DM4370
10G CARRIER ACCESS SWITCH
INSTALLATION GUIDE
204.4314.02 – October/2019
DM4370 – Installation Guide Legal Note
LEGAL NOTE
In spite the fact that all the precautions were taken in development of the present
document, DATACOM shall not be held responsible for eventual errors or omissions as
well as no obligation is assumed due to damages resulting from the use of the
information included in this guide. The specifications provided in this manual shall be
subject to changes with no prior notification and are not acknowledged as any type of
contract.
© 2019 DATACOM - All rights reserved.
WARRANTY
DATACOM's products are covered by a warranty against manufacturing defects during a
minimum period of 12 (twelve) months including the legal term of 90 days, as from the
date of issue of the supply Nota Fiscal (Invoice).
Our warranty is standard counter warranty, this means, for exercise of the warranty,
the customer should send the product to DATACOM Authorized Technical Assistance
with paid freight. The return freight of the equipment will be DATACOM responsibility.
To obtain additional information, see our warranty policy in
www.datacom.com.br/en/home
Telephone Number: +55 51 3933-3094
204.4314.02 – October/2019 2
DM4370 – Installation Guide Contacts
CONTACTS
TECHNICAL SUPPORT
Datacom has available a support portal - DmSupport, to help the customers in use and
config of our equipment.
Access to the DmSupport can be made through link:
https://supportcenter.datacom.com.br
In this site the following are available: firmwares, technical datasheets, config guide,
MIBs and manuals for download. In addition, it allows opening of calls for assistance
with our technical team.
Telephone Number: +55 51 3933-3122
We would like to highlight that our assistance through telephone support is available
from Monday through Friday from 08:00 AM through 05:30 PM.
Important: For support assistance 24x7, please request a quotation to our sales
department.
GENERAL INFORMATION
For any other additional information, please visit the www.datacom.com.br/en/home
or call:
DATACOM
Rua America, 1000
92990-000 – Eldorado do Sul – RS – Brazil
+55 51 3933-3000
204.4314.02 – October/2019 3
DM4370 – Installation Guide Product Documentation
PRODUCT DOCUMENTATION
ABOUT THIS DOCUMENT
This document is part of a set of documents prepared to provide all necessary
information about
DATACOM products.
SOFTWARE PLATFORM
QUICK CONFIGURATION GUIDE – Provides instructions on how to set
the functionalities in a quick manner in the equipment
TROUBLESHOOTING GUIDE – Provides instructions on how to analyze,
identify and solve problems with the product
COMMAND REFERENCE – Provides all the commands related to the
product
RELEASE NOTES – Provides instructions on the new functionalities,
identified defects and compatibilities between Software and Hardware
HARDWARE PLATFORM
DATASHEET – Provides the product technical characteristics
INSTALLATION GUIDE – Provides instructions on the procedures
covering product installation
The availability of some documents can vary depending on the type of product.
Access https://supportcenter.datacom.com.br/ to locate the related documents or
contact the Technical Support for additional information.
204.4314.02 – October/2019 4
DM4370 – Installation Guide Contents
CONTENTS
LEGAL NOTE ............................................................................................................................................................................... 2
WARRANTY ................................................................................................................................................................................. 2
CONTACTS .................................................................................................................................................................................. 3
TECHNICAL SUPPORT...................................................................................................................................................... 3
GENERAL INFORMATION................................................................................................................................................ 3
PRODUCT DOCUMENTATION................................................................................................................................................ 4
ABOUT THIS DOCUMENT ............................................................................................................................................... 4
SOFTWARE PLATFORM .................................................................................................................................................. 4
HARDWARE PLATFORM ................................................................................................................................................. 4
CONTENTS .................................................................................................................................................................................. 5
1 INTRODUCING THE HARDWARE INSTALLATION GUIDE ...................................................................................... 7
1.1 ABOUT THIS GUIDE ............................................................................................................................................ 7
1.2 INTENDED AUDIENCE ........................................................................................................................................ 7
1.3 CONVENTIONS ...................................................................................................................................................... 7
2 GETTING STARTED.......................................................................................................................................................... 9
2.1 SAFETY WARNINGS............................................................................................................................................ 9
3 HARDWARE SPECIFICATIONS ................................................................................................................................... 10
3.1 PRODUCT OVERVIEW ..................................................................................................................................... 10
3.2 PWR LED (POWER) ...................................................................................................................................... 10
