This document provides an overview of the hardware components and shelf architecture of the iAN8K B1000 system. It describes the different shelf types (RA, RA+, FA, CX), module slots, fan trays, shelf IDs, power distribution, and the PDP300R power module. The objectives are to identify the shelf components, busses, common modules, application modules, and module installation rules.

Uploaded by

Nasser Mohammed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
248 views88 pages

IAN8K B1000 Hardware

This document provides an overview of the hardware components and shelf architecture of the iAN8K B1000 system. It describes the different shelf types (RA, RA+, FA, CX), module slots, fan trays, shelf IDs, power distribution, and the PDP300R power module. The objectives are to identify the shelf components, busses, common modules, application modules, and module installation rules.

Uploaded by

Nasser Mohammed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

IAN8K B1000 Hardware

Introduction

UTStarcom University
Customer Training Center

UT斯达康内部资料 1
Module Objectives

• Identify shelf types.


• Identify shelf busses and capacities.
• Identify common modules and their position in a shelf.
• List all application specific modules and their adapters.

UT斯达康内部资料 2
Module Topics

• System Components.
• Main Shelf Cabling.
• Shelf Architecture
• Common Modules.
• Application Modules.
• MSAP Module Installation Rules.
• Initial Configuration.

UT斯达康内部资料 3
System Components

UT斯达康内部资料 4
iAN8K B1000 Overview

• Common platform introduction.


– Starting with Release 3.x, the iAN8K B1000 shelf is a common
platform for both MSAN and IPDSLAM applications.
– In MSAN Release 3.3.0, there are software and some hardware
differences between iAN8K B1000 MSAN and iAN8K B1000
IPDSLAM.
– This course covers iAN8K B1000 MSAN installation and
configuration only.

UT斯达康内部资料 5
iAN8K B1000 Hardware Platforms

iAN8K B1000 RA iAN8K B1000 RA+ iAN8K B1000 FA iAN8K B1000 CX


• 19” wide rack mount • 19” wide rack mount • 19” wide rack mount • 19” wide rack mount
• 10 RU height • 12 RU height • 16 RU height • 5 RU height
• 2 slots each for • 2 slots each for • 2 slots each for • 2 slots each for
redundant L2 and redundant L2 and redundant L2 and redundant L2 and
controller module controller module controller modules controller module
• 16 universal slots for line • 16 universal slots for line • 16 universal slots for line • 5 universal slots for line
cards cards cards cards
• External splitters; Telco- • Rear pluggable • Front pluggable • External splitter shelf;
50 connectors for I/O Integrated splitters; Integrated splitters; SCSI-100 connectors for
Telco-50 connectors for SCSI-100 connectors for I/O
I/O I/O
• Redundant –48VDC input • Redundant –48VDC input • Redundant –48VDC input • Redundant –48VDC input
• CE, VCCI compliance • CE, VCCI compliance • CE, VCCI compliance • CE and VCCI compliance
• Application: MSAN, • Application: IPDSLAM, • Application: MSAN • Application: IPDSLAM
IPDSLAM* MSAN*

UT斯达康内部资料 6
RA – 10U Shelf

• 19 slots
• Module slots - front-access.
• Adapter slots - rear-access.
• 3 thermally controlled Fan
Tray.
• External Splitters only.
• Air Flow: Up to rear.
• MSAN or IPDSLAM.
– Without rear splitters.

UT斯达康内部资料 7
RA – 10U Shelf

• 19 slots in the rear shelf.


• DIP Switch – shelf ID.
• Shelf grounding.
• ESD grounding jack.
• Power connection
terminal.

-48v -48V NU NU NU NU
-48V -48V NU NU
RTN RTN GND GND

A B A B
UT斯达康内部资料 8
RA+ – 12U Shelf

• 19 slots.
• Module Slots - front-access.
• Adapter Slots - rear-access.
• 3 Thermally controlled Fan
Trays.
• Rear-pluggable Splitters
supported.
• Air flow: Up to rear.
• Normally used for
IPDSLAM.
– Rear splitters available.

UT斯达康内部资料 9
FA – 16U Shelf

• 19 Module slots and 19


Adapter slots.
– Module slots - Front-access.
– Adapter slots - Front-access.
• 19" rack-mountable.
• Support for SCM4/ICM3
redundancy.
• Aluminum assembled chassis.
• Normally used for MSAN.

UT斯达康内部资料 10
Shelf Front View

Fans • Slot P.
– For power modules only.
• Slot 1 and 2.
– Used to install ICM3 modules (if DSL
modules installed).
– Can be used to install other user
modules if no ICM3 required.
• Slot 3-16 (Universal Slots).
– Used to install xDSL, POTS, VPM,
TDM, EOE or RTM-S modules.
– ICM3 module not supported.
• Slot 17 and 18.
– SCM4 module in the main shelf.
– EBAM3 module in extension shelves.

