API 675
Maximum Flow Rate: 30.28 L/hr (8.00 gph)
Minimum Flow Rate: 0.227 L/hr (0.06 gph)
Maximum Pressure: 241 bar (3500 psi) for Metallic Pump Heads
24 bar (350 psi) for Non-metallic Pump Heads
MT8 with PVC pump head. MT8 with PVDF pump head.
2 • www.Hydra-Cell.co.uk
MT8 Pump
Performance Flow Capacities and Pressure Ratings
For Synchronous Speed, Self-cooled Motors For 10:1 Turndown, Self-cooled Motors
L/hr Maximum Flow at Designated Pressure L/hr Maximum Flow at Designated Pressure
All Pumps (L/hr) Pump Gear Motor All Pumps (L/hr) Pump Gear Motor
34 bar 103 bar 172 bar 241 bar RPM Ratio RPM 34 bar 103 bar 172 bar 241 bar RPM Ratio RPM
1.49 1.36 1.23 1.08 15 100:1 1.49 1.36 1.23 1.08 15 100:1
1.85 1.68 1.52 1.35 18.75 80:1 1.85 1.68 1.52 1.35 18.75 80:1
2.45 2.22 2.01 1.79 25 60:1 2.45 2.22 2.01 1.79 25 60:1
3.03 2.75 2.51 2.26 30 50:1 3.03 2.75 2.51 2.26 30 50:1
3.72 3.44 3.11 2.81 37.5 40:1 1500 3.72 3.44 3.11 2.81 37.5 40:1 1500
5.03 4.54 4.13 3.72 50 30:1 5.03 4.54 4.13 3.72 50 30:1
7.30 6.65 6.08 5.46 75 20:1 7.30 6.65 6.08 5.46 75 20:1
14.71 13.44 12.13 10.83 150 10:1 14.71 13.44 12.13 10.83 150 10:1
19.44 17.55 15.99 14.10 200 7.5:1 19.44 17.55 15.99 14.10 200 7.5:1
29.16 26.33 23.12 20.63 300 5:1 29.16 26.33 23.12 20.63 300 5:1
Required Motor kW Required Motor kW
0.37 0.18 0.25 0.37 0.55
Notes:
1. The motor kW are based on ambient temperature conditions up to Please Note:
25˚C. For ambient temperatures above 25˚C, Force-cooled Motors Systems vary. The MT8 pump must be calibrated once installed to
may be required. Please contact Wanner International. ensure optimum performance. The API 675 Performance Standard
is achievable for flow rates as low as 0.227 L/hr. Please contact the
2. Contact factory for performance specifications.
factory for assistance.
3. Based on using IE2 motors.
4. Maximum continuous motor speed is 1500 RPM at full pressure.
5. For intermittent or reduced pressure duties, please contact Wanner See Page 6 for Electronic Flow Rate Controller.
International.
6. Flow rates above 30.28 L/hr are not guaranteed to meet API 675
Performance Standards. To reach a flow rate of 30.28 L/hr with a 5:1
gear box and 1500 RPM motor, the VFD will need to be programmed
for operation above 50 Hz.
www.Hydra-Cell.co.uk • 3
MT8 Pump
Representative Drawings Inches (mm)
Metallic Pump Heads Metallic Heads with Manual Adjustment
12.00
.50 (304.8)
(12.7)
12.00
.50 (304.8)
(12.7)
3.63
(92.08) 3.63
(92.08)
4X Ø 0.360
(9.1)
4X Ø 0.360
(9.1)
14.00
(355.6)
14.00
(355.6)
14.20 3.625
(360.68) 14.20
(92.1)
(360.68) 12.00
(304.8) 8.70
(220.98) 8.70 2
(220.98)
.400
(10.16) .4001.25 7.75 4X Ø .36
(10.16)
(31.75) 1.25 (196.85) 7.75 (9.14) 4X Ø .36
(31.75) (196.85) (9.14)
14.12
(358.6)
14.00 14.12 8.700
(355.6) (358.6) (221.0)
4X 1/4 NPT or BSPT
4X 1/4 NPT or BSPT
70 9.15 9.62
0.98) (232.48) 9.15 3.97 2X 0.400 12.00 4X Ø 0.360 (244.3)
(232.48) (100.84) 3.97
(10.2)
9.88 (304.8) (9.1)
(100.84) 9.88 9.62
(250.95) (244.3)
(250.95)
15.00
12.59 2.00 (381) 15.00
(319.84) 12.59 (50.67) 2.00 (381)
(319.84) (50.67)
14.12
(358.6)
9.62
(244.3)
9.88
(250.95)
15.00
.00 (381) 16.66
0.67) (423.2)
MT8 Version-7 08.21
Note: Dimensions are for reference only. Contact Wanner International for certified drawings.
