0% found this document useful (0 votes)
285 views1 page

CG Power and Industrial Solutions Limited: LT Motors Division Ahmednagar

This 3 sentence summary provides the key details from the document: This document is a data sheet for a 3 phase induction motor with a rated output of 480 kW, 415V, 2985 RPM, IP55 protection, TEFC enclosure, and 95% efficiency at full load for customer Spares 4U with part number QNMXD90087/800. The motor has a frame size of NG400LX, 2 poles, 50Hz frequency, IC411 cooling, and measures 3500 kg with dimensions of 355LX/400LX.

Uploaded by

Mohan Babu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
285 views1 page

CG Power and Industrial Solutions Limited: LT Motors Division Ahmednagar

This 3 sentence summary provides the key details from the document: This document is a data sheet for a 3 phase induction motor with a rated output of 480 kW, 415V, 2985 RPM, IP55 protection, TEFC enclosure, and 95% efficiency at full load for customer Spares 4U with part number QNMXD90087/800. The motor has a frame size of NG400LX, 2 poles, 50Hz frequency, IC411 cooling, and measures 3500 kg with dimensions of 355LX/400LX.

Uploaded by

Mohan Babu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

CG Power and Industrial Solutions Limited

LT Motors Division
Ahmednagar

DATA SHEET OF 3 PHASE INDUCTION MOTOR


Customer : Spares 4U Enquiry / INDENT NO : QNMXD90087/800 (Dated: 02/09/2019)

Frame NG400LX Rated Output (kW) 480


Voltage (V) 415 +-10% Rated Current (A) 781.00
Rated Speed (RPM) 2985 No of poles 2
Frequency (Hz) 50 +-5% Duty S1
Method of Cooling IC411 Degree of Protection IP55
Gas Group Not applicable Mounting B3
Temp Class NO
Enclosure TEFC Safe Area

Load 100% Load 75% Load 50% Load


Efficiency IE2 - 95 % 94.5 % 93 %
Power factor 0.90 0.88 0.84
AMB. Temp/Temp rise 50°C/95°C (By Resistance Method)
Insulation class F (Temp. rise limited to class ‘F’)
Rated Torque (kg-m) 156.62
Locked rotor current % FLC 700
Starting torque % FLT 125
Pull out torque % FLT 200

Method of starting Variable Voltage / Frequency


Winding connections Delta
No of terminals 6
Direction of rotation Bidirectional

Motor GD Sq. (kg-m²) 53.46


Load GD Sq. (kg-m²) 53.46
Starting time @100% V (Sec) 5.7
Locked rotor Withstand time hot (Sec.) 15
Locked rotor Withstand time cold (Sec.) 30
Stator Thermal / Cooling time constant 60 / 120
(min)
Terminal box position Slant at 45°RHS(355LX/400LX)
Cable size 2 * 3C,400-MM²
Bearing DE/ODE 6318-C4 / 6318-C4 I
Type of lubrication Unirex-N3
Shaft Material EN8 OR C40 Stator Body Material #N/A

Net Weight (Approx.) kg 3500


Paint shade RAL7034
Applicable standards IS:1231,IS:12075,IS:12065,IS:325,
Space heaters N.A
Accessories Rod Type Btd Reqd(1/Brg),Insulated Bearing At Nde,3Wire Type Rtd
Pt100-3Nos Reqd,Space Heater 100Wx4 (400),

Customer specific requirement if any:

All performance data is subject to tolerance as per IEC 60034


All performance shall be measured on sinusoidal supply
Temp rise test shall be carried at rated kW & voltage for 1 hour other than S1 duty
Max 5 % THD allowed for voltage and Temperature rise is limited to class F, unless otherwise specified
Inverter driven motors, voltage spikes are allowed maximum 1600 V
with min. rise time of 0.1 microsecond, cable size to be selected accordingly.
Customer specific paint shade and paint thickness will not be applicable on powder coated components.
Issued By : Vinoth Kumar M
Date : 02/11/2019 LT Motors Division, Ahmadnagar

Page 1 of 1