UT斯达康内部资料 11
Shelf Rear View

• Slot P.
– MCU-A module in the main shelf.
– PRM2-RA adapter in the extension
shelf.
• Slot 1-2.
– ICM3-RA adapter if ICM3 present.
– Rear module corresponding adapters if
no ICM3.
• Slot 3-16.
– Rear module corresponding adapters.
• Slots 17-18.
– SCM4-RA in main shelf.
– EBAM3-RA in extension shelves.

CPM
UT斯达康内部资料 12
Fan Trays

• Each chassis has 3 Fan Trays.


• Each Fan Tray has 2 Fans.
• Fan tray provides LED indicators on
faceplate.
Run
• Temperature control. Alarm
• Provide alarm output.

Name Color Function Status Description


Run Green Indicate power On Normal input power
supply status Off Abnormal input power
Alarm Red Indicate fan On LED lights when one of
tray working following faults occurs:
status - Any fan malfunctions
- Fuse protection failure
- Abnormal input power
Off Fan tray works normally

UT斯达康内部资料 13
Shelf Remarks

• An iAN8K B1000 node may have more than one shelf.


• A shelf can be configured as a:
– Main shelf.
– Expansion shelf.
• Depending on the software and its application, a node
can be configured as:
– RT (remote terminal).
– CT (central Terminal).

UT斯达康内部资料 14
B1000 Multi-chassis Configuration
PDP

• One iAN8K B1000 Node may consist of:


– One Main (Control) shelf. Ext: 1
• Where all transport modules are located.
• Where all the management and TDM
cross-connections take place.
Ext: 2
– Max. 3 Extension shelves (no control
processors).
• Used for increasing the physical capacity
Main
of the node, but not the logical capacity. Shelf
• Mainly used for user modules.
– Special modules and cabling required for
linking together Main Shelf with the Extension
Ext: 3
Shelves.

PSS
UT斯达康内部资料 15
B1000 RA Chassis Shelf ID

DIP Switches

Ext Shelf 1
• In a system with more than one
chassis, each shelf must have a
different and unique Shelf ID
within the node. Ext Shelf 2

• A typical iAN8K B1000


configuration has 1 Main shelf
and 3 Extension shelves. Main Shelf

• Shelf ID configuration is done


by DIP switches on the chassis
rear. Ext Shelf 3

UT斯达康内部资料 16
Power Distribution

To backplane

-48V IN 1 -48V IN 1 -48V

PDP
300R&F
CPM 2
PRM2

-48V IN 2 -48V IN 2

Ring/5V

UT斯达康内部资料 17
iAN8K B1000 PDP300R

• Used with RA and RA+ shelves.


• 2U height.
• 2 independent inputs (200 Amp each).
• 6 redundant outputs.
• Circuit breakers.
• Visual and audio reflexion of system / rack alarms.

UT斯达康内部资料 18
iAN8K B1000 PDP300R

-48V -48V
Output Output
1A-6A 1B-6B Fan Alarm

-48V -48V -48V FGND PDP300R Alarm


Input A Return Input B

UT斯达康内部资料 19
iAN8K B1000 PDP300F

• Uses with FA+ shelf.


• 3U height.
• 2 independent inputs (150 Amp each).
• 6 redundant outputs.
• Circuit breakers.
• Visual and audio reflexion of system / rack alarms.

UT斯达康内部资料 20
iAN8K B1000 PDP300F

UT斯达康内部资料 21
iAN8K B1000 PDP300R/F

Indicators Color Status Description


ON: Normal.
OFF: No input, or input power The LED indicates
Power A connection is reversed. status of Power
Green
LED Flash: (at interval of 0.3s): Input A.
Abnormal input power, either too
high or too low.

ON: Normal.
OFF: No input, or input power The LED indicates
Power B connection is reversed. status of Power
Green
LED Flash: (at interval of 0.3s): Input A.
Abnormal input power, either too
high or too low.

UT斯达康内部资料 22
iAN8K B1000 PDP300R/F

Indicators Color Status Description


ON:
Input power connection is Power input polarity is
Reversed. reversed.
System
Red Indicates rack equipment Other alarms are
Alarm LED
alarm. received from the MCU.
OFF: Normal.

Circuit ON: Circuit breaker alarm. Individual circuit breaker


Breaker Yellow OFF: Normal. monitoring can be enabled
Alarm LED or disabled via SW1/SW2
on the PDP’s.

MUTE / Push: Mutes the audible When pressed all LEDs


- alarm and tests the front turn ON and the audible
TEST
panel LEDs. alarms are cleared.

