MCT 10 Software Setup Guide

The document describes the setup of an MCT 10 drive including: - Connected drive information and database details such as the drive series, type, software version, and address. - Parameter groups for operation and display settings, load and motor settings, references and limits, and inputs and outputs. - Specific parameter settings within each group such as the language, reference range, ramp times, input functions, and more.

Uploaded by

peter
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
198 views5 pages

MCT 10 Software Setup Guide

The document describes the setup of an MCT 10 drive including: - Connected drive information and database details such as the drive series, type, software version, and address. - Parameter groups for operation and display settings, load and motor settings, references and limits, and inputs and outputs. - Specific parameter settings within each group such as the language, reference range, ramp times, input functions, and more.

Uploaded by

peter
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

MCT 10 Set-up Software

MCT 10 Set-up Software Project -- buque1 Wednesday, January 14, 2015

Group Folder: Project

Drive Name: 1; VLT 2807 380V-480V


Connected Drive Information Database Information
Drive Series: VLT 2800 VLT 2800
Drive Type: 2807 380V-480V 2807 380V-480V
SW Version: 3.10 3.10
Communication Option: None None
Application Option: 3.0 WOBBLER 3.xx WOBBLER
Drive Address: 1
Driver Name: Serial
Description

Parameter Group: 0-** Operation and display

ID Name Setup 1 Unit


001 Language Español (4)
002 Operation site Remote (0)
003 Local reference 0.000
004 Active setup Setup 1 (1)
006 Setup copy No copy (0)
007 Lcp copy No copy (0)
008 Frequency scale 1.00
009 Display line 2 Frequency [Hz] (4)
010 Display line 1.1 Reference [%] (1)
011 Display line 1.2 Motor current [A] (6)
012 Display line 1.3 Power [kW] (8)
013 Loc ctrl/config. Loc+dig ctrl/as p100 (4)
014 Local stop Enable (1)
015 Local jogging Disable (0)
016 Local reversing Disable (0)
017 Local reset Enable (1)
018 Data change lock Not locked (0)
019 Power up action Local=stop (1)
020 Hand operation Enable (1)
024 User quickmenu Disable (0)
025.1 Quick menu setup 0
025.2 Quick menu setup 0
025.3 Quick menu setup 0
025.4 Quick menu setup 0
025.5 Quick menu setup 0
025.6 Quick menu setup 0
025.7 Quick menu setup 0
025.8 Quick menu setup 0
025.9 Quick menu setup 0
025.10 Quick menu setup 0
025.11 Quick menu setup 0
025.12 Quick menu setup 0
025.13 Quick menu setup 0
025.14 Quick menu setup 0
025.15 Quick menu setup 0
025.16 Quick menu setup 0
025.17 Quick menu setup 0
025.18 Quick menu setup 0
025.19 Quick menu setup 0
025.20 Quick menu setup 0

Parameter Group: 1-** Load and motor

Page: 1 of 5
MCT 10 Set-up Software Project -- buque1 Wednesday, January 14, 2015

ID Name Setup 1 Unit


100 Configuration Speed open loop (0)
101 Torque charact Constant torque (1)
102 Motor power 0.75 kW
103 Motor voltage 440 V
104 Motor frequency 60 Hz
105 Motor current 2.10 A
106 Motor nom. speed 3410 RPM
107 Auto motor tun. Amt off (0)
108 Stator resistan 10.890 Ohm
109 Stator reactance 242.00 Ohm
117 Resonance damp. 0 %
119 High start torq. 0.0 s
120 Start delay 0.0 s
121 Start function Coast/delay time (2)
122 Function at stop Coast (0)
123 Min.f. func.stop 10.0 Hz
126 Dc braking time 10.0 s
127 Dc brake cut-in 0.0 Hz
128 Mot.therm protec Etr trip 1 (4)
130 Start frequency 0.0 Hz
131 Initial voltage 0.0 V
132 Dc brake voltage 0 %
133 Start voltage 18.74 V
134 Load compensatio 100.0 %
135 U/f ratio 6.87
136 Slip comp. 100.0 %
137 Dc hold voltage 0 %
138 Brake cut out 3.0 Hz
139 Brake cut in 3.0 Hz
140 Current min val 0 %
142 Leak. reactance 24.200 Ohm
143 Fan control Automatic (0)
144 Gain ac brake 1.30
146 Reset vector Off (0)

Parameter Group: 2-** References and limits

ID Name Setup 1 Unit


200 Out freq rng/rot 132 hz clock wise (0)
201 Min output freq 20.0 Hz
202 Max output freq 60.0 Hz
203 Reference range Min - max (0)
204 Min. reference 0.000
205 Max. reference 60.000
206 Ramp type Linear (0)
207 Ramp up time 1 3.00 s
208 Ramp down time 1 3.00 s
209 Ramp up time 2 3.00 s
210 Ramp down time 2 3.00 s
211 Jog ramp time 3.00 s
212 Q stop ramp time 3.00 s
213 Jog frequency 10.0 Hz
214 Ref function Sum (0)
215 Preset ref. 1 0.00 %
216 Preset ref. 2 0.00 %
217 Preset ref. 3 0.00 %
218 Preset ref. 4 0.00 %
219 Catch up/slw dwn 0.00 %
221 Current limit 160.0 %
223 Warn. current lo 0.0 A
224 Warn. current hi 2.3 A
225 Warn. freq. low 31.0 Hz

Page: 2 of 5
MCT 10 Set-up Software Project -- buque1 Wednesday, January 14, 2015