3.3 ALARM/FAIL LED............................................................................................................................................. 10
3.4 CONSOLE INTERFACE ..................................................................................................................................... 11
3.5 ETHERNET MANAGEMENT INTERFACE ................................................................................................... 12
3.6 USB INTERFACE DEVICE (CONSOLE) .................................................................................................... 13
3.7 DATA INTERFACES ........................................................................................................................................... 13
3.8 POWER INPUTS ................................................................................................................................................. 15
4 INSTALLING THE DM4370 .......................................................................................................................................... 18
4.1 DM4370 SWITCH PACKAGE CONTENTS ............................................................................................. 18
4.2 IDENTIFYING THE PRODUCT........................................................................................................................ 19
4.3 PREPARING THE SITE ..................................................................................................................................... 19
4.4 19-INCH RACK INSTALLATION .................................................................................................................. 20
4.5 DESKTOP INSTALLATION .............................................................................................................................. 21
4.6 CONNECTING THE POWER SUPPLY ......................................................................................................... 21
4.7 CHECKING THE SWITCH’S OPERATION ................................................................................................. 21
204.4314.02 – October/2019 5
DM4370 – Installation Guide Contents
5 INSTALLING AND REMOVING TRANSCEIVERS ..................................................................................................... 23
5.1 INSTALLING SFP/SFP+ MODULES ........................................................................................................ 24
5.2 REMOVING SFP/SFP+ MODULES .......................................................................................................... 24
6 LOGGING IN FOR FIRST TIME..................................................................................................................................... 26
6.1 CONNECTING BY CONSOLE INTERFACE ............................................................................................. 26
6.2 CONFIGURING A MANAGEMENT INTERFACE ....................................................................................... 26
6.3 DEFAULT ACCOUNT......................................................................................................................................... 27
6.4 CHANGING DEFAULT ADMINISTRATOR ACCOUNT PASSWORD ................................................ 28
7 TECHNICAL SPECIFICATION ....................................................................................................................................... 29
7.1 INTERFACES ........................................................................................................................................................ 29
7.2 POWER SUPPLY ................................................................................................................................................ 29
7.3 PHYSICAL SPECIFICATIONS ......................................................................................................................... 29
7.4 ENVIRONMENTAL INFORMATION .............................................................................................................. 30
8 STANDARDS AND REGULATIONS............................................................................................................................ 31
204.4314.02 – October/2019 6
DM4370 – Installation Guide Introducing the Hardware Installation Guide
1 INTRODUCING THE HARDWARE INSTALLATION GUIDE
1.1 ABOUT THIS GUIDE
This manual provides information about hardware specification and installation
procedures from DM4370 switch. This document also covers initial configuration, those
normally needed after hardware installation.
It is assumed that the individual or individuals managing any aspect of this product
have basic understanding of Ethernet and Telecommunications networks.
1.2 INTENDED AUDIENCE
The DM4400 Hardware Installation Guide is intended for Network Administrators,
technicians and other qualified service personnel responsible for installing, configuring,
planning and maintaining the DM4370 platform.
1.3 CONVENTIONS
In order to improve the agreement, the following conventions are made throughout this
guide:
1.3.1 Icons Convention
Icon Type Description
Notes give an explanation about some topic in the foregoing
Note
paragraph.
This symbol means that this text is very important and, if
Caution the orientations were not correct followed, it may cause
damage or hazard.
This symbols means that, case the procedure was not
Warning
correctly followed, may exist electrical shock risk.
Represents LASER radiation. It is necessary to avoid eye and
Warning
skin exposure.
Indicates that equipment, or a part is ESDS (Electrostatic
Caution Discharge Sensitive). It should not be handled without
grounding antistatic wrist strap or equivalent.
Warning Non-ionizing radiation emission.
204.4314.02 – October/2019 7
DM4370 – Installation Guide Introducing the Hardware Installation Guide
WEEE Directive Symbol (Applicable in the European Union
and other European countries with separate collection
systems).This symbol on the product or its packaging
indicates that this product must not be disposed of with
other waste. Instead, it is your responsibility to dispose of
your waste equipment by handing it over to a designated
collection point for the recycling of waste electrical and
Note electronic equipment. The separate collection and recycling
of your waste equipment at the time of disposal will help
conserve natural resources and ensure that it is recycled in
a manner that protects human health and the environment.