UT斯达康内部资料 23
iAN8K B1000 CPM2

RING
RTN RING GND +5V
-48V -48V
RTN -48V CMC2 RTN -48V

UT斯达康内部资料 24
Main Shelf Cabling

UT斯达康内部资料 25
Extension Shelves Cabling
Ext Shelf 3
• Intra-shelf cabling. EBAM-RA

– INTERCON.
• Sends clock, control and
communication signals. Ext Shelf 2
EBAM-RA
• Inter-shelf cabling.
– RS485A / RS485B.
• Cascaded. Main Shelf
• Sends clock, control, and SCM4-RA
communication signals.
– BLVDS.
• Star topology from SCM4-RA.
• Sends TDM bus signals.
Ext Shelf 1
EBAM-RA

UT斯达康内部资料 26
SCM4A-RA/EBAM3-RA Cable Routing

Slot 17 Slot 18 Slot 18


Extension Shelf 1 Extension Shelf 1

Extension Shelf 2 Extension Shelf 2

Main Shelf Main Shelf

Extension Shelf 3 Extension Shelf 3

UT斯达康内部资料 27
Shelf Fan Alarm Cables

• The MCU receives alarm messages from the shelf fan


tray and sends them to the SCM4 module through an
RJ45 interface.

UT斯达康内部资料 28
Phone Line Test Cabling

RJ11 Pin assignment


2 4 1 3
1 3 2 4

4 4
Ring in 3 3
Tip in 2 2
1 1

UT斯达康内部资料 29
Clock Connections

• Provide dual clock redundancy access (bypass).


– Bypass two redundancy clock inputs to SCM4.

RJ45 Pin Signal Direction Description

EXTTA Input External clock input +


EXTRA Input External clock input -

• CLK IN1 - RJ45 - Connects to external clock source.


• CLK IN2 - RJ45 - Connects to the second external
clock source.

UT斯达康内部资料 30
NMS Connections

• NMS 1 - RJ45 - 10/100 Base-T.


– Connects the active SCM4 to the NMS to enable the
communication between iAN8K B1000 and the NMS.
• NMS 2 - RJ45 - 10/100 Base-T.
– Connects the active SCM4 to the NMS for redundancy.

RJ45 Pin Signal Direction Description


RD+ Input Receive Data +
RD1 Input Receive Data -
TD+ Output Transmit Data +

TD- Output Transmit Data 1

UT斯达康内部资料 31
Shelf Architecture

UT斯达康内部资料 32
iAN8K B1000 Bus Architecture

NMS

MCU

Serial

Clock

TDM

Test

UT斯达康内部资料 33
iAN8K B1000 TDM Internal Buses

• SCM4 contains the TDM


Cross-connection matrix.
• The SCM4 modules include
an 8192 x 64kbps channel
interchanger (32 x 16M
highway timeslot
16 x 8Mbps Highways (Main & Exp) interchanger TSI).
• It cross connects timeslot
between backplane TDM
8 x 2Mbps Highways (Main & Exp) buses (highways).
• When equipped with:
– 3 Expansion shelves:
4 x 8Mbps Highways (Main only) • 6 x 16Mbps Highways
are sent to each
expansion shelf.
– 1-2 Expansion shelves:
• 8 x 16Mbps Highways
are sent to each
6-8 x 16Mbps Highways to
expansion shelf.
each Expansion shelf 1-3

UT斯达康内部资料 34
iAN8K B1000 Ethernet Bus

• 1-2 x FE bus to each


slot from ICM3:
• 1 x GE bus.
– To SCM4.
– Between ICM3
modules. I I
C C
• Modules that use these M
3
M
3
data buses:
– ICM3.
– IPxDSLx.
– IVD.
– VPM.
– SCM4.
– EOE (future).
2 x FE/1 x GE

1 x GE

UT斯达康内部资料 35
iAN8K B1000 Bus Architecture
(POTS)
POTS + IP
STM-1 E1 POTS + xDSL Ethernet N/W Netman 4000
ADSL
Call Agent
S FE/GE
TDM Bus

FE
S I FE
D E P I I FE SS MCU
F I V FE
T 1E x P C FE CC
XF V I PV FE
- M1 DX M MM
SX DV MP FE
1 LM S D SD 3 4 4
M FE
2 L LS
L External
Clock
Main Shelf

TDM Bus
FE
I FE
P I I EE
F I V FE
x P C BB
XF V I
DX PV FE
SX DV MP FE
M AA
S D SD M FE 3 MM
LS
L FE
Extension Shelf
UT斯达康内部资料 36
Common Modules

UT斯达康内部资料 37
iAN8K B1000 Common Modules

Module Module
Adapter Name Description
Type Name

The System Control Module controls


SCM4 SCM4-RA
the whole system operation.

