MT8 Pump

API 675
Maximum Flow Rate: 30.28 L/hr (8.00 gph)
Minimum Flow Rate: 0.227 L/hr (0.06 gph)
Maximum Pressure: 241 bar (3500 psi) for Metallic Pump Heads
24 bar (350 psi) for Non-metallic Pump Heads

MT8 with Stainless Steel pump head


Hydra-Cell Metering Solutions pumps exceed API 675
performance standards for Steady-State Accuracy (±1%),
Linearity (±3%), and Repeatability (±3%).

Triplex Metering Pump with Virtually Pulse-free Linear Flow


• Multiple-diaphragm design provides virtually pulse-free, linear • Duplexing option doubles capacity and equipment savings.
flow without the need for expensive pulsation dampeners. • One pump covers a wide range of flows and pressures
• Designed for low flow rates at high pressures. - reducing inventory requirements with fast, simple field
• Can run dry indefinitely. conversion.
• Will operate without damage to the pump in the event of a • Hydraulically-actuated, balanced diaphragms provide
blocked suction line. superior performance across the entire pressure range.
• Handles a variety of processing fluids. • Seal-less design means no seals, cups, or packing to leak or
replace.
• Electronic flow control increases accuracy and reliability.
• The replenishment valve system in every piston ensures
• The integral relief valve protects the pump from over
optimum actuating oil on every stroke for continuous
pressurisation on the discharge side.
accuracy and protects the pump from damage in the event
• Rugged construction with sealing oil cap.
of a blocked suction line.
• Smaller footprint saves valuable space.
MT8 Version-7 08.21
MT8 Pump
MT8 Materials and Configurations

MT8 with PVC pump head. MT8 with PVDF pump head.

MT8 with manual variable speed gearbox.

Two MT8 pumps run at the same flow


rate with only one gearbox and one
motor. This “duplexing” option doubles
capacity with a smaller footprint and
lower investment cost than conventional
metering pumps. Two different chemicals
MT8 with duplexing option.
can be metered in a 1:1 ratio.
MT8 Version-7 08.21

2 • www.Hydra-Cell.co.uk
MT8 Pump
Performance Flow Capacities and Pressure Ratings

For Synchronous Speed, Self-cooled Motors For 10:1 Turndown, Self-cooled Motors
L/hr Maximum Flow at Designated Pressure L/hr Maximum Flow at Designated Pressure

All Pumps (L/hr) Pump Gear Motor All Pumps (L/hr) Pump Gear Motor
34 bar 103 bar 172 bar 241 bar RPM Ratio RPM 34 bar 103 bar 172 bar 241 bar RPM Ratio RPM
1.49 1.36 1.23 1.08 15 100:1 1.49 1.36 1.23 1.08 15 100:1
1.85 1.68 1.52 1.35 18.75 80:1 1.85 1.68 1.52 1.35 18.75 80:1
2.45 2.22 2.01 1.79 25 60:1 2.45 2.22 2.01 1.79 25 60:1
3.03 2.75 2.51 2.26 30 50:1 3.03 2.75 2.51 2.26 30 50:1
3.72 3.44 3.11 2.81 37.5 40:1 1500 3.72 3.44 3.11 2.81 37.5 40:1 1500
5.03 4.54 4.13 3.72 50 30:1 5.03 4.54 4.13 3.72 50 30:1
7.30 6.65 6.08 5.46 75 20:1 7.30 6.65 6.08 5.46 75 20:1
14.71 13.44 12.13 10.83 150 10:1 14.71 13.44 12.13 10.83 150 10:1
19.44 17.55 15.99 14.10 200 7.5:1 19.44 17.55 15.99 14.10 200 7.5:1
29.16 26.33 23.12 20.63 300 5:1 29.16 26.33 23.12 20.63 300 5:1
Required Motor kW Required Motor kW
0.37 0.18 0.25 0.37 0.55

Notes:
1. The motor kW are based on ambient temperature conditions up to Please Note:
25˚C. For ambient temperatures above 25˚C, Force-cooled Motors Systems vary. The MT8 pump must be calibrated once installed to
may be required. Please contact Wanner International. ensure optimum performance. The API 675 Performance Standard
is achievable for flow rates as low as 0.227 L/hr. Please contact the
2. Contact factory for performance specifications.
factory for assistance.
3. Based on using IE2 motors.
4. Maximum continuous motor speed is 1500 RPM at full pressure.
5. For intermittent or reduced pressure duties, please contact Wanner See Page 6 for Electronic Flow Rate Controller.
International.
6. Flow rates above 30.28 L/hr are not guaranteed to meet API 675
Performance Standards. To reach a flow rate of 30.28 L/hr with a 5:1
gear box and 1500 RPM motor, the VFD will need to be programmed
for operation above 50 Hz.