For more information about where you can drop off your
consumer waste equipment for recycling, please contact
your local city recycling office or the dealer from whom you
originally purchased the product.
A caution type notice calls attention to conditions that, if not avoided,
may damage or destroy hardware or software.
A warning type notice calls attention to conditions that, if not avoided,
could result in death or serious injury.
204.4314.02 – October/2019 8
DM4370 – Installation Guide Getting Started
2 GETTING STARTED
2.1 SAFETY WARNINGS
Before to continue, read carefully the following safety warnings:
Prior to installation carefully read the whole manual.
Pay attention to the safety instructions during installation, operation or
maintenance of this product. Installation, adjustments or maintenance
must be performed only by qualified, trained and authorized personnel.
To prevent the risk of electrical shocks, before turning the equipment on
or connecting an interface card or cable, install the protective grounding
system.
Some pieces of equipment in this guide have optical modules of LASER
emitting. Avoid exposure to eyes and skin.
The optical interface modules use transmitters with invisible LASER
radiation. Never look directly at the LASER terminals or the optical fiber.
Exposure to LASER emission may cause partial or total vision loss.
204.4314.02 – October/2019 9
DM4370 – Installation Guide Hardware Specifications
3 HARDWARE SPECIFICATIONS
This chapter describes the DM4370 switch hardware specifications.
3.1 PRODUCT OVERVIEW
This manual covers the DM4370 4GT+4GX+4XS product. The front panel of the switch
is shown below.
Figure 1 – DM4370 4GT+4GX+4XS front panel
More information on the switch’s capabilities can be found in the Technical
Specifications chapter.
3.2 PWR LED (POWER)
The PWR LED is an indicator that informs visually the status of the DM4370 power
supply. The table below shows the expected behavior for this indicator.
Color Status Description
- Off Switch is off
GREEN On Switch is off
Table 1 – PWR LED
3.3 ALARM/FAIL LED
The ALARM/FAIL LED is an indicator that visually informs the status of the operating
system, which is run on the DM4370. The table below shows the expected behavior for
this indicator.
Color Status Description
- Switch operating normally without failures or alarms
Off
detected
RED On Switch in hardware failure status
204.4314.02 – October/2019 10
DM4370 – Installation Guide Hardware Specifications
ORANGE On Switch in alarm status
Blinking Switch is in firmware update process
Table 2 – ALARM/FAIL LED
3.4 CONSOLE INTERFACE
The DM4370 switch has a console interface for the local management of the product.
The console interface uses an RJ45 connector and follows the RS232 (EIA/TIA 574)
standard. A cable with a male RJ45 connector and a female DB9 connector must be
used for the connection to a desktop or laptop.
The console interface on the RJ45 connector has two built-in LEDs that
have no functionality in the switch and remain turned off under any
operating conditions.
The console cable is an accessory included only in the collective package. Additional
cables are purchased separately via code 710.0137.xx or assembled as described in
the following illustrations. The pin assignment of the RJ45 connector and its match with
the DB9 connector is described in table below.
Figure 2 – Console cable
Figure 3 – RJ45 console cable connector pins
RJ45 DB9
Function DM4370 Input/Output
Male Female
1 - -
Reserved
2 - -
Reserved
2
3 RS232_T
Output
X
4 5
DGND Ground
204.4314.02 – October/2019 11
DM4370 – Installation Guide Hardware Specifications
5 5
DGND Ground
3
6 RS232_R
Input
X
7 - -
Reserved
8 - -
Reserved
Table 3 – Console interface connector pin assignment
3.5 ETHERNET MANAGEMENT INTERFACE
The DM4370 has a Copper Gigabit Ethernet interface for the dedicated management of
the switch, which operates on full-duplex 10/100/1000Base-T. For details on how to use
this interface, read the Ethernet Management Interface section.
Figure 4 – Ethernet Management Interface
Indicator Color Status Description
LINK/ACT GREEN Off Link Down (inactive interface)
On Link Up (active interface)
Blinking Data transmitting and/or receiving activity
SPEED YELLOW Off Interface operating in 1000Base-T mode
Interface operating in 10Base-T or
On
100Base-T mode
Table 4 – Management Interface Indicator LEDs
The switch’s Ethernet Management Interface does not support half-
duplex mode.