The Extension Bus Adapter Module


EBAM3 EBAM3-RA extends the main shelf signals to the
extension shelves.
Common
Modules MCU-A (Main shelf) The Power and Ring generator
PRM2/ Module, converts -48V DC to +5V
PRM2-RA DC and ringing voltage. 25 Hz /
PRM2RD
(Extension shelf) 75VAC.

MCU-A (Main shelf) The Power and Ring generator


PRM2B/ Module, converts -48V DC to +5V
PRM2-RA DC and ringing voltage. 20 Hz /
PRM2RDB
(Extension shelf) 60VAC.

UT斯达康内部资料 38
System Control Module (SCM4)

• Brain of the iAN8K B1000. It controls the system


operation:
– V5 and VoIP protocols processing.
– Management features.
– Provides TDM cross-connections.
– Bus extension.
– 1+1 hot redundancy.
– Management of system clock.
– OAM.
• SCM4 module is installed in front slot 17 or 18.

Ü
UT斯达康内部资料 39
System Control Module (SCM4)

• Brain of the iAN8K B1000. It controls the system


operation:
– V5 and VoIP protocols processing.
– Management features.
– Provides TDM cross-connections.
– Bus extension.
– 1+1 hot redundancy.
– Management of system clock.
– OAM.
• SCM4 module is installed in front slot 17 or 18.

UT斯达康内部资料 40
System Control Module (SCM4)

• TSI – 8k x 8k.
• HDLC Channels – 256.
• SDRAM – 256MB.
• Stores system firmware and configuration
parameters.
• Provides software downloads to slave modules.
• Contains SNMP based network management
interface to Netman and serves as SNMP agent
for the iAN8K B1000.
• Controls up to three slave shelves via the
EBAM3 modules.

UT斯达康内部资料 41
SCM4 Faceplate - LEDS

Function Status Description


Communication Fast Flashing Serial Link up.
COMM status with
modules ON / OFF Serial Link down.

Normal Flashing CPU is up and running.


Health of the
COMM
ALIVE ALIVE
CPU
ACT
ALARM
OFF CPU is not operating.

Active module begins driving traffic


Turns on
carrying bus on backplane.

SCM4 Normal Flashing SCM4 is standby.


ACT Operational
Active module drives traffic carrying
status ON
bus on backplane.
SCM4 is Standby and does not drive
OFF
traffic.

Turns on V5/VoIP interfaces are out of service

ALARM Node alarm One or more V5 interfaces are out of


Normal Flashing
status service.
All provisioned interfaces are In
OFF
Service, or none is provisioned.
UT斯达康内部资料 42
SCM4 Faceplate - LEDS

Function Status Description


There are Critical alarms in
CRITICAL ON
the node.
Critical Alarms
COMM There are no Critical alarms
ALIVE OFF
ACT in the node.
ALARM

There are Major alarms in


ALIVE ON
the node.
Major Alarms
SWITCH There are no Major alarms
OFF
RESET in the node.
There are Minor alarms in
ON
ACT the node.
Minor Alarms
There are no Minor alarms
OFF
in the node.

UT斯达康内部资料 43
SCM4 Faceplate – COM3

RJ45
DB9

COMM
ALIVE Twisted Pair
ACT
ALARM
Cable

Line Connections
RJ45 DB9
1 1
RJ45
2 2
Pin 8 3 3
4 4
Pin 1 5 5
6 6
7 7
8 8
9
UT斯达康内部资料 44
SCM4 1:1 Redundancy (RD)

• Forced switchover.
– Command switchover – CLI or NMS reset/switch command.
– Manual switchover – Switch button or module removal.
• Automatic switchover.
– Detection of hardware failure of active SCM4 within 10 ms.
• Effects.
– Established calls are not interrupted.
– New calls can be established in less than 2 seconds after the
switch over.
– Switch over event reports to NMS with date/time stamp.

UT斯达康内部资料 45
SCM4 1:1 RD/Switchover Control

• Criteria for switch over.


– Active board pull-out.
– Active board is reset (manual or hardware self reset).
– Active board hardware failure.
– Active board software in infinite loop.
– Active board software failure.
• Before switchover happens, data shall have been
synchronized from the active to the standby.
• After switchover happens, the new active shall collect
system status to confirm.

UT斯达康内部资料 46
SCM4 1:1 Redundancy

Warning! Do not pull out Active/Standby SCM4


without pressing the Switch button.
• Active SCM4 Pull out.
1. Switch the active SCM4 to standby either via command or press
the switch button in the SCM4 front panel.
2. Wait until synchronization is done between modules.
3. Push the Switch button again for the same module, release the
switch button and wait 3 seconds.
4. Pull out the module from the shelf before 7 seconds.
• Standby SCM4 Pull out.
1. Same procedure as an active SCM4 module.

