Underground
Underground
: 29040-PI-UPS-1010
PIPING STUDY
Rev. : R0
UNDERGROUND PIPING
Uhde India Limited Page : 1
CONTENTS
Page
List of illustrations 2
1.0 General 3
Applicable Revision:
Prepared: Checked: Approved:
LIST OF ILLUSTRATIONS
14 UGP14 INDICATIVE PFD FOR OWS , CRWS ( NOTES FOR DWG. NO.
UGP13 )
15 UGP15 G.A.FOR UNDERGROUND PIPING (DETAILS)
1.0 GENERAL
1.1 The piping system is taken underground generally for the utility services like cooling water
supply to various units and cooling water return to cooling tower for line sizes normally above
18 inch NB, other water services with big pipeline sizes, big oil supply lines and various
sewer systems in the process units of the chemical, petrochemical and refinery type of
plants. The term "underground" applies to the piping - both buried or in trenches. The
underground system consist of gravity flow drainage system carrying process waste,
spillage, reclaimable hydrocarbons, sanitary and storm water, firewater and drinking water
system.
1.2 Good engineering practice, local code / regulations, specific client requirements shall govern
the design of the underground piping system in the plant.
1.3 The following are the common underground services in a chemical / petrochemical / refinery
plants.
- Cooling water (line size normally =18" NB)
- Fire Water
- Contaminated water sewer from process catchment area.(CRWS)
- Oily water sewer (OWS)
- Liquid Effluent to the Effluent Treatment Plant.
- Closed Blow down system (CBD)
- Sanitary system
- Storm Water
- Equipment drainage to slop tank
- Electrical cables
- Instrument cables
Oily water sewer shall collect oily waste / drain from pump, equipments through funnel
points and shall run with separate headers and manholes in the units. The regular oil
contamination areas shall also be segregated and discharge from these areas shall be
collected in catch basins to be joined in oily water sewer. Oily water sewer shall consist of
carbon steel sewer, funnel points, clean outs, RCC catch basins, RCC manholes, vent
pipes, flame arrestor etc.
2.3 Contaminated Rainwater Sewer (CRWS)
The areas which are contaminated due to floor wash drains etc. inside unit boundaries shall
be demarcated. Contaminated areas collected in catch basin shall be drained through
CRWS while un-contaminated areas, normally at periphery of the units shall be drained
through ditches covered with grating.
CRWS shall consist of undergound carbon steel sewer with corrosion protection, funnel
points, clean outs, RCC catch basins, RCC manholes, vent pipes, flame arrestor etc.
Open ditches of units should have a bypass either to the CRWS or to storm water, drains of
offsite.
This system collects surface drainage from areas containing hydrocarbon - bearing
equipment. This water must pass through a treatment facility before being discharged into
an uncontaminated system or natural body of water e.g. river or a stream.
2.4 Closed Blow Down (CBD) sewer
This system picks up drains around boilers and steam drums and is run as a separate
system preferrably to the battery limit.
The system shall be designed as per P&ID and the effluent collected from equipments
through funnel points and underground piping system shall be connected to the underground
CBD drum.
2.5 Amine Blow Down (ABD) sewer
The amine blow down system (ABD) shall be designed as per P&ID.
The effluent shall be collected from equipments through above ground points into close
funnels connected to underground system. The main header shall be connected to the
underground Amine sump / drum.
2.6 Fire Water Sytem
This system consists of a fire hydrant network around a process unit or equipment, with
branches as required for hydrants or monitors to protect the unit in case of fire.
This is a close loop system starting from Firewater storage and pump to the specific
location of hydrants and monitors. This is always kept under a predetermined working
pressure level.
2.7 Potable Water System
This water is used for drinking, emergency eye washes and safety shower facilities.
2.8 Sanitary Sewer System
Sanitary sewer system collects waste from all toilet facilities provided in various plants and
non-plant buildings and shall be discharged to WWTP (Waste Water Treatment Plant)
Acids, caustics, hydrocarbons, rainwater or other chemical waste shall not be discharged to
this system.
This system is routed to normally to a septic tank.
