Introduction
UTStarcom University
Customer Training Center
UT斯达康内部资料 1
Module Objectives
UT斯达康内部资料 2
Module Topics
• System Components.
• Main Shelf Cabling.
• Shelf Architecture
• Common Modules.
• Application Modules.
• MSAP Module Installation Rules.
• Initial Configuration.
UT斯达康内部资料 3
System Components
UT斯达康内部资料 4
iAN8K B1000 Overview
UT斯达康内部资料 5
iAN8K B1000 Hardware Platforms
UT斯达康内部资料 6
RA – 10U Shelf
• 19 slots
• Module slots - front-access.
• Adapter slots - rear-access.
• 3 thermally controlled Fan
Tray.
• External Splitters only.
• Air Flow: Up to rear.
• MSAN or IPDSLAM.
– Without rear splitters.
UT斯达康内部资料 7
RA – 10U Shelf
-48v -48V NU NU NU NU
-48V -48V NU NU
RTN RTN GND GND
A B A B
UT斯达康内部资料 8
RA+ – 12U Shelf
• 19 slots.
• Module Slots - front-access.
• Adapter Slots - rear-access.
• 3 Thermally controlled Fan
Trays.
• Rear-pluggable Splitters
supported.
• Air flow: Up to rear.
• Normally used for
IPDSLAM.
– Rear splitters available.
UT斯达康内部资料 9
FA – 16U Shelf
UT斯达康内部资料 10
Shelf Front View
Fans • Slot P.
– For power modules only.
• Slot 1 and 2.
– Used to install ICM3 modules (if DSL
modules installed).
– Can be used to install other user
modules if no ICM3 required.
• Slot 3-16 (Universal Slots).
– Used to install xDSL, POTS, VPM,
TDM, EOE or RTM-S modules.
– ICM3 module not supported.
• Slot 17 and 18.
– SCM4 module in the main shelf.
– EBAM3 module in extension shelves.
UT斯达康内部资料 11
Shelf Rear View
• Slot P.
– MCU-A module in the main shelf.
– PRM2-RA adapter in the extension
shelf.
• Slot 1-2.
– ICM3-RA adapter if ICM3 present.
– Rear module corresponding adapters if
no ICM3.
• Slot 3-16.
– Rear module corresponding adapters.
• Slots 17-18.
– SCM4-RA in main shelf.
– EBAM3-RA in extension shelves.
CPM
UT斯达康内部资料 12
Fan Trays
UT斯达康内部资料 13
Shelf Remarks
UT斯达康内部资料 14
B1000 Multi-chassis Configuration
PDP
PSS
UT斯达康内部资料 15
B1000 RA Chassis Shelf ID
DIP Switches
Ext Shelf 1
• In a system with more than one
chassis, each shelf must have a
different and unique Shelf ID
within the node. Ext Shelf 2
UT斯达康内部资料 16
Power Distribution
To backplane
PDP
300R&F
CPM 2
PRM2
-48V IN 2 -48V IN 2
Ring/5V
UT斯达康内部资料 17
iAN8K B1000 PDP300R
UT斯达康内部资料 18
iAN8K B1000 PDP300R
-48V -48V
Output Output
1A-6A 1B-6B Fan Alarm
UT斯达康内部资料 19
iAN8K B1000 PDP300F
UT斯达康内部资料 20
iAN8K B1000 PDP300F
UT斯达康内部资料 21
iAN8K B1000 PDP300R/F
ON: Normal.
OFF: No input, or input power The LED indicates
Power B connection is reversed. status of Power
Green
LED Flash: (at interval of 0.3s): Input A.
Abnormal input power, either too
high or too low.
UT斯达康内部资料 22
iAN8K B1000 PDP300R/F
UT斯达康内部资料 23
iAN8K B1000 CPM2
RING
RTN RING GND +5V
-48V -48V
RTN -48V CMC2 RTN -48V
UT斯达康内部资料 24
Main Shelf Cabling
UT斯达康内部资料 25
Extension Shelves Cabling
Ext Shelf 3
• Intra-shelf cabling. EBAM-RA
– INTERCON.
