LINEAR 7.5Fr.
IAB Catheter
This document is intended to provide information to an international audience outside of the US.
The LINEAR 7.5Fr. Catheter
Easier to insert*
Proprietary IAB Membrane provides better performance*
• Abrasion resistance improved 43%*
• Improved fatigue resistance*
• Immediate inflation at start-up*
• Reduced insertion force* Insertion force reduced by 43%*
1.10
Abrasion resistance* in different membranes
1.00
4.5 .90
4 .80
3.5 0
.70
3 .60
LBS
2.5 .50
%
2 .40
1.5 .30
1 .20
0.5 .10
0 0
LINEAR 7.5Fr. Competitor LINEAR Competitor
Proprietary IAB Cardiothane™ II 7.5Fr. 7.5Fr.
Membrane
The smaller 7.5Fr. size is ideal for small adults, diabetics,
Artery Lumen
and patients with PVD*
8Fr. Increased space for
• Reduced catheter cross section area by 12% vs. 8Fr.*
distal flow
• Smaller catheter size allows increased distal limb flow
• Minimize the size of arterial puncture
LINEAR
• Ease of insertion in smaller or diseased vessel lumens (Drawing not 7.5Fr.
to scale) Catheter
•L
INEAR IAB catheter has 43% reduction in insertion forces
compared to Competitor 7.5Fr. IAB catheter*
We weren’t satisfied to make it smaller
We had to make it better
Smaller profile without compromised performance*
• F
aster gas shuttle performance allows better support of LINEAR 7.5Fr. Displayed faster cycle time*
rapid heart rates and arrhythmias 600
• LINEAR has 19% faster cycle time in 80º bend test method
compared to competitive IAB catheters* 500
Improved sheath 400
Cycle Time (msec)
• Improved sheath to introducer transition
• Hemostasis valve 300
• Twist lock introducer hub
• Universal color coding for size 200 Deflation
• Wire reinforced sheath
Inflation
100
0
Old design LINEAR 7.5Fr. Competitor
introducer transition
LINEAR 7.5Fr. features “T-Handle” protector for balloon membrane
improved sheath-to-
introducer transition • Keeps the membrane tightly wrapped prior to insertion
• Helps to handle catheter prior to insertion
“T-Handle” protector
simplifies handling of
catheter
Twist lock introducer
hub prevents accidental
separation
Technical Specifications*
LINEAR 7.5Fr. IAB Catheter with Insertion Kit
Balloon
Item Number Nominal Nominal Balloon Dia. at Insertable Pressure Lumen ID Guidewire
Volume (cc) Length (mm) 2 psi (mm) Length (mm) Size (in.) Size (in.)
0684-00-0480-01 40 258 15.0 723 0.027 0.025
0684-00-0479-01 34 221 15.0 723 0.027 0.025
0684-00-0478-01 25 165 15.0 723 0.027 0.025
Ordering Information Configuration
Description Item Number Materials
40cc LINEAR 7.5Fr. IAB Catheter with Catheter Extender 0684-00-0480-01 All balloon and catheter materials meet
FDA and ISO biocompatibility guidelines
40cc LINEAR 7.5Fr. IAB Catheter with Arrow Pump Adapter 0684-00-0480-02 for devices and materials. LINEAR 7.5Fr.
IAB catheters and insertion kits do not
34cc LINEAR 7.5Fr. IAB Catheter with Catheter Extender 0684-00-0479-01 contain latex.
34cc LINEAR 7.5Fr. IAB Catheter with Arrow Pump Adapter 0684-00-0479-02 Packaging
25cc LINEAR 7.5Fr. IAB Catheter with Catheter Extender 0684-00-0478-01 Single Pouch, Corner Peel
25cc LINEAR 7.5Fr. IAB Catheter with Arrow Pump Adapter 0684-00-0478-02 Cycle Life
40cc and 34cc Insertion Kit includes: 0884-00-0019-13 1 procedure
6" (15cm) Reinforced Sheath Introducer with hemostasis valve
and Introducer Dilator Shelf Life
One 18 gauge Angiographic Needle, One Vessel Dilator
One 0.025" X 145cm 3mm J PTFE Stainless Steel Guidewire 3 years from date of sterilization
One 6 ft. Catheter Extender (40cc and 34cc only) All parameters specified at 25°C ambient
One Male Luer Cap temperature. Maquet maintains a policy
One Three-Way Stopcock of continual product improvement and
Two 4 ft. (122cm) Pressure Tubings reserves the right to change materials and
specifications without notice.
25cc Insertion Kit includes:
0884-00-0019-12
Above contents and One 5 ft. Catheter Extender
0.025" X 145cm 3mm J PTFE Stainless Steel Guidewire (Box of 5) 0684-00-0254-09
0.025" X 175cm 3mm J PTFE Stainless Steel Guidewire (Box of 5) 0684-00-0254-14
0.025" X 260cm 3mm J PTFE Stainless Steel Guidewire (Box of 5) 0684-00-0254-15
Arrow Pump Adapter 5PK (25cc to 40cc) 0684-00-0510-01
7.5Fr. Sheath and Dilator Set 0684-00-0403-05
Catheter Extender for 40cc and 34cc IABs only (Box of 10) 0684-00-0186
Catheter Extender for 25cc only (Box of 10) 0684-00-0335
*Data on file
Maquet offers a range of convenient and innovative Maquet created a Proprietary IAB Membrane so it can stand
clinical solutions for counterpulsation therapy, such as up to your most difficult patients. It’s stronger, more durable,
our LINEAR 7.5Fr. intra-aortic balloon catheter product line. yet thinner than any previous IAB membrane. Our Proprietary
We weren’t satisfied to make a smaller shaft catheter, we also IAB Membrane patented blow-molded polyurethane material
had to make it perform better than the competition and our has been developed to withstand the constant abrasion of
previous product lines. even the most calcified aortas. Yet it is so thin, it allows us to
make far less invasive catheters.
Getinge Group. Passion for life.
PN: 0002-08-0598 Rev C · Getinge Group Passion for Life, Getinge Group, Getinge, ArjoHuntleigh and Maquet are trademarks or registered trademarks of Getinge AB, its subsidiaries, or affiliates in the United States or other countries.
Getinge Getinge Group, ArjoHuntleigh and Maquet are registered with the U.S. Patent and Trademark Office · Copyright 2016 Datascope Corp. · All rights reserved · 07/2016
Maquet
1300 MacArthur Blvd., Mahwah, NJ 07430, USA
Phone: +1 201 995 8700
www.getingegroup.com
Getinge Group is a leading global provider of innovative solutions for
operating rooms, intensive-care units, hospital wards, sterilization
departments, elderly care and for life science companies and institu-
tions. With a genuine passion for life we build quality and safety into
every system. Our unique value proposition mirrors the continuum
of care, enhancing efficiency throughout the clinical pathway. Based
on our first-hand experience and close partnerships, we are able to
exceed expectations from customers – improving the every-day life
for people, today and tomorrow.
This document is intended to provide information to an international audience outside of the US.