Metallized Polypropylene Film Capacitors (MKP)
Metallized Polypropylene Film Capacitors (MKP)
© TDK Electronics AG 2020. Reproduction, publication and dissemination of this publication, enclosures hereto
and the information contained therein without TDK Electronics' prior express consent is prohibited.
Metallized polypropylene film capacitors (MKP) B32671L, B32672L
High V AC, high temperature (wound)
Climatic
Max. operating temperature: 125 °C
Climatic category (IEC 60068-1:2013):
55/110/56
Construction
Dimensions in mm
Dielectric: metallized polypropylene (PP)
Wound capacitor technology
Lead spacing Lead diameter Type
Plastic case (UL 94 V-0)
±0.4 d1 ±0.05
Epoxy resin sealing
10 0.6 B32671L
Features 15 0.8 B32672L
Very high AC voltages for all frequency
ranges
Very small dimensions
High peak voltage for short time periods
High peak current
High pulse withstand capability
RoHS-compatible
Halogen-free capacitors available on request
AEC-Q200D compliant
Terminals
Parallel wire leads, lead-free tinned
Special lead lengths available on request
Marking
Manufacturer's logo
lot number, series number
Rated capacitance (coded)
Capacitance tolerance (code letter)
Rated voltage
Date of manufacture (coded)
Delivery mode
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping, refer to chapter "Taping and packing“.
Lead spacing 10 mm 15 mm
Type B32671L B32672L
Page 4 6
VRMS (V AC) 200 250 250 500 600 700 160 200 250 250 500 600 700 900
VR (V DC) 400 630 1000 1000 1600 2000 250 450 630 1000 1300 1600 2000 2000
CR (nF)
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
15
22
33
47
56
68
100
150
220
330
390
470
680
1000
Technical data
Reference standard: IEC 60384-16:2005 and AEC-Q200D. All data given at T = 20 °C, unless
otherwise specified.
Rated temperature TR +85 °C
Operating temperature Max. operating temperature Top,max +125 °C
range Upper category temperature Tmax +110 °C
Lower category temperature Tmin 55 °C
Rated temperature TR +85 °C
Dissipation factor tan δ at ≤27 nF 27 nF< CR ≤0.1 μF 0.1 μF < CR ≤1 μF >1 μF
(in 10-3) at 20 °C 1 kHz 0.8 0.8 0.8 0.8
(upper limit values) 10 kHz 1.0 1.0 1.0
100 kHz 2.0 3.0
Insulation resistance Rins 100 GΩ (CR ≤ 0.33 μF)
or time constant 30000 s (CR > 0.33 μF)
τ = CR Rins at 20 °C,
rel. humidity ≤ 65%
(minimum as-delivered
values)
DC test voltage 1.6 VR, 2 s
Category voltage VC Top (°C) DC voltage derating AC voltage derating
(continuous operation Top ≤ 85 VC = VR VC,RMS = VRMS
with VDC or VAC at f ≤1 kHz) 85<Top≤110 VC = VR (165Top)/80 VC,RMS=VRMS (165Top)/80
Operating voltage Vop for Top (°C) DC voltage (max. hours) AC voltage (max. hours)
short operating periods Top ≤ 100 Vop = 1.25 VC (2000 h) Vop = 1.0 VC,RMS (2000 h)
(VDC or VAC at f ≤1 kHz) 100<Top≤125 Vop = 1.25 VC (1000 h) Vop = 1.0 VC,RMS (1000 h)
Biased humidity 1000 h / 40 °C / 93% relative humidity with VR,DC
Limit values after test Capacitance change ΔC/C ≤ 5%
Dissipation factor change Δ tan δ ≤ 0.002 (at 1 kHz)
Insulation resistance Rins ≥ 200 MΩ
Reliability:
Failure rate λ 1 fit (≤ 1 10-9/h) at 0.5 VR, 40 °C
Service life tSL 200 000 h at 1.0 VR, 85 °C
For conversion to other operating conditions and temperatures, refer
to chapter "Quality, 2 Reliability".