204.4314.02 – October/2019 12
DM4370 – Installation Guide Hardware Specifications
3.6 USB INTERFACE DEVICE (CONSOLE)
The switch provides a type B mini-USB device interface connector that operates in
console mode. The USB Console Interface is accessible via type B mini-USB adapter
cable to type A USB host (accessory not included with the switch). The driver to use this
interface in Windows can be found on the Datacom website. Contact Technical
Support for more information on using this interface.
3.7 DATA INTERFACES
3.7.1 Copper Ethernet Interfaces (10/100/1000Base-T)
The DM4370 switch has 4 copper Gigabit Ethernet interfaces in dedicated RJ45
connectors, numbered from 1 to 4 on the front panel. There are LINK/ACT and SPEED
LEDs that are built into the connectors corresponding to each interface, as shown
below.
Figure 5 – Copper Ethernet Interfaces and LED indication
The copper interfaces present the LED convention described in the table below to
indicate the operation and operating mode.
Indicato
Color Status Description
r
LINK/ACT GREEN Off Link Down (inactive interface)
On Link Up (active interface)
Blinking Data transmitting and/or receiving activity
SPEED YELLOW Off Port operating in 1000Base-T mode
On Port operating in 10Base-T or 100Base-T
Table 5 – Indicator LEDs of the copper Gigabit Ethernet interfaces
3.7.2 Gigabit Ethernet Interfaces (1000Base-X)
The DM4370 has 4 Gigabit Ethernet interfaces in dedicated SFP connectors and
numbered from 5 to 8 on the front panel. There are LINK/ACT and SPEED LEDs that are
built into the connectors corresponding to each interface, as shown below.
204.4314.02 – October/2019 13
DM4370 – Installation Guide Hardware Specifications
SPEEED
LINK/ACT
UPPER
PORT UPPER PORT
SPEED LINK/ACT
LOWER PORT LOWER PORT
Figure 6 – Gigabit Ethernet SFP Interfaces and LED indication
The LED convention to indicate the operation and mode of the interfaces is described in
the table below.
Indicato
Color Status Description
r
LINK/ACT GREEN Off Link Down (inactive interface)
On Link Up (active interface)
Data transmitting and/or receiving
Blinking
activity
SPEED YELLOW Interface operating in 10GBase-X
Off
mode
Interface operating in 1000Base-X
On
mode
Table 6 – Indicator LEDs of the Gigabit Ethernet SFP interfaces
3.7.3 SFP+ Gigabit Ethernet Interfaces (10GBase-X)
The DM4370 switch has 4 10 Gigabit Ethernet interfaces on dedicated SFP+ connectors
and numbered from 1 to 4 on the front panel. There are LINK/ACT and SPEED LEDs that
are built into the connectors corresponding to each interface, as shown below.
SPEE LINK/ACT
D
UPPER PORT
UPPER PORT
SPEED
LINK/ACT
LOWER
PORT
POWER PORT
Figure 7 – SFP+10 Gigabit Ethernet Interfaces and LED indication
204.4314.02 – October/2019 14
DM4370 – Installation Guide Hardware Specifications
The LED convention to indicate the operation and mode of the interfaces is described in
the table below.
Indicato
Color Status Description
r
Off Link Down (inactive interface)
On Link Up (active interface)
LINK/ACT GREEN
Data transmitting and/or receiving
Blinking
activity
SPEED YELLOW Interface operating in 10GBase-X
Off
mode
Interface operating in 1000Base-X
On
mode
R Table 7 – Indicator LEDs of the 10 Gigabit Ethernet SFP+ Interfaces
3.8 POWER INPUTS
The DM4370 switch has two independent power inputs on the rear panel, as shown in
figure below. The product is turned on and operates automatically if either input is
powered within the specified voltage levels.
Figure 8 – DM4370 Rear Panel
Additionally, the DM4370 switch supports redundant power supply and the
insertion/removal of power cables (hot swap), thus allowing uninterrupted operation if
one of the two power sources is turned off or fails.
The switch is de-energized through the power cable. The power outlet
must be nearby and easily accessible.
This switch depends on pre-installed protection against short circuits.
204.4314.02 – October/2019 15
DM4370 – Installation Guide Hardware Specifications
In the situation where both power inputs are connected and operating
with voltages within the specified range, the AC/DC power supply will
take precedence over the DC power supply.
