LMM6000 Laser Settings
Laser Settings for LMM6000 Materials
The following table details recommended laser settings for LMM6000 materials on a range of
common substrates. These settings are designed to help guide the user to the optimum
parameters as quickly as possible. Please note that there will be variations in substrate finish
and between different brands of laser. It may still be necessary to perform further refinement of
settings to achieve the desired mark.
LMM6000 Suggested Laser Settings Used for CO2 X-Y Laser
Settings 45W laser Settings 30W laser
Substrate Material Power Speed Power Speed Lens DPI/PPI
(W) (in/sec) (W) (in/sec)
Stainless Steel 41 98 30 70 2” 1000/1000
Stainless Steel - Bright
45 70 30 63 1.5” 1000/1000
Annealed
Galvanized Steel 45 63 30 49 1.5" 1000/1000
Brass 45 21 30 14 1.5" 1000/1000
Aluminum 45 28 30 21 1.5" 1000/1000
Copper 45 14 30 3 1.5" 1000/1000
Chrome plating 30 21 30 21 2" 1000/1000
Nickel Plating 45 28 30 18 1.5" 1000/1000
Gold Plating 45 21 30 14 1.5" 1000/1000
Silver Plating 45 8 30 3 1.5" 1000/1000
Titanium 29 126 29 126 1.5” 1000/1000
Pewter 41 70 30 50 2" 1000/1000
TherMark Holdings Inc ▪ 33 Hammond ▪ Suite 205 ▪ Irvine, CA 92618
——————————————————————————————————————————
Tel (323) 344 9500 ▪ Fax (949) 861 6211 ▪ www.thermark.com
LMM6000 Laser Settings
Suggested Laser Settings Used for Beam Steered ND:YAG or Fiber Laser with a
100mm lens
Power Speed Hatch CW Mode or Q-Switch
Material
(W) (cm/sec) Spacing “ Freq
Stainless Steel 9 18 .002 CW / ≥50KHz
Stainless Steel -
9 18 .002 CW / ≥50KHz
Bright Annealed
Galvanized Steel 9 20 .002 CW / ≥50KHz
Brass 9 10 .002 CW / ≥50KHz
Aluminum 10 10 .002 CW / ≥50KHz
Chrome plating 10 6 .002 CW / ≥50KHz
Nickel Plating 10 25 .002 CW / ≥50KHz
Gold Plating 10 15 .002 CW / ≥50KHz
Silver Plating 10 3 .002 CW / ≥50KHz
Titanium 7 30 .002 CW / ≥50KHz
Pewter 10 30 .002 CW / ≥50KHz
Page 2 of 2