4 • www.Hydra-Cell.co.uk
MT8 Pump
Representative Drawings Inches (mm)
Metallic Heads with Duplexing Option
7.25
4X Ø .36
(184.15)
(9.14)
4X Ø .36 1.50
(9.14) (38.1)
22.51
(571.8)
7.25
(184.15)
4X Ø .36 1.50
(9.14) (38.1)
9.15
(232.48) 3.97 9.88
1/4 NPT or BSPT 22.51 (100.84) (250.95)
(571.8)
12.95 2.00
3.97 9.88
(328.85) (50.67)
(100.84) (250.95)
2.00 23.31
X 1/4 NPT or(50.67)
BSPT (592.12)
3.97 9.88
(100.84) (250.95)
2.00 23.31
(50.67) (592.12)
MT8 Version-7 08.21
Note: Dimensions are for reference only. Contact factory for certified drawings.
www.Hydra-Cell.co.uk • 5
MT8 Pump
How to Order
A complete pump order number contains 16 digits based on the specified pump materials listed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
M T J N
Pump Model Size (Digits 1-2) Pump Data
MT Metering Triplex Pumps
Pump Capacity (Digits 3-4) Diaphragms per Liquid End 3
08 0.227 - 30.28 L/hr (0.06 - 8.00 gph) Flow Control Electronic variable speed drive or manual adjustment
8D MT8 Duplex 0.454 - 60.56 lph (0.12 - 16 gph)
Pump Version (Digit 5)
Maximum Discharge Pressure
N NPT Ports Metallic Heads: 241 bar (3500 psi)
M BSPT Ports Non-metallic Heads: 24 bar (350 psi)
Pump Head (Digits 6-7)
Maximum Inlet Pressure
SN 316 SST
TN Hastelloy C Metallic Heads: 34 bar (500 psi)
AN Alloy 20 Non-metallic Heads: 300 psi (21 bar)
VN PVC Operating Temperatures (min./max.)
MN PVDF
Diaphragm (Digit 8)
Metallic Heads: 4.4˚C (40˚F) to 121˚C (250˚F)
J PTFE (FDA-compliant wetted PTFE materials available on Non-metallic Heads: 4.4˚C (40˚F) to 60˚C (140˚F)
request - consult Wanner International) Consult factory for temperatures outside this range
Leak Detection Style (Digit 9)
N No leak detection Inlet Port 1/4 inch BSPT or NPT
CV Ball/Seat (Digits 10-11) Discharge Port 1/4 inch BSPT or NPT
SS 316 SST / 316 SST Maximum Solids Size 200 microns
TT Hastelloy C / Hastelloy C
Suction Lift Capability 6.1 meters (20 feet)
AA Alloy 20 / Alloy 20
Oil (Digit 12) Shaft Rotation Bi-directional
G 5W30 (Synthetic oil) Oil Capacity 1.7 litres (1.75 US quarts)
K Food-contact oil Weight (less motor)
Motor Flange Size (Digit 13)
A NEMA 56C Metallic Heads: 45 kg (100 lbs.)
B NEMA 143/145TC Non-metallic Heads: 34 kg (75 lbs.)
C IEC 63 B5
D
E
IEC 71 B5
IEC 80 B5
Accessories, Options & Services
H NEMA 56C (MA only) Consult Wanner International for complete details about
L IEC 71 B14 (MA only) available accessories and options as well as special services.
M IEC 80 B14 (MA only)
• Duplexing Models
Gearbox Ratio (Digits 14-15)
00 100:1 • Different Gearbox Ratios
80 80:1 Manual adjustment controller available • Actuating Oils
60 60:1 for fixed-ratio gearboxes to be ordered • Magnetic Drain Plug
50 50:1 as an accessory. • Motors (Standard/Hazardous-duty)
40 40:1
30 30:1 • Controllers
20 20:1 • Control Freak Touch-screen Metering Controller
10 10:1 • SmartDrive Motor-Controller
07 7.5:1
05 5:1
• Calibration Cylinders
MA Manual adjustment • Back Pressure Valves
(specify H, L or M flange for this option) • Pressure Relief Valves
Baseplate (Digit 16)
C Carbon Steel (Epoxy painted) • Testing Services
S SST • System Components, Priming Kits and Plugs
MT8 Version-7 08.21
M Carbon Steel (Epoxy painted) Manual adjustment • Replacement Part Kits and Tool Kits
T SST Manual adjustment
• Pulsation Dampeners
• Customisation Services
6 • www.Hydra-Cell.co.uk
MT8 Pump
Hydra-Cell® Metering and Dosing Control Options
On-board Hand-held
keypad control keypad control
MT8 Version-7 08.21
www.Hydra-Cell.co.uk • 7
MT8 Pump
7 0 C ount ries
ers in o v e r
Partn
Standards Compliance