3.8.1 AC/DC Power Input
This power input has an IEC 320/C14 plug and works both for direct connection in
conventional AC power (alternating current) as well as -48/60V DC power rails. The
switch is capable of automatically detecting the polarity, the type of input voltage used
(AC or DC) and adjusting its internal operation. Information about tolerated input limits,
power and current can be found in the Technical Specifications chapter.
The image below shows the plug’s grounding information.
Ground
POWER
Figure 9 – IEC 320/C14 plug grounding
According to the NBR 14136 standard the switch’s grounding pin must be connected to
the grounding installations of the site where it will be installed since the power pins
have no polarity indication.
3.8.2 DC Power Input
This power input has an IEC 320/C14 plug and works both for direct connection in
conventional AC power (alternating current) as well as -48/60V DC power rails. The
switch is capable of automatically detecting the polarity, the type of input voltage used
(AC or DC) and adjusting its internal operation. Information about tolerated input limits,
power and current can be found in the Technical Specifications chapter.
The image below shows the DC jack plug polarity information.
204.4314.02 – October/2019 16
DM4370 – Installation Guide Hardware Specifications
Figure 10 – DC Jack plug polarity
The external 12V power supply is a switch accessory, sold separately.
Use only external power supply provided by DATACOM. Consult
Technical Support for further information.
204.4314.02 – October/2019 17
DM4370 – Installation Guide Installing the DM4370
4 INSTALLING THE DM4370
This chapter explains the procedures, recommendations, and attention related to
installing the DM4370.
The DM4370 must be installed in a dry, ventilated location. The sides,
front panel and rear panel must remain unobstructed for proper switch
ventilation and air convection. Never support any type of material over
the switch.
The switch has a fan in the rear panel next to the power inputs to assist
in the switch’s heat dissipation. Never block the air vents while the
switch is in operation.
4.1 DM4370 SWITCH PACKAGE CONTENTS
The switch is wrapped in protective plastic bubble wrap and packaged in individual
cardboard boxes, in order to avoid damage to the product during shipping. Depending
on the size of the purchase order a set of individual boxes can be packed inside a
collective box, as shown in figure below.
A 1.5m power cord unit with 180° NBR14136 plug is available inside the individual box,
in addition to the switch itself.
Open the top of the collective packaging (if applicable) and the front of the individual
boxes and make sure that all of the items listed above are inside the package. Check
that the switches are not damaged. If there is anything wrong contact Technical
Support.
Figure 11 – Product packaging
204.4314.02 – October/2019 18
DM4370 – Installation Guide Installing the DM4370
4.2 IDENTIFYING THE PRODUCT
Check that the switch received matches the illustrations in this manual, as shown in
figure below.
The DM4370 switch has a label on the bottom of its mechanical base. It contains model
information, product code and serial number. Check if there is any divergent
information on the label in relation to the information present on the packaging.
4.3 PREPARING THE SITE
Before to install the equipment, some cares must be taken to guarantee a successfully
equipment deployment. The site planning process should consider the following
requirements:
Building,
Environment,
Equipment,
Cabling.
4.3.1 Building requirements
Verify that building and electrical installations are in according to all code specifications
(set of rules for building constructions) defined by governmental authority.
The construction of the site in question needs to be prepared to withstand mechanical
and electrical loads of the new switch being installed. See the Technical
Specifications to check relevant switch weight and power consumption information.
Be sure that the power supply circuit to the rack assembly is not
overloaded.
4.3.2 Environment requirements
Electrical equipment generates a significant amount of heat. Therefore, it is essential to
provide a temperature-controlled environment for assure performance and safety.
Additionally to temperature control, it is also necessary to install the equipment only in
a humidity-controlled area that is free of airborne materials that can conduct electricity.
Remember that too much humidity can cause a fire and too little humidity can produce
electrical shock and fire.
4.3.3 Equipment requirements
To ensure correct operation, when you install the DM4370 switch observe the
information available in Physical Specifications and Environmental Information
sections.
204.4314.02 – October/2019 19
DM4370 – Installation Guide Installing the DM4370
4.4 19-INCH RACK INSTALLATION
The DM4370 switch can be installed on 19-inch racks using the MA-01 accessory (sold
separately through 800.0141.xx code). Up to two DM2100 (EDDsII), DM2300, DM2500
and DM4370 units can be arranged side by side, occupying 1U in height.
Remove the screws securing the front rubber feet of the switch using a Phillips
screwdriver, and use the same screws and the same hole to secure the DM4370 switch
to the adapter, as shown in the image below.
