Radio time synchronisation secondary transmitter
DHF V2 927241
The HF (869MHz) radio transmitter sends the time code that it receives from the master clock.
The 869 MHz radio waves go through building walls: the coverage is about 100 to 200 metres and depends on
the number, structure and thickness of the walls. The DHF wireless time distribution uses a secured digital
transmission to avoid interferences with other transmissions.
In case of complex installation or when the reception is difficult, a secondary transmitter allows the coverage area
to be increased up to 1.5 km.
Transmitter
Repeater
Specifications Transmission LED
(red)
Indoor or outdoor use. Mains presence LED
Power supply : 100-240 V 50-60 HZ
(green)
Nominal current : 20 mA
Electrical insulation : Class II
Operating temperature : -10°C to +50°C
Protection index: IP54 and IK 07.
This system is compliant with :
EN 60950 (2006).
EN 301-489-3 (V1.4.1).
EN 300-220-2 (V2.3.1).
EN 62311 (2008).
NFS 87-500-C.
See Declaration of conformity at :
http://www.bodet.fr/espace-clients/certificats.html
Power setting LEDs
INIT mod LED
(yellow)
(yellow)
Make sure that the main transmitter and the slave clocks are in
the “Init” mode. Verify that the secondary transmitter red LED is
Some clocks are not synchronised.
blinking regularly. Increase the transmitter power. See diagram
What (7A).
to do Transmission power set to the maximum, some clocks are still
not synchronised.
Add a repeater (See 2).
if … See to it that the secondary transmitter is paired to the proper
You are close to an existing wireless clock system.
main transmitter, see (5).
?
B.P. 1
49340 TRÉMENTINES
FRANCE
Tél. : 02 41 71 72 00
Fax : 02 41 71 72 01
www.bodet.fr
Ref.: 607176 A
Downloaded from www.Manualslib.com manuals search engine
Radio time synchronisation secondary transmitter
DHF V2 927241
Start up instructions
1 2
Transmitter
Repeater
Mount the repeater in the area covered
by the transmitter. Under no
circumstances the transmitter should be
directly mounted on a metallic surface. The DHF repeater V2 (ref.: 927241) enables to extend an area non
covered by the main DHF transmitter.
3 4 5
G The DHF repeater must be
paired with the DHF transmitter in order to
B work properly:
A - Check that the « Init » mode yellow LED blinks. If
not, set up again the repeater in « Initialization”
mode (part 6).
Status of the DHF repeater at the first start
up. - Set up the main transmitter in “Init” mode.
- Power DIP (D) in position MED (125W).
- Power setting LED (C) ON (125 mW) on, - Once the signal of the main transmitter is
transmitted, the « Init » mode yellow LED is OFF
Connect the 230V (A) and secure the - INIT mode yellow LED (E) blinks (waiting for
and the DHF transmission red LED is ON.
powercable with the tie-wrap (B). Apply the initialization of the main transmitter),
the power. - DHF transmission Red LED (G) OFF.
6 7a C Témoin
H 7b
E émission
F
D
Leds
Dips
00 10 01 11
OFF (0W) 25mW 125mW 500mW
In “initialisation” mode, the LED (E) is You can adapt the transmission power If some clocks are not synchronised, increase the
with two DIP switches (D). LEDs (C) allow transmission power.
on. To switch the repeater back in Init
you to check your setting. The DHF repeater has a buzzer (H). It can be
mode, short the two pins (F) for 3 activated from the master clock Sigma to help in
seconds. localizing the DHF repeater.
Downloaded from www.Manualslib.com manuals search engine