Failure criteria:
Total failure Short circuit or open circuit
Failure due to variation Capacitance change ΔC/C > 10%
of parameters Dissipation factor tan δ > 4 upper limit values
Insulation resistance Rins < 1500 MΩ
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/μs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/μs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor. These parameters are given for isolated pulses in such a way that the heat generated
by one pulse will be completely dissipated before applying the next pulse. For a train of pulses,
please refer to the curves of permissible AC voltage-current versus frequency.
dV/dt values
Lead spacing 10 mm
Type B32671L
VRMS (V AC) 200 250 500 600 700
VR (V DC) 400 630 1000 1000 1600 2000
CR (nF) dV/dt in V/μs
1.0 11000
1.2 6000 10000
1.5 5600 9500
2.2 5200 9000
2.7 5000 8600
3.3 4700 4700 8500
3.9 4300 4500 8200
4.7 810 3800 4000 8000
5.6 3400
6.2 3200
6.8 810 3100
8.2 2700
10 810 2500
12 2300
15 540 810
22 400 540 810
33 400 540
47 400 540
56 540
68 400
100 400
dV/dt values
Lead spacing 15 mm
Type B32672L
VRMS (V AC) 160 200 250 500 600 700 900
VR (V DC) 250 450 630 1000 1300 1600 2000 2000
CR (nF) dV/dt in V/μs
1.0 10000 15000
1.2 9400 14100
1.5 9000 13500
2.2 7500 11000
2.7 7100 10600
3.3 6800 10000
3.9 6000 9000
4.7 5500 8200
5.6 5000 7500
6.2 3600 4700 7000
6.8 1000 3500 4500 6700
8.2 3100 4200
10 445 1000 2800 3900
12 2600 3600
15 445 2300 3300
22 445 1000 2000 2900
33 300 445 1000 1700 2300
47 300 445 1000 1400
56
68 200 300 445 1000
100 200 300 445
150 170 200 300 445
220 170 200 300
330 170 200
390 300
470 170 200
680 170 200
1000 170
k0 values
Lead spacing 10 mm
Type B32671L
VRMS (V AC) 200 250 500 600 700
VR (V DC) 400 630 1000 1000 1600 2000
CR (nF) k0 in V2/μs
1.0 25000000
1.2 14400000 23000000
1.5 14000000 22500000
2.2 13800000 22000000
2.7 13600000 21500000
3.3 9400000 13300000 21000000
3.9 8600000 13100000 20900000
4.7 400000 8200000 12000000 20800000
5.6 7600000
6.2 6800000
6.8 400000 6200000
8.2 5400000
10 400000 5000000
12 4600000
15 200000 400000
22 150000 200000 400000
33 150000 200000
47 150000 200000
56 200000
68 150000
100 150000
k0 values
Lead spacing 15 mm
Type B32672L
VRMS (V AC) 160 200 250 500 600 700 900
VR (V DC) 250 450 630 1000 1300 1600 2000 2000
CR (nF) k0 in V2/μs
1.0 20300000 30000000
1.2 19600000 29400000
1.5 19200000 28000000
2.2 18600000 27500000
2.7 18200000 27300000
3.3 18000000 27000000
3.9 16800000 25200000
4.7 15800000 23500000
5.6 13100000 19500000
6.2 11520000 12700000 19000000
6.8 3000000 11200000 12300000 18400000
8.2 9920000 11800000
10 1000000 3000000 8960000 11100000
12 8320000 10600000
15 1000000 7360000 10400000
22 1000000 3000000 6400000 9300000
33 500000 1000000 3000000 5440000 9000000
47 500000 1000000 3000000 4480000
56
68 120000 500000 1000000 3000000
100 120000 500000 1000000
150 100000 120000 500000 1000000
220 100000 120000 500000
330 100000 120000
390 500000
470 100000 120000
680 100000
1000 100000
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
400 V DC/200 V AC 630 V DC/250 V AC
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
1600 V DC/600 V AC 2000 V DC/700 V AC
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
250 V DC/160 V AC 450 V DC/200 V AC
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
1300 V DC/500 V AC 1600 V DC/600 V AC
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
400 V DC/200 V AC 630 V DC/250 V AC
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
1600 V DC/600 V AC 2000 V DC/700 V AC
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
250 V DC/160 V AC 450 V DC/200 V AC
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
1300 V DC/500 V AC 1600 V DC/600 V AC
Maximum AC voltage (VRMS), current (IRMS) versus frequency and temperature for TA >100 °C
The graphs described in the previous section for the permissible AC voltage (VRMS) or current
(IRMS) versus frequency are given for a maximum ambient temperature TA ≤100 ºC. In case of
higher ambient temperatures (TA), the self-heating (ΔT) of the component must be reduced to
avoid that temperature of the component (Top= TA + ΔT) reaches values above maximum
operating [Link] factor FT shall be applied in the following way:
Operation at overvoltages during heating and ignition of lamps (TA ≤40 °C)
In lighting applications, the capacitors can be subjected to overvoltages during the heating and ig-
nition periods. An overvoltage occurs when the operating voltage exceeds the permissible
AC voltage at the resonant frequency fr.