UT斯达康内部资料 47
SCM4A-RA Adapter

• Provides connection to extension shelf.


• Provides interconnection to another SCM4A-
RA for redundancy.
• Supports ESD protection capability.

UT斯达康内部资料 48
SCM4A-RA Faceplate - Connectors

Interface Type Description


RS485A SCSI20 Connects to the EBAM3A-RA in
RS485B SCSI20 the extension shelves.

Connects to another SCM4A-RA


Intercon SCSI26
module.
BLVDS 1 RJ45
Connects to the EBAM3A-RA
BLVDS 2 RJ45
module in the extension shelves.
BLVDS 3 RJ45
Ethernet1 RJ45 Connects to the ICM3A-RA
module in main shelf.
Ethernet2 RJ45 Note: For future application.

UT斯达康内部资料 49
Expansion Bus Adapter Mod (EBAM3)

• Extends the signals of the main shelf to the


extension shelves.
• EBAM3 is installed in the extension shelf front
17 or 18 slot.

UT斯达康内部资料 50
EBAM3 Faceplate - LEDS

Function Status Description


COMM Fast
Communication Serial Link up.
Flashing
status with SCM4
ON / OFF Serial Link down.
Normal
ALIVE Health of the CPU is up and running.
Flashing
EBAM3 CPU
OFF CPU is not operating.
Turns on Module becomes active.
EBAM3
ACT Normal
Operational Module is in active mode.
Flashing
status
OFF Module is in standby mode.
Note: Normal rate indicates ½ second on and ½ second off with ± 10%
tolerance.
Fast rate indicates ¼ second on and ¼ second off with ± 10% tolerance.

Ü
UT斯达康内部资料 51
EBAM3 Faceplate - LEDS

Function Status Description


COMM Fast
Communication Serial Link up.
Flashing
status with SCM4
ON / OFF Serial Link down.
Normal
ALIVE Health of the CPU is up and running.
Flashing
EBAM3 CPU
OFF CPU is not operating.
Turns on Module becomes active.
EBAM3
ACT Normal
Operational Module is in active mode.
Flashing
status
OFF Module is in standby mode.
Note: Normal rate indicates ½ second on and ½ second off with ± 10%
tolerance.
Fast rate indicates ¼ second on and ¼ second off with ± 10% tolerance.

UT斯达康内部资料 52
EBAM3 Redundancy

• The redundancy of EBAM3 is similar to SCM4 in


hardware.
• There is no synchronization between two EBAM3
modules.
– Its redundancy is controlled by the SCM4.

UT斯达康内部资料 53
EBAM3A-RA Adapter

• The EBAM3-RA is used to connect the EBAM3


module in iAN8K B1000 RA shelf (10U).
– Provide connection to master shelf.
– Provide interconnection to another EBAM3A-RA for
redundancy.
– Support ESD protection capability.
• Installed in extension shelf rear slots 17 and 18.

UT斯达康内部资料 54
EBAM3A-RA Faceplate - Connectors

Interface Type Description


RS485A SCSI20 Connects to the EBAM3A-RA in
other extension shelf (if any) and
RS485B SCSI20 to SCM4A-RA in the main shelf.
Connects to another EBAM3A-RA
Intercon SCSI26
module.
Connects to the SCM4A-RA
BLVDS 1 RJ45
module in the main shelf.

UT斯达康内部资料 55
E1ML Module

• Terminates 8 x G.703/G.704E1/T1 Interfaces.


• Provides 75 Ohm unbalanced or 120 Ohm balanced
Interface (DIP switch selectable).
• Provides LED's for module and port status alarms.
• Performs CRC-4 on the E1/T1 line according to ITU-T
G.706.
• Monitors performance of each E1/T1 line.
• Detects errors and alarms on E1/T1 lines.
• Supports Loopback.

UT斯达康内部资料 56
E1ML Faceplate - LEDS

Function Status Description


COMM Communication Fast Flashing Serial Link up.
status with
SCM4 ON / OFF Serial Link down.
Normal
ALIVE Health of the CPU is up and running.
Flashing
CPU
ON / OFF Module is not operational.
Local A Loss of Signal or Loss of
LOC ON
operation Synchronization is detected.
status of E1 /
T1 OFF The operation is normal.

Remote An alarm was received from


ON
REM operation the remote E1/T1.
status of E1 /
T1 OFF The operation is normal.

Note: Normal rate indicates ½ second on and ½ second off with


± 10% tolerance. Fast rate indicates ¼ second on and ¼ second
off with ± 10% tolerance.