• Sends clock, control and
communication signals. Ext Shelf 2
EBAM-RA
• Inter-shelf cabling.
– RS485A / RS485B.
• Cascaded. Main Shelf
• Sends clock, control, and SCM4-RA
communication signals.
– BLVDS.
• Star topology from SCM4-RA.
• Sends TDM bus signals.
Ext Shelf 1
EBAM-RA
UT斯达康内部资料 26
SCM4A-RA/EBAM3-RA Cable Routing
UT斯达康内部资料 27
Shelf Fan Alarm Cables
UT斯达康内部资料 28
Phone Line Test Cabling
4 4
Ring in 3 3
Tip in 2 2
1 1
UT斯达康内部资料 29
Clock Connections
UT斯达康内部资料 30
NMS Connections
UT斯达康内部资料 31
Shelf Architecture
UT斯达康内部资料 32
iAN8K B1000 Bus Architecture
NMS
MCU
Serial
Clock
TDM
Test
UT斯达康内部资料 33
iAN8K B1000 TDM Internal Buses
UT斯达康内部资料 34
iAN8K B1000 Ethernet Bus
1 x GE
UT斯达康内部资料 35
iAN8K B1000 Bus Architecture
(POTS)
POTS + IP
STM-1 E1 POTS + xDSL Ethernet N/W Netman 4000
ADSL
Call Agent
S FE/GE
TDM Bus
FE
S I FE
D E P I I FE SS MCU
F I V FE
T 1E x P C FE CC
XF V I PV FE
- M1 DX M MM
SX DV MP FE
1 LM S D SD 3 4 4
M FE
2 L LS
L External
Clock
Main Shelf
TDM Bus
FE
I FE
P I I EE
F I V FE
x P C BB
XF V I
DX PV FE
SX DV MP FE
M AA
S D SD M FE 3 MM
LS
L FE
Extension Shelf
UT斯达康内部资料 36
Common Modules
UT斯达康内部资料 37
iAN8K B1000 Common Modules
Module Module
Adapter Name Description
Type Name
UT斯达康内部资料 38
System Control Module (SCM4)
Ü
UT斯达康内部资料 39
System Control Module (SCM4)
UT斯达康内部资料 40
System Control Module (SCM4)
• TSI – 8k x 8k.
• HDLC Channels – 256.
• SDRAM – 256MB.
• Stores system firmware and configuration
parameters.
• Provides software downloads to slave modules.
• Contains SNMP based network management
interface to Netman and serves as SNMP agent
for the iAN8K B1000.
• Controls up to three slave shelves via the
EBAM3 modules.
UT斯达康内部资料 41
SCM4 Faceplate - LEDS
UT斯达康内部资料 43
SCM4 Faceplate – COM3
RJ45
DB9
COMM
ALIVE Twisted Pair
ACT
ALARM
Cable
Line Connections
RJ45 DB9
1 1
RJ45
2 2
Pin 8 3 3
4 4
Pin 1 5 5
6 6
7 7
8 8
9
UT斯达康内部资料 44
SCM4 1:1 Redundancy (RD)
• Forced switchover.
– Command switchover – CLI or NMS reset/switch command.
– Manual switchover – Switch button or module removal.
• Automatic switchover.
– Detection of hardware failure of active SCM4 within 10 ms.
• Effects.
– Established calls are not interrupted.
– New calls can be established in less than 2 seconds after the
switch over.
– Switch over event reports to NMS with date/time stamp.