Manual Adjustment Controller


All Min/Max flow rates in litres/hour
34 bar 103 bar 172 bar 241 bar Pump Gearbox Model Required Motor
Min Max Min Max Min Max Min Max RPM Ratio Number Size & Frame
2.01 0.23 1.82 0.23 1.65 0.23 1.49 20 30:1
2.92 2.66 2.43 2.18 30 20:1
5.88 5.38 4.85 4.33 60 10:1 MEC1 - 63B14 0.18kW / IEC 63 / B14 / 4-Pole
7.78 7.02 6.40 5.64 80 7.5:1
0.23 0.23 0.23 0.23
11.67 10.53 9.25 /
120 5:1
/ 120 / / 8.25 0.25kW / IEC 71 / B14 / 4-Pole
MEC3 - 71B14
30.32 30.32 / / 472 0.37kW / IEC 71 / B14 / 4-Pole
472 *
MT8 Version-7 08.21

/ / 30.32 30.32 472 MEC5 - 80B14* 0.75kW / IEC 80 / B14 / 4-Pole


* For MT8 direct coupled to manual adjustment controller, without gearbox.

www.Hydra-Cell.co.uk • 3
MT8 Pump
Representative Drawings Inches (mm)
Metallic Pump Heads Metallic Heads with Manual Adjustment
12.00
.50 (304.8)
(12.7)
12.00
.50 (304.8)
(12.7)
3.63
(92.08) 3.63
(92.08)

4X Ø 0.360
(9.1)
4X Ø 0.360
(9.1)

14.00
(355.6)
14.00
(355.6)

14.20 3.625
(360.68) 14.20
(92.1)
(360.68) 12.00
(304.8) 8.70
(220.98) 8.70 2
(220.98)

.400
(10.16) .4001.25 7.75 4X Ø .36
(10.16)
(31.75) 1.25 (196.85) 7.75 (9.14) 4X Ø .36
(31.75) (196.85) (9.14)

14.12
(358.6)
14.00 14.12 8.700
(355.6) (358.6) (221.0)
4X 1/4 NPT or BSPT
4X 1/4 NPT or BSPT

70 9.15 9.62
0.98) (232.48) 9.15 3.97 2X 0.400 12.00 4X Ø 0.360 (244.3)
(232.48) (100.84) 3.97
(10.2)
9.88 (304.8) (9.1)
(100.84) 9.88 9.62
(250.95) (244.3)
(250.95)

15.00
12.59 2.00 (381) 15.00
(319.84) 12.59 (50.67) 2.00 (381)
(319.84) (50.67)

14.12
(358.6)

9.62
(244.3)
9.88
(250.95)

15.00
.00 (381) 16.66
0.67) (423.2)
MT8 Version-7 08.21

Note: Dimensions are for reference only. Contact Wanner International for certified drawings.

4 • www.Hydra-Cell.co.uk
MT8 Pump
Representative Drawings Inches (mm)
Metallic Heads with Duplexing Option

7.25
4X Ø .36
(184.15)
(9.14)

4X Ø .36 1.50
(9.14) (38.1)

22.51
(571.8)

7.25
(184.15)

4X 1/4 NPT or BSPT

4X Ø .36 1.50
(9.14) (38.1)
9.15
(232.48) 3.97 9.88
1/4 NPT or BSPT 22.51 (100.84) (250.95)
(571.8)

12.95 2.00
3.97 9.88
(328.85) (50.67)
(100.84) (250.95)

2.00 23.31
X 1/4 NPT or(50.67)
BSPT (592.12)

3.97 9.88
(100.84) (250.95)

2.00 23.31
(50.67) (592.12)
MT8 Version-7 08.21

Note: Dimensions are for reference only. Contact factory for certified drawings.