UT斯达康内部资料 57
PRM2/PRMRD2 Modules

• Power Supply Module with Ring Generator


(PRM2/PRMRD2) is used in the RT node.
– It converts -48 VDC to:
• +5 VDC
• Ringing voltage.
– Powers modules via the backplane.
• PRM2 module is installed in upper front P
slot.
• PRMRD2 module (for redundancy) is installed
in the lower front P slot.

UT斯达康内部资料 58
PRM2/PRMRD2 Faceplate - LEDS

Function Status Description

RING Ring voltage OFF Ring output is normal.


status ON Ring output is abnormal.
OFF +5 V output is normal.
+5V +5 V status
ON +5 V output is abnormal.
The -48v for the +5V
ON
-48P -48 V converter is ok.
status The -48v for the +5V
OFF
converter is not present.
The -48v for the ring
ON
-48R -48 V generator is ok.
status The -48v for the ring
OFF
generator is not present.

UT斯达康内部资料 59
PRM2B/PRMRD2B Modules

• Power Supply Module with Ring Generator


(PRM2/PRMRD2) is used in the node which
the ring is necessary.
– It converts -48 VDC to:
• +5 VDC
• Ringing voltage.
– Powers the modules via the backplane.
• PRM2B module is installed in upper front P
slot.
• PRMRD2B module (for redundancy) is
installed in the lower front P slot.

UT斯达康内部资料 60
PRM2B/PRMRD2B Faceplate - LEDS

Function Status Description

RING Ring voltage OFF Ring output is normal.


status ON Ring output is abnormal.
OFF +5 V output is normal.
+5V +5 V status
ON +5 V output is abnormal
The -48v for the +5V
ON
-48P -48 V converter is ok.
status The -48v for the +5V
OFF
converter is not present.
The -48v for the ring
ON
-48R -48 V generator is ok.
status The -48v for the ring
OFF
generator is not present.

UT斯达康内部资料 61
Main Control Unit (MCUA-RA) Adapter

• Monitors the general condition of the iAN8K


B1000 system.
• Displays alarms generated by the system
devices.
• Installed in main shelf adapter rear slot P.

UT斯达康内部资料 62
MCUA-RA Faceplate - LEDS

Function Status Description


Flashing at MCU-A downloads firmware
100 ms ON from SCM4, and SCM4
and 100 ms responds to it. MCU-A run
OFF. normally in main shelf.
Flashing at
MCU-A downloads firmware
1 sec ON
from SCM4, but SCM4 does
COMM MCUA-RA run and 1 sec
not respond to it.
status OFF.
Flashing at
50 ms ON MCU-A is plugged into
and 50 ms extension shelf falsely.
OFF
MCU-A Work at diagnostic
ON
Mode.

UT斯达康内部资料 63
MCUA-RA Faceplate - Connectors

• The MCUA-RA faceplate has 13 external


connectors to.
– PDP.
– NMS.
– Clock sources.
– External alarms.
– Alarms in expansion shelves.
– Test devices.

UT斯达康内部资料 64
PRM2A-RA Adapter

• PRM2A-RA is used to provide alarms collection


and test bus connection for extension shelves.
– Provides Test bus connections.
– Transmits fan and power alarms to the
MCUA-RA.
– Support ESD protection capability.
• Installed in extension shelf (10U) adapter
slot P.

UT斯达康内部资料 65
PRM2A-RA Faceplate - Connectors

Cable
Interface Type Description
Type
10/100
TEST 1 RJ45
Base-T
Used for test bus.
10/100
TEST 2 RJ45
Base-T
Connects to the ALMIN
10/100 port in the MCUA-RA
ALARM RJ45
Base-T module, sends fan and
power alarms.

UT斯达康内部资料 66
Application Modules

UT斯达康内部资料 67
MSAN Modules (1/3)

Module Module
Adapter Name Description
Type Name
The remote user module provides 48 POTS
FXS9 GLS48B-RA
subscriber connections.

TDM user Provides 16 analog interfaces for the central


FXO
Interface office in the UNLC configuration.
Module The basic rate interface module has 8 ISDN user
BRI GLS24A-RA
interfaces.
The SHDSL user module has eight TDM based
SHTM
SHDSL user interfaces.
IP
The IP convergence module has two GE uplink
Convergence ICM3 ICM3-RA
interfaces + 4 FE interfaces (through adapter).
Module
The remote test module, used for TDM user line
Test Module RTM-S None
test (iTest).

UT斯达康内部资料 68
MSAP Modules (2/3)

Module
Module Type Description
Name Adapter Name
The ADSL user module
AD48x-RA(B)
IPADSL6A/B provides 48 ADSL user
IPxDSL User x=A,B,C,D
connections.
Interface Module
The [Link] user module
IPSHDSL3 HSL24B-RA provides 24 [Link] user
connections.
Combines IPADSL3A and
IVD User Interface
IVD-24BT IVD-24A-RA FXS-24BT modules with built-
Module
in splitters.

