10” with 30” of sample hose YES-HHPROBE-10
External lead acid battery, in carrying case w charger YES-AIR BATT EXT
YES Viewer information logging software CD YES-SFTWRE
Accessories
Hard shell carrying case for YES Plus LGA 718
YES logger package, 2 GB flash card, USB cable, YES Viewer software,
YESAIR-LGRPKG
SD flash card reader
Handheld probe 10” with 30” of sample hose YES-HHPROBE-10
YES Viewer information logging software CD YES-SFTWRE
Discontinued
YESAIR Junior Essential Air Quality Monitor
YESAIR Junior, carbon dioxide (CO2), temperature & relative humidity sensors plus
YESAIR Junior
internal data logging, YES Viewer software, USB cable & carrying case
Accessories
YES logger package, 2 GB flash card, USB cable, YES Viewer software,
YESAIR-LGRPKG
SD flash card reader
YES Viewer information logging software CD YES-SFTWRE
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 91
Notes
92 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 93
Notes
94 | © 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link]
© 2012 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | [Link] | 95
Lai Chi Kok [Hong Kong, China] | Canada Post [across BC] | Revenue Canada Surrey Taxation Centre
[Surrey, BC] | British Columbia Ambulance Service [across BC] | Insurance Corporation of
British Columbia [across BC] | Canada Place [Vancouver , BC] | Centre for Disease Control [Vancouver,
BC] | Envirotest Canada [Across Vancouver Lower Mainland] | Hong Kong International Airport [Hong
Kong, China] | International Bio Recovery [North Vancouver, BC] | Labatt Brewery [New Westminster, BC]
| Purolator [across Canada & USA] | Johns Hopkins Hospital [Baltimore, MD] | Vancouver General
Hospital Hyperbaric Chamber [Vancouver, BC] | Fedex [across Canada & USA] | University of Victoria
[Victoria, BC] | CN Railway [Richmond, BC] | Lennox Industries [Carrollton, TX] | Pacific Centre [Vancouver,
BC] | Saskatoon Airport [Saskatoon, SK] | Lulu Island Wastewater Treatment Plant [Richmond, BC]
| Canadian Coast Guard [Victoria, BC] | BC Ferries Horseshoe Bay [North Vancouver, BC] | Canadian
Springs [Richmond, BC] | Canadian Food Inspection Agency [Burnaby, BC] | Toronto International
Airport [Toronto, ON] | Metro Commercial Building [Seattle, WA] | City Centre Mall [Edmonton, AB]
| Coquitlam Aquatic [Coquitlam, BC] | Costco [Burnaby, BC] | University of British Columbia
[Vancouver, BC] | Lucerne Foods [Lethbridge, AB] | Halliburton [Offshore Rig, NL] | Canadian Forces Base
[Comox & Esquimalt, BC] | Metropolis at Metrotown [Burnaby, BC] | Seaspan International [N Vancouver,
BC] | Marriott Hotel [Whistler, BC] | Harbor Yard Arena [Bridgeport, CT] | UBC TRIUMF [Vancouver, BC]...
...and many more.
© 2012 Critical Environment Technologies Canada Inc. All rights reserved. Data in this publication may change without notice.