Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital
Electrical Transducer since 1989
USER MANUAL
WBV414U09 AC voltage transducer
www.wbsensor.com
[email protected]
Technical Service: 86 816 2778271
Quality Complain: 86 816 2278273
Fax Line: 86 816 2281934
ISO9001 ISO14000 ISO18000
Certified
Quality Warranty
Any quality problem found in WB series products, we offer
Three years free charge of repair the products, and six months guaranteed free charge of change and return the
products.
2
WBV414U09 AC Voltage Transducer
Safety claim
The information in the safety claim of the equipment documentation is intended to ensure that
equipment is properly installed in order to maintain it in a condition.
It is assumed that everyone who would be associated with the equipment should be familiar with
the contents of that safety section, or this safety guide.
When electrical equipment is in operation, dangerous voltages will be present in certain parts of
the equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or
improper use may endanger personnel and equipment and course personal injury or physical
damage.
Before working in the terminal strip area, the equipment must be isolated.
Proper and safe operation of the equipment depends on appropriate shipping and handling, proper
storage, installation and commissioning, and on careful operation, maintenance and servicing.
The operating manual for the equipment gives instructions for its installation, commissioning, and
operation. However, the manual cannot cover all conceivable circumstances or include detailed
information on all topics. In the event of questions or specific problem, do not take any action
without proper authorization. Contact the appropriate WB technical sales office and request the
necessary information.
Standard application
1. Accuracy
Accurate degree is conformed to IEC688:1992
2. Safety
2.1 Overload capability
Overload capability is conformed to IEC688:1992
2.2 Isolation voltage
Can be endured testing voltage is conformed to Q/72085584-0.1-2004
2.3 Insulation impedance
The insulation impedance is no less than 20M Ohm, is conformed to
Q/72085584-0.1-2004
3. Electromagnetic Capability
3.1 Electromagnetic field immunity test according to IEC 61000-4-3:1995
3.2 Power frequency magnetic field immunity test according to IEC 61000-4-8:1993
Product Description and Application
WBV414U09 converts AC input voltage into a load independent output signal DC 4-20mA. It has
adopted electromagnetic isolation principle and average measurement method for real time
measurement of AC voltage from electric net or electric circuit.
Mianyang Weibo Electronic Co.,Ltd. 2
No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China
Tel: 86-0816-2971265 Fax: 86-016-2281934
www.wbsensor.com
[email protected] 3
The product has certain advantages of total galvanic isolation between input/output and auxiliary
power, high accuracy, low drifting by temperature, and wide temperature bearable range, etc.
Product Dimensional Drawing (unit: mm)
Product Terminal Identification Drawing
DC current output ground(GND)
Voltage input terminal positive(U+) DC current output (Iz)
12
3 6 9
11
2 5 8
10
1 4 7
Voltage > 600V input terminal negative(U-)
Auxiliary power L
Voltage ≤ 600V input terminal negative(U-)
Auxiliary power N
Mianyang Weibo Electronic Co.,Ltd. 3
No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China
Tel: 86-0816-2971265 Fax: 86-016-2281934
www.wbsensor.com
[email protected] 4
Terminal definition table
1/4 U-
3 U+
10 L
11 N
8 Iz
7 GND
Key Technical Data:
1. Input: AC 0~10V…0~1000V;
2. Output: DC 4-20mA
3. frequency range: 25Hz~5kHz
4. Accuracy : 0.5%
5. Input Impedance (R): When Ux≥10V,Ri=Ux×1kΩ/V;
When Ux<10V,Ri=Ux×10kΩ/V;
6. Linear Range:0-120% of nominal input
7. Responding Time: 300ms
8. Over Load Capacity: 2 times of nominal input, continuous;
9. Maximum Load(Output voltage): 6V
10. static current: 8mA
11. Auxiliary Power: 165V~265Vac;100~ 370V dc;
12. Isolation Voltage(Input/output/power supply): 2500Vdc, for 1 minute
13. Output Ripple: <6mV
14. Drifting by Temperature: 3×10-4/℃
15. Ambient Temperature: -10℃~+50℃
16. Mounting : DIN Rail 35mm Mounting
Instruction of Installation and Use
1. The product has adopted structure compliance with EN50022; suitable for DIN rail
mounting NS35/7.5, NS35/15. Installation steps are as following (please reference to
dimensional drawing):
Step 1: Immobilize one side of product‘s mounting trough to the DIN mounting rail;
Step 2: Pull out the spring clasp;
Step 3: Place whole mounting trough to the DIN mounting rail properly;
Step 4: Release spring clasp to make sure the installation.