VOIP Process The voice process module


VPM VPMA-RA
Module provides voice over IP function.
GEE8x-RA
X=A, B
E1ML The E1 convergence module
A=75ohms
TDM
B=120ohms has eight E1 interfaces.
Convergence
Module The STM-1 convergence
SDT12 SDT12A-RA
(63 / 55+8) (only for SDT12 55+8) module has two STM-1
interfaces.

UT斯达康内部资料 69
MSAP Modules (3/3)

Module
Module Type Adapter Name Description
Name
OAM Module for the MSAN.
Controls management, alarms,
statistics, handles software an
SCM4 SCM4A-RA
firmware for other cards and
communicates with extension
shelves.
Common
Module in the extension shelf
Modules
which connects to SCM4 for
EMAB3 EBAM3-FA
shelf management, traffic
management, timing.

MCUA-RA (Main shelf)


PRM Power modules.
PRM2A-RA (Extension shelves)

UT斯达康内部资料 70
MSAN Module Installation Rules

UT斯达康内部资料 71
Module Installation Rules

Slot Virtual
Module Assignment Shelf Assignment Notes
CT RT Supporting
BRI Front Front Main/ Yes • When the BRI is installed in slots 2-15, the FXS24BT,
2–15 2–15 Extension FXS24P4, FXS24P4T, E&M3 or FXO3 cannot be installed in
the slots 1 and 16.
• When the BRI is installed in slots 2, the IPADSL3A, IVD, ICM3
cannot be installed in the shelf.
E1ML Front Front Main/ Yes • E1ML is a eight ports module with long haul E1.
1–17 1–17 Extension • Up to 25 E1ML modules for a single node.

SDT12 Front Front Main Yes • Only one SDT12 board can be installed in a node.
1–17 1–17

FXO Front Front Main/ No • When the BRI is installed in slots 2-15, the FXO cannot
1–16 1–16 Extension be installed in the slots 1 and 16.
• When the ICM3 is installed in slots 2, the FXO cannot be
installed in the shelf.

IVD-24BT Front Front Main/ Yes • Not allowed in slot 17.


3–16 3–16 Extension • When the BRI, FXO3, ICM3 is installed in slot 2, the IVD-
24BT cannot be installed in the shelf.
• When the BRI is installed in slots 3-15, the IVD-24BT
cannot be installed in the slots 16.

UT斯达康内部资料
Ü 72
Module Installation Rules

Slot Virtual
Module Assignment Shelf Assignment Notes
CT RT Supporting

FXS9 Front Front Main/ Yes


3–17 3–17 Extension

RTM-S Front Front Main/ No • Only one RTM-S module can be installed per node.
1-17 1-17 Extension
PRM2 Front Front Main/ No
P P Extension
PRMRD2 Front Front Main/ No
P P Extension

VPM Front Front Main/ Yes • Up to four VPM modules can be installed in a single
3–17 3–17 Extension node.
• When an ICM3 is installed in the shelf, do not connect
the Ethernet port in the VPM module to other switch
devices.

UT斯达康内部资料
Ü
73
Module Installation Rules

Slot Virtual
Module Assignment Shelf Assignment Notes
CT RT Supporting
ICM3 Front Front Main/ No • When the FXS (except FXS24BT), E&M or FXO is
1, 2 1, 2 Extension installed in slot 1, the ICM3 cannot be installed in slot 2 at
the same time.
IPSHDSL3 Front Front Main/ Yes • When the BRI or FXO3 is installed in slot 2, the IPSHDSL3
3–16 3–16 Extension cannot be installed in the shelf.
IPADSL6A Front Front Main/ Yes • When the BRI, E&M3, FXO3 , is installed in slot 2, the
3–16 3–16 Extension IPADSL6A/IPADSL6B cannot be installed in the shelf.

SCM4 Front Front Main Yes • One (active) or two (standby) can be installed.
17,18 17,18 • Recommended to plug in Slot 17 first:
• Software recognizes SCM4 slot 17 as active in default.
• Slot 17 has better venting state than Slot 18.

EBAM3 Front Front Extension No • Must be installed in the extension shelf to connect with the
17,18 17,18 main and other extension shelves.
• When two SCM4 are installed in the main shelf, there must be
two EBAM3 in each extension shelf.

SHTM Front Front Main/ Yes • Up to ten SHTM modules can be installed in a single
1–17 1–17 Extension node. Only first 4 ports of 10th SHTM can be used.