226 Warn. freq. high 62.0 Hz


227 Warn. feedb. low -4,000.000
228 Warn. feedb high 4,000.000
229 Freq bypass b.w. 0 Hz
230 Freq. bypass 1 0.0 Hz
231 Freq. bypass 2 0.0 Hz

Parameter Group: 3-** Inputs and outputs

ID Name Setup 1 Unit


302 Digital input 18 Start (7)
303 Digital input 19 No operation (0)
304 Digital input 27 Motor coast inverse (2)
305 Digital input 29 No operation (0)
307 Digital input 33 No operation (0)
308 Ai [V]53 funct Reference (1)
309 Ai 53 scale low 0.0 V
310 Ai 53 scale high 10.0 V
314 Ai [mA]60 funct Reference (1)
315 Ai 60 scale low 0.0 mA
316 Ai 60 scale high 20.0 mA
317 Live zero time o 10.0 s
318 Live zero funct. Off (0)
319 Ao 42 function 0-iinv = 0-20 ma (7)
323 Relay 1-3 funct. Unit ready (1)
327 Pulse ref/fb max 5000 Hz
328 Pulse max 29 5000 Hz
341 Do 46 function Unit ready (1)
342 Do 46 max puls 5000 Hz
343 Precise stop Normal (0)
344 Pulse count pre. 100000
349 Speed comp delay 0 ms

Parameter Group: 4-** Special functions

ID Name Setup 1 Unit


400 Brake function Off (0)
405 Reset mode Manual reset (0)
406 Autorestart time 5 s
409 Trip delay cur. 61 s
411 Switch freq. 4500 Hz
412 Var carrier freq Without lc-filter (2)
413 Overmodulation On (1)
414 Min. feedback 0.000
415 Max. feedback 1,500.000
416 Ref/feedb. unit No unit (0)
417 Speed prop gain 0.010
418 Speed int. time 100.00 ms
419 Speed diff. time 20.00 ms
420 Speed d-gain lim 5.0
421 Speed filt. time 100 ms
423 U1 voltage 400.0 V
424 F1 frequency 50.0 Hz
425 U2 voltage 400.0 V
426 F2 frequency 50.0 Hz
427 U3 voltage 400.0 V
428 F3 frequency 50.0 Hz
437 Proc no/inv ctrl Normal (0)
438 Proc anti windup Enable (1)
439 Proc start value 56.0 Hz
440 Proc. prop. gain 0.01
441 Proc. integr. t. 9,999.99 s

Page: 3 of 5
MCT 10 Set-up Software Project -- buque1 Wednesday, January 14, 2015

442 Proc. diff. time 0.00 s


443 Proc. diff. gain 5.0
444 Proc filter time 0.02 s
445 Flying start Disable (0)
451 Feedforward fact 100 %
452 Pid contr. range 10.0 %
455 Freq. range mon. Enable (1)
456 Brake vol reduce 0 V
457 Mains imbalance Trip (0)
461 Feedback conv. Linear (0)
462 Esl timer 0 s
463 Boost setpoint 100 %
464 Wakeup pressure 0.000
465 Pump min. freq 20.0 Hz
466 Pump max. freq 50.0 Hz
467 Min. pump power 0 W
468 Max. pump power 0 W
469 Nf power comp 1.20
470 Dry run time out 31 s
471 Dry run int time 30.0 min
484 Initial ramp 0.0 s
485 Fill rate 0.000
486 Fill setpoint 0.000

Parameter Group: 5-** Serial communication

ID Name Setup 1 Unit


500 Bus address 1
501 Baudrate 9600 baud (5)
502 Coasting select Logic or (3)
503 Q stop select Logic or (3)
504 Dc brake select Logic or (3)
505 Start select Logic or (3)
506 Reversing select Logic or (3)
507 Setup select Logic or (3)
508 Pres.ref. select Logic or (3)
509 Bus jog 1 freq. 10.0 Hz
510 Bus jog 2 freq. 10.0 Hz
512 Telegram profile Fc protocol (1)
513 Bus timeout time 1 s
514 Bus timeout func Off (0)
560 N2 over.rel.time 65534 s
561 Protocol Fc (0)
570 M.bus par./frame No parity/ 1 stopbit (2)
571 M.bus com.time. 100 ms

Parameter Group: 6-** Technical functions

ID Name Setup 1 Unit


600 Operating hours 4.3 h
601 Running hours 0.4 h
602 Kwh counter 0.0 kWh
603 Power up's 15
604 Over temp's 0
605 Over volt's 0
618 Reset kwh count Do not reset (0)
619 Reset run. hour Do not reset (0)
620 Operation mode Normal operation (0)
621 Drive type VLT 2807 380V-480V
624 Software version V 3.10 / 0.00 / 3.0
625 Lcp version NINGUNO
626 Database ver. ID 2.53

Page: 4 of 5
MCT 10 Set-up Software Project -- buque1 Wednesday, January 14, 2015

627 Power unit db id ID 1.32


628 App. option WOBBLER
630 Com. option NONE
632 Bmc-software id ID 2.06
634 Unit id ID 103.191.196
635 Sw. part no. 195C0045
678 Config ctrl card Standard version (1)

Parameter Group: 7-** Group 7

ID Name Setup 1 Unit


700 Wobb mode Off (0)
702 Delta freq 5.0 Hz
703 Jump freq 0.0 Hz
704 Jump time 1 ms
705 Wobb time 10.0 s
706 Wobb ratio 1.0
707 Random func Fix (0)
708 Random max 10.0
709 Random min 0.1

Alarms :
Date Read Time Read Drive Time Code Alarm Text
None

Warnings :
Date Read Time Read Drive Time Code Warning Text
None

Fault Log :
None