UT斯达康内部资料 45
SCM4 1:1 RD/Switchover Control
UT斯达康内部资料 46
SCM4 1:1 Redundancy
UT斯达康内部资料 47
SCM4A-RA Adapter
UT斯达康内部资料 48
SCM4A-RA Faceplate - Connectors
UT斯达康内部资料 49
Expansion Bus Adapter Mod (EBAM3)
UT斯达康内部资料 50
EBAM3 Faceplate - LEDS
Ü
UT斯达康内部资料 51
EBAM3 Faceplate - LEDS
UT斯达康内部资料 52
EBAM3 Redundancy
UT斯达康内部资料 53
EBAM3A-RA Adapter
UT斯达康内部资料 54
EBAM3A-RA Faceplate - Connectors
UT斯达康内部资料 55
E1ML Module
UT斯达康内部资料 56
E1ML Faceplate - LEDS
UT斯达康内部资料 57
PRM2/PRMRD2 Modules
UT斯达康内部资料 58
PRM2/PRMRD2 Faceplate - LEDS
UT斯达康内部资料 59
PRM2B/PRMRD2B Modules
UT斯达康内部资料 60
PRM2B/PRMRD2B Faceplate - LEDS
UT斯达康内部资料 61
Main Control Unit (MCUA-RA) Adapter
UT斯达康内部资料 62
MCUA-RA Faceplate - LEDS
UT斯达康内部资料 63
MCUA-RA Faceplate - Connectors
UT斯达康内部资料 64
PRM2A-RA Adapter
UT斯达康内部资料 65
PRM2A-RA Faceplate - Connectors
Cable
Interface Type Description
Type
10/100
TEST 1 RJ45
Base-T
Used for test bus.
10/100
TEST 2 RJ45
Base-T
Connects to the ALMIN
10/100 port in the MCUA-RA
ALARM RJ45
Base-T module, sends fan and
power alarms.
UT斯达康内部资料 66
Application Modules
UT斯达康内部资料 67
MSAN Modules (1/3)
Module Module
Adapter Name Description
Type Name
The remote user module provides 48 POTS
FXS9 GLS48B-RA
subscriber connections.
UT斯达康内部资料 68
MSAP Modules (2/3)
Module
Module Type Description
Name Adapter Name
The ADSL user module
AD48x-RA(B)
IPADSL6A/B provides 48 ADSL user
IPxDSL User x=A,B,C,D
connections.
Interface Module
The [Link] user module
IPSHDSL3 HSL24B-RA provides 24 [Link] user
connections.
Combines IPADSL3A and
IVD User Interface
IVD-24BT IVD-24A-RA FXS-24BT modules with built-
Module
in splitters.
UT斯达康内部资料 69
MSAP Modules (3/3)
Module
Module Type Adapter Name Description
Name
OAM Module for the MSAN.
Controls management, alarms,
statistics, handles software an
SCM4 SCM4A-RA
firmware for other cards and
communicates with extension
shelves.
Common
Module in the extension shelf
Modules
which connects to SCM4 for
EMAB3 EBAM3-FA
shelf management, traffic
management, timing.
UT斯达康内部资料 70
MSAN Module Installation Rules
UT斯达康内部资料 71
Module Installation Rules
Slot Virtual
Module Assignment Shelf Assignment Notes
CT RT Supporting
BRI Front Front Main/ Yes • When the BRI is installed in slots 2-15, the FXS24BT,
2–15 2–15 Extension FXS24P4, FXS24P4T, E&M3 or FXO3 cannot be installed in
the slots 1 and 16.
• When the BRI is installed in slots 2, the IPADSL3A, IVD, ICM3
cannot be installed in the shelf.
E1ML Front Front Main/ Yes • E1ML is a eight ports module with long haul E1.
1–17 1–17 Extension • Up to 25 E1ML modules for a single node.
SDT12 Front Front Main Yes • Only one SDT12 board can be installed in a node.
1–17 1–17
FXO Front Front Main/ No • When the BRI is installed in slots 2-15, the FXO cannot
1–16 1–16 Extension be installed in the slots 1 and 16.
• When the ICM3 is installed in slots 2, the FXO cannot be
installed in the shelf.
UT斯达康内部资料
Ü 72
Module Installation Rules
Slot Virtual
Module Assignment Shelf Assignment Notes
CT RT Supporting
RTM-S Front Front Main/ No • Only one RTM-S module can be installed per node.