TRAINING MANUAL- PIPING DOC No. : 29040-PI-UPS-1010
PIPING STUDY
Rev. : R0
UNDERGROUND PIPING
Uhde India Limited Page : 5
system / drainage system with varying wall thickness, it is the constant that is used to set
the elevation on construction drawings.
The starting invert level of CRWS shall be normally 750mm below HPP (High Point of
Paving)
The invert level at outlet point of CRWS and OWS shall be normally 1500mm below FGL.
3.4 Cleanout
A cleanout is a piping connection in a sewer system that is located at grade level for
inspections or for cleaning the system.
3.5 Vent Pipes
Vent pipes shall be located along piperack columns or building columns and should be
taken 2m above the building parapet or last layer of pipes on a piperack.
3.6 Valve Pit / Maintenance pit for flanges and instruments.
When the underground system needs valves for isolation and instruments for control, the
normal practice is to enclose these valves and instruments in a RCC pit with cover. These
valves and instruments in a pit can be operated as well as maintenance work can be done
with ease.
4.10 The underground electrical and instrument cables passing under a road or paved area is
taken through ducts embeded in lean concrete. Sketch UGP23 shows a typical
arrangement of such underground cabling details.
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP1
CATCH BASIN
CATCH BASIN
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP2
UNPAVED AREA
SLOPE OF
UNPAVED AREA
(TYP.)
PAVED AREA
WEST BATTERY LIMIT
PAVED AREA
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP3
PAVED AREA
WEST BATTERY LIMIT
CLOSE
DRAIN
ELECTRICAL SYSTEM
DUCT EXHIBIT
MH
CATCH
BASIN
PAVED AREA
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP4
PUMP
PUMP PUMP
GRADE
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP5
PAVED AREA
WEST BATTERY LIMIT
PAVED AREA
UNPAVED AREA
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP6
3/4"
4"/.100
DRAIN HUB
(REDUCER)
COLLECTION HEADER
TO SUMP (SIZED BY
PROCESS ENGINEERS)
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP7
103-J 104-L
SUMP PUMP SUMP
4"/.100
TOP EL.
FGL GRADE
SIZED BY CIVIL ENGINEERS
0.250-3"-CIA
BOTTOM EL.94'-9"
WORKING POINT
CL EL. 97'-9"
PLAIN END
CL EL. 96'-0"
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP8
CW
HW
CL EL.98'-0
WEST BATTERY LIMIT
CW CL EL.98'-9" CL EL.98'-0
HW CW
HW
CL EL.97'-0
CL EL.98'-0
HOT WATER RETURN (HW)
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP9
PLAN
45°
45°
ELEVATION
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP10
CL EXCHANGER
UNDERGROUND UNDERGROUND
PIPING PIPING
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP11
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP12
FOOT PEDAL
DRAIN
SHOWER HEAD
CLOSED
POSITION
STAY OPEN
BALL VALVE
(TYP.)
OPEN
POSITION
EYE WASH
CLOSED
OPEN
DRAIN
FOOT PEDAL
ABOVE
GRADE
UNDER-
GROUND
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP13
NOZZLE
HANDLE
MONITOR
HYDRANT
CL FIRE HOSE
CONNECTIONS
GUARD POST
9"/.230
GRADE
BUFFALO
BOX
GUARD
POST
SUPPORT
(BY CIVIL
ENGINEER)
45°
P.) BLOCK
(TY VALVE
0
FIRE HOSE
90
3'/.