Figure 12 – MA-01
After installing the switch to the adapter, place the assembly on the rack and insert two
standard M5 screws (not shipped with the switch) into each side ear of the adapter to
secure the assembly to the rack’s cage nuts (not shipped with the product). Finally,
tighten the screws to ensure that the assembly is securely attached to the rack.
Figure 13 – Installation of the MA-01 to a 19-inch rack
204.4314.02 – October/2019 20
DM4370 – Installation Guide Installing the DM4370
4.5 DESKTOP INSTALLATION
The DM4370 switch has tabletop rubber feet, as shown below. Choose a flat surface
near to an AC or DC power source to install the switch.
Figure 14 – DM4370 bottom view
4.6 CONNECTING THE POWER SUPPLY
The DM4370 switch features two independent power inputs on the rear panel. The
switch can operate normally if either of the two inputs is powered according to the
expected voltage and current levels. Refer to Power Input and Technical
specification sections for additional information on how to connect the power inputs.
4.7 CHECKING THE SWITCH’S OPERATION
Considering that the DM4370 switch was installed according to the guidelines in this
manual, the steps below indicate if the switch is operating normally.
Step Description
Immediately after the unit is powered by any of the power inputs,
Step 1
the green PWR LED should light up immediately
You should be able to see the fan, positioned at the rear panel,
Step 2
moving after the switch is turned on.
Table 8 – Operating normally
204.4314.02 – October/2019 21
DM4370 – Installation Guide Installing the DM4370
Find further information on the expected LED behavior in Hardware Specifications
chapter.
Once the initialization process has been completed successfully, the operator must
configure the switch’s management as indicated in the Accessing the Switch section.
204.4314.02 – October/2019 22
DM4370 – Installation Guide Installing and Removing Transceivers
5 INSTALLING AND REMOVING TRANSCEIVERS
There may be restrictions for the use of copper SFP and 100Base-FX SFP
modules in the SFP/SFP+ cages. Consult Technical Support for a list of
modules tested with this switch.
This chapter describes how SFP/SFP+ modules should be installed and removed. It also
provides information about the DATACOM guidelines for the cleaning and storage of
modules and optical fibers.
SFP (Small Form-factor Pluggable) and SFP+ modules are inserted into the SFP/SFP+
cages, operating as transceivers between the switch and the selected optical
communication path.
In order to ensure durability and good performance of the switch, it is very important to
follow the guidelines described below.
Care with the Optical Cords:
Keep optical cords that are currently not in use with their protective
cap. The core of the optical cords can become dirty and result in loss of
performance just by being stored without their protective cap, even if
stored in an appropriate cabinet;
Clean the optical cords core before using them. To clean them it is
necessary to use only specific cleaning material. Any other material used
to clean the optical cord core may result in loss of performance or even
irreparable damage to the cords.
Care with the Optical Modules:
In order to handle the optical modules, it is always necessary to use
an antistatic wrist strap;
In order to transport and store the optical modules, it is always
necessary to do so in their original packaging to prevent any physical or
electrostatic damage.
When performing any maintenance to the switch, make sure the
maintenance technician is using the appropriate protections. Grounding
(the use of an antistatic wrist strap) can prevent damage to the
operator's health and damage to the switch.
The SFP/SFP+ modules provided by DATACOM meet INF-8074i and IEC
60825-1 specifications. Modules that are not approved do not guarantee
correct operation of the switch and might damage it. Please contact
Technical Support for more information on the risks of using non-
approved modules and the possibility of their use.
204.4314.02 – October/2019 23
DM4370 – Installation Guide Installing and Removing Transceivers
Optical modules employ invisible radiation laser transmitters. Never look
directly at the terminals of a module or optical cord. Exposure to laser
emissions may cause partial or total loss of vision.
5.1 INSTALLING SFP/SFP+ MODULES
Follow the steps below to install SFP/SFP+ modules to the switch.
Step 1 Insert the module into the SFP or SFP+ slot and push it in until it is
firmly inserted, as shown in the image.
Figure 15 – Inserting the SFP module
Step 2 After inserting the module, it is necessary to lock it by moving the
bale-clasp latch. This flap also serves to lock the optical cords after
they have been inserted.
Figure 16 – Safety flap
Step 3 After positioning the bale-clasp latch, the optical cords can be
inserted.