For a repetitive application of on/off switching pulses (as for example in the life tests applied by
electronic ballast manufacturers), limits have to be imposed on the time periods under overvolt-
age and on the duty cycle, in order to keep the capacitance value within the required margins:
The K0 calculated in the overvoltage period (see general technical information) shall be lower
than the maximum K0 provided.
The maximum duty cycle of the overvoltage is given by
and VRMS is the permissible AC voltage for continuous operation at the resonant frequency fr
(given by the “permissible AC voltage versus frequency f” graphics in theprevious pages).
The drift of capacitance depends on the Vpp attained, and the total time under overvoltage,
which is calculated in hours as follows:
(Ni tOV) / 3600
where Ni is the number of overvoltage impulses and tOV is expressed in seconds.
The maximum drift of capacitance as a function of both parameters is provided graphically in the
following pages.
Estimation of the maximum drift of capacitance value in function of the number of total
hours overvoltage
Lead spacing 10 mm
500 V AC/1000 V DC 600 V AC/1600 V DC
Estimation of the maximum drift of capacitance value in function of the number of total
hours overvoltage
Lead spacing 15 mm
600 V AC/1600 V DC 700 V AC/2000 V DC
Mounting guidelines
1 Soldering
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far
higher than the upper category temperature of the capacitors, the terminal wires should be cut off
from the capacitor before the ageing procedure to prevent the solderability being impaired by the
products of any capacitor decomposition that might occur.
The overheating associated with some of these factors can usually be reduced by suitable coun-
termeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced
cooling process may possibly have to be included.
Recommendations
As a reference, the recommended wave soldering profile for our film capacitors is as follows:
The table below summarizes the safety instructions that must always be observed. A detailed
description can be found in the relevant sections of the chapters "General technical information"
and "Mounting guidelines".
&RUUHODWLRQRIGDWDVKHHWYDOXHVDQGPRGHOOLQJWRRORXWSXWV
'DWDVKHHWYDOXHVDQGUHVXOWVRIGHVLJQWRROVPD\GHYLDWHDVWKH\KDYHQRWEHHQGHULYHGLQWKH
VDPHFRQWH[W
:KLOH GDWD VKHHWV VKRZ LQGLYLGXDO SDUDPHWHU VWDWHPHQWV ZLWKRXW FRQVLGHULQJ D SRVVLEOH GHSHQ
GHQF\WRRWKHUSDUDPHWHUV7RROVPRGHODFRPSOHWHJLYHQVFHQDULRDVLQSXWDQGSURFHVVHGLQVLGH
WKHWRRO
)XUWKHUPRUHDVZHFRQVWDQWO\VWULYHWRLPSURYHRXUPRGHOVWKHUHVXOWVRIWRROVFDQFKDQJHRYHU
WLPHDQGEHDQRQELQGLQJLQGLFDWLRQRQO\
Page 38 of 39
Important notes
7. Our manufacturing sites serving the automotive business apply the IATF 16949 stan-
dard. The IATF certifications confirm our compliance with requirements regarding the quality
management system in the automotive industry. Referring to customer requirements and cus-
tomer specific requirements (“CSR”) TDK always has and will continue to have the policy of
respecting individual agreements. Even if IATF 16949 may appear to support the acceptance
of unilateral requirements, we hereby like to emphasize that only requirements mutually
agreed upon can and will be implemented in our Quality Management System. For clari-
fication purposes we like to point out that obligations from IATF 16949 shall only become
legally binding if individually agreed upon.
8. The trade names EPCOS, CarXield, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas,
CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue,
MiniCell, MKD, MKK, ModCap, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap,
PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID,
SineFormer, SIOV, ThermoFuse, WindCap, XieldCap are trademarks registered or pend-
ing in Europe and in other countries. Further information will be found on the Internet at
[Link]/trademarks.
Release 2020-06