2. The product has calibrated before out of factory. After correctly wiring, it can be
powered and used immediately. But for further precise signal sampling, user needs to
warm-up the product for 3 minutes before use.
Mianyang Weibo Electronic Co.,Ltd. 4
No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China
Tel: 86-0816-2971265 Fax: 86-016-2281934
www.wbsensor.com
[email protected] 5
a) The auxiliary power requires isolation voltage≥2000VAC, DC current output ripple
<10mV, and multiple converters can share with one set auxiliary power together.
b) Output signal (Iz) is designed to follow the impedance load value of 250Ω; When
Resistance (R1 ) is less than 100Ω, the user must add output current circuit a power
reduced resistance load R0 to keep the summation of total impedance value is
between 100Ω~250Ω
R0
7
Transducer User system
IZ RL
8
3. Basic testing method for accuracy
(1) According to the terminal definition table to connect the testing circuit;
(2) The testing must to be done by under the following conditions;
Auxiliary power: 24V±1%,ripple≤5mV
Ambient temperature: 25℃±2℃
Relative humidity: RH(45~75)%
Accuracy for Signal Power Source instrument: 0.05
Auxiliary
Power
L N
+ 10 11
Signal Iz +
3 8
Power
Source
V1 Transducer 250Ω V2
1
-
7
GND -
(3) Warming up the transducer for 3 minutes
(4) Using output monitoring meter V1 to measuring the output of signal power
source instrument, set any input value which is within the measuring range of
the transducer Ir. (e.g. if input value is 100V, the output is 4-20Ma, the
expected output value Iz should be calculated as:
Iz = (20mA-4mA)×Ur/100V+4mA
(5) Using output monitoring meter V2 to measuring the output voltage V0 of the
transducer, the basic introduced errorγof the transducer should be calculated
Mianyang Weibo Electronic Co.,Ltd. 5
No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China
Tel: 86-0816-2971265 Fax: 86-016-2281934
www.wbsensor.com [email protected]
6
as:
γ= (Vo-Iz×250Ω)/[(20mA-4mA)×250Ω]×100
(6) Repeating (4) (5), if calculated absolute value is less than the given accuracy
value of the transducer, it shows the transducer’s accurate grade is qualified.
Caution:
1. Pay attention to the auxiliary power information, especially the auxiliary power grade,
and polarity, otherwise will damage the product.
2. Pay attention to the wire connection; wrong terminal connection will cause
malfunction of the product and even damage the product;
3. Don’t dismantle the product, and carry with care to avoiding bump and fall of the
product;
4. If the product has been using under the environment with strong magnetic field
interference, please pay attention to the shield of input wire, and the output signal wire
should be as short as possible. For product intensive installation, the space between
each product should not be smaller than 10mm.
5. Only use identified terminals.
6. There is no lightening strike prevention circuit design in this product. For out door and
hazardous environment using, please add protective alternatives.
7. This product uses fire prevent ABS crust, its temperature withstand is only limited as
+85℃, higher than this limitation will cause the product deformation. Please use and
store carefully.
Product Input-Output characteristic curve
Output (mA)
23.2
20
4 Input (%)
0 100 120
4mA~20mA Input-Output characteristic curve
Mianyang Weibo Electronic Co.,Ltd. 6
No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China
Tel: 86-0816-2971265 Fax: 86-016-2281934
www.wbsensor.com
[email protected]