Table 9 – Installing SFP/SFP modules
5.2 REMOVING SFP/SFP+ MODULES
Before removing the optical cords, it is recommended that you check if
there are labels on them that indicate in which switch and interface they
should be connected, facilitating their identification later.
204.4314.02 – October/2019 24
DM4370 – Installation Guide Installing and Removing Transceivers
In order to remove the modules, simply follow the same insertion instructions in reverse
order:
Step Description
Step 1 Remove the optical cords
Step 2 Lower the bale-clasp latch
Pull the module by the bale-clasp latch, as shown in the image
Step 3
below.
Figure 17 – Removing the SFP module
Table 10 – Removing the SFP module
When the switch is operating at temperatures above 45°C the user must
use industrial-grade SFP/SFP+ modules. Contact Technical Support if
you have any questions.
204.4314.02 – October/2019 25
DM4370 – Installation Guide Logging in for First Time
6 LOGGING IN FOR FIRST TIME
Considering the equipment correctly installed as described previously, the user can
manage it through a Command Line Interface (CLI). The CLI is accessed by using a
direct console connection or by using a SSH connection from a remote management
terminal.
6.1 CONNECTING BY CONSOLE INTERFACE
You can access the Command Line Interface (CLI) through the local console interface
located on the left side of the switch's front panel; to do so, simply connect a
compatible console cable and run a terminal emulator such as Hyper Terminal or
similar on a desktop or laptop. The DM4370 default setting is baud rate 9600, with 1
stop bit and no parity, as shown in the image below.
Figure 18 – Serial interface configuration on the computer
The DM4370 switch does not support hardware flow control. In the
configuration of the Console Interface the hardware flow control should
be disabled.
On the PC or laptop, start the terminal emulation program.
Step 1 The initial login prompt for a username appears:
login as:
The default username and password are admin. Type the
Step 2 username followed by [Enter]:
login as: admin [Enter]
Type the password followed by [Enter]:
Step 3
Password: admin [Enter]
The prompt as following will appear, indicating a successful
login:
Result
Welcome to the DmOS CLI
DM4370#
Table 11 – DM4370 Login
6.2 CONFIGURING A MANAGEMENT INTERFACE
The configuration below will set up the device management according to the above
diagram. If you are connected by MGMT interface, the session will be disconnected
204.4314.02 – October/2019 26
DM4370 – Installation Guide Logging in for First Time
after the commit. To continue setting the device by MGMT interface, you must set an IP
address on your PC whithin the same network or connect by Console:
Entering the configuration mode:
Step 1
# configure
Entering the configuration MGMT interface:
Step 2
(config)# interface mgmt 1/1/1
Configuring the IPv4 address on the MGMT interface:
Step 3
(config-mgmt-1/1/1)# ipv4 address 172.2.22.1/24
Removing the default IP address (only one is supported) and
exit:
Step 4
(config-mgmt-1/1/1)# no ipv4 address 192.168.0.25/24
(config-mgmt-1/1/1)# top
Configuring the default gateway address and exit configure
mode:
Step 5
(config)# router static address-family ipv4 0.0.0.0/0
next-hop 172.2.22.254
Applying and saving configuration changes:
Step 6
(config)# commit
Table 12 – Configuring Management Interface
See the Quick Configuration Guide for more information about the
switch's management settings.
6.3 DEFAULT ACCOUNT
One account is configured by default on the DM4370: admin.
Account Password Description
admin is an account that has admin level privileges. So, it can
admin admin view and change all device parameters. It is a complete read-
and-write access to the entire device.
Table 13 – Default Account
Due the security reasons, it is strongly recommended to change the
admin account password at the first time login.
204.4314.02 – October/2019 27
DM4370 – Installation Guide Logging in for First Time
6.4 CHANGING DEFAULT ADMINISTRATOR ACCOUNT PASSWORD
For security reasons it is highly recommended to modify the default administrator
account password.