CONNECTIONS
MONITOR
CL HYDRANT
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP14
NOZZLE
HANDLE
VENDOR
DRAIN VALVE
CONTRACTOR
1200 ABOVE GRADE
CL VALVE
(4'-0")
(2'-0")
600
6"/.150
GRADE
1800 SQUARE
(6'-0")
ALTERNATIVE SUPPORT
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP15
CONDUIT TO
OTHER USERS
ELECTRICAL
PULL BOX
CL HIGH POINT
PAVING
EL. 100-1"
SIZED BY
ELECTRICAL
ENGINEERS ELECTRICAL CONDUIT
ENCASED IN LEAN
CONCRETE
ELEVATION BY PLANT
LAYOUT DESIGNER
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP16
TRENCH PIPING
CL DRAIN
TANK
A A
B 1/4 B B
GRATING INV.EL.97'-11"
COVER
1/8 B
6"CI
INV.EL.97'8" CONCRETE
1/8 B COVER
CATCH INV.EL.97'-2"
BASIN
PLAN
AS REQUIRED
GRATING CONCRETE
LINE "B" COVER COVER
EL. 100'-0"
1/2"/.015
1/4 B
INV.EL.97'-11"
SECTION "A-A" (INV.=INVERT)
SECTION "B-B"
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP17
4" VENT TO
ATMOSPHERE
(CARBON STEEL)
8"/.200
6"/.150
CL OUTLET
1/8 BEND
SUPPORT
INSIDE BOTTOM
ELEVATION
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP18
STORAGE TANK
SLOPE
A
SLOPE
DYKE SUMP
A
DRAIN LINE
PLAN
INSIDE DYKE
EXTENSION STEM
PLATFORM
BUFFALO BOX
SUMP
GRADE
DRAIN LINE
VALVE USUALLY
CLOSED
SECTION `A-A'
TRAINING MANUAL - PIPING DOC NO. : 29040-PI-UPS-1010
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP19
LIFT STATION
VERTICAL PUMP
ACCESS
HATCH
DISCHARGE LINE
LADDER
RUNGS
1/8 BEND
CAST IRON
CAPACITY SIZED BY
SYSTEMS ENGINEERS
: 29040-PI-UPS-1010
: R0
UNDERGROUND PIPING :1
: UGP20
1 2
10
100 (NPS 4)
0(
S=
10
NP
100 (NPS 4)
0(N
S4
OF 4-150 (NPS 6)
PS
)
39PC-103A
4)
(TYP)
CO
PS
CL. 39DM-101
4)
100 (NPS 4)
APRON
39PC-104 CL.
10
S= 100 (NPS 4)
DF3-150(NPS 6) CO
PS
4)
CO
CL.
S=
CL K2 PS-104 3 5
39PC-105A 2
CL.
10
HP.
0
(N
PS
39 1919 KC-100 (NPS 4) 100 (NPS 4)
4)
IL
CO
CL. S=
IL (NP K2 PS-119
OP
39VL-102 9 CO S4 CL.
)
E
MATCH LINE S ---- DRG. K2-A1-5105
S4
CL. IL )
NP
100 (NPS 4)
0(
10
S=
39 1932 KC-100 (NPS 4)
CL. K2-CB- 39 1902 KC-200 (NPS 8)
W= 3-108 39DM-105 5
* SUBLATERAL
4)
CL.
IL
PS
39 1918 KC-100 (NPS 4)
(N
HP.
100 (NPS 4)
0
CO S= K2-PS-102 10 CO
100 (NPS 4)
CL.
* BRANCH
CO
S=
CL.
CL.
BOTTOM OF TRENCH HP.
CL. PS COLS
EL.
S=
K2 PS-118
39 1930 KC-100 (NPS 4)
4)
1 LATERAL * CL.
S
NP
39 VL-101
CL. * LATERAL SUBLATERAL
CL.
CO
0(
CL.
10
100 (NPS 4)
100 (NPS4)
19
(TYP)
11
CL. K2-PS-101 IL 8
39-PC-101B 8
ELECTRICAL TRENCH
CL. CO CO
IL
39 1911 KC-200(NPS 8) K2 CB-3-107 39 1928 KC-100 (NPS 4) CO
100 (NPS 4) OF 4-150 (NPS 6)
39 1916 KC-100 (NPS 4)
S= W= S=
39 1917 KC-100 (NPS 4) 19
4 1 IL 5 100 (NPS 4) 100 (NPS 4)
ELECTRICAL TRENCH
S=
CO
HP
100 (NPS 4) CO 10 1
39FT-101A 39FT-101B
39-PC-101A CL.
CL.
IL * SUBLATERAL
HP
11 NOTES:-
1. FOR GENERAL NOTES LEGEND AND DETAILS SEE DRAWINGS STDD-00-A1-5003 &
STDD-00-A1-5004
12 2. ALL CHANGES OF DIRECTION AND ELEVATION IN SEWER SYSTEMS SHALL BE MADE WITH 1/8
(45°) BENDS AND/OR 45° PLAIN JUNCTIONS EXCEPT AS NOTED OR SHOWN OTHERWISE ON
PLAN OR DETAIL DRAWINGS.
