TSV Valve Specifications and Calculations

This document provides specifications for a TSV-inlet MP separator including: - Physical properties of the trapped fluid and flow parameters - Pressure settings for the separator and relief valve - Calculated values for the required relief valve discharge area and standard valve size

Uploaded by

Aymen Khlifi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
883 views3 pages

TSV Valve Specifications and Calculations

This document provides specifications for a TSV-inlet MP separator including: - Physical properties of the trapped fluid and flow parameters - Pressure settings for the separator and relief valve - Calculated values for the required relief valve discharge area and standard valve size

Uploaded by

Aymen Khlifi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

TSV-inlet MP separator

Specific heat of the trapped flui, C (Btu/lb °F) 0.698 Total heat transfer rate (Btu/h) 227445.49
Cubical expansion coefficient, B (1/°F) 0.0009 Flow rate (l/min) 7.208
Radiation solaire (W/m²) 1040 Reynold’s Number, R 124176.13
Set pressure, PS (kPag) 9300 Percent of Gauge Backpressure, (PB/PS) (%) 0.00
Back pressure, PB=P1 (kpag) 0 Correction factor due to back pressure, KW 1.00
Specific gravity 0.308 Combination correction factor, KC 1.00
Absolute viscosity, (cP) 0.397 Correction factor due to viscosity, KV 1.00
Rupture disk Not installed Relieving pressure, P1 (kPag) 10230.00
Overpressure Pe r cen t
10 of Ga uge B ack Pr es s ur e (PB/PS)*1 00

Kv for no viscosity correction 1 Required effective discharge area, AR (mm2) 0.72


Rated coefficient of discharge, Kd 0.65 Required effective discharge area, A (in2) 0.00111
Diamétre (in) 16 Standard effective discharge area, A (in2) 0.11
Longueur (m) P e rce
100
n t o f Ga
Type of PRV
u ge Ba ck P r essu r e ( P B/P
DS) *1 00

Size of PRV 1D2


PRV-Inlet MP separator

Specific heat of the trapped flui, C (Btu/lb °F) 0.698 Total heat transfer rate (Btu/h) 227445.49
Cubical expansion coefficient, B (1/°F) 0.0009 Flow rate (l/min) 7.208
Radiation solaire (W/m²) 1040 Reynold’s Number, R 124176.13
Set pressure, PS (kPag) 9300 Percent of Gauge Backpressure, (PB/PS) (%) 0.00
Back pressure, PB=P1 (kpag) 0 Correction factor due to back pressure, KW 1.00
Specific gravity 0.308 Combination correction factor, KC 1.00
Absolute viscosity, (cP) 0.397 Correction factor due to viscosity, KV 1.00
Rupture disk Not installed Relieving pressure, P1 (kPag) 10230.00
Overpressure Pe r cen t
10 of Ga uge B ack Pr es s ur e (PB/PS)*1 00

Kv for no viscosity correction 1 Required effective discharge area, AR (mm2) 0.72


Rated coefficient of discharge, Kd 0.65 Required effective discharge area, A (in2) 0.00111
Diamétre (in) 16 Standard effective discharge area, A (in2) 0.11
Longueur (m) P e rce
100
n t o f Ga
Type of PRV
u ge Ba ck P r essu r e ( P B/P
DS) *1 00

Size of PRV 1D2