www.Hydra-Cell.co.uk • 5
MT8 Pump
How to Order
A complete pump order number contains 16 digits based on the specified pump materials listed below.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
M T J N
Pump Model Size (Digits 1-2) Pump Data
MT Metering Triplex Pumps
Pump Capacity (Digits 3-4) Diaphragms per Liquid End 3
08 0.227 - 30.28 L/hr (0.06 - 8.00 gph) Flow Control Electronic variable speed drive or manual adjustment
8D MT8 Duplex 0.454 - 60.56 lph (0.12 - 16 gph)
Pump Version (Digit 5)
Maximum Discharge Pressure
N NPT Ports Metallic Heads: 241 bar (3500 psi)
M BSPT Ports Non-metallic Heads: 24 bar (350 psi)
Pump Head (Digits 6-7)
Maximum Inlet Pressure
SN 316 SST
TN Hastelloy C Metallic Heads: 34 bar (500 psi)
AN Alloy 20 Non-metallic Heads: 300 psi (21 bar)
VN PVC Operating Temperatures (min./max.)
MN PVDF
Diaphragm (Digit 8)
Metallic Heads: 4.4˚C (40˚F) to 121˚C (250˚F)
J PTFE (FDA-compliant wetted PTFE materials available on Non-metallic Heads: 4.4˚C (40˚F) to 60˚C (140˚F)
request - consult Wanner International) Consult factory for temperatures outside this range
Leak Detection Style (Digit 9)
N No leak detection Inlet Port 1/4 inch BSPT or NPT
CV Ball/Seat (Digits 10-11) Discharge Port 1/4 inch BSPT or NPT
SS 316 SST / 316 SST Maximum Solids Size 200 microns
TT Hastelloy C / Hastelloy C
Suction Lift Capability 6.1 meters (20 feet)
AA Alloy 20 / Alloy 20
Oil (Digit 12) Shaft Rotation Bi-directional
G 5W30 (Synthetic oil) Oil Capacity 1.7 litres (1.75 US quarts)
K Food-contact oil Weight (less motor)
Motor Flange Size (Digit 13)
A NEMA 56C Metallic Heads: 45 kg (100 lbs.)
B NEMA 143/145TC Non-metallic Heads: 34 kg (75 lbs.)
C IEC 63 B5


D
E
IEC 71 B5
IEC 80 B5
Accessories, Options & Services
H NEMA 56C (MA only) Consult Wanner International for complete details about
L IEC 71 B14 (MA only) available accessories and options as well as special services.
M IEC 80 B14 (MA only)
• Duplexing Models
Gearbox Ratio (Digits 14-15)
00 100:1 • Different Gearbox Ratios
80 80:1 Manual adjustment controller available • Actuating Oils
60 60:1 for fixed-ratio gearboxes to be ordered • Magnetic Drain Plug
50 50:1 as an accessory. • Motors (Standard/Hazardous-duty)
40 40:1
30 30:1 • Controllers
20 20:1 • Control Freak Touch-screen Metering Controller
10 10:1 • SmartDrive Motor-Controller
07 7.5:1
05 5:1
• Calibration Cylinders
MA Manual adjustment • Back Pressure Valves
(specify H, L or M flange for this option) • Pressure Relief Valves
Baseplate (Digit 16)
C Carbon Steel (Epoxy painted) • Testing Services
S SST • System Components, Priming Kits and Plugs
MT8 Version-7 08.21

M Carbon Steel (Epoxy painted) Manual adjustment • Replacement Part Kits and Tool Kits
T SST Manual adjustment
• Pulsation Dampeners
• Customisation Services
6 • www.Hydra-Cell.co.uk
MT8 Pump
Hydra-Cell® Metering and Dosing Control Options

Electronic Flow Rate Adjustment for Control FreakTM for Sophisticated


Local Control Local Control
• IP66 Standard • Option available to control up to 6 x Hydra-Cell pumps with
• Various flow rate adjustments options including: one Hydra-Cell Control Freak
- On-board potentiometer(s) • Multiple Variable Frequency Dive (VFD) options
- On-board keypad controller with flow rate display • Enables programming for flow rate or totalisation
- Removable, hand-held key-pad controller for • Allows up to 10 x separate batch sequences
authorised personnel only • Built-in Calibration mode

Manual Flow Rate Adjustment for


Local Control
• Linear fine adjustment scale on hand-wheel
• High reliability due to frictionless design
• Option to fit a mechanical lock to prevent unauthorised flow
rate change

On-board Hand-held
keypad control keypad control
MT8 Version-7 08.21

www.Hydra-Cell.co.uk • 7
MT8 Pump

7 0 C ount ries
ers in o v e r
Partn

Standards Compliance

• API 675 performance testing, both witnessed and non-witnessed


available. (Consult your local Wanner office for further details.)

Wanner Pumps Ltd.


WANNER INTERNATIONAL WANNER ENGINEERING WANNER PUMPS
UNITED KINGDOM WORLD HEADQUARTERS & Kowloon HONG KONG
8 & 9 Fleet Business Park MANUFACTURING t +852 3428 6634
Sandy Lane • Church Crookham Minneapolis USA e: [email protected]
Hampshire UK GU52 8BF t+1 612-332-5681 Wanner Pumps Ltd.
t +44(0) 1252 816847 e: [email protected] Shanghai CHINA
e: [email protected] t +88 21 6876 3700
REGIONAL OFFICE e: [email protected]
Texas USA
t+1 940-322-7111 Wanner Pumps Ltd.
e: [email protected]

LATIN AMERICAN OFFICE


São Paulo, Brazil
MT8 Version-7 08.21

OFFICIAL UK DISTRIBUTOR: t +55 (11) 99582-1969


Michael Smith Engineers Limited e: [email protected]
www.michael-smith-engineers.co.uk
[email protected]
0800 316 7891 www.hydra-cell.co.uk

You might also like