15 3. UNLESS NOTED OTHERWISE ALL DRAIN FUNNELS
SHOWN ARE DF-1
SHOWN ARE DF-2
15
4. UNLESS NOTED OTHERWISE ALL CLEANOUTS ARE CO-1.
7 5. UNLESS NOTED OTHERWISE TOP OF ALL CATCH BASIN SHALL BE AT EL.
6. UNLESS NOTED OTHERWISE EACH BRANCH RUN SHALL START AT AN INVERT LEVEL (IL) OF AT
THE UPPERMOST DRAIN FUNNEL WHERE THE SLOPE IS NOT INDICATED IN STALL THE LINE WITH A
UNIFORM SLOPE BETWEEN SPECIFIED INVERT LEVELS (ELEVATIONS)
13 7. UNLESS NOTED OTHERWISE ALL UNDERGROUND STEEL LINES WITH AN ABOVE GROUND CONTINUATION
SHALL TERMINATE 300 ABOVE HIGH POINT OF FINISHED SURFACE
16 8. JOINTS AND/OR WELDS ON UNDERGROUND PRESSURE SYSTEMS
SHALL BE LEFT EXPOSED UNTIL THE LINE HAS BEEN
HYDROSTATICALLY TESTED PER SP-50-9 K2-A1-5103
16 9. FOR THE TESTING OF UNDERGROUND GRAVITY SEWER A. AREA AND UNIT NUMBER. K2-A1-5101
K2-A1-5104
SYSTEMS SEE SP-00-11.
B. SHEET NUMBER TO CORRESPOND WITH THE THIS
10. ALL LINES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH LAST TWO DIGITS OF THE DRAWING NUMBER K2-A1-5105 DRAWING
THIS DRAWING ISOMETRIC DRAWINGS OF THE FOLLOWING LINES
ONLY HAVE BEEN PREPARED TO ASSIST IN INSTALLATION. C. DRAWING NUMBERS SHALL BE INDICATED KEY PLAN
ON EACH INDIVIDUAL BILL OF MATERIAL.
11. FOR PIPING MATERIAL OF LINES NOT ON ISOMETRIC REFER TO 16
THE PIPING BILL OF MATERIAL OF THE APPLICABLE LINE NO.
12. UNLESS NOTED OTHERWISE ALL DRAIN FUNNELS WILL BE
LOCATED PER STANDARD DRG. STDD-00-A1-5003.
13. UNLESS NOTED OTHERWISE ALL NPS 4 LINES SHALL SLOPE AT 0.016.
14. UNLESS NOTED OTHERWISE ALL NPS 6 LINES SHALL SLOPE AT 0.013. * DIMENSIONS IN mm. UNLESS OTHERWISE STATED.
: 29040-PI-UPS-1010
: R0
UNDERGROUND PIPING :1
: UGP21
PURPOSE : 10 ELEVATIONS
SHALL BE REQUIRED BY CONSTRUCTION HAS BEEN PROVIDED ADDITIONAL 11 SEWER LINE SLOPES
1 CO-ORDINATES
12 FITTINGS
CO-ORDINATES SHALL BE GIVEN FOR MATCH LINES, CENTRE LINES OF
MAIN HEADERS, MANHOLES AND CATCH BASINS FOUNDATION CENTRE LINES IDENTIFY THE PREDOMINANT TYPES OF FITTINGS BY THE USE OF A NOTE
ARE NOT CO-ORDINATED BUT ARE USED AS REFERENCE LINES FOR EXCEPTIONS OR ROUTING THAT REQUIRES CLEARIFICATION SHALL BE
ALL MATCH LINE CO-ORDINATES AND DRAWING NUMBERS SHALL BE WHERE PIPING IS CONTINUED ABOVE GROUND NOTE THE METHOD OF THE
PLACED OUT SIDE OF THE MATCH LINES ALL MATCH LINES SHALL CARRY TERMINATING UNDER GROUND STUB-UPS EXCEPTIONS TO THE NOTE
DRAWING CONTINUATION NUMBERS WHEN THERE IS NOT AN ADJACENT SHALL BE CALLED OUT ON THE DRAWING SHOW ABOVE GROUND LINE
DRAWING TO REFER TO THE UNDER GROUND PIPING DRAWING INDEX NUMBER. NUMBERS ON THE DRAWING.