1-17 1-17 Extension
PRM2 Front Front Main/ No
P P Extension
PRMRD2 Front Front Main/ No
P P Extension
VPM Front Front Main/ Yes • Up to four VPM modules can be installed in a single
3–17 3–17 Extension node.
• When an ICM3 is installed in the shelf, do not connect
the Ethernet port in the VPM module to other switch
devices.
UT斯达康内部资料
Ü
73
Module Installation Rules
Slot Virtual
Module Assignment Shelf Assignment Notes
CT RT Supporting
ICM3 Front Front Main/ No • When the FXS (except FXS24BT), E&M or FXO is
1, 2 1, 2 Extension installed in slot 1, the ICM3 cannot be installed in slot 2 at
the same time.
IPSHDSL3 Front Front Main/ Yes • When the BRI or FXO3 is installed in slot 2, the IPSHDSL3
3–16 3–16 Extension cannot be installed in the shelf.
IPADSL6A Front Front Main/ Yes • When the BRI, E&M3, FXO3 , is installed in slot 2, the
3–16 3–16 Extension IPADSL6A/IPADSL6B cannot be installed in the shelf.
SCM4 Front Front Main Yes • One (active) or two (standby) can be installed.
17,18 17,18 • Recommended to plug in Slot 17 first:
• Software recognizes SCM4 slot 17 as active in default.
• Slot 17 has better venting state than Slot 18.
EBAM3 Front Front Extension No • Must be installed in the extension shelf to connect with the
17,18 17,18 main and other extension shelves.
• When two SCM4 are installed in the main shelf, there must be
two EBAM3 in each extension shelf.
SHTM Front Front Main/ Yes • Up to ten SHTM modules can be installed in a single
1–17 1–17 Extension node. Only first 4 ports of 10th SHTM can be used.
UT斯达康内部资料 74
Initial Configuration
UT斯达康内部资料 75
SCM4 Ports
UT斯达康内部资料 76
SCM4 Serial Port
PC
COM Port
9-Pin
RS-232 Cable
UT斯达康内部资料 77
Console To SCM4
SCM4 >
Set ethernet port address
SCM4 > setaddr eth1 [Link] [Link]
SCM4> routed: ignore RTM_ADD without gateway
routed: IP_DROP_MEMBERSHIP ALLROUTERS:
routed: IP_ADD_MEMBERSHIP ALLROUTERS: Address already in use
routed: setsockopt(IP_ADD_MEMBERSHIP RIP): Address already in use
routed: write(rt_sock) RTM_ADD [Link]/24 --> [Link]: File exists
SCM4 > rtadd [Link] [Link] [Link] Set IP default gateway
writing to routing socketadd net [Link]: gateway [Link]: File exists
routed: receiving our own change messages
SCM4 > sipcfg Save ethernet settings
Saving /flash/[Link]
SCM4 > exit
UT斯达康内部资料 78
B1000 Initial Configuration
UT斯达康内部资料 79
Node Basic: System Information
UT斯达康内部资料 80
Node Basic: IP Addresses
• Node IP Addr.
– Active/Standby SCM4s.
– Subnet Mask.
• Default Gateway Addr.
• PPP Interface Peer Addr.
– Address assigned to PPP
peer (computer).
• Signaling IP Addr.
• Trap Destination IP
Address (SNMP).
• Time Server Addr.
• RIP Setup.
– Management information
routing protocol.
UT斯达康内部资料 81
Node Basic: Route Information
UT斯达康内部资料 82
Node Basic: Clock Source
UT斯达康内部资料 83
Save Configuration
• Program and
configuration
synchronization
between SCM4s in a
Dual SCM4
environment is not
done automatically
by default.
• Auto Flash Sync
enables automatic
synchronization
between Active and
Stand-by SCM4.
UT斯达康内部资料 85
Module Review
UT斯达康内部资料
Ü
86
Module Review
UT斯达康内部资料
Ü
87
Module Review
UT斯达康内部资料
Ü
88