UT斯达康内部资料 74
Initial Configuration

UT斯达康内部资料 75
SCM4 Ports

• Node’s management IP address is managed by the


SCM4 module.
• SCM4 Ethernet management port is located physically
on the rear MCUA board (MCUA-RA) and internally it is
called eth1.
• A serial console connection is required for configuring
during the initial setup process the SCM4 IP Address.
• Console connection is done in the SCM4 COM3 port.

UT斯达康内部资料 76
SCM4 Serial Port

Serial Cable Pin Details


Pin No. Pin No.
(RJ-45) Signal (DB9) Signal
1 RI No Connection
2 CD 4 DTR No Connection
COMM
ALIVE
3 DTR 6 DSR No Connection
ACT
ALARM 4 GND 5 GND
5 RX 3 TX
6 TX 2 RX
7 CTS 7 RTS No Connection
8 DCD 8 CTS No Connection
RJ45
1 DCD No Connection

PC
COM Port
9-Pin

RS-232 Cable

UT斯达康内部资料 77
Console To SCM4

To connect through a console:


– Reset the SCM4 card.
• Press reset button.
• Remove/Replace the module in its slot.
– Use a console software to connect to the module (9600,8,N,1).

SCM4 >
Set ethernet port address
SCM4 > setaddr eth1 [Link] [Link]
SCM4> routed: ignore RTM_ADD without gateway
routed: IP_DROP_MEMBERSHIP ALLROUTERS:
routed: IP_ADD_MEMBERSHIP ALLROUTERS: Address already in use
routed: setsockopt(IP_ADD_MEMBERSHIP RIP): Address already in use
routed: write(rt_sock) RTM_ADD [Link]/24 --> [Link]: File exists
SCM4 > rtadd [Link] [Link] [Link] Set IP default gateway
writing to routing socketadd net [Link]: gateway [Link]: File exists
routed: receiving our own change messages
SCM4 > sipcfg Save ethernet settings
Saving /flash/[Link]
SCM4 > exit
UT斯达康内部资料 78
B1000 Initial Configuration

• Basic parameters include:


– System Information.
– IP Addresses.
– Routing Information.
– Synchronization Configuration (Timing).
– Synchronize SCM4 (Dual configuration).
• These parameters are stored and managed in the SCM4
module.
• Power modules and EBAM3 cannot be managed.
• RTM-S module to be covered in another course.

UT斯达康内部资料 79
Node Basic: System Information

• System Info – Node identification like Name, Location,


Contact Information.

UT斯达康内部资料 80
Node Basic: IP Addresses

• Node IP Addr.
– Active/Standby SCM4s.
– Subnet Mask.
• Default Gateway Addr.
• PPP Interface Peer Addr.
– Address assigned to PPP
peer (computer).
• Signaling IP Addr.
• Trap Destination IP
Address (SNMP).
• Time Server Addr.
• RIP Setup.
– Management information
routing protocol.

UT斯达康内部资料 81
Node Basic: Route Information

• Routing table auto-


populated by the
routing protocol
configured previously
(RIP).
• Mainly used for routing
management
information.
• Static routes may be
configured if required.

UT斯达康内部资料 82
Node Basic: Clock Source

UT斯达康内部资料 83
Save Configuration

• iAN8K B1000 configuration changes are done only in RAM, not in


the actual configuration files in the flash memory.
• Save Configuration command must be issued to save all
configuration changes.
UT斯达康内部资料 84
Sync SCM4s

• Program and
configuration
synchronization
between SCM4s in a
Dual SCM4
environment is not
done automatically
by default.
• Auto Flash Sync
enables automatic
synchronization
between Active and
Stand-by SCM4.

UT斯达康内部资料 85
Module Review

• Do you have questions regarding any of the content


presented in this module?
– Shelf types.
• RA.
• FA.
– Front slots: Modules.
– Rear slots: Adapters.
– 3 Fan Tray slots.

UT斯达康内部资料
Ü
86
Module Review

• D you have questions about any of the content


presented in this module?
– Power.
• PDP300R/F.
• CPM1/2.
– Main Shelf Cabling.
– Internal Busses.
• Communication.
• Clock.
• TDM.
• Ethernet.
• Test.

UT斯达康内部资料
Ü
87
Module Review

• Do you have questions about any of the content


presented in this module?
– Multi-chassis Configuration.
• 1 Master + up to 3 slaves.
• Only TDM/Clock buses are extended to expansion shelves.
– Common Modules.
• SCM4 <-> SCM4A-RA: Master Shelf.
• EBAM3 <-> EBAM3A-RA: Expansion Shelves.
• PRM2/RD(B) <->.
– MCUA-RA: Master Shelf.
– PRM2A-RA: Expansion Shelves.
– Initial Configuration.

UT斯达康内部资料
Ü