PORTIONS OF FOUNDATIONS THAT ARE LOCATED BELOW GROUND SHALL GIVE SUFFICIENT PLAN DIMENSIONS TO LOCATE ALL CHANGES OF
BE SHOWN TO CORRECT SCALE. DIRECTION AND ELEVATION NOT COVERED BY A CO-ORDINATE.
PROPER CALLED OUT ON THE DRAWING.
4 ELECTRICAL TRENCHES AND PIPE TRENCHES
BE SHOWN TO SCALE CLEARANCE WITH ADJACENT PIPING SHALL BE IDENTIFY THE DETAILS USED PREDOMINANTLY BY THE USE OF A NOTE
CAREFULLY CHECKED. EXCEPTIONS TO THE NOTE SHALL BE IDENTIFIED BY A PROPER CALL OUT
ON THE DRAWING.
5 PAVING
LIMITS OF PAVED AREAS HIGH POINTS AND VALLEYS SHALL BE SHOWN IN 16 PRESSURE TEST DATA
7 PAVING OR FINISHED SURFACE ELEVATIONS (eg. NOTES 1 TO 9 ) ALL OTHER PLANS WITH IN THAT AREA SHALL
NOTE IT SHALL BE SHOWN ON THE DRAWING. SHOW A KEY PLAN ON EACH UNDERGROUND PIPING PLAN.
8 LINE NUMBERS
19 PIPE AND FITTING SIZES
LINE NUMBERS ARE GIVEN FOR ALL PRINCIPLE HEADERS, SEWER MAINS, NOMINAL SIZES FOR STEEL PIPE AND FITTINGS SHALL BE GIVEN IN INCHES
LATERALS AND SUBLATERALS AND FOR BRANCHES CONNECTING DIRECTLY NOMINAL SIZES FOR PIPE AND FITTING OTHER THAN STEEL (eg. VITRIFIED
TO CATCH BASINS AND/OR MANHOLES. CLAY AND CONCRETE) SHALL BE GIVEN IN MM.
9 SYSTEM IDENTIFICATION
20 PIPING BILLS OF MATERIAL
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP22
DWF
DIA.
SCOPE
SLOPE SLOPE
VELOCITY
DIA. DIA.
FUNNEL POINT TOTAL FLOW
FLOW FLOW (TYP.)
NOTE-6 & 16
NOTE-6 NOTE-6 (TYP.)
UNCONTAMINATED AREA
MANHOLE
NOTE-5
REFER
NOTE-14
REFER
NOTE-4
SEALED MANHOLE
CATCHPIT
HPP FGL
6.05 5.75
CONTAMINATED
AREA
TWO WAY
CATCHMENT HOG GRATING NC VALVE PIT
AREA 150SQ.M. UNCONTAMINATED AREA
(TYP.) NO
TO STORM
WATER
STORM WATER DRAIN DRAIN
FOR COLLECTION OF
SURFACE DRAINAGE FROM
UNCONTAMINATED AREAS
LEGENDS
DWG - DRY WEATHER FLOW
WWF - WET WEATHER FLOW
NC - NORMALLY CLOSE
NO - NORMALLY OPEN
Rev. : R0
PIPING STUDY
Uhde India Limited UNDERGROUND PIPING Page :1
DWG. NO. : UGP23
NOTES :
1. THE PFD IS FOR CONTRACTORS REFERENCE ONLY.
11. ALTHOUGH VENT PIPES NOT SHOWN HERE, HOWEVER ALL SEALED
MANHOLES SHALL HAVE VENT PIPES AS PER DESIGN BASIS.
A. PROCESS FLOW
B. DIA. OF PIPE
C. SLOPE
D. VELOCITY
16. INVERT LEVEL AT OUTLET POINT OF CRWS & OWS SHALL BE 1500MM BELOW FGL.