Entering the configuration mode:
Step 1
# configure
Entering the user mode:
Step 2
(config)# aaa user admin
Changing the password:
Step 3
(config-user-admin)# password new-password
Exiting the user mode:
Step 4
(config-user-admin)# exit
Applying and saving configuration changes:
Step 5
(config)# commit
Table 14 – Changing Password
204.4314.02 – October/2019 28
DM4370 – Installation Guide Technical Specification
7 TECHNICAL SPECIFICATION
7.1 INTERFACES
DM4370
Interfaces
4GT+4GX+4XS
Console (RJ45) 1
Management 10/100/1000Base-T
1
(RJ45)
USB Device (tipo mini B) 1
10/100/1000Base-T (RJ45) 4
1000Base-X (SFP) 4
10GBase-X (SFP+) 4
AC/DC power input (IEC 320/C14) 1
12V DC power input (DC JACK) 1
Table 15 – Interfaces do produto
7.2 POWER SUPPLY
7.2.1 AC/DC Power Input (IEC 320/C14 connector)
DM4370
4GT+4GX+4XS
100 a 240 Vac (± 10%)
Rated AC operating voltage
50/60Hz
Rated DC operating voltage -48 to -60 Vdc (± 20%)
Rated AC current 0.25 A
Maximum AC current 0.35 A
Rated DC current 0.80 A
Maximum DC current 0.95 A
Table 16 – AC/DC power input specifications
7.2.2 12V DC Power Input (DC Jack connector)
DM4370
4GT+4GX+4XS
Rated operating voltage 12 Vdc (± 5%)
Rated current 2.00 A
Maximum current 2.50 A
Table 17 – DC power input specifications
7.3 PHYSICAL SPECIFICATIONS
DM4370
4GT+4GX+4XS
Height 43 mm
Width 189 mm
Depth 191 mm
Net weight 1.3 kg
Table 18 – DM4370 physical specifications
204.4314.02 – October/2019 29
DM4370 – Installation Guide Technical Specification
7.4 ENVIRONMENTAL INFORMATION
DM4370
4GT+4GX+4XS
Operating temperature 0°C to 55°C
Operating relative 10% to 90%, non-
humidity condensed
Operating altitude 0 to 3,000m
Storage temperature -20°C to 70°C
Table 19 – DM4370 operating conditions
When the switch is operating at temperatures above 45°C the user must
use industrial-grade SFP/SFP+ modules. Contact Technical Support if
you have any questions.
204.4314.02 – October/2019 30
DM4370 – Installation Guide Standards and Regulations
8 STANDARDS AND REGULATIONS
Class Standard Description
Directive 2014/30/EU Electromagnetic Compatibility
REQUISITOS TÉCNICOS DE COMPATIBILIDADE
ELETROMAGNÉTICA PARA AVALIAÇÃO
EMC Ato 1120
DACONFORMIDADE DE PRODUTOS PARA
TELECOMUNICAÇÕES
Telecommunication network equipment;
ElectroMagnetic Compatibility (EMC) requirements;
ECM ETSI EN 300 386
Harmonised Standard covering the essential
requirements of the Directive 2014/30/EU
Electromagnetic compatibility of multimedia
EMC EN 55032
equipment - Emission requirements
Technical documentation for the assessment of
EMC EN 50581:2012 electrical and electronic products with respect to the
restriction of hazardous substances
Immunity to conducted disturbances, induced by
EMC EN 61000-4-6
radio-frequency fields
EMC EN 61000-4-2 Electrostatic discharge immunity test
EMC EN 61000-4-4 Electrical fast transient/burst immunity test
EMC EN 61000-4-5 Surge immunity test
Radiated, radio-frequency, electromagnetic field
EMC EN 61000-4-3
immunity test
EMC EN 61000-3-2 Limits for harmonic current emissions
Limitation of voltage changes, voltage fluctuations
EMC EN 61000-3-3
and flicker in public low-voltage supply systems
Directive 2014/35/EU Low Voltage
Safety EN 60825-1 Safety of laser products
Information technology equipment – Safety – Part 1:
Safety EN 60950-1
General requirements
Directive 2011/65/EU Restriction of Hazardous Substances in Electrical
and Electronic Equipment (RoHS)
Technical documentation for the assessment of
RoHS EN 50581:2012 electrical and electronic products with respect to the
restriction of hazardous substances
Directive 2012/19/EU Waste Electrical & Electronic Equipment (WEEE)
Environmental Conditions
EN 300 019-1-1, Class
-- Environmental Conditions for storage
1.2
EN 300 019-1-2, Class
-- Environmental Conditions for Transport
2.3
Rua América, 1000 | 92990-000 | Eldorado do Sul | RS | Brazil
+55 51 3933 3000
[email protected] 204.